Manon BDN, Ketani T, Bastard C, Rosi G, Lomani HA, Flouzat-Lachaniette CH, Dubory A, Haïat G. An Instrumented Hammer to Detect the Bone Transitions During an High Tibial Osteotomy: An Animal Study. J Biomech Eng 2025; 147:064502. [PMID: 40192639 DOI: 10.1115/1.4068372] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2024] [Indexed: 05/06/2025]
Abstract
High tibial osteotomy is a common procedure for knee osteoarthritis during which the surgeon partially opens the tibia and must stop impacting when cortical bone is reached by the osteotome. Surgeons rely on their proprioception and fluoroscopy to conduct the surgery. Our group has developed an instrumented hammer to assess the mechanical properties of the material surrounding the osteotome tip. The aim of this ex vivo study is to determine whether this hammer can be used to detect the transition from cortical to trabecular bone and vice versa. Osteotomies were performed until rupture in pig tibia using the instrumented hammer. An algorithm was developed to detect both transitions based on the relative variation of an indicator derived from the time variation of the force. The detection by the algorithm of both transitions was compared with the position of the osteotome measured with a video camera and with surgeon proprioception. The difference between the detection of the video and the algorithm (respectively, the video and the surgeon; the surgeon and the algorithm) is 1.0±1.5 impacts (respectively, 0.5±0.6 impacts; 1.4±1.8 impacts), for the detection of the transition from the cortical to trabecular bone. For the transition from the trabecular to cortical bone, the difference is 3.6±2.6 impacts (respectively, 3.9±2.4 impacts; 0.8±0.9 impacts), and the detection by the algorithm was always done before the sample rupture. This ex vivo study demonstrates that this method could prevent impacts leading to hinge rupture.
Collapse
Affiliation(s)
- Bas-Dit-Nugues Manon
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, 61 Avenue du Général de Gaulle, Créteil Cedex 94010, France
- CNRS Ingénierie
| | - Teddy Ketani
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, 61 Avenue du Général de Gaulle, Créteil Cedex 94010, France
- CNRS Ingénierie
| | - Claire Bastard
- Service de Chirurgie de la Main, Service d'Orthopédie et de Traumatologique, Hôpital Saint-Antoine, Sorbonne Université, 184, rue du Faubourg-Saint-Antoine, Paris 75012, France
- CNRS Ingénierie
| | - Giuseppe Rosi
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, 61 Avenue du Général de Gaulle, Créteil Cedex 94010, France
| | - Hugues Albini Lomani
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, 61 Avenue du Général de Gaulle, Créteil Cedex 94010, France
- CNRS Ingénierie
| | - Charles-Henri Flouzat-Lachaniette
- INSERM U955, IMRB, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, Créteil 94000, France; Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, Créteil 94000, France
| | - Arnaud Dubory
- INSERM U955, IMRB, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, Créteil 94000, France; Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, Créteil 94000, France
| | - Guillaume Haïat
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, 61 Avenue du Général de Gaulle, Créteil Cedex 94010, France
| |
Collapse
|
2
|
Bouffandeau A, Poudrel AS, Brossier C, Rosi G, Nguyen VH, Flouzat-Lachaniette CH, Meningaud JP, Haïat G. Assessment of the Mechanical Properties of Soft Tissue Phantoms Using Impact Analysis. SENSORS (BASEL, SWITZERLAND) 2025; 25:1344. [PMID: 40096164 PMCID: PMC11902684 DOI: 10.3390/s25051344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2024] [Revised: 02/06/2025] [Accepted: 02/20/2025] [Indexed: 03/19/2025]
Abstract
Skin physiopathological conditions have a strong influence on its biomechanical properties. However, it remains difficult to accurately assess the surface stiffness of soft tissues. The aim of this study was to evaluate the performances of an impact-based analysis method (IBAM) and to compare them with those of an existing digital palpation device, MyotonPro®. The IBAM is based on the impact of an instrumented hammer equipped with a force sensor on a cylindrical punch in contact with agar-based phantoms mimicking soft tissues. The indicator Δt is estimated by analyzing the force signal obtained from the instrumented hammer. Various phantom geometries, stiffnesses and structures (homogeneous and bilayer) were used to estimate the performances of both methods. Measurements show that the IBAM is sensitive to a volume of interest equivalent to a sphere approximately twice the punch diameter. The sensitivity of the IBAM to changes in Young's modulus is similar to that of dynamic mechanical analysis (DMA) and significantly better compared to MyotonPro. The axial (respectively, lateral) resolution is two (respectively, five) times lower with the IBAM than with MyotonPro. The present study paves the way for the development of a simple, quantitative and non-invasive method to measure skin biomechanical properties.
Collapse
Affiliation(s)
- Arthur Bouffandeau
- Laboratoire Modélisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France; (A.B.)
| | - Anne-Sophie Poudrel
- Laboratoire Modélisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France; (A.B.)
| | - Chloé Brossier
- Laboratoire Modélisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France; (A.B.)
| | - Giuseppe Rosi
- Laboratoire Modélisation et Simulation Multi Echelle, Université Paris Est Créteil, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France
| | - Vu-Hieu Nguyen
- Laboratoire Modélisation et Simulation Multi Echelle, Université Paris Est Créteil, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France
| | - Charles-Henri Flouzat-Lachaniette
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, Laboratoire IMRB INSERM U955—Université Paris—Est Créteil, 8 rue du Général Sarrail, 94010 Créteil, France;
| | - Jean-Paul Meningaud
- Service de Chirurgie Plastique, Reconstructrice, Esthétique et Maxillo-Faciale, Hôpital Henri Mondor AP-HP, Laboratoire IMRB INSERM U955—Université Paris—Est Créteil, 8 rue du Général Sarrail, 94010 Créteil, France
| | - Guillaume Haïat
- Laboratoire Modélisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du Général de Gaulle, 94010 Créteil, France; (A.B.)
