1
|
Navarro P, Olmo A, Giner M, Rodríguez-Albelo M, Rodríguez Á, Torres Y. Electrical Impedance of Surface Modified Porous Titanium Implants with Femtosecond Laser. MATERIALS 2022; 15:ma15020461. [PMID: 35057181 PMCID: PMC8779557 DOI: 10.3390/ma15020461] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/10/2021] [Revised: 12/31/2021] [Accepted: 01/04/2022] [Indexed: 01/25/2023]
Abstract
The chemical composition and surface topography of titanium implants are essential to improve implant osseointegration. The present work studies a non-invasive alternative of electrical impedance spectroscopy for the characterization of the macroporosity inherent to the manufacturing process and the effect of the surface treatment with femtosecond laser of titanium discs. Osteoblasts cell culture growths on the titanium surfaces of the laser-treated discs were also studied with this method. The measurements obtained showed that the femtosecond laser treatment of the samples and cell culture produced a significant increase (around 50%) in the absolute value of the electrical impedance module, which could be characterized in a wide range of frequencies (being more relevant at 500 MHz). Results have revealed the potential of this measurement technique, in terms of advantages, in comparison to tiresome and expensive techniques, allowing semi-quantitatively relating impedance measurements to porosity content, as well as detecting the effect of surface modification, generated by laser treatment and cell culture.
Collapse
Affiliation(s)
- Paula Navarro
- Departamento de Tecnología Electrónica, Escuela Técnica Superior de Ingeniería Informática, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla, Spain;
- Departamento de Ingeniería y Ciencia de los Materiales y del Transporte, Escuela Politécnica Superior, Calle Virgen de África 7, 41011 Seville, Spain; (M.R.-A.); (Y.T.)
| | - Alberto Olmo
- Departamento de Tecnología Electrónica, Escuela Técnica Superior de Ingeniería Informática, Universidad de Sevilla, Av. Reina Mercedes s/n, 41012 Sevilla, Spain;
- Instituto de Microelectrónica de Sevilla, IMSE-CNM (CSIC, Universidad de Sevilla), Av. Américo Vespucio s/n, 41092 Sevilla, Spain
- Correspondence: ; Tel.: +34-954556835
| | - Mercè Giner
- Departamento de Citología e Histología Normal y Patológica, Universidad de Sevilla, Av. Doctor Fedriani s/n, 41009 Sevilla, Spain;
| | - Marleny Rodríguez-Albelo
- Departamento de Ingeniería y Ciencia de los Materiales y del Transporte, Escuela Politécnica Superior, Calle Virgen de África 7, 41011 Seville, Spain; (M.R.-A.); (Y.T.)
| | - Ángel Rodríguez
- Escuela Politécnica Superior, Universidad da Coruña, Calle Mendizábal s/n, 15403 Ferrol, Spain;
| | - Yadir Torres
- Departamento de Ingeniería y Ciencia de los Materiales y del Transporte, Escuela Politécnica Superior, Calle Virgen de África 7, 41011 Seville, Spain; (M.R.-A.); (Y.T.)
| |
Collapse
|
2
|
Lv Y, Sun S, Zhang X, Lu X, Dong Z. Construction of multi-layered Zn-modified TiO 2 coating by ultrasound-auxiliary micro-arc oxidation: Microstructure and biological property. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 131:112487. [PMID: 34857273 DOI: 10.1016/j.msec.2021.112487] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 09/24/2021] [Accepted: 10/09/2021] [Indexed: 12/13/2022]
Abstract
Surfaces with desirable cytocompatibility and bactericidal ability are favoured for orthopaedic implants to stimulate osteogenic activity and to prevent implant-associated infection. In this work, we creatively introduce ultrasonic vibration (UV) to micro-arc oxidation (MAO) process and explore its influence on the microstructure, corrosion property and biological responses of Zn-modified TiO2 coating. With the introduction of UV, a uniform surface layer with homogeneously-distributed clusters could be produced as the outer layer, which possesses a fusion band with the underlying TiO2. The microstructural modification associated with UV results in the enhanced corrosion resistance, increased adhesive strength and improved biological performances of the resultant coating relative to that with the absence of UV. Hence, the ultrasonic auxiliary micro-arc oxidation (UMAO) is regarded as a promising surface modification method to produce Ti-based orthopaedic implants of high quality.
