1
|
Torrealba JI, Kölbel T. Reply. J Vasc Surg 2025; 81:1533. [PMID: 40414654 DOI: 10.1016/j.jvs.2025.02.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2025] [Revised: 02/06/2025] [Accepted: 02/07/2025] [Indexed: 05/27/2025]
Affiliation(s)
- Jose I Torrealba
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart and Vascular Center UKE Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Tilo Kölbel
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart and Vascular Center UKE Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
2
|
Simonte G, Fino G, Isernia G, Gatta E, Neri E, de Donato G, Parlani G, Vento V, Ricci C. Performance Analysis of a New Generation Balloon Expandable Covered Stent When used as Bridging Stent-Graft During Inner-Branched Complex Aortic Repair. Cardiovasc Intervent Radiol 2025:10.1007/s00270-025-04038-2. [PMID: 40325277 DOI: 10.1007/s00270-025-04038-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/13/2024] [Accepted: 03/30/2025] [Indexed: 05/07/2025]
Abstract
INTRODUCTION Target visceral vessels (TVVs) management during complex aortic treatments remains a critical aspect in endoluminal procedures. Bridge stent-graft (BSG) stability is essential for ensuring the effectiveness and safety of these interventions. Aim of this study was to assess the performance of the Viabahn balloon expandable (VBX) when used as BSG in association with Artivion's inner-branched endografts. METHODS All patients consecutively treated for complex aortic pathology with Artivion inner-branched devices were prospectively enrolled, and those receiving at least one VBX as BSG were included. Primary outcome included VBX-related technical success, reinterventions and freedom from target vessel instability. Cox-regression analysis was used to identify variables independently associated with TVVs instability. RESULTS Fifty-four patients were included in the study cohort. The total number of target visceral arteries bridged with a VBX through an inner branch was 159. VBX-related technical success was 99.4% (158/159). Each stent-graft was successfully delivered and deployed as planned without any intraprocedural endoleak. The VBX-related patency rate was 98% at 30 days (156/159). Three TVVs occlusions were recorded at follow-up, all asymptomatic and not requiring revascularization. A further TVV-related instability event was documented at a four-month follow-up. The mean follow-up was 11.4 ± 9.3 months. Estimates of freedom from TVVs occlusions and instability at 30 months were 96.6 and 96.0%, respectively. Cox-regression found no variables significantly associated with TVVs instability. CONCLUSION The VBX stent-graft appears to be a safe and effective bridging option for inner-branched thoracoabdominal aortic repair. Although preliminary results are promising, larger studies with longer follow-up are needed to validate these findings.
Collapse
Affiliation(s)
- Gioele Simonte
- Unit of Vascular and Endovascular Surgery, Santa Maria Della Misericordia Hospital, Piazzale Menghini, 1, 06129, Perugia, Italy.
| | - Gianluigi Fino
- Unit of Vascular and Endovascular Surgery, Santa Maria Della Misericordia Hospital, Piazzale Menghini, 1, 06129, Perugia, Italy
| | - Giacomo Isernia
- Unit of Vascular and Endovascular Surgery, Santa Maria Della Misericordia Hospital, Piazzale Menghini, 1, 06129, Perugia, Italy
| | - Emanuele Gatta
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti Di Ancona, Via Conca 71, 60126, Ancona, Italy
