1
|
In vitro hemodynamic performance of a blood pump for self-powered venous assist in univentricular hearts. Sci Rep 2024; 14:6941. [PMID: 38521832 PMCID: PMC10960831 DOI: 10.1038/s41598-024-57269-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2023] [Accepted: 03/15/2024] [Indexed: 03/25/2024] Open
Abstract
Univentricular heart anomalies represent a group of severe congenital heart defects necessitating early surgical intervention in infancy. The Fontan procedure, the final stage of single-ventricle palliation, establishes a serial connection between systemic and pulmonary circulation by channeling venous return to the lungs. The absence of the subpulmonary ventricle in this peculiar circulation progressively eventuates in failure, primarily due to chronic elevation in inferior vena cava (IVC) pressure. This study experimentally validates the effectiveness of an intracorporeally-powered venous ejector pump (VEP) in reducing IVC pressure in Fontan patients. The VEP exploits a fraction of aortic flow to create a jet-venturi effect for the IVC, negating the external power requirement and driveline infections. An invitro Fontan mock-up circulation loop is developed and the impact of VEP design parameters and physiological conditions is assessed using both idealized and patient-specific total cavopulmonary connection (TCPC) phantoms. The VEP performance in reducing IVC pressure exhibited an inverse relationship with the cardiac output and extra-cardiac conduit (ECC) size and a proportional relationship with the transpulmonary pressure gradient (TPG) and mean arterial pressure (MAP). The ideal VEP with fail-safe features provided an IVC pressure drop of 1.82 ± 0.49, 2.45 ± 0.54, and 3.12 ± 0.43 mm Hg for TPG values of 6, 8, and 10 mm Hg, respectively, averaged over all ECC sizes and cardiac outputs. Furthermore, the arterial oxygen saturation was consistently maintained above 85% during full-assist mode. These results emphasize the potential utility of the VEP to mitigate elevated venous pressure in Fontan patients.
Collapse
|
2
|
Anatomical Compliance of Cavopulmonary Assist Device Designs: A Virtual Fitting Study in Fontan Patients. ASAIO J 2023; 69:1016-1024. [PMID: 37902686 DOI: 10.1097/mat.0000000000002013] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/31/2023] Open
Abstract
Several device designs for cavopulmonary mechanical circulatory support (MCS) are under investigation, however, challenged by the Fontan population's heterogeneity in size, cardiovascular and thoracic anatomy. This study aimed to preclinically assess the anatomical compliance of proposed device designs in silico. Representative double- and single-outlet cavopulmonary assist device (CPAD) designs were virtually implanted into CT imaging data of 10 patients previously palliated with total cavopulmonary connection (TCPC) for functionally univentricular hearts. Anatomical device compatibility was characterized concerning pump proximity to cardiovascular, respiratory and thoracic structures, as well as pump in- and outflow graft configuration. In 10 Fontan patients with a median age of 10.4 years (interquartile range [IQR] 5.0-15.3 years) and a median body surface area of 1.09 m2 (IQR 0.76-1.28 m2), implantation of a double-outlet CPAD was feasible in 1 patient (10%). In all other, adverse device intersection with the trachea and (neo-)aorta, or posterior pulmonary artery outflow graft kinking were observed. A single-outlet design permitted enhanced device mobilization adapting to individual anatomical conditions, resulting in device fit in nine of 10 patients (90%). Despite vast anatomical variations among single ventricle patients, a single-outlet device design may provide intracorporeal cavopulmonary MCS to a broad spectrum of failing Fontan patients.
Collapse
|
3
|
Five decades of Fontan palliation: What have we learned? What should we expect? J Int Med Res 2023; 51:3000605231209156. [PMID: 37910851 PMCID: PMC10621298 DOI: 10.1177/03000605231209156] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 10/04/2023] [Indexed: 11/03/2023] Open
Abstract
The Fontan procedure is the final palliative surgery in a series of staged surgeries to reroute the systemic venous blood flow directly to the lungs, with the ventricle(s) pumping oxygenated blood to the body. Advances in medical and surgical techniques have improved patients' overall survival after the Fontan procedure. However, Fontan-associated chronic comorbidities are common. In addition to chronic cardiac dysfunction and arrhythmias, complications involving other organs such as the liver, lungs, intestine, lymphatic system, brain, and blood frequently occur. This narrative review focuses on the immediate and late consequences in children, pregnant women, and other adults with Fontan circulation. In addition, we describe the technical advancements that might change the way single-ventricle patients are managed in future.
Collapse
|
4
|
Passive performance evaluation and validation of a viscous impeller pump for subpulmonary fontan circulatory support. Sci Rep 2023; 13:12668. [PMID: 37542111 PMCID: PMC10403595 DOI: 10.1038/s41598-023-38559-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 07/11/2023] [Indexed: 08/06/2023] Open
Abstract
Patients with single ventricle defects undergoing the Fontan procedure eventually face Fontan failure. Long-term cavopulmonary assist devices using rotary pump technologies are currently being developed as a subpulmonary power source to prevent and treat Fontan failure. Low hydraulic resistance is a critical safety requirement in the event of pump failure (0 RPM) as a modest 2 mmHg cavopulmonary pressure drop can compromise patient hemodynamics. The goal of this study is therefore to assess the passive performance of a viscous impeller pump (VIP) we are developing for Fontan patients, and validate flow simulations against in-vitro data. Two different blade heights (1.09 mm vs 1.62 mm) and a blank housing model were tested using a mock circulatory loop (MCL) with cardiac output ranging from 3 to 11 L/min. Three-dimensional flow simulations were performed and compared against MCL data. In-silico and MCL results demonstrated a pressure drop of < 2 mmHg at a cardiac output of 7 L/min for both blade heights. There was good agreement between simulation and MCL results for pressure loss (mean difference - 0.23 mmHg 95% CI [0.24-0.71]). Compared to the blank housing model, low wall shear stress area and oscillatory shear index on the pump surface were low, and mean washout times were within 2 s. This study demonstrated the low resistance characteristic of current VIP designs in the failed condition that results in clinically acceptable minimal pressure loss without increased washout time as compared to a blank housing model under normal cardiac output in Fontan patients.
Collapse
|
5
|
In Silico Evaluation of a Self-powered Venous Ejector Pump for Fontan Patients. Cardiovasc Eng Technol 2023; 14:428-446. [PMID: 36877450 PMCID: PMC10412470 DOI: 10.1007/s13239-023-00663-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/06/2022] [Accepted: 02/06/2023] [Indexed: 03/07/2023]
Abstract
PURPOSE The Fontan circulation carries a dismal prognosis in the long term due to its peculiar physiology and lack of a subpulmonic ventricle. Although it is multifactorial, elevated IVC pressure is accepted to be the primary cause of Fontan's high mortality and morbidity. This study presents a self-powered venous ejector pump (VEP) that can be used to lower the high IVC venous pressure in single-ventricle patients. METHODS A self-powered venous assist device that exploits the high-energy aortic flow to lower IVC pressure is designed. The proposed design is clinically feasible, simple in structure, and is powered intracorporeally. The device's performance in reducing IVC pressure is assessed by conducting comprehensive computational fluid dynamics simulations in idealized total cavopulmonary connections with different offsets. The device was finally applied to complex 3D reconstructed patient-specific TCPC models to validate its performance. RESULTS The assist device provided a significant IVC pressure drop of more than 3.2 mm Hg in both idealized and patient-specific geometries, while maintaining a high systemic oxygen saturation of more than 90%. The simulations revealed no significant caval pressure rise (< 0.1 mm Hg) and sufficient systemic oxygen saturation (> 84%) in the event of device failure, demonstrating its fail-safe feature. CONCLUSIONS A self-powered venous assist with promising in silico performance in improving Fontan hemodynamics is proposed. Due to its passive nature, the device has the potential to provide palliation for the growing population of patients with failing Fontan.
