1
|
Dini C, Yamashita KM, Sacramento CM, Borges MHR, Takeda TTS, Silva JPDS, Nagay BE, Costa RC, da Cruz NC, Rangel EC, Ruiz KGS, Barão VAR. Tailoring magnesium-doped coatings for improving surface and biological properties of titanium-based dental implants. Colloids Surf B Biointerfaces 2025; 246:114382. [PMID: 39591849 DOI: 10.1016/j.colsurfb.2024.114382] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2024] [Revised: 10/30/2024] [Accepted: 11/13/2024] [Indexed: 11/28/2024]
Abstract
Physicochemical modifications of biomaterials have been proposed to overcome bone integration impairment and microbial infections. The magnesium (Mg) incorporation on dental implant surfaces has shown positive results in bone-to-implant contact and in the reduction of microbial colonization. Here, we explored the potential of using different Mg precursors to synthesize coatings via plasma electrolytic oxidation (PEO) on commercially pure titanium (cpTi), aiming to optimize the surface and biological properties. For this, we investigated Mg acetate and Mg nitrate precursors in different concentrations (0.04 M and 0.12 M), using calcium (Ca) and phosphorus (P) as the base electrolyte for all groups. Coatings with only the CaP base electrolyte were used as the control group. The surfaces were characterized by confocal laser scanning microscopy, scanning electron microscopy, film thickness measurement, profilometry, wettability, X-ray diffraction, energy dispersive spectroscopy, X-ray photoelectron spectroscopy, electrochemical behavior, and ion release. For biological analyses, the adhesion (2 h) of Streptococcus sanguinis was evaluated, as well as MC3T3-E1 osteoblastic cells proliferation at 1 and 3 days, and mineralization of calcium phosphates after 28 days. PEO treatment using different Mg precursors promoted physicochemical modifications of cpTi. The experimental groups MgN 0.04 and MgN 0.12 exhibited higher surface roughness and wettability compared to the other surfaces. Regardless of the Mg precursor, the higher the ion concentration in the electrolyte solution, the higher the Mg atomic concentration on the surfaces. Concerning the electrochemical behavior, the results indicated that the incorporation of Mg in the coatings may enhance the electrochemical performance. Mg treated surfaces did not promote greater bacterial adherence when compared to the control. MgAc 0.04 and MgAc 0.12 coatings displayed improved MC3T3-E1 pre-osteoblastic cells proliferation at day 3 compared to other groups. The hydroxyapatite formation on MgAc 0.12 surfaces was higher than in the other groups. Our data indicate that Mg precursor selection positively influences physicochemical and biological properties of coatings. Specifically, MgAc 0.12 surfaces showed the most promising surface features with greater cell proliferation, without affecting microbial colonization, being an excellent candidate for surface treatment of titanium-based dental implants.
Collapse
Affiliation(s)
- Caroline Dini
- Department of Oral Diagnosis, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | - Karen Midori Yamashita
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | - Catharina Marques Sacramento
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | - Maria Helena Rossy Borges
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | - Thais Terumi Sadamitsu Takeda
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | - João Pedro Dos Santos Silva
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | - Bruna Egumi Nagay
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | - Raphael Cavalcante Costa
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil; School of Dentistry, Federal University of Alfenas (Unifal-MG), Alfenas, Minas Gerais 37130-001, Brazil
| | - Nilson Cristino da Cruz
- Laboratory of Technological Plasmas, Engineering College, Univ Estadual Paulista (UNESP), Sorocaba, São Paulo 18087-180, Brazil
| | - Elidiane Cipriano Rangel
- Laboratory of Technological Plasmas, Engineering College, Univ Estadual Paulista (UNESP), Sorocaba, São Paulo 18087-180, Brazil
| | - Karina Gonzalez Silverio Ruiz
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil
| | - Valentim A R Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, Universidade Estadual de Campinas (UNICAMP), Piracicaba, São Paulo 13414-903, Brazil.
| |
Collapse
|
2
|
Phogat D, Awasthi S. Material and technique fundamentals of nano-hydroxyapatite coatings towards biofunctionalization: a review. Biomed Mater 2025; 20:022004. [PMID: 39837087 DOI: 10.1088/1748-605x/adac97] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Accepted: 01/21/2025] [Indexed: 01/23/2025]
Abstract
Hydroxyapatite (HAp) nanocoatings on titanium alloys (e.g. Ti6Al4V) have been used for prosthetic orthopaedic implants in recent decades because of their osseointegration, bioactivity, and biocompatibility. HAp is brittle with low mechanical strength and poor adhesion to metallic surfaces, which limits its durability and bioactivity. Surface modification techniques have alleviated the imperfections in biomaterials by coating the substrate. Several methods for improving the characteristics of implants, such as physical vapour deposition, the thermal spray method, the sol-gel method, microarc oxidation, and electrochemical deposition methods, have been discussed in this review. These processes provide mechanical strength without sacrificing biocompatibility and may lead to the development of new ideas for future research. This review discusses various selective additives, including carbon allotropes, ceramic materials, metallic materials, and multiple materials, to enhance tribological characteristics, biocompatibility, wear resistance, and mechanical strength. This review focuses on the fabrication of nano-HAps as coatings using selective deposition methods with controlled deposition parameters, paying special attention to recent developments in bone tissue engineering. This report is organized in such a way that it may inspire further research on surface modifications during medical treatment. The present review may help prospective investigators understand the importance of surface modifications for obtaining excellent implantation performance.
