Qiu Y, Dai K, Zhong S, Chen S, Wang C, Chen H, Frydman L, Zhang Z. Spatiotemporal encoding MRI in a portable low-field system. Magn Reson Med 2024. [PMID: 38623991 DOI: 10.1002/mrm.30104] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 03/18/2024] [Accepted: 03/19/2024] [Indexed: 04/17/2024]
Abstract
PURPOSE Demonstrate the potential of spatiotemporal encoding (SPEN) MRI to deliver largely undistorted 2D, 3D, and diffusion weighted images on a 110 mT portable system. METHODS SPEN's quadratic phase modulation was used to subsample the low-bandwidth dimension of echo planar acquisitions, delivering alias-free images with an enhanced immunity to image distortions in a laboratory-built, low-field, portable MRI system lacking multiple receivers. RESULTS Healthy brain images with different SPEN time-bandwidth products and subsampling factors were collected. These compared favorably to EPI acquisitions including topup corrections. Robust 3D and diffusion weighted SPEN images of diagnostic value were demonstrated, with 2.5 mm isotropic resolutions achieved in 3 min scans. This performance took advantage of the low specific absorption rate and relative long TEs associated with low-field MRI. CONCLUSION SPEN MRI provides a robust and advantageous fast acquisition approach to obtain faithful 3D images and DWI data in low-cost, portable, low-field systems without parallel acceleration.
Collapse
Affiliation(s)
- Yueqi Qiu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai, People's Republic of China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Ke Dai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Sijie Zhong
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai, People's Republic of China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Suen Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai, People's Republic of China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Changyue Wang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Hao Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai, People's Republic of China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| | - Lucio Frydman
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Zhiyong Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, People's Republic of China
- National Engineering Research Center of Advanced Magnetic Resonance Technologies for Diagnosis and Therapy (NERC-AMRT), Shanghai Jiao Tong University, Shanghai, People's Republic of China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, People's Republic of China
| |
Collapse
|
2
|
Chen H, Dai K, Bao J, Zhong S, Hu C, Liu Y, Zhang Z. Pseudo multishot echo-planar imaging for geometric distortion improvement. NMR IN BIOMEDICINE 2023; 36:e4885. [PMID: 36454107 DOI: 10.1002/nbm.4885] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 11/21/2022] [Accepted: 11/24/2022] [Indexed: 06/17/2023]
Abstract
Conventional echo-planar imaging (EPI) uses a radiofrequency pulse for excitation and a prolonged echo train to sample k space, while off-resonance and T2 * decay effects caused by magnetic susceptibility variation accumulate within each echo, leading to geometric distortion. Multishot EPI methods, which divide k space into segments, can shorten the effective echo spacing and reduce the distortion on EPI images. But multiple shots cost longer scan time and render susceptibility to motion. In this study, we propose a new "multishot" EPI method termed pseudo multishot EPI (pmsEPI), in which phase-encoding lines are segmented as in multishot EPI but are collected within a single shot. With the magnetization divided into different pathways via interleaved excitation instead of refocusing in a single long echo train, the total phase error accumulation is reduced in each segmented acquisition, thereby improving distortion of the resultant EPI image. The performance of the pmsEPI method is demonstrated by phantom and in vivo brain experiments on a 3-T scanner. The experimental results show that the distortion displacements of pmsEPI acquisition compared with conventional EPI decrease by 50% with two pseudo shots and 66% with three pseudo shots, validating the ability of the method to obtain images with reduced distortion in a single shot, although magnetization splitting may induce more than 40% SNR loss and minor artifacts. Specifically, the ability of pmsEPI in diffusion-weighted imaging with different trajectory options is highlighted, and the flexibility is demonstrated in a single-shot blip up and down acquisition.
