1
|
Patel AV, Stevens A, Shahzad H, Iyer AI, Ragland D, Cvetanovich G, Bishop JY, Rauck RC. The effect of allergies on outcomes following shoulder arthroplasty: A national database analysis of 154,478 patients. Shoulder Elbow 2024; 16:527-533. [PMID: 39493408 PMCID: PMC11528767 DOI: 10.1177/17585732231194615] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Accepted: 07/24/2023] [Indexed: 11/05/2024]
Abstract
Background The objective of this study is to investigate the effect of allergies on complications following total shoulder arthroplasty (TSA). Materials and Methods All data were collected by using the PearlDiver national database to identify patients who had undergone TSA (anatomic or reverse) between 1 January 2010 and 31 October 2021. Patients were stratified into two groups: allergies and no allergies. Comparisons were made regarding complications and revision surgeries. Complications were compared at 30 and 90 days. Revisions were compared at 1, 5 and 10 years postoperatively. Results This study identified 28,182 patients with allergies and 126,296 patients without allergies. Patients with allergies were more likely to require revision surgery at all time points analyzed (p < 0.001). Patients with allergies were more likely to have sepsis within 30 (OR 1.53 [1.30-1.80], p < 0.001) and 90 days (1.71 [1.51-1.94], p < 0.001) postoperatively. Patients with allergies were more likely to experience a wound complication within 30 (1.89 [1.58-2.26], p < 0.001) and 90 days (1.81 [1.58-2.08], p < 0.001). The allergy group experienced higher rates of prosthetic joint infections (PJI) (2.14 [1.81-2.54], p < 0.001) and implant complications at 90 days (1.52 [1.42-1.62], p < 0.001). Discussion Patients with allergies were more likely to require revision surgery, experience wound complications, sepsis and PJI following TSA.
Collapse
Affiliation(s)
- Akshar V Patel
- Department of Orthopaedics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Andrew Stevens
- Department of Orthopaedics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Hania Shahzad
- Department of Orthopaedics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Amogh I Iyer
- Department of Orthopaedics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Dashaun Ragland
- Department of Orthopaedics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Gregory Cvetanovich
- Department of Orthopaedics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Julie Y Bishop
- Department of Orthopaedics, The Ohio State University College of Medicine, Columbus, OH, USA
| | - Ryan C Rauck
- Department of Orthopaedics, The Ohio State University College of Medicine, Columbus, OH, USA
| |
Collapse
|
2
|
Morgan AM, Li ZI, Garra S, Bi AS, Gonzalez-Lomas G, Jazrawi LM, Campbell KA. Patient-reported allergies are associated with increased rate of postoperative stiffness after arthroscopic rotator cuff repair. J Shoulder Elbow Surg 2024; 33:1050-1057. [PMID: 37839628 DOI: 10.1016/j.jse.2023.09.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 08/29/2023] [Accepted: 09/03/2023] [Indexed: 10/17/2023]
Abstract
BACKGROUND Several risk factors have been identified for the development of postoperative shoulder stiffness, and there has been increasing interest in orthopedic literature regarding patient-reported allergy (PRA) as an identifiable risk factor for adverse outcomes. The purpose of this study is to determine whether PRAs are associated with subsequent rates of diagnosis of adhesive capsulitis (AC) or return to the operating room for postoperative shoulder stiffness within 2 years after arthroscopic rotator cuff repair (ARCR). METHODS Current Procedural Terminology surgical billing codes were used to retrospectively identify patients who underwent ARCR at a single urban academic institution from January 2012 to December 2020 with minimum 2-year follow-up. Lysis of adhesions (LOA), manipulation under anesthesia (MUA), and AC of the shoulder were further queried within 2 years postoperatively for the ipsilateral shoulder. Patients were excluded if they had undergone ipsilateral MUA/LOA or received a diagnosis of AC before the index procedure. Demographic characteristics and medical comorbidities (hypertension, diabetes, hyperlipidemia, and hypothyroidism) were extracted from electronic medical records. Baseline characteristics were compared between patients with and without PRAs. Multivariate