1
|
Roditis K, Tsiantoula P, Giannakopoulos NN, Antoniou A, Papaioannou V, Tzamtzidou S, Manou D, Seretis KG, Papas TT, Bessias N. Laparoscopic Ligation of the Inferior Mesenteric Artery: A Systematic Review of an Emerging Trend for Addressing Type II Endoleak Following Endovascular Aortic Aneurysm Repair. J Clin Med 2024; 13:2584. [PMID: 38731113 PMCID: PMC11084248 DOI: 10.3390/jcm13092584] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2024] [Revised: 04/21/2024] [Accepted: 04/25/2024] [Indexed: 05/13/2024] Open
Abstract
Background/Objectives: this systematic review aims to explore the efficacy and safety of the laparoscopic ligation of the inferior mesenteric artery (IMA) as an emerging trend for addressing a type II endoleak following endovascular aortic aneurysm repair (EVAR). Methods: A comprehensive literature search was conducted across several databases including Medline, Scopus, and the Cochrane Central Register of Controlled Trials, adhering to the PRISMA guidelines. The search focused on articles reporting on the laparoscopic ligation of the IMA for the treatment of a type II endoleak post-EVAR. Data were extracted regarding study characteristics, patient demographics, technical success rates, postoperative outcomes, and follow-up results. Results: Our analysis included ten case studies and two retrospective cohort studies, comprising a total of 26 patients who underwent a laparoscopic ligation of the IMA between 2000 and 2023. The mean age of the cohort was 72.3 years, with a male predominance (92.3%). The mean AAA diameter at the time of intervention was 69.7 mm. The technique demonstrated a high technical success rate of 92.3%, with a mean procedure time of 118.4 min and minimal blood loss. The average follow-up duration was 19.9 months, with 73% of patients experiencing regression of the aneurysmal sac, and no reports of an IMA-related type II endoleak during the follow-up period. Conclusions: The laparoscopic ligation of the IMA for a type II endoleak following EVAR presents a promising, minimally invasive alternative with high technical success rates and favorable postoperative outcomes. Despite its potential advantages, including reduced contrast agent use and radiation exposure, its application remains limited to specialized centers. The findings suggest the need for further research in larger prospective studies to validate the effectiveness of this procedure and potentially broaden its clinical adoption.
Collapse
Affiliation(s)
- Konstantinos Roditis
- Department of Vascular Surgery, Korgialenio-Benakio Hellenic Red Cross Hospital, 115 26 Athens, Greece; (P.T.); (N.-N.G.); (A.A.); (V.P.); (S.T.); (D.M.); (K.G.S.); (T.T.P.); (N.B.)
| | | | | | | | | | | | | | | | | | | |
Collapse
|
2
|
Sultan S, Acharya Y, Hezima M, Chua Vi Long K, Soliman O, Parodi J, Hynes N. Two decades of experience in explantation and graft preserving strategies following primary endovascular aneurysm repair and lessons learned. Front Surg 2022; 9:963172. [PMID: 36570807 PMCID: PMC9774497 DOI: 10.3389/fsurg.2022.963172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2022] [Accepted: 07/26/2022] [Indexed: 12/13/2022] Open
Abstract
Objectives We aim to scrutinize our evolving re-intervention strategies following primary endovascular aortic aneurysm repair (EVAR) - EVAR GORE SalvAge Fabric Technique (ARAFAT), aortic sac double breasting with endograft preservation, and stent-graft explantation. Methods We performed 1,555 aortic interventions over the study period, including 910 EVARs. Factors associated with the need for reintervention and the likelihood of chronic fabric fatigue failure (CFFF) were investigated. Using conventional and innovative diagnostic modalities with Prone contrASt enHanced computed tomography Angiography (PASHA), 136 endoleaks (ELs) were identified (15 type I, 98 type II; 18 type III; 5 type IV). Results Forty-four (4.84%) patients underwent re-intervention post-primary EVAR; 18 ARAFATs, 12 double breastings, and 14 explantations. Choice of re-intervention was based on patient fitness and mode of failure. Mean EL detection duration following primary EVAR was 53.3 ± 6.82 months, while mean time to re-intervention was 70.20 ± 6.98 months. The mean sac size before the primary EVAR and re-intervention was 6.00 ± 1.75 cm and 7.51 ± 1.94 cm, respectively. Polyester (61.40%) was the most commonly employed stent-graft material. Use of more than three modular stent-graft components (3.42 ± 1.31, p = 0.846); with the proximal stent-graft diameter of 31.6 ± 3.80 cm (p = 0.651) and the use of iliac limbs more than 17 mm (p = 0.364), all added together are contributing factors. We had one peri-operative mortality following explantation due to sepsis-induced multiorgan failure. Conclusions Our re-intervention strategies matured from stent graft explantation to graft preservation with endovascular relining of the stent-graft. Graft preservation with aortic sacotomy and double breasting were used to manage concealed ELs due to aortic hygroma.
