1
|
Bai S, Yang T, Liu P, Tan J, Chen S, Lei H, Wei X. Preparation of a V-COF@SWCNTs-COOH/SPCE supported molecularly imprinted electrochemical sensor for real-time detection of trace sulfadimidine. Talanta 2025; 282:127046. [PMID: 39432958 DOI: 10.1016/j.talanta.2024.127046] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/01/2024] [Revised: 09/27/2024] [Accepted: 10/12/2024] [Indexed: 10/23/2024]
Abstract
To overcome the limitations of insufficient sensitivity and poor specificity of portable screen-printed carbon electrode-electrochemical sensors (SPCE-EC) in practical applications, we prepared carrier composites of carboxylic single-walled carbon nanotubes vertically grafted by covalent organic frameworks (v-COF@SWCNTs-COOH) and coated with a molecularly imprinted polymer (MIP) of sulfadimidine (SM2). 55 °C hot steam elution is more eco-friendly than traditional organic solvent elution. The results showed that when the mass ratio of DBA to DBA-SWCNTs was 1:1, the v-COF@SWCNTs-COOH obtained by the two-step synthesis method could increase the electrical signal up to 2.33-fold of the bare electrode. The bifunctional monomer MIP prepared on the above structure enhanced the signal response by 2.91-fold, with a high imprint factor of 20. The assembled MIP/v-COF@SWCNTs-COOH/SPCE were analyzed by differential pulse voltammetry (DPV) with a high sensitivity of 0.21 nM for LOD and 0.70 nM for LOQ. In milk and fish samples, the recovery rate was 95.0 %-104.8 %. The validation of authentic pork samples with the statutory LC-MS/MS method showed no significant difference (P > 0.05). The sensor's performance indicators remained robust after five repeated uses. Therefore, the MIP/v-COF@SWCNTs-COOH/SPCE combines the cheapness and portability of SPCE, while the sensitivity and specificity of small molecule detection were significantly improved.
Collapse
Affiliation(s)
- Shuomeng Bai
- Guangdong Provincial Key Laboratory of Food Quality and Safety/ National-Local Joint Engineering Research Center for Precision Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China.
| | - Tingting Yang
- Guangdong Provincial Key Laboratory of Food Quality and Safety/ National-Local Joint Engineering Research Center for Precision Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China.
| | - Peiqiao Liu
- Guangdong Provincial Key Laboratory of Food Quality and Safety/ National-Local Joint Engineering Research Center for Precision Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China.
| | - Junhua Tan
- Guangdong Provincial Key Laboratory of Food Quality and Safety/ National-Local Joint Engineering Research Center for Precision Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China.
| | - Shuixie Chen
- Guangdong Provincial Laboratory of Chemistry and Fine Chemical Engineering Jieyang Center, Jieyang, 515200, China.
| | - Hongtao Lei
- Guangdong Provincial Key Laboratory of Food Quality and Safety/ National-Local Joint Engineering Research Center for Precision Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China.
| | - Xiaoqun Wei
- Guangdong Provincial Key Laboratory of Food Quality and Safety/ National-Local Joint Engineering Research Center for Precision Machining and Safety of Livestock and Poultry Products, College of Food Science, South China Agricultural University, Guangzhou, 510642, China; Guangdong Provincial Laboratory of Chemistry and Fine Chemical Engineering Jieyang Center, Jieyang, 515200, China.