logistic regression analyses were performed to determine the association of the presence of PRAs overall, as well as the presence of 1, 2, or 3 or more PRAs, with subsequent MUA/LOA or diagnosis of AC within 2 years postoperatively. RESULTS Of 7057 patients identified in the study period, 6583 were eligible for the final analysis. The mean age was 56.6 ± 11.7 years, and the mean body mass index was 29.1 ± 5.6. Overall, 19.3% of patients (n = 1271) reported at least 1 allergy, and 7.1% (n = 469) had >1 PRA. A total of 44 patients (0.7%) underwent subsequent ipsilateral MUA/LOA within 2 years postoperatively, whereas 93 patients (1.4%) received a diagnosis of ipsilateral AC in the same time frame. PRAs were significantly associated with subsequent diagnosis of AC (odds ratio [OR]: 2.39; 95% confidence interval [CI]: 1.45-3.92; P < .001), but not MUA/LOA (OR: 1.97, 95% CI: 1.26-3.61; P = .133). Patients with 2 PRAs had greater odds of being diagnosed with AC than patients with 1 PRA (OR: 2.74; 95% CI: 1.14-5.99; P = .012). Although this association was nonsignificant for MUA/LOA, patients with 2 PRAs (OR: 2.67; 95% CI: 0.96-8.80; P = .059) demonstrated a similar statistical trend. CONCLUSION PRAs are associated with increased odds of receiving a diagnosis of AC within 2 years after ARCR but were not found to be associated with return to the operating room for postoperative stiffness.
Collapse
Affiliation(s)
- Allison M Morgan
- Department of Orthopedic Surgery, New York University Langone Health, New York, NY, USA.
| | - Zachary I Li
- Department of Orthopedic Surgery, New York University Langone Health, New York, NY, USA
| | - Sharif Garra
- Department of Orthopedic Surgery, New York University Langone Health, New York, NY, USA
| | - Andrew S Bi
- Department of Orthopedic Surgery, New York University Langone Health, New York, NY, USA
| | | | - Laith M Jazrawi
- Department of Orthopedic Surgery, New York University Langone Health, New York, NY, USA
| | - Kirk A Campbell
- Department of Orthopedic Surgery, New York University Langone Health, New York, NY, USA
| |
Collapse
|
3
|
Palosaari AA, White CA, Gross BD, Patel A, Li T, Flatow EL, Cagle PJ. Effect of patient-reported allergies on reverse total shoulder arthroplasty outcomes at over two years follow-up. J Orthop 2024; 51:87-90. [PMID: 38357439 PMCID: PMC10862396 DOI: 10.1016/j.jor.2024.01.018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2023] [Revised: 01/29/2024] [Accepted: 01/30/2024] [Indexed: 02/16/2024] Open
Abstract
Background/aims Understanding the factors that lead to poor outcomes after reverse total shoulder arthroplasty (rTSA) is important to appropriate patient counseling. While patient-reported allergies (PRAs) have been shown to be associated with poorer outcomes after both TKA and THA, their effect on rTSA outcomes remains unclear. This study investigated the effect of zero, one, and two or more preoperative PRAs on clinical outcomes after rTSA at over two years follow-up in a cohort of fifty-two patients from our institution. Methods Patients who underwent rTSA and had a minimum follow-up time of two years were identified from an institutional database. Patients were split into cohorts of zero, one, and two or more PRAs. Range of motion (ROM) was assessed by degrees of forward elevation, external rotation, and internal rotation. Patient-reported outcomes (PROs) were assessed by the Visual Analog Scale (VAS), American Shoulder and Elbow Surgeon (ASES) score, and Simple Shoulder Test (SST) score. Results Fifty-two patients, 10 of whom reported one allergy and 11 of whom reported two or more allergies, were included in our analysis. Mean ROM and PROs improved after rTSA in each cohort. Differences in ROM and PROs between cohorts did not reach statistical significance; however, patients with PRAs tended to have worse preoperative forward elevation, VAS score, and ASES score. Two patients in the zero-allergy cohort required revision (6 %). Conclusion This study found no statistically significant difference in clinical outcomes among cohorts of patients with zero, one, or two or more preoperative PRAs after rTSA at over two years follow-up. However, patients with PRAs tended to have lower preoperative functional scores. We postulate that this may be the result of psychosomatic factors at play in these patients. PRAs should not dissuade patients or clinicians from pursuing rTSA.
