1
|
Williams WT, Lindley K, Liao H, Kamen L, Miller M, Hays A, Sailstad J. Development of a validated novel bead extraction method for the detection of anti-PEG antibodies in human serum. Bioanalysis 2025; 17:7-15. [PMID: 39696894 PMCID: PMC11749383 DOI: 10.1080/17576180.2024.2442198] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2024] [Accepted: 12/11/2024] [Indexed: 12/20/2024] Open
Abstract
AIMS Polyethylene glycol (PEG) is used in many applications including drug development. Due to exposure to environmental products, there is a high prevalence of preexisting anti-PEG antibodies in the global human population. The presence of anti-PEG antibodies is a concern for potentially reducing the efficacy of therapeutics after administration and represents a risk of safety events after exposure to PEGylated drug products. We developed and validated a creative and sensitive method for the detection of anti-PEG antibodies in human serum to support clinical programs for PEGylated drugs. METHODS In this method, biotin-PEG streptavidin beads were used to extract anti-PEG antibodies from human serum for analysis in an anti-PEG ELISA assay. The same serum sample was analyzed in an anti-drug antibody assay. RESULTS The anti-PEG antibody assay was validated with a screening cut point of 1.41 normalized signal, confirmatory cut point of 32.2% inhibition, sensitivity of 7.81 ng/mL and sufficient reproducibility, selectivity, and drug tolerance in accordance with the FDA 2019 Immunogenicity guidance. CONCLUSION This method of removal of anti-PEG antibodies enables the use of a single sample to detect anti-drug and anti-PEG antibodies to support drug development programs.
Collapse
|
2
|
Ballman KK, Peek VL, Sloan JH, Li J, Konrad RJ, Wen Y. Cross-Reactive Polyclonal Antibodies Raised Against GalNAc-Conjugated siRNA Recognize Mostly the GalNAc Moiety. AAPS J 2024; 26:41. [PMID: 38570436 DOI: 10.1208/s12248-024-00914-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Accepted: 03/19/2024] [Indexed: 04/05/2024] Open
Abstract
Small interfering RNA (siRNA) is gaining momentum as a therapeutic modality with six approved products. Since siRNA has the potential to elicit undesired immune responses in patients, immunogenicity assessment is required during clinical development by regulatory authorities. In this study, anti-siRNA polyclonal antibodies were generated through animal immunization. These cross-reactive polyclonal antibodies recognized mostly the N-acetylgalactosamine (GalNAc) moiety with a small fraction against sequence-independent epitopes. We demonstrate that the polyclonal antibodies can be utilized as immunogenicity assay positive controls for the same class of GalNAc-conjugated siRNAs. In addition, anti-GalNAc mAbs showed desired sensitivity and drug tolerance, supporting their use as alternative surrogate positive controls. These findings can guide positive control selection and immunogenicity assay development for GalNAc-conjugated siRNAs and other oligonucleotide therapeutics.
Collapse
Affiliation(s)
- Kimberly K Ballman
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, 46285, Indiana, USA
| | - Victoria L Peek
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, 46285, Indiana, USA
| | - John H Sloan
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, 46285, Indiana, USA
| | - Jingling Li
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, 46285, Indiana, USA
| | - Robert J Konrad
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, 46285, Indiana, USA
| | - Yi Wen
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, 46285, Indiana, USA.
| |
Collapse
|
3
|
Zhang L, Hodsdon ME, Pottanat T, Wang S, Konrad RJ, Seta N, Higgs RE. A systematic examination of anti-drug antibody titer estimation: Applied recommendations. J Immunol Methods 2023; 522:113569. [PMID: 37748729 DOI: 10.1016/j.jim.2023.113569] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 09/14/2023] [Accepted: 09/21/2023] [Indexed: 09/27/2023]
Abstract
Biologic drugs (therapeutic proteins or peptides) have become one of the most important therapeutic modalities over the past few decades. Drug-induced immunogenicity is a significant concern as it may affect safety, tolerability, and efficacy. With more sensitive and drug-tolerant screening assays in use today, reliable estimation of anti-drug-antibody (ADA) titer has become more important for understanding clinically relevant ADA levels. Titer is commonly defined as the dilution factor resulting in an assay signal equal to a pre-specified cut point factor. Given its influence on the resulting titer precision, the choice of a titer cut point factor warrants careful consideration. In this paper, we discuss the theoretical dilution model, investigate how titer variability depends on the cut point factor and propose a standardized cut point factor to increase precision of titer estimates. Additionally, we demonstrate that non-linear regression-based titer estimation provides both improved precision and implementation efficiency relative to commonly used estimation approaches.
