1
|
Calheiros-Lobo MJ, Carbas R, da Silva LFM, Pinho T. Impact of in vitro findings on clinical protocols for the adhesion of CAD-CAM blocks: A systematic integrative review and meta-analysis. J Prosthet Dent 2024; 131:1051-1070. [PMID: 36543700 DOI: 10.1016/j.prosdent.2022.08.024] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 08/25/2022] [Accepted: 08/26/2022] [Indexed: 12/23/2022]
Abstract
STATEMENT OF PROBLEM Computer-aided design and computer-aided manufacturing (CAD-CAM) blocks have evolved rapidly, making it difficult to establish the best clinical protocol for bonding a given block and whether an established protocol is appropriate for a newly introduced product. PURPOSE This integrative systematic review and meta-analysis aimed to clarify whether the clinician can select the most efficient adhesion protocols for CAD-CAM blocks by reading published in vitro studies and implementing them in daily practice. MATERIAL AND METHODS Based on the population, intervention, comparison, and outcome (PICO) strategy, 3 databases were searched for in vitro studies, randomized clinical trials, prospective or retrospective studies, and case reports from January 1, 2015, to July 31, 2021. A meta-analysis analyzed 28 studies to calculate the mean difference between best and worst protocols for each author and block with a random-effects model (α=.05). RESULTS From 508 relevant studies, 37 in vitro studies, 2 clinical studies, and 1 clinical report were selected for data extraction and qualitative analysis. Vita Enamic, IPS e.max CAD, LAVA Ultimate, and Vita Mark II blocks were the most studied, and RelyX Ultimate was the most used luting cement. The meta-analysis confirmed the null hypothesis that the evidence-based efficacy of clinical protocols to bond CAD-CAM blocks is still controversial (P<.05). CONCLUSIONS There are objective standards for individual in vitro tests, but the studies lack standardization. Some tested protocols were more efficient than others. Randomized clinical trials and well-documented clinical situations were almost nonexistent, making direct application of in vitro findings in clinical practice impossible.
Collapse
Affiliation(s)
- Maria João Calheiros-Lobo
- Clinical Professor, Department of Conservative Dentistry and Researcher, UNIPRO - Oral Pathology and Rehabilitation Research Unit, IUCS - CESPU, Gandra, Portugal.
| | - Ricardo Carbas
- Postdoctoral Researcher, INEGI - Institute of Science and Innovation in Mechanical and Industrial Engineering, University of Porto, Porto, Portugal
| | - Lucas F M da Silva
- Full Professor, Department of Mechanical Engineering, Faculty of Engineering, University of Porto, Porto, Portugal
| | - Teresa Pinho
- Full Professor and Researcher, UNIPRO - Oral Pathology and Rehabilitation Research Unit, IUCS - CESPU, Gandra, Portugal
| |
Collapse
|
2
|
Porto TS, Medeiros da Silva IG, de Freitas Vallerini B, Fernando de Goes M. Different surface treatment strategies on etchable CAD-CAM materials: Part II-Effect on the bond strength. J Prosthet Dent 2023; 130:770-779. [PMID: 35101273 DOI: 10.1016/j.prosdent.2021.10.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2021] [Revised: 10/20/2021] [Accepted: 10/21/2021] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Bonding to recently launched polymer-based computer-aided design and computer-aided manufacturing (CAD-CAM) materials has been challenging. Evidence regarding etching strategies for dual-phase CAD-CAM materials is sparse, but adequate bonding is crucial for the clinical success and longevity of a restoration. PURPOSE The purpose of this 2-part in vitro study was to evaluate and compare the effect of surface treatment strategies on the microshear bond strength and work of adhesion of polymer-based and ceramic materials. In addition, chemical elements present on the surface and the interface morphology after using those strategies were also assessed. MATERIALS AND METHODS Two CAD-CAM polymer and 1 CAD-CAM ceramic materials were selected for this in vitro study. The materials were subjected to different surface treatment strategies, including airborne-particle abrasion and the application of 9% hydrofluoric acid. Specimens were submitted to microshear bond strength before and after thermocycling, and the failure mode was classified. The work of adhesion was calculated based on the water-to-air surface tension of 72.8 mN.m-1 and the Young- Dupré equation. The surfaces were submitted to energy-dispersive X-ray spectroscopy, and the interfaces were analyzed using a scanning electron microscope. Data were subjected to 2-way ANOVA and the Tukey post hoc test (α=.05). RESULTS The highest microshear bond strength means were observed for the polymer-based materials when hydrofluoric acid or airborne-particle abrasion was applied. The 3 materials tested showed a decrease in microshear bond strength after thermocycling, except for applying airborne-particle abrasion to 1 of the polymer-based material tested. The ceramic material tested showed a high microshear bond strength with the application of airborne-particle abrasion and hydrofluoric acid combined. The work of adhesion varied across the materials and presented high means when hydrofluoric acid was used. CONCLUSIONS A combination of airborne-particle abrasion plus hydrofluoric acid should be considered for polymer-based or feldspathic ceramic CAD-CAM materials. In this in vitro study, both etching procedures combined produced higher bonding values for all materials tested.
