1
|
Zhang Z, Huang L, Gao F, Zheng Z, Lin Y, Wang S, Wang Q, Wang Q. A ratiometric electrochemical sensor for antiepileptic drug of carbamazepine based on electroactive Ni 2+-terephthalic acid MOF. Talanta 2025; 292:128019. [PMID: 40147083 DOI: 10.1016/j.talanta.2025.128019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2025] [Revised: 03/07/2025] [Accepted: 03/23/2025] [Indexed: 03/29/2025]
Abstract
Carbamazepine (CBZ), an anticonvulsant and mood stabilizer used extensively for epilepsy, requires a reliable and sensitive monitoring assay for assessing and optimizing the dosage administered to epileptic patients. In this work, spherical nickel-based metal-organic framework materials (Ni-MOFs) consisting of nanosheets were synthesized and cast on glassy carbon electrode (GCE) to prepare a novel ratiometric CBZ electrochemical sensor. The electrochemical test results showed that the Ni-MOF-based sensor had a pair of reversible redox peaks at +0.54 V and +0.39 V, respectively, originating from the Ni3+/Ni2+ pair. Meanwhile, CBZ presented an intense irreversible oxidation peak at +1.22 V on the sensor, and its peak current intensity was significantly higher than that on bare GCE and Nafion/GCE. This enhancement can be ascribed to the synergistic effects of the extensive electroactive surface area and the superior electron transfer kinetics of the Ni-MOF, as evidenced by comprehensive physical and electrochemical characterizations. Further, ratiometric sensing detection of CBZ can be achieved by measuring the ratio (R) of oxidation peak currents between CBZ and Ni-MOF, using the Ni-MOF's oxidation peak as the internal reference signal. Under the optimal experimental conditions, the sensor can detect CBZ in the concentration range from 20 to 300 μM with the detection limit as low as 1.03 μM. The recoveries of 94.2-103.3 % were obtained when the sensor was used for the determination of CBZ in serum samples, which demonstrated that the sensor has potential applications in the monitoring of CBZ residues in biological samples.
Collapse
Affiliation(s)
- Zhaoyi Zhang
- Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, 363000, PR China
| | - Ling Huang
- Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, 363000, PR China
| | - Feng Gao
- Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, 363000, PR China; Key Laboratory of Functional Materials and Photoelectrochemistry of Haikou, Hainan Normal University, Haikou, 571158, PR China.
| | - Zhenan Zheng
- Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, 363000, PR China
| | - Yiyang Lin
- Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, 363000, PR China
| | - Sifan Wang
- Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, 363000, PR China
| | - Qinghua Wang
- Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, 363000, PR China
| | - Qingxiang Wang
- Fujian Provincial Key Laboratory of Modern Analytical Science and Separation Technology, College of Chemistry, Chemical Engineering and Environment, Minnan Normal University, Zhangzhou, 363000, PR China.
| |
Collapse
|
2
|
Aaryashree, Choudhary AK, Yoshimi Y. Disposable Sensor Chips with Molecularly Imprinted Carbon Paste Electrodes for Monitoring Anti-Epileptic Drugs. SENSORS (BASEL, SWITZERLAND) 2023; 23:3271. [PMID: 36991982 PMCID: PMC10059048 DOI: 10.3390/s23063271] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2023] [Revised: 03/07/2023] [Accepted: 03/17/2023] [Indexed: 08/12/2023]
Abstract
Epilepsy is a neurological disorder that affects millions of people worldwide. Anti-epileptic drugs (AEDs) are critical for their management. However, the therapeutic window is narrow, and traditional laboratory-based therapeutic drug monitoring (TDM) methods can be time consuming and unsuitable for point-of-care testing. To address this issue, we developed a disposable sensor chip based on molecularly imprinted polymer-modified carbon paste electrodes (MIP-CPs) for the TDM of AEDs such as phenobarbital (PB), carbamazepine (CBZ), and levetiracetam (LEV). In this work, functional monomers (methacrylic acid) and crosslinking monomers (methylene bisacrylamide and ethylene glycol dimethacrylate) were copolymerized in the presence of the AED template and grafted on the graphite particles by simple radical photopolymerization. The grafted particles were mixed with silicon oil, dissolving ferrocene as a redox marker to make the MIP-carbon paste (CP). Disposable sensor chips were fabricated by packing the MIP-CP into the base made of poly (ethylene glycol terephthalate) (PET) film. The sensor's sensitivity was determined using differential pulse voltammetry (DPV), carried out on a single sensor chip for each operation. Linearity was obtained from 0-60 μg/mL in PB and LEV and 0-12 μg/mL in CBZ, covering their respective therapeutic range. The time taken for each measurement was around 2 min. The experiment using whole bovine blood and bovine plasma indicated that the existence of species that interfered had a negligible effect on the test's sensitivity. This disposable MIP sensor provides a promising approach for point-of-care testing and facilitating the management of epilepsy. Compared with existing tests, this sensor offers a faster and more accurate way to monitor AEDs, which is crucial for optimizing therapy and improving patient outcomes. Overall, the proposed disposable sensor chip based on MIP-CPs represents a significant advancement in AED monitoring, with the potential for rapid, accurate, and convenient point-of-care testing.