Collapse
|
6
|
On the steady-state concentration and hydrodynamic fields close to a rotating hemispherical electrode with concentration dependent viscosity and diffusivity. Electrochim Acta 2023. [DOI: 10.1016/j.electacta.2023.142236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/17/2023]
|
7
|
Passive Performance Evaluation and Validation of a Viscous Impeller Pump for Subpulmonary Fontan Circulatory Support. RESEARCH SQUARE 2023:rs.3.rs-2584661. [PMID: 36909557 PMCID: PMC10002834 DOI: 10.21203/rs.3.rs-2584661/v1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/04/2023]
Abstract
Patients with single ventricle defects undergoing the Fontan procedure eventually face Fontan failure. Long-term cavopulmonary assist devices using rotary pump technologies are currently being developed as a subpulmonary power source to prevent and treat Fontan failure. Low hydraulic resistance is a critical safety requirement in the event of pump failure (0 RPM) as a modest 2 mmHg cavopulmonary pressure drop can compromise patient hemodynamics. The goal of this study is therefore to assess the passive performance for a viscous impeller pump (VIP) we are developing for Fontan patients, and validate flow simulations against in-vitro data. Two different blade heights (1.09 mm vs 1.62 mm) and a blank housing model were tested using a mock circulatory loop (MCL) with cardiac output ranging from 3 to 11 L/min. Three-dimensional flow simulations were performed and compared against MCL data. In-silico and MCL results demonstrated a clinically insignificant pressure drop of $<$ 2 mmHg at a cardiac output of 7 L/min for both blade heights. There was good agreement between simulation and MCL results for pressure loss (mean difference -0.23 mmHg 95% CI [0.24 -0.71]). Compared to the blank housing model, low wall shear stress area and oscillatory shear index on the pump surface were low, and mean washout times were within 2 seconds. This study demonstrated the low resistance characteristic of current VIP designs in the failed condition that results in clinically acceptable minimal pressure loss with low risk of thrombosis.
Collapse
|
8
|
Beyond CFD: Emerging methodologies for predictive simulation in cardiovascular health and disease. BIOPHYSICS REVIEWS 2023; 4:011301. [PMID: 36686891 PMCID: PMC9846834 DOI: 10.1063/5.0109400] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 12/12/2022] [Indexed: 01/15/2023]
Abstract
Physics-based computational models of the cardiovascular system are increasingly used to simulate hemodynamics, tissue mechanics, and physiology in evolving healthy and diseased states. While predictive models using computational fluid dynamics (CFD) originated primarily for use in surgical planning, their application now extends well beyond this purpose. In this review, we describe an increasingly wide range of modeling applications aimed at uncovering fundamental mechanisms of disease progression and development, performing model-guided design, and generating testable hypotheses to drive targeted experiments. Increasingly, models are incorporating multiple physical processes spanning a wide range of time and length scales in the heart and vasculature. With these expanded capabilities, clinical adoption of patient-specific modeling in congenital and acquired cardiovascular disease is also increasing, impacting clinical care and treatment decisions in complex congenital heart disease, coronary artery disease, vascular surgery, pulmonary artery disease, and medical device design. In support of these efforts, we discuss recent advances in modeling methodology, which are most impactful when driven by clinical needs. We describe pivotal recent developments in image processing, fluid-structure interaction, modeling under uncertainty, and reduced order modeling to enable simulations in clinically relevant timeframes. In all these areas, we argue that traditional CFD alone is insufficient to tackle increasingly complex clinical and biological problems across scales and systems. Rather, CFD should be coupled with appropriate multiscale biological, physical, and physiological models needed to produce comprehensive, impactful models of mechanobiological systems and complex clinical scenarios. With this perspective, we finally outline open problems and future challenges in the field.
Collapse
|
9
|
Use of 3D anatomical models in mock circulatory loops for cardiac medical device testing. Artif Organs 2023; 47:260-272. [PMID: 36370033 DOI: 10.1111/aor.14433] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/08/2022] [Revised: 08/16/2022] [Accepted: 10/11/2022] [Indexed: 11/13/2022]
Abstract
INTRODUCTION Mock circulatory loops (MCLs) are mechanical representations of the cardiovascular system largely used to test the hemodynamic performance of cardiovascular medical devices (MD). Thanks to 3 dimensional (3D) printing technologies, MCLs can nowadays also incorporate anatomical models so to offer enhanced testing capabilities. The aim of this review is to provide an overview on MCLs and to discuss the recent developments of 3D anatomical models for cardiovascular MD testing. METHODS The review first analyses the different techniques to develop 3D anatomical models, in both rigid and compliant materials. In the second section, the state of the art of MCLs with 3D models is discussed, along with the testing of different MDs: implantable blood pumps, heart valves, and imaging techniques. For each class of MD, the MCL is analyzed in terms of: the cardiovascular model embedded, the 3D model implemented (the anatomy represented, the material used, and the activation method), and the testing applications. DISCUSSIONS AND CONCLUSIONS MCLs serve the purpose of testing cardiovascular MDs in different (patho-)physiological scenarios. The addition of 3D anatomical models enables more realistic connections of the MD with the implantation site and enhances the testing capabilities of the MCL. Current attempts focus on the development of personalized MCLs to test MDs in patient-specific hemodynamic and anatomical scenarios. The main limitation of MCLs is the impossibility to assess the impact of a MD in the long-term and at a biological level, for which animal experiments are still needed.
Collapse
|
10
|
Mock circulatory loop applications for testing cardiovascular assist devices and in vitro studies. Front Physiol 2023; 14:1175919. [PMID: 37123281 PMCID: PMC10133581 DOI: 10.3389/fphys.2023.1175919] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 04/03/2023] [Indexed: 05/02/2023] Open
Abstract
The mock circulatory loop (MCL) is an in vitro experimental system that can provide continuous pulsatile flows and simulate different physiological or pathological parameters of the human circulation system. It is of great significance for testing cardiovascular assist device (CAD), which is a type of clinical instrument used to treat cardiovascular disease and alleviate the dilemma of insufficient donor hearts. The MCL installed with different types of CADs can simulate specific conditions of clinical surgery for evaluating the effectiveness and reliability of those CADs under the repeated performance tests and reliability tests. Also, patient-specific cardiovascular models can be employed in the circulation of MCL for targeted pathological study associated with hemodynamics. Therefore, The MCL system has various combinations of different functional units according to its richful applications, which are comprehensively reviewed in the current work. Four types of CADs including prosthetic heart valve (PHV), ventricular assist device (VAD), total artificial heart (TAH) and intra-aortic balloon pump (IABP) applied in MCL experiments are documented and compared in detail. Moreover, MCLs with more complicated structures for achieving advanced functions are further introduced, such as MCL for the pediatric application, MCL with anatomical phantoms and MCL synchronizing multiple circulation systems. By reviewing the constructions and functions of available MCLs, the features of MCLs for different applications are summarized, and directions of developing the MCLs are suggested.