Collapse
Affiliation(s)
- Hao Chen
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
| | - Ke Dai
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Jianfeng Bao
- Functional Magnetic Resonance and Molecular Imaging Key Laboratory of Henan Province, The First Affiliated Hospital of Zhengzhou University, Zhengzhou, China
| | - Sijie Zhong
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Chenxi Hu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Yiling Liu
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
| | - Zhiyong Zhang
- School of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, China
- Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China
| |
Collapse
|
3
|
Franklin SL, Schuurmans M, Otikovs M, Borman PTS, van Osch MJP, Bos C. Arterial spin labeling using spatio-temporal encoding readout for robust perfusion imaging in inhomogenous magnetic fields. Magn Reson Med 2023; 89:1092-1101. [PMID: 36420871 PMCID: PMC10099794 DOI: 10.1002/mrm.29506] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 10/10/2022] [Accepted: 10/10/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE To evaluate the feasibility of spatio-temporal encoding (SPEN) readout for pseudo-continuous ASL (pCASL) in brain, and its robustness to susceptibility artifacts as introduced by aneurysm clips. METHODS A 2D self-refocused T2 *-compensated hybrid SPEN scheme, with super-resolution reconstruction was implemented on a 1.5T Philips system. Q (=BWchirp *Tchirp ) was varied and, the aneurysm clip-induced artifact was evaluated in phantom (label-images) as well as in vivo (perfusion-weighted signal (PWS)-maps and temporal SNR (tSNR)). In vivo results were compared to gradient-echo EPI (GE-EPI) and spin-echo EPI (SE-EPI). The dependence of tSNR on TR was evaluated separately for SPEN and SE-EPI. SPEN with Q ˜ 75 encodes with the same off-resonance robustness as EPI. RESULTS The clip-induced artifact with SPEN decreased with increase in Q, and was smaller compared to SE-EPI and GE-EPI in vivo. tSNR decreased with Q and the tSNR of GE-EPI and SE-EPI corresponded to SPEN with a Q-value of approximately ˜85 and ˜108, respectively. In addition, SPEN perfusion images showed a higher tSNR (p < 0.05) for TR = 4000 ms compared to TR = 2100 ms, while SE-EPI did not. tSNR remained relatively stable when the time between SPEN-excitation and start of the next labeling-module was more than ˜1000 ms. CONCLUSION Feasibility of combining SPEN with pCASL imaging was demonstrated, enabling cerebral perfusion measurements with a higher robustness to field inhomogeneity (Q > 75) compared to SE-EPI and GE-EPI. However, the SPEN chirp-pulse saturates incoming blood, thereby reducing pCASL labeling efficiency of the next acquisition for short TRs. Future developments are needed to enable 3D scanning.
Collapse
Affiliation(s)
- Suzanne L Franklin
- Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands.,C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Megan Schuurmans
- Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Martins Otikovs
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Pim T S Borman
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Matthias J P van Osch
- C.J. Gorter Center for High Field MRI, Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands.,Leiden Institute for Brain and Cognition, Leiden University, Leiden, The Netherlands
| | - Clemens Bos
- Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
4
|
Ryu JK, Jung WB, Yu J, Son JP, Lee SK, Kim SG, Park JY. An equal-TE ultrafast 3D gradient-echo imaging method with high tolerance to magnetic susceptibility artifacts: Application to BOLD functional MRI. Magn Reson Med 2020; 85:1986-2000. [PMID: 33107102 DOI: 10.1002/mrm.28564] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Revised: 09/24/2020] [Accepted: 10/01/2020] [Indexed: 12/26/2022]
Abstract
PURPOSE To develop an ultrafast 3D gradient echo-based MRI method with constant TE and high tolerance to B0 inhomogeneity, dubbed ERASE (equal-TE rapid acquisition with sequential excitation), and to introduce its use in BOLD functional MRI (fMRI). THEORY AND METHODS Essential features of ERASE, including spin behavior, were characterized, and a comparison study was conducted with conventional EPI. To demonstrate high tolerance to B0 inhomogeneity, in vivo imaging of the mouse brain with a fiber-optic implant was performed at 9.4 T, and human brain imaging (including the orbitofrontal cortex) was performed at 3 T and 7 T. To evaluate the performance of ERASE in BOLD-fMRI, the characteristics of SNR and temporal SNR were analyzed for in vivo rat brains at 9.4 T in comparison with multislice gradient-echo EPI. Percent signal changes and t-scores are also presented. RESULTS For both mouse brain and human brain imaging, ERASE exhibited a high tolerance to magnetic susceptibility artifacts, showing much lower distortion and signal dropout, especially in the regions involving large magnetic susceptibility effects. For BOLD-fMRI, ERASE provided higher temporal SNR and t-scores than EPI, but exhibited similar percent signal changes in in vivo rat brains at 9.4 T. CONCLUSION When compared with conventional EPI, ERASE is much less sensitive, not only to EPI-related artifacts such as Nyquist ghosting, but also to B0 inhomogeneity including magnetic susceptibility effects. It is promising for use in BOLD-fMRI, providing higher temporal SNR and t-scores with constant TE when compared with EPI, although further optimization is needed for human fMRI.