Collapse
Affiliation(s)
- Thiago Soares Porto
- Assistant Professor, Division of Restorative and Prosthetic Dentistry, College of Dentistry, The Ohio State University, Columbus, Ohio.
| | - Italo Guimaraes Medeiros da Silva
- Researcher, Department of Macromolecular Science and Engineering, School of Engineering, Case Western Reserve University, Cleveland, Ohio
| | - Bruna de Freitas Vallerini
- PhD Candidate, Department of Dental Materials and Prosthodontics, Araraquara School of Dentistry, Sao Paulo State University (UNESP), Sao Paulo, Brazil
| | - Mario Fernando de Goes
- Professor, Department of Restorative Dentistry (Dental Materials Area), Piracicaba Dental School, University of Campinas (UNICAMP), Sao Paulo, Brazil
| |
Collapse
|
3
|
The Effect of Surface Treatments on Zirconia Bond Strength and Durability. J Funct Biomater 2023; 14:jfb14020089. [PMID: 36826888 PMCID: PMC9968119 DOI: 10.3390/jfb14020089] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Revised: 01/30/2023] [Accepted: 02/01/2023] [Indexed: 02/10/2023] Open
Abstract
To evaluate the effects of airborne particle abrasion (APA) combined with MDP-containing resin cement, a glass-ceramic spray deposition (GCSD) method on the shear bond strengths (SBSs) and durability of 3 mol% yttrium oxide-stabilized zirconia ceramic (3Y-TZP) compared with lithium disilicate glass ceramics (LDGC). 3Y-TZP disks were randomly treated as follows: for Group APA+MDP, 3Y-TZP was abrased using 50 μm Al2O3 particles under 0.1 Mpa and bonded with MDP-containing resin cement; for Group GCSD, 3Y-TZP was treated with the GCSD method, etched by 5% HF for 90 s, silanized and bonded with resin cement without MDP. Group LDGC was bonded as the Group GCSD. X-ray diffraction (XRD), attenuated total reflection Fourier transform infrared spectroscopy (ATR-FTIR), X-ray photoelectron spectroscopy (XPS), scanning electron microscopy (SEM) and energy dispersive X-ray detector (EDX) were used to analyze the surface chemical and micro-morphological changes of the ceramics before bonding. The bonded ceramic specimens were randomly divided into subgroups, and the SBSs were determined before and after 10,000 thermocycling. The SBSs were analyzed with a one-way ANOVA analysis. Failure modes were determined with optical microscopy and SEM. The XRD, ATR-FTIR and XPS results identified the formation of lithium disilicate and zirconium silicate on 3Y-TZP after GCSD. The SEM micrographs revealed that 3Y-TZP surfaces were roughened by APA, while 3Y-TZP with GCSD and LDGC surfaces could be etched by HF to be porous. The APA treatment combined with MDP-containing resin cement produced the high immediate zirconia shear bond strengths (SBSs: 37.41 ± 13.51 Mpa) that was similar to the SBSs of the LDGC (34.87 ± 11.02 Mpa, p > 0.05), but, after thermocycling, the former dramatically decreased (24.00 ± 6.86 Mpa, maximum reduction by 35.85%) and the latter exhibited the highest SBSs (30.72 ± 7.97 Mpa, minimum reduction by 11.9%). The 3Y-TZP with GCSD treatment displayed the lower zirconia SBSs before thermocycling (27.03 ± 9.76 Mpa, p < 0.05), but it was similar to the 3Y-TZP treated with APA and MDP containing resin cement after thermocycling (21.84 ± 7.03 vs. 24.00 ± 6.86 Mpa, p > 0.05). The APA combined with MDP-containing resin cement could achieve the high immediate zirconia SBSs of those of the LDGC, but it decreased significantly after thermocycling. The GCSD technique could yield the immediate zirconia SBSs similar to those of LDGC before thermocycling, and long-term zirconia SBSs were similar to those of 3Y-TZP treated with APA followed by MDP-containing resin cement after thermocycling. Hence, the GCSD technique could enrich zirconia surface treatments and is an alternative to zirconia surface pretreatment for 3Y-TZP bond durability.