| |
Collapse
|
3
|
Bastard C, Haiat G, Hernigou P. Revisiting two thousand hinge fractures in open wedge high tibial osteotomy with a fifty years review: the oscillating saw cannot replace the traditional "ear-hand" dialogue between osteotome and hammer to estimate the elastic modulus of bone. SICOT J 2025; 11:5. [PMID: 39835708 PMCID: PMC11748527 DOI: 10.1051/sicotj/2024060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/19/2024] [Accepted: 12/20/2024] [Indexed: 01/22/2025] Open
Abstract
BACKGROUND Hinge fracture on the lateral part of the tibia (LHF) is a common complication of medial Open Wedge High Tibial Osteotomy (OWHTO). Many factors have been described as risks for these fractures, but no study has compared an osteotome or an oscillating saw to prevent LHF following OWHTO. METHODS This "propensity-score-matched" (PSM) study was conducted from data obtained in the literature from 1974 to November 2024. A total of 10,368 knees with OWHTO were identified. After 1:1 matching based on correction amount, posterior slope change, surgeon's experience, the osteotome and oscillating groups comprised 2760 knees each. RESULTS Among the 5520 knees of the PSM population, the prevalence of LHF was 6.1% in the osteotome alone group (168 cases), and 22% in the oscillating saw group (607 cases). The osteotome group had a significant lower prevalence of hinge fracture than the oscillating saw group (OR, 0.23; 95% CI, 0.19 to 0.27; p < 0.0001) and a lower rate of clinically relevant hinge fractures with revision (OR, 0.34; 95% CI, 0.25 to 0.45; p < 0.001. DISCUSSION The osteotome may be an appropriate method for preventing hinge fractures following OWHTO.
Collapse
Affiliation(s)
- Claire Bastard
- Hôpital Saint-Antoine 184 Rue du Faubourg Saint-Antoine 75012 Paris France
| | - Guillaume Haiat
- CNRS, Université Gustave Eiffel, University Paris East (UPEC) 5 Bd Descartes 77420 Champs-sur-Marne France
| | - Philippe Hernigou
- Hospital Henri Mondor, University Paris East (UPEC) Avenue du Marechal de Lattre de Tassigny 94000 Creteil France
| |
Collapse
|
4
|
Petrucci M, La Mattina AA, Curreli C, Tassinari E, Viceconti M. A finite element model to simulate intraoperative fractures in cementless hip stem designs. Med Eng Phys 2025; 135:104274. [PMID: 39922645 DOI: 10.1016/j.medengphy.2024.104274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2024] [Revised: 11/11/2024] [Accepted: 12/01/2024] [Indexed: 02/10/2025]
Abstract
Intraoperative femur fractures are a complication of hip arthroplasty, strongly related to the cementless stem design; this kind of fracture is not always recognised during surgery, and revision surgery may be necessary. The present study aimed to simulate intraoperative crack propagation during stem implantation using subject-specific quasi-static finite element models. Eleven subject-specific finite element femur models were built starting from CT data, and the implant pose and size of a non-commercial cementless stem were identified. The model boundary conditions were set with a compressive load from 1000 N to 10 000 N, to simulate the surgeon's hammering, and element deactivation was used to model the crack propagation. Two damage quantifiers were analysed to identify a threshold value that would allow us to assess if a fracture occurred. A methodology to assess the primary stability of the stem during insertion was also proposed, based on a push-out test. Crack propagation up to the surface was obtained in six patients; in two cases there was no crack generation, while in three patients the crack did not reach the external surface. This study demonstrates the possibility to simulate the propagation of the fracture intraoperatively during hip replacement surgery and generate quantitative information about the bone damage using a virtual cohort of simulated patients with anatomical and physiological variability.
Collapse
Affiliation(s)
- Maila Petrucci
- Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy; Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Italy
| | | | - Cristina Curreli
- Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Enrico Tassinari
- Orthopaedic-Traumatology and Prosthetic surgery and revisions of hip and knee implants, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| | - Marco Viceconti
- Medical Technology Lab, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy; Department of Industrial Engineering, Alma Mater Studiorum - University of Bologna, Italy.
| |
Collapse
|
5
|
Bas Dit Nugues M, Lamassoure L, Rosi G, Flouzat-Lachaniette CH, Khonsari RH, Haiat G. An Instrumented Hammer to Detect the Rupture of the Pterygoid Plates. Ann Biomed Eng 2025; 53:59-70. [PMID: 39174762 PMCID: PMC11782435 DOI: 10.1007/s10439-024-03596-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2023] [Accepted: 07/29/2024] [Indexed: 08/24/2024]
Abstract
PURPOSE Craniofacial osteotomies involving pterygomaxillary disjunction are common procedures in maxillofacial surgery. Surgeons still rely on their proprioception to determine when to stop impacting the osteotome, which is important to avoid complications such as dental damage and bleeding. Our group has developed a technique consisting in using an instrumented hammer that can provide information on the mechanical properties of the tissue located around the osteotome tip. The aim of this study is to determine whether a mallet instrumented with a force sensor can be used to predict the crossing of the osteotome through the pterygoid plates. METHODS 31 osteotomies were carried out in 16 lamb skulls. For each impact, the force signal obtained was analysed using a dedicated signal processing technique. A prediction algorithm based on an SVM classifier and a cost matrix was applied to the database. RESULTS We showed that the device could always detect the crossing of the osteotome, sometimes before its occurrence. The prediction accuracy of the device was 94.7%. The method seemed to be sensitive to the thickness of the plate and to crack apparition and propagation. CONCLUSION These results pave the way for the development of a per-operative decision support system in maxillofacial surgery.
Collapse
Affiliation(s)
- Manon Bas Dit Nugues
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Leo Lamassoure
- APHP, Hôpital Henri-Mondor, Service de Chirurgie Orthopédique, 94010, Créteil, France
| | - Giuseppe Rosi
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, 94010, Créteil, France
| | - Charles Henri Flouzat-Lachaniette
- INSERM U955, IMRB Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, Université Paris-Est, CHU Paris 12, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France
| | - Roman Hossein Khonsari
- APHP, Hôpital Necker-Enfants Malades, Service de Chirurgie maxillo-faciale et chirurgie plastique, Laboratoire 'Forme et Croissance du Crâne', 75015, Paris, France
| | - Guillaume Haiat
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, 61, Avenue du Général de Gaulle, 94010, Créteil Cedex, France.