Collapse
Affiliation(s)
- Jae-Kyun Ryu
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.,Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea.,Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| | - Won Beom Jung
- Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea
| | - Jaeyong Yu
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.,Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| | - Jeong Pyo Son
- Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea.,Department of Health Sciences and Technology, Samsung Advanced Institute for Health Sciences and Technology, Sungkyunkwan University, Seoul, Republic of Korea
| | - Seung-Kyun Lee
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.,Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea.,Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| | - Seong-Gi Kim
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.,Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea.,Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| | - Jang-Yeon Park
- Department of Biomedical Engineering, Sungkyunkwan University, Suwon, Republic of Korea.,Center for Neuroscience Imaging Research, Institute for Basic Science, Suwon, Republic of Korea.,Department of Intelligent Precision Healthcare Convergence, Sungkyunkwan University, Suwon, Republic of Korea
| |
Collapse
|
5
|
Huang J, Chen L, Chan KWY, Cai C, Cai S, Chen Z. Super-resolved water/fat image reconstruction based on single-shot spatiotemporally encoded MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2020; 314:106736. [PMID: 32361511 DOI: 10.1016/j.jmr.2020.106736] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/26/2019] [Revised: 04/11/2020] [Accepted: 04/18/2020] [Indexed: 06/11/2023]
Abstract
Single-shot spatiotemporally encoded (SPEN) MRI has been validated to possess considerable performance in both spatial and temporal resolution. Water/fat separation is essential for MRI applications in which only water signal is needed. In this article, a super-resolved water/fat image reconstruction method (dubbed SWAF) combined prior knowledge was developed based on single-shot SPEN MRI. The point spread function of spatiotemporal encoding under multiple chemical shifts situation was derived and used for constructing an equation for SWAF image reconstruction. By processing the prior chemical shift information with filtering operation, an initial spin density profile of water/fat and a weighting matrix for water/fat residual artifacts suppression were obtained to guide the reconstruction process. A l1 norm minimization problem with regularization was exploited to reconstruct separated water/fat images with high spatial resolution and less residual/aliasing artifacts. Numeric simulation and experiments on water-oil phantom and rat abdomen/neck imaging demonstrated the effectiveness and robustness of this new method. The SWAF method proposed herein would promote the application of SPEN MRI in the cases where water/fat separation is required.
Collapse
Affiliation(s)
- Jianpan Huang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China; Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Lin Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Kannie W Y Chan
- Department of Biomedical Engineering, City University of Hong Kong, Hong Kong, China
| | - Congbo Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| | - Shuhui Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| | - Zhong Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| |
Collapse
|
6
|
Topping GJ, Hundshammer C, Nagel L, Grashei M, Aigner M, Skinner JG, Schulte RF, Schilling F. Acquisition strategies for spatially resolved magnetic resonance detection of hyperpolarized nuclei. MAGMA (NEW YORK, N.Y.) 2020; 33:221-256. [PMID: 31811491 PMCID: PMC7109201 DOI: 10.1007/s10334-019-00807-6] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Revised: 10/08/2019] [Accepted: 11/21/2019] [Indexed: 12/13/2022]
Abstract
Hyperpolarization is an emerging method in magnetic resonance imaging that allows nuclear spin polarization of gases or liquids to be temporarily enhanced by up to five or six orders of magnitude at clinically relevant field strengths and administered at high concentration to a subject at the time of measurement. This transient gain in signal has enabled the non-invasive detection and imaging of gas ventilation and diffusion in the lungs, perfusion in blood vessels and tissues, and metabolic conversion in cells, animals, and patients. The rapid development of this method is based on advances in polarizer technology, the availability of suitable probe isotopes and molecules, improved MRI hardware and pulse sequence development. Acquisition strategies for hyperpolarized nuclei are not yet standardized and are set up individually at most sites depending on the specific requirements of the probe, the object of interest, and the MRI hardware. This review provides a detailed introduction to spatially resolved detection of hyperpolarized nuclei and summarizes novel and previously established acquisition strategies for different key areas of application.