Collapse
|
4
|
Seo SH, Kim JE, Nam NE, Moon HS. Effect of air abrasion, acid etching, and aging on the shear bond strength with resin cement to 3Y-TZP zirconia. J Mech Behav Biomed Mater 2022; 134:105348. [PMID: 35843114 DOI: 10.1016/j.jmbbm.2022.105348] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2022] [Revised: 06/20/2022] [Accepted: 06/28/2022] [Indexed: 11/25/2022]
Abstract
This study investigates the effect of acid etching treatment on the surface microstructure, surface roughness, and surface contact angle of zirconia and compares the effects of air abrasion, different etching times, and aging on the shear bond strength (SBS) of resin cement on the zirconia surface. 480 specimens (9 × 10 × 10 mm) were divided into as-sintered and air-abraded groups, and each group was further subdivided into six groups based on etching time (0, 3, 5, 10, 20, and 30 min). The etching solution comprised hydrofluoric acid 25%, sulfuric acid 16%, hydrogen peroxide, methyl alcohol, and purified water. The shear bond strength (SBS), scanning electron microscopy, surface roughness, contact angle, and failure mode were measured. The results indicated that the mean SBS values increased and decreased significantly when the etching times increased to 20 min and 30 min, respectively, in both groups. Further, SBS after aging was lower than that before aging in all groups. Sandblasting, etching time, and aging all showed significant effects (p < 0.001) in the three-way analysis of variance. In addition, the surface roughness increased and the contact angle decreased significantly with an increase in etching time. Thus, the acid-etching treatment induced significant changes on the zirconia surface and increased the SBS of the resin cement. The results of this in vitro study suggest that acid etching is a promising alternative for zirconia surface treatment.
Collapse
Affiliation(s)
- Song-Hee Seo
- Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea
| | - Jong-Eun Kim
- Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea
| | - Na-Eun Nam
- Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea
| | - Hong-Seok Moon
- Department of Prosthodontics, College of Dentistry, Yonsei University, Seoul, Republic of Korea.
| |
Collapse
|
5
|
Martins JD, Moura DMD, Lima CM, de Carvalho RLA, Leite FPP, Souza ROA. Surface Treatment and Cementation of Lithium Silicate Ceramics Containing ZrO2. Oper Dent 2022; 47:202-213. [DOI: 10.2341/20-156-l] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/10/2021] [Indexed: 11/23/2022]
Abstract
SUMMARY
Objective
To evaluate the effect of different surface treatments on the shear bond strength (SBS) of lithium silicate (LS) and lithium disilicate (LD) ceramics, after thermocycling.
Methods and Materials
For SBS test, 72 ceramic blocks (18×14×2 mm) were made (24 blocks from each ceramic material): VITA Suprinity (LSS), Celtra Duo (LSC), and Lithium disilicate (LD). The blocks were polished with sandpaper of increasing grit (#280, #400, #800, and #1200) and embedded in chemically activated acrylic resin. Afterwards, they were randomly divided into 12 groups (6 blocks per group) according to: “Ceramic” (LD, LSC, and LSS) and “Surface treatment” (HFS: hydrofluoric acid + silane; MEP: Monobond Etch & Prime/Ivoclar). From each treated surface ceramic block, four dual-curing resin cement cylinders (RelyX U200, 3M Oral Care) were prepared using a Tygon tube (Ø=3 mm and h=2 mm) and light cured for 40 seconds (1000 mW/cm2) (N=288/n=24). All specimens were submitted to thermocycling (10,000 cycles, 5°C and 55°C, 30 seconds) and then to SBS test at a crosshead speed of 1 mm/min using a 50-kgf load cell. Forty-five additional blocks were made for roughness and SEM analysis. Failure mode was also performed. The data (MPa) were statistically analyzed by oneway analysis of variance (ANOVA), Tukey test (5%), and Weibull analysis. The Ra was analyzed by Kruskal–Wallis and Dunn Test (5%). The other variables were analyzed qualitatively.