Collapse
Affiliation(s)
- Sherif Sultan
- Western Vascular Institute, Department of Vascular and Endovascular Surgery, University Hospital Galway, National University of Ireland, Galway, Ireland,Galway: Department of Vascular Surgery and Endovascular Surgery, Galway Clinic, Doughiska, Royal College of Surgeons in Ireland and National University of Ireland, Galway affiliated Hospital, Galway, Ireland,CORRIB-CURAM-Vascular Group, National University of Ireland, Galway, Ireland,Correspondence: Sherif Sultan ,
| | - Yogesh Acharya
- Western Vascular Institute, Department of Vascular and Endovascular Surgery, University Hospital Galway, National University of Ireland, Galway, Ireland,Galway: Department of Vascular Surgery and Endovascular Surgery, Galway Clinic, Doughiska, Royal College of Surgeons in Ireland and National University of Ireland, Galway affiliated Hospital, Galway, Ireland
| | - Mohieldin Hezima
- Western Vascular Institute, Department of Vascular and Endovascular Surgery, University Hospital Galway, National University of Ireland, Galway, Ireland
| | - Keegan Chua Vi Long
- Western Vascular Institute, Department of Vascular and Endovascular Surgery, University Hospital Galway, National University of Ireland, Galway, Ireland
| | - Osama Soliman
- CORRIB-CURAM-Vascular Group, National University of Ireland, Galway, Ireland
| | - Juan Parodi
- Department of Vascular Surgery and Biomedical Engineering Department, Alma mater, University of Buenos Aires, and Trinidad Hospital, Buenos Aires, Argentina,Winston-Salem and St. Louis: Wake Forest University, Winston-Salem, North Carolina and Washington University in St. Louis, St. Louis, Missouri, United States of America
| | - Niamh Hynes
- CORRIB-CURAM-Vascular Group, National University of Ireland, Galway, Ireland
| |
Collapse
|
3
|
San Norberto EM, Fidalgo-Domingos LA, Romero A, Vaquero C. Total Laparoscopic Inferior Mesenteric Artery Ligation and Direct Sac Puncture Embolization Technique for Treatment of Type II Endoleak. Vasc Endovascular Surg 2019; 54:278-282. [PMID: 31752622 DOI: 10.1177/1538574419885271] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Type II endoleak relates to aneurysm perfusion through a patent branch vessel. Reintervention for type II endoleak should be considered in the presence of significant aneurysm growth. Recurrences and subsequent reinterventions are frequent by occult type II endoleaks through feeder arterial branches. We report a case of a patient with a type II endoleak due to inferior mesenteric artery (IMA) patency associated with aneurysm sac growth after an unsuccessfully attempt of transarterial embolization. Laparoscopic ligation of the IMA with direct sac puncture embolization was performed. The postoperative and 1-year follow-up computed tomography angiography scan demonstrated no endoleak signs and aneurysm sac shrinkage. The proposed modification of this technique constitutes a novel approach to this entity. Total laparoscopic IMA ligation and direct sac puncture embolization technique may increase the success rate for the treatment of endoleaks type II by excluding the recurrences. This technique may offer a safe, feasible, and minimally invasive approach for type II endoleaks when other endovascular techniques are unsuccessful.