| |
Collapse
|
6
|
Poudrel AS, Bouffandeau A, Rosi G, Dubory A, Lachaniette CHF, Nguyen VH, Haiat G. 3-D finite element model of the impaction of a press-fitted femoral stem under various biomechanical environments. Comput Biol Med 2024; 174:108405. [PMID: 38613890 DOI: 10.1016/j.compbiomed.2024.108405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2023] [Revised: 03/04/2024] [Accepted: 04/01/2024] [Indexed: 04/15/2024]
Abstract
BACKGROUND Uncemented femoral stem insertion into the bone is achieved by applying successive impacts on an inserter tool called "ancillary". Impact analysis has shown to be a promising technique to monitor the implant insertion and to improve its primary stability. METHOD This study aims to provide a better understanding of the dynamic phenomena occurring between the hammer, the ancillary, the implant and the bone during femoral stem insertion, to validate the use of impact analyses for implant insertion monitoring. A dynamic 3-D finite element model of the femoral stem insertion via an impaction protocol is proposed. The influence of the trabecular bone Young's modulus (Et), the interference fit (IF), the friction coefficient at the bone-implant interface (μ) and the impact velocity (v0) on the implant insertion and on the impact force signal is evaluated. RESULTS For all configurations, a decrease of the time difference between the two first peaks of the impact force signal is observed throughout the femoral stem insertion, up to a threshold value of 0.23 ms. The number of impacts required to reach this value depends on Et, v0 and IF and varies between 3 and 8 for the set of parameters considered herein. The bone-implant contact ratio reached after ten impacts varies between 60% and 98%, increases as a function of v0 and decreases as a function of IF, μ and Et. CONCLUSION This study confirms the potential of an impact analyses-based method to monitor implant insertion and to retrieve bone-implant contact properties.
Collapse
Affiliation(s)
- Anne-Sophie Poudrel
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Arthur Bouffandeau
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Giuseppe Rosi
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010 Créteil, France
| | - Arnaud Dubory
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, Créteil, France
| | - Charles-Henri Flouzat Lachaniette
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, Créteil, France
| | - Vu-Hieu Nguyen
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010 Créteil, France
| | - Guillaume Haiat
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France.
| |
Collapse
|
7
|
Ahmed K, Blunn GW. A scoring system to evaluate stability of percutaneous osseointegrated implants for transfemoral amputation with validation in the ITAP clinical trial. Proc Inst Mech Eng H 2024; 238:412-422. [PMID: 38415608 DOI: 10.1177/09544119241231890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/29/2024]
Abstract
Percutaneous osseointegrated implants for individuals with lower limb amputation can increase mobility, reduce socket related pain, and improve quality of life. It would be useful to have an evaluation method to assess the interface between bone and implant. We assessed outpatient radiographs from the Intraosseous Transcutaneous Amputation Prosthesis clinical trial using an interface scoring system which summed and weighted equally measures of implant collar cortical ongrowth and radiolucency along the implant stem/bone interface. Radiographs from 12 participants with unilateral transfemoral amputations (10 males, 2 females, mean age = 43.2, SD = 7.4 years) in the clinical trial from cohort I (implanted in 2008/09) or cohort II (implanted in 2013/14) were collated (mean image span = 7.2, SD = 2.4 years), scale normalised, zoned, and measured in a repeatable way. Interface scores were calculated and then compared to clinical outcomes. Explanted participants received the lowest interface scores. A higher ratio of stem to residuum and shorter residuum's produced better interface scores and there was an association (weak correlation) between participants with thin cortices and the lowest interface scores. A tapered, cemented, non curved stem may provide advantageous fixation while stem alignment did not appear critical. In summary, the interface score successfully demonstrated a non-invasive evaluation of percutaneous osseointegrated implants interfaces when applied to the Intraosseous Transcutaneous Amputation Prosthesis clinical trial. The clinical significance of this work is to identify events leading to aseptic or septic implant removal and contribute to clinical guidelines for monitoring rehabilitation, design and surgical fixation choices.
Collapse
Affiliation(s)
- Kirstin Ahmed
- Center for Bionics and Pain Research, Mölndal, Sweden
- Division of Surgery and Interventional Science, University College London, Stanmore, UK
| | - Gordon William Blunn
- Division of Surgery and Interventional Science, University College London, Stanmore, UK
- School of Pharmacy and Biomedical Sciences, University of Portsmouth, Portsmouth, UK
| |
Collapse
|
8
|
Poudrel AS, Bouffandeau A, Demeet OL, Rosi G, Nguyen VH, Haiat G. Characterization of the concentration of agar-based soft tissue mimicking phantoms by impact analysis. J Mech Behav Biomed Mater 2024; 152:106465. [PMID: 38377641 DOI: 10.1016/j.jmbbm.2024.106465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2023] [Revised: 01/14/2024] [Accepted: 02/13/2024] [Indexed: 02/22/2024]
Abstract
In various medical fields, a change of soft tissue stiffness is associated with its physio-pathological evolution. While elastography is extensively employed to assess soft tissue stiffness in vivo, its application requires a complex and expensive technology. The aim of this study is to determine whether an easy-to-use method based on impact analysis can be employed to determine the concentration of agar-based soft tissue mimicking phantoms. Impact analysis was performed on soft tissue mimicking phantoms made of agar gel with a mass concentration ranging from 1% to 5%. An indicator Δt is derived from the temporal variation of the impact force signal between the hammer and a small beam in contact with the sample. The results show a non-linear decrease of Δt as a function of the agar concentration (and thus of the sample stiffness). The value of Δt provides an estimation of the agar concentration with an error of 0.11%. This sensitivity of the impact analysis based method to the agar concentration is of the same order of magnitude than results obtained with elastography techniques. This study opens new paths towards the development of impact analysis for a fast, easy and relatively inexpensive clinical evaluation of soft tissue elastic properties.
