1
|
Nir-Arad O, Shlomi DH, Israelstam A, Amit T, Manukovsky N, Fialkov AB, Kaminker I. The CW-EPR Capabilities of a Dual DNP/EPR Spectrometer Operating at 14 and 7 T. J Magn Reson 2024; 360:107635. [PMID: 38401475 DOI: 10.1016/j.jmr.2024.107635] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/10/2023] [Revised: 12/24/2023] [Accepted: 02/07/2024] [Indexed: 02/26/2024]
Abstract
High-field electron paramagnetic resonance (EPR) measurements are indispensable for a better understanding of dynamic nuclear polarization (DNP), which relies on polarization transfer between electron and nuclear spins. DNP experiments are typically performed at high > 7 T magnetic fields and low ≤ 100 K temperatures, while EPR instrumentation capable of EPR measurements under these conditions is scarce. In this paper, we describe the CW EPR capabilities of a dual DNP/EPR spectrometer that is designed to carry out EPR experiments under "DNP conditions" at 14 and 7 T. In the first part, we present the design of this instrument, highlighting the choices made to allow for both DNP and EPR operations. The spectrometer uses a sweepable cryogen-free magnet with NMR-grade homogeneity, a closed-cycle cooling system, a quasi-optical induction mode bridge, and a superheterodyne receiver system. The probe design is optimized for low heat load and fast sample exchange under cryogenic conditions. The spectrometer can operate in frequency and field sweep modes, including wide field sweeps using the main coil of the magnet. In the second part, we present EPR spectra acquired over a wide range of samples and operating conditions, illustrating the CW EPR capabilities of the instrument.
Collapse
Affiliation(s)
- Orit Nir-Arad
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - David H Shlomi
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Amit Israelstam
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Tomer Amit
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Nurit Manukovsky
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Alexander B Fialkov
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Ilia Kaminker
- School of Chemistry, Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 6997801, Israel.
| |
Collapse
|
2
|
Amirav A, Fialkov AB, Gordin A, Elkabets O, Margolin Eren KJ. Cold Electron Ionization (EI) Is Not a Supplementary Ion Source to Standard EI. It is a Highly Superior Replacement Ion Source. J Am Soc Mass Spectrom 2021; 32:2631-2635. [PMID: 34652909 PMCID: PMC8589250 DOI: 10.1021/jasms.1c00241] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/15/2021] [Revised: 09/30/2021] [Accepted: 10/01/2021] [Indexed: 06/13/2023]
Abstract
GC-MS usually employs a 70 eV electron ionization (EI) ion source, which provides mass spectra with detailed fragment ion information that are amenable for library search and identification with names and structures at the isomer level. However, conventional EI often suffers from low intensity or the absence of molecular ions, which reduces detection and identification capabilities in analyses. In an attempt to enhance the molecular ions, several softer ion sources are being used to supplement standard EI, including chemical ionization (CI), atmospheric pressure chemical ionization (APCI), field ionization (FI), photoionization (PI), and low electron energy EI. However, the most advantageous way to enhance molecular ions is to use cold EI, which employs 70 eV EI of cold molecules in supersonic molecular beams. Cold EI yields classical EI mass spectra with highly enhanced molecular ions, which still provides high detectability and library-searchable mass spectra. In this paper, we explain and discuss why cold EI is not a supplementary ion source to standard EI, but rather it is a highly superior replacement to standard EI. With cold EI, there is no need for standard EI or any other supplemental ion source. We describe 16 benefits and unique features of cold EI that not only yield better results for existing applications but also significantly extend the range of compounds and applications amenable for GC-MS analysis.
