1
|
McPeak JE, Segantini M, Marcozzi G, Dona I, Künstner S, Chu A, Kern M, Poncelet M, Driesschaert B, Anders J, Lips K. Operando detection of dissolved oxygen in fluid solution using a submersible rapid scan EPR on a chip dipstick sensor. Sci Rep 2025; 15:9872. [PMID: 40119031 PMCID: PMC11928686 DOI: 10.1038/s41598-025-93591-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2024] [Accepted: 03/07/2025] [Indexed: 03/24/2025] Open
Abstract
Electron paramagnetic resonance (EPR) is an accurate and efficient technique to probe unpaired electrons in many applications across materials science, chemistry, and biology. Dynamic processes are investigated using EPR; however, these applications are limited by the use of resonator-based spectrometers such that the entire process must be confined to the resonator. The EPR-on-a-chip (EPRoC) device circumvents this limitation by integrating the entire EPR spectrometer into a single microchip. In this approach, the coil of a voltage-controlled oscillator (VCO) is used as the microwave source and detector simultaneously, operating under a protective coating such that the device may be placed in the sample solution directly. Additionally, improvements in sensitivity via rapid scan EPR (RS-EPR/RS-EPRoC) increase the accessible applications where SNR per measurement time is the fundamental limit. The herein reported device combines a dipstick EPRoC sensor with the enhanced sensitivity of frequency-swept frequency modulated rapid scan to measure triarylmethyl (trityl, Ox071) oxygen-sensitive probes dissolved in aqueous solutions. EPR spectra of Ox071 solutions were recorded using the RS-EPRoC sensor while varying the oxygen concentration of the solution between normal atmosphere and after purging the solution with nitrogen gas. We demonstrate that EPRoC may be employed to monitor dissolved oxygen in fluid solution in an online fashion.
Collapse
Affiliation(s)
- Joseph E McPeak
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Berlin, Germany.
- Department of Chemistry, Novo Nordisk Foundation Pulse EPR Center, University of Copenhagen, Copenhagen, Denmark.
| | - Michele Segantini
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Berlin, Germany
| | - Gianluca Marcozzi
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Berlin, Germany
| | - Irene Dona
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Berlin, Germany
| | - Silvio Künstner
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Berlin, Germany
| | - Anh Chu
- Institute of Smart Sensors, Universität Stuttgart, Stuttgart, Germany
| | - Michal Kern
- Institute of Smart Sensors, Universität Stuttgart, Stuttgart, Germany
| | - Martin Poncelet
- Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, Morgantown, WV, USA
- In Vivo Multifunctional Magnetic Resonance Center, Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV, USA
| | - Benoit Driesschaert
- Department of Pharmaceutical Sciences, School of Pharmacy, West Virginia University, Morgantown, WV, USA
- In Vivo Multifunctional Magnetic Resonance Center, Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV, USA
| | - Jens Anders
- Institute of Smart Sensors, Universität Stuttgart, Stuttgart, Germany
- Center for Integrated Quantum Science and Technology (IQST), Stuttgart and Ulm, Germany
| | - Klaus Lips
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Berlin, Germany
- Berlin Joint EPR Laboratory, Fachbereich Physik, Freie Universität Berlin, Berlin, Germany
| |
Collapse
|
2
|
Price BD, Sojka A, Maity S, Chavez IM, Starck M, Wilson MZ, Han S, Sherwin MS. Field-domain rapid-scan EPR at 240GHz for studies of protein functional dynamics at room temperature. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2024; 366:107744. [PMID: 39096714 DOI: 10.1016/j.jmr.2024.107744] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/12/2024] [Revised: 07/22/2024] [Accepted: 07/24/2024] [Indexed: 08/05/2024]
Abstract
We present field-domain rapid-scan (RS) electron paramagnetic resonance (EPR) at 8.6T and 240GHz. To enable this technique, we upgraded a home-built EPR spectrometer with an FPGA-enabled digitizer and real-time processing software. The software leverages the Hilbert transform to recover the in-phase (I) and quadrature (Q) channels, and therefore the raw absorptive and dispersive signals, χ' and χ'', from their combined magnitude (I2+Q2). Averaging a magnitude is simpler than real-time coherent averaging and has the added benefit of permitting long-timescale signal averaging (up to at least 2.5×106 scans) because it eliminates the effects of source-receiver phase drift. Our rapid-scan (RS) EPR provides a signal-to-noise ratio that is approximately twice that of continuous wave (CW) EPR under the same experimental conditions, after scaling by the square root of acquisition time. We apply our RS EPR as an extension of the recently reported time-resolved Gd-Gd EPR (TiGGER) [Maity et al., 2023], which is able to monitor inter-residue distance changes during the photocycle of a photoresponsive protein through changes in the Gd-Gd dipolar couplings. RS, opposed to CW, returns field-swept spectra as a function of time with 10ms time resolution, and thus, adds a second dimension to the static field transients recorded by TiGGER. We were able to use RS TiGGER to track time-dependent and temperature-dependent kinetics of AsLOV2, a light-activated phototropin domain found in oats. The results presented here combine the benefits of RS EPR with the improved spectral resolution and sensitivity of Gd chelates at high magnetic fields. In the future, field-domain RS EPR at high magnetic fields may enable studies of other real-time kinetic processes with time resolutions that are otherwise difficult to access in the solution state.