| | - Eugenio Neri
- Cardiac and Great Vessels Surgery Unit, University of Siena, V.le Mario Bracci 11, 53100, Siena, Italy
| | - Gianmarco de Donato
- Vascular Surgery Unit, Department of Medicine, Surgery and Neuroscience, University of Siena, V.le Mario Bracci 11, 53100, Siena, Italy
| | - Gianbattista Parlani
- Unit of Vascular and Endovascular Surgery, Santa Maria Della Misericordia Hospital, Piazzale Menghini, 1, 06129, Perugia, Italy
| | - Vincenzo Vento
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti Di Ancona, Via Conca 71, 60126, Ancona, Italy
| | - Carmelo Ricci
- Vascular and Interventional Radiology Unit, Azienda Ospedaliera Universitaria Senese, V.le Mario Bracci 11, 53100, Siena, Italy
| |
Collapse
|
3
|
Karelis A, Kölbel T, Mastracci T, Katsargyris A, Haulon S, Tsilimparis N, Antoniou GA. Branched Endovascular Aneurysm Repair with Inner and Outer Branches: A Systematic Review and Meta-analysis. Eur J Vasc Endovasc Surg 2025:S1078-5884(25)00231-X. [PMID: 40064233 DOI: 10.1016/j.ejvs.2025.03.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2024] [Revised: 02/18/2025] [Accepted: 03/05/2025] [Indexed: 05/09/2025]
Abstract
OBJECTIVE This systematic review aimed to assess the clinical outcomes of branched endovascular aneurysm repair (BEVAR) with inner branches (iBEVAR) and inner/outer branches (oBEVAR). DATA SOURCES A systematic literature review was performed using the electronic bibliographic databases MEDLINE, Embase, Scopus, Web of Science, and the Cochrane Library up to May 2024. REVIEW METHODS The review was designed and reported in accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses (PRISMA) guidelines. Eligible studies reported death, technical failure, primary target vessel (TV) patency, TV related complications, branch related re-interventions, and spinal cord ischaemia (SCI). Risk of bias was evaluated with the ROBINS-I tool. RESULTS Twenty seven observational studies reporting a total of 1 780 patients treated with BEVAR and 6 633 TVs were included. Three hundred and eightysix patients (84.3%) were treated electively with iBEVAR and 72 (15.6%) urgently vs. 845 (63.2%) and 491 (36.7%) with oBEVAR, respectively. The pooled estimate of 30 day death was 4.9% (95% confidence interval [CI] 2.9 - 8.2%) for iBEVAR and 7.6% (95% CI 4.9 - 11.7%) for oBEVAR. Overall mortality rates were 13.8% (95% CI 9.7 - 19.1%) for iBEVAR vs. 15.4% (95% CI 10.6 - 21.9%) for oBEVAR. The rate of SCI was 6.5% (95% CI 4.2 - 10.0%) in iBEVAR compared with 12.9% (95% CI 9.6 - 17.1%) in oBEVAR. Primary TV patency was similar between iBEVAR (97.3%, 95% CI 94.8 - 98.6%) and oBEVAR (97.6%, 95% CI 95.3 - 98.7%). TV related complication rates were 2.9% (95% CI 2.0 - 4.1%) for iBEVAR vs. 3.9% (95% CI 2.7 - 5.6%) for oBEVAR. Technical failure rates were 4.1% (95% CI 2.4 - 6.9%) for iBEVAR vs. 5.7% (95% CI 3.5 - 9.1%) for oBEVAR. Grading of Recommendations Assessment, Development, and Evaluation (GRADE) certainty was low or very low for all outcomes. CONCLUSION BEVAR with inner and inner/outer branches has been used in elective and urgent cases, as well as across a variety of anatomies, with both designs demonstrating satisfactory clinical outcomes.
Collapse
Affiliation(s)
- Angelos Karelis
- Vascular Centre, Department of Thoracic Surgery and Vascular Diseases, Skåne University Hospital, Malmö, Sweden; Department of Clinical Sciences Malmö, Lund University, Malmö, Sweden.
