Ribas TCF, Nunes MJM, Mesquita RBR, Rangel AOSS. Single flow-based system for the automatic multiparametric nutrients (NPK & Fe) assessment in soil leachates. Talanta 2024; 268:125321. [PMID: 37898034 DOI: 10.1016/j.talanta.2023.125321] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Revised: 10/12/2023] [Accepted: 10/16/2023] [Indexed: 10/30/2023]
Abstract
A multiparametric sequential injection system for the determination of phosphate, nitrite, nitrate, potassium, and iron(III) in a single manifold was developed. The main goal of the proposed method was to develop an efficient tool to assess a number of essential chemical compounds in soils, providing the corresponding information on soil fertility and, additionally, information on possible groundwater contamination. The method was applied for the quantification of the aforementioned parameters in simulated leachates produced in laboratory-scale core columns. The relative standard deviations of ten replicate analyses of a standard were: 6% for phosphate; 2% for nitrite; 2% for nitrate; 5% for potassium; and 6% for iron(III). The limits of detection and quantification were: 2.15 and 7.18 μmol/L for phosphate determination; 0.22 and 0.73 μmol/L for nitrite determination; 3.42 and 8.00 μmol/L for nitrate determination; 39 μmol/L (limit of detection) for potassium determination; and 0.46 and 1.85 μmol/L for iron(III) determination. The sequential injection system was successfully applied for the quantification of multiple soil chemical components (PO43-, NO2-, NO3-, K+, and Fe3+) in soil leachates. The analysis of a sample, involving all the analytes, has a duration of 28 min.
Collapse
Affiliation(s)
- Tânia C F Ribas
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - Maria J M Nunes
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - Raquel B R Mesquita
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal
| | - António O S S Rangel
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005 Porto, Portugal.
| |
Collapse
|
2
|
Mesquita RBR, Moniz T, Nunes MJM, Mesquita LS, Rangel M, Rangel AOSS. Sequential injection method for bi-parametric determination of iron and manganese in soil leachates. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:180-187. [PMID: 34935789 DOI: 10.1039/d1ay01932e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
The aim of this work was to develop a sequential injection (SI) method for the determination of the micronutrients iron and manganese, in soil leachates, as a tool to assess potential groundwater contamination. The described sequential injection method was based on the reaction of iron with chelator MRB12, a greener alternative chromogenic reagent, and the reaction of manganese with zincon, within a single manifold. The developed SI method enabled the determination of iron in the range 0.10-1.00 mg L-1, and manganese in the range 0.25-2.5 mg L-1 with a limit of detection of 0.08 mg L-1 for iron and 0.24 mg L-1 for manganese. The determination of both parameters was made in 6 minutes, in triplicate. The application to monitor laboratory scale soil core columns (LSSCs), as a simulation of the soil leaching process, proved its efficiency to assess potential contamination of ground waters. Iron and manganese contents were effectively analysed in two different scenarios to mimic the leaching process with rainwater and fertilizer.
Collapse
Affiliation(s)
- Raquel B R Mesquita
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
| | - Tânia Moniz
- LAQV, REQUIMTE, Departamento de Química e Bioquímica, Faculdade de Ciências, Universidade do Porto, Rua do Campo Alegre, s/n, 4169-007, Porto, Portugal
| | - Maria J M Nunes
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
| | - Letícia S Mesquita
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
| | - Maria Rangel
- LAQV, REQUIMTE, Instituto de Ciências Biomédicas de Abel Salazar, Universidade do Porto, Rua Jorge Viterbo Ferreira, 228, 4050-313, Porto, Portugal
| | - António O S S Rangel
- Universidade Católica Portuguesa, CBQF - Centro de Biotecnologia e Química Fina - Laboratório Associado, Escola Superior de Biotecnologia, Rua Diogo Botelho 1327, 4169-005, Porto, Portugal.
| |
Collapse
|
3
|
Ferreira FT, Mesquita LS, Mesquita RB, Rangel AO. Improved sequential injection method for phosphate quantification within a wide dynamic range with in-line pre-concentration to monitor soil leachates. TALANTA OPEN 2020. [DOI: 10.1016/j.talo.2020.100015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
4
|
Junsomboon J, Jakmunee J. Determination of potassium, sodium, and total alkalies in portland cement, fly ash, admixtures, and water of concrete by a simple flow injection flame photometric system. JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY 2011; 2011:742656. [PMID: 21747733 PMCID: PMC3124857 DOI: 10.1155/2011/742656] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/31/2011] [Accepted: 04/26/2011] [Indexed: 05/31/2023]
Abstract
A simple flow injection with flame photometric detection has been developed for determination of sodium, potassium, and total alkalies in portland cement, fly ash, admixtures, and water of concrete. A liquid sample or a digest of solid sample was injected into a water carrier stream which flowed to a flame photometer. A change in emission intensity at a selected wavelength was recorded as a peak. An amplifier circuit was fabricated, which helped improve sensitivity of the flame photometer. Calibration graphs in the range of 0.05-1.0 mg L(-1) and 1.0-20.0 mg L(-1) were obtained with a detection limit of 0.02 mg L(-1), for both potassium and sodium determination. Relative standard deviations for 11 replicates of injecting of 10 mg L(-1) potassium and sodium solutions were 1.69 and 1.79%, respectively. Sample throughput of 120 h(-1) was achieved. The proposed method was successfully applied to portland cement, fly ash, admixtures, and water samples validated by the ASTM standard method and certified reference materials of portland cement.
Collapse
Affiliation(s)
- Jaroon Junsomboon
- Physics and Engineering 2 Sub-Division, Physics and Engineering Program, Department of Science Service, Ministry of Science and Technology, Bangkok 10400, Thailand
| | - Jaroon Jakmunee
- Department of Chemistry and Center of Excellence for Innovation in Chemistry, Faculty of Science, Chiang Mai University, Chiang Mai 50200, Thailand
| |
Collapse
|
5
|
Santos JR, Segundo MA, Lima JL, Korn M. Multisyringe flow injection analysis system for automation of standard addition calibration method. Microchem J 2009. [DOI: 10.1016/j.microc.2009.03.006] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
6
|
Feres MA, Fortes PR, Zagatto EA, Santos JL, Lima JL. Multi-commutation in flow analysis: Recent developments and applications. Anal Chim Acta 2008; 618:1-17. [DOI: 10.1016/j.aca.2008.04.039] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2008] [Revised: 04/14/2008] [Accepted: 04/15/2008] [Indexed: 11/30/2022]
|
7
|
|