Collapse
|
11
|
Computational Modeling of the Penn State Fontan Circulation Assist Device. ASAIO J 2022; 68:1513-1522. [PMID: 35421006 DOI: 10.1097/mat.0000000000001708] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
To address the increasing number of failing Fontan patients, Penn State University and the Penn State Hershey Medical Center are developing a centrifugal blood pump for long-term mechanical support. Computational fluid dynamics (CFD) modeling of the Penn State Fontan Circulatory Assist Device (FCAD) was performed to understand hemodynamics within the pump and its potential for hemolysis and thrombosis. CFD velocity and pressure results were first validated against experimental data and found to be within the standard deviations of the velocities and within 5% of the pressures. Further simulations performed with a human blood model found that most of the fluid domain was subjected to low shear stress (<50 Pa), with areas of highest stress around the rotor blade tips that increased with pump flow rate and rotor speed (138-178 Pa). However, the stresses compared well to previous CFD studies of commercial blood pumps and remained mostly below common thresholds of hemolysis and platelet activation. Additionally, few regions of low shear rate were observed within the FCAD, signifying minimal potential for platelet adhesion. These results further emphasize the FCAD's potential that has been observed previously in experimental and animal studies.
Collapse
|
12
|
Computational Investigation of Anastomosis Options of a Right-Heart Pump to Patient Specific Pulmonary Arteries. Ann Biomed Eng 2022; 50:929-940. [PMID: 35451680 DOI: 10.1007/s10439-022-02969-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 04/12/2022] [Indexed: 11/30/2022]
Abstract
Patients with Fontan circulation have increased risk of heart failure, but are not always candidates for heart transplant, leading to the development of the subpulmonic Penn State Fontan Circulation Assist Device. The aim of this study was to use patient-specific computational fluid dynamics simulations to evaluate anastomosis options for implanting this device. Simulations were performed of the pre-surgical anatomy as well as four surgical options: a T-junction and three Y-grafts. Cases were evaluated based on several fluid-dynamic quantities. The impact of imbalanced left-right pulmonary flow distribution was also investigated. Results showed that a 12-mm Y-graft was the most energy efficient. However, an 8-mm graft showed more favorable wall shear stress distribution, indicating lower risk of thrombosis and endothelial damage. The 8-mm Y-grafts also showed a more balanced pulmonary flow split, and lower residence time, also indicating lower thrombosis risk. The relative performance of the surgical options was largely unchanged whether or not the pulmonary vascular resistance remained imbalanced post-implantation.
Collapse
|
13
|
Current Treatment Options for the Failing Fontan Circulation. Curr Cardiol Rev 2022; 18:e060122200067. [PMID: 34994331 PMCID: PMC9893132 DOI: 10.2174/1573403x18666220106114518] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2020] [Revised: 10/22/2021] [Accepted: 11/16/2021] [Indexed: 11/22/2022] Open
Abstract
The Fontan operation was introduced in 1968. For congenital malformations, where biventricular repair is unsuitable, the Fontan procedure has provided a long-term palliation strategy with improved outcomes compared to the initially developed procedures. Despite these improvements, several complications merely due to a failing Fontan circulation, including myocardial dysfunction, arrhythmias, increased pulmonary vascular resistance, protein-losing enteropathy, hepatic dysfunction, plastic bronchitis, and thrombo-embolism, may occur, thereby limiting the life-expectancy in this patient cohort. This review provides an overview of the most common complications of Fontan circulation and the currently available treatment options.
Collapse
|
14
|
Experimental Hemodynamics within the Penn State Fontan Circulatory Assist Device. J Biomech Eng 2021; 144:1129243. [PMID: 34897373 DOI: 10.1115/1.4053210] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Indexed: 11/08/2022]
Abstract
For children born with a single functional ventricle, the Fontan operation bypasses the right ventricle by forming a four-way total cavopulmonary connection adapting the existing ventricle for the systemic circulation. However, upon adulthood, many Fontan patients exhibit low cardiac output and elevated venous pressure, eventually requiring a heart transplantation. Despite efforts to develop a Fontan pump or use an existing ventricular assist device for failing Fontan support, there is still no device designed or tested for subpulmonary support. Penn State University is developing a hydrodynamically levitated Fontan circulatory assist device (FCAD) for bridge-to-transplant or destination therapy. The FCAD hemodynamics, at both steady and pulsatile conditions for three pump operating conditions, were quantified using particle image velocimetry to determine the velocity magnitudes and Reynolds normal and shear stresses. Data were acquired at three planes (0 mm and ±25% of the radius) for the inferior and superior vena cavae inlets and the pulmonary artery outlet. The inlets had a blunt velocity profile that became skewed towards the collecting volute as fluid approached the rotor. At the outlet, regardless of the flow condition, a high-velocity jet exited the volute and moved downstream in a helical pattern. Turbulent stresses observed at the volute exit were influenced by the rotor's rotation. Regardless of inlet conditions, the pump demonstrated advantageous behavior for clinical use with a predictable flow field and a low risk of platelet adhesion and hemolysis based on calculated wall shear rates and turbulent stresses, respectively.
Collapse
|
15
|
Heart transplantation for patients with single ventricle physiology. Indian J Thorac Cardiovasc Surg 2021; 37:647-661. [PMID: 34642557 PMCID: PMC8495435 DOI: 10.1007/s12055-021-01241-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2021] [Revised: 07/12/2021] [Accepted: 07/13/2021] [Indexed: 11/29/2022] Open
Abstract
Background There is a growing population of palliated and unpalliated single ventricle physiology patients for whom heart transplantation is the only treatment option available. There is a paucity of reports of heart transplantation in this challenging and growing subset of patients from our part of the world. The purpose of the article is to briefly review our experience in the subgroup and compare it with the available literature. Methods This was a single-institution retrospective observational study of 16 patients with single ventricle physiology who were transplanted between 2016 and 2019 and their outcomes. The study groups were divided into those with ventricular dysfunction (group 1), who fare substantially better than those with normal ventricular function (group 2) whose short-term outcomes were poorer. Worsening cyanosis, poor candidature for completion Fontan procedure due to severe atrioventricular valve regurgitation or pulmonary artery anatomy, protein-losing enteropathy, plastic bronchitis, and worsening systemic venous congestion are indications in those with normal ventricular function. Results Patients with ventricular dysfunction as the main indication had excellent early survival with no early mortality compared to 40% mortality in patients with normal ventricular function. Patients who survived to leave the hospital had however similar long-term outcomes. Two patients with protein-losing enteropathy resolved completely by one month. Normal ventricular function, pulmonary artery stenting, early Fontan failure (6 months), ascites, and need for desensitization were risk factors for early mortality. After the early acute phase of increased risk, the mortality risk plateaued off. Conclusion Transplantation in patients with single ventricle and ventricular dysfunction can be offered with a good early and late outcome. There is a need to have multi-institutional and multi-disciplinary collaboration along with work in basic sciences to better understand the effects of failed Fontan physiology with normal ventricular function.