Collapse
Affiliation(s)
- Durgesh Phogat
- Department of Chemistry, Manipal University Jaipur, Jaipur 303007, Rajasthan, India
| | - Shikha Awasthi
- Department of Chemistry, Manipal University Jaipur, Jaipur 303007, Rajasthan, India
| |
Collapse
|
3
|
Tang S, Zhang J, Ma P, Zhang Z. Effect of ultraviolet treatment on soft tissue healing and bacterial attachment to titania-coated zirconia. Biomed Mater 2024; 20:015003. [PMID: 39419114 DOI: 10.1088/1748-605x/ad8827] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2024] [Accepted: 10/17/2024] [Indexed: 10/19/2024]
Abstract
Zirconia is the most promising implant abutment material due to its excellent aesthetic effect, good biocompatibility and corrosion resistance. To obtain ideal soft tissue sealing, the implant abutment surface should facilitate cell adhesion and inhibit bacterial colonization. In this study, pre-sintered zirconia was placed in a suspension of titania (TiO2) and zirconium oxychloride (ZrOCl2) and heated in a water bath for dense sintering. A titania coating was prepared on the zirconia surface and subjected to UV irradiation. The surface morphology, elemental composition and chemical state of each group of samples were analyzed by scanning electron microscope, x-ray energy spectrometer, x-ray photoelectron spectroscopy and x-ray diffraction. The responses of human gingival fibroblasts (HGFs) and common oral pathogensStreptococcus mutans(S. mutans) andPorphyromonas gingivalis(P. gingivalis) to modified zirconia were systematically assessed. Our findings demonstrated that the surface of titania-coated zirconia after UV irradiation produced a large number of hydroxyl groups, and its hydrophilicity was significantly improved. Meanwhile, the UV irradiation also greatly removed the hydrocarbon contaminants on the surface of the titania-coated zirconia. The UV-treated titania coating significantly promoted the proliferation, spreading, and up-regulation of adhesion-related genes and proteins of HGFs. Furthermore, the titania coating irradiated with UV could reduce the adhesion, colonization and metabolic activity ofS. mutansandP. gingivalis. Therefore, UV irradiation of titania-coated zirconia can promote the biological behavior of HGFs and exert a significant antibacterial effect, which has broad clinical application prospects for improving soft tissue integration around zirconia abutments.
Collapse
Affiliation(s)
- Shuang Tang
- Beijing Institute of Dental Research, School of Stomatology, Capital Medical University, Beijing 100050, People's Republic of China
| | - Jiebing Zhang
- Beijing Institute of Dental Research, School of Stomatology, Capital Medical University, Beijing 100050, People's Republic of China
| | - Ping Ma
- Beijing Institute of Dental Research, School of Stomatology, Capital Medical University, Beijing 100050, People's Republic of China
| | - Zutai Zhang
- Beijing Institute of Dental Research, School of Stomatology, Capital Medical University, Beijing 100050, People's Republic of China
| |
Collapse
|
4
|
Khan AA, Kim JH. Recent advances in materials and manufacturing of implantable devices for continuous health monitoring. Biosens Bioelectron 2024; 261:116461. [PMID: 38850737 DOI: 10.1016/j.bios.2024.116461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Revised: 04/30/2024] [Accepted: 06/01/2024] [Indexed: 06/10/2024]
Abstract
Implantable devices are vital in healthcare, enabling continuous monitoring, early disease detection, informed decision-making, enhanced outcomes, cost reduction, and chronic condition management. These devices provide real-time data, allowing proactive healthcare interventions, and contribute to overall improvements in patient care and quality of life. The success of implantable devices relies on the careful selection of materials and manufacturing methods. Recent materials research and manufacturing advancements have yielded implantable devices with enhanced biocompatibility, reliability, and functionality, benefiting human healthcare. This paper provides a comprehensive overview of the latest developments in implantable medical devices, emphasizing the importance of material selection and manufacturing methods, including biocompatibility, self-healing capabilities, corrosion resistance, mechanical properties, and conductivity. It explores various manufacturing techniques such as microfabrication, 3D printing, laser micromachining, electrospinning, screen printing, inkjet printing, and nanofabrication. The paper also discusses challenges and limitations in the field, including biocompatibility concerns, privacy and data security issues, and regulatory hurdles for implantable devices.
Collapse
Affiliation(s)
- Akib Abdullah Khan
- School of Engineering and Computer Science, Washington State University, Vancouver, WA, 98686, USA
| | - Jong-Hoon Kim
- School of Engineering and Computer Science, Washington State University, Vancouver, WA, 98686, USA; Department of Mechanical Engineering, University of Washington, WA, 98195, USA.
