1
|
Bao Q, Li G, Yang Z, Wei J, Cheng W, Qu Z, Lin L. A Time-Division Multiplexing Multi-Channel Micro-Electrochemical Workstation with Carbon-Based Material Electrodes for Online L-Trosine Detection. SENSORS (BASEL, SWITZERLAND) 2023; 23:6252. [PMID: 37514547 PMCID: PMC10386381 DOI: 10.3390/s23146252] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 07/02/2023] [Accepted: 07/07/2023] [Indexed: 07/30/2023]
Abstract
In the background of the rapid development of artificial intelligence, big data, IoT, 5G/6G, and other technologies, electrochemical sensors pose higher requirements for high-throughput detection. In this study, we developed a workstation with up to 10 channels, which supports both parallel signal stimulation and online electrochemical analysis functions. The platform was wired to a highly integrated Bluetooth chip used for wireless data transmission and can be visualized on a smartphone. We used this electrochemical test platform with carbon-graphene oxide/screen-printed carbon electrodes (CB-GO/SPCE) for the online analysis of L-tyrosine (Tyr), and the electrochemical performance and stability of the electrodes were examined by differential pulse voltammetry (DPV). The CB-GO-based screen-printed array electrodes with a multichannel electrochemical platform for Tyr detection showed a low detection limit (20 μM), good interference immunity, and 10-day stability in the range of 20-200 μM. This convenient electrochemical analytical device enables high-throughput detection and has good economic benefits that can contribute to the improvement of the accuracy of electrochemical analysis and the popularization of electrochemical detection methods in a wide range of fields.
Collapse
Affiliation(s)
- Qiwen Bao
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Gang Li
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| | - Zhengchun Yang
- School of Electrical and Electronic Engineering, Tianjin Key Laboratory of Film Electronic & Communication Devices, Advanced Materials and Printed Electronics Center, Tianjin University of Technology, Tianjin 300384, China
| | - Jun Wei
- School of Materials Science and Engineering, Harbin Institute of Technology, Shenzhen 518055, China
| | - Wenbo Cheng
- Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou 215163, China
| | - Zilian Qu
- Beijing Information Technol Coll, Beijing 100015, China
| | - Ling Lin
- School of Precision Instrument and Optoelectronic Engineering, the State Key Laboratory of Precision Measuring Technology and Instruments, Tianjin University, 92 Weijin Road, Tianjin 300072, China
| |
Collapse
|
2
|
Gou H, He J, Nie R, Xu D, Rao H, Zhao G. A Stable Electrochemical Chiral Interface based on Graphene-chitosan Composites for Tyrosine Enantiomers Recognition. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
3
|
Salinas G, Niamlaem M, Kuhn A, Arnaboldi S. Recent Advances in Electrochemical Transduction of Chiral Information. Curr Opin Colloid Interface Sci 2022. [DOI: 10.1016/j.cocis.2022.101626] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
4
|
Ma C, Xu P, Chen H, Cui J, Guo M, Zhao J. An electrochemical sensor based on reduced graphene oxide/β-cyclodextrin/multiwall carbon nanotubes/ polyoxometalate tetracomponent hybrid: Simultaneous determination of ascorbic acid, dopamine and uric acid. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107533] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
5
|
Ding Z, Zhao J, Hao Z, Guo M, Li L, Li N, Sun X, Zhang P, Cui J. Simultaneous electrochemical determination of nitrophenol isomers based on macroporous carbon functionalized with amino-bridged covalent organic polycalix[4]arenes. JOURNAL OF HAZARDOUS MATERIALS 2022; 423:127034. [PMID: 34481393 DOI: 10.1016/j.jhazmat.2021.127034] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 07/30/2021] [Accepted: 08/23/2021] [Indexed: 06/13/2023]
Abstract
A glassy carbon electrode (GCE) modified by a hybrid, macroporous carbon (MPC) functionalized with triazine bridged covalent organic polycalix[4]arenes (CalCOP) (CalCOP-MPC), has been fabricated and utilized for simultaneous detection of nitrophenols (NP). The obtained CalCOP-MPC were characterized by scanning electron microscope (SEM), transmission electron microscope (TEM), thermogravimetric analysis (TGA), Fourier transform infrared spectroscopy (FTIR), Raman spectroscopy, X-ray photoelectron spectroscopy (XPS), cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS), which confirmed that MPC had functionalized with CalCOP successfully. Benefiting from the synergistic supramolecular effect of macrocyclic receptor of CalCOP and the excellent electrical properties of MPC, the anodic peaks of o-nitrophenol (o-NP), m-nitrophenol (m-NP), and p-nitrophenol (p-NP) in their mixture can be well separated by the prepared electrode. Differential pulse voltammetry (DPV) measurements at CalCOP-MPC/GCE revealed that the linear ranges of NP isomers were all 1-400 μM, and the detection limit limits were 0.383 μM, 0.122 μM, and 0.212 μM for o-NP, m-NP, and p-NP, respectively. Moreover, the prepared modified electrodes showed a relatively good selectivity and stability, implying the prospect for detecting NP in real environmental samples.