Collapse
Affiliation(s)
- Aviv Amirav
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
- Aviv
Analytical Ltd., 24 Hanagar
Street, Hod Hasharon 4527713, Israel
| | | | - Alexander Gordin
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | - Oneg Elkabets
- School
of Chemistry, Tel Aviv University, Tel Aviv 6997801, Israel
| | | |
Collapse
|
3
|
Amirav A, Neumark B, Margolin Eren KJ, Fialkov AB, Tal N. Cannabis and its cannabinoids analysis by gas chromatography-mass spectrometry with Cold EI. J Mass Spectrom 2021; 56:e4726. [PMID: 33955098 DOI: 10.1002/jms.4726] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 03/14/2021] [Accepted: 03/15/2021] [Indexed: 06/12/2023]
Abstract
Cannabis extracts and products were analyzed by gas chromatography-mass spectrometry (GC-MS) with Cold EI for their full content including terpenes, sesquiterpenes, sesquiterpinols, fatty acids, delta 9-tetrahydrocannabinol (THC), cannabidiol (CBD), other cannabinoids, hydrocarbons, sterols, diglycerides, triglycerides, and impurities. GC-MS with Cold EI is based on interfacing GC and MS with supersonic molecular beams (SMB) along with electron ionization of vibrationally cold sample compounds in the SMB in a fly-through ion source (hence the name Cold EI). GC-MS with Cold EI improves all the performance aspects of GC-MS, enables the analysis of Cannabinoids with OH groups without derivatization, while providing enhanced molecular ions for improved identification, and enables internal quantitation without calibration. We found over 50 cannabinoid compounds including a new one with a Cold EI mass spectrum very similar to delta 9-THC as well as relatively large cannabinoids with molecular weight above m/z = 400. Because the analysis was universal in full scan and not targeted, we found impurities such as bromo CBD and fluticasone propionate and could monitor the formation of oxidized CBD during decarboxylation. In addition, GC-MS with Cold EI enabled nontargeted full analysis of terpenes, sesquiterpenes, and sesquiterpinols in cannabis extracts with good internal quantitation. GC-MS with Cold EI further served with very good sensitivity for the concentration determination of delta 9-THC in CBD-related products. Finally, cannabis drugs such as EP-1 used in Israel for treatment of epilepsy and for children with autism spectrum disorder (ASD) were analyzed for their full cannabinoids content for learning on the entourage effect and for drug activity optimization.
Collapse
Affiliation(s)
- Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, Israel
- Aviv Analytical Ltd, Hod Hasharon, Israel
| | - Benny Neumark
- School of Chemistry, Tel Aviv University, Tel Aviv, Israel
| | | | | | - Noam Tal
- School of Chemistry, Tel Aviv University, Tel Aviv, Israel
| |
Collapse
|
4
|
Tsizin S, Fialkov AB, Amirav A. Analysis of impurities in pharmaceuticals by LC-MS with cold electron ionization. J Mass Spectrom 2020; 55:e4587. [PMID: 32662574 DOI: 10.1002/jms.4587] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Revised: 06/08/2020] [Accepted: 06/08/2020] [Indexed: 06/11/2023]
Abstract
Pharmaceuticals require careful and precise determination of their impurities that might harm the user upon consumption. Although today, the most common technique for impurities identification is liquid chromatography-mass spectrometry (LC-MS/MS), it has several downsides due to the nature of the ionization method. Also, the analyses in many cases are targeted thus despite being present, some of the compounds will not be revealed. In this paper, we propose and show a new method for untargeted analysis and identification of impurities in active pharmaceutical ingredients (APIs). The instrument used for these analyses is a novel electron ionization (EI) LC-MS with supersonic molecular beams (SMB). The EI-LC-MS-SMB was implemented for analyses of several drug samples spiked with an impurity. The instrument provides EI mass spectra with enhanced molecular ions, named Cold EI, which increases the identification probabilities when the compound is identified with the aid of an EI library like National Institute of Standards and Technology (NIST). We analyzed ibuprofen and its impurities, and both the API and the expected impurity were identified with names and structures by the NIST library. Moreover, other unexpected impurities were found and identified proving the ability of the EI-LC-MS-SMB system for truly untargeted analysis. The results show a broad dynamic range of four orders of magnitude at the same run with a signal-to-noise ratio of over 10 000 for the API and almost uniform response.