| |
Collapse
|
5
|
Narayanan R, Panigrahi M, Rautray TR, Kwon TY. Cathodic Synthesis of Strontium-Substituted Hydroxyapatite Coatings. JOM 2024; 76:4068-4074. [DOI: 10.1007/s11837-024-06663-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/14/2023] [Accepted: 05/13/2024] [Indexed: 01/06/2025]
|
6
|
Zhang J, Ren K, Qiu J, Chen B, Duan W, Liu J, Li G, Li D. Nanotexture and crystal phase regulation for synergistic enhancement in re-endothelialization on medical pure titanium surface. Mater Today Bio 2024; 25:100968. [PMID: 38312801 PMCID: PMC10835003 DOI: 10.1016/j.mtbio.2024.100968] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/20/2023] [Revised: 01/13/2024] [Accepted: 01/19/2024] [Indexed: 02/06/2024] Open
Abstract
Re-endothelialization has been recognized as a promising strategy to address the tissue hyperplasia and subsequent restenosis which are major complications associated with vascular implant/interventional titanium devices. However, the uncontrollable over-proliferation of smooth muscle cells (SMCs) limits the clinical application of numerous modified strategies. Herein, a novel modified strategy involving with a two-step anodic oxidation and annealing treatment was proposed to achieve rapid re-endothelialization function regulated by regular honeycomb nanotexture and specific anatase phase on the titanium surface. Theoretical calculation revealed that the presence of nanotexture reduced the polar component of surface energy, while the generation of anatase significantly enhanced the polar component and total surface energy. Meanwhile, the modified surface with regular nanotexture and anatase phase produced positive effect on the expression of CD31, VE-Cadherin and down-regulated α-SMA proteins expression, indicating excellent capacity of pro-endothelial regeneration and inhibition of SMCs proliferation and migration. One-month in vivo implantation in rabbit carotid arteries further confirmed that modified tube implant surface effectively accelerated confluent endothelial monolayer formation and promoted native-like endothelium tissue regeneration. By contrast, original titanium tube implant induced a disorganized tissue proliferation in the lumen with a high risk of restenosis. Collectively, this study opens us an alternative route to achieve the function that selectively promotes endothelial cells (ECs) growth and suppresses SMCs on the medical titanium surface, which has a great potential in facilitating re-endothelialization on the surface of blood-contacting titanium implant.
Collapse
Affiliation(s)
- Jing Zhang
- Advanced Medical Research Institute, Meili Lake Translational Research Park, Cheeloo College of Medicine, Shenzhen Research Institute of Shandong University, Shandong University, Jinan, Shandong, PR China
| | - Kai Ren
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, Shaanxi, PR China
| | - Jingru Qiu
- Department of Medicinal Chemistry, Key Laboratory of Chemical Biology (Ministry of Education), School of Pharmaceutical Sciences, Cheeloo College of Medicine, Shandong University, Jinan, Shandong, PR China
| | - Baolan Chen
- Advanced Medical Research Institute, Meili Lake Translational Research Park, Cheeloo College of Medicine, Shenzhen Research Institute of Shandong University, Shandong University, Jinan, Shandong, PR China
| | - Weixun Duan
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, Shaanxi, PR China
| | - Jincheng Liu
- Department of Cardiovascular Surgery, Xijing Hospital, Air Force Military Medical University, Xi'an, Shaanxi, PR China
| | - Guiling Li
- Advanced Medical Research Institute, Meili Lake Translational Research Park, Cheeloo College of Medicine, Shenzhen Research Institute of Shandong University, Shandong University, Jinan, Shandong, PR China
| | - Donghai Li
- Advanced Medical Research Institute, Meili Lake Translational Research Park, Cheeloo College of Medicine, Shenzhen Research Institute of Shandong University, Shandong University, Jinan, Shandong, PR China
| |
Collapse
|
7
|
Wang X, Li X, Che G, Zhu E, Guo H, Charpentier PA, Xu WZ, Liu C. Enhanced Photocatalytic Properties of All-Organic IDT-COOH/O-CN S-Scheme Heterojunctions Through π-π Interaction and Internal Electric Field. ACS APPLIED MATERIALS & INTERFACES 2024; 16:6367-6381. [PMID: 38270091 DOI: 10.1021/acsami.3c16123] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2024]
Abstract
Herein, we present a distinct methodology for the in situ electrostatic assembly method for synthesizing a conjugated (IDT-COOH)/oxygen-doped g-C3N4 (O-CN) S-scheme heterojunction. The electron delocalization effect due to π-π interactions between O-CN and self-assembled IDT-COOH favors interfacial charge separation. The self-assembled IDT-COOH/O-CN exhibits a broadened visible absorption to generate more charge carriers. The internal electric field between the IDT-COOH and the O-CN interface provides a directional charge-transfer channel to increase the utilization of photoinduced charge carriers. Moreover, the active species (•O2-, h+, and 1O2) produced by IDT-COOH/O-CN under visible light play important roles in photocatalytic disinfection. The optimum 40% IDT-COOH/O-CN can kill 7-log of methicillin-resistant Staphylococcus aureus (MRSA) cells in 2 h and remove 88% tetracycline (TC) in 5 h, while O-CN only inactivates 1-log of MRSA cells and degrades 40% TC. This work contributes to a promising method to fabricate all-organic g-C3N4-based S-scheme heterojunction photocatalysts with a wide range of optical responses and enhanced exciton dissociation.