Results
ANOVA revealed that “surface treatment” was significant for all ceramic materials (p<0.05). The LD-HFS (18.66±3.49), LSC-HFS (16.81±2.62), and LSS-HFS (16.33±3.08) groups had significantly higher SBS than the LD-MEP (7.00±4.2), LSC-MEP (14.12±3.51), and LSS-MEP (13.87±2.52) groups. Complete adhesive failures at the cement– dentin interface were more frequent. Weibull modulus was superior for the LD-HFS (6.22), LSC-HFS (8.8), and LSS-HFS (7.4) groups.
Conclusion
HF followed by silanization is the most suitable surface treatment for the cementation of LS and LD glass ceramics.
Collapse
Affiliation(s)
- JD Martins
- Jordana Dias Martins, DDS, MSc, Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), São Pedro, Juiz de Fora, Brazil
| | - DMD Moura
- Dayanne Monielle Duarte Moura, DDS, MSc, PhD, professor, Department of Dentistry, State University of Rio Grande do Norte (UERN), Caicó/RN, Brazil
| | - CM Lima
- Camila Moreira Lima, DDS, MSc, PhD student, Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), São Pedro, Juiz de Fora, Brazil
| | - RLA de Carvalho
- Ronaldo Luís Almeida de Carvalho, MSc, PhD, professor, Department of Dentistry, School of Dentistry, Centro Universitário Braz Cubas, Mogi das Cruzes, Brazil
| | - FPP Leite
- Fabíola Pessôa Pereira Leite, DDS, MSc, PhD, professor Department of Restorative Dentistry, School of Dentistry, Federal University of Juiz de Fora (UFJF), São Pedro, Juiz de Fora, Brazil
| | - ROA Souza
- *Rodrigo Othávio Assunção e Souza, DDS, MSc, PhD, adjunct professor, Health Science Center, Department of Dentistry, School of Dentistry, Federal University of Rio Grande do Norte (UFRN), Lagoa Nova, Natal, Brazil
| |
Collapse
|
6
|
Surface Characterisation of Dental Resin Composites Related to Conditioning and Finishing. Polymers (Basel) 2021; 13:polym13234236. [PMID: 34883740 PMCID: PMC8659525 DOI: 10.3390/polym13234236] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 11/29/2021] [Accepted: 11/30/2021] [Indexed: 11/16/2022] Open
Abstract
Due to the little information related to surface processing and conditioning of resin matrix ceramic materials previous glazing, the main purpose of this in vitro study was to investigate the effect of different surface treatments on the surface morphology of different resin composite materials. Five types of resin composite CAD-CAM materials: a resin composite ceramic Vita Enamic (E) and four types of nanoparticle-filled resins, like Lava Ultimate (L), Cerasmart (C), Shofu HC (S), Hyramic (H) were taken into consideration. Specimens received the following surface treatment protocols: conventional polishing [p], polishing and glazing [pg], conditioning with CoJet [c], conditioning with CoJet and glazing [cg], sandblasting [s], sandblasting and glazing [sg], etching [e], etching and glazing [eg]. Surface roughness was analyzed for all samples and nanosurface topographic characterization was made by Atomic Force Microscopy. The highest roughness was registered for sandblasted surfaces [s], followed by tribochemical silica airborne particle abrasion [c], and etching [e]. A very strong correlated conditioning behavior of resin nanoceramic materials, like L, C and S samples was found. The microroughness decreased thus [s] > [c] > [e]. These are moderate correlated with H, and are moderate negative correlated to E, where e is more efficient. Three-dimensional images indicated visible grain boundaries after conditioning, for all materials. After polishing and glazing, surfaces became smoother. For all tested conditioning and finishing methods, surface roughness values were within clinically acceptable limits. Finishing by polishing was proved to be a good choice for all materials taken into consideration, polishing and glazing likewise, excepting Hyramic. For Enamic and Shofu HC sandblasting or tribochemical conditioning and glazing and for Hyramic polishing and glazing are not the best options, related to nanoroughness values. Referring to the nanosurface topography, for Enamic, Cerasmart and Hyramic, glazing would be the method of choice, associated with the adequate conditioning method for each material.