Collapse
Affiliation(s)
- Aaryashree
- Innovative Global Program, Shibaura Institute of Technology, Toyosu, Koto-City, Tokyo 135-8548, Japan;
| | - Ashish Kumar Choudhary
- Department Applied Chemistry, Shibaura Institute of Technology, Toyosu, Koto-City, Tokyo 135-8548, Japan
| | - Yasuo Yoshimi
- Department Applied Chemistry, Shibaura Institute of Technology, Toyosu, Koto-City, Tokyo 135-8548, Japan
| |
Collapse
|
3
|
Recent advances in electrochemical screening of tricyclic drug carbamazepine: A mini-review. TALANTA OPEN 2022. [DOI: 10.1016/j.talo.2022.100147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022] Open
|
4
|
Mariyappan V, Sundaresan R, Chen SM, Ramachandran R. Ultrasensitive electrochemical sensor for the detection of carbamazepine based on gadolinium vanadate nanostructure decorated functionalized carbon nanofiber nanocomposite. CHEMOSPHERE 2022; 307:135803. [PMID: 35931253 DOI: 10.1016/j.chemosphere.2022.135803] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2022] [Revised: 07/04/2022] [Accepted: 07/19/2022] [Indexed: 06/15/2023]
Abstract
The gadolinium vanadate nanostructure decorated functionalized carbon nanofiber (GdVO4/f-CNF) nanocomposite was prepared by the hydrothermal method, which is fabricated on a glassy carbon electrode (GCE) for the determination of carbamazepine (CBZ). The structural morphology of the hydrothermally synthesized GdVO4/f-CNF material was investigated by several spectroscopy methods such as FESEM, HRTEM, EDS-mapping, XRD, XPS, and Raman. Moreover, the electrical conductivity of our synthesized material was inspected by the electrochemical impedance spectroscopy (EIS) analysis, and the electrochemical performance towards CBZ was inspected by the cyclic voltammetry (CV) and amperometry (AMP) analysis under optimized conditions. The AMP determination of CBZ exhibits the lowest level LOD of 0.0018 μM and a good linear range of 0.01-157 μM. Additionally, our proposed sensor was used to determine the CBZ in the pharmaceutical and, human urine samples which have exposed the acceptable recoveries.
Collapse
Affiliation(s)
- Vinitha Mariyappan
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan
| | - Ruspika Sundaresan
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan
| | - Shen-Ming Chen
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, No.1, Section 3, Chung-Hsiao East Road, Taipei, 106, Taiwan.
| | - Rasu Ramachandran
- Department of Chemistry, The Madura College, Vidya Nagar, Madurai, 625 011, Tamil Nadu, India
| |
Collapse
|
5
|
Chung S, Singh NK, Gribkoff VK, Hall DA. Electrochemical Carbamazepine Aptasensor for Therapeutic Drug Monitoring at the Point of Care. ACS OMEGA 2022; 7:39097-39106. [PMID: 36340178 PMCID: PMC9631757 DOI: 10.1021/acsomega.2c04865] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 09/22/2022] [Indexed: 06/02/2023]
Abstract
Monitoring the anti-epileptic drug carbamazepine (CBZ) is crucial for proper dosing, optimizing a patient's clinical outcome, and managing their medication regimen. Due to its narrow therapeutic window and concentration-related toxicity, CBZ is prescribed and monitored in a highly personalized manner. We report an electrochemical conformation-changing aptasensor with two assay formats: a 30 min assay for routine monitoring and a 5 min assay for rapid emergency testing. To enable "sample-to-answer" testing, a de novo CBZ aptamer (K d < 12 nM) with conformational switching due to a G-quadruplex motif was labeled with methylene blue and immobilized on a gold electrode. The electrode fabrication and detection conditions were optimized using electrochemical techniques and visualized by atomic force microscopy (AFM). The aptasensor performance, including reproducibility, stability, and interference, was characterized using electrochemical impedance spectroscopy and voltammetry techniques. The aptasensor exhibited a wide dynamic range in buffer (10 nM to 100 μM) with limits of detection of 1.25 and 1.82 nM for the 5 and 30 min assays, respectively. The clinical applicability is demonstrated by detecting CBZ in finger prick blood samples (<50 μL). The proposed assays provide a promising method to enable point-of-care monitoring for timely personalized CBZ dosing.