| | - Tilo Kölbel
- German Aortic Centre, University Heart and Vascular Centre, University Medical Centre Eppendorf, Hamburg, Germany
| | - Tara Mastracci
- University College London, St Bartholomew's Hospital, London, UK
| | - Athanasios Katsargyris
- Department of Vascular and Endovascular Surgery, Paracelsus Medical University Nuremberg, General Hospital Nuremberg, Nuremberg, Germany
| | | | - Nikolaos Tsilimparis
- Department of Vascular Surgery, University Hospital, LMU Munich, Munich, Germany
| | - George A Antoniou
- Department of Vascular and Endovascular Surgery, Manchester University NHS Foundation Trust, Manchester, UK; Division of Cardiovascular Sciences, School of Medical Sciences, Manchester Academic Health Science Centre, The University of Manchester, Manchester, UK
| |
Collapse
|
4
|
Gallitto E, Simonte G, Fointain V, Kahlberg A, Isernia G, Melissano G, Cecere F, Parlani G, Haulon S, Gargiulo M. Low Profile Off the Shelf Multibranched Endografts for Urgent Endovascular Repair of Complex Aortic and Thoraco-abdominal Aneurysms in Patients with Hostile Iliac Access: European Multicentre Observational Study. Eur J Vasc Endovasc Surg 2025; 69:371-379. [PMID: 39571885 DOI: 10.1016/j.ejvs.2024.10.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2024] [Revised: 09/12/2024] [Accepted: 10/18/2024] [Indexed: 12/22/2024]
Abstract
OBJECTIVE The aim of the study was to report outcomes of a thoraco-abdominal, custom made, low profile (outer diameter 20 F) four branched endograft used as an off the shelf (OTS) solution for urgent juxta- and pararenal abdominal aortic aneurysms (JP-AAAs) and thoraco-abdominal aortic aneurysms (TAAAs) in the presence of hostile femoral or iliac access. METHODS Data for patients who underwent endovascular repair for urgent JP-AAAs and TAAAs with hostile femoral or iliac access by a low profile, four branched endograft in four European aortic centres between 2019 and 2023 were collected prospectively and analysed retrospectively. The investigated device was a custom made endograft with the configuration of a standard t-Branch, used as an OTS solution for urgent cases with hostile femoral or iliac access. Access related complications, spinal cord ischaemia (SCI), and 30 day death were assessed as primary outcomes. Survival, freedom from re-interventions (FFRs), and iliac limb occlusion (ILO) were evaluated as secondary outcomes. RESULTS Fifty five cases were enrolled: ruptures, n = 14 (25%); symptomatic, n = 12 (22%); and asymptomatic TAAAs with diameter ≥ 80 mm, n = 29 (53%). There were seven (13%) JP-AAAs and 48 (87%) TAAAs. The median right and left external iliac artery diameters were 6.7 (interquartile range [IQR] 5.5, 7.9) mm and 7.1 (IQR 6.5, 8.7) mm, respectively. Bilateral hostile femoral or iliac access was reported in 39 patients (71%). Access related complications occurred in five cases (9%). There were four cases (7%) of SCI with two permanent paraplegias. Four patients (7%) died within 30 days. The median follow up was 22 (IQR 11, 33) months. Overall, eight patients (15%) required re-interventions: four within 30 days and four during follow up. No ILO occurred. Estimated one year FFRs and survival were 91% and 87%, respectively. CONCLUSION Low profile OTS thoraco-abdominal endografts seems safe and effective to manage urgent JP-AAAs and TAAAs in the presence of hostile femoral or iliac access. Further larger studies with long term follow up are needed to validate this preliminary experience.
Collapse
Affiliation(s)
- Enrico Gallitto
- Vascular Surgery, University of Bologna - DIMEC, Bologna, Italy; Vascular Surgery Unit, IRCCS, University Hospital Policlinico S. Orsola, Bologna, Italy.