Collapse
Affiliation(s)
- Svetlana Tsizin
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | | | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| |
Collapse
|
5
|
Fialkov AB, Ikonen E, Laaksonen T, Amirav A. GC-MS with photoionization of cold molecules in supersonic molecular beams-Approaching the softest ionization method. J Mass Spectrom 2020; 55:e4516. [PMID: 32567120 DOI: 10.1002/jms.4516] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2020] [Revised: 03/18/2020] [Accepted: 03/23/2020] [Indexed: 06/11/2023]
Abstract
A new type of photoionization ion source was developed for the ionization of cold molecules in supersonic molecular beams (named Cold PI). The system was based on a GC-MS with supersonic molecular beams and its fly-through EI of cold molecules ion source (Cold EI) plus quadrupole mass analyzer. A continuously operated deuterium VUV photoionization lamp was added and placed above and between the supersonic nozzle and skimmer whereas the Cold EI ion source served only as a portion of the ion transfer ion optics. The supersonic nozzle and skimmer were voltage biased and the VUV light crossed the supersonic expansion about 10 mm from the nozzle. We obtained over three orders of magnitude enhancement in the relative abundance of the molecular ion of squalane in Cold PI versus in photoionization of this compound as a thermal compound. Accordingly, we also proved that standard photoionization is not as soft ionization method as previously perceived for large compounds. We found that Cold PI is as soft as and possibly softer than field ionization; thus, it could be the softest known ionization method. The ionization yield was about 200-300 times weaker than with Cold EI yet our limit of detection was about 200 femtogram in SIM mode for cholesterol and pyrene which is reasonable. Practically, all hydrocarbons gave only molecular ions with rather uniform response whereas alcohols gave some molecular ions plus major fragment ions particularly with a loss of water (similarly to field ionization). We tested Cold PI in the GC-MS analysis of diesel fuels and analyzed the time averaged data for group type information. We also found that we can analyze the diesel fuels by fast under 20-s flow injection analysis in which the generated averaged mass spectrum of molecular ions only could serve for the characterization of fuels.
Collapse
Affiliation(s)
| | | | | | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| |
Collapse
|
6
|
Tsizin S, Fialkov AB, Amirav A. Electron Ionization Mass Spectrometry for Both Liquid and Gas Chromatography in One System without the Need for Hardware Adjustments. J Am Soc Mass Spectrom 2020; 31:1713-1721. [PMID: 32543199 DOI: 10.1021/jasms.0c00136] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A new instrument that bridges the gap between gas chromatography (GC) and liquid chromatography (LC) mass spectrometry (MS) was developed. In this instrument GC-MS and electron ionization LC-MS were combined in one MS system with method based mode changing. The LC pneumatic spray formation interface to MS was mounted on top of an otherwise unused GC detector slot and was connected with a flow restriction capillary to the MS through the GC oven and into the MS transfer line, parallel to the GC capillary column. The LC output mobile phase flow is directed into a spray formation and vaporization chamber. The pneumatic spray results in fine spray droplets that are thermally vaporized at a pressure equal to or greater than ambient. A portion of the vaporized mixture is directed into the heated flow restriction capillary that connects the spray formation and vaporization chamber into the electron ionization (EI) ion source, while most of the vaporized spray is released to the atmosphere. The combined GC-MS and LC-MS system can work either with standard EI or with cold EI via interfacing the flow restriction capillary into a supersonic nozzle forming a supersonic molecular beam of a vibrationally cold sample compound. We found that EI-LC-MS with cold EI has many benefits when compared with standard EI. The EI-LC-MS interface can also serve for flow injection analysis. The performance of the combined system is demonstrated in the analysis of a few sample mixtures by both GC-MS and LC-MS analysis, sequentially without hardware adjustments.
Collapse
Affiliation(s)
- Svetlana Tsizin
- School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel
| | | | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel
| |
Collapse
|
7
|
Abstract
We report the finding of doubly charged molecular ions in a range of relatively large molecules including hydrocarbons upon their electron ionization as vibrationally cold molecules in supersonic molecular beams (SMB) (also named as Cold EI). Furthermore, we also report the detection by mass spectrometry of triply charged molecular ions in large PAHs such as decacyclene and ovalene upon their cooling in SMB. We found that the relative abundance of doubly charged molecular ions strongly depends on the internal vibrational cooling. While after some vibrational cooling the fragmentation pattern became cooling independent, the relative abundance of the doubly charged molecular ions was noticeably increased upon further cooling via increasing of the cooling make-up gas flow rate. In addition, the relative abundance of the doubly charged molecular ions was strongly increased with the compounds' size, and its electron energy threshold was lower than expected. These observations indicate a new mechanism that involves two separate electron ionization processes in the same compound, most likely with the same electron but at two separate atoms (places) in large molecules, to reduce Coulombic repulsion energy that can lead to fragmentation into two singly charged ions. These findings are shedding new light on electron ionization mass spectra. Accordingly, electron ionization mass spectra are the result of three separate mechanisms with relative magnitudes that depend on the compound size: (a) single electron ionization; (b) double electron ionization; and (c) single electron ionization with subsequent internal excitation by the same ionizing electron in another place.