Collapse
Affiliation(s)
| | | | - Alejandro Romero
- Division of General Surgery, Valladolid University Hospital, Valladolid, Spain
| | - Carlos Vaquero
- Division of Vascular Surgery, Valladolid University Hospital, Valladolid, Spain
| |
Collapse
|
4
|
Morelli L, Guadagni S, Di Franco G, Palmeri M, Furbetta N, Gianardi D, Bianchini M, Moglia A, Di Candio G, Ferrari M, Berchiolli R. Technical details and preliminary results of a full robotic type II endoleak treatment with the da Vinci Xi. J Robot Surg 2019; 13:505-509. [PMID: 30830571 DOI: 10.1007/s11701-019-00944-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/24/2019] [Accepted: 02/25/2019] [Indexed: 02/05/2023]
Abstract
Type II endoleak (T2E) represents a frequent and often challenging complication of endovascular aneurysm repair (EVAR). Endovascular treatment is the standard and most used strategy, but the recurrence after it remains high, especially due to lumbar arteries (LA) and inferior mesenteric artery (IMA) feeding. While conventional laparoscopy has been considered as an emerging method, robotic surgery is not reported yet for this indication. We herein describe our technique of minimally invasive T2E repair using a full robotic approach with the da Vinci Xi, reporting our preliminary experience with the first two patients who underwent this operation at our Institution. The procedure comprises two phases. The first phase consists of IMA ligation, left colon mobilization and infra-renal exposure of the anterior longitudinal ligament of the column and of the left side of the sac. The second phase entails the posterior aneurysm mobilization and the selective clipping of LA responsible of the T2E, as identified by the pre-operative CT scan. No intra-operative complications occurred and the average length of surgery was 183 min. The average length of hospitalization was 2.5 days. Robotic T2E repair can be considered a safe procedure and the da Vinci Xi, thanks to its increased dexterity and flexibility, allows to easily perform this multi-target operation (IMA and LA). The articulated instruments with motion scaling and tremor filtering facilitate a gently vascular dissection and an easy IMA and LA identification, dissection, and ligation. The TilePro function permits the operator to control from the console, with intra-operative color-Doppler ultrasound, the absence of residual endoleaks.
Collapse
Affiliation(s)
- Luca Morelli
- General Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via Paradisa 2, Pisa, 56124, Italy.
- EndoCAS (Center for Computer Assisted Surgery), University of Pisa, Pisa, Italy.
| | - Simone Guadagni
- General Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via Paradisa 2, Pisa, 56124, Italy
| | - Gregorio Di Franco
- General Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via Paradisa 2, Pisa, 56124, Italy
| | - Matteo Palmeri
- General Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via Paradisa 2, Pisa, 56124, Italy
| | - Niccolò Furbetta
- General Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via Paradisa 2, Pisa, 56124, Italy
| | - Desirée Gianardi
- General Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via Paradisa 2, Pisa, 56124, Italy
| | - Matteo Bianchini
- General Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via Paradisa 2, Pisa, 56124, Italy
| | - Andrea Moglia
- EndoCAS (Center for Computer Assisted Surgery), University of Pisa, Pisa, Italy
| | - Giulio Di Candio
- General Surgery Unit, Department of Translational Research and New Technologies in Medicine and Surgery, University of Pisa, Via Paradisa 2, Pisa, 56124, Italy
| | - Mauro Ferrari
- EndoCAS (Center for Computer Assisted Surgery), University of Pisa, Pisa, Italy
- Vascular Surgery Unit, Department of CardioVascular Surgery, University of Pisa, Pisa, Italy
| | - Raffaella Berchiolli
- EndoCAS (Center for Computer Assisted Surgery), University of Pisa, Pisa, Italy
- Vascular Surgery Unit, Department of CardioVascular Surgery, University of Pisa, Pisa, Italy
| |
Collapse
|
5
|
Wee I, Marjot T, Patel K, Bhrugubanda V, Choong AMTL. Laparoscopic ligation of Type II endoleaks following endovascular aneurysm repair: A systematic review. Vascular 2018; 26:657-669. [PMID: 29966486 DOI: 10.1177/1708538118773611] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
INTRODUCTION The clinical significance of Type II endoleak remains contentious; the strategies used for its management have continued to expand. We systematically review the literature and comprehensively appraise the effectiveness of laparoscopic intervention in the management of this common complication. METHODS A systematic search was performed in accordance to the Preferred Reporting Items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines on MEDLINE, EMBASE and Cochrane Library for relevant articles reporting laparoscopic surgery of Type II endoleak post-endovascular aortic repair. RESULTS Thirteen studies representing 40 patients were investigated. Mean age was 72.7 years, and proportion of males was 90.0%. All patients were American Society of Anesthesiologists grade II and above and underwent standard infrarenal endovascular aneurysm repair. The mean duration of operation was 130.2 min, with a mean blood loss across of 173.8 mL. The overall technical success rate was 90% (27/30). Two patients required reoperation within 24 h, with further lumbar ligations that were successful. One other patient required conversion to open surgery due to significant bleeding at the dorsal aorta. The perioperative and 30-day mortality rate was 2.5% (1/40). The mean length of hospital stay was 3.7 days (range 1 to 10 days). The mean length of follow-up was 36.7 months (range 3 to 103.2 months), where the rate of recurrence was 22.5% (9/40). CONCLUSIONS Laparoscopic ligation of feeding vessels causing Type II endoleak is potentially an alternative treatment after failed standard endovascular embolization, particularly in select centres with necessary resources and capabilities.