| | - Gioele Simonte
- Vascular and Endovascular Surgery Unit, Hospital S. Maria Misericordia, University of Perugia, Perugia, Italy
| | | | - Andrea Kahlberg
- Division of Vascular Surgery, Vita - Salute University, Scientific Institute H. San Raffaele, Milan, Italy
| | - Giacomo Isernia
- Vascular and Endovascular Surgery Unit, Hospital S. Maria Misericordia, University of Perugia, Perugia, Italy
| | - Germano Melissano
- Vascular and Endovascular Surgery Unit, Hospital S. Maria Misericordia, University of Perugia, Perugia, Italy
| | - Fabrizio Cecere
- Vascular Surgery, University of Bologna - DIMEC, Bologna, Italy
| | - Gianbattista Parlani
- Vascular and Endovascular Surgery Unit, Hospital S. Maria Misericordia, University of Perugia, Perugia, Italy
| | - Stephan Haulon
- Vascular Surgery, Hospital Marie Lannelongue, Paris, France
| | - Mauro Gargiulo
- Vascular Surgery, University of Bologna - DIMEC, Bologna, Italy; Vascular Surgery Unit, IRCCS, University Hospital Policlinico S. Orsola, Bologna, Italy
| |
Collapse
|
5
|
Calo P, Yordanov M, Frederik SJ, Oberhuber A. The E-nside, multi-inner branch-based off-the-shelf stent graft for the treatment of thoracoabdominal aortic aneurysms. Expert Rev Med Devices 2025; 22:177-185. [PMID: 39953691 DOI: 10.1080/17434440.2025.2465686] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 12/16/2024] [Accepted: 01/08/2025] [Indexed: 02/17/2025]
Abstract
INTRODUCTION Endovascular repair for thoracoabdominal aortic aneurysms (TAAAs) has changed treatment paradigm over the past decades. However for urgent cases, there are not many options available. The E-nside (Artivion, Georgia, U.S.A.) endograft is one of the three off-the-shelf-aortic endografts available on the market. Its unique design with four inner branches and other special features offer more versatility, so more patients could be minimally invasively treated. AREAS COVERED We present a descriptive review based on market analysis on the available devices and a PubMed literature research on the E-nside endograft. The aim of this article is to present its unique structure, deployment method, and cannulation methods and discuss its applicability, indications, associated concerns and an overview of the available alternative devices. EXPERT OPINION The implantation of the E-nside endograft is a promising technique for treating not only TAAAs but also complex abdominal aortic aneurysm. Unlike FEVAR or BEVAR, which require precise planning and have the disadvantage of long manufacturing time. We think that with the off-the-shelf feature from E-nside endograft this can be obviated, and through its flexible planning along with its simple use, more patients could benefit and so favorable results can be achieve.
Collapse
Affiliation(s)
- Paolo Calo
- Department of Vascular and Endovascular Surgery, University Hospital of Muenster, Münster, Germany
| | - Miroslav Yordanov
- Department of Vascular and Endovascular Surgery, University Hospital of Muenster, Münster, Germany
| | | | - Alexander Oberhuber
- Department of Vascular and Endovascular Surgery, University Hospital of Muenster, Münster, Germany
| |
Collapse
|
6
|
Torrealba JI, Panuccio G, Nana P, Giordano A, Al Sarhan DY, Kölbel T. Midterm single-center results with the use of custom-made endografts with inner branches, a call for attention. J Vasc Surg 2025; 81:310-317. [PMID: 39427719 DOI: 10.1016/j.jvs.2024.09.039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2024] [Revised: 08/30/2024] [Accepted: 09/08/2024] [Indexed: 10/22/2024]
Abstract
OBJECTIVE The aim of this study was to evaluate the patency of bridging covered stents (BCS) bridged to inner branches in custom-made thoracoabdominal endografts. METHODS This was a single-center retrospective study identifying all patients undergoing fenestrated or branched endovascular aortic repair (f/b EVAR) in whom the reno-visceral target vessels (TVs) were bridged with a BCS to an inner branch of a custom-made (CMD) endograft. Technical success and perioperative complications were noted. Follow-up BCS patencies were evaluated, and in patients with follow-up, two groups based on BCS were created, a group with BCS occlusion and a group with BCS patent. Univariable and multivariable analyses were performed to analyze factors related to visceral and renal bridging stent occlusion. RESULTS From 2019 through 2022, 69 patients undergoing complex aortic repair had at least one TV bridged to an inner branch built into a CMD endograft. Eighty-six percent of the grafts had only inner branches, whereas 14% had a mix of fenestrations for the visceral TVs and inner branches for the renal arteries. Twenty-five percent of patients presented as urgent and received an endograft originally designed for another patient and available on our shelf at the time. A total of 245 TVs were connected to inner branches: celiac trunk (CT), 54; superior mesenteric artery (SMA), 59; and renal artery (RA), 132. Technical success was 99%. There was a 23% complication and 9% perioperative mortality rate. At follow-up, we identified 6% of visceral and 14% of renal BCS occlusions. The primary patency for RA BCS was 83% at 12 months and 58% at 24 months. For the CT-SMA BCS, Kaplan-Maier showed a patency of 99% and 96% at 12 and 24 months. In the univariate analysis, a misaligned TV ostium (P = .001), the postoperative BCS diameter on postoperative computed tomography angiography (P = .02), and the preoperative infrarenal aortic angle >60° (P = .007) were correlated with RA BCS occlusion. In the multivariate analysis, only the misaligned TV ostium (P = .002) and infrarenal angle >60° (P = .01) were significantly correlated. CONCLUSIONS In our series of complex aortic repair, the incorporation of inner branches to bridge TVs is associated with a high renal BCS occlusion rate. Improper alignment of the branches with the TV ostium and acute aortic angles might play a significant role. Further research on this technology is needed.