Collapse
Affiliation(s)
- Anne-Sophie Poudrel
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Arthur Bouffandeau
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Oriane Le Demeet
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France
| | - Giuseppe Rosi
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010 Créteil, France
| | - Vu-Hieu Nguyen
- Univ Paris Est Creteil, Univ Gustave Eiffel, CNRS, UMR 8208, MSME, F-94010 Créteil, France
| | - Guillaume Haiat
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-94010 Créteil, France.
| |
Collapse
|
9
|
Poudrel AS, Rosi G, Nguyen VH, Housset V, Flouzat-Lachaniette CH, Haiat G. Detection of periprosthetic fractures around the femoral stem by resonance frequency analysis: An in vitro study. Proc Inst Mech Eng H 2023:9544119231163632. [PMID: 36992542 DOI: 10.1177/09544119231163632] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/31/2023]
Abstract
Periprosthetic femoral bone fractures are frequent complications of Total Hip Arthroplasty (THA) and may occur during the insertion of uncemented Femoral Stems (FS), due to the nature of the press-fit fixation. Such fracture may lead to the surgical failure of the THA and require a revision surgery, which may have dramatic consequences. Therefore, an early detection of intra-operative fractures is important to avoid worsening the fracture and/or to enable a peroperative treatment. The aim of this in vitro study is to determine the sensitivity of a method based on resonance frequency analysis of the bone-stem-ancillary system for periprosthetic fractures detection. A periprosthetic fracture was artificially created close to the lesser-trochanter of 10 femoral bone mimicking phantoms. The bone-stem-ancillary resonance frequencies in the range (2-12) kHz were measured on an ancillary instrumented with piezoelectric sensors, which was fixed to the femoral stem. The measurements were repeated for different fracture lengths from 4 to 55 mm. The results show a decrease of the resonance frequencies due to the fracture occurrence and propagation. The frequency shift reached up to 170 Hz. The minimum fracture length that can be detected varies from 3.1±1.7 mm to 5.9±1.9 mm according to the mode and to the specimen. A significantly higher sensitivity (p = 0.011) was obtained for a resonance frequency around 10.6 kHz, corresponding to a mode vibrating in a plane perpendicular to the fracture. This study opens new paths toward the development of non-invasive vibration-based methods for intra-operative periprosthetic fractures detection.
Collapse
Affiliation(s)
- Anne-Sophie Poudrel
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-96010 Créteil
| | - Giuseppe Rosi
- Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-96010 Créteil, France
| | - Vu-Hieu Nguyen
- Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-96010 Créteil, France
| | - Victor Housset
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est Créteil, Créteil, France
- INSERM U955, IMRB, Université Paris-Est Créteil, Créteil, France
| | - Charles-Henri Flouzat-Lachaniette
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est Créteil, Créteil, France
- INSERM U955, IMRB, Université Paris-Est Créteil, Créteil, France
| | - Guillaume Haiat
- CNRS, Univ Paris Est Creteil, Univ Gustave Eiffel, UMR 8208, MSME, F-96010 Créteil
| |
Collapse
|
10
|
Bas dit Nugues M, Rosi G, Hériveaux Y, Haïat G. Using an Instrumented Hammer to Predict the Rupture of Bone Samples Subject to an Osteotomy. SENSORS (BASEL, SWITZERLAND) 2023; 23:2304. [PMID: 36850902 PMCID: PMC9965419 DOI: 10.3390/s23042304] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/22/2022] [Revised: 02/09/2023] [Accepted: 02/14/2023] [Indexed: 06/18/2023]
Abstract
Osteotomies are common procedures in maxillofacial and orthopedic surgery. The surgeons still rely on their proprioception to control the progression of the osteotome. Our group has developed an instrumented hammer that was shown to provide information on the biomechanical properties of the tissue located around the osteotome tip. The objective of this study is to determine if this approach may be used to predict the rupture of a bone sample thanks to an instrumented hammer equipped with a force sensor. For each impact, an indicator τ is extracted from the signal corresponding to the variation of the force as a function of time. A linear by part regression analysis is applied to the curve corresponding to the variation of τ as a function of the distance d between the tip of the osteotome and the end of the sample. The experiments were conducted with plywood and bovine trabecular bone samples. The results show that τ starts increasing when the value of d is lower than 2.6 mm on average, which therefore corresponds to a typical threshold detection distance between the osteotome tip and the sample end. These findings open new paths for the development of this instrumented surgical hammer.
Collapse
Affiliation(s)
- Manon Bas dit Nugues
- Laboratoire Modelisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du General de Gaulle, 94010 Creteil, France
| | - Giuseppe Rosi
- Laboratoire Modelisation et Simulation Multi Echelle, Universite Paris Est Creteil, MSME UMR 8208 CNRS, 61 Avenue du General de Gaulle, 94010 Creteil, France
| | - Yoann Hériveaux
- Laboratoire Modelisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du General de Gaulle, 94010 Creteil, France
| | - Guillaume Haïat
- Laboratoire Modelisation et Simulation Multi Echelle, Centre National de la Recherche Scientifique, MSME UMR 8208 CNRS, 61 Avenue du General de Gaulle, 94010 Creteil, France
| |
Collapse
|
11
|
Poudrel AS, Nguyen VH, Rosi G, Haiat G. Influence of the biomechanical environment on the femoral stem insertion and vibrational behavior: a 3-D finite element study. Biomech Model Mechanobiol 2022; 22:611-628. [PMID: 36542227 DOI: 10.1007/s10237-022-01667-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2022] [Accepted: 12/04/2022] [Indexed: 12/24/2022]
Abstract
The long-term success of cementless surgery strongly depends on the implant primary stability. The femoral stem initial fixation relies on multiple geometrical and material factors, but their influence on the biomechanical phenomena occurring during the implant insertion is still poorly understood, as they are difficult to quantify in vivo. The aim of the present study is to evaluate the relationship between the resonance frequencies of the bone-implant-ancillary system and the stability of the femoral stem under various biomechanical environments. The interference fit IF, the trabecular bone Young's modulus [Formula: see text] and the bone-implant contact friction coefficient [Formula: see text] are varied to investigate their influence on the implant insertion phenomena and on the system vibration behavior. The results exhibit for all the configurations, a nonlinear increase in the bone-implant contact throughout femoral stem insertion, until the proximal contact is reached. While the pull-out force increases with [Formula: see text], IF and [Formula: see text], the bone-implant contact ratio decreases, which shows that a compromise on the set of parameters could be found in order to achieve the largest bone-implant contact while maintaining sufficient pull-out force. The modal analysis on the range [2-7] kHz shows that the resonance frequencies of the bone-implant-ancillary system increase with the bone-implant contact ratio and the trabecular bone Young's modulus, with a sensitivity that varies over the modes. Both the pull-out forces and the vibration behavior are consistent with previous experimental studies. This study demonstrates the potential of using vibration methods to guide the surgeons for optimizing implant stability in various patients and surgical configurations.