Collapse
|
7
|
Sarahneh O, Günal-Abduljalil B. The effect of silane and universal adhesives on the micro-shear bond strength of current resin-matrix ceramics. J Adv Prosthodont 2021; 13:292-303. [PMID: 34777719 PMCID: PMC8558573 DOI: 10.4047/jap.2021.13.5.292] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2021] [Revised: 09/24/2021] [Accepted: 10/18/2021] [Indexed: 11/21/2022] Open
Abstract
PURPOSE The aim of this in vitro study was to evaluate the effect of silane and universal adhesive applications on the micro-shear bond strength (µSBS) of different resin-matrix ceramics (RMCs). MATERIALS AND METHODS A total of 120 slides (14 × 12 × 1 mm) were produced from 5 different RMC materials (GC Cerasmart [GC]; Brilliant Crios [BC]; Grandio blocs [GB]; Katana Avencia [KA]; and KZR-CAD HR 2 [KZR]) and sandblasted using 50 µm Al2O3 particles. Each RMC material was divided into six groups according to the surface conditioning (SC) method as follows: control (G1), silane primer (G2), silane-free universal adhesive (G3), silane-containing universal adhesive (G4), silane primer and silane-free universal adhesive (G5), and silane primer and silane-containing universal adhesive (G6). Three cylindric specimens made from resin cement (Bifix QM) were polymerized over the treated surface of each slide (n = 12). After thermal cycling (10000 cycles, 5 – 55℃), µSBS test was performed and failure types were evaluated using a stereomicroscope. Data were analyzed using 2-way ANOVA and Tukey tests (α = .05). RESULTS µSBS values of specimens were significantly affected by the RMC type and SC protocols (P < .001) except the interaction (P = .119). Except for G2, all SC protocols showed a significant increase in µSBS values (P < .05). For all RMCs, the highest µSBS values were obtained in G4 and G6 groups. CONCLUSION Only silane application did not affect the µSBS values regardless of the RMC type. Moreover, the application of a separate silane in addition to the universal adhesives did not improve the µSBS values. Silane-containing universal adhesive was found to be the best conditioning method for RMCs.
Collapse
Affiliation(s)
- Omar Sarahneh
- Department of Prosthodontics, Faculty of Dentistry, Near East University, Nicosia, Turkey
| | - Burcu Günal-Abduljalil
- Department of Prosthodontics, Faculty of Dentistry, Near East University, Nicosia, Turkey
| |
Collapse
|
8
|
Changes in Crystal Phase, Morphology, and Flexural Strength of As-Sintered Translucent Monolithic Zirconia Ceramic Modified by Femtosecond Laser. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11156925] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Conventional bonding technology suitable for silica-based ceramics is not applicable to zirconia, due to its polycrystalline phase composition, chemical stability, and acid corrosion resistance. The development of an effective treatment to improve its surface roughness and mechanical properties remains an unresolved problem. Therefore, to solve this problem, this in vitro study evaluated the changes in surface morphology and flexural strength of translucent monolithic zirconia surfaces treated with femtosecond laser technology. As-sintered translucent zirconia specimens were subjected to airborne particle abrasion and femtosecond laser treatments, while control group specimens received no treatment. After treatment, the roughness and morphology of the treated zirconia surfaces were examined. The flexural strength and X-ray diffraction of the treated specimens were measured and analyzed. Statistical inferential analysis included one-way analysis of variance at a set significance level of 5%. The surface roughness after femtosecond laser treatment was significantly improved when compared with the control group and the group that received the airborne particle abrasion treatment (p < 0.05). In comparison with the airborne particle abrasion group, the flexural strength of the group that received the femtosecond laser treatment was significantly improved (p < 0.05). The femtosecond laser approach using appropriate parameters enhanced the roughness of the zirconia without reducing its flexural strength; therefore, this approach offers potential for the treatment of zirconia surfaces.