Collapse
Affiliation(s)
- Brad D Price
- Department of Physics, University of California, Santa Barbara, 93106, CA, USA; Institute for Terahertz Science and Technology, University of California, Santa Barbara, 93106, CA, USA.
| | - Antonín Sojka
- Department of Physics, University of California, Santa Barbara, 93106, CA, USA; Institute for Terahertz Science and Technology, University of California, Santa Barbara, 93106, CA, USA
| | - Shiny Maity
- Department of Chemistry, University of California, Santa Barbara, 93106, CA, USA; Department of Chemistry, Northwestern University, 633 Clark Street, Evanston, 60208, IL, USA
| | - I Marcelo Chavez
- Department of Chemistry, University of California, Santa Barbara, 93106, CA, USA
| | - Matthieu Starck
- Department of Chemistry, Durham University, Durham, DH13LE, UK
| | - Maxwell Z Wilson
- Department Molecular, Cellular, and Developmental Biology, University of California, Santa Barbara, 93106, CA, USA
| | - Songi Han
- Department of Chemistry, University of California, Santa Barbara, 93106, CA, USA; Department of Chemistry, Northwestern University, 633 Clark Street, Evanston, 60208, IL, USA
| | - Mark S Sherwin
- Department of Physics, University of California, Santa Barbara, 93106, CA, USA; Institute for Terahertz Science and Technology, University of California, Santa Barbara, 93106, CA, USA.
| |
Collapse
|
3
|
Nir-Arad O, Fialkov AB, Shlomi DH, Manukovsky N, Mentink-Vigier F, Kaminker I. High-field pulsed EPR spectroscopy under magic angle spinning. SCIENCE ADVANCES 2024; 10:eadq6073. [PMID: 39213356 PMCID: PMC11364107 DOI: 10.1126/sciadv.adq6073] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/23/2024] [Accepted: 07/29/2024] [Indexed: 09/04/2024]
Abstract
In this work, we demonstrate the first pulsed electron paramagnetic resonance (EPR) experiments performed under magic angle spinning (MAS) at high magnetic field. Unlike nuclear magnetic resonance (NMR) and dynamic nuclear polarization (DNP), commonly performed at high magnetic fields and under MAS to maximize sensitivity and resolution, EPR is usually measured at low magnetic fields and, with the exception of the Spiess group work in the late 1990s, never under MAS, due to great instrumentational challenges. This hampers the investigation of DNP mechanisms, in which electron spin dynamics play a central role, because no experimental data about the latter under DNP-characteristic conditions are available. We hereby present our dedicated, homebuilt MAS-EPR probehead and show the pulsed MAS-EPR spectra of P1 center diamond defect recorded at 7 tesla. Our results reveal unique effects of MAS on EPR line shape, intensity, and signal dephasing. Time-domain simulations reproduce the observed changes in the line shapes and the trends in the signal intensity.