Collapse
Affiliation(s)
- Lin Zhang
- Global Statistical Science, Eli Lilly and Company, 893 Delaware St, Indianapolis, IN 46225, United States of America
| | - Michael E Hodsdon
- Clinical Diagnostics Laboratory, Eli Lilly and Company, 893 Delaware St, Indianapolis, IN 46225, United States of America
| | - Thomas Pottanat
- Laboratory for Experimental Medicine, Eli Lilly and Company, 893 Delaware St, Indianapolis, IN 46225, United States of America
| | - Sihe Wang
- Laboratory for Experimental Medicine, Eli Lilly and Company, 893 Delaware St, Indianapolis, IN 46225, United States of America
| | - Robert John Konrad
- Laboratory for Experimental Medicine, Eli Lilly and Company, 893 Delaware St, Indianapolis, IN 46225, United States of America
| | - Nicholas Seta
- Clinical Laboratory Sciences, Eli Lilly and Company, 893 Delaware St, Indianapolis, IN 46225, United States of America
| | - Richard E Higgs
- Global Statistical Science, Eli Lilly and Company, 893 Delaware St, Indianapolis, IN 46225, United States of America.
| |
Collapse
|
4
|
Calderon B, Reynolds NA, Swearingen CA, Carter QL, Bivi N, Cramer JW, Alexander CL, Siegel RW, Konrad RJ. A Monovalent Fab Affinity-Capture and Elution Bridging Immunoassay Overcomes Rheumatoid Factor Interference while Accurately Detecting Antidrug Antibodies. J Appl Lab Med 2023; 8:896-908. [PMID: 37473444 DOI: 10.1093/jalm/jfad035] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2023] [Accepted: 04/19/2023] [Indexed: 07/22/2023]
Abstract
BACKGROUND Rheumatoid factor (RF) consists of autoantibodies that bind the fragment crystallizable (Fc) region of human immunoglobulin G (IgG) and present in sera of rheumatoid arthritis (RA) patients. Immunoassays to detect antidrug antibodies (ADA) in RA patient samples may experience interference due to RF binding and crosslinking Fc regions of the capture and detection antibody reagents. To overcome this interference, a novel Fab affinity-capture and elution (ACE)-bridging immunoassay (Fab ACE-Bridge) was developed with monovalent-recombinant Fab to avoid RF interference. METHODS ACE and ACE-Bridge assays were developed to detect ADA against a therapeutic monoclonal antibody using samples from healthy donors, psoriasis patients, and RA patients. The performance of these assays was compared to a novel Fab ACE-Bridge assay, in which monoclonal antibody was replaced with monovalent Fab. RESULTS High screening signals in the ACE and ACE-Bridge assays were detected in RA patient samples but not in samples from healthy donors or psoriasis patients. The high screening signals in RA samples did not inhibit to the expected extent in the confirmatory assay, a consistent feature of false-positive screening results. Further investigation revealed RF as the interferent affecting assay performance. Modification of the ACE-Bridge assay by using monovalent Fab eliminated RF interference while allowing for sensitive and drug-tolerant detection of authentic ADA. CONCLUSIONS RF interfered significantly in traditional ACE and ACE-Bridge assays. Implementation of a novel monovalent Fab ACE-Bridge assay overcame RF interference. The use of monovalent Fab is recommended for immunogenicity assays when assessing ADA in RA patient samples.