Collapse
Affiliation(s)
- Andrew A. Palosaari
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, 425 West 59th Street, New York City, NY, USA
| | - Christopher A. White
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, 425 West 59th Street, New York City, NY, USA
| | - Benjamin D. Gross
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, 425 West 59th Street, New York City, NY, USA
| | - Akshar Patel
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, 425 West 59th Street, New York City, NY, USA
| | - Troy Li
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, 425 West 59th Street, New York City, NY, USA
| | - Evan L. Flatow
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, 425 West 59th Street, New York City, NY, USA
| | - Paul J. Cagle
- Department of Orthopedic Surgery, Icahn School of Medicine at Mount Sinai, 425 West 59th Street, New York City, NY, USA
| |
Collapse
|
4
|
Chen A, Kurmis AP. Understanding immune-mediated cobalt/chromium allergy to orthopaedic implants: a meta-synthetic review. ARTHROPLASTY 2024; 6:1. [PMID: 38303027 PMCID: PMC10835847 DOI: 10.1186/s42836-023-00227-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2023] [Accepted: 12/12/2023] [Indexed: 02/03/2024] Open
Abstract
BACKGROUND The frequency of primary joint replacement surgery continues to increase worldwide. While largely considered biologically inert entities, an increasing body of evidence continues to validate a not insignificant incidence of allergic reactions to such implants. Little previous work has explored genuinely immune-mediated reactivity in this context. In the absence of a contemporary published summary on the topic, this paper explored the current state of understanding of cobalt/chromium allergy and proposes a patient management algorithm whereby such immune reactions are clinically suggested. METHODS A structured, systematic literature review was performed by following PRISMA search principles to provide an updated review of this area. RESULTS Thirty-six topic-related articles were identified, the majority reflecting lower tiers of scientific evidence with a lack of homogeneous quantitative data to facilitate valid cohort comparisons. Largely, the available literature represented small case series' or expert opinions. CONCLUSIONS Despite increasing clinical awareness and acknowledgement of true allergy to joint replacement components, this review highlighted that the evidence base underpinning the diagnosis and management of such patients is limited. Both patient-reported metal allergy or skin patch testing are grossly unreliable methods and show almost no correlation with true immune reactivity. Recent studies suggested a potential role for patient-specific in vitro cellular activation testing and/or targeted genetic testing when cobalt/chromium allergy is clinically suspected. However, while likely representing the contemporary "best available" approaches both can be costly undertakings, are not yet universally available, and still require broader validation in non-research settings before wider uptake can be championed.
Collapse
Affiliation(s)
- Arnold Chen
- School of Medicine, University of Adelaide, Adelaide, SA, 5000, Australia
| | - Andrew P Kurmis
- Discipline of Medical Specialties, University of Adelaide, Adelaide, SA, 5000, Australia.
- Department of Orthopaedic Surgery, Lyell McEwin Hospital, Elizabeth Vale, SA, 5112, Australia.
- College of Medicine & Public Health, Flinders University, Bedford Park, SA, 5042, Australia.