| |
Collapse
|
2
|
Dhaffouli A, Holzinger M, Carinelli S, Barhoumi H, Salazar-Carballo PA. ZnO Doped Silica Nanoparticles (ZnO@SiO 2) for Enhanced Electrochemical Detection of Cd 2+ Ions in Real Samples. SENSORS (BASEL, SWITZERLAND) 2024; 24:4179. [PMID: 39000958 PMCID: PMC11244355 DOI: 10.3390/s24134179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2024] [Revised: 06/21/2024] [Accepted: 06/24/2024] [Indexed: 07/16/2024]
Abstract
Pollution by heavy metal ions has a serious impact on human health and the environment, which is why the monitoring of heavy metal ions is of great practical importance. In this work, we describe the development of an electrochemical sensor for the detection of cadmium (Cd2+) involving the doping of porous SiO2 spheres with ZnO nanoparticles. Zinc oxide is chosen as the central dopant in the composite material to increase the conductivity and thus improve the electrochemical detection of Cd2+ ions with the SiO2 spheres. The resulting composite is characterized by electrochemical spectroscopic XRD and microscopic methods. As a result, the developed sensor shows good selectivity towards the targeted Cd2+ ions compared to other divalent ions. After optimization of the experimental conditions, the electrochemical sensor shows two different linear ranges between 2.5 × 10-11 molL-1 to 1.75 × 10-10 molL-1 and 2 × 10-9 molL-1 to 1.75 × 10-9 molL-1, indicating a change from diffusion-controlled to surface-controlled oxidation of Cd2+. A detection limit was reached at 4.4 × 10-11 molL-1. In addition, it offers good repeatability and recovery, and can detect accurate trace amounts of Cd2+ ions in real samples such as tap water or seawater by spiking these samples with known Cd2+ concentrations. This setup also provides satisfactory recovery rates in the range of 89-102%.
Collapse
Affiliation(s)
- Afef Dhaffouli
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences of Monastir, University of Monastir, Monastir 5000, Tunisia
- Department of Chemistry, Faculty of Sciences of Gafsa, University of Gafsa, Gafsa 2100, Tunisia
| | - Michael Holzinger
- Department of Molecular Chemistry UMR CNRS 5250, Grenoble-Alpes University, CEDEX 9, 38058 Grenoble, France
| | - Soledad Carinelli
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, University of La Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain
| | - Houcine Barhoumi
- Laboratory of Interfaces and Advanced Materials, Faculty of Sciences of Monastir, University of Monastir, Monastir 5000, Tunisia
| | - Pedro A Salazar-Carballo
- Laboratory of Sensors, Biosensors and Advanced Materials, Faculty of Health Sciences, University of La Laguna, Campus de Ofra s/n, 38071 La Laguna, Spain
| |
Collapse
|
3
|
Nazim T, Lusina A, Cegłowski M. Recent Developments in the Detection of Organic Contaminants Using Molecularly Imprinted Polymers Combined with Various Analytical Techniques. Polymers (Basel) 2023; 15:3868. [PMID: 37835917 PMCID: PMC10574876 DOI: 10.3390/polym15193868] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2023] [Revised: 09/13/2023] [Accepted: 09/21/2023] [Indexed: 10/15/2023] Open
Abstract
Molecularly imprinted polymers (MIPs) encompass a diverse array of polymeric matrices that exhibit the unique capacity to selectively identify a designated template molecule through specific chemical moieties. Thanks to their pivotal attributes, including exceptional selectivity, extended shelf stability, and other distinct characteristics, this class of compounds has garnered interest in the development of highly responsive sensor systems. As a result, the incorporation of MIPs in crafting distinctive sensors and analytical procedures tailored for specific analytes across various domains has increasingly become a common practice within contemporary analytical chemistry. Furthermore, the range of polymers amenable to MIP formulation significantly influences the potential utilization of both conventional and innovative analytical methodologies. This versatility expands the array of possibilities in which MIP-based sensing can be employed in recognition systems. The following review summarizes the notable progress achieved within the preceding seven-year period in employing MIP-based sensing techniques for analyte determination.