Collapse
|
12
|
History of bone acoustic in fracture diagnosis: crepitus in antiquity; bone percussion with Auenbrugger; bone auscultation with Laennec and Lisfranc; monitoring cementless hip arthroplasty fixation with acoustic and sensor. INTERNATIONAL ORTHOPAEDICS 2022; 46:1657-1666. [PMID: 35451635 DOI: 10.1007/s00264-022-05397-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2022] [Accepted: 03/29/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE The problems posed by trauma, fractures, and dislocations have not changed in human history. The traumas of prehistoric persons were similar to those observed by Imhotep, Hippocrates, and Galen or, more recently, by Ambroise Paré, Watson Jones, and Böhler. And the current road traumas are probably no more severe than those caused by mammoths, the construction of the pyramids, or middle age wars. Diagnostic methods have evolved, and the advent of radiography has revolutionized the diagnosis of traumatology. Before discovering radiography, another physical phenomenon made it possible to help in the diagnosis of fractures. This physical phenomenon is acoustic. METHODS Curiously, no history of acoustics in fracture diagnosis has been published so far. This article proposes briefly reviewing the history and evolution of acoustics in orthopaedic surgery from antiquity to the present day. RESULTS Before the invention of radiography by Conrad Roentgen in 1895, the surgeons described crepitus as the most critical sign of fractures in antiquity. Surgeons remarked during the eighteenth and nineteenth century that bone was a good sound-conductor. Physicians improved first the diagnosis of fractures by using percussion established by Auenbrugger in 1755. The principle of chest mediate auscultation with a stethoscope was described by Laennec in 1818. Lisfranc used the stethoscope to amplify the crepitus sound of fractures. Surgeons also developed association of percussion and auscultation with a stethoscope to diagnose and reduce fracture. Recently, acoustic emission technology has seen a recent increase in applications to prevent femur fractures during cementless fixation. CONCLUSION The acoustic properties of bones were known to a prehistoric person who knew how to make flutes from animal or human bones. Surgeons used them for the diagnosis of fractures before radiography. Acoustic properties of bones currently remain a subject of research for the prevention of fractures.
Collapse
|
13
|
Influence of Artificial Soft Tissue on Intra-Operative Vibration Analysis Method for Primary Fixation Monitoring in Cementless Total Hip Arthroplasty. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12084027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Abstract
In cementless Total Hip Arthroplasty (THA), achieving high primary implant fixation is crucial for the long-term survivorship of the femoral stem. While orthopedic surgeons traditionally assess fixation based on their subjective judgement, novel vibration-analysis fixation-monitoring techniques show promising potential in providing the surgeon with objective and quantifiable fixation measurements. This study presents a dynamic response measurement protocol for implant endpoint insertion and evaluates this protocol in the presence of artificial soft tissue. After the artificial femur was prepared in accordance with the THA protocol, the implant was inserted and progressively hammered into the cavity. The Pearson Correlation Coefficient (PCC) and Frequency Response Assurance Criterion (FRAC) corresponding to each insertion hammer hit were derived from the Frequency Response Functions (FRF) corresponding to each insertion step. The protocol was repeated with the artificial femur submerged in artificial soft tissue to imitate the influence of anatomical soft tissue. The FRAC appeared overall more sensitive than the PCC. In the presence of the artificial soft tissue the technique yielded higher PCC and FRAC values earlier in the insertion process. The measurements with artificial soft tissue produced FRFs with fewer peaks, lower resonance frequencies, and overall higher damping factors. The soft tissue appears to limit the fixation-change detection capabilities of the system and a promising potential remedy to this limitation is suggested.
Collapse
|
14
|
Modal Analysis of the Ancillary During Femoral Stem Insertion: A Study on Bone Mimicking Phantoms. Ann Biomed Eng 2022; 50:16-28. [PMID: 34993695 DOI: 10.1007/s10439-021-02887-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 11/03/2021] [Indexed: 11/01/2022]
Abstract
The femoral stem primary stability achieved by the impaction of an ancillary during its insertion is an important factor of success in cementless surgery. However, surgeons still rely on their proprioception, making the process highly subjective. The use of Experimental Modal Analysis (EMA) without sensor nor probe fixation on the implant or on the bone is a promising non destructive approach to determine the femoral stem stability. The aim of this study is to investigate whether EMA performed directly on the ancillary could be used to monitor the femoral stem insertion into the bone. To do so, a cementless femoral stem was inserted into 10 bone phantoms of human femurs and EMA was carried out on the ancillary using a dedicated impact hammer for each insertion step. Two bending modes could be identified in the frequency range [400-8000] Hz for which the resonance frequency was shown to be sensitive to the insertion step and to the bone-implant interface properties. A significant correlation was obtained between the two modal frequencies and the implant insertion depth (R2 = 0.95 ± 0.04 and R2 = 0.94 ± 0.06). This study opens new paths towards the development of noninvasive vibration based evaluation methods to monitor cementless implant insertion.
Collapse
|
15
|
Klemt C, Bounajem G, Tirumala V, Xiong L, Padmanabha A, Kwon YM. Three-dimensional kinematic analysis of dislocation mechanism in dual mobility total hip arthroplasty constructs. J Orthop Res 2021; 39:1423-1432. [PMID: 32915465 DOI: 10.1002/jor.24855] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 08/25/2020] [Accepted: 09/08/2020] [Indexed: 02/04/2023]
Abstract
Dual mobility (DM) total hip arthroplasty (THA) is associated with reduced dislocation rates; however, the kinematic mechanism of dislocation in DM THA constructs is still not well understood. This study hypothesizes that the difference in kinematics between DM THA and conventional THA designs contributes to reduced dislocation rates of DM THA. In addition, this study aims to quantify and compare those kinematic parameters between DM THA and conventional THA using a validated dual fluoroscopy imaging system (DFIS) and finite element (FE) modelling. Fresh frozen cadavers were measured to compare the impingement-free range of motion and provocative subluxation kinematics among three THA constructs: (1) DM, (2) constrained liner (CS), and (3) 36 mm head diameter neutral liner (NL). The DFIS was used to measure the in vitro kinematics of the hip. Subject-specific FE models were developed to assess the horizontal dislocation distance and resistive torque at dislocation. The DM construct head exhibited increased provocative anterior and posterior subluxation range of motion before dislocation when compared to CS constructs (p = .05; p = .03), as well as NL constructs (p = .05). The DM THA showed a significantly larger posterior horizontal dislocation distance, as well as smaller resistive torque at dislocation, when compared to NL (p = .05; p = .03) and CS constructs (p = .04; p = .01). Our findings demonstrate there was increased provocative subluxation range of motion as well as normalized jump distance for the DM constructs compared to the NL and CS constructs, suggesting the DM THA may provide increased stability hip during at-risk functional hip positions.