Collapse
Affiliation(s)
- Jose I Torrealba
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart and Vascular Center UKE Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany.
| | - Giuseppe Panuccio
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart and Vascular Center UKE Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Petroula Nana
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart and Vascular Center UKE Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Antonino Giordano
- Department of Vascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy
| | - Daour Yousef Al Sarhan
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart and Vascular Center UKE Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Tilo Kölbel
- Department of Vascular Medicine, German Aortic Center Hamburg, University Heart and Vascular Center UKE Hamburg, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
7
|
Mazzolai L, Teixido-Tura G, Lanzi S, Boc V, Bossone E, Brodmann M, Bura-Rivière A, De Backer J, Deglise S, Della Corte A, Heiss C, Kałużna-Oleksy M, Kurpas D, McEniery CM, Mirault T, Pasquet AA, Pitcher A, Schaubroeck HAI, Schlager O, Sirnes PA, Sprynger MG, Stabile E, Steinbach F, Thielmann M, van Kimmenade RRJ, Venermo M, Rodriguez-Palomares JF. 2024 ESC Guidelines for the management of peripheral arterial and aortic diseases. Eur Heart J 2024; 45:3538-3700. [PMID: 39210722 DOI: 10.1093/eurheartj/ehae179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 09/04/2024] Open
|
8
|
Simonte G, Gatta E, Vento V, Parlani G, Simonte R, Montecchiani L, Isernia G. Partial Deployment to Save Space for Vessel Cannulation When Treating Complex Aortic Aneurysms with Narrow Paravisceral Lumen Is Also Feasible Using Inner-Branched Pre-Cannulated Endografts. J Clin Med 2024; 13:3060. [PMID: 38892771 PMCID: PMC11172520 DOI: 10.3390/jcm13113060] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2024] [Revised: 05/21/2024] [Accepted: 05/22/2024] [Indexed: 06/21/2024] Open
Abstract
Introduction: The aim of this paper is to propose a sequential deployment technique for the E-nside off-the-shelf endograft that could potentially enhance target visceral vessel (TVV) cannulation and overstenting in narrow aortic anatomies. Methods: All data regarding patients consecutively treated in two aortic centers with the E-nside graft employing the partial deployment technique were included in the study cohort and analyzed. To execute the procedure with partial endograft deployment, the device should be prepared before insertion by advancing, under fluoroscopy, all four dedicated 400 cm long 0.018″ non-hydrophilic guidewires until their proximal ends reach the cranial graft's edge. Anticipating this guidewire placement prevents the inability to do so once the endograft is partially released, avoiding potentially increased friction inside the constricted pre-loaded microchannels. The endograft is then advanced and deployed in the standard fashion, stopping just after the inner branch outlets are fully expanded. Tip capture is released, and the proximal end of the device is opened. Visceral vessel bridging is completed from an upper access in the desired sequence, and the graft is fully released after revascularizing one or more arteries. Preventing the distal edge of the graft from fully expanding improves visceral vessel cannulation and bridging component advancement, especially when dealing with restricted lumina. Results: A total of 26 patients were treated during the period December 2019-March 2024 with the described approach. Procedure was performed in urgent settings in 14/26 cases. The available lumen was narrower than 24 mm at the origin of at least one target vessel in 11 out of 26 cases performed (42.3%). Technical success was obtained in 24 out of 26 cases (92.3%), with failures being due to TVVs loss. No intraoperative death or surgical conversion was recorded, and no early reintervention was needed in the perioperative period. Clinical success at 30 days was therefore 80.7%. Conclusions: The described technique could be considered effective in saving space outside of the graft, allowing for safe navigation and target vessel cannulation in narrow visceral aortas, similar to what has already been reported for outer-branched endografts.