Collapse
|
16
|
Control strategy to enhance pulmonary vascular pulsatility for implantable cavopulmonary assist devices: A simulation study. Biomed Signal Process Control 2021. [DOI: 10.1016/j.bspc.2021.103008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
17
|
Commentary: First-Mover Advantage in the Quest for Cavopulmonary Circulatory Support. Semin Thorac Cardiovasc Surg 2021; 34:249-250. [PMID: 34242754 DOI: 10.1053/j.semtcvs.2021.06.030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 06/25/2021] [Indexed: 11/11/2022]
|
18
|
A Cavopulmonary Assist Device for Long-Term Therapy of Fontan Patients. Semin Thorac Cardiovasc Surg 2021; 34:238-248. [PMID: 34166811 DOI: 10.1053/j.semtcvs.2021.06.016] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Accepted: 06/04/2021] [Indexed: 12/22/2022]
Abstract
Treatment of univentricular hearts remains restricted to palliative surgical corrections (Fontan pathway). The established Fontan circulation lacks a subpulmonary pressure source and is commonly accompanied by progressively declining hemodynamics. A novel cavopulmonary assist device (CPAD) may hold the potential for improved therapeutic management of Fontan patients by chronic restoration of biventricular equivalency. This study aimed at translating clinical objectives toward a functional CPAD with preclinical proof regarding hydraulic performance, hemocompatibility and electric power consumption. A prototype composed of hemocompatible titanium components, ceramic bearings, electric motors, and corresponding drive unit was manufactured for preclinical benchtop analysis: hydraulic performance in general and hemocompatibility characteristics in particular were analyzed in-silico (computational fluid dynamics) and validated in-vitro. The CPAD's power consumption was recorded across the entire operational range. The CPAD delivered pressure step-ups across a comprehensive operational range (0-10 L/min, 0-50 mm Hg) with electric power consumption below 1.5 W within the main operating range. In-vitro hemolysis experiments (N = 3) indicated a normalized index of hemolysis of 3.8 ± 1.6 mg/100 L during design point operation (2500 rpm, 4 L/min). Preclinical investigations revealed the CPAD's potential for low traumatic and thrombogenic support of a heterogeneous Fontan population (pediatric and adult) with potentially accompanying secondary disorders (e.g., elevated pulmonary vascular resistance or systemic ventricular insufficiency) at distinct physical activities. The low power consumption implied adequate settings for a small, fully implantable system with transcutaneous energy transfer. The successful preclinical proof provides the rationale for acute and chronic in-vivo trials aiming at the confirmation of laboratory findings and verification of hemodynamic benefit.
Collapse
|
19
|
A sensorless physiologic control strategy for continuous flow cavopulmonary circulatory support devices. Biomed Signal Process Control 2020. [DOI: 10.1016/j.bspc.2020.102130] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
20
|
Anesthetic Considerations for Fontan-Associated Liver Disease and the Failing Fontan Circuit. J Cardiothorac Vasc Anesth 2020; 34:2224-2233. [PMID: 32249074 DOI: 10.1053/j.jvca.2020.02.040] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/16/2018] [Revised: 02/19/2020] [Accepted: 02/23/2020] [Indexed: 12/13/2022]
|
21
|
|
22
|
The failing Fontan. Indian J Thorac Cardiovasc Surg 2020; 37:82-90. [PMID: 33603286 DOI: 10.1007/s12055-020-00931-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2019] [Revised: 01/13/2020] [Accepted: 01/28/2020] [Indexed: 11/30/2022] Open
Abstract
Nearly 50 years back, Francis Fontan pioneered an operation for tricuspid atresia that bears his name today. The operation has since undergone numerous modifications and continues to be widely applied to an array of single ventricles. Despite restoring normal oxygen levels in the body, the operation creates a neoportal system where adequate cardiac output can be generated only at the expense of increased systemic venous congestion. This results in slow but relentless damage to the end organ systems especially the liver. Continuous surveillance of the patient to monitor this circulation, that will ultimately fail, is of paramount importance. Timely medical and cardiac catheterization and surgical intervention can extend the life span of Fontan patients. Ultimately a change of the hemodynamic circuit in the form of heart transplantation or ventricular assist device will be required to salvage the failing Fontan circuit.
Collapse
|
23
|
The Potential Impact and Timeline of Engineering on Congenital Interventions. Pediatr Cardiol 2020; 41:522-538. [PMID: 32198587 DOI: 10.1007/s00246-020-02335-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/15/2019] [Accepted: 02/22/2020] [Indexed: 10/24/2022]
Abstract
Congenital interventional cardiology has seen rapid growth in recent decades due to the expansion of available medical devices. Percutaneous interventions have become standard of care for many common congenital conditions. Unfortunately, patients with congenital heart disease often require multiple interventions throughout their lifespan. The availability of transcatheter devices that are biodegradable, biocompatible, durable, scalable, and can be delivered in the smallest sized patients will rely on continued advances in engineering. The development pipeline for these devices will require contributions of many individuals in academia and industry including experts in material science and tissue engineering. Advances in tissue engineering, bioresorbable technology, and even new nanotechnologies and nitinol fabrication techniques which may have an impact on the field of transcatheter congenital device in the next decade are summarized in this review. This review highlights recent advances in the engineering of transcatheter-based therapies and discusses future opportunities for engineering of transcatheter devices.
Collapse
|
24
|
Abstract
Single-ventricle physiology occurs in patients with hypoplastic ventricular heart defects, either on the right or left, who have undergone stepwise palliation surgeries ending with the Fontan procedure. After Fontan completion, these patients are dependent on passive venous return to the pulmonary circulation. The implications of passive flow are potentially devastating to the patient. We discuss some of the basic changes to the patient’s experience after a Fontan procedure, as well as the common complications. We also touch on some of the emerging management strategies for the common complications.
Collapse
|
25
|
Hemodynamic Effects of A Simplified Venturi Conduit for Fontan Circulation: A Pilot, In Silico Analysis. Sci Rep 2020; 10:817. [PMID: 31964953 PMCID: PMC6972950 DOI: 10.1038/s41598-020-57634-2] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2019] [Accepted: 12/31/2019] [Indexed: 12/28/2022] Open
Abstract
Objectives: To study the effects of a self-powered Fontan circulation in both idealized Fontan models and patient-specific models. Methods: In silico, a conduit with a nozzle was introduced from ascending aorta into the anastomosis of superior vena cava and pulmonary artery. Computational fluid dynamics (CFD) simulation was applied to calculate the fluid fields of models. Three 3-dimentional idealized models with different offsets were reconstructed by computer-aided design to evaluate the effects of the self-powered conduit. Furthermore, to validate the effects in patient-specific models, the conduit was introduced to three reconstructed models with different offsets. Results: The pressures at superior venae cavae and inferior venae cavae were decreased in both idealized models (0.4 mmHg) and patient-specific models (0.7 mmHg). In idealized models, the flows to left lungs were decreased (70%) by the jets from the conduits. However, in patient-specific models, the reductions of blood to the left lungs were relatively limited (30%) comparing to idealized models. Conclusions: CFD simulation was applied to analyze the effectiveness of the Fontan self-powered conduit. This self-powered conduit may help to decrease the venae cavae pressures and increase the flow to pulmonary arteries.