Collapse
Affiliation(s)
- Geoffrey J Topping
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Christian Hundshammer
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Luca Nagel
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Martin Grashei
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Maximilian Aigner
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | - Jason G Skinner
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany
| | | | - Franz Schilling
- Department of Nuclear Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
| |
Collapse
|
7
|
Solomon E, Liberman G, Nissan N, Furman‐Haran E, Sklair‐Levy M, Frydman L. Diffusion‐weighted breast MRI of malignancies with submillimeter resolution and immunity to artifacts by spatiotemporal encoding at 3T. Magn Reson Med 2020; 84:1391-1403. [DOI: 10.1002/mrm.28213] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2019] [Revised: 01/20/2020] [Accepted: 01/22/2020] [Indexed: 11/08/2022]
Affiliation(s)
- Eddy Solomon
- Department of Chemical and Biological Physics Weizmann Institute of Science Rehovot Israel
| | - Gilad Liberman
- Department of Chemical and Biological Physics Weizmann Institute of Science Rehovot Israel
| | - Noam Nissan
- Department of Radiology Sheba‐Medical‐Center Ramat‐Gan Israel
| | - Edna Furman‐Haran
- Life Sciences Core Facilities Weizmann Institute of Science Rehovot Israel
| | - Miri Sklair‐Levy
- Department of Radiology Sheba‐Medical‐Center Ramat‐Gan Israel
- Sackler School of Medicine Tel‐Aviv University Tel‐Aviv Israel
| | - Lucio Frydman
- Department of Chemical and Biological Physics Weizmann Institute of Science Rehovot Israel
| |
Collapse
|
8
|
Bao Q, Ma L, Liberman G, Solomon E, Martinho RP, Frydman L. Dynamic T
2
mapping by multi‐spin‐echo spatiotemporal encoding. Magn Reson Med 2020; 84:895-907. [DOI: 10.1002/mrm.28158] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2019] [Revised: 11/28/2019] [Accepted: 12/11/2019] [Indexed: 12/12/2022]
Affiliation(s)
- Qingjia Bao
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| | - Lingceng Ma
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| | - Gilad Liberman
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| | - Eddy Solomon
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| | - Ricardo P. Martinho
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| | - Lucio Frydman
- Department of Chemical and Biological Physics Weizmann Institute Rehovot Israel
| |
Collapse
|
9
|
Marhabaie S, Bodenhausen G, Pelupessy P. Advances in single-scan time-encoding magnetic resonance imaging. Sci Rep 2018; 8:10891. [PMID: 30022090 PMCID: PMC6052028 DOI: 10.1038/s41598-018-28460-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2018] [Accepted: 06/12/2018] [Indexed: 11/09/2022] Open
Abstract
Time-encoding MRI is a single-scan method that uses traditional k-encoding only in one direction. In the orthogonal “time-encoding” direction, a string of echoes appears in an order that depends on the position of the corresponding spin packets. In one variant of time-encoding, this is achieved by using a series of selective pulses and appropriate gradients in both k-encoding and time-encoding directions. Although time-encoding offers some advantages over traditional single-scan Fourier methods such as echo planar imaging (EPI), the original time-encoding sequence also has some drawbacks that limit its applications. In this work, we show how one can improve several aspects of the original time-encoding sequence. By using an additional gradient pulse one can change the order in which the echoes appear, leading to identical echo times for all echoes, and hence to a uniform signal attenuation due to transverse relaxation and a reduction in average signal attenuation due to diffusion. By rearranging positive and negative gradients one can reduce the switching rate of the gradients. Furthermore, we show how one can implement time-encoding sequences in an interleaved fashion in order to reduce signal attenuation due to transverse relaxation and diffusion, while increasing the spatial resolution.
Collapse
Affiliation(s)
- Sina Marhabaie
- Laboratoire des biomolécules, LBM, Département de chimie, École normale supérieure, PSL University, Sorbonne Université, CNRS, 75005, Paris, France.
| | - Geoffrey Bodenhausen
- Laboratoire des biomolécules, LBM, Département de chimie, École normale supérieure, PSL University, Sorbonne Université, CNRS, 75005, Paris, France
| | - Philippe Pelupessy
- Laboratoire des biomolécules, LBM, Département de chimie, École normale supérieure, PSL University, Sorbonne Université, CNRS, 75005, Paris, France
| |
Collapse
|
10
|
Marhabaie S, Bodenhausen G, Pelupessy P. Susceptibility contrast by echo shifting in spatially encoded single-scan MRI. Phys Chem Chem Phys 2017; 19:14210-14213. [PMID: 28537619 DOI: 10.1039/c7cp01898c] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
To overcome the effects of static field inhomogeneities, single-scan hybrid imaging techniques that use k-space encoding in one direction and spatial encoding in the other have been shown to be superior to traditional imaging techniques based on full k-space encoding. Like traditional imaging methods, hybrid methods can be implemented in different ways that favor different sources of contrast. So far, little attention appears to have been paid to these aspects. By modifying an established hybrid imaging sequence called Rapid Acquisition by Sequential Excitation and Refocusing (RASER) so as to obtain Echo-Shifted RASER sequences, we show that by shifting spin echoes one can tune the contrast due to inhomogeneous T decay.