Collapse
Affiliation(s)
- Gioele Simonte
- Vascular and Endovascular Surgery Unit, S. Maria della Misericordia University Hospital, 06132 Perugia, Italy (R.S.)
| | - Emanuele Gatta
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| | - Vincenzo Vento
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| | - Gianbattista Parlani
- Vascular and Endovascular Surgery Unit, S. Maria della Misericordia University Hospital, 06132 Perugia, Italy (R.S.)
| | - Rachele Simonte
- Vascular and Endovascular Surgery Unit, S. Maria della Misericordia University Hospital, 06132 Perugia, Italy (R.S.)
| | - Luca Montecchiani
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| | - Giacomo Isernia
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, 60126 Ancona, Italy; (E.G.); (V.V.); (L.M.); (G.I.)
| |
Collapse
|
9
|
Bisdas T, Zambas N, Zertalis M, Theodorides P, Iatrou N, Dimopoulos C, Charalambous N. Real-World Evaluation of the Off-the-Shelf Precannulated Inner-Branched Endograft for Pararenal Aortic Aneurysms. J Endovasc Ther 2024:15266028241241006. [PMID: 38528651 DOI: 10.1177/15266028241241006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/27/2024]
Abstract
PURPOSE To analyze the early performance and efficacy of the first commercially available off-the-shelf precannulated multibranched endograft in the endovascular repair of pararenal abdominal aortic aneurysms (PAAAs). The device received European marketing approval in late 2020. MATERIALS AND METHODS Between January 2021 and June 2023, a retrospective analysis of prospectively collected data from all consecutive patients with pAAAs undergoing implantation of the E-nside precannulated inner-branched endograft was conducted in 2 centers. The primary outcome measure was technical success defined as the composite endpoint of successful (1) delivery of the 24F endograft, (2) use of the precannulation tubes, and (3) implantation of the bridging stent-grafts (BSGs) to the target vessels. Main secondary endpoints were mortality, target vessel instability (TVI), absence of type I or III endoleak, reintervention, spinal cord ischemia, and supra-celiac aortic coverage. RESULTS Twenty-one patients (20 men, mean age: 71 years) were included in this study with a mean follow-up of 14±7.7 months. Nine patients had a symptomatic aneurysm (43%). Technical success amounted to 95% (in one patient, an iliofemoral conduit was necessary to advance the device). One out of 112 BSGs (1%, right renal artery) occluded at 30 days, resulting in freedom from TVI and reintervention rate at 12 months of 95%. No type I or III endoleaks were identified during follow-up. One patient (5%) died at 13 months due to non-aneurysm-related death, and 1 patient (5%) developed spinal cord ischemia. No other major perioperative complications were observed. Mean supra-celiac aortic coverage reached 52±8%. CONCLUSIONS Given the imperative need for an off-the-shelf endograft tailored to address PAAAs, the E-nside stent-graft demonstrated encouraging outcomes in this study. Nevertheless, it is essential to emphasize that the extent of aortic coverage mandates the production of a truncated variant. CLINICAL IMPACT The endovascular repair of urgent pararenal aortic aneurysms remains still an unsolved problem in the endovascular era since there are no available off-the-shelf dedicated fenestrated or branched endografts. This paper confirms the safety and efficacy of the off-the-shelf precannulated inner branched endograft for this specific indication.