Collapse
Affiliation(s)
- Xin Wang
- Jilin Joint Technology Innovation Laboratory of Developing and Utilizing Materials of Reducing Pollution and Carbon Emissions, College of Engineering, Jilin Normal University, Siping 136000, Jilin, P. R. China
| | - Xiaohuan Li
- Jilin Joint Technology Innovation Laboratory of Developing and Utilizing Materials of Reducing Pollution and Carbon Emissions, College of Engineering, Jilin Normal University, Siping 136000, Jilin, P. R. China
| | - Guangbo Che
- College of Chemistry, Baicheng Normal University, Baicheng 137000, Jilin, P. R. China
- Key Laboratory of Preparation and Application of Environmental Friendly Materials, Ministry of Education, Jilin Normal University, Changchun 130103, Jilin, P. R. China
| | - Enwei Zhu
- Key Laboratory of Preparation and Application of Environmental Friendly Materials, Ministry of Education, Jilin Normal University, Changchun 130103, Jilin, P. R. China
| | - Haiyong Guo
- Department of Biological Science, School of Life Science, Jilin Normal University, Siping 136000, Jilin, P. R. China
| | - Paul A Charpentier
- Department of Chemical and Biochemical Engineering, University of Western Ontario, London N6A 5B9, Ontario, Canada
| | - William Z Xu
- Department of Chemical and Biochemical Engineering, University of Western Ontario, London N6A 5B9, Ontario, Canada
| | - Chunbo Liu
- Jilin Joint Technology Innovation Laboratory of Developing and Utilizing Materials of Reducing Pollution and Carbon Emissions, College of Engineering, Jilin Normal University, Siping 136000, Jilin, P. R. China
- Key Laboratory of Preparation and Application of Environmental Friendly Materials, Ministry of Education, Jilin Normal University, Changchun 130103, Jilin, P. R. China
| |
Collapse
|
8
|
Park J, Tesler AB, Gongadze E, Iglič A, Schmuki P, Mazare A. Nanoscale Topography of Anodic TiO 2 Nanostructures Is Crucial for Cell-Surface Interactions. ACS APPLIED MATERIALS & INTERFACES 2024; 16:4430-4438. [PMID: 38232230 DOI: 10.1021/acsami.3c16033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/19/2024]
Abstract
Anodic titanium dioxide (TiO2) nanostructures, i.e., obtained by electrochemical anodization, have excellent control over the nanoscale morphology and have been extensively investigated in biomedical applications owing to their sub-100 nm nanoscale topography range and beneficial effects on biocompatibility and cell interactions. Herein, we obtain TiO2 nanopores (NPs) and nanotubes (NTs) with similar morphologies, namely, 15 nm diameter and 500 nm length, and investigate their characteristics and impact on stem cell adhesion. We show that the transition of TiO2 NPs to NTs occurs via a pore/wall splitting mechanism and the removal of the fluoride-rich layer. Furthermore, in contrast to the case of NPs, we observe increased cell adhesion and proliferation on nanotubes. The enhanced mesenchymal stem cell adhesion/proliferation seems to be related to a 3-fold increase in activated integrin clustering, as confirmed by immunogold labeling with β1 integrin antibody on the nanostructured layers. Moreover, computations of the electric field and surface charge density show increased values at the inner and outer sharp edges of the top surfaces of the NTs, which in turn can influence cell adhesion by increasing the bridging interactions mediated by proteins and molecules in the environment. Collectively, our results indicate that the nanoscale surface architecture of the lateral spacing topography can greatly influence stem cell adhesion on substrates for biomedical applications.
Collapse
Affiliation(s)
- Jung Park
- Division of Molecular Pediatrics, Department of Pediatrics, University Hospital Erlangen, 91054 Erlangen, Germany
| | - Alexander B Tesler
- Department of Materials Science WW4-LKO, Friedrich-Alexander University of Erlangen Nürnberg, 91054 Erlangen, Germany
| | - Ekaterina Gongadze
- Laboratory of Physics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana SI-1000, Slovenia
| | - Aleš Iglič
- Laboratory of Physics, Faculty of Electrical Engineering, University of Ljubljana, Tržaška 25, Ljubljana SI-1000, Slovenia
- Laboratory of Clinical Biophysics, Faculty of Medicine, University of Ljubljana, Vrazov Trg 2, Ljubljana 1000, Slovenia
| | - Patrik Schmuki
- Department of Materials Science WW4-LKO, Friedrich-Alexander University of Erlangen Nürnberg, 91054 Erlangen, Germany
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute, Palacky University, Olomouc 779 00, Czech Republic
| | - Anca Mazare
- Department of Materials Science WW4-LKO, Friedrich-Alexander University of Erlangen Nürnberg, 91054 Erlangen, Germany
| |
Collapse
|
9
|
Tworek P, Rakowski K, Szota M, Lekka M, Jachimska B. Changes in Secondary Structure and Properties of Bovine Serum Albumin as a Result of Interactions with Gold Surface. Chemphyschem 2024; 25:e202300505. [PMID: 38009440 DOI: 10.1002/cphc.202300505] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2023] [Revised: 11/17/2023] [Accepted: 11/19/2023] [Indexed: 11/28/2023]
Abstract
Proteins can alter their shape when interacting with a surface. This study explores how bovine serum albumin (BSA) modifies structurally when it adheres to a gold surface, depending on the protein concentration and pH. We verified that the gold surface induces significant structural modifications to the BSA molecule using circular dichroism, infrared spectroscopy, and atomic force microscopy. Specifically, adsorbed molecules displayed increased levels of disordered structures and β-turns, with fewer α-helices than the native structure. MP-SPR spectroscopy demonstrated that the protein molecules preferred a planar orientation during adsorption. Molecular dynamics simulations revealed that the interaction between cysteines exposed to the outside of the molecule and the gold surface was vital, especially at pH=3.5. The macroscopic properties of the protein film observed by AFM and contact angles confirm the flexible nature of the protein itself. Notably, structural transformation is joined with the degree of hydration of protein layers.