Collapse
Affiliation(s)
- Orit Nir-Arad
- School of Chemistry, Tel-Aviv University, 6997801 Tel-Aviv, Israel
| | | | - David H. Shlomi
- School of Chemistry, Tel-Aviv University, 6997801 Tel-Aviv, Israel
| | - Nurit Manukovsky
- School of Chemistry, Tel-Aviv University, 6997801 Tel-Aviv, Israel
| | - Frederic Mentink-Vigier
- National High Magnetic Field Laboratory, Florida State University, Tallahassee, FL 32310, USA
| | - Ilia Kaminker
- School of Chemistry, Tel-Aviv University, 6997801 Tel-Aviv, Israel
| |
Collapse
|
4
|
Tesi L, Hrtoň M, Bloos D, Hentschel M, Šikola T, van Slageren J. Terahertz magnetic response of plasmonic metasurface resonators: origin and orientation dependence. Sci Rep 2024; 14:15305. [PMID: 38961198 PMCID: PMC11222506 DOI: 10.1038/s41598-024-65804-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2024] [Accepted: 06/24/2024] [Indexed: 07/05/2024] Open
Abstract
The increasing miniaturization of everyday devices necessitates advancements in surface-sensitive techniques to access phenomena more effectively. Magnetic resonance methods, such as nuclear or electron paramagnetic resonance, play a crucial role due to their unique analytical capabilities. Recently, the development of a novel plasmonic metasurface resonator aimed at boosting the THz electron magnetic response in 2D materials resulted in a significant magnetic field enhancement, confirmed by both numerical simulations and experimental data. Yet, the mechanisms driving this resonance were not explored in detail. In this study, we elucidate these mechanisms using two semi-analytical models: one addressing the resonant behaviour and the other examining the orientation-dependent response, considering the anisotropy of the antennas and experimental framework. Our findings contribute to advancing magnetic spectroscopic techniques, broadening their applicability to 2D systems.
Collapse
Affiliation(s)
- Lorenzo Tesi
- Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.
| | - Martin Hrtoň
- Institute of Physical Engineering and Central European Institute of Technology, Brno University of Technology, Technická 2, 61669, Brno, Czech Republic
| | - Dominik Bloos
- Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany
| | - Mario Hentschel
- 4th Physics Institute and Research Center SCoPE, University of Stuttgart, Pfaffenwaldring 57, 70569, Stuttgart, Germany
| | - Tomáš Šikola
- Institute of Physical Engineering and Central European Institute of Technology, Brno University of Technology, Technická 2, 61669, Brno, Czech Republic
| | - Joris van Slageren
- Institute of Physical Chemistry, University of Stuttgart, Pfaffenwaldring 55, 70569, Stuttgart, Germany.
- Center for Integrated Quantum Science and Technology, University of Stuttgart, Stuttgart, Germany.
| |
Collapse
|
5
|
Nir-Arad O, Shlomi DH, Israelstam A, Amit T, Manukovsky N, Fialkov AB, Kaminker I. The CW-EPR Capabilities of a Dual DNP/EPR Spectrometer Operating at 14 and 7 T. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2024; 360:107635. [PMID: 38401475 DOI: 10.1016/j.jmr.2024.107635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 12/24/2023] [Accepted: 02/07/2024] [Indexed: 02/26/2024]
Abstract
High-field electron paramagnetic resonance (EPR) measurements are indispensable for a better understanding of dynamic nuclear polarization (DNP), which relies on polarization transfer between electron and nuclear spins. DNP experiments are typically performed at high > 7 T magnetic fields and low ≤ 100 K temperatures, while EPR instrumentation capable of EPR measurements under these conditions is scarce. In this paper, we describe the CW EPR capabilities of a dual DNP/EPR spectrometer that is designed to carry out EPR experiments under "DNP conditions" at 14 and 7 T. In the first part, we present the design of this instrument, highlighting the choices made to allow for both DNP and EPR operations. The spectrometer uses a sweepable cryogen-free magnet with NMR-grade homogeneity, a closed-cycle cooling system, a quasi-optical induction mode bridge, and a superheterodyne receiver system. The probe design is optimized for low heat load and fast sample exchange under cryogenic conditions. The spectrometer can operate in frequency and field sweep modes, including wide field sweeps using the main coil of the magnet. In the second part, we present EPR spectra acquired over a wide range of samples and operating conditions, illustrating the CW EPR capabilities of the instrument.