Collapse
Affiliation(s)
- Ian Wee
- 1 SingVaSC, Singapore Vascular Surgical Collaborative, Singapore, Singapore
- 2 Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| | - Thomas Marjot
- 1 SingVaSC, Singapore Vascular Surgical Collaborative, Singapore, Singapore
- 3 Imperial College Healthcare NHS Trust, London, UK
| | - Kirtan Patel
- 1 SingVaSC, Singapore Vascular Surgical Collaborative, Singapore, Singapore
- 4 Southend University Hospital National Health Service Foundation Trust, Essex, UK
| | - Vamsee Bhrugubanda
- 1 SingVaSC, Singapore Vascular Surgical Collaborative, Singapore, Singapore
- 5 Lancashire Teaching Hospitals Trust National Health Service Foundation Trust, Preston, UK
| | - Andrew MTL Choong
- 1 SingVaSC, Singapore Vascular Surgical Collaborative, Singapore, Singapore
- 6 Cardiovascular Research Institute, National University of Singapore, Singapore, Singapore
- 7 Division of Vascular Surgery, National University Heart Centre, Singapore, Singapore
- 8 Department of Surgery, Yong Loo Lin School of Medicine, National University of Singapore, Singapore, Singapore
| |
Collapse
|
6
|
Rahimi S, Nassiri N, Huntress L, Crystal D, Thomas J, Shafritz R. An Institution-Wide Algorithm for Treatment of Type II Endoleak Following Endovascular Aneurysm Repair (EVAR). Vasc Endovascular Surg 2018; 52:249-254. [DOI: 10.1177/1538574418761269] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Objectives: Multiple endovascular techniques have been described for the treatment of persistent type II endoleaks (pT2ELs) causing aneurysm sac growth following endovascular aneurysm repair (EVAR). In the event of a failed endovascular procedure and a pT2EL, a consensus regarding further treatment is lacking, and the literature suggests repeated endovascular attempts are rarely successful. Herein, we propose an algorithm for definitive management of pT2ELs with persistent sac growth following EVAR. Methods: A retrospective review of 29 patients who underwent treatment of persistent sac growth in the setting of pT2ELs was performed. Intervention methods were determined at the discretion of the operating surgeon. Aneurysmal sac enlargement was defined as a diameter increase > 5 mm, and persistent endoleak was defined as lasting greater than 6 months. Results: From 2000 to 2015, 917 EVAR procedures were performed at our institution. Isolated pT2ELs with sac enlargement were identified in 29 patients. Twenty-five patients underwent direct translumbar sac puncture and coiling and/or Onyx (Onyx, Plymouth, Minnesota) embolization of the culprit vessels. Thirteen (52%) of 25 patients had pT2EL after first endovascular intervention, and 10 (40%) of 25 patients failed 2 endovascular treatments. Of those 10, 7 displayed persistent aneurysmal sac growth and underwent a third embolization procedure. Type II endoleaks persisted in 6 patients; 3 patients were subsequently treated with laparotomy, ligation of lumbar vessels, sac exploration, and sac plication around the endograft. Technical success for this technique was 100%. During a mean follow-up of 38.4 months, no recurrent T2ELs, stent graft migration, and/or disjunction were observed. Conclusions: We propose a new algorithm for the management of pT2ELs. If 2 endovascular procedures fail to control of the endoleak, repeat endovascular attempts are not recommended. Endovascular failure should be followed by laparotomy with surgical ligation of culprit feeding vessels followed by sac exploration and plication of the sac, and endoaneurysmorrhaphy.