Collapse
Affiliation(s)
- Zhiyuan Ding
- College of Chemical Engineering and Materials Science, Tianjin University of Science & Technology, Tianjin 300457, China
| | - Jin Zhao
- College of Chemical Engineering and Materials Science, Tianjin University of Science & Technology, Tianjin 300457, China.
| | - Zelin Hao
- College of Chemical Engineering and Materials Science, Tianjin University of Science & Technology, Tianjin 300457, China
| | - Minjie Guo
- College of Chemical Engineering and Materials Science, Tianjin University of Science & Technology, Tianjin 300457, China
| | - Liang Li
- School of Chemical and Environmental Engineering, Shanghai Institute of Technology, 100 Haiquan Road, Shanghai 201418, China.
| | - Nan Li
- State Key Laboratory of Separation Membranes and Membrane Processes, School of Textile Science and Engineering, Tiangong University, Tianjin 300387, China.
| | - Xuyang Sun
- Sinopec Shanghai Research Institute of Petrochemical Technology, Shanghai 201208, China
| | - Peibin Zhang
- Sinopec Shanghai Research Institute of Petrochemical Technology, Shanghai 201208, China
| | - Jing Cui
- Sinopec Shanghai Research Institute of Petrochemical Technology, Shanghai 201208, China
| |
Collapse
|
6
|
Jia Y, Shang N, He X, Nsabimana A, Gao Y, Ju J, Yang X, Zhang Y. Electrocatalytically active cuprous oxide nanocubes anchored onto macroporous carbon composite for hydrazine detection. J Colloid Interface Sci 2022; 606:1239-1248. [PMID: 34492462 DOI: 10.1016/j.jcis.2021.08.154] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Revised: 08/23/2021] [Accepted: 08/24/2021] [Indexed: 01/24/2023]
Abstract
Cuprous oxide (Cu2O) is a p-type semiconductor with excellent catalytic activity and stability that has gained much attention because it is non-toxic, abundant, and inexpensive. Porous carbon materials have large specific surface areas, which offer abundant electroactive sites, enhance the electrical conductivity of materials, and prevent the aggregation of Cu2O nanocubes. In this study, a composite with high electrocatalytic activity was prepared based on Cu2O nanocubes anchored onto three-dimensional macroporous carbon (MPC) by a simple, eco-friendly, and cheap method for hydrazine detection. Due to the synergistic effect of MPC and Cu2O, the sensor exhibited high electrocatalytic activity, sensitivity, better selectivity, and low limit of detection. The resulting sensor could be a sensitive and effective platform for detecting hydrazine and promising practical applications.
Collapse
Affiliation(s)
- Yanan Jia
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Environmental Science, Institute of Life Science and Green Development, Hebei University, Baoding 071002, PR China
| | - Ningzhao Shang
- College of Science, Hebei Agricultural University, Baoding 071001, PR China
| | - Xiaobo He
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Environmental Science, Institute of Life Science and Green Development, Hebei University, Baoding 071002, PR China
| | - Anaclet Nsabimana
- Chemistry Department, College of Science and Technology, University of Rwanda, Po Box: 3900, Kigali, Rwanda
| | - Yongjun Gao
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Environmental Science, Institute of Life Science and Green Development, Hebei University, Baoding 071002, PR China
| | - Jian Ju
- Wenzhou Institute, University of Chinese Academy of Sciences, Wenzhou, Zhejiang 325000, China
| | - Xinjian Yang
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Environmental Science, Institute of Life Science and Green Development, Hebei University, Baoding 071002, PR China
| | - Yufan Zhang
- Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Environmental Science, Institute of Life Science and Green Development, Hebei University, Baoding 071002, PR China.
| |
Collapse
|
7
|
Niu Q, Jin P, Huang Y, Fan L, Zhang C, Yang C, Dong C, Liang W, Shuang S. A selective electrochemical chiral interface based on a carboxymethyl-β-cyclodextrin/Pd@Au nanoparticles/3D reduced graphene oxide nanocomposite for tyrosine enantiomer recognition. Analyst 2022; 147:880-888. [DOI: 10.1039/d1an02262h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Palladium@gold nanoparticle modified three-dimensional-reduced graphene oxide was coupled with carboxymethyl-β-cyclodextrin to form a novel nanocomposite, which served as an effective chiral sensing interface for electrochemical enantiorecognition.