Collapse
Affiliation(s)
| | | | - Michał Cegłowski
- Faculty of Chemistry, Adam Mickiewicz University in Poznań, Uniwersytetu Poznańskiego 8, 61-614 Poznań, Poland; (T.N.); (A.L.)
| |
Collapse
|
4
|
Manivannan B, Nallathambi G, Devasena T. Alternative methods of monitoring emerging contaminants in water: a review. ENVIRONMENTAL SCIENCE. PROCESSES & IMPACTS 2022; 24:2009-2031. [PMID: 36128976 DOI: 10.1039/d2em00237j] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Anthropogenic activities have steadily increased the release of emerging contaminants (ECs) in aquatic bodies, and these ECs may have adverse effects on humans even at their trace (μg L-1) levels. Their occurrence in wastewater systems is more common, and the current wastewater treatment facilities are inefficient in eliminating many of such persistent ECs. "Gold standard" techniques such as chromatography, mass spectrometry, and other high-resolution mass spectrometers are used for the quantification of ECs of various kinds, but they all have significant limitations. This paper reviews the alternative methods for EC detection, which include voltammetry, potentiometry, amperometry, electrochemical impedance spectroscopy (EIS) based electrochemical methods, colorimetry, surface-enhanced Raman spectroscopy (SERS), fluorescence probes, and fluorescence spectroscopy-based optical techniques. These alternative techniques have several advantages over conventional techniques, including low sample volume, excludes solid phase extraction procedure, high sensitivity, selectivity, portability, reproducibility, rapidity, low cost, and the ability to monitor ECs in real time. This review summarises each of the alternative methods for detecting ECs in water samples and their respective limits of detection (LODs). The sensitivity of each technique varied depending on the type of EC measured, type of electrochemical probe and electrode, substrates, type of nanoparticle (NP), the physicochemical parameters of water samples tested, and more. Nevertheless, this paper also focuses on some of the current challenges encountered by these alternative methods in monitoring ECs.
Collapse
Affiliation(s)
| | - Gobi Nallathambi
- Department of Textile Technology, Anna University, Chennai, Tamil Nadu, India.
| | | |
Collapse
|
5
|
Patil VB, Ilager D, Tuwar SM, Mondal K, Shetti NP. Nanostructured ZnO-Based Electrochemical Sensor with Anionic Surfactant for the Electroanalysis of Trimethoprim. BIOENGINEERING (BASEL, SWITZERLAND) 2022; 9:bioengineering9100521. [PMID: 36290489 PMCID: PMC9598839 DOI: 10.3390/bioengineering9100521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/10/2022] [Revised: 09/26/2022] [Accepted: 09/28/2022] [Indexed: 11/06/2022]
Abstract
In this research, detection of trimethoprim (TMP) was carried out using a nanostructured zinc oxide nanoparticle-modified carbon paste electrode (ZnO/CPE) with an anionic surfactant and sodium dodecyl sulphate (SDS) with the help of voltametric techniques. The electrochemical nature of TMP was studied in 0.2 M pH 3.0 phosphate-buffer solution (PBS). The developed electrode displayed the highest peak current compared to nascent CPE. Effects of variation in different parameters, such as pH, immersion time, scan rate, and concentration, were investigated. The electrode process of TMP was irreversible and diffusion controlled with two electrons transferred. The effective concentration range (8.0 × 10-7 M-1.0 × 10-5 M) of TMP was obtained by varying the concentration with a lower limit of detection obtained to be 2.58 × 10-8 M. In addition, this approach was effectively employed in the detection of TMP in pharmaceutical dosages and samples of urine with the excellent recovery data, suggesting the potency of the developed electrode in clinical and pharmaceutical sample analysis.
Collapse
Affiliation(s)
- Vinoda B. Patil
- Department of Chemistry, Karnatak Science College, Dharwad 580001, Karnataka, India
| | - Davalasab Ilager
- Department of Chemistry, K.L.E. Institute of Technology, Hubballi 580027, Karnataka, India
| | - Suresh M. Tuwar
- Department of Chemistry, Karnatak Science College, Dharwad 580001, Karnataka, India
- Correspondence: (S.M.T.); (K.M.); (N.P.S.)
| | - Kunal Mondal
- Idaho National Laboratory, Idaho Falls, ID 83415, USA
- Correspondence: (S.M.T.); (K.M.); (N.P.S.)