| |
Collapse
|
5
|
Pautasso A, Zorzolo I, Bellato E, Pellegrino P, Ferrario A, Pira E, Castoldi F. Allergic reaction and metal hypersensitivity after shoulder joint replacement. Musculoskelet Surg 2023; 107:55-68. [PMID: 34719773 PMCID: PMC10020248 DOI: 10.1007/s12306-021-00729-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Accepted: 09/17/2021] [Indexed: 06/13/2023]
Abstract
PURPOSE Metal ion release may cause local and systemic effects and induce hypersensitivity reactions. The aim of our study is first to determine if implant-related hypersensitivity correlates to patient symptoms or not; second, to assess the rate of hypersensitivity and allergies in shoulder arthroplasty. METHODS Forty patients with shoulder replacements performed between 2015 and 2017 were studied with minimum 2-year follow-up; no patient had prior metal implants. Each patient underwent radiographic and clinical evaluation using the Constant-Murley Score (CMS), 22 metal and cement haptens patch testing, serum and urine tests to evaluate 12 metals concentration, and a personal occupational medicine interview. RESULTS At follow-up (average 45 ± 10.7 months), the mean CMS was 76 ± 15.9; no clinical complications or radiographic signs of loosening were detected; two nickel sulfate (5%), 1 benzoyl peroxide (2.5%) and 1 potassium dichromate (2.5%) positive findings were found, but all these patients were asymptomatic. There was an increase in serum aluminum, urinary aluminum and urinary chromium levels of 1.74, 3.40 and 1.83 times the baseline, respectively. No significant difference in metal ion concentrations were found when patients were stratified according to gender, date of surgery, type of surgery, and type of implant. CONCLUSIONS Shoulder arthroplasty is a source of metal ion release and might act as a sensitizing exposure. However, patch test positivity does not seem to correlate to hypersensitivity cutaneous manifestations or poor clinical results. Laboratory data showed small constant ion release over time, regardless of gender, type of shoulder replacement and implant used. LEVELS OF EVIDENCE Level II.
Collapse
Affiliation(s)
- A. Pautasso
- University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - I. Zorzolo
- University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - E. Bellato
- Orthopaedic and Traumatology Department, San Luigi Gonzaga Hospital, University of Turin, Regione Gonzole 10, 10043 Orbassano, Italy
| | - P. Pellegrino
- Oncologic Orthopaedic Department, Orthopaedic and Trauma Center – Città della Salute e della Scienza, University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - A. Ferrario
- Occupational Medicine Division, Department of Public Health and Pediatric Sciences, Orthopaedic and Trauma Center – Città della Salute e della Scienza, University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - E. Pira
- University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
- Occupational Medicine Division, Department of Public Health and Pediatric Sciences, Orthopaedic and Trauma Center – Città della Salute e della Scienza, University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
| | - F. Castoldi
- University of Turin, Via Gianfranco Zuretti 29, 10126 Turin, Italy
- Orthopaedic and Traumatology Department, San Luigi Gonzaga Hospital, University of Turin, Regione Gonzole 10, 10043 Orbassano, Italy
| |
Collapse
|
6
|
Evaluation of the Painful Total Shoulder Arthroplasty. J Am Acad Orthop Surg 2023; 31:440-449. [PMID: 36853881 DOI: 10.5435/jaaos-d-22-01006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 01/29/2023] [Indexed: 03/01/2023] Open
Abstract
Despite the overall success of anatomic and reverse total shoulder arthroplasties (aTSA and rTSA), some patients continue to have or develop pain postoperatively. As the number of shoulder arthroplasties continues to increase in the United States, it is important that surgeons are able to recognize, diagnose, and treat the various pathologies. Some painful etiologies are specific to either aTSA or rTSA, and others can occur with both implant types. Infections, stiffness, neurologic syndromes, polyethylene wear, aseptic implant loosening, and metal allergies occur, regardless of implant choice. However, after an aTSA, subscapularis repair failure, superior rotator cuff tear, and joint overstuffing can result in shoulder pain. After a rTSA, specific causes of postoperative pain include instability, scapular notching, acromial or scapular spine fractures, subcoracoid pain, and neurologic injury. Regardless of the diagnosis, the surgeon must be methodical in the evaluation and, when appropriate, use blood work, advanced imaging studies, joint aspirations, shoulder arthroscopy, and nerve studies. Once diagnosed, appropriate treatment should be undertaken to resolve the cause of the pain or at least minimize the effect of the pain on the patient's outcome.