Collapse
Affiliation(s)
- Christian Klemt
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Georges Bounajem
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Venkatsaiakhil Tirumala
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Liang Xiong
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Anand Padmanabha
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Young-Min Kwon
- Bioengineering Laboratory, Department of Orthopaedic Surgery, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
16
|
Goossens Q, Pastrav L, Roosen J, Mulier M, Desmet W, Vander Sloten J, Denis K. Acoustic analysis to monitor implant seating and early detect fractures in cementless THA: An in vivo study. J Orthop Res 2021; 39:1164-1173. [PMID: 32844506 DOI: 10.1002/jor.24837] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 07/01/2020] [Accepted: 08/18/2020] [Indexed: 02/04/2023]
Abstract
The initial stability of cementless total hip arthroplasty (THA) implants is obtained by an interference fit that allows osseointegration for a long term secondary stability of the implant. Yet, finding the insertion endpoint that corresponds to an appropriate initial stability is currently often based on a number of subjective experiences of the orthopedic surgeon, which can be challenging. In order to assist the orthopedic surgeons in their pursuit to find this optimal initial stability, this study aims to determine whether the analysis of sound that results from the implant insertion hammer blows can be used to objectively monitor the insertion process of cementless THA implants. An in vivo study was conducted. The experimental results revealed vibro-acoustic behavior sensitive to implant seating, related to the low frequency content of the response spectra. This sensitive low-frequency behavior was quantified by a set of specific vibro-acoustic features and metrics that reflected the power and similarity of the low-frequency response. These features and metrics allowed monitoring the implant seating and their convergence agreed well with the endpoint of insertion as determined by the orthopedic surgeon. Intraoperative fractures caused an abrupt and opposite change of the vibro-acoustic behavior prior to the notification of the fracture by the orthopedic surgeon. The observation of such an abrupt change in the vibro-acoustic behavior can be an important early warning for loss of implant stability. The presented vibro-acoustic measurement method shows potential to serve as a decision supporting source of information as it showed to reflect the implant seating.
Collapse
Affiliation(s)
- Quentin Goossens
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Leonard Pastrav
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Jorg Roosen
- Division of Orthopedics, University Hospital Leuven, Leuven, Belgium
| | - Michiel Mulier
- Division of Orthopedics, University Hospital Leuven, Leuven, Belgium
| | - Wim Desmet
- MSD Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Jos Vander Sloten
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| | - Kathleen Denis
- Biomechanics Section, Department of Mechanical Engineering, KU Leuven, Leuven, Belgium
| |
Collapse
|
17
|
Leuridan S, Goossens Q, Pastrav LC, Mulier M, Desmet W, Vander Sloten J, Denis K. Development of an Instrument to Assess the Stability of Cementless Femoral Implants Using Vibration Analysis During Total Hip Arthroplasty. IEEE JOURNAL OF TRANSLATIONAL ENGINEERING IN HEALTH AND MEDICINE 2021; 9:2500210. [PMID: 35103118 PMCID: PMC8791654 DOI: 10.1109/jtehm.2021.3128276] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2021] [Revised: 10/08/2021] [Accepted: 10/23/2021] [Indexed: 11/06/2022]
Abstract
Objective: The level of primary implant fixation in cementless total hip arthroplasty is a key factor for the longevity of the implant. Vibration-based methods show promise for providing quantitative information to help surgeons monitor implant fixation intraoperatively. A thorough understanding of what is driving these changes in vibrational behavior is important for further development and improvement of these methods. Additionally, an instrument must be designed to enable surgeons to leverage these methods. This study addresses both of these issues. Method: An augmented system approach was used to develop an instrument that improves the sensitivity of the vibrational method and enables the implementation of the necessary excitation and measurement equipment. The augmented system approach took into account the dynamics of the existing bone-implant system and its interaction with the added instrument. Results: Two instrument designs are proposed, accompanied by a convergence-based method to determine the insertion endpoint. The modal strain energy density distribution was shown to affect the vibrational sensitivity to contact changes in certain areas. Conclusion: The augmented system approach led to an instrument design that improved the sensitivity to changes in the proximal region of the combined bone-implant-instrument system. This fact was confirmed both in silico and in vitro. Clinical Impact: The presented method and instruments address practical intraoperative challenges and provide perspective to objectively support the surgeon’s decision-making process, which will ensure optimal patient treatment.
Collapse
Affiliation(s)
- Steven Leuridan
- KU LeuvenDepartment of Mechanical EngineeringBiomechanics Section 3000 Leuven Belgium
| | - Quentin Goossens
- KU LeuvenDepartment of Mechanical EngineeringBiomechanics Section 3000 Leuven Belgium
| | - Leonard Cezar Pastrav
- KU LeuvenDepartment of Mechanical EngineeringBiomechanics Section 3000 Leuven Belgium
| | - Michiel Mulier
- University Hospital LeuvenDepartment of Orthopaedics 3000 Leuven Belgium
| | - Wim Desmet
- KU LeuvenDepartment of Mechanical EngineeringLMSD Section 3000 Leuven Belgium
| | - Jos Vander Sloten
- KU LeuvenDepartment of Mechanical EngineeringBiomechanics Section 3000 Leuven Belgium
| | - Kathleen Denis
- KU LeuvenDepartment of Mechanical EngineeringBiomechanics Section 3000 Leuven Belgium
| |
Collapse
|
18
|
How do the geometries of the broach handles relate to the distribution of force and moments in a femoral model? Med Eng Phys 2020; 86:122-127. [PMID: 33261725 DOI: 10.1016/j.medengphy.2020.11.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2020] [Revised: 11/02/2020] [Accepted: 11/06/2020] [Indexed: 11/21/2022]
Abstract
The continuous improvement of minimally invasive hip endoprostheses surgery comes with a change in geometries of surgery instruments like the broach handles. Consequently, depending on the handles' curvature this results in a deviation between handle and femoral axis. Therefore, this study aimed to prove the influence of different handles' curvatures on the preparation of implant site and acting forces and moments in this process. Five femoral models attached to different handles (double-curved, single-curved, straight) were locked in a drop-weight device with standardize implantation forces and moments and five strokes were measured for each possible combination. Distribution of force and moment components was dependent on the handle's curvature, where the lowest variation from the standard force values was by the straight one (av:15.2% ± 0.5%) and the strongest discrepancies were exhibit by the double-curved one (av:54.3% ± 0.1%.). Moment values have also shown this trend with the lowest variation (12.4%-23.3%) by the straight one and the highest discrepancies (56,6%-90.9%) by the double-curved one. Results show that unguided axial impact introduces unwanted transverse forces and moments into the femur. Therefore, broach handles should be modified accordingly so that minimally invasive surgery remains feasible but unwanted forces or moments can still be compensated.