Collapse
Affiliation(s)
- Qingfang Niu
- Institute of Environmental Science, Department of Chemistry, Shanxi University, Taiyuan, 030006, China
| | - Pengyue Jin
- Key Laboratory of Green Chemistry & Technology of Ministry of Education, College of Architecture and Environment, Sichuan University, Chengdu, 610064, China
| | - Yu Huang
- Institute of Environmental Science, Department of Chemistry, Shanxi University, Taiyuan, 030006, China
| | - Lifang Fan
- Institute of Environmental Science, Department of Chemistry, Shanxi University, Taiyuan, 030006, China
| | - Caihong Zhang
- Institute of Environmental Science, Department of Chemistry, Shanxi University, Taiyuan, 030006, China
| | - Cheng Yang
- Key Laboratory of Green Chemistry & Technology of Ministry of Education, College of Architecture and Environment, Sichuan University, Chengdu, 610064, China
| | - Chuan Dong
- Institute of Environmental Science, Department of Chemistry, Shanxi University, Taiyuan, 030006, China
| | - Wenting Liang
- Institute of Environmental Science, Department of Chemistry, Shanxi University, Taiyuan, 030006, China
| | - Shaomin Shuang
- Institute of Environmental Science, Department of Chemistry, Shanxi University, Taiyuan, 030006, China
| |
Collapse
|
8
|
Moulaee K, Neri G. Electrochemical Amino Acid Sensing: A Review on Challenges and Achievements. BIOSENSORS 2021; 11:502. [PMID: 34940259 PMCID: PMC8699811 DOI: 10.3390/bios11120502] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Revised: 11/18/2021] [Accepted: 11/25/2021] [Indexed: 05/05/2023]
Abstract
The rapid growth of research in electrochemistry in the last decade has resulted in a significant advancement in exploiting electrochemical strategies for assessing biological substances. Among these, amino acids are of utmost interest due to their key role in human health. Indeed, an unbalanced amino acid level is the origin of several metabolic and genetic diseases, which has led to a great need for effective and reliable evaluation methods. This review is an effort to summarize and present both challenges and achievements in electrochemical amino acid sensing from the last decade (from 2010 onwards) to show where limitations and advantages stem from. In this review, we place special emphasis on five well-known electroactive amino acids, namely cysteine, tyrosine, tryptophan, methionine and histidine. The recent research and achievements in this area and significant performance metrics of the proposed electrochemical sensors, including the limit of detection, sensitivity, stability, linear dynamic range(s) and applicability in real sample analysis, are summarized and presented in separate sections. More than 400 recent scientific studies were included in this review to portray a rich set of ideas and exemplify the capabilities of the electrochemical strategies to detect these essential biomolecules at trace and even ultra-trace levels. Finally, we discuss, in the last section, the remaining issues and the opportunities to push the boundaries of our knowledge in amino acid electrochemistry even further.
Collapse
Affiliation(s)
- Kaveh Moulaee
- Department of Engineering, University of Messina, C.Da Di Dio, I-98166 Messina, Italy;
- Center of Excellence in Electrochemistry, School of Chemistry, College of Science, University of Tehran, Tehran 16846-13114, Iran
| | - Giovanni Neri
- Department of Engineering, University of Messina, C.Da Di Dio, I-98166 Messina, Italy;
| |
Collapse
|
9
|
Simultaneous determination of nitrophenol isomers based on reduced graphene oxide modified with sulfobutylether-β-cyclodextrin. Carbohydr Polym 2021; 271:118446. [PMID: 34364581 DOI: 10.1016/j.carbpol.2021.118446] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2021] [Revised: 06/29/2021] [Accepted: 07/12/2021] [Indexed: 12/11/2022]
Abstract
The present study reports the development of an electrochemical sensor based on sulfobutylether-β-cyclodextrin modified reduced graphene oxide hybrid (SBCD-rGO) for simultaneous detection of nitrophenol isomers. First, SBCD-rGO hybrid was synthesized and detailed characterized. Afterwards, a sensor was fabricated via the modification of glassy carbon electrode (GCE) with SBCD-rGO, and its electrochemical detection performances were also investigated. Then, the constructed electrochemical sensor was applied to detect nitrophenol isomers by voltammetry analysis. The results suggested that the sensitivities were 389.26, 280.88 and 217.19 μA/mM for p-nitrophenol (p-NP), m-nitrophenol (m-NP), and o-nitrophenol (o-NP), respectively, and their corresponding detection limits were all about 0.05 μM. Significantly, the combination of voltammetry analysis with the constructed sensor and data analysis by multiple linear regression realized the simultaneous detection of nitrophenol isomers.
Collapse
|