Collapse
Affiliation(s)
- Theodosios Bisdas
- Clinic of Vascular Surgery III, Athens Medical Group, Athens, Greece
- University of Nicosia Medical School, Nicosia, Cyprus
| | - Neophytos Zambas
- Department of Vascular and Interventional Radiology, Aretaeio Hospital, Nicosia, Cyprus
| | - Marios Zertalis
- University of Nicosia Medical School, Nicosia, Cyprus
- Department of Vascular and Interventional Radiology, Aretaeio Hospital, Nicosia, Cyprus
| | | | - Nikolaos Iatrou
- Clinic of Vascular Surgery III, Athens Medical Group, Athens, Greece
| | | | - Nikolas Charalambous
- University of Nicosia Medical School, Nicosia, Cyprus
- Department of Vascular and Interventional Radiology, Aretaeio Hospital, Nicosia, Cyprus
| |
Collapse
|
10
|
Kapalla M, Busch A, Lutz B, Nebelung H, Wolk S, Reeps C. Single-center initial experience with inner-branch complex EVAR in 44 patients. Front Cardiovasc Med 2023; 10:1188501. [PMID: 37396572 PMCID: PMC10309562 DOI: 10.3389/fcvm.2023.1188501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Accepted: 05/16/2023] [Indexed: 07/04/2023] Open
Abstract
Purpose The use of inner-branch aortic stent grafts in the treatment of complex aortic pathologies aims at broad applicability and stable bridging stent sealing compared to other endovascular technologies. The objective of this study was to evaluate the early outcomes with a single manufacturer custom-made and off-the-shelf inner-branched endograft in a mixed patient cohort. Methods This retrospective, monocentric study between 2019 and 2022 included 44 patients treated with inner-branched aortic stent grafts (iBEVAR) as custom-made device (CMD) or off-the-shelf device (E-nside) with at least four inner branches. The primary endpoints were technical and clinical success. Results Overall, 77% (n = 34) and 23% (n = 10) of the patients (mean age 77 ± 6.5 years, n = 36 male) were treated with a custom-made iBEVAR with at least four inner branches and an off-the-shelf graft, respectively. Treatment indications were thoracoabdominal pathologies in 52.2% (n = 23), complex abdominal aneurysms in 25% (n = 11), and type Ia endoleaks in 22.7% (n = 10). Preoperative spinal catheter placement was performed in 27% (n = 12) of patients. Implantation was entirely percutaneous in 75% (n = 33). Technical success was 100%. Target vessel success manifested at 99% (178/180). There was no in-hospital mortality. Permanent paraplegia developed in 6.8% (n = 3) of patients. The mean follow-up was 12 months (range 0-52 months). Three late deaths (6.8%) occurred, one related to an aortic graft infection. Kaplan-Meier estimated 1-year survival manifested at 95% and branch patency at 98% (177/180). Re-intervention was necessary for a total of six patients (13.6%). Conclusions Inner-branch aortic stent grafts provide a feasible option for the treatment of complex aortic pathologies, both elective (custom-made) and urgent (off-the-shelf). The technical success rate is high with acceptable short-term outcomes and moderate re-intervention rates comparable to existing platforms. Further follow-up will evaluate long-term outcomes.