Collapse
Affiliation(s)
- Paulina Tworek
- Jerzy Haber Institute of Catalysis and Surface Chemistry Polish Academy of Sciences, Niezapominajek 8, 30-239, Krakow, Poland
| | - Kamil Rakowski
- Jerzy Haber Institute of Catalysis and Surface Chemistry Polish Academy of Sciences, Niezapominajek 8, 30-239, Krakow, Poland
| | - Magdalena Szota
- Jerzy Haber Institute of Catalysis and Surface Chemistry Polish Academy of Sciences, Niezapominajek 8, 30-239, Krakow, Poland
| | - Małgorzata Lekka
- Department of Biophysical Microstructures, Henryk Niewodniczanski Institute of Nuclear Physics, Polish Academy of Sciences, 31-342, Krakow, Poland
| | - Barbara Jachimska
- Jerzy Haber Institute of Catalysis and Surface Chemistry Polish Academy of Sciences, Niezapominajek 8, 30-239, Krakow, Poland
| |
Collapse
|
10
|
Borges GA, Costa RC, Nagay BE, Sacramento CM, Ruiz KGS, Solano de Almeida L, Rossino LS, Fortulan CA, Rangel EC, Barão VAR, Mesquita MF. Targeting Biomechanical Endurance of Dental-Implant Abutments Using a Diamond-Like Carbon Coating. ACS APPLIED BIO MATERIALS 2023; 6:5630-5643. [PMID: 38052058 DOI: 10.1021/acsabm.3c00802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/07/2023]
Abstract
Abutment components (i.e., fixtures associated with oral implants) are essentially made of titanium (Ti), which is continuously exposed to the hash oral environment, resulting in scratching. Thus, such components need to be protected, and surface treatments are viable methods for overcoming long-term damage. Diamond-like carbon (DLC), an excellent protective material, is an alternative surface-treatment material for Ti abutments. Here, we demonstrate that a silicon interlayer for DLC film growth and the pulsed-direct current plasma-enhanced chemical vapor deposition (DC-PECVD) method enables the deposition of an enhanced protective DLC film. As a result, the DLC film demonstrated a smooth topography with a compact surface. Furthermore, the DLC film enhanced the mechanical (load-displacement, hardness, and elastic modulus) and tribological properties of Ti as well as increased its corrosion resistance (16-fold), which surpassed that of a bare Ti substrate. The biofilm formed (Streptococcus sanguinis) after 24 h exhibited an equal bacterial load (∼7 Log colony-forming units) for both the groups (Ti and DLC). In addition, the DLC film exhibited good cytocompatibility, owing to its noncytotoxicity toward human gingival fibroblast cells. Therefore, DLC deposition via DC-PECVD can be considered to be a promising protective and cytocompatible alternative for developing implant abutments with enhanced mechanical, tribological, and electrochemical properties.
Collapse
Affiliation(s)
- Guilherme Almeida Borges
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Raphael Cavalcante Costa
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Bruna Egumi Nagay
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Catharina Marques Sacramento
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Karina Gonzales Silverio Ruiz
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Larissa Solano de Almeida
- Federal University of São Carlos (UFSCar) - Campus Sorocaba, Postgraduate Program in Materials Science, Rodovia João Leme dos Santos, Km 110, Sorocaba, São Paulo 18052-780, Brazil
| | - Luciana Sgarbi Rossino
- Federal University of São Carlos (UFSCar) - Campus Sorocaba, Postgraduate Program in Materials Science, Rodovia João Leme dos Santos, Km 110, Sorocaba, São Paulo 18052-780, Brazil
- State Center of Technological Education "Paula Souza" (CEETEPS), Sorocaba Technology College - Campus Sorocaba (Fatec Sorocaba), Avenida Engenheiro Carlos Reinaldo Mendes, 2015, Sorocaba, São Paulo 18013-280, Brazil
| | - Carlos Alberto Fortulan
- University of São Paulo (USP), Department of Mechanical Engineering, Trabalhador São Carlense 400, São Carlos, São Paulo 13566-590, Brazil
| | - Elidiane Cipriano Rangel
- São Paulo State University (UNESP), Institute of Science and Technology, Laboratory of Technological Plasmas, Avenida Três de Março, 51, Sorocaba, São Paulo 18087-180, Brazil
| | - Valentim A R Barão
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Marcelo Ferraz Mesquita
- University of Campinas (UNICAMP), Piracicaba Dental School, Department of Prosthodontics and Periodontics, Avenida Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| |
Collapse
|
11
|
Rogala-Wielgus D, Majkowska-Marzec B, Zieliński A, Roszek K, Liszewska M. Evaluation of adhesion strength, corrosion, and biological properties of the MWCNT/TiO 2 coating intended for medical applications. RSC Adv 2023; 13:30108-30117. [PMID: 37849700 PMCID: PMC10577579 DOI: 10.1039/d3ra05331h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2023] [Accepted: 09/18/2023] [Indexed: 10/19/2023] Open
Abstract
Multi-wall carbon nanotube (MWCNT) coatings are gaining increasing interest because of their special properties used in many science fields. The titania coatings are known for their improvement of osteoblast adhesion, thus changing the surface architecture. Bi-layer coatings comprising 0.25 wt% of the MWCNTs and 0.30 wt% of titania (anatase structure) were synthesized in a two-stage procedure using the electrophoretic deposition method (EPD). The MWCNT and TiO2 coatings were deposited with voltage and time parameters, respectively, of 20 V and 0.5 min, and 50 V and 4 min. EDS, AFM, SEM, Raman spectroscopy, nano-scratch test, potentiodynamic corrosion tests, wettability studies, and cytotoxicity determined with MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) test on human dermal fibroblasts (HDF) and mouse osteoblast precursors (MC3T3), and lactate dehydrogenase (LDH) activity test were carried out on examined surfaces. The prepared MWCNT/TiO2 coating is uniformly distributed by MWCNTs and agglomerated by TiO2 particles of size ranging from 0.1 to 3 μm. Raman spectroscopy confirmed the anatase structure of the TiO2 addition and showed typical peaks of the MWCNTs. The MWCNT/TiO2 coating had higher roughness, higher adhesion strength, and improved corrosion resistance compared to the MWCNT basic coating. The results of biological tests proved that physicochemical properties of the surface, such as high porosity and wettability of MWCNT/TiO2-coated material, would support cell adhesion, but toxic species could be released to the culture medium, thus resulting in a decrease in proliferation.