Collapse
Affiliation(s)
- Orit Nir-Arad
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - David H Shlomi
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Amit Israelstam
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Tomer Amit
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Nurit Manukovsky
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Alexander B Fialkov
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Ilia Kaminker
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel.
| |
Collapse
|
6
|
Šedivý M, Santana V, Sojka A, Laguta O, Neugebauer P. MEPROS - Modular electron paramagnetic resonance operating software for multifunctional high-frequency EPR spectrometer. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2023; 355:107556. [PMID: 37751649 DOI: 10.1016/j.jmr.2023.107556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 09/07/2023] [Accepted: 09/11/2023] [Indexed: 09/28/2023]
Abstract
We present a software solution developed in LabVIEW for a home-built High-Frequency Electron Paramagnetic Resonance (HF-EPR) spectrometer. A modular approach was applied to control the spectrometer subsystems and simplify the adaptation to hardware changes during the development. The solution implements measuring procedures for conventional Continuous Wave EPR (CW-EPR), Frequency-Swept EPR (FS-EPR), and Two-Dimensional EPR (2D-EPR) mapping, which are relevant in different cases. The software's automation capabilities were tested in several trial measurements to obtain CW-EPR spectra of Silicon Carbide doped by vanadium (SiC + V) at various temperatures and microwave frequencies, multi-frequency spectra via 2D-EPR mapping, and dense FS-EPR data of a lithium phthalocyanine crystal rotated in a magnetic field. Several prospective modifications of the software are discussed in the conclusion. A modular character allows the easy re-use of code portions in other experimental setups. The spectrometer and the software are currently deployed and utilized in a laboratory of EPR spectroscopy at Central European Institute of Technology (CEITEC) in Brno, and data obtained by it has been already used in a number of publications.
Collapse
Affiliation(s)
- Matúš Šedivý
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic; Department of Microelectronics, Faculty of Electrical Engineering and Communication, Brno University of Technology, Czech Republic.
| | - Vinicius Santana
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic
| | - Antonín Sojka
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic
| | - Oleksii Laguta
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic
| | - Petr Neugebauer
- Magneto-Optical and THz Spectroscopy, Central European Institute of Technology (CEITEC), Brno University of Technology (BUT), Czech Republic.
| |
Collapse
|
7
|
O'Connell RC, Tseytlin O, Bobko AA, Eubank TD, Tseytlin M. Rapid scan EPR: Automated digital resonator control for low-latency data acquisition. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2022; 345:107308. [PMID: 36356489 PMCID: PMC10266206 DOI: 10.1016/j.jmr.2022.107308] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 10/05/2022] [Accepted: 10/06/2022] [Indexed: 06/05/2023]
Abstract
Automation has become an essential component of modern scientific instruments which often capture large amounts of complex dynamic data. Algorithms are developed to read multiple sensors in parallel with data acquisition and to adjust instrumental parameters on the fly. Decisions are made on a time scale unattainable to the human operator. In addition to speed, automation reduces human error, improves the reproducibility of experiments, and improves the reliability of acquired data. An automatic digital control (ADiC) was developed to reliably sustain critical coupling of a resonator over a wide range of time-varying loading conditions. The ADiC uses the computational power of a microcontroller that directly communicates with all system components independent of a personal computer (PC). The PC initiates resonator tuning and coupling by sending a command to MC via serial port. After receiving the command, ADiC establishes critical coupling conditions within approximately 5 ms. A printed circuit board resonator was designed to permit digital control. The performance of the resonator together with the ADiC was evaluated by varying the resonator loading from empty to heavily loaded. For the loading, samples containing aqueous sodium chloride that strongly absorb electromagnetic waves were used. A previously reported rapid scan (RS) electron paramagnetic resonance (EPR) imaging instrument was upgraded by the incorporation of ADiC. RS spectra and an in vivo image of oxygen in a mouse tumor model have been acquired using the upgraded system. ADiC robustly sustained critical coupling of the resonator to the transmission line during these measurements. The design implemented in this study can be used in slow-scan and pulsed EPR with modifications.