Collapse
Affiliation(s)
| | | | - Uri Keshet
- School of Chemistry , Tel Aviv University , Tel Aviv 6997801 , Israel
| | - Svetlana Tsizin
- School of Chemistry , Tel Aviv University , Tel Aviv 6997801 , Israel
| | - Aviv Amirav
- School of Chemistry , Tel Aviv University , Tel Aviv 6997801 , Israel
- Aviv Analytical Ltd. , 24 Hanagar Street Hod , Hasharon 4527713 , Israel
| |
Collapse
|
8
|
Fialkov AB, Lehotay SJ, Amirav A. Less than one minute low-pressure gas chromatography - mass spectrometry. J Chromatogr A 2019; 1612:460691. [PMID: 31759639 DOI: 10.1016/j.chroma.2019.460691] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2019] [Revised: 11/05/2019] [Accepted: 11/06/2019] [Indexed: 01/08/2023]
Abstract
Conventional gas chromatography - mass spectrometry (GC-MS) takes 20-40 min per sample, which is undesirably slow in any application if speed can be increased while still meeting analytical needs. In this study, we achieved reasonably good separations with full analysis cycle times of less than 1 min by combining for the first time low-pressure (LP) GC-MS with low thermal mass (LTM) resistive-heating for rapid temperature ramping and cooling of the capillary column. The analytical column is threaded into the LTM thin-walled metal tubing in an instrumental device known as "LTM Fast GC" that is mounted at the top of the gas chromatograph in a detector port. The column inlet and outlet are connected to the GC injector and MS transfer line as usual. For LPGC-MS, a 40 cm, 0.1 mm. i.d. uncoated flow restrictor capillary connected at the injector is coupled with a 2.6 m, 0.25 mm i.d., 0.25 µm film thickness analytical column leading to the MS. Thus, the inlet operates at normal GC pressures, but the analytical column is under vacuum, which increases the optimal helium carrier gas flow velocity thereby increasing speed of full range separations while maintaining acceptable quality of chromatography. This column configuration in LTM-LPGC-MS trades a 64-fold gain in speed of analysis vs. standard GC-MS for a 4-fold loss in chromatographic peak capacity, thereby converting analysis time from minutes into seconds in common applications. For example, jet fuel containing fatty acid methyl esters (akin to biofuel) was separated in 25 s with <1 min full analysis cycle time. An EPA Method 8270 mixture of 76 analytes was also analyzed in <1 min full cycle time by LTM-LPGC-MS. Other examples include very fast analysis of heroin in a street drug powder and elucidation of a new organic synthetic compound. In this report, we describe and discuss the several advantageous and practical features of LTM-LPGC-MS, as well as its trade-offs.
Collapse
Affiliation(s)
| | - Steven J Lehotay
- U.S. Department of Agriculture, Agricultural Research Service, Eastern Regional Research Center, 600 East Mermaid Lane, Wyndmoor, PA 10938, USA
| | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv 69978, Israel; Aviv Analytical Ltd., 24 Hanagar Street, Hod Hasharon 4527713, Israel.