Collapse
Affiliation(s)
- Dorota Rogala-Wielgus
- Division of Biomaterials Technology, Institute of Manufacturing and Materials Technology, Faculty of Mechanical Engineering and Ship Technology, Gdansk University of Technology 11 Narutowicza Str. 80-233 Gdańsk Poland
| | - Beata Majkowska-Marzec
- Division of Biomaterials Technology, Institute of Manufacturing and Materials Technology, Faculty of Mechanical Engineering and Ship Technology, Gdansk University of Technology 11 Narutowicza Str. 80-233 Gdańsk Poland
| | - Andrzej Zieliński
- Division of Biomaterials Technology, Institute of Manufacturing and Materials Technology, Faculty of Mechanical Engineering and Ship Technology, Gdansk University of Technology 11 Narutowicza Str. 80-233 Gdańsk Poland
| | - Katarzyna Roszek
- Faculty of Biological and Veterinary Sciences, Nicolaus Copernicus University in Toruń Lwowska 1 Str. 87-100 Toruń Poland
| | - Malwina Liszewska
- Institute of Optoelectronics, Military University of Technology Kaliskiego 2 Str. 00-908 Warsaw Poland
| |
Collapse
|
12
|
Alhamad M, Barão VA, Sukotjo C, Yerokhin A, Mathew MT. Unpredictable Electrochemical Processes in Ti Dental Implants: The Role of Ti Ions and Inflammatory Products. ACS APPLIED BIO MATERIALS 2023; 6:3661-3673. [PMID: 37602778 DOI: 10.1021/acsabm.3c00235] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/22/2023]
Abstract
Peri-implantitis is a substantially prevailing condition. A potential risk factor for peri-implantitis is Ti implant corrosion. During inflammation, substantial quantities of reactive oxygen species (ROS) secretion and local acidification occur. Little is known about the interaction between the inflammatory and corrosion products on Ti surface corrosion. Therefore, the objective of the current study was to evaluate the synergistic effect of hydrogen peroxide (H2O2), lactic acid, and Ti ions on Ti corrosion. Twenty-seven commercially pure Ti samples were polished (Ra ≈ 45 nm) and divided into 9 groups as a function of electrolyte: (1) artificial saliva (AS) as control (C), (2) AS + Ti ions 20 ppm (Ti), (3) AS + lactic acid (pH = 5.5) (L), (4) AS + lactic acid + Ti ions 20 ppm (TiL), (5) AS + H2O2 0.5 mM (HP0.5), (6) AS + H2O2 1.0 mM (HP1.0), (7) AS + H2O2 0.5 mM + Ti ions 20 ppm (HP0.5Ti), (8) AS + H2O2 0.5 mM + lactic acid (HP0.5L), and (9) AS + H2O2 0.5 mM + Ti ions 20 ppm + lactic acid (HP0.5TiL). Electrochemical tests were performed following ASMT guidelines. Based on Tafel's method, current density (icorr) and corresponding potential (Ecorr) were acquired from potentiodynamic curves. Using electrochemical intensity spectroscopy (EIS), Nyquist and Bode plots were derived. Using a modified Randles circuit, charge transfer resistance (Rct) and capacitance (Cdl) were estimated. Based on open-circuit potential data, groups C and Ti had the lowest potentials (around -0.3 and -0.4 V vs SCE, respectively), indicating a lower passivation tendency compared to the other groups. From potentiodynamic curves, groups HP0.5 and HP1.0 increased icorr the most. From EIS data, groups HP0.5 and HP1.0 demonstrated the lowest impedance and phase angle on the Bode plot, indicating the highest corrosion kinetics. Based on EIS modeling, the combination of Ti ions, lactic acid, and H2O2 (group HP0.5TiL) significantly decreased Rct (p < 0.05). In conclusion, the concurrent presence of Ti ions, lactic acid, and H2O2 in the vicinity of the Ti surface increased the corrosion kinetics. High corrosion may produce more Ti products in the peri-implant tissues, which may increase the potential risk of peri-implantitis.