Collapse
|
26
|
Review on Mechanical Support and Cell-Based Therapies for the Prevention and Recovery of the Failed Fontan-Kreutzer Circulation. Front Pediatr 2020; 8:627660. [PMID: 33575233 PMCID: PMC7870783 DOI: 10.3389/fped.2020.627660] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Accepted: 12/31/2020] [Indexed: 12/13/2022] Open
Abstract
Though the current staged surgical strategy for palliation of single ventricle heart disease, culminating in a Fontan circulation, has increased short-term survival, mounting evidence has shown that the single ventricle, especially a morphologic right ventricle (RV), is inadequate for long-term circulatory support. In addition to high rates of ventricular failure, high central venous pressures (CVP) lead to liver fibrosis or cirrhosis, lymphatic dysfunction, kidney failure, and other comorbidities. In this review, we discuss the complications seen with Fontan physiology, including causes of ventricular and multi-organ failure. We then evaluate the clinical use, results, and limitations of long-term mechanical assist devices intended to reduce RV work and high CVP, as well as biological therapies for failed Fontan circulations. Finally, we discuss experimental tissue engineering solutions designed to prevent Fontan circulation failure and evaluate knowledge gaps and needed technology development to realize a more robust single ventricle therapy.
Collapse
|
27
|
Risks and Benefits of Using a Commercially Available Ventricular Assist Device for Failing Fontan Cavopulmonary Support: A Modeling Investigation. IEEE Trans Biomed Eng 2020; 67:213-219. [PMID: 30998452 DOI: 10.1109/tbme.2019.2911470] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
Fontan patients often develop circulatory failure and are in desperate need of a therapeutic solution. A blood pump surgically placed in the cavopulmonary pathway can substitute the function of the absent sub-pulmonary ventricle by generating a mild pressure boost. However, there is currently no commercially available device designed for the cavopulmonary application; and the risks and benefits of implanting a ventricular assist device (VAD), originally designed for the left ventricular application, on the right circulation of failing Fontan patients is not yet clear. Moreover, further research is needed to compare the hemodynamics between the two clinically-considered surgical configurations for cavopulmonary assist, with Full and inferior vena cava (IVC) support corresponding to the entire venous return or only the inferior venous return, respectively, being routed through the VAD. In this study, we used a numerical model of the failing Fontan physiology to evaluate the Fontan hemodynamic response to a left VAD during the IVC and Full support scenarios. We observed that during Full support, the VAD improved the cardiac output while maintaining blood pressures within safe ranges, and lowered the IVC pressure to <15 mmHg; however, we found a potential risk of lung damage at higher pump speeds due to the excessive pulmonary pressure elevation. IVC support, on the other hand, did not benefit the hemodynamics in the patient cases simulated, resulting in the superior vena cava pressure increasing to an unsafe level of >20 mmHg. The findings in this study may be helpful to surgeons for recognizing the risks of a cavopulmonary VAD and developing coherent clinical strategies for the implementation of cavopulmonary support.
Collapse
|
28
|
|
29
|
Cavopulmonary assist: Long-term reversal of the Fontan paradox. J Thorac Cardiovasc Surg 2019; 158:1627-1636. [PMID: 31564543 DOI: 10.1016/j.jtcvs.2019.06.112] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2019] [Revised: 06/13/2019] [Accepted: 06/14/2019] [Indexed: 01/16/2023]
Abstract
OBJECTIVE Fontan circulatory inefficiency can be addressed by replacing the missing subpulmonary power source to reverse the Fontan paradox. An implantable cavopulmonary assist device is described that will simultaneously reduce systemic venous pressure and increase pulmonary arterial pressure, improving preload and cardiac output, in a univentricular Fontan circulation on a long-term basis. METHODS A rotary blood pump that was based on the von Karman viscous pump was designed for implantation into the total cavopulmonary connection (TCPC). It will impart modest pressure energy to augment Fontan flow without risk of obstruction. In the event of rotational failure, it is designed to default to a passive flow diverter. Pressure-flow performance was characterized in vitro in a Fontan mock circulatory loop with blood analog. RESULTS The pump performed through the fully specified operating range, augmenting flow in all 4 directions of the TCPC. Pressure rise of 6 to 8 mm Hg was readily achieved, ranging to 14 mm Hg at highest speed (5600 rpm). Performance was consistent across a wide range of cardiac outputs. In stalled condition (0 rpm), there was no discernible pressure loss across the TCPC. CONCLUSIONS A blood pump technology is described that can reverse the Fontan paradox and may permit a surgical strategy of long-term biventricular maintenance of a univentricular Fontan circulation. The technology is intended for Fontan failure in which right-sided circulatory inefficiencies predominate and ventricular systolic function is preserved. It may also apply before clinical Fontan failure as health maintenance to preempt the progression of Fontan disease.
Collapse
|
30
|
Evaluation and Management of the Child and Adult With Fontan Circulation: A Scientific Statement From the American Heart Association. Circulation 2019; 140:e234-e284. [PMID: 31256636 DOI: 10.1161/cir.0000000000000696] [Citation(s) in RCA: 393] [Impact Index Per Article: 78.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
It has been 50 years since Francis Fontan pioneered the operation that today bears his name. Initially designed for patients with tricuspid atresia, this procedure is now offered for a vast array of congenital cardiac lesions when a circulation with 2 ventricles cannot be achieved. As a result of technical advances and improvements in patient selection and perioperative management, survival has steadily increased, and it is estimated that patients operated on today may hope for a 30-year survival of >80%. Up to 70 000 patients may be alive worldwide today with Fontan circulation, and this population is expected to double in the next 20 years. In the absence of a subpulmonary ventricle, Fontan circulation is characterized by chronically elevated systemic venous pressures and decreased cardiac output. The addition of this acquired abnormal circulation to innate abnormalities associated with single-ventricle congenital heart disease exposes these patients to a variety of complications. Circulatory failure, ventricular dysfunction, atrioventricular valve regurgitation, arrhythmia, protein-losing enteropathy, and plastic bronchitis are potential complications of the Fontan circulation. Abnormalities in body composition, bone structure, and growth have been detected. Liver fibrosis and renal dysfunction are common and may progress over time. Cognitive, neuropsychological, and behavioral deficits are highly prevalent. As a testimony to the success of the current strategy of care, the proportion of adults with Fontan circulation is increasing. Healthcare providers are ill-prepared to tackle these challenges, as well as specific needs such as contraception and pregnancy in female patients. The role of therapies such as cardiovascular drugs to prevent and treat complications, heart transplantation, and mechanical circulatory support remains undetermined. There is a clear need for consensus on how best to follow up patients with Fontan circulation and to treat their complications. This American Heart Association statement summarizes the current state of knowledge on the Fontan circulation and its consequences. A proposed surveillance testing toolkit provides recommendations for a range of acceptable approaches to follow-up care for the patient with Fontan circulation. Gaps in knowledge and areas for future focus of investigation are highlighted, with the objective of laying the groundwork for creating a normal quality and duration of life for these unique individuals.