Collapse
Affiliation(s)
- Saeromi Chung
- Department
of Electrical and Computer Engineering, University of California San Diego, La Jolla, California 92093, United States
| | - Naveen K. Singh
- Department
of Electrical and Computer Engineering, University of California San Diego, La Jolla, California 92093, United States
| | | | - Drew A. Hall
- Department
of Electrical and Computer Engineering, University of California San Diego, La Jolla, California 92093, United States
- Department
of Bioengineering, University of California
San Diego, La Jolla, California 92093, United States
| |
Collapse
|
6
|
Abstract
In recent years, wearable sensors have enabled the unique mode of real-time and noninvasive monitoring to develop rapidly in medical care, sports, and other fields. Sweat contains a wide range of biomarkers such as metabolites, electrolytes, and various hormones. Combined with wearable technology, sweat can reflect human fatigue, disease, mental stress, dehydration, and so on. This paper comprehensively describes the analysis of sweat components such as glucose, lactic acid, electrolytes, pH, cortisol, vitamins, ethanol, and drugs by wearable sensing technology, and the application of sweat wearable devices in glasses, patches, fabrics, tattoos, and paper. The development trend of sweat wearable devices is prospected. It is believed that if the sweat collection, air permeability, biocompatibility, sensing array construction, continuous monitoring, self-healing technology, power consumption, real-time data transmission, specific recognition, and other problems of the wearable sweat sensor are solved, we can provide the wearer with important information about their health level in the true sense.
Collapse
|
7
|
Song Z, Zhai X, Jiang C, Chen R, Ye S, Tong J, Dramou P, He H. Sensitive and selective detection of carbamazepine in serum samples by bionic double-antibody sandwich method based on cucurbit[7]uril and molecular imprinted polymers. Biosens Bioelectron 2022; 203:114037. [PMID: 35123315 DOI: 10.1016/j.bios.2022.114037] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 01/20/2022] [Accepted: 01/21/2022] [Indexed: 12/17/2022]
Abstract
A novel bionic enzyme-linked immunosorbent assay (BELISA) based on double-antibody sandwich method is firstly designed for the detection of carbamazepine (CBZ) in human serum samples. In this BELISA system, cucurbit[7]uril (CB[7]) is employed as an artificial capture antibody (cAb), and molecularly imprinted polymers (MIPs) is used as an artificial detection antibody (dAb). Nanozymes (PdNPs) as signal generators are integrated with MIPs. This couple of bionic antibodies exhibits not only the excellent physical and chemical stability, but also the superior molecular recognition ability. Based on two bionic antibodies that can selectively recognize different sites of CBZ molecule, a new BELISA method has been constructed for the first time. The proposed BELISA method displays a good linear relationship ranging from 2 to 20 μg mL-1. The detection limit is 0.37 μg mL-1, which can well meet clinical testing demand. It provides a more stable and economical method for clinical therapeutic drug monitoring (TDM).
Collapse
Affiliation(s)
- Zhaorui Song
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China; Bohai rim Advanced Research Institute for Drug Discovery, Yantai, 264003, Shandong, China
| | - Xinhui Zhai
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Chenrui Jiang
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Rong Chen
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Sijing Ye
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Jinzhe Tong
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China
| | - Pierre Dramou
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China.
| | - Hua He
- Department of Analytical Chemistry, China Pharmaceutical University, Nanjing, 211100, China; Key Laboratory of Biomedical Functional Materials, China Pharmaceutical University, Nanjing, 211100, China; Key Laboratory of Drug Quality Control and Pharmacovigilance, Ministry of Education, China Pharmaceutical University, Nanjing, 211198, China.