Collapse
Affiliation(s)
- Sina Marhabaie
- Département de Chimie, École Normale Supérieure, PSL Research University, UPMC Univ Paris 06, CNRS, Laboratoire des Biomolecules (LBM), 24 rue Lhomond, 75005 Paris, France.
| | | | | |
Collapse
|
11
|
Multiple-coil k
-space interpolation enhances resolution in single-shot spatiotemporal MRI. Magn Reson Med 2017; 79:796-805. [DOI: 10.1002/mrm.26731] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/29/2017] [Revised: 04/02/2017] [Accepted: 04/03/2017] [Indexed: 12/17/2022]
|
12
|
Marhabaie S, Bodenhausen G, Pelupessy P. The effects of molecular diffusion in spatially encoded magnetic resonance imaging. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2016; 273:98-104. [PMID: 27821292 DOI: 10.1016/j.jmr.2016.10.010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2016] [Revised: 10/10/2016] [Accepted: 10/14/2016] [Indexed: 06/06/2023]
Abstract
In spatially encoded MRI, the signal is acquired sequentially for different coordinates. In particular for single-scan acquisitions in inhomogeneous fields, spatially encoded methods improve the image quality compared to traditional k-space encoding. Previously, much attention has been paid in order to homogenize T2 losses across the sample. In this work, we investigate the effects of diffusion on the image quality in spatially encoded MRI. We show that losses due to diffusion are often not uniform along the spatially encoded dimension, and how to adapt spatially encoded sequences in order to obtain uniformly diffusion-weighted images.
Collapse
Affiliation(s)
- Sina Marhabaie
- Département de Chimie, École Normale Supérieure, PSL Research University, UPMC Univ Paris 06, CNRS, Laboratoire des Biomolecules (LBM), 24 rue Lhomond, 75005 Paris, France; Sorbonne Universités, UPMC Univ. Paris 06, École Normale Supérieure, CNRS, Laboratoire des Biomolecules (LBM), Paris, France
| | - Geoffrey Bodenhausen
- Département de Chimie, École Normale Supérieure, PSL Research University, UPMC Univ Paris 06, CNRS, Laboratoire des Biomolecules (LBM), 24 rue Lhomond, 75005 Paris, France; Sorbonne Universités, UPMC Univ. Paris 06, École Normale Supérieure, CNRS, Laboratoire des Biomolecules (LBM), Paris, France; Institut des Sciences et Ingéniérie Chimiques, Ecole Polytechnique Fédérale de Lausanne, 1015 Lausanne, Switzerland
| | - Philippe Pelupessy
- Département de Chimie, École Normale Supérieure, PSL Research University, UPMC Univ Paris 06, CNRS, Laboratoire des Biomolecules (LBM), 24 rue Lhomond, 75005 Paris, France; Sorbonne Universités, UPMC Univ. Paris 06, École Normale Supérieure, CNRS, Laboratoire des Biomolecules (LBM), Paris, France.
| |
Collapse
|
13
|
Chen L, Huang J, Zhang T, Li J, Cai C, Cai S. Variable density sampling and non-Cartesian super-resolved reconstruction for spatiotemporally encoded single-shot MRI. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2016; 272:1-9. [PMID: 27591366 DOI: 10.1016/j.jmr.2016.08.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2016] [Revised: 08/14/2016] [Accepted: 08/26/2016] [Indexed: 06/06/2023]
Abstract
Spatiotemporally encoded (SPEN) single-shot MRI is an emerging ultrafast technique, which is capable of spatially selective acquisition and reduced field-of-view imaging. Compared to uniform sampling, variable density sampling has great potential in reducing aliasing artifacts and improving sampling efficiency. In this study, variable density spiral trajectory and non-Cartesian super-resolved (SR) reconstruction method are developed for SPEN MRI. The gradient waveforms design of spiral trajectory is mathematically described as an optimization problem subjected to the limitations of hardware. Non-Cartesian SR reconstruction with specific gridding method is developed to retrieve a resolution enhanced image from raw SPEN data. The robustness and efficiency of the proposed methods are demonstrated by numerical simulation and various experiments. The results indicate that variable density SPEN MRI can provide better spatial resolution and fewer aliasing artifacts compared to Cartesian counterpart. The proposed methods will facilitate the development of variable density SPEN MRI.
Collapse
Affiliation(s)
- Lin Chen
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China; Russell H. Morgan Department of Radiology and Radiological Science, The Johns Hopkins University School of Medicine, Baltimore, MD 21205, United States.
| | - Jianpan Huang
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China.
| | - Ting Zhang
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China.
| | - Jing Li
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China.
| | - Congbo Cai
- Department of Communication Engineering, Xiamen University, Xiamen 361005, China.
| | - Shuhui Cai
- Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Collaborative Innovation Center for Optoelectronic Semiconductors and Efficient Devices, Department of Electronic Science, Xiamen University, Xiamen 361005, China.