Collapse
|
19
|
Hériveaux Y, Nguyen VH, Biwa S, Haïat G. Analytical modeling of the interaction of an ultrasonic wave with a rough bone-implant interface. ULTRASONICS 2020; 108:106223. [PMID: 32771811 DOI: 10.1016/j.ultras.2020.106223] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Revised: 04/09/2020] [Accepted: 04/15/2020] [Indexed: 06/11/2023]
Abstract
Quantitative ultrasound can be used to characterize the evolution of the bone-implant interface (BII), which is a complex system due to the implant surface roughness and to partial contact between bone and the implant. The determination of the constitutive law of the BII would be of interest in the context of implant acoustical modeling in order to take into account the imperfect characteristics of the BII. The aim of the present study is to propose an analytical effective model describing the interaction between an ultrasonic wave and a rough BII. To do so, a spring model was considered to determine the equivalent stiffness K of the BII. The stiffness contributions related (i) to the partial contact between the bone and the implant and (ii) to the presence of soft tissues at the BII during the process of osseointegration were assessed independently. K was found to be comprised between 1013 and 1017 N/m3 depending on the roughness and osseointegration of the BII. Analytical values of the reflection and transmission coefficients at the BII were derived from values of K. A good agreement with numerical results obtained through finite element simulation was obtained. This model may be used for future finite element bone-implant models to replace the BII conditions.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 94010 Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, Créteil Cedex 94010, France
| | - Shiro Biwa
- Department of Aeronautics and Astronautics, Graduate School of Engineering, Kyoto University, Katsura, Nishikyo-ku, Kyoto 615-8540, Japan
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 94010 Créteil Cedex, France.
| |
Collapse
|
20
|
[Is the unlimited use of surgical instruments safe? : Discussion using the example of endoprosthetics]. DER ORTHOPADE 2020; 49:1049-1055. [PMID: 33112972 DOI: 10.1007/s00132-020-04022-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
As medical devices surgical instruments are important components when performing surgery. They can significantly influence the course and outcome of the surgery. Instruments are mechanically stressed in daily use and resterilized multiple times. The majority of manufacturer documentation for endoprostheses lacks specific information regarding tolerable instrument wear and the maximum number of applications for surgical instruments. So far, there are no mandatory algorithms for the necessity of checking and replacing surgical instruments. The risk of mechanical failure, surface damage and ultimately incidents is illustrated using endoprosthesis instruments as examples.
Collapse
|
21
|
Hubert A, Rosi G, Bosc R, Haiat G. Using an Impact Hammer to Estimate Elastic Modulus and Thickness of a Sample During an Osteotomy. J Biomech Eng 2020; 142:071009. [PMID: 32005998 DOI: 10.1115/1.4046200] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Indexed: 11/08/2022]
Abstract
Performing an osteotomy with a surgical mallet and an osteotome is a delicate intervention mostly based on the surgeon proprioception. It remains difficult to assess the properties of bone tissue being osteotomized. Mispositioning of the osteotome or too strong impacts may lead to bone fractures which may have dramatic consequences. The objective of this study is to determine whether an instrumented hammer may be used to retrieve information on the material properties around the osteotome tip. A hammer equipped with a piezo-electric force sensor was used to impact 100 samples of different composite materials and thicknesses. A model-based inversion technique was developed based on the analysis of two indicators derived from the analysis of the variation of the force as a function of time in order to (i) classify the samples depending on their material types, (ii) determine the materials stiffness, and (iii) estimate the samples thicknesses. The model resulting from the classification using support vector machines (SVM) learning techniques can efficiently predict the material of a new sample, with an estimated 89% prediction performance. A good agreement between the forward analytical model and the experimental data was obtained, leading to an average error lower than 10% in the samples thickness estimation. Based on these results, navigation and decision-support tools could be developed and allows surgeons to adapt their surgical strategy in a patient-specific manner.
Collapse
Affiliation(s)
- Alexis Hubert
- CNRS, Laboratoire Modélisation et Simulation Multi-Echelle, UMR CNRS 8208, 61 Avenue du Général de Gaulle, Créteil 94010, France
| | - Giuseppe Rosi
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 av du Général de Gaulle, Créteil 94010, France
| | - Romain Bosc
- INSERM U955, Team 16, Vaccine Research Institute (VRI), Faculté de Médecine, Créteil 94010, France; Université Paris Est, Plastic, Reconstructive, Aesthetic and Maxillofacial Surgery Department, Hopital Henri Mondor, 50, avenue du Maréchal de Lattre de Tassigny, Créteil 94000, France
| | - Guillaume Haiat
- CNRS, Laboratoire Modélisation et Simulation Multi-Echelle, UMR CNRS 8208, 61 Avenue du Général de Gaulle, Créteil 94010, France
| |
Collapse
|
22
|
Ex vivo estimation of cementless femoral stem stability using an instrumented hammer. Clin Biomech (Bristol, Avon) 2020; 76:105006. [PMID: 32388077 DOI: 10.1016/j.clinbiomech.2020.105006] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2019] [Revised: 04/10/2020] [Accepted: 04/14/2020] [Indexed: 02/07/2023]
Abstract
BACKGROUND The success of cementless hip arthroplasty depends on the primary stability of the femoral stem. It remains difficult to assess the optimal number of impacts to guarantee the femoral stem stability while avoiding bone fracture. The aim of this study is to validate a method using a hammer instrumented with a force sensor to monitor the insertion of femoral stem in bovine femoral samples. METHODS Different cementless femoral stem were impacted into five bovine femur samples, leading to 99 configurations. Three methods were used to quantify the insertion endpoint: the impact hammer, video motion tracking and the surgeon proprioception. For each configuration, the number of impacts performed by the surgeon until he felt a correct insertion was noted Nsurg. The insertion depth E was measured through video motion tracking, and the impact number Nvid corresponding to the end of the insertion was estimated. Two indicators, noted I and D, were determined from the analysis of the time variation of the force, and the impact number Nd corresponding to a threshold reached in D variation was estimated. FINDINGS The pullout force of the femoral stem was significantly correlated with I (R2 = 0.81). The values of Nsurg, Nvid and Nd were similar for all configurations. INTERPRETATION The results validate the use of the impact hammer to assess the primary stability of the femoral stem and the moment when the surgeon should stop the impaction procedure for an optimal insertion, which could lead to the development of a decision support system.