Collapse
Affiliation(s)
- Saum Rahimi
- Division of Vascular Surgery, Department of Surgery, Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, USA
| | - Naiem Nassiri
- Division of Vascular Surgery, Department of Surgery, Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, USA
| | - Lauren Huntress
- Rutgers-Robert Wood Johnson Medical School, New Brunswick, NJ, USA
| | - Dustin Crystal
- Rutgers-Robert Wood Johnson Medical School, New Brunswick, NJ, USA
| | - Jones Thomas
- Rutgers-Robert Wood Johnson Medical School, New Brunswick, NJ, USA
| | - Randy Shafritz
- Division of Vascular Surgery, Department of Surgery, Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, USA
| |
Collapse
|
7
|
Zubair MM, Chinnadurai P, Loh FE, Loh TM, Lumsden AB, Bechara CF. A novel technique combining laparoscopic and endovascular approaches using image fusion guidance for anterior embolization of type II endoleak. J Vasc Surg Cases Innov Tech 2017; 3:7-10. [PMID: 29349363 PMCID: PMC5757813 DOI: 10.1016/j.jvscit.2016.09.005] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2016] [Accepted: 09/15/2016] [Indexed: 11/20/2022] Open
Abstract
Type II endoleak (T2E) leading to aneurysm sac enlargement is one of the challenging complications associated with endovascular aneurysm repair. Recent guidelines recommend embolization of T2E associated with aneurysmal sac enlargement. Various percutaneous and endovascular techniques have been reported for embolization of T2E. We report a novel technique for T2E embolization combining laparoscopic and endovascular approaches using preoperative image fusion. We believe our technique provides a more direct access to the lumbar feeding vessels that is typically challenging with transarterial or translumbar embolization techniques.
Collapse
Affiliation(s)
- M. Mujeeb Zubair
- Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Tex
| | - Ponraj Chinnadurai
- Angiography Division, Siemens Medical Solutions USA Inc, Hoffman Estates, Ill
| | - Francis E. Loh
- Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Tex
| | - Thomas M. Loh
- Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Tex
| | - Alan B. Lumsden
- Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Tex
| | - Carlos F. Bechara
- Methodist DeBakey Heart & Vascular Center, Houston Methodist Hospital, Houston, Tex
| |
Collapse
|
8
|
Barleben A, Inui T, Owens E, Lane JS, Bandyk DF. Intervention after endovascular aneurysm repair: Endosalvage techniques including perigraft arterial sac embolization and endograft relining. Semin Vasc Surg 2016; 29:41-49. [PMID: 27823589 DOI: 10.1053/j.semvascsurg.2016.06.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Endovascular aneurysm repair (EVAR) has revolutionized the treatment of abdominal aortic aneurysm (AAA). However, persistent AAA sac endoleak following EVAR can result in sac diameter increase requiring re-intervention in up to one-third of cases and even result in aneurysm rupture. In this case review, we summarize and detail endovascular re-interventions for each type of endoleak. We also detail specific options including stent-graft relining for indeterminate, Type III, and Type IV endoleaks and perigraft arterial sac embolization to induce thrombosis and resolve acute Type I, II, or III endoleaks. Endograft relining involves placement of a new stent-graft-elevating the bifurcation and extending the repair from renal artery to hypogastric arteries; perigraft arterial sac embolization involves placement of a catheter into the excluded sac from common femoral artery access, characterization of the inflow and outflow of the endoleak, and inducing cessation of the blood flow into the sac by the administration of thrombogenic material. Endoleaks range from low-pressure endoleaks, which can be safely monitored in a surveillance program to high-pressure endoleaks, which mandate intervention when associated with AAA sac diameter increase to protect from rupture. The evaluation of new devices and techniques to treat endoleak after EVAR remains an important issue in patient care after EVAR.