| |
Collapse
|
8
|
In situ one-step electrochemical preparation of mesoporous molecularly imprinted sensor for efficient determination of indole-3-acetic acid. J Electroanal Chem (Lausanne) 2022. [DOI: 10.1016/j.jelechem.2021.116000] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
9
|
Ultrasensitive detection and removal of carbamazepine in wastewater using UCNPs functionalized with thin-shell MIPs. Microchem J 2021. [DOI: 10.1016/j.microc.2021.106674] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
10
|
Tarahomi S, Rounaghi GH, Daneshvar L, Eftekhari M. A Carbon Ionic Liquid Paste Sensor Modified with Lanthanum Nanorods /MWCNTs/Nafion Hybrid Composite for Carbamazepine Screening in Biological and Pharmaceutical Media. ChemistrySelect 2021. [DOI: 10.1002/slct.202102600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Somayeh Tarahomi
- Department of Chemistry Faculty of Sciences Ferdowsi University of Mashhad Mashhad Iran
| | | | - Leili Daneshvar
- Department of Chemistry Faculty of Sciences Ferdowsi University of Mashhad Mashhad Iran
| | - Mohammad Eftekhari
- Department of Chemistry Faculty of Sciences Ferdowsi University of Mashhad Mashhad Iran
| |
Collapse
|
11
|
In-situ and controllable synthesis of graphene-gold nanoparticles/molecularly imprinted polymers composite modified electrode for sensitive and selective rutin detection. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105254] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
12
|
Jiang C, Wu T, Liu J, Wang Y. Application of a thermo-sensitive imprinted SERS substrate to the rapid trace detection of ofloxacin. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:4783-4788. [PMID: 32945296 DOI: 10.1039/d0ay00616e] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
A novel composite (AgNPs-MIPs) was prepared by combining nano-silver particles with an ofloxacin (OFL) imprinted thermo-sensitive hydrogel. The thermo-sensitive optical properties of the composite were studied and it was used as a Raman substrate for the detection of ofloxacin. The results have shown that the position and intensity of the plasmon resonance absorption peak of the AgNPs-MIPs can be reversibly changed with the change of temperature, and the intensity of the ofloxacin Raman signal increases with the increase of temperature. Because the hydrogel combined Raman enhancement of silver nanoparticles, the selectivity of molecularly imprinted materials and the intelligent response of thermo-sensitive hydrogels, it can realize rapid, in situ, trace and selective detection of ofloxacin. Moreover, the detection limit can reach 10-10 mol L-1.
Collapse
Affiliation(s)
- Caiyun Jiang
- College of Chemistry and Materials Science, Nanjing Normal University, Nanjing 210023, China.
| | | | | | | |
Collapse
|
13
|
Feroz M, Vadgama P. Molecular Imprinted Polymer Modified Electrochemical Sensors for Small Drug Analysis: Progress to Practical Application. ELECTROANAL 2020. [DOI: 10.1002/elan.202060276] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Momina Feroz
- Institute of Chemistry University of the Punjab 54590 Lahore Pakistan
| | - Pankaj Vadgama
- School of Engineering and Materials Science Queen Mary University of London Mile End Road London E1 4NS United Kingdom
| |
Collapse
|
14
|
Multivariate Optimization of an Ultrasound-Assisted Deep Eutectic Solvent-Based Liquid-Phase Microextraction Method for HPLC–UV Analysis of Carbamazepine in Plasma. Chromatographia 2020. [DOI: 10.1007/s10337-020-03966-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
|
15
|
Ma W, Chang Q, Zhao J, Ye BC. Novel electrochemical sensing platform based on ion imprinted polymer with nanoporous gold for ultrasensitive and selective determination of As 3. Mikrochim Acta 2020; 187:571. [PMID: 32939585 DOI: 10.1007/s00604-020-04552-9] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2020] [Accepted: 09/04/2020] [Indexed: 02/07/2023]
Abstract
An electrochemical sensor has been developed based on ion imprinted polymer (IIP) and nanoporous gold (NPG) modified gold electrode (IIP/NPG/GE) for determination of arsenic ion (As3+) in different kinds of water. NPG with high conductivity, large specific surface area, and high biocompatibility was prepared by a green electrodeposition method. Then a layer of IIP was synthesized in situ on NPG surface by electropolymerization, in which As3+ was used as template ion and o-phenylenediamine as functional monomer. We used potassium ferricyanide and potassium ferrocyanide chelates as electrochemical probes to generate signals. The electrochemical behavior of IIP/NPG/GE (vs. Ag/AgCl) was studied by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). The linear range for As3+ was 2.0 × 10-11 to 9.0 × 10-9 M, and the lower detection limit was 7.1 × 10-12 M (S/N = 3). This newly developed sensor has good stability and selectivity, and has been successfully applied to the As3+ determination of four kinds of water quality.