Collapse
Affiliation(s)
- You Lv
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; Hubei Engineering Research Centre for Biomaterials and Medical Protective Materials, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Siqin Sun
- Wuhan Third Hospital, Tongren Hospital of Wuhan University, 216 Guanshan Road, Hongshan District, 430060, PR China
| | - Xinxin Zhang
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China; Hubei Engineering Research Centre for Biomaterials and Medical Protective Materials, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Xueqin Lu
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Zehua Dong
- Key Laboratory of Material Chemistry for Energy Conversion and Storage, Ministry of Education, Hubei Key Laboratory of Material Chemistry and Service Failure, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
3
|
Susceptibility to Pitting Corrosion of Ti-CP2, Ti-6Al-2Sn-4Zr-2Mo, and Ti-6Al-4V Alloys for Aeronautical Applications. METALS 2021. [DOI: 10.3390/met11071002] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Titanium alloys are used in different industries like biomedical, aerospace, aeronautic, chemical, and naval. Those industries have high requirements with few damage tolerances. Therefore, they are necessary to use materials that present fatigue, mechanical, and corrosion resistance. Although Ti-alloys are material with high performance, they are exposed to corrosion in marine and industrial environments. This research shows the corrosion behavior of three titanium alloys, specifically Ti CP2, Ti-6Al-2Sn-4Zr-2Mo, and Ti-6Al-4V. Alloys were exposed on two electrolytes to a 3.5 wt % H2SO4 and NaCl solutions at room temperature using cyclic potentiodynamic polarization (CPP) and electrochemical noise (EN) according to ASTM G61 and ASTM G199 standards. CPP technique was employed to obtain electrochemical parameters as the passivation range (PR), corrosion type, passive layer persistence, corrosion potential (Ecorr), and corrosion rate. EN was analyzed by power spectral density (PSD) in voltage. Results obtained revealed pseudopassivation in CPP and PSD exposed on NaCl for Ti-6Al-2Sn-4Zr-2Mo, indicating instability and corrosion rate lower. However, Ti-6Al-4V presented the highest corrosion rate in both electrolytes. Ti-6Al-2Sn-4Zr-2Mo revealed pseudopassivation in CPP and PSD in NaCl, indicating a passive layer unstable. However, the corrosion rate was lower in both solutions.
Collapse
|
4
|
Dziaduszewska M, Zieliński A. Structural and Material Determinants Influencing the Behavior of Porous Ti and Its Alloys Made by Additive Manufacturing Techniques for Biomedical Applications. MATERIALS (BASEL, SWITZERLAND) 2021; 14:712. [PMID: 33546358 PMCID: PMC7913507 DOI: 10.3390/ma14040712] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 01/24/2021] [Accepted: 01/27/2021] [Indexed: 11/20/2022]
Abstract
One of the biggest challenges in tissue engineering is the manufacturing of porous structures that are customized in size and shape and that mimic natural bone structure. Additive manufacturing is known as a sufficient method to produce 3D porous structures used as bone substitutes in large segmental bone defects. The literature indicates that the mechanical and biological properties of scaffolds highly depend on geometrical features of structure (pore size, pore shape, porosity), surface morphology, and chemistry. The objective of this review is to present the latest advances and trends in the development of titanium scaffolds concerning the relationships between applied materials, manufacturing methods, and interior architecture determined by porosity, pore shape, and size, and the mechanical, biological, chemical, and physical properties. Such a review is assumed to show the real achievements and, on the other side, shortages in so far research.