| | - Nagaraj P. Shetti
- Department of Chemistry, School of Advanced Sciences, KLE Technological University, Vidyanagar, Hubballi 580031, Karnataka, India
- University Center for Research & Development (UCRD), Chandigarh University, Gharuan, Mohali 140413, Panjab, India
- Correspondence: (S.M.T.); (K.M.); (N.P.S.)
| |
Collapse
|
6
|
Electrochemical Determination of Progesterone in Calf Serum Samples Using a Molecularly Imprinted Polymer Sensor. Microchem J 2022. [DOI: 10.1016/j.microc.2022.108113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
7
|
Zhou S, Liu C, Lin J, Zhu Z, Hu B, Wu L. Towards Development of Molecularly Imprinted Electrochemical Sensors for Food and Drug Safety: Progress and Trends. BIOSENSORS 2022; 12:bios12060369. [PMID: 35735516 PMCID: PMC9221454 DOI: 10.3390/bios12060369] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 05/20/2022] [Accepted: 05/25/2022] [Indexed: 05/31/2023]
Abstract
Due to their advantages of good flexibility, low cost, simple operations, and small equipment size, electrochemical sensors have been commonly employed in food safety. However, when they are applied to detect various food or drug samples, their stability and specificity can be greatly influenced by the complex matrix. By combining electrochemical sensors with molecular imprinting techniques (MIT), they will be endowed with new functions of specific recognition and separation, which make them powerful tools in analytical fields. MIT-based electrochemical sensors (MIECs) require preparing or modifying molecularly imprinted polymers (MIPs) on the electrode surface. In this review, we explored different MIECs regarding the design, working principle and functions. Additionally, the applications of MIECs in food and drug safety were discussed, as well as the challenges and prospects for developing new electrochemical methods. The strengths and weaknesses of MIECs including low stability and electrode fouling are discussed to indicate the research direction for future electrochemical sensors.
Collapse
Affiliation(s)
- Shuhong Zhou
- Key Laboratory of Fermentation Engineering (Ministry of Education), College of Bioengineering and Food, Hubei University of Technology, Wuhan 430068, China; (S.Z.); (J.L.)
| | - Chen Liu
- Leibniz-Institute of Photonic Technology, Leibniz Research Alliance-Leibniz Health Technologies, Albert-Einstein-Str. 9, 07745 Jena, Germany;
| | - Jianguo Lin
- Key Laboratory of Fermentation Engineering (Ministry of Education), College of Bioengineering and Food, Hubei University of Technology, Wuhan 430068, China; (S.Z.); (J.L.)
| | - Zhi Zhu
- Key Laboratory of Tropical and Vegetables Quality and Safety for State Market Regulation, School of Food Science and Engineering, Hainan University, Haikou 570228, China;
| | - Bing Hu
- Key Laboratory of Biotechnology and Bioresources Utilization of Ministry of Education, School of Life Sciences, Dalian Minzu University, Dalian 116600, China;
| | - Long Wu
- Key Laboratory of Fermentation Engineering (Ministry of Education), College of Bioengineering and Food, Hubei University of Technology, Wuhan 430068, China; (S.Z.); (J.L.)
- Key Laboratory of Tropical and Vegetables Quality and Safety for State Market Regulation, School of Food Science and Engineering, Hainan University, Haikou 570228, China;
| |
Collapse
|
8
|
Ben Jaballah M, Ambily Rajendran A, Prieto-Simón B, Dridi C. Development of a sustainable nanosensor using green Cu nanoparticles for simultaneous determination of antibiotics in drinking water. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:2014-2025. [PMID: 35545944 DOI: 10.1039/d2ay00419d] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
In this work, a novel, cost-effective, and eco-friendly electrochemical (EC) nanosensor was fabricated for the simultaneous detection of daptomycin (DAP) and meropenem (MEROP). EC methods have been developed for the determination of antibiotics. In this context, green synthesized copper nanoparticles (CuNPs) using Moringa oleifera plant extract were used as electrode modifiers. The incorporation of CuNPs was proposed to enhance the sensitivity and allow the simultaneous quantification of both antibiotics in water. Transmission electron microscopy (TEM), dynamic light scattering (DLS), attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy, UV-visible spectroscopy, and field emission scanning electron microscopy with energy dispersive X-ray spectroscopy (FESEM-EDX) were employed to characterize CuNPs. Physical adsorption of 20.0 nm (±2.2 nm) spherical CuNPs on the surface of screen-printed carbon electrodes (SPCEs) induced a remarkable electrocatalytic effect. Indeed, the detection of both antibiotics exhibited a limit of detection (LOD) of 0.01 g L-1. The response to various interfering species was assessed. Finally, the quantification of DAP and MEROP in drinking water was demonstrated, confirming the potential of the developed sensor for environmental monitoring applications.