Collapse
|
7
|
Bi AS, Shankar DS, Vasavada KD, Fisher ND, Strauss EJ, Alaia MJ, Campbell KA. Increasing patient-reported allergies are not associated with pain, functional outcomes, or satisfaction following medial patellofemoral ligament reconstruction: a retrospective comparative cohort study. Knee Surg Relat Res 2022; 34:19. [PMID: 35382898 PMCID: PMC8981631 DOI: 10.1186/s43019-022-00147-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Accepted: 03/23/2022] [Indexed: 11/10/2022] Open
Abstract
Background Patient-reported allergies (PRAs) are often stigmatized as a potential nonmodifiable risk factor for increased pain and worse functional outcomes following surgery. However, there is a dearth of literature directly assessing the impact of PRAs on outcomes in sport surgeries such as medial patellofemoral ligament reconstruction (MPFLR). The purpose of our study was to determine whether PRAs were associated with worse outcomes following MPFLR. Methods We conducted a retrospective review of patients who underwent MPFLR at our institution from 2011 to 2019. Patients were included if they had at least 12 months of follow-up. PRAs were obtained from preoperative medical assessments and categorized by drug class. Demographic and perioperative data were obtained from electronic medical records. Postoperative outcomes were measured using a telephone survey and included recurrent instability, Visual analog scale (VAS) for pain, VAS for sports, Kujala score, MPFL-Return to Sport after Injury (MPFL-RSI) score, and overall satisfaction score. Multiple linear regression was used to determine association between PRAs and outcome measures, and p-values less than 0.05 were considered significant. Results The cohort included 141 MPFLR. Most patients were female (98, 70%) with an average age of 25 years (range 12–56 years). Average follow-up time was 47 months. Forty-seven patients (33%) reported at least one PRA. There were no significant differences in postoperative pain, functional outcomes, satisfaction, or return to sport between patients with or without PRAs (all p > 0.05). Absence of antibiotic PRAs was predictive of higher VAS (p < 0.007), but there were no other differences. There were no significant differences in outcomes between patients without PRAs, PRAs without a concomitant psychiatric disorder, or PRAs with a concomitant psychiatric disorder (all p > 0.05). Conclusions In conclusion, PRAs with or without concomitant psychiatric diagnoses are not associated with worse postoperative pain, functional outcomes, or satisfaction following MPFLR with allograft, dispelling common misconceptions that increased number of allergies or psychiatric diagnoses lead to inferior surgical outcomes. Presence of antibiotic allergies was associated with lower VAS postoperative pain score. Future research should investigate the relationship between PRAs and other surgeries in the field of sports medicine.
Collapse
|
8
|
Hagedorn JM, Pittelkow TP, Bendel MA, Moeschler SM, Orhurhu V, Sanchez-Sotelo J. The painful shoulder arthroplasty: appropriate work-up and review of interventional pain treatments. JSES REVIEWS, REPORTS, AND TECHNIQUES 2022; 2:269-276. [PMID: 37588877 PMCID: PMC10426573 DOI: 10.1016/j.xrrt.2022.04.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 08/18/2023]
Abstract
Shoulder arthroplasty is a successful surgical procedure for several conditions when patients become refractory to conservative management modalities. Unfortunately, some patients experience persistent chronic pain after shoulder arthroplasty. These individuals should undergo a comprehensive evaluation by an orthopedic surgeon to determine whether structural pathology is responsible for the pain and to decide whether reoperation is indicated. At times, a surgical solution does not exist. In these circumstances, a thorough and specific plan for the management of persistent chronic pain should be developed and instituted. In this article, we review common reasons for persistent pain after shoulder arthroplasty and outline the evaluation of the painful shoulder arthroplasty. We then provide a thorough review of interventional pain management strategies. Finally, we hypothesize developments in our field that might provide better outcomes in the future for patients suffering with chronic intractable pain after shoulder arthroplasty.