Collapse
Affiliation(s)
- Magda Dziaduszewska
- Biomaterials Technology Division, Institute of Machines Technology and Materials, Faculty of Mechanical Engineering and Ship Building, Gdańsk University of Technology, 80-233 Gdańsk, Poland;
| | | |
Collapse
|
5
|
Electrochemical Noise Analysis of the Corrosion of Titanium Alloys in NaCl and H2SO4 Solutions. METALS 2021. [DOI: 10.3390/met11010105] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
Titanium alloys have been used in aerospace, aeronautic, automotive, biomedical, structural, and other applications because titanium alloys have less density than materials like steel and support higher stress than Al-alloys. However, components made of titanium alloys are exposed to corrosive environments, the most common being industrial and marine atmospheres. This research shows the corrosion behavior of three titanium alloys, specifically Ti-CP2, Ti-6Al-2Sn-4Zr-2Mo, and Ti-6Al-4V with α, near α, and α + β alloys phases. Alloys were exposed in two electrolytes to a 3.5 wt. % H2SO4 and NaCl solution at room temperature, and their electrochemical behavior was studied by electrochemical noise technique (EN) according to ASTM ASTM-G199 standard. EN signal was filtered by three different methods, and the polynomial method was employed to obtain Rn, kurtosis, skew, and the potential spectral density analysis (PSD). The wavelets method was used, from which energy dispersion plots were obtained. The last method was Hilbert–Huang Transform (HHT), where Hilbert Spectra were analyzed. Results indicated that Rn compared with PSD showed that Ti-6Al-2Sn-4Zr-2Mo presented less dissolution in both electrolytes. Statistical methods showed that the passive layer created on Ti alloys’ surfaces is unstable; this condition is notable for Ti-6Al-2Sn-4Zr-2Mo in NaCl solution.
Collapse
|
6
|
Olmo A, Hernández M, Chicardi E, Torres Y. Characterization and Monitoring of Titanium Bone Implants with Impedance Spectroscopy. SENSORS 2020; 20:s20164358. [PMID: 32764276 PMCID: PMC7472105 DOI: 10.3390/s20164358] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 07/27/2020] [Accepted: 08/03/2020] [Indexed: 12/30/2022]
Abstract
Porous titanium is a metallic biomaterial with good properties for the clinical repair of cortical bone tissue, although the presence of pores can compromise its mechanical behavior and clinical use. It is therefore necessary to characterize the implant pore size and distribution in a suitable way. In this work, we explore the new use of electrical impedance spectroscopy for the characterization and monitoring of titanium bone implants. Electrical impedance spectroscopy has been used as a non-invasive route to characterize the volumetric porosity percentage (30%, 40%, 50% and 60%) and the range of pore size (100–200 and 355–500 mm) of porous titanium samples obtained with the space-holder technique. Impedance spectroscopy is proved to be an appropriate technique to characterize the level of porosity of the titanium samples and pore size, in an affordable and non-invasive way. The technique could also be used in smart implants to detect changes in the service life of the material, such as the appearance of fractures, the adhesion of osteoblasts and bacteria, or the formation of bone tissue.