Collapse
Affiliation(s)
- Marvin Kapalla
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Albert Busch
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Brigitta Lutz
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Heiner Nebelung
- Institute and Polyclinic for Diagnostic and Interventional Radiology, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Steffen Wolk
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| | - Christian Reeps
- Department of Visceral, Thoracic and Vascular Surgery, University Hospital Carl Gustav Carus Dresden at the Technical University Dresden, Dresden, Germany
| |
Collapse
|
11
|
Piazza M, Squizzato F, Pratesi G, Tshomba Y, Gaggiano A, Gatta E, Simonte G, Piffaretti G, Frigatti P, Veraldi GF, Silingardi R, Antonello M. Editor's Choice - Early Outcomes of a Novel Off the Shelf Preloaded Inner Branch Endograft for the Treatment of Complex Aortic Pathologies in the ItaliaN Branched Registry of E-nside EnDograft (INBREED). Eur J Vasc Endovasc Surg 2023; 65:811-817. [PMID: 36871927 DOI: 10.1016/j.ejvs.2023.02.076] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2022] [Revised: 02/02/2023] [Accepted: 02/27/2023] [Indexed: 03/06/2023]
Abstract
OBJECTIVE The aim of this study was to investigate the early outcomes of a novel off the shelf pre-loaded inner branched thoraco-abdominal endograft (E-nside) in the treatment of aortic pathologies. METHODS Data from a physician initiated national multicentre registry on patients treated with the E-nside endograft, were prospectively collected and analysed. Pre-operative clinical and anatomical characteristics, procedural data, and early outcomes (90 days) were recorded in a dedicated electronic data capture system. The primary endpoint was technical success. Secondary endpoints were early mortality (90 days), procedural metrics, target vessel patency, endoleak rate, and major adverse events (MAEs) at 90 days. RESULTS In total, 116 patients from 31 Italian centres were included. Mean ± standard deviation (SD) patient age was 73 ± 8 years and 76 (65.5%) were male. Aortic pathologies included degenerative aneurysm in 98 (84.5%), post-dissection aneurysm in five (4.3%), pseudoaneurysm in six (5.2%), penetrating aortic ulcer or intramural haematoma in four (3.4%), and subacute dissection in three (2.6%). Mean ± SD aneurysm diameter was 66 ± 17 mm; aneurysm extent was Crawford I - III in 55 (50.4%), IV in 21 (19.2%), pararenal in 29 (26.7%), and juxtarenal in four (3.7%). The procedure setting was urgent in 25 (21.5%) patients. Median procedural time was 240 minutes (interquartile range [IQR] 195, 303), with a median contrast volume of 175 mL (IQR 120, 235). The endograft's technical success rate was 98.2% and the 90 day mortality rate was 5.2% (n = 6; 2.1% for elective repair and 16% for urgent repair). The 90-days cumulative MAE rate was 24.1% (n = 28). At 90 days, there were 10 (2.3%) target vessel related events (nine occlusions and one type IC endoleak) and one type 1A endoleak requiring re-intervention. CONCLUSION In this real life, non-sponsored registry, the E-nside endograft was used for the treatment of a broad spectrum of aortic pathologies, including urgent cases and different anatomies. The results showed excellent technical implantation safety and efficacy, as well as early outcomes. Longer term follow up is needed to better define the clinical role of this novel endograft.
Collapse
Affiliation(s)
- Michele Piazza
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy.
| | - Francesco Squizzato
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| | - Giovanni Pratesi
- Vascular and Endovascular Surgery Unit, Ospedale Policlinico San Martino, University of Genoa, Genoa, Italy
| | - Yamume Tshomba
- Unit of Vascular Surgery, Fondazione Policlinico Universitario A. Gemelli I.R.C.C.S., Università Cattolica del Sacro Cuore, Rome, Italy
| | - Andrea Gaggiano
- Vascular and Endovascular Surgery Unit, Mauriziano Umberto I Hospital, Turin, Italy
| | - Emanuele Gatta
- Vascular and Endovascular Surgery Unit, Ospedali Riuniti di Ancona, Ancona, Italy
| | - Gioele Simonte
- Unit of Vascular and Endovascular Surgery, Santa Maria della Misericordia Hospital, Perugia, Italy
| | - Gabriele Piffaretti
- Vascular Surgery, Department of Medicine and Surgery, ASST Settelaghi University Teaching Hospital, University of Insubria School of Medicine, Varese, Italy
| | - Paolo Frigatti
- Division of Vascular Surgery, Azienda Sanitaria Universitaria Friuli Centrale, S. Maria della Misericordia University Hospital of Udine, Udine, Italy
| | | | - Roberto Silingardi
- Division of Vascular Surgery, University Hospital of Modena and Reggio Emilia, Baggiovara (MO), Italy
| | - Michele Antonello
- Division of Vascular and Endovascular Surgery, Department of Cardiac, Thoracic, Vascular Sciences and Public Health, University of Padua, Padua, Italy
| |
Collapse
|