| |
Collapse
|
9
|
Keshet U, Alon T, Fialkov AB, Amirav A. Open Probe fast GC-MS - combining ambient sampling ultra-fast separation and in-vacuum ionization for real-time analysis. J Mass Spectrom 2017; 52:417-426. [PMID: 28455844 DOI: 10.1002/jms.3941] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2017] [Revised: 04/02/2017] [Accepted: 04/25/2017] [Indexed: 06/07/2023]
Abstract
An Open Probe inlet was combined with a low thermal mass ultra-fast gas chromatograph (GC), in-vacuum electron ionization ion source and a mass spectrometer (MS) of GC-MS for obtaining real-time analysis with separation. The Open Probe enables ambient sampling via sample vaporization in an oven that is open to room air, and the ultra-fast GC provides ~30-s separation, while if no separation is required, it can act as a transfer line with 2 to 3-s sample transfer time. Sample analysis is as simple as touching the sample, pushing the sample holder into the Open Probe oven and obtaining the results in 30 s. The Open Probe fast GC was mounted on a standard Agilent 7890 GC that was coupled with an Agilent 5977A MS. Open Probe fast GC-MS provides real-time analysis combined with GC separation and library identification, and it uses the low-cost MS of GC-MS. The operation of Open Probe fast GC-MS is demonstrated in the 30-s separation and 50-s full analysis cycle time of tetrahydrocannabinol and cannabinol in Cannabis flower, sub 1-min analysis of trace trinitrotoluene transferred from a finger onto a glass surface, vitamin E in canola oil, sterols in olive oil, polybrominated flame retardants in plastics, alprazolam in Xanax drug pill and free fatty acids and cholesterol in human blood. The extrapolated limit of detection for pyrene is <1 fg, but the concentration is too high and the software noise calculation is untrustworthy. The broad range of compounds amenable for analysis is demonstrated in the analysis of reserpine. The possible use with alternate standard GC-MS and Open Probe fast GC-MS is demonstrated in the analysis of heroin in its street drug powder. The use of Open Probe with the fast GC acting as a transfer line is demonstrated in <10-s analysis without separation of ibuprofen and estradiol. Copyright © 2017 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- U Keshet
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - T Alon
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - A B Fialkov
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - A Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| |
Collapse
|
10
|
Seemann B, Alon T, Tsizin S, Fialkov AB, Amirav A. Electron ionization LC-MS with supersonic molecular beams--the new concept, benefits and applications. J Mass Spectrom 2015; 50:1252-63. [PMID: 26505770 DOI: 10.1002/jms.3695] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/05/2015] [Revised: 08/19/2015] [Accepted: 08/20/2015] [Indexed: 05/28/2023]
Abstract
A new type of electron ionization LC-MS with supersonic molecular beams (EI-LC-MS with SMB) is described. This system and its operational methods are based on pneumatic spray formation of the LC liquid flow in a heated spray vaporization chamber, full sample thermal vaporization and subsequent electron ionization of vibrationally cold molecules in supersonic molecular beams. The vaporized sample compounds are transferred into a supersonic nozzle via a flow restrictor capillary. Consequently, while the pneumatic spray is formed and vaporized at above atmospheric pressure the supersonic nozzle backing pressure is about 0.15 Bar for the formation of supersonic molecular beams with vibrationally cold sample molecules without cluster formation with the solvent vapor. The sample compounds are ionized in a fly-though EI ion source as vibrationally cold molecules in the SMB, resulting in 'Cold EI' (EI of vibrationally cold molecules) mass spectra that exhibit the standard EI fragments combined with enhanced molecular ions. We evaluated the EI-LC-MS with SMB system and demonstrated its effectiveness in NIST library sample identification which is complemented with the availability of enhanced molecular ions. The EI-LC-MS with SMB system is characterized by linear response of five orders of magnitude and uniform compound independent response including for non-polar compounds. This feature improves sample quantitation that can be approximated without compound specific calibration. Cold EI, like EI, is free from ion suppression and/or enhancement effects (that plague ESI and/or APCI) which facilitate faster LC separation because full separation is not essential. The absence of ion suppression effects enables the exploration of fast flow injection MS-MS as an alternative to lengthy LC-MS analysis. These features are demonstrated in a few examples, and the analysis of the main ingredients of Cannabis on a few Cannabis flower extracts is demonstrated. Finally, the advantages of EI-LC-MS with SMB are listed and discussed.