Collapse
|
31
|
Chronic In Vivo Test of a Right Heart Replacement Blood Pump for Failed Fontan Circulation. ASAIO J 2019; 65:593-600. [DOI: 10.1097/mat.0000000000000888] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|
32
|
A long-term mechanical cavopulmonary support device for patients with Fontan circulation. Med Eng Phys 2019; 70:9-18. [DOI: 10.1016/j.medengphy.2019.06.017] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Revised: 06/15/2019] [Accepted: 06/19/2019] [Indexed: 12/28/2022]
|
33
|
Abstract
Long-term mechanical circulatory support (LT-MCS) is an important treatment modality for patients with severe heart failure. Different devices are available, and many-sometimes contradictory-observations regarding patient selection, surgical techniques, perioperative management and follow-up have been published. With the growing expertise in this field, the European Association for Cardio-Thoracic Surgery (EACTS) recognized a need for a structured multidisciplinary consensus about the approach to patients with LT-MCS. However, the evidence published so far is insufficient to allow for generation of meaningful guidelines complying with EACTS requirements. Instead, the EACTS presents an expert opinion in the LT-MCS field. This expert opinion addresses patient evaluation and preoperative optimization as well as management of cardiac and non-cardiac comorbidities. Further, extensive operative implantation techniques are summarized and evaluated by leading experts, depending on both patient characteristics and device selection. The faculty recognized that postoperative management is multidisciplinary and includes aspects of intensive care unit stay, rehabilitation, ambulatory care, myocardial recovery and end-of-life care and mirrored this fact in this paper. Additionally, the opinions of experts on diagnosis and management of adverse events including bleeding, cerebrovascular accidents and device malfunction are presented. In this expert consensus, the evidence for the complete management from patient selection to end-of-life care is carefully reviewed with the aim of guiding clinicians in optimizing management of patients considered for or supported by an LT-MCS device.
Collapse
|
34
|
Heart Failure in Adult Congenital Heart Disease: From Advanced Therapies to End-of-Life Care. Can J Cardiol 2019; 35:1723-1739. [PMID: 31813505 DOI: 10.1016/j.cjca.2019.07.626] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2019] [Revised: 07/12/2019] [Accepted: 07/23/2019] [Indexed: 12/14/2022] Open
Abstract
There is mounting recognition that some of the most urgent problems of adult congenital heart disease (ACHD) are the prevention, diagnosis, and management of heart failure (HF). Recent expert consensus and position statements not only emphasize a specific and pressing need to tackle HF in ACHD (ACHD-HF) but also highlight the difficulty of doing so given a current sparsity of data. Some of the challenges will be addressed by this review. The authors are from 3 different centres; each centre has an established subspeciality ACHD-HF clinic and is able to provide heart transplant, multiorgan transplant, and mechanical support for patients with ACHD. Appropriate care of this complex population requires multidisciplinary ACHD-HF teams evaluate all possible treatment options. The risks and benefits of nontransplant ACHD surgery, percutaneous structural and electrophysiological intervention, and ongoing conservative management must be considered alongside those of transplant strategies. In our approach, advanced care planning and palliative care coexist with the consideration of advanced therapies. An ethos of shared decision making, guided by the patient's values and preferences, strengthens clinical care, but requires investment of time as well as skilled communication. In this review, we aim to offer practical real-world advice for managing these patients, supported by scientific data where it exists.
Collapse
|
35
|
Computational fluid dynamic simulations of a cavopulmonary assist device for failing Fontan circulation. J Thorac Cardiovasc Surg 2019; 158:1424-1433.e5. [PMID: 31005303 DOI: 10.1016/j.jtcvs.2019.03.008] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2018] [Revised: 01/13/2019] [Accepted: 03/02/2019] [Indexed: 01/23/2023]
Abstract
OBJECTIVES Adult patients who have undergone the Fontan procedure are highly vulnerable to gradual, progressive circulatory failure, and options to reverse this situation are few. A cavopulmonary assist device could decongest the venous and lymphatic systems, overcome elevated pulmonary vascular resistance, increase cardiac output, and support some of these patients to heart transplant. This study characterizes the performance and challenges of a novel multilumen cannula coupled to an external blood pump proposed as a potential Fontan cavopulmonary assist strategy. METHODS Computational fluid dynamic simulations were conducted for 3 extracardiac Fontan geometries consisting of 1 idealized model and 2 patient-specific models. A range of physiologic flow rates and pump assist levels were simulated to calculate the pressure gain provided by the multilumen cannula. Hemolysis index was estimated for the idealized model with Lagrangian particle tracking and 2 variations of the power-law. Wall shear stresses were also examined. RESULTS Pressure gains up to 4 and 9 mm Hg were achieved for the idealized and patient-specific models, respectively. Pressure gains increased with both higher cardiac output and larger pump intake through the external pump. Flow-weighted hemolysis show hemoglobin damage levels to be several times lower than the 2% threshold at the highest pump intake flow cases. Wall shear stress predictions depict elevated areas in the pulmonary vessels and regions of the cannula device. CONCLUSIONS The cannula tested in this study shows promise as a percutaneous option to bridge support in some patients with a failing extracardiac Fontan. Limitations identified will be addressed in future design iterations and in ongoing experimental tests.
Collapse
|
36
|
Dual-Propeller Cavopulmonary Pump for Assisting Patients with Hypoplastic Right Ventricle. ASAIO J 2019; 65:888-897. [PMID: 30688694 DOI: 10.1097/mat.0000000000000907] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Various congenital heart defects (CHDs) are characterized by the existence of a single functional ventricle, which perfuses both the systemic and pulmonary circulation. A three-stage palliation procedure, including the final Fontan completion, is often adopted by surgeons to treat patients with such CHDs. The completion Fontan involves the creation of a total cavopulmonary connection (TCPC), commonly accomplished with an extracardiac conduit. This TCPC results in nonphysiologic flow conditions that can lead to systemic venous hypertension, reduced cardiac output, and ultimately the need for heart transplantation. A modest pressure rise of 5-6 mm Hg could correct the abnormal flow dynamics in these patients. To achieve this, we propose a novel conceptual design of a dual-propeller pump inside a flared TCPC. The TCPC dual-propeller conjunction was examined for hydraulic performance, blood flow pattern, and potential for hemolysis inside the TCPC using computational fluid dynamics (CFD). The effect of axial distance between the two propellers on the blood flow interference and energy loss was studied to determine the optimal separation distance. Both the inferior vena cava (IVC) and superior vena cava (SVC) propellers provided a pressure rise of 1-20 mm Hg at flow rates ranging from 0.4 to 7 lpm while rotating at speeds of 6,000-12,000 rpm. Larger separation distance provided favorable performance in terms of flow interference, energy loss, and blood damage potential. The ability of a dual-propeller micropump to provide the required pressure rise would help to augment the cavopulmonary flow and mimic flows seen in normal biventricular circulation.