Collapse
Affiliation(s)
- Menyar Ben Jaballah
- NANOMISENE Laboratory, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology CRMN of Sousse Technopole, B.P. 334, Sahloul, Sousse, 4054, Tunisia.
- High School of Sciences and Technology of Hammam Sousse, University of Sousse, Tunisia
| | - Anand Ambily Rajendran
- Department of Electronic Engineering, Universitat Rovira i Virgili, 43007 Tarragona, Spain.
| | - Beatriz Prieto-Simón
- Department of Electronic Engineering, Universitat Rovira i Virgili, 43007 Tarragona, Spain.
- ICREA, Pg. Lluís Companys 23, Barcelona, Spain
| | - Chérif Dridi
- NANOMISENE Laboratory, LR16CRMN01, Centre for Research on Microelectronics and Nanotechnology CRMN of Sousse Technopole, B.P. 334, Sahloul, Sousse, 4054, Tunisia.
| |
Collapse
|
9
|
Sadiq Z, Safiabadi Tali SH, Jahanshahi-Anbuhi S. Gold Tablets: Gold Nanoparticles Encapsulated into Dextran Tablets and Their pH-Responsive Behavior as an Easy-to-Use Platform for Multipurpose Applications. ACS OMEGA 2022; 7:11177-11189. [PMID: 35415343 PMCID: PMC8991920 DOI: 10.1021/acsomega.1c07393] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Accepted: 03/07/2022] [Indexed: 06/14/2023]
Abstract
Many applications using gold nanoparticles (AuNPs) require (i) their functionalization with a biopolymer to increase their stability and (ii) their transformation into an easy-to-handle material, which provide them with specific properties. In this research, a portable tablet platform is presented based on dextran-encapsulated gold nanoparticles (AuNPs-dTab) by a ligand exchange reaction between citrate-capped gold nanoparticles (AuNPs-Cit) and dextran. These newly fabricated tablets were characterized utilizing ultraviolet-visible spectroscopy (UV-vis), Fourier transform infrared spectroscopy-attenuated total reflectance (FTIR-ATR), transmission electron microscopy (TEM), dynamic light scattering (DLS), X-ray diffraction spectroscopy (XRD), differential scanning calorimetry (DSC), and atomic force microscopy (AFM) techniques. The results showed that dextran-capped gold nanoparticles in a tablet platform (AuNPs-dTab) were well-dispersed and highly stable for at least a year at room temperature. In addition to particle and surface characterization of AuNPs-dTab, the tablet morphology in terms of thickness, diameter, density, and opacity was also measured using 6 and 10% dextran with 2, 4 and 8 nM AuNPs-Cit. We further investigated the pH-responsive behavior of AuNPs-dTab in the presence and absence of sodium chloride. Results showed that neutral and alkaline environments were suitable to render AuNPs dispersed in a tablet, while an acidic condition controls the aggregation rate of AuNPs as confirmed by concentration-dependent aggregation phenomena. Besides the easy fabrication, these tablets were portable and low-cost (approx. 1.22 CAD per 100 tablets of a 100 μL solution of dextran-capped gold nanoparticles (AuNPs-dSol)). The biocompatible nature of dextran along with the acidic medium trigger nature of AuNPs makes our proposed tablet a potential candidate for cancer therapy due to the acidic surrounding of tumor tissues as compared to normal cells. Also, our proposed tablet approach paves the way for the fabrication of portable and easy-to-use optical sensors based on the AuNPs embedded in a natural polymeric architecture that would serve as a colorimetric recognition indicator for detecting analytes of interest.