Collapse
|
9
|
Abouelleil H, Colon P, Jeannin C, Goujat A, Attik N, Laforest L, Gauthier R, Grosgogeat B. Impact of the Microstructure of CAD/CAM Blocks on the Bonding Strength and the Bonded Interface. J Prosthodont 2021; 31:72-78. [PMID: 33835621 DOI: 10.1111/jopr.13361] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 03/31/2021] [Indexed: 11/29/2022] Open
Abstract
PURPOSE To investigate the relationship between the microstructure of CAD/CAM blocks and the quality of adhesion as function of the surface treatment and resin cement type. MATERIALS AND METHODS Two nano-ceramic composite resin CAD/CAM blocks, Lava Ultimate (LU) and Cerasmart (CS), and two Leucite-reinforced glass ceramic CAD/CAM IPS blocks, Empress® CAD (EM) and InitialTM LRF (IR), received either Hydrofluoric acid (HF) or sandblasting (SB) surface treatments. The blocks were then luted using two dual-cure resin cements, LinkForce (LF) and Multilink Automix (ML) with their corresponding silanes, resulting in 16 study groups. The luted blocks were then thermal-cycling (TC) for 5000 cycles and subjected to a microtensile bond strength (μTBS) test. Scanning electron microscopy (SEM) micrographs of the treated surfaces were analyzed using ImageJ software and XRD analyses were performed for the two ceramic blocks. The data obtained were submitted to Games-Howell post-hoc nonparametric test to compare combinations of groups or treatments and a linear mixed-effects model for the factors surface treatment, block type, and resin cement, together with their first-degree interactions (α = 0.05). RESULTS The lowest mean μTBS values were obtained with LU-HF, whereas the highest mean μTBS values were obtained with CS regardless of resin cement type and surface treatment method. IR-HF mean μTBS were significantly higher than IR-SB, EM-SB, and EM-HF. Analysis using ImageJ software demonstrated significant differences in the density and pore size after HF surface treatment. CONCLUSIONS The specific microstructure of each block material within the same family group impacted the micromechanical retention and the bonded interface strength.
Collapse
Affiliation(s)
- Hazem Abouelleil
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France
| | - Pierre Colon
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Département d'Odontologie Conservatrice - Endodontie. Université de Paris, Faculté dentaire, Hôpital Rothschild, Assistance Publique-Hôpitaux de Paris, France
| | - Christophe Jeannin
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France.,Hospices Civils de Lyon, Service d'0dontologie, Lyon, France
| | - Alexis Goujat
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France.,Hospices Civils de Lyon, Service d'0dontologie, Lyon, France
| | - Nina Attik
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France
| | - Laurent Laforest
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France
| | - Remy Gauthier
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France
| | - Brigitte Grosgogeat
- Univ Lyon - Claude Bernard Lyon 1, UMR CNRS 5615, Laboratoire des Multimatériaux et Interfaces, Villeurbanne, France.,Univ Lyon, Université Claude Bernard Lyon 1, Faculté d'Odontologie, Lyon, France.,Hospices Civils de Lyon, Service d'0dontologie, Lyon, France
| |
Collapse
|
10
|
Which surface treatment promotes higher bond strength for the repair of resin nanoceramics and polymer-infiltrated ceramics? A systematic review and meta-analysis. J Prosthet Dent 2021; 128:139-149. [PMID: 33573835 DOI: 10.1016/j.prosdent.2020.06.009] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 06/13/2020] [Accepted: 06/15/2020] [Indexed: 01/22/2023]
Abstract
STATEMENT OF PROBLEM Which surface treatment provides the optimal bond strength (BS) for the repair of resin nanoceramics (RNCs) and polymer-infiltrated ceramics (PICs) is unclear. PURPOSE The purpose of this systematic review and meta-analysis of in vitro studies was to determine the best surface treatment protocols for the repair of PICs and RNCs. MATERIAL AND METHODS The PubMed, Scopus, and Web of Science electronic databases were searched to select in vitro studies in English up to March 2020. Studies with fewer than 5 specimens, those that did not evaluate the BS of PICs or RNCs, and those with aging for fewer than 30 days and 5000 cycles were excluded. Data sets were extracted, and the mean differences were analyzed by using a systematic review software program. RESULTS Among 284 potentially eligible studies, 21 were selected for full-text analysis, and 9 were included in the systematic review, of which 6 were used in the meta-analysis. The meta-analyses were performed for each treatment surface versus their respective control group and their combinations according to material: RNCs and PICs. For RNCs, airborne-particle abrasion with aluminum oxide (Al2O3) treatment was statistically higher than tribochemical silica airborne-particle abrasion (CoJet) (P=.02, I2=90%) and that in the hydrofluoric acid (HF) (P<.001, I2=0%) groups and was statistically similar to diamond rotary instrument grinding (P=.40, I2=54%). For PICs, the treatment with hydrofluoric acid (HF) was statistically significantly higher than with CoJet (P=.03, I2=62%) and airborne-particle abrasion with Al2O3 (P<.001, I2=98%). CONCLUSIONS The best surface treatment protocol for repair varied according to the restorative material. HF followed by silanization is suggested for PICs, and airborne-particle abrasion with Al2O3 or preparation with a diamond rotary instrument for RNCs.