Collapse
Affiliation(s)
- Boris Calderon
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, United States
| | - Nichole A Reynolds
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, United States
| | - Craig A Swearingen
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, United States
| | - Quincy L Carter
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, United States
| | - Nicoletta Bivi
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, United States
| | - Jeff W Cramer
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, United States
| | - Courtney L Alexander
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, United States
| | - Robert W Siegel
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, United States
| | - Robert J Konrad
- Lilly Research Laboratories, Eli Lilly and Company, Indianapolis, IN 46285, United States
| |
Collapse
|
5
|
Sensitive assay design for detection of anti-drug antibodies to biotherapeutics that lack an immunoglobulin Fc domain. Sci Rep 2021; 11:15467. [PMID: 34326436 PMCID: PMC8322160 DOI: 10.1038/s41598-021-95055-x] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Accepted: 07/20/2021] [Indexed: 12/13/2022] Open
Abstract
Today the evaluation of unwanted immunogenicity is a key component in the clinical safety evaluation of new biotherapeutic drugs and macromolecular delivery strategies. However, the evolving structural complexity in contemporary biotherapeutics creates a need for on-going innovation in assay designs for reliable detection of anti-drug antibodies, especially for biotherapeutics that may not be well-suited for testing by a bridging assay. We, therefore, initiated systematic optimization of the direct binding assay to adapt it for routine use in regulatory-compliant assays of serum anti-drug antibodies. Accordingly, we first prepared a SULFO-TAG labeled conjugate of recombinant Protein-A/G to create a sensitive electrochemiluminescent secondary detection reagent with broad reactivity to antibodies across many species. Secondly, we evaluated candidate blocker-diluents to identify ones producing the highest signal-to-noise response ratios. Lastly, we introduced use of the ratio of signal responses in biotherapeutic-coated and uncoated wells as a data transformation strategy to identify biological outliers. This alternative data normalization approach improved normality, reduced skewness, and facilitated application of a parametric screening cut point. We believe the optimized direct binding assay design employing SULFO-TAG labeled Protein-A/G represents a useful analytical design for detecting serum ADA to biotherapeutics that lack an immunoglobulin Fc domain.
Collapse
|
6
|
Trastuzumab immunogenicity development in patients' sera and in laboratory animals. BMC Immunol 2021; 22:15. [PMID: 33607941 PMCID: PMC7893875 DOI: 10.1186/s12865-021-00405-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 02/03/2021] [Indexed: 12/11/2022] Open
Abstract
Background Immunogenicity is a major challenge in drug development and patient care. Clinicians and regulators are familiar with immunogenicity concerns of monoclonal antibody (mAb) therapeutics, growth factors and enzyme replacements. Although most small therapeutic molecules are unlikely to trigger undesirable immunogenic responses against themselves upon their administration, the biological therapeutic agents are likely to induce such kind of immunogenicity. This imparts a problem that has to be considered upon judging their risk–benefit ratio. In this article, we tested the immunogenicity developed in patients’ sera due to the use of trastuzumab and that developed in laboratory animals injected with this recombinant humanized IgG1 monoclonal antibody. Methods We studied trastuzumab immunogenicity by: I in vitro detection of anti-trastuzumab antibody (Ab) levels in patient’s serum samples withdrawn at different points during trastuzumab treatment course; I.1 using an Affinity Capture Elution (ACE) assay, the assay is both sensitive and highly tolerant to free drug; I.2 using MTT cytotoxicity method against MCF-7 cell line as confirmatory method used in sample showed high level of anti-trastuzumab Ab and to determine neutralizing activity of the anti-trastuzumab Ab. II in vivo immunogenicity testing of trastuzumab in lab animals. Results In vitro analysis of patients’ sera for antibodies developed against trastuzumab revealed that this monoclonal antibody has low immunogenicity since most samples showed low levels of anti-trastuzumab antibodies that decreased progressively along the treatment course. Only 1% of samples showed high levels of anti-trastuzumab antibodies which might affect treatment course. In vivo immunogenicity testing in mice showed also low immunogenicity of trastuzumab that could support the in vitro clinical assessment applied in our study. Conclusions The study gives an evidence for the low trastuzumab immunogenicity when assessed in Egyptian patients under treatment with this biological therapeutic agent. This supports its prescription and continuous use across the approved indications as biological therapeutic agent.
Collapse
|