Collapse
Affiliation(s)
- Alberto Olmo
- Instituto de Microelectrónica de Sevilla, IMSE-CNM (CSIC, Universidad de Sevilla), Av. Américo Vespucio, sn, 41092 Sevilla, Spain;
- Escuela Técnica Superior de Ingeniería Informática, Departamento de Tecnología Electrónica, Universidad de Sevilla, Av. Reina Mercedes sn, 41012 Sevilla, Spain
- Correspondence: ; Tel.: +34-09-5455-4325
| | - Miguel Hernández
- Instituto de Microelectrónica de Sevilla, IMSE-CNM (CSIC, Universidad de Sevilla), Av. Américo Vespucio, sn, 41092 Sevilla, Spain;
- Escuela Técnica Superior de Ingeniería Informática, Departamento de Tecnología Electrónica, Universidad de Sevilla, Av. Reina Mercedes sn, 41012 Sevilla, Spain
| | - Ernesto Chicardi
- Departamento de Ingeniería y Ciencia de los Materiales y del Transporte, Escuela Superior de Ingenieros, Universidad de Sevilla, 41092 Sevilla, Spain;
| | - Yadir Torres
- Departamento de Ingeniería y Ciencia de los Materiales y del Transporte, Escuela Politécnica Superior, Calle Virgen de África, 7, 41011 Sevilla, Spain;
| |
Collapse
|
7
|
Radovanović MB, Tasić Ž, Simonović AT, Petrović Mihajlović MB, Antonijević MM. Corrosion Behavior of Titanium in Simulated Body Solutions with the Addition of Biomolecules. ACS OMEGA 2020; 5:12768-12776. [PMID: 32548461 PMCID: PMC7288364 DOI: 10.1021/acsomega.0c00390] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Accepted: 04/13/2020] [Indexed: 06/11/2023]
Abstract
Titanium is one of the most used biomaterials for different applications. The aim of this study is to investigate the influence of adenine, thymine, and l-histidine as important biomolecules in the human body on the corrosion behavior of titanium in simulated body solutions. Open circuit measurements, potentiodynamic measurements, electrochemical impedance spectroscopy measurements, and quantum chemical calculations were employed during the investigation. All electrochemical methods used revealed that the investigated biomolecules provide better corrosion resistance to titanium in artificial body solutions. The increase in corrosion resistance is a result of the formation of a stable protective film on the metal surface. Also, quantum chemical calculations are in compliance with electrochemical test results and indicate that adenine, thymine, and l-histidine may act as corrosion inhibitors in the investigated solutions.
Collapse
|
8
|
Guerra C, Sancy M, Walczak M, Martínez C, Ringuedé A, Cassir M, Han J, Ogle K, de Melo HG, Salinas V, Aguilar C. Effect of added porosity on a novel porous Ti-Nb-Ta-Fe-Mn alloy exposed to simulated body fluid. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 111:110758. [PMID: 32279776 DOI: 10.1016/j.msec.2020.110758] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/17/2019] [Revised: 01/06/2020] [Accepted: 02/16/2020] [Indexed: 11/18/2022]
Affiliation(s)
- Carolina Guerra
- Departamento de Ingeniería Mecánica y Metalúrgica, Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, Chile.
| | - Mamié Sancy
- Departamento de Ingeniería Mecánica y Metalúrgica, Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, Chile; Escuela de Construcción Civil, Facultad de Ingeniería, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, Chile; Centro de Investigación en Nanotecnología y Materiales Avanzados "CIEN-UC", Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, Chile.
| | - Magdalena Walczak
- Departamento de Ingeniería Mecánica y Metalúrgica, Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, Chile; Centro de Investigación en Nanotecnología y Materiales Avanzados "CIEN-UC", Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, Chile
| | - Carola Martínez
- Escuela de Construcción Civil, Facultad de Ingeniería, Pontificia Universidad Católica de Chile, Av. Vicuña Mackenna 4860, Macul, Santiago, Chile; Departamento de Ingeniería Metalúrgica y de Materiales, Universidad Técnica Federico Santa María, Av. España 1680, Valparaíso, Chile
| | - Armelle Ringuedé
- Chimie ParisTech, PSL University, CNRS, Institut de Recherche de Cheimie de Paris, 75005 Paris, France
| | - Michel Cassir
- Chimie ParisTech, PSL University, CNRS, Institut de Recherche de Cheimie de Paris, 75005 Paris, France
| | - Junsoo Han
- Chimie ParisTech, PSL University, CNRS, Institut de Recherche de Cheimie de Paris, 75005 Paris, France
| | - Kevin Ogle
- Chimie ParisTech, PSL University, CNRS, Institut de Recherche de Cheimie de Paris, 75005 Paris, France