Collapse
Affiliation(s)
- Jonathan M. Hagedorn
- Corresponding author: Jonathan M. Hagedorn, MD, Department of Anesthesiology and Perioperative Medicine, Division of Pain Medicine, Mayo Clinic, Rochester, MN 55905, USA.
| | - Thomas P. Pittelkow
- Department of Anesthesiology and Perioperative Medicine, Division of Pain Medicine, Mayo Clinic, Rochester, MN, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Markus A. Bendel
- Department of Anesthesiology and Perioperative Medicine, Division of Pain Medicine, Mayo Clinic, Rochester, MN, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Susan M. Moeschler
- Department of Anesthesiology and Perioperative Medicine, Division of Pain Medicine, Mayo Clinic, Rochester, MN, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Vwaire Orhurhu
- Department of Anesthesiology and Perioperative Medicine, Division of Pain Medicine, Mayo Clinic, Rochester, MN, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| | - Joaquin Sanchez-Sotelo
- Department of Anesthesiology and Perioperative Medicine, Division of Pain Medicine, Mayo Clinic, Rochester, MN, USA
- Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
| |
Collapse
|
9
|
A Brief Insight to the Electrophoretic Deposition of PEEK-, Chitosan-, Gelatin-, and Zein-Based Composite Coatings for Biomedical Applications: Recent Developments and Challenges. SURFACES 2021. [DOI: 10.3390/surfaces4030018] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Electrophoretic deposition (EPD) is a powerful technique to assemble metals, polymer, ceramics, and composite materials into 2D, 3D, and intricately shaped implants. Polymers, proteins, and peptides can be deposited via EPD at room temperature without affecting their chemical structures. Furthermore, EPD is being used to deposit multifunctional coatings (i.e., bioactive, antibacterial, and biocompatible coatings). Recently, EPD was used to architect multi-structured coatings to improve mechanical and biological properties along with the controlled release of drugs/metallic ions. The key characteristics of EPD coatings in terms of inorganic bioactivity and their angiogenic potential coupled with antibacterial properties are the key elements enabling advanced applications of EPD in orthopedic applications. In the emerging field of EPD coatings for hard tissue and soft tissue engineering, an overview of such applications will be presented. The progress in the development of EPD-based polymeric or composite coatings, including their application in orthopedic and targeted drug delivery approaches, will be discussed, with a focus on the effect of different biologically active ions/drugs released from EPD deposits. The literature under discussion involves EPD coatings consisting of chitosan (Chi), zein, polyetheretherketone (PEEK), and their composites. Moreover, in vitro and in vivo investigations of EPD coatings will be discussed in relation to the current main challenge of orthopedic implants, namely that the biomaterial must provide good bone-binding ability and mechanical compatibility.
Collapse
|
10
|
Holkar K, Kale V, Ingavle G. Hydrogel-Assisted 3D Model to Investigate the Osteoinductive Potential of MC3T3-Derived Extracellular Vesicles. ACS Biomater Sci Eng 2021; 7:2687-2700. [PMID: 34018721 DOI: 10.1021/acsbiomaterials.1c00386] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Effective and rapid regeneration of bone defects often pose substantial challenges in severe accidental injuries and disabilities occurring due to diseases and/or advanced age, especially in patients having reduced tissue regeneration competence. The success of mesenchymal stromal cell (MSC)-based research strategies in improving bone regeneration was hampered not only due to the limited knowledge of therapeutic actions of MSCs but also due to difficulties as well as expenses related to cell manufacturing and time taken for ethical approvals for clinical use of living cells and engineered tissues. The recent trend indicated that there is a shift from the direct usage of MSCs toward the application of paracrine factors and extracellular vesicles (EVs) isolated from their MSC secretome in bone tissue regeneration. This shift has directed research into the development of "cell-free" therapeutics, which could be a better alternative due to its several advantages over the use of their parental MSCs. Furthermore, accumulating evidence suggested that the 3D microenvironment influences the paracrine effects of MSCs. Although the osteogenic role of EVs has been explored recently, the current study showed, for the first time, that encapsulation of EVs along with MC3T3 cells in a 3D hydrogel-assisted culture with a distinct porous microenvironment having meso and macro (0.05-200 μm) pore size distribution resulted in an improved osteogenic response in vitro. The present work was primarily focused on investigating the influence of EVs isolated under distinct priming conditions to enhance the osteogenic potential. In addition, in the current work, the osteogenic ability of different types of EVs (microvesicles and exosomes) and total EVs isolated at different time points was also examined when encapsulated with MC3T3 cells in an alginate gel. Using various biochemical assays, such as alkaline phosphatase (ALP) production and calcium secretion, it was observed that both microvesicles and exosomes collected from MC3T3 cells independently had osteogenic potential; however, their collective activity was found to be superior. We further showed that EVs induce an early osteogenic response in MC3T3 cells as indicated by ALP and calcium secretion at a much earlier time point, compared to the controls. Our data suggested that this 3D hydrogel-assisted system provides close proximity of cells and EVs, and thus, mimics the in vivo scenario, making it clinically useful for bone tissue engineering.