| |
Collapse
|
14
|
Zhang T, Chen L, Huang J, Li J, Cai S, Cai C, Chen Z. Ultrafast multi-slice spatiotemporally encoded MRI with slice-selective dimension segmented. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2016; 269:138-145. [PMID: 27301072 DOI: 10.1016/j.jmr.2016.06.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Revised: 05/30/2016] [Accepted: 06/03/2016] [Indexed: 06/06/2023]
Abstract
As a recently emerging method, spatiotemporally encoded (SPEN) magnetic resonance imaging (MRI) has a high robustness to field inhomogeneity and chemical shift effect. It has been broadened from single-slice scanning to multi-slice scanning. In this paper, a novel multi-slice SPEN MRI method was proposed. In this method, the slice-selective dimension was segmented to lower the specific absorption rate (SAR) and improve the image quality. This segmented method, dubbed SeSPEN method, was theoretically analyzed and demonstrated with phantom, lemon and in vivo rat brain experiments. The experimental results were compared with the results obtained from the spin-echo EPI, spin-echo SPEN method and multi-slice global SPEN method proposed by Frydman and coauthors (abbr. GlSPEN method). All the SPEN images were super-resolved reconstructed using deconvolution method. The results indicate that the SeSPEN method retains the advantage of SPEN MRI with respect to resistance to field inhomogeneity and can provide better signal-to-noise ratio than multi-slice GlSPEN MRI technique. The SeSPEN method has comparable SAR to the GlSPEN method while the T1 signal attenuation effect is alleviated. The proposed method will facilitate the multi-slice SPEN MRI to scan more slices within one scan with better image quality.
Collapse
Affiliation(s)
- Ting Zhang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| | - Lin Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| | - Jianpan Huang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| | - Jing Li
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| | - Shuhui Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| | - Congbo Cai
- Department of Communication Engineering, Xiamen University, Xiamen, China.
| | - Zhong Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| |
Collapse
|
15
|
Solomon E, Liberman G, Nissan N, Frydman L. Robust diffusion tensor imaging by spatiotemporal encoding: Principles and in vivo demonstrations. Magn Reson Med 2016; 77:1124-1133. [PMID: 26968710 DOI: 10.1002/mrm.26197] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2015] [Revised: 02/11/2016] [Accepted: 02/11/2016] [Indexed: 12/19/2022]
Abstract
PURPOSE Evaluate the usefulness of single-shot and of interleaved spatiotemporally encoded (SPEN) methods to perform diffusion tensor imaging (DTI) under various preclinical and clinical settings. METHODS A formalism for analyzing SPEN DTI data is presented, tailored to account for the spatially dependent b-matrix weightings introduced by the sequence's use of swept pulses acting while in the presence of field gradients. Using these b-matrix calculations, SPEN's ability to deliver DTI measurements was tested on phantoms as well as ex vivo and in vivo. In the latter case, DTI involved scans on mice brains and on human lactating breasts. RESULTS For both ex vivo and in vivo investigations, SPEN data proved less sensitive to distortions arising from Bo field inhomogeneities and from eddy currents, than conventional single-shot alternatives. Further resolution enhancement could be achieved using referenceless methods for interleaved SPEN data acquisitions. CONCLUSION The robustness of SPEN-based sequences vis-à-vis field instabilities and heterogeneities, enables the implementation of DTI experiments with good sensitivity and resolution even in challenging environments in both preclinical and clinical settings. Magn Reson Med 77:1124-1133, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Eddy Solomon
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Gilad Liberman
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Noam Nissan
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel.,Department of Biological Regulation, Weizmann Institute of Science, Rehovot, Israel
| | - Lucio Frydman
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| |
Collapse
|
16
|
Chen L, Li J, Zhang M, Cai S, Zhang T, Cai C, Chen Z. Super-resolved enhancing and edge deghosting (SEED) for spatiotemporally encoded single-shot MRI. Med Image Anal 2015; 23:1-14. [DOI: 10.1016/j.media.2015.03.004] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 02/12/2015] [Accepted: 03/10/2015] [Indexed: 10/23/2022]
|
17
|
Li J, Zhang M, Chen L, Cai C, Sun H, Cai S. Reduced field-of-view imaging for single-shot MRI with an amplitude-modulated chirp pulse excitation and Fourier transform reconstruction. Magn Reson Imaging 2015; 33:503-15. [PMID: 25721996 DOI: 10.1016/j.mri.2015.02.019] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2014] [Revised: 01/21/2015] [Accepted: 02/16/2015] [Indexed: 11/18/2022]
Abstract
PURPOSE We employ an amplitude-modulated chirp pulse to selectively excite spins in one or more regions of interest (ROIs) to realize reduced field-of-view (rFOV) imaging based on single-shot spatiotemporally encoded (SPEN) sequence and Fourier transform reconstruction. MATERIALS AND METHODS The proposed rFOV imaging method was theoretically analyzed and illustrated with numerical simulation and tested with phantom experiments and in vivo rat experiments. In addition, point spread function was applied to demonstrate the feasibility of the proposed method. To evaluate the proposed method, the rFOV results were compared with those obtained using the EPI method with orthogonal RF excitation. RESULTS The simulation and experimental results show that the proposed method can image one or two separated ROIs along the SPEN dimension in a single shot with higher spatial resolution, less sensitive to field inhomogeneity, and practically no aliasing artifacts. In addition, the proposed method may produce rFOV images with comparable signal-to-noise ratio to the rFOV EPI images. CONCLUSION The proposed method is promising for the applications under severe susceptibility heterogeneities and for imaging separate ROIs simultaneously.