Collapse
Affiliation(s)
- Boaz Seemann
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - Tal Alon
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | - Svetlana Tsizin
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| | | | - Aviv Amirav
- School of Chemistry, Tel Aviv University, Tel Aviv, 69978, Israel
| |
Collapse
|
11
|
Amirav A, Gordin A, Hagooly Y, Rozen S, Belgorodsky B, Seemann B, Marom H, Gozin M, Fialkov AB. Measurement and optimization of organic chemical reaction yields by GC–MS with supersonic molecular beams. Tetrahedron 2012. [DOI: 10.1016/j.tet.2012.05.031] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
12
|
Fialkov AB, Morag M, Amirav A. A low thermal mass fast gas chromatograph and its implementation in fast gas chromatography mass spectrometry with supersonic molecular beams. J Chromatogr A 2011; 1218:9375-83. [DOI: 10.1016/j.chroma.2011.10.053] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2011] [Revised: 10/18/2011] [Accepted: 10/20/2011] [Indexed: 10/15/2022]
|
13
|
Brondz I, Fialkov AB, Amirav A. Erratum to “Analysis of quinocide in unprocessed primaquine diphosphate and primaquine diphosphate tablets using gas chromatography–mass spectrometry with supersonic molecular beams” [J. Chromatogr. A 1216 (2009) 824–829]. J Chromatogr A 2009. [DOI: 10.1016/j.chroma.2009.01.049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
14
|
Brondz I, Fialkov AB, Amirav A. Analysis of quinocide in unprocessed primaquine diphosphate and primaquine diphosphate tablets using gas chromatography-mass spectrometry with supersonic molecular beams. J Chromatogr A 2009; 1216:824-9. [PMID: 19108846 DOI: 10.1016/j.chroma.2008.11.043] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2008] [Revised: 11/11/2008] [Accepted: 11/17/2008] [Indexed: 11/18/2022]
Abstract
Malaria is one of the most widespread and deadly diseases on the planet. Every year, about 500 million new cases are diagnosed, and the annual death toll is about 3 million. Primaquine has strong antiparasitic effects against gametocytes and can therefore prevent the spread of the parasite from treated patients to mosquitoes. It is also used in radical cures and prevents relapse. Consequently, primaquine is an often-used drug. In this study the separation of unprocessed primaquine from the contaminant quinocide based on gas chromatography-mass spectrometry with supersonic molecular beam (SMB) is presented and 7.5 mg primaquine diphosphate tablets were analyzed. We present a novel method for fast determination of quinocide which is an isomer of primaquine as the main contaminant in unprocessed primaquine and in its medical form as tablets by gas chromatography-mass spectrometry with SMB (also named supersonic GC-MS). Supersonic GC-MS provides enhanced molecular ion without any ion source related peak tailing plus extended range of compounds amenable for GC-MS analysis. In addition, major isomer mass spectral effects were revealed in the mass spectra of primaquine and quinocide which facilitated the unambiguous identification of quinocide in primaquine tablets. Fast GC-MS analysis is demonstrated with less then 2 min elution time of the drug and its main contaminants.
Collapse
Affiliation(s)
- Ilia Brondz
- Department of Biology, University of Oslo, Oslo, Norway.
| | | | | |
Collapse
|
15
|
Lehotay SJ, Mastovska K, Amirav A, Fialkov AB, Martos PA, Kok AD, Fernández-Alba AR. Identification and confirmation of chemical residues in food by chromatography-mass spectrometry and other techniques. Trends Analyt Chem 2008. [DOI: 10.1016/j.trac.2008.10.004] [Citation(s) in RCA: 72] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
16
|
Poliak M, Fialkov AB, Amirav A. Pulsed flow modulation two-dimensional comprehensive gas chromatography–tandem mass spectrometry with supersonic molecular beams. J Chromatogr A 2008; 1210:108-14. [DOI: 10.1016/j.chroma.2008.09.039] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2008] [Revised: 09/02/2008] [Accepted: 09/10/2008] [Indexed: 10/21/2022]
|
17
|
Gordin A, Fialkov AB, Amirav A. Classical electron ionization mass spectra in gas chromatography/mass spectrometry with supersonic molecular beams. Rapid Commun Mass Spectrom 2008; 22:2660-2666. [PMID: 18666200 DOI: 10.1002/rcm.3654] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/26/2023]
Abstract
A major benefit of gas chromatography/mass spectrometry (GC/MS) with a supersonic molecular beam (SMB) interface and its fly-through ion source is the ability to obtain electron ionization of vibrationally cold molecules (cold EI), which show enhanced molecular ions. However, GC/MS with an SMB also has the flexibility to perform 'classical EI' mode of operation which provides mass spectra to mimic those in commercial 70 eV electron ionization MS libraries. Classical EI in SMB is obtained through simple reduction of the helium make-up gas flow rate, which reduces the SMB cooling efficiency; hence the vibrational temperatures of the molecules are similar to those in traditional EI ion sources. In classical EI-SMB mode, the relative abundance of the molecular ion can be tuned and, as a result, excellent identification probabilities and very good matching factors to the NIST MS library are obtained. Classical EI-SMB with the fly-through dual cage ion source has analyte sensitivity similar to that of the standard EI ion source of a basic GC/MS system. The fly-through EI ion source in combination with the SMB interface can serve for cold EI, classical EI-SMB, and cluster chemical ionization (CCI) modes of operation, all easily exchangeable through a simple and quick change (not involving hardware). Furthermore, the fly-through ion source eliminates sample scattering from the walls of the ion source, and thus it offers full sample inertness, tailing-free operation, and no ion-molecule reaction interferences. It is also robust and enables increased column flow rate capability without affecting the sensitivity.