Collapse
Affiliation(s)
- Wuwei Ma
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi, 832000, China. .,Xinjiang Xiangrun New Material Technology Co. Ltd., Hami, 839000, China.
| | - Qigang Chang
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi, 832000, China.
| | - Jinhu Zhao
- Xinjiang Xiangrun New Material Technology Co. Ltd., Hami, 839000, China
| | - Bang-Ce Ye
- Key Laboratory for Green Processing of Chemical Engineering of Xinjiang Production and Construction Corps, School of Chemistry and Chemical Engineering, Shihezi University, Shihezi, 832000, China
| |
Collapse
|
16
|
Li S, Pang C, Ma X, Li H, Zhao M, Liu C, Luo J. A gold nanoparticle-loaded molecularly imprinted switch sensor with high sensitivity to ethephon. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105025] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
17
|
Veeralingam S, Badhulika S. Two-Dimensional Metallic NiSe 2 Nanoclusters-Based Low-Cost, Flexible, Amperometric Sensor for Detection of Neurological Drug Carbamazepine in Human Sweat Samples. Front Chem 2020; 8:337. [PMID: 32426327 PMCID: PMC7205447 DOI: 10.3389/fchem.2020.00337] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2020] [Accepted: 04/01/2020] [Indexed: 11/19/2022] Open
Abstract
Here we report a low-cost, flexible amperometric sensing platform for highly selective and sensitive detection of carbamazepine (CBZ) in human sweat samples. Detailed morphological characterization of the two-dimensional transition metal dichalcogenide NiSe2, synthesized using one-step hydrothermal method, confirms the formation of dense NiSe2 nanoclusters in the range of 500–650 nm, whereas X-ray diffraction and X-ray photoelectron spectroscopy studies reveal a stable and pure cubic crystalline phase of NiSe2. The sensor device is fabricated by uniformly depositing an optimized weight percentage of as-synthesized NiSe2 onto flexible and biocompatible polyimide substrate using spin coating, and metal contacts are established using thermal evaporation technique. The sensor exhibits a remarkable sensitivity of 65.65 μA/nM over a wide linear range of 50 nM to 10 μM CBZ concentrations and a low limit of detection of 18.2 nM. The sensing mechanism and excellent response of NiSe2 toward CBZ can be attributed to the highly conductive metallic NiSe2, large electroactive surface area of its nanoclusters, and highly interactive Ni2+/Ni3+ oxidation states. Furthermore, the presence of 10-fold excess of capable interferents, such as lactic acid, glucose, uric acid, and ascorbic acid, does not affect the accurate determination of CBZ, thus demonstrating excellent selectivity. The real-time detection of CBZ is evaluated in human sweat samples using standard addition method, which yields reliable results. Furthermore, the sensor shows excellent robustness when subject to bending cycles and fast response time of 2 s. The strategy outlined here is useful in developing sensing platforms at low potential without the use of enzymes or redox binders for applications in healthcare.
Collapse
Affiliation(s)
- Sushmitha Veeralingam
- Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Hyderabad, India
| | - Sushmee Badhulika
- Department of Electrical Engineering, Indian Institute of Technology Hyderabad, Hyderabad, India
| |
Collapse
|
18
|
Yarman A, Scheller FW. How Reliable Is the Electrochemical Readout of MIP Sensors? SENSORS (BASEL, SWITZERLAND) 2020; 20:E2677. [PMID: 32397160 PMCID: PMC7248831 DOI: 10.3390/s20092677] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/14/2020] [Revised: 05/01/2020] [Accepted: 05/06/2020] [Indexed: 01/15/2023]
Abstract
Electrochemical methods offer the simple characterization of the synthesis of molecularly imprinted polymers (MIPs) and the readouts of target binding. The binding of electroinactive analytes can be detected indirectly by their modulating effect on the diffusional permeability of a redox marker through thin MIP films. However, this process generates an overall signal, which may include nonspecific interactions with the nonimprinted surface and adsorption at the electrode surface in addition to (specific) binding to the cavities. Redox-active low-molecular-weight targets and metalloproteins enable a more specific direct quantification of their binding to MIPs by measuring the faradaic current. The in situ characterization of enzymes, MIP-based mimics of redox enzymes or enzyme-labeled targets, is based on the indication of an electroactive product. This approach allows the determination of both the activity of the bio(mimetic) catalyst and of the substrate concentration.
Collapse
Affiliation(s)
- Aysu Yarman
- Institute of Biochemistry and Biology, University of Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam, Germany
| | - Frieder W. Scheller
- Institute of Biochemistry and Biology, University of Potsdam, Karl-Liebknecht-Strasse 24-25, 14476 Potsdam, Germany
| |
Collapse
|
19
|
Li Y, Wang Y, Wang M, Zhang J, Wang Q, Li H. A molecularly imprinted nanoprobe incorporating Cu2O@Ag nanoparticles with different morphologies for selective SERS based detection of chlorophenols. Mikrochim Acta 2019; 187:59. [DOI: 10.1007/s00604-019-4052-y] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 11/27/2019] [Indexed: 11/29/2022]
|