Collapse
Affiliation(s)
- Jing Li
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Miao Zhang
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Lin Chen
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Congbo Cai
- Department of Communication Engineering, Xiamen University, Xiamen, China.
| | - Huijun Sun
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China
| | - Shuhui Cai
- Department of Electronic Science, Fujian Provincial Key Laboratory of Plasma and Magnetic Resonance, Xiamen University, Xiamen, China.
| |
Collapse
|
18
|
Fernández-Valle ME, Martínez-Álvarez R, Molero-Vílchez D, Pardo ZD, Sáez-Barajas E, Herrera A. 2D Ultrafast HMBC 1H,31P: Obtaining Mechanistic Details on the Michaelis–Arbuzov Reaction. J Org Chem 2014; 80:799-805. [DOI: 10.1021/jo502253p] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
| | - Roberto Martínez-Álvarez
- Departamento
de Química Orgánica I, Facultad de Químicas, Universidad Complutense, 28040 Madrid, Spain
| | | | - Zulay D. Pardo
- Departamento
de Química Orgánica I, Facultad de Químicas, Universidad Complutense, 28040 Madrid, Spain
| | - Elena Sáez-Barajas
- CAI
de RMN y RSE, Facultad de Químicas, Universidad Complutense, 28040 Madrid, Spain
| | - Antonio Herrera
- Departamento
de Química Orgánica I, Facultad de Químicas, Universidad Complutense, 28040 Madrid, Spain
- CAI
de RMN y RSE, Facultad de Químicas, Universidad Complutense, 28040 Madrid, Spain
| |
Collapse
|
19
|
Solomon E, Nissan N, Furman-Haran E, Seginer A, Shapiro-Feinberg M, Degani H, Frydman L. Overcoming limitations in diffusion-weighted MRI of breast by spatio-temporal encoding. Magn Reson Med 2014; 73:2163-73. [PMID: 25045867 DOI: 10.1002/mrm.25344] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2014] [Revised: 05/25/2014] [Accepted: 06/11/2014] [Indexed: 01/20/2023]
Abstract
PURPOSE Evaluating the usefulness of diffusion-weighted spatio-temporal encoding (SPEN) methods to provide quantitative apparent diffusion coefficient (ADC)-based characterizations of healthy and malignant human breast tissues, in comparison with results obtained using techniques based on spin-echo echo planar imaging (SE-EPI). METHODS Twelve healthy volunteers and six breast cancer patients were scanned at 3T using scanner-supplied diffusion-weighted imaging EPI sequences, as well as two fully refocused SPEN variants programmed in-house. Suitable codes were written to process the data, including calculations of the actual b-values and retrieval of the ADC maps. RESULTS Systematically better images were afforded by the SPEN scans, with negligible geometrical distortions and markedly weaker ghosting artifacts arising from either fat tissues or from strongly emitting areas such as cysts. SPEN-derived images provided improved characterizations of the fibroglandular tissues and of the lesions' contours. When translated into the calculation of the ADC maps, there were no significant differences between the mean ADCs derived from SPEN and SE-EPI: if reliable images were available, both techniques showed that ADCs decreased by nearly two-fold in the malignant lesion areas. CONCLUSION SPEN-based sequences yielded diffusion-weighted breast images with minimal artifacts and distortions, enabling the calculation of improved ADC maps and the identification of decreased ADCs in malignant regions.