Collapse
Affiliation(s)
- Alexander Gordin
- School of Chemistry, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel
| | | | | |
Collapse
|
18
|
Abstract
Gas chromatography-mass spectrometry (GC-MS) with supersonic molecular beams (SMBs) (also named Supersonic GC-MS) is based on GC and MS interface with SMBs and on the electron ionization (EI) of vibrationally cold analytes in the SMBs (cold EI) in a fly-through ion source. This ion source is inherently inert and further characterized by fast response and vacuum background filtration capability. The same ion source offers three modes of ionization including cold EI, classical EI and cluster chemical ionization (CI). Cold EI, as a main mode, provides enhanced molecular ions combined with an effective library sample identification, which is supplemented and complemented by a powerful isotope abundance analysis method and software. The range of low-volatility and thermally labile compounds amenable for analysis is significantly increased owing to the use of the contact-free, fly-through ion source and the ability to lower sample elution temperatures through the use of high column carrier gas flow rates. Effective, fast GC-MS is enabled particularly owing to the possible use of high column flow rates and improved system selectivity in view of the enhancement of the molecular ion. This fast GC-MS with SMB can be further improved via the added selectivity of MS-MS, which by itself benefits from the enhancement of the molecular ion, the most suitable parent ion for MS-MS. Supersonic GC-MS is characterized by low limits of detection (LOD), and its sensitivity is superior to that of standard GC-MS, particularly for samples that are hard for analysis. The GC separation of the Supersonic GC-MS can be improved with pulsed flow modulation (PFM) GC x GC-MS. Electron ionization LC-MS with SMB can also be combined with the Supersonic GC-MS, with fast and easy switching between these two modes of operation.
Collapse
Affiliation(s)
- Aviv Amirav
- School of Chemistry, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel.
| | | | | | | |
Collapse
|
19
|
Fialkov AB, Amirav A. Identification of novel synthetic organic compounds with supersonic gas chromatography-mass spectrometry. J Chromatogr A 2004; 1058:233-42. [PMID: 15595673] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/01/2023]
Abstract
Several novel synthetic organic compounds were successfully analyzed with a unique type of GC-MS titled Supersonic GC-MS following a failure in their analysis with standard GC-MS. Supersonic GC-MS is based on interfacing GC and MS with a supersonic molecular beam (SMB) and on electron ionization of sample compounds as vibrationally cold molecules while in the SMB, or by cluster chemical ionization. The analyses of novel synthetic organic compounds significantly benefited from the extended range of compounds amenable to analyses with the Supersonic GC-MS. The Supersonic GC-MS enabled the analysis of thermally labile compounds that usually degrade in the GC injector, column and/or ion source. Due to the high carrier gas flow rate at the injector liner and column these compounds eluted without degradation at significantly lower elution temperatures and the use of fly-through EI ion source eliminated any sample degradation at the ion source. The cold EI feature of providing trustworthy enhanced molecular ion (M+), complemented by its optional further confirmation with cluster CI was highly valued by the synthetic organic chemists that were served by the Supersonic GC-MS. Furthermore, the provision of extended mass spectral structural, isomer and isotope information combined with short (a few minutes) GC-MS analysis times also proved beneficial for the analysis of unknown synthetic organic compounds. As a result, the synthetic organic chemists were provided with both qualitative and quantitative data on the composition of their synthetic mixture, and could better follow the path of their synthetic chemistry. Ten cases of such analyses are demonstrated in figures and discussed.