Collapse
Affiliation(s)
- Andrew Barleben
- Division of Vascular and Endovascular Surgery, Sulpizio Cardiovascular Center, University of California-San Diego School of Medicine, 9434 Medical Center Drive, Mail Code 7403, La Jolla, CA 92037; Department of Surgery, Division of Vascular Surgery, San Diego Veteran's Administration, La Jolla, CA.
| | - Tazo Inui
- Division of Vascular and Endovascular Surgery, Sulpizio Cardiovascular Center, University of California-San Diego School of Medicine, 9434 Medical Center Drive, Mail Code 7403, La Jolla, CA 92037; Department of Surgery, Division of Vascular Surgery, San Diego Veteran's Administration, La Jolla, CA
| | - Erik Owens
- Department of Surgery, Division of Vascular Surgery, San Diego Veteran's Administration, La Jolla, CA
| | - John S Lane
- Division of Vascular and Endovascular Surgery, Sulpizio Cardiovascular Center, University of California-San Diego School of Medicine, 9434 Medical Center Drive, Mail Code 7403, La Jolla, CA 92037; Department of Surgery, Division of Vascular Surgery, San Diego Veteran's Administration, La Jolla, CA
| | - Dennis F Bandyk
- Division of Vascular and Endovascular Surgery, Sulpizio Cardiovascular Center, University of California-San Diego School of Medicine, 9434 Medical Center Drive, Mail Code 7403, La Jolla, CA 92037; Department of Surgery, Division of Vascular Surgery, San Diego Veteran's Administration, La Jolla, CA
| |
Collapse
|
9
|
Maitrias P, Kaladji A, Plissonnier D, Amiot S, Sabatier J, Coggia M, Magne JL, Reix T. Treatment of sac expansion after endovascular aneurysm repair with obliterating endoaneurysmorrhaphy and stent graft preservation. J Vasc Surg 2016; 63:902-8. [DOI: 10.1016/j.jvs.2015.10.059] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Accepted: 10/13/2015] [Indexed: 01/10/2023]
|
10
|
Brown A, Saggu GK, Bown MJ, Sayers RD, Sidloff DA. Type II endoleaks: challenges and solutions. Vasc Health Risk Manag 2016; 12:53-63. [PMID: 27042087 PMCID: PMC4780400 DOI: 10.2147/vhrm.s81275] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023] Open
Abstract
Type II endoleaks are the most common endovascular complications of endovascular abdominal aortic aneurysm repair (EVAR); however, there has been a divided opinion regarding their significance in EVAR. Some advocate a conservative approach unless there is clear evidence of sac expansion, while others maintain early intervention is best to prevent adverse late outcomes such as rupture. There is a lack of level-one evidence in this challenging group of patients, and due to a low event rate of complications, large numbers of patients would be required in well-designed trials to fully understand the natural history of type II endoleak. This review will discuss the imaging, management, and outcome of patients with isolated type II endoleaks following infra-renal EVAR.
Collapse
Affiliation(s)
- Andrew Brown
- Department of Vascular Surgery, Queens Medical Centre, University of Nottingham, Nottingham, UK
| | - Greta K Saggu
- Department of Vascular Surgery, Queens Medical Centre, University of Nottingham, Nottingham, UK
| | - Matthew J Bown
- Department of Cardiovascular Sciences, National Institute for Health Research Leicester Cardiovascular Biomedical Research Unit, University of Leicester, Leicester, UK
| | - Robert D Sayers
- Department of Cardiovascular Sciences, National Institute for Health Research Leicester Cardiovascular Biomedical Research Unit, University of Leicester, Leicester, UK
| | - David A Sidloff
- Department of Vascular Surgery, Queens Medical Centre, University of Nottingham, Nottingham, UK; Department of Cardiovascular Sciences, National Institute for Health Research Leicester Cardiovascular Biomedical Research Unit, University of Leicester, Leicester, UK
| |
Collapse
|
11
|
Obliterative Endoaneurysmorrhaphy with Stent Graft Preservation for Treatment of Type II Progressive Endoleak. Eur J Vasc Endovasc Surg 2016; 51:38-42. [DOI: 10.1016/j.ejvs.2015.07.013] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Accepted: 07/08/2015] [Indexed: 11/18/2022]
|