Collapse
Affiliation(s)
- Ryan C O'Connell
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA
| | - Oxana Tseytlin
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA
| | - Andrey A Bobko
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA
| | - Timothy D Eubank
- In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA; Department of Microbiology, Immunology and Cell Biology, West Virginia University, Morgantown, WV 26506, USA
| | - Mark Tseytlin
- Department of Biochemistry and Molecular Medicine, West Virginia University, Morgantown, WV 26506, USA; West Virginia University Cancer Institute, Morgantown, WV 26506, USA; In Vivo Multifunctional Magnetic Resonance Center at Robert C. Byrd Health Sciences Center, West Virginia University, Morgantown, WV 26506, USA.
| |
Collapse
|
8
|
Abstract
Progress has been made in hardware for low frequencies, demonstrations of rapid frequency scans, hybrid instrumentation, and improved deconvolution software. The recent availability of the commercial Bruker BioSpin rapid scan accessory for their X-band EMX and Elexsys systems makes this technique available to a wide range of users without the need to construct their own system. Developments at lower frequencies are underway in several labs with the goal of facilitating in vivo and preclinical rapid scan imaging. Development of new deconvolution algorithms will make data processing more robust. Frequency scans have substantial promise at higher frequencies. New examples of applications show the wide applicability and advantages of rapid scan.
Collapse
Affiliation(s)
- Gareth R Eaton
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO, United States.
| | - Sandra S Eaton
- Department of Chemistry and Biochemistry, University of Denver, Denver, CO, United States
| |
Collapse
|
9
|
Marko A, Sojka A, Laguta O, Neugebauer P. Simulation of nitrogen nuclear spin magnetization of liquid solved nitroxides. Phys Chem Chem Phys 2021; 23:17310-17322. [PMID: 34346404 PMCID: PMC8371994 DOI: 10.1039/d0cp06071b] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2020] [Accepted: 06/25/2021] [Indexed: 12/15/2022]
Abstract
Nitroxide radicals are widely used in electron paramagnetic resonance (EPR) applications. Nitroxides are stable organic radicals containing the N-O˙ group with hyperfine coupled unpaired electron and nitrogen nuclear spins. In the past, much attention was devoted to studying nitroxide EPR spectra and electron spin magnetization evolution under various experimental conditions. However, the dynamics of nitrogen nuclear spin has not been investigated in detail so far. In this work, we performed quantitative prediction and simulation of nitrogen nuclear spin magnetization evolution in several magnetic resonance experiments. Our research was focused on fast rotating nitroxide radicals in liquid solutions. We used a general approach allowing us to compute electron and nitrogen nuclear spin magnetization from the same time-dependent spin density matrix obtained by solving the Liouville/von Neumann equation. We investigated the nitrogen nuclear spin dynamics subjected to various radiofrequency magnetic fields. Furthermore, we predicted a large dynamic nuclear polarization of nitrogen upon nitroxide irradiation with microwaves and analyzed its effect on the nitroxide EPR saturation factor.
Collapse
Affiliation(s)
- Andriy Marko
- Central European Institute of Technology, Brno University of TechnologyPurkynova-Str. 12361200BrnoCzech Republic
| | - Antonin Sojka
- Central European Institute of Technology, Brno University of TechnologyPurkynova-Str. 12361200BrnoCzech Republic
| | - Oleksii Laguta
- Central European Institute of Technology, Brno University of TechnologyPurkynova-Str. 12361200BrnoCzech Republic
| | - Petr Neugebauer
- Central European Institute of Technology, Brno University of TechnologyPurkynova-Str. 12361200BrnoCzech Republic
| |
Collapse
|
10
|
Künstner S, Chu A, Dinse KP, Schnegg A, McPeak J, Naydenov B, Anders J, Lips K. Rapid-scan electron paramagnetic resonance using an EPR-on-a-Chip sensor. MAGNETIC RESONANCE (GOTTINGEN, GERMANY) 2021; 2:673-687. [PMID: 37905212 PMCID: PMC10539758 DOI: 10.5194/mr-2-673-2021] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 08/17/2021] [Indexed: 11/02/2023]
Abstract
Electron paramagnetic resonance (EPR) spectroscopy is the method of choice to investigate and quantify paramagnetic species in many scientific fields, including materials science and the life sciences. Common EPR spectrometers use electromagnets and microwave (MW) resonators, limiting their application to dedicated lab environments. Here, novel aspects of voltage-controlled oscillator (VCO)-based EPR-on-a-Chip (EPRoC) detectors are discussed, which have recently gained interest in the EPR community. More specifically, it is demonstrated that with a VCO-based EPRoC detector, the amplitude-sensitive mode of detection can be used to perform very fast rapid-scan EPR experiments with a comparatively simple experimental setup to improve sensitivity compared to the continuous-wave regime. In place of a MW resonator, VCO-based EPRoC detectors use an array of injection-locked VCOs, each incorporating a miniaturized planar coil as a combined microwave source and detector. A striking advantage of the VCO-based approach is the possibility of replacing the conventionally used magnetic field sweeps with frequency sweeps with very high agility and near-constant sensitivity. Here, proof-of-concept rapid-scan EPR (RS-EPRoC) experiments are performed by sweeping the frequency of the EPRoC VCO array with up to 400 THz s- 1 , corresponding to a field sweep rate of 14 kT s- 1 . The resulting time-domain RS-EPRoC signals of a micrometer-scale BDPA sample can be transformed into the corresponding absorption EPR signals with high precision. Considering currently available technology, the frequency sweep range may be extended to 320 MHz, indicating that RS-EPRoC shows great promise for future sensitivity enhancements in the rapid-scan regime.