Collapse
Affiliation(s)
- Mostafa Alhamad
- Department of Restorative Dentistry, University of Illinois at Chicago, College of Dentistry, Chicago, Illinois 60612, United States
- Department of Restorative Dental Sciences, Imam Abdulrahman Bin Faisal University, College of Dentistry, Dammam 34212, Saudi Arabia
| | - Valentim Adelino Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas, (UNICAMP), Piracicaba 13414-903, São Paulo, Brazil
| | - Cortino Sukotjo
- Department of Restorative Dentistry, University of Illinois at Chicago, College of Dentistry, Chicago, Illinois 60612, United States
| | - Aleksey Yerokhin
- Department of Materials, University of Manchester, Oxford Road, Manchester M13 9PL, U.K
| | - Mathew Thoppil Mathew
- Department of Restorative Dentistry, University of Illinois at Chicago, College of Dentistry, Chicago, Illinois 60612, United States
- Department of Biomedical Sciences, University of Illinois, College of Medicine, Rockford, Illinois 61107, United States
| |
Collapse
|
13
|
Silva JPDS, Costa RC, Nagay BE, Borges MHR, Sacramento CM, da Cruz NC, Rangel EC, Fortulan CA, da Silva JHD, Ruiz KGS, Barão VAR. Boosting Titanium Surfaces with Positive Charges: Newly Developed Cationic Coating Combines Anticorrosive and Bactericidal Properties for Implant Application. ACS Biomater Sci Eng 2023; 9:5389-5404. [PMID: 37561763 DOI: 10.1021/acsbiomaterials.3c00491] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/12/2023]
Abstract
Along with poor implant-bone integration, peri-implant diseases are the major causes of implant failure. Although such diseases are primarily triggered by biofilm accumulation, a complex inflammatory process in response to corrosive-related metallic ions/debris has also been recognized as a risk factor. In this regard, by boosting the titanium (Ti) surface with silane-based positive charges, cationic coatings have gained increasing attention due to their ability to kill pathogens and may be favorable for corrosion resistance. Nevertheless, the development of a cationic coating that combines such properties in addition to having a favorable topography for implant osseointegration is lacking. Because introducing hydroxyl (-OH) groups to Ti is essential to increase chemical bonds with silane, Ti pretreatment is of utmost importance to achieve such polarization. In this study, plasma electrolytic oxidation (PEO) was investigated as a new route to pretreat Ti with OH groups while providing favorable properties for implant application compared with traditional hydrothermal treatment (HT). To produce bactericidal and corrosion-resistant cationic coatings, after pretreatment with PEO or HT (Step 1), surface silanization was subsequently performed via immersion-based functionalization with 3-aminopropyltriethoxysilane (APTES) (Step 2). In the end, five groups were assessed: untreated Ti (Ti), HT, PEO, HT+APTES, and PEO+APTES. PEO created a porous surface with increased roughness and better mechanical and tribological properties compared with HT and Ti. The introduction of -OH groups by HT and PEO was confirmed by Fourier transform infrared spectroscopy and the increase in wettability producing superhydrophilic surfaces. After silanization, the surfaces were polarized to hydrophobic ones, and an increase in the amine functional group was observed by X-ray photoelectron spectroscopy, demonstrating a considerable amount of positive ions. Such protonation may explain the enhanced corrosion resistance and dead bacteria (Streptococcus aureus and Escherichia coli) found for PEO+APTES. All groups presented noncytotoxic properties with similar blood plasma protein adsorption capacity vs the Ti control. Our findings provide new insights into developing next-generation cationic coatings by suggesting that a tailorable porous and oxide coating produced by PEO has promise in designing enhanced cationic surfaces targeting biomedical and dental implant applications.
Collapse
Affiliation(s)
- João Pedro Dos S Silva
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Raphael C Costa
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Bruna E Nagay
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Maria H R Borges
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Catharina M Sacramento
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Nilson C da Cruz
- Laboratory of Technological Plasmas, Institute of Science and Technology, São Paulo State University (UNESP), Av. Três de Março, 511, Sorocaba, São Paulo 18087-180, Brazil
| | - Elidiane C Rangel
- Laboratory of Technological Plasmas, Institute of Science and Technology, São Paulo State University (UNESP), Av. Três de Março, 511, Sorocaba, São Paulo 18087-180, Brazil
| | - Carlos A Fortulan
- Department of Mechanical Engineering, University of São Paulo (USP), Trabalhador São Carlense, 400, São Carlos, São Paulo 13566-590, Brazil
| | - José H D da Silva
- Department of Physics, School of Sciences, São Paulo State University (UNESP), Av. Eng. Luís Edmundo C. Coube, 14-01, Bauru, São Paulo 17033-360, Brazil
| | - Karina G S Ruiz
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| | - Valentim A R Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas (UNICAMP), Av. Limeira, 901, Piracicaba, São Paulo 13414-903, Brazil
| |
Collapse
|
14
|
First-Principles Study on the Adsorption Characteristics of Corrosive Species on Passive Film TiO2 in a NaCl Solution Containing H2S and CO2. METALS 2022. [DOI: 10.3390/met12071160] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
The adsorption characteristics of corrosive anions (Cl−, HS−, S2−, HCO3− and CO32−) on TiO2 of TC4 titanium alloy in a NaCl solution containing H2S and CO2 were studied by density functional theory (DFT). The stable adsorption configuration of each corrosive species on the TiO2 (110) surface was obtained by geometric optimization, and the electronic structure and interface binding energy were calculated and analyzed. The results showed that the optimal adsorption positions of Cl−, HS−, S2−, HCO3−and CO32− on TiO2 (110) were all bridge positions. There was a strong charge interaction between the negatively charged Cl, S and O atoms in Cl−, HS−, S2−, HCO3− and CO32− and the positively charged Ti atoms of TiO2. The interface bonding was mainly caused by charge movement from around Ti atoms to around Cl, O, S atoms. The energy levels were mainly caused by the electron orbital hybridization of Cl-3p5, S-3p4, O-2p4 and Ti-3d2. All adsorption configurations were chemical adsorption. The order of influence of the five ions on the stability of TiO2 was S2− > CO32− > Cl− > HS− > HCO3−. Finally, a novel corrosion mechanism was proposed to illustrate the dynamic evolution processes of pits.