Collapse
|
11
|
OĞUZ Eİ, ÇİÇEKCİ G. Influence of different repair protocols and artificial aging on bond strength of composite to a CAD/CAM polymer-infiltrated ceramic. CUMHURIYET DENTAL JOURNAL 2020. [DOI: 10.7126/cumudj.802118] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
|
12
|
Sismanoglu S, Yildirim-Bilmez Z, Erten-Taysi A, Ercal P. Influence of different surface treatments and universal adhesives on the repair of CAD-CAM composite resins: An in vitro study. J Prosthet Dent 2020; 124:238.e1-238.e9. [PMID: 32376031 DOI: 10.1016/j.prosdent.2020.02.029] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2020] [Revised: 02/17/2020] [Accepted: 02/17/2020] [Indexed: 11/29/2022]
Abstract
STATEMENT OF PROBLEM The repairability of computer-aided design and computer-aided manufacturing (CAD-CAM) composite resins might be adversely affected by the high degree of matrix polymerization that occurs during their manufacturing process. However, information on their repairability is lacking. PURPOSE The purpose of this in vitro study was to evaluate the microtensile bond strength of CAD-CAM composite resins subjected to simulated repair procedures by using varying surface treatments and universal adhesives. MATERIAL AND METHODS Four different CAD-CAM blocks (Brilliant Crios, Lava Ultimate, Shofu Block HC, and Vita Enamic) were thermocycled (5000 times, 5/55 °C) and divided into 4 groups according to the surface treatment: control, 9% hydrofluoric acid etching, aluminum oxide airborne-particle abrasion, and tribochemical silica airborne-particle abrasion. After surface treatments, the surface roughness was measured with a nanoindenter and further examined with scanning electron microscopy. After the application of 3 different universal adhesives (Clearfil Universal Bond, Prime&Bond Universal, and Single Bond Universal), the specimens were subjected to a simulated repair process with composite resin. Bonded specimens were cut into 1 mm2 beams, and microtensile bond strength values were determined until failure at a crosshead speed of 0.5 mm/min. The bond strength data were analyzed with 3-way analysis of variance, and surface roughness data were analyzed with 2-way analysis of variance tests. Pairwise analyses were performed with the Tukey test (α=.05). RESULTS All surface treatments effectively improved repair microtensile bond strength values compared with the control (P<.05). Aluminum oxide airborne-particle abrasion had similar mean bond strength values compared with tribochemical silica airborne-particle abrasion (P>.05). Among the CAD-CAM blocks treated with hydrofluoric acid etching, Vita Enamic had the highest mean bond strength values. The highest mean microtensile bond strength repair values with the highest cohesive failure rates were found with the silane-containing universal adhesive (Single Bond Universal). CONCLUSIONS Surface treatment with aluminum oxide airborne-particle abrasion and tribochemical silica airborne-particle abrasion produced successful repair results for aged resin nanoceramics, whereas hydrofluoric acid etching can be used for aged hybrid ceramic repair. Silane-containing universal adhesive reported increased bond strength. Application of universal adhesive after surface treatment is recommended to increase repair strength.
Collapse
Affiliation(s)
- Soner Sismanoglu
- Assistant Professor, Department of Restorative Dentistry, School of Dentistry, University of Altinbas, Istanbul, Turkey.
| | - Zuhal Yildirim-Bilmez
- Assistant Professor, Department of Restorative Dentistry, School of Dentistry, University of Hatay Mustafa Kemal, Hatay, Turkey
| | - Aysegul Erten-Taysi
- Assistant Professor, Department of Oral and Maxillofacial Surgery, School of Dentistry, University of Altinbas, Istanbul, Turkey
| | - Pınar Ercal
- Assistant Professor, Department of Oral and Maxillofacial Surgery, School of Dentistry, University of Altinbas, Istanbul, Turkey
| |
Collapse
|
13
|
Effects of hydrothermal aging, thermal cycling, and water storage on the mechanical properties of a machinable resin-based composite containing nano-zirconia fillers. J Mech Behav Biomed Mater 2020; 102:103522. [DOI: 10.1016/j.jmbbm.2019.103522] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 11/01/2019] [Accepted: 11/04/2019] [Indexed: 02/04/2023]
|