Collapse
Affiliation(s)
- Alexander B Fialkov
- School of Chemistry, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel
| | | |
Collapse
|
20
|
Abstract
Gas chromatography-mass spectrometry (GC-MS) suffers from a major limitation in that an expanding number of thermally labile or low volatility compounds of interest are not amenable for analysis. We found that the elution temperatures of compounds from GC can be significantly lowered by reducing the column length, increasing the carrier gas flow rate, reducing the capillary column film thickness and lowering the temperature programming rate. Pyrene is eluted at 287 degrees C in standard GC-MS with a 30 m x 0.25 mm I.D. column with 1-microm DB5ms film and 1-ml/min He column flow rate. In contrast, pyrene is eluted at 79 degrees C in our "Supersonic GC-MS" system using a 1 m x 0.25 mm I.D. column with 0.1-microm DB5ms film and 100-ml/min He column flow rate. A simple model has been invoked to explain the significantly (up to 208 degrees C) lower elution temperatures observed. According to this model, every halving of the temperature programming rate, or number of separation plates (either through increased flow rate or due to reduced column length), results in approximately 20 degrees C lower elution temperature. These considerably lower elution temperatures enable the analysis of an extended range of thermally labile and low volatility compounds, that otherwise could not be analyzed by standard GC-MS. We demonstrate the analysis of large polycyclic aromatic hydrocarbons (PAHs) such as decacyclene with ten fused rings, well above the current GC limit of PAHs with six rings. Even a metalloporphirin such as magnesiumoctaethylporphin was easily analyzed with elution temperatures below 300 degrees C. Furthermore, a range of thermally labile compounds were analyzed including carbamates such as methomyl, aldicarb, aldicarbsulfone and oxamyl, explosives such as pentaerythritol tetranitrate, Tetryl and HMX, and drugs such as reserpine (608 a.m.u.). Supersonic GC-MS was used, based on the coupling of a supersonic molecular beam (SMB) inlet and ion sources with a bench-top Agilent 6890 GC plus 5972 MSD. The Supersonic GC-MS provides enhanced molecular ion without any ion source related peak tailing. Thus, the lower GC separation power involved in the analysis of thermally labile and low volatility compounds is compensated by increased separation power of the MS gained from the enhanced molecular ion. Several implications of these findings are discussed, including our conclusion that slower chromatography leads to better analysis of thermally labile compounds.
Collapse
Affiliation(s)
- Alexander B Fialkov
- School of Chemistry, Sackler Faculty of Exact Sciences, Tel Aviv University, Ramat Aviv, Tel Aviv 69978 Israel
| | | | | |
Collapse
|
21
|
Fialkov AB, Amirav A. Cluster chemical ionization for improved confidence level in sample identification by gas chromatography/mass spectrometry. Rapid Commun Mass Spectrom 2003; 17:1326-1338. [PMID: 12811756 DOI: 10.1002/rcm.1057] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
Abstract
Upon the supersonic expansion of helium mixed with vapor from an organic solvent (e.g. methanol), various clusters of the solvent with the sample molecules can be formed. As a result of 70 eV electron ionization of these clusters, cluster chemical ionization (cluster CI) mass spectra are obtained. These spectra are characterized by the combination of EI mass spectra of vibrationally cold molecules in the supersonic molecular beam (cold EI) with CI-like appearance of abundant protonated molecules, together with satellite peaks corresponding to protonated or non-protonated clusters of sample compounds with 1-3 solvent molecules. Like CI, cluster CI preferably occurs for polar compounds with high proton affinity. However, in contrast to conventional CI, for non-polar compounds or those with reduced proton affinity the cluster CI mass spectrum converges to that of cold EI. The appearance of a protonated molecule and its solvent cluster peaks, plus the lack of protonation and cluster satellites for prominent EI fragments, enable the unambiguous identification of the molecular ion. In turn, the insertion of the proper molecular ion into the NIST library search of the cold EI mass spectra eliminates those candidates with incorrect molecular mass and thus significantly increases the confidence level in sample identification. Furthermore, molecular mass identification is of prime importance for the analysis of unknown compounds that are absent in the library. Examples are given with emphasis on the cluster CI analysis of carbamate pesticides, high explosives and unknown samples, to demonstrate the usefulness of Supersonic GC/MS (GC/MS with supersonic molecular beam) in the analysis of these thermally labile compounds. Cluster CI is shown to be a practical ionization method, due to its ease-of-use and fast instrumental conversion between EI and cluster CI, which involves the opening of only one valve located at the make-up gas path. The ease-of-use of cluster CI is analogous to that of liquid CI in ion traps with internal ionization, and is in marked contrast to that of CI with most other standard GC/MS systems that require a change of the ion source.
Collapse
Affiliation(s)
- Alexander B Fialkov
- School of Chemistry, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel
| | - Aviv Amirav
- School of Chemistry, Sackler Faculty of Exact Sciences, Tel Aviv University, Tel Aviv 69978, Israel
| |
Collapse
|