Collapse
|
37
|
Approaches to Establish Extracardiac Total Cavopulmonary Connections in Animal Models—A Review. World J Pediatr Congenit Heart Surg 2019; 10:81-89. [DOI: 10.1177/2150135118802788] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Background: Long-term survival of patients with a single ventricle palliated with a Fontan procedure is still limited. No curative treatment options are available. To investigate the pathophysiology and potential treatment options, such as mechanical circulatory support (MCS), appropriate large animal models are required. The aim of this review was to analyze all full-text manuscripts presenting approaches for an extracardiac total cavopulmonary connection (TCPC) animal model to identify the feasibility and limitations in the acute and chronic setting. Methods: A literature search was performed for full-text publications presenting large animal models with extracardiac TCPCs on Pubmed and Embase. Out of 454 reviewed papers, 23 manuscripts fulfilled the inclusion criteria. Surgical procedures were categorized and hemodynamic changes at the transition from the biventricular to the univentricular condition analyzed. Results: Surgical procedures varied especially regarding coronary venous flow handling and anatomic shape of the TCPC. In most studies (n = 14), the main pulmonary artery was clamped and the coronary venous flow redirected by additional surgical interventions. Only in five reports, the caval veins were connected to the right pulmonary artery to create a true TCPC shape, whereas in all others (n = 18), the veins were connected to the main pulmonary artery. An elevated pulmonary vascular resistance was identified as a limiting hemodynamic factor for TCPC completion in healthy animals. Conclusions: A variety of acute TCPC animal models were successfully established with and without MCS, reflecting the most important hemodynamic features of a Fontan circulation; however, chronic animal models were not reported.
Collapse
|
38
|
Failing Fontan assist: From tissue to turbine. J Thorac Cardiovasc Surg 2018; 156:1947-1948. [PMID: 30336923 DOI: 10.1016/j.jtcvs.2018.08.060] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/26/2018] [Accepted: 08/27/2018] [Indexed: 11/25/2022]
|
39
|
A Versatile Hybrid Mock Circulation for Hydraulic Investigations of Active and Passive Cardiovascular Implants. ASAIO J 2018; 65:495-502. [PMID: 30045051 PMCID: PMC6615934 DOI: 10.1097/mat.0000000000000851] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023] Open
Abstract
Supplemental Digital Content is available in the text. During the development process of active or passive cardiovascular implants, such as ventricular assist devices or vascular grafts, extensive in-vitro testing is required. The aim of the study was to develop a versatile hybrid mock circulation (HMC) which can support the development of such implants that have a complex interaction with the circulation. The HMC operates based on the hardware-in-the-loop concept with a hydraulic interface of four pressure-controlled reservoirs allowing the interaction of the implant with a numerical model of the cardiovascular system. Three different conditions were investigated to highlight the versatility and the efficacy of the HMC during the development of such implants: 1) biventricular assist device (BiVAD) support with progressive aortic valve insufficiency, 2) total artificial heart (TAH) support with increasing pulmonary vascular resistance, and 3) flow distribution in a total cavopulmonary connection (TCPC) in a Fontan circulation during exercise. Realistic pathophysiologic waveforms were generated with the HMC and all hemodynamic conditions were simulated just by adapting the software. The results of the experiments indicated the potential of physiologic control during BiVAD or TAH support to prevent suction or congestion events, which may occur during constant-speed operation. The TCPC geometry influenced the flow distribution between the right and the left pulmonary artery, which was 10% higher in the latter and led to higher pressures. Together with rapid prototyping methods, the HMC may enhance the design of implants to achieve better hemodynamics. Validation of the models with clinical recordings is suggested for increasing the reliability of the HMC.
Collapse
|
40
|
The Fontan circulation: Time for a moon shot? J Thorac Cardiovasc Surg 2018; 156:252-253. [DOI: 10.1016/j.jtcvs.2017.12.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/27/2017] [Accepted: 12/04/2017] [Indexed: 11/18/2022]
|
41
|
Mechanical circulatory support challenges in pediatric and (adult) congenital heart disease. Curr Opin Organ Transplant 2018; 23:301-307. [DOI: 10.1097/mot.0000000000000522] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
42
|
Progress in experimental and clinical subpulmonary assistance for Fontan circulation. J Thorac Cardiovasc Surg 2018; 156:1949-1956. [PMID: 29884497 DOI: 10.1016/j.jtcvs.2018.04.102] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2017] [Revised: 04/09/2018] [Accepted: 04/24/2018] [Indexed: 11/15/2022]
|
43
|
In vitro validation of a self-driving aortic-turbine venous-assist device for Fontan patients. J Thorac Cardiovasc Surg 2018; 156:292-301.e7. [PMID: 29666009 PMCID: PMC6021195 DOI: 10.1016/j.jtcvs.2018.02.088] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/26/2017] [Revised: 01/11/2018] [Accepted: 02/08/2018] [Indexed: 11/30/2022]
Abstract
Background Palliative repair of single ventricle defects involve a series of open-heart surgeries where a single-ventricle (Fontan) circulation is established. As the patient ages, this paradoxical circulation gradually fails, because of its high venous pressure levels. Reversal of the Fontan paradox requires an extra subpulmonic energy that can be provided through mechanical assist devices. The objective of this study was to evaluate the hemodynamic performance of a totally implantable integrated aortic-turbine venous-assist (iATVA) system, which does not need an external drive power and maintains low venous pressure chronically, for the Fontan circulation. Methods Blade designs of the co-rotating turbine and pump impellers were developed and 3 prototypes were manufactured. After verifying the single-ventricle physiology at a pulsatile in vitro circuit, the hemodynamic performance of the iATVA system was measured for pediatric and adult physiology, varying the aortic steal percentage and circuit configurations. The iATVA system was also tested at clinical off-design scenarios. Results The prototype iATVA devices operate at approximately 800 revolutions per minute and extract up to 10% systemic blood from the aorta to use this hydrodynamic energy to drive a blood turbine, which in turn drives a mixed-flow venous pump passively. By transferring part of the available energy from the single-ventricle outlet to the venous side, the iATVA system is able to generate up to approximately 5 mm Hg venous recovery while supplying the entire caval flow. Conclusions Our experiments show that a totally implantable iATVA system is feasible, which will eliminate the need for external power for Fontan mechanical venous assist and combat gradual postoperative venous remodeling and Fontan failure.
Collapse
|
44
|
Cavopulmonary mechanical circulatory support in Fontan patients and the need for physiologic control: A computational study with a closed-loop exercise model. Int J Artif Organs 2018. [DOI: 10.1177/0391398818762359] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Purpose: Rotary blood pumps are a promising treatment approach for patients with a total cavopulmonary connection and a failing cardiovascular system. The aim of this study was to investigate the hemodynamic effects of cavopulmonary support using a numerical model with closed-loop baroreflex and exercise mechanisms. Methods: A numerical model of the univentricular cardiovascular system was developed, mimicking the hemodynamics during rest and exercise. Rotary blood pumps with different hydraulic pump characteristics (flat vs steep pressure-flow relationships) were investigated in the cavopulmonary position. Furthermore, two support modes—a constant speed setting and a physiologically controlled speed—were examined. Results: Hemodynamics without rotary blood pumps were achieved with less than 10% deviation from reported values during rest and exercise. Rotary blood pumps at constant speed improve the hemodynamics at rest, however, they constitute a hydraulic resistance during light (steep characteristics) or moderate (flat characteristics) exercise. In contrast, physiologic control increases cardiac output (moderate exercise: 8.2 vs 7.4 L/min) and reduces sympathetic activation (heart rate at moderate exercise: 111 vs 123 bpm). Conclusion: In this simulation study, the necessity of an automatically controlled rotary blood pump in the cavopulmonary position was shown. A pump at constant speed might constitute an additional resistance to venous return during physical activity. Therefore, a physiologic control algorithm based on the pressure difference between the caval veins and the atrial pressure is proposed to improve hemodynamics, especially during physical activity.