Collapse
Affiliation(s)
- Ketki Holkar
- Symbiosis Centre for Stem Cell Research (SCSCR), Symbiosis International (Deemed University), Pune 412115, India
| | - Vaijayanti Kale
- Symbiosis Centre for Stem Cell Research (SCSCR), Symbiosis International (Deemed University), Pune 412115, India
| | - Ganesh Ingavle
- Symbiosis Centre for Stem Cell Research (SCSCR), Symbiosis International (Deemed University), Pune 412115, India
| |
Collapse
|
11
|
Prosthetic Bearing Surfaces in Anatomic and Reverse Total Shoulder Arthroplasty. J Am Acad Orthop Surg 2021; 29:414-422. [PMID: 33443383 DOI: 10.5435/jaaos-d-20-00166] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Accepted: 12/06/2020] [Indexed: 02/01/2023] Open
Abstract
Total shoulder arthroplasty (TSA) and reverse TSA have provided an effective treatment for glenohumeral osteoarthritis; however, longevity of the procedure may be limited by osteolysis and polyethylene wear. In TSA, glenoid component failure occurs through several mechanisms, the most common being aseptic loosening and polyethylene wear. Newer bearing surfaces such as highly cross-linked ultra-high-molecular-weight polyethylene, vitamin E processing, ceramic heads, and pyrolytic carbon surfaces have shown improved wear characteristics in biomechanical and some early clinical studies. The purpose of this review is to provide a historical perspective and current state of the art of bearing surface technology in anatomic and reverse TSA.
Collapse
|
12
|
Atilla HA, Çevik HB, Akdoğan M, Aslan H. Self-reported metal hypersensitivity in patients undergoing unicondylar knee arthroplasty. J Clin Orthop Trauma 2020; 14:17-21. [PMID: 33680813 PMCID: PMC7919954 DOI: 10.1016/j.jcot.2020.10.002] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 09/20/2020] [Accepted: 10/01/2020] [Indexed: 01/16/2023] Open
Abstract
OBJECTIVES There is ongoing discussion about arthroplasty surgery of patients with metal hypersensitivity. The aim of this study was to compare the functional outcomes and eosinophil counts of unicondylar knee arthroplasty (UKA) patients with and without a history of metal hypersensitivity. METHODS A retrospective review was made of the medical records of 148 extremities of 140 consecutive patients who underwent primary UKA between January 2016 and December 2017. The patients who met the inclusion criteria were screened for history of metal hypersensitivity using a questionnaire. The functional outcomes of patients and eosinophil levels were evaluated immediately before and at 6 weeks after surgery. RESULTS The mean follow-up period was 37 months (range, 18-48 months). Of the total 128 patients, 13 (10.2%) reported a history of metal hypersensitivity before the operation. There was no statistically significant difference between patients with or without a history of metal hypersensitivity in respect of the functional outcomes or eosinophil counts (p > 0.05). CONCLUSIONS The results of this study showed that the functional outcomes of patients who underwent UKA using a standard alloy did not change between the groups who reported having or not having a history of metal hypersensitivity. Although the study also showed that the eosinophil counts decreased after surgery compared to the preoperative counts, there was no statistical relationship between the eosinophil count and functional outcomes or metal hypersensitivity history.
Collapse
|