Collapse
Affiliation(s)
- Silvio Künstner
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany
| | - Anh Chu
- Institute of Smart Sensors, Universität Stuttgart, Pfaffenwaldring 47, 70569 Stuttgart, Germany
| | - Klaus-Peter Dinse
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany
- Berlin Joint EPR Laboratory, Fachbereich Physik, Freie Universität Berlin, Arnimallee 14, 14195 Berlin, Germany
| | - Alexander Schnegg
- EPR4Energy, Max-Planck-Institut für chemische Energiekonversion, Stiftstraße 34–36, 45470 Mülheim an der Ruhr, Germany
| | - Joseph E. McPeak
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany
| | - Boris Naydenov
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany
| | - Jens Anders
- Institute of Smart Sensors, Universität Stuttgart, Pfaffenwaldring 47, 70569 Stuttgart, Germany
- Center for Integrated Quantum Science and Technology (IQST), Stuttgart and Ulm, Germany
| | - Klaus Lips
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPIN), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany
- Berlin Joint EPR Laboratory, Fachbereich Physik, Freie Universität Berlin, Arnimallee 14, 14195 Berlin, Germany
| |
Collapse
|
11
|
Biller JR, McPeak JE. EPR Everywhere. APPLIED MAGNETIC RESONANCE 2021; 52:1113-1139. [PMID: 33519097 PMCID: PMC7826499 DOI: 10.1007/s00723-020-01304-z] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/09/2020] [Revised: 10/16/2020] [Accepted: 12/06/2020] [Indexed: 06/12/2023]
Abstract
This review is inspired by the contributions from the University of Denver group to low-field EPR, in honor of Professor Gareth Eaton's 80th birthday. The goal is to capture the spirit of innovation behind the body of work, especially as it pertains to development of new EPR techniques. The spirit of the DU EPR laboratory is one that never sought to limit what an EPR experiment could be, or how it could be applied. The most well-known example of this is the development and recent commercialization of rapid-scan EPR. Both of the Eatons have made it a point to remain knowledgeable on the newest developments in electronics and instrument design. To that end, our review touches on the use of miniaturized electronics and applications of single-board spectrometers based on software-defined radio (SDR) implementations and single-chip voltage-controlled oscillator (VCO) arrays. We also highlight several non-traditional approaches to the EPR experiment such as an EPR spectrometer with a "wand" form factor for analysis of the OxyChip, the EPR-MOUSE which enables non-destructive in situ analysis of many non-conforming samples, and interferometric EPR and frequency swept EPR as alternatives to classical high Q resonant structures.
Collapse
Affiliation(s)
| | - Joseph E. McPeak
- University of Denver, Denver, CO 80210 USA
- Berlin Joint EPR Laboratory and EPR4Energy, Department Spins in Energy Conversion and Quantum Information Science (ASPINS), Helmholtz-Zentrum Berlin für Materialien und Energie GmbH, Hahn-Meitner-Platz 1, 14109 Berlin, Germany
| |
Collapse
|