Collapse
|
45
|
Extracorporeal Membrane Oxygenation (ECMO) Support in Special Patient Populations-The Bidirectional Glenn and Fontan Circulations. Front Pediatr 2018; 6:299. [PMID: 30386759 PMCID: PMC6199392 DOI: 10.3389/fped.2018.00299] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Accepted: 09/25/2018] [Indexed: 01/27/2023] Open
Abstract
Extracorporeal membrane oxygenation (ECMO) is a support modality used within the pediatric cardiac ICU population as a bridge to recovery or decision in the setting of acute myocardial decompensation, support for combined cardiopulmonary failure or in the setting of refractory cardiopulmonary arrest. Patients with univentricular physiology are at particular risk for decompensation requiring ECMO support. This review will focus upon current evidence and techniques for ECMO support of single ventricle patients who have undergone a stage II bidirectional Glenn procedure or the stage III Fontan procedure.
Collapse
|
46
|
Cardiovascular anatomy in children with bidirectional Glenn anastomosis, regarding the transcatheter Fontan completion. Arch Cardiovasc Dis 2017; 111:257-269. [PMID: 29146107 DOI: 10.1016/j.acvd.2017.08.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/27/2017] [Revised: 05/14/2017] [Accepted: 08/07/2017] [Indexed: 11/25/2022]
Abstract
BACKGROUND Transcatheter stent-secured completion of total cavopulmonary connection (TCPC) after surgical preparations during the Glenn anastomosis procedure has been reported, but complications from this approach have precluded its clinical acceptance. AIMS To analyse cardiovascular morphology and dimensions in children with bidirectional Glenn anastomosis, regarding the optimal device design for transcatheter Fontan completion without special surgical "preconditionings". METHODS We retrospectively analysed 60 thoracic computed tomography and magnetic resonance angiograms performed in patients with a median age of 4.1 years (range: 1.8-17.1 years). Additionally, we simulated TCPC completion using different intra-atrial stent-grafts in a three-dimensional model of the representative anatomy, and performed calculations to determine the optimal stent-graft dimensions, using measured distances. RESULTS Two types of cardiovascular arrangement were identified: left atrium interposing between the right pulmonary artery (RPA) and inferior vena cava, with the right upper pulmonary vein (RUPV) orifice close to the intercaval axis (65%); and intercaval axis traversing only the right(-sided) atrial cavity, with the RUPV located posterior to the atrial wall (35%). In the total population, the shortest median RPA-to-atrial wall distance was 1.9mm (range: 0.6-13.8mm), while the mean intra-atrial distance along the intercaval axis was 50.1±11.2mm. Regardless of the arrangement, 83% of all patients required a deviation of at least 5.9±2.4mm (range: 1.2-12.7mm) of the stent-graft centre at the RUPV level anteriorly to the intercaval axis to avoid covering or compressing this vein. Fixing the anterior deviation of the curved stent-graft centre at 10mm significantly decreased the range of bend angle per every given RUPV-RPA distance. CONCLUSIONS For both types of cardiovascular arrangement, after conventional bidirectional Glenn anastomosis, the intra-atrial curved stent-graft seemed most suitable for achieving uncomplicated TCPC completion percutaneously without previous surgical "preconditionings" in the majority of children. Experimental study is necessary to validate this conclusion.
Collapse
|
47
|
Mechanical Circulatory Support of the Fontan Patient. Semin Thorac Cardiovasc Surg Pediatr Card Surg Annu 2017; 20:20-27. [PMID: 28007060 DOI: 10.1053/j.pcsu.2016.09.009] [Citation(s) in RCA: 32] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2016] [Revised: 09/15/2016] [Accepted: 09/16/2016] [Indexed: 12/30/2022]
Abstract
Because of the inadequacies inherent to a circulation supported by a single ventricle, many Fontan patients will experience failure of their circulation. To date, there is no medical regimen that reliably and consistently restores circulatory function in these patients. Because of the shortage of donor organs and the fact that many of these patients present with features that either preclude or render heart transplantation a high risk, there is an intense need to better understand how mechanical circulatory support (MCS) may benefit these patients. In this report, we share our experience of successful MCS and transplantation of three patients. Our experience and that of others is very encouraging, but also preliminary. In general, a systemic ventricular assist device, with or without a Fontan fenestration, is a reasonable consideration for a patient presenting with predominantly systolic dysfunction. A pulmonary/systemic venous assist device may be sufficient for the patient with preserved systolic function and failure of the systemic venous/lymphatic system; however, this remains speculative. The more comprehensive approach of a total artificial heart or bilateral support is attractive in theory, but beset by the need for a more complex operation. In all scenarios, early referral, before organ failure, is paramount to successful MCS.
Collapse
|
48
|
|
49
|
Statistical Shape Modeling for Cavopulmonary Assist Device Development: Variability of Vascular Graft Geometry and Implications for Hemodynamics. J Med Device 2017; 11. [PMID: 28479938 DOI: 10.1115/1.4035865] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
Patients born with a single functional ventricle typically undergo three-staged surgical palliation in the first years of life, with the last stage realizing a cross-like total cavopulmonary connection (TCPC) of superior and inferior vena cavas (SVC and IVC) with both left and right pulmonary arteries, allowing all deoxygenated blood to flow passively back to the lungs (Fontan circulation). Even though within the past decades more patients survive into adulthood, the connection comes at the prize of deficiencies such as chronic systemic venous hypertension and low cardiac output, which ultimately may lead to Fontan failure. Many studies have suggested that the TCPC's inherent insufficiencies might be addressed by adding a cavopulmonary assist device (CPAD) to provide the necessary pressure boost. While many device concepts are being explored, few take into account the complex cardiac anatomy typically associated with TCPCs. In this study, we focus on the extra cardiac conduit vascular graft connecting IVC and pulmonary arteries as one possible landing zone for a CPAD and describe its geometric variability in a cohort of 18 patients that had their TCPC realized with a 20mm vascular graft. We report traditional morphometric parameters and apply statistical shape modeling to determine the main contributors of graft shape variability. Such information may prove useful when designing CPADs that are adapted to the challenging anatomical boundaries in Fontan patients. We further compute the anatomical mean 3D graft shape (template graft) as a representative of key shape features of our cohort and prove this template graft to be a significantly better approximation of population and individual patient's hemodynamics than a commonly used simplified tube geometry. We therefore conclude that statistical shape modeling results can provide better models of geometric and hemodynamic boundary conditions associated with complex cardiac anatomy, which in turn may impact on improved cardiac device development.
Collapse
|
50
|
Circulatory support using the impella device in fontan patients with systemic ventricular dysfunction: A multicenter experience. Catheter Cardiovasc Interv 2017; 90:118-123. [DOI: 10.1002/ccd.26885] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2016] [Revised: 10/12/2016] [Accepted: 11/20/2016] [Indexed: 11/12/2022]
|