Collapse
Affiliation(s)
- Eddy Solomon
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Noam Nissan
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel.,Department of Biological Regulation, Weizmann Institute of Science, Rehovot, Israel
| | - Edna Furman-Haran
- Unit of Biological Services, Weizmann Institute of Science, Rehovot, Israel
| | - Amir Seginer
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | | | - Hadassa Degani
- Department of Biological Regulation, Weizmann Institute of Science, Rehovot, Israel
| | - Lucio Frydman
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| |
Collapse
|
20
|
Leftin A, Rosenberg JT, Solomon E, Calixto Bejarano F, Grant SC, Frydman L. Ultrafast in vivo diffusion imaging of stroke at 21.1 T by spatiotemporal encoding. Magn Reson Med 2014; 73:1483-9. [PMID: 24845125 DOI: 10.1002/mrm.25271] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2014] [Revised: 04/03/2014] [Accepted: 04/08/2014] [Indexed: 11/06/2022]
Abstract
PURPOSE This study quantifies in vivo ischemic stroke brain injuries in rats using ultrahigh-field single-scan MRI methods to assess variations in apparent diffusion coefficients (ADCs). METHODS Magnitude and diffusion-weighted spatiotemporally encoded imaging sequences were implemented on a 21.1 T imaging system, and compared with spin-echo and echo-planar imaging diffusion-weighted imaging strategies. ADC maps were calculated and used to evaluate the sequences according to the statistical comparisons of the ipsilateral and contralateral ADC measurements at 24, 48, and 72 h poststroke. RESULTS Susceptibility artifacts resulting from normative anatomy and pathological stroke conditions were particularly intense at 21.1 T. These artifacts strongly distorted single-shot diffusion-weighted echo-planar imaging experiments, but were reduced in four-segment interleaved echo-planar imaging acquisitions. By contrast, nonsegmented diffusion-weighted spatiotemporally encoded images were largely immune to field-dependent artifacts. Effects of stroke were apparent in both magnitude images and ADC maps of all sequences. When stroke recovery was followed by ADC variations, spatiotemporally encoded, echo-planar imaging, and spin-echo acquisitions revealed statistically significant increase in ADCs. CONCLUSIONS Consideration of experiment duration, image quality, and mapped ADC values provided by spatiotemporally encoded demonstrates that this single-shot acquisition is a method of choice for high-throughput, ultrahigh-field in vivo stroke quantification.
Collapse
Affiliation(s)
- Avigdor Leftin
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | | | | | | | | | | |
Collapse
|
21
|
Schmidt R, Laustsen C, Dumez JN, Kettunen MI, Serrao EM, Marco-Rius I, Brindle KM, Ardenkjaer-Larsen JH, Frydman L. In vivo single-shot 13C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2014; 240:8-15. [PMID: 24486720 PMCID: PMC5040493 DOI: 10.1016/j.jmr.2013.12.013] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/12/2013] [Revised: 11/17/2013] [Accepted: 12/18/2013] [Indexed: 05/08/2023]
Abstract
Hyperpolarized metabolic imaging is a growing field that has provided a new tool for analyzing metabolism, particularly in cancer. Given the short life times of the hyperpolarized signal, fast and effective spectroscopic imaging methods compatible with dynamic metabolic characterizations are necessary. Several approaches have been customized for hyperpolarized (13)C MRI, including CSI with a center-out k-space encoding, EPSI, and spectrally selective pulses in combination with spiral EPI acquisitions. Recent studies have described the potential of single-shot alternatives based on spatiotemporal encoding (SPEN) principles, to derive chemical-shift images within a sub-second period. By contrast to EPSI, SPEN does not require oscillating acquisition gradients to deliver chemical-shift information: its signal encodes both spatial as well as chemical shift information, at no extra cost in experimental complexity. SPEN MRI sequences with slice-selection and arbitrary excitation pulses can also be devised, endowing SPEN with the potential to deliver single-shot multi-slice chemical shift images, with a temporal resolution required for hyperpolarized dynamic metabolic imaging. The present work demonstrates this with initial in vivo results obtained from SPEN-based imaging of pyruvate and its metabolic products, after injection of hyperpolarized [1-(13)C]pyruvate. Multi-slice chemical-shift images of healthy rats were obtained at 4.7T in the region of the kidney, and 4D (2D spatial, 1D spectral, 1D temporal) data sets were obtained at 7T from a murine lymphoma tumor model.
Collapse
Affiliation(s)
- Rita Schmidt
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Christoffer Laustsen
- MR Research Centre, Aarhus University, Denmark; Danish Research Centre for Magnetic Resonance, Hvidovre Hospital, Denmark
| | - Jean-Nicolas Dumez
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel
| | - Mikko I Kettunen
- Department of Biochemistry, University of Cambridge, Cambridge, United Kingdom; Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Cambridge, United Kingdom
| | - Eva M Serrao
- Department of Biochemistry, University of Cambridge, Cambridge, United Kingdom; Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Cambridge, United Kingdom
| | - Irene Marco-Rius
- Department of Biochemistry, University of Cambridge, Cambridge, United Kingdom; Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Cambridge, United Kingdom
| | - Kevin M Brindle
- Department of Biochemistry, University of Cambridge, Cambridge, United Kingdom; Cancer Research UK Cambridge Institute, Li Ka Shing Centre, Cambridge, United Kingdom
| | | | - Lucio Frydman
- Department of Chemical Physics, Weizmann Institute of Science, Rehovot, Israel.
| |
Collapse
|