Collapse
|
23
|
Dubory A, Rosi G, Tijou A, Lomami HA, Flouzat-Lachaniette CH, Haïat G. A cadaveric validation of a method based on impact analysis to monitor the femoral stem insertion. J Mech Behav Biomed Mater 2019; 103:103535. [PMID: 31778909 DOI: 10.1016/j.jmbbm.2019.103535] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2018] [Revised: 10/17/2019] [Accepted: 11/12/2019] [Indexed: 10/25/2022]
Abstract
The success of cementless hip arthroplasty depends on the primary stability of the femoral stem (FS). It remains difficult to assess the optimal impaction energy to guarantee the FS stability while avoiding bone fracture. The aim of this study is to compare the results of a method based on the use of an instrumented hammer to determine the insertion endpoint of cementless FS in a cadaveric model with two other methods using i) the surgeon proprioception and ii) video motion tracking. Different FS were impacted in nine human cadaveric femurs. For each configuration, the number of impacts realized when the surgeon felt that the FS was correctly inserted was noted Nsurg. For each impact, the insertion depth E was measured and an indicator D was determined based on the time-variation of the force. The impact number Nvid (respectively Nd), corresponding to the end of the migration phase, was estimated analyzing the evolution of E (respectively D). The respective difference between Nsurg, Nvid and Nd was similar and lower than 3 for more than 85% of the configurations. The results allow a validation of the use of an impact hammer to assess the moment when the surgeon should stop the impaction, paving the way towards the development of a decision support system to assist the surgeon.
Collapse
Affiliation(s)
- Arnaud Dubory
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France; INSERM U955, IMRB Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France
| | - Giuseppe Rosi
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208, 61 Avenue du Général de Gaulle, Créteil, 94010, France
| | - Antoine Tijou
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208, 61 Avenue du Général de Gaulle, Créteil, 94010, France
| | - Hugues Albini Lomami
- INSERM U955, IMRB Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France
| | - Charles-Henri Flouzat-Lachaniette
- Service de Chirurgie Orthopédique et Traumatologique, Hôpital Henri Mondor AP-HP, CHU Paris 12, Université Paris-Est, 51 avenue du Maréchal de Lattre de Tassigny, 94000, Créteil, France
| | - Guillaume Haïat
- CNRS, Laboratoire de Modélisation et de Simulation Multi-Echelle, UMR CNRS 8208, 61 Avenue du Général de Gaulle, Créteil, 94010, France.
| |
Collapse
|
24
|
Hériveaux Y, Nguyen VH, Geiger D, Haïat G. Elastography of the bone-implant interface. Sci Rep 2019; 9:14163. [PMID: 31578440 PMCID: PMC6775155 DOI: 10.1038/s41598-019-50665-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2019] [Accepted: 09/17/2019] [Indexed: 01/04/2023] Open
Abstract
The stress distribution around endosseous implants is an important determinant of the surgical success. However, no method developed so far to determine the implant stability is sensitive to the loading conditions of the bone-implant interface (BII). The objective of this study is to investigate whether a quantitative ultrasound (QUS) technique may be used to retrieve information on compressive stresses applied to the BII. An acousto-mechanical device was conceived to compress 18 trabecular bovine bone samples onto coin-shaped implants and to measure the ultrasonic response of the BII during compression. The biomechanical behavior of the trabecular bone samples was modeled as Neo-Hookean. The reflection coefficient of the BII was shown to decrease as a function of the stress during the elastic compression of the trabecular bone samples and during the collapse of the trabecular network, with an average slope of −4.82 GPa−1. The results may be explained by an increase of the bone-implant contact ratio and by changes of bone structure occurring during compression. The sensitivity of the QUS response of the BII to compressive stresses opens new paths in the elaboration of patient specific decision support systems allowing surgeons to assess implant stability that should be developed in the future.
Collapse
Affiliation(s)
- Yoann Hériveaux
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Vu-Hieu Nguyen
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Didier Geiger
- Université Paris-Est, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, MSME UMR 8208 CNRS, 61 avenue du Général de Gaulle, 94010, Créteil Cedex, France.
| |
Collapse
|
25
|
Gao X, Fraulob M, Haïat G. Biomechanical behaviours of the bone-implant interface: a review. J R Soc Interface 2019; 16:20190259. [PMID: 31362615 PMCID: PMC6685012 DOI: 10.1098/rsif.2019.0259] [Citation(s) in RCA: 113] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 07/01/2019] [Indexed: 01/09/2023] Open
Abstract
In recent decades, cementless implants have been widely used in clinical practice to replace missing organs, to replace damaged or missing bone tissue or to restore joint functionality. However, there remain risks of failure which may have dramatic consequences. The success of an implant depends on its stability, which is determined by the biomechanical properties of the bone-implant interface (BII). The aim of this review article is to provide more insight on the current state of the art concerning the evolution of the biomechanical properties of the BII as a function of the implant's environment. The main characteristics of the BII and the determinants of implant stability are first introduced. Then, the different mechanical methods that have been employed to derive the macroscopic properties of the BII will be described. The experimental multi-modality approaches used to determine the microscopic biomechanical properties of periprosthetic newly formed bone tissue are also reviewed. Eventually, the influence of the implant's properties, in terms of both surface properties and biomaterials, is investigated. A better understanding of the phenomena occurring at the BII will lead to (i) medical devices that help surgeons to determine an implant's stability and (ii) an improvement in the quality of implants.
Collapse
Affiliation(s)
- Xing Gao
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
- Research Centre for Medical Robotics and Minimally Invasive Surgical Devices, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen 518055, People's Republic of China
| | - Manon Fraulob
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| | - Guillaume Haïat
- CNRS, Laboratoire Modélisation et Simulation Multi Echelle, UMR CNRS 8208, 61 avenue du Général de Gaulle, 94010 Créteil cedex, France
| |
Collapse
|