| | - Hercílio Gomes de Melo
- Departamento de Eng. Metalúrgica e de Materiais, Escola Politécnica da Universidade de São Paulo, Av. Prof. Mello Moraes, 2463, São Paulo, Brazil
| | - Vicente Salinas
- Instituto de Ciencias Químicas Aplicadas (ICQA), Facultad de Ingeniería, Universidad Autónoma de Chile, Av. Pedro de Valdivia 425, Santiago, Chile
| | - Claudio Aguilar
- Departamento de Ingeniería Metalúrgica y de Materiales, Universidad Técnica Federico Santa María, Av. España 1680, Valparaíso, Chile
| |
Collapse
|
9
|
Xu LN, Yu XY, Chen WQ, Zhang SM, Qiu J. Biocorrosion of pure and SLA titanium surfaces in the presence of Porphyromonas gingivalis and its effects on osteoblast behavior. RSC Adv 2020; 10:8198-8206. [PMID: 35497867 PMCID: PMC9049922 DOI: 10.1039/d0ra00154f] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2020] [Accepted: 02/20/2020] [Indexed: 01/25/2023] Open
Abstract
Objective: The study aims to investigate the biocorrosion behavior of Porphyromonas gingivalis on pure and SLA titanium surfaces and its effects on surface characteristics and osteoblast behavior. Methods: Pure and SLA titanium specimens were immersed in culture medium with P. gingivalis and incubated for 7 days. P. gingivalis colonization on the pure and SLA titanium surfaces was observed by scanning electron microscopy (SEM). The pure and SLA titanium surface characteristics were analyzed via X-ray photoelectron spectroscopy (XPS), surface roughness and surface wettability. The corrosion behaviors of pure and SLA titanium specimens were evaluated by electrochemical corrosion test. The osteoblast behavior of MC3T3-E1 cells on the pure and SLA titanium surfaces after P. gingivalis colonization was investigated by cell adhesion and western blot assays. Results: P. gingivalis colonized on the pure and SLA titanium surfaces was observed by SEM. The XPS analysis demonstrated reductions in the relative levels of titanium and oxygen and obvious reductions of dominant titanium dioxide (TiO2) on both titanium surfaces after immersing the metal in P. gingivalis culture. In addition, their roughness and wettability were changed. Correspondingly, the electrochemical corrosion test results revealed significant decreases in the corrosion resistance and increases in the corrosion rate of the pure and SLA titanium specimens after immersion in P. gingivalis culture. The results of the in vitro study showed that the pre-corroded pure and SLA titanium surfaces by P. gingivalis exhibited lower osteocompatibility and down-regulated the adhesion, spreading and osteogenic differentiation abilities of MC3T3-E1 cells. Conclusions: P. gingivalis was able to colonize on the pure and SLA titanium surfaces and weaken their surface properties, especially a decrease in the protective TiO2 film, which induced the biocorrosion and further negatively affected the osteoblast behavior. The study demonstrated that P. gingivalis could colonize on pure and SLA titanium surfaces and weaken their surface properties, especially the protective TiO2 film, which induced the biocorrosion and further negatively affected osteoblast behavior.![]()
Collapse
Affiliation(s)
- Li-na Xu
- Department of Oral Implantology
- Affiliated Hospital of Stomatology
- Nanjing Medical University
- Nanjing
- PR China
| | - Xiao-yu Yu
- Department of Oral Implantology
- Affiliated Hospital of Stomatology
- Nanjing Medical University
- Nanjing
- PR China
| | - Wan-qing Chen
- Department of Oral Implantology
- Affiliated Hospital of Stomatology
- Nanjing Medical University
- Nanjing
- PR China
| | - Song-mei Zhang
- Department of General Dentistry
- Eastman Institute for Oral Health
- University of Rochester
- Rochester
- USA
| | - Jing Qiu
- Department of Oral Implantology
- Affiliated Hospital of Stomatology
- Nanjing Medical University
- Nanjing
- PR China
| |
Collapse
|
10
|
Loh XJ, Kai D. Special issue: Biomedical applications editorial. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 70:933-934. [PMID: 27772723 DOI: 10.1016/j.msec.2016.08.082] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Xian Jun Loh
- Institute of Materials Research and Engineering (IMRE), 2 Fusionopolis Way, Innovis, #08-03, 138634 Singapore.
| | - Dan Kai
- Institute of Materials Research and Engineering (IMRE), 2 Fusionopolis Way, Innovis, #08-03, 138634 Singapore
| |
Collapse
|