Collapse
Affiliation(s)
- Zubi Sadiq
- Department of Chemical and
Materials Engineering, Gina Cody School of Engineering, Concordia University, Montréal, Québec, H4B 1R6, Canada
| | - Seyed Hamid Safiabadi Tali
- Department of Chemical and
Materials Engineering, Gina Cody School of Engineering, Concordia University, Montréal, Québec, H4B 1R6, Canada
| | - Sana Jahanshahi-Anbuhi
- Department of Chemical and
Materials Engineering, Gina Cody School of Engineering, Concordia University, Montréal, Québec, H4B 1R6, Canada
| |
Collapse
|
10
|
Novel Electrochemical Sensor Based on Molecularly Imprinted Polymers with MWCNTs-SiO2 for Selective and Sensitive Detecting 2,4-D. J Inorg Organomet Polym Mater 2022. [DOI: 10.1007/s10904-021-02154-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
|
11
|
Analysis of brominated flame retardants in the aquatic environment: a review. Arh Hig Rada Toksikol 2021; 72:254-267. [PMID: 34985845 PMCID: PMC8785114 DOI: 10.2478/aiht-2021-72-3576] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2021] [Accepted: 11/01/2021] [Indexed: 11/20/2022] Open
Abstract
The most common and consequently analysed brominated flame retardants (BFRs) are polybrominated biphenyls (PBBs), polybrominated diphenyl ethers (PBDEs), tetrabromobisphenol A (TBBPA), tetrabromobisphenol S (TBBPS), and hexabromocyclododecane (HBCD). As these persistent organic pollutants are widespread in the environment and have a number of harmful effects on human health, the production and use of most has been banned for several years. The aquatic environment is polluted by these compounds through their deposition from the atmosphere, sewage sludge, wastewater treatment plants, and landfills, and higher levels are found in areas with developed industry and agriculture and near landfills. Each compound also seems to show preference for specific compartments of the aquatic environment, i.e. water, sediment, or aquatic organisms, according to their physicochemical properties. The aim of this review was to take a closer look at the analysis of BFRs, as without reliable analysis we would not be able to determine their levels and distribution across the aquatic compartments and assess human exposure and health risks. Particularly worrying are the health risks associated with PBDEs in fish, whose levels generally exceed the permitted values.
Collapse
|
12
|
Hassan MH, Khan R, Andreescu S. Advances in electrochemical detection methods for measuring contaminants of emerging concerns. ELECTROCHEMICAL SCIENCE ADVANCES 2021. [DOI: 10.1002/elsa.202100184] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Affiliation(s)
- Mohamed H. Hassan
- Department of Chemistry and Biomolecular Science Clarkson University Potsdam New York USA
| | - Reem Khan
- Department of Chemistry and Biomolecular Science Clarkson University Potsdam New York USA
| | - Silvana Andreescu
- Department of Chemistry and Biomolecular Science Clarkson University Potsdam New York USA
| |
Collapse
|
13
|
A hybrid monolithic column based on flower-shaped zeolitic imidazolate framework for efficient capillary microextraction of brominated flame retardants. CHINESE CHEM LETT 2021. [DOI: 10.1016/j.cclet.2021.03.034] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
14
|
Huang W, Liu Y, Wang N, Song G, Yin X, Zhang L, Ni X, Xu W. A Sensitive Electrochemical Sensor Based on Ion Imprinted Polymers with Gold Nanoparticles for High Selective Detecting Cd (II) Ions in Real Samples. J Inorg Organomet Polym Mater 2021. [DOI: 10.1007/s10904-021-01892-8] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
|
15
|
A Magnetic, Core–Shell Structured, pH-Responsive Molecularly Imprinted Polymers for the Selective Detection of Sulfamethoxazole. J Inorg Organomet Polym Mater 2021. [DOI: 10.1007/s10904-021-01893-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
16
|
Kaya SI, Cetinkaya A, Ozkan SA. Latest Advances in Determination of Bisphenols with Nanomaterials, Molecularly Imprinted Polymers and Aptamer Based Electrochemical Sensors. Crit Rev Anal Chem 2021; 52:1223-1243. [PMID: 33475425 DOI: 10.1080/10408347.2020.1864719] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
Contamination of environmental sources such as soils, sediments and rivers and human exposure caused by several endocrine disrupting compounds (EDCs) are considered as the most challenging issues of today's world. EDCs cover a wide variety of compounds ranging from phthalates to parabens and bisphenols (BPs) are the leading group among them. BPs are widely used during the production of different plastic materials such as food and beverage containers, toys, medical equipment and baby bottles that we use in every aspect of our lives. BPs may migrate from those products to different media under certain conditions and this situation causes chronic exposure for humans and other creatures in the environment. Especially bisphenol A (BPA) and its other analogues such as bisphenol F, bisphenol S and tetrabromobisphenol that have similar structures and are preferred as alternatives to BPA cause harmful adverse effects such as endocrine disruption, neurotoxicity, genotoxicity and cytotoxicity. There are legal restrictions and prohibitions by the European Union (EU) in order to prevent possible harmful effects. Therefore, it is important to develop highly sensitive, fast, easy to use and cheap sensors for the determination of BPs in biological, environmental and commercial samples. Electrochemical sensors, which are one of the most widely, used analytical techniques, provide these conditions. Additionally, it is possible to enhance the performance of electrochemical sensors with nanomaterials, molecularly imprinted polymers or aptamer based technologies. This review aims to give comprehensive information about BPs with summarizing most recent applications of electrochemical sensors for their determination in different samples.
Collapse
Affiliation(s)
- S Irem Kaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey.,Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Ankara, Turkey
| |
Collapse
|
17
|
Molecularly imprinted polymer-based electrochemical sensors for environmental analysis. Biosens Bioelectron 2020; 172:112719. [PMID: 33166805 DOI: 10.1016/j.bios.2020.112719] [Citation(s) in RCA: 118] [Impact Index Per Article: 23.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2020] [Revised: 10/07/2020] [Accepted: 10/10/2020] [Indexed: 12/11/2022]
Abstract
The ever-increasing presence of contaminants in environmental waters is an alarming issue, not only because of their harmful effects in the environment but also because of their risk to human health. Pharmaceuticals and pesticides, among other compounds of daily use, such as personal care products or plasticisers, are being released into water bodies. This release mainly occurs through wastewater since the treatments applied in many wastewater treatment plants are not able to completely remove these substances. Therefore, the analysis of these contaminants is essential but this is difficult due to the great variety of contaminating substances. Facing this analytical challenge, electrochemical sensing based on molecularly imprinted polymers (MIPs) has become an interesting field for environmental monitoring. Benefiting from their superior chemical and physical stability, low-cost production, high selectivity and rapid response, MIPs combined with miniaturized electrochemical transducers offer the possibility to detect target analytes in-situ. In most reports, the construction of these sensors include nanomaterials to improve their analytical characteristics, especially their sensitivity. Moreover, these sensors have been successfully applied in real water samples without the need of laborious pre-treatment steps. This review provides a general overview of electrochemical MIP-based sensors that have been reported for the detection of pharmaceuticals, pesticides, heavy metals and other contaminants in water samples in the past decade. Special attention is given to the construction of the sensors, including different functional monomers, sensing platforms and materials employed to achieve the best sensitivity. Additionally, several parameters, such as the limit of detection, the linear concentration range and the type of water samples that were analysed are compiled.
Collapse
|
18
|
Zhang K, Kwabena AS, Wang N, Lu Y, Cao Y, Luan Y, Liu T, Peng H, Gu X, Xu W. Electrochemical assays for the detection of TBBPA in plastic products based on rGO/AgNDs nanocomposites and molecularly imprinted polymers. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114022] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|