Collapse
|
15
|
Kuźmicz-Mirosław E, Kuśmierz M, Terpiłowski K, Śmietana M, Barczak M, Staniszewska M. Effect of Various Surface Treatments on Wettability and Morphological Properties of Titanium Oxide Thin Films. MATERIALS 2022; 15:ma15124113. [PMID: 35744176 PMCID: PMC9227497 DOI: 10.3390/ma15124113] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Revised: 06/02/2022] [Accepted: 06/04/2022] [Indexed: 02/01/2023]
Abstract
The effect of three popular surface activation methods for a titanium oxide (titania) surface was thoroughly investigated to identify the most effective protocol for the enhancement of hydrophilicity. All the methods, namely H2O2 activation, UV irradiation and oxygen plasma treatment resulted in an enhanced hydrophilic titania surface, which was evidenced by the reduced contact angle values. To study in detail the chemical and morphological features responsible for the increased hydrophilicity, the treated surfaces were submitted to inspection with atomic force microscopy and X-ray photoelectron spectroscopy. The correlation between the treatment and titania surface hydroxylation as well as hydrophilic behavior have been discussed.
Collapse
Affiliation(s)
| | - Marcin Kuśmierz
- Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland; (M.K.); (K.T.)
| | - Konrad Terpiłowski
- Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland; (M.K.); (K.T.)
| | - Mateusz Śmietana
- Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warszawa, Poland;
| | - Mariusz Barczak
- Institute of Chemical Sciences, Faculty of Chemistry, Maria Curie-Sklodowska University, Maria Curie-Sklodowska Sq. 3, 20-031 Lublin, Poland; (M.K.); (K.T.)
- Correspondence: (M.B.); (M.S.); Tel.: +48-81-537-79-92 (M.B.); +48-81-501-94-63 (M.S.)
| | - Magdalena Staniszewska
- SDS Optic S.A. Głęboka 39, 20-612 Lublin, Poland;
- Correspondence: (M.B.); (M.S.); Tel.: +48-81-537-79-92 (M.B.); +48-81-501-94-63 (M.S.)
| |
Collapse
|
16
|
Oirschot BV, zhang Y, Alghamdi HS, cordeiro JM, nagay B, barão VA, de avila ED, van den Beucken J. Surface engineering for dental implantology: favoring tissue responses along the implant
. Tissue Eng Part A 2022; 28:555-572. [DOI: 10.1089/ten.tea.2021.0230] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022] Open
Affiliation(s)
- Bart van Oirschot
- Radboudumc Department of Dentistry, 370502, Regenerative Biomaterials, Nijmegen, Gelderland, Netherlands,
| | - yang zhang
- Shenzhen University, 47890, School of Stomatology, Health Science Center, Shenzhen, Guangdong, China,
| | - Hamdan S Alghamdi
- King Saud University College of Dentistry, 204573, Department of Periodontics and Community Dentistry, College of Dentistry, King Saud University, Riyadh, Saudi Arabia,
| | - jairo m cordeiro
- UNICAMP, 28132, Department of Prosthodontics and Periodontology, Piracicaba Dental School, Campinas, SP, Brazil,
| | - bruna nagay
- UNICAMP, 28132, Department of Prosthodontics and Periodontology, Piracicaba Dental School, Campinas, SP, Brazil,
| | - valentim ar barão
- UNICAMP, 28132, Department of Prosthodontics and Periodontology, Piracicaba Dental School, Campinas, SP, Brazil,
| | - erica dorigatti de avila
- UNESP, 28108, Department of Dental Materials and Prosthodontics, School of Dentistry at Araraquara, São Paulo State University (UNESP), Sao Paulo, SP, Brazil,
| | - Jeroen van den Beucken
- Radboudumc Department of Dentistry, 370502, Regenerative Biomaterials, Nijmegen, Gelderland, Netherlands,
- RU RIMLS, 59912, Nijmegen, Gelderland, Netherlands,
| |
Collapse
|
17
|
Wu J, Yang J, Wang Y, Wang Y, Yu H, Han J, Zhang J. Biocompatible Coating on Micro‐structured Titanium Implants with Enhanced Osteogenesis to Facilitate Bone‐implant Integration. ChemistrySelect 2022. [DOI: 10.1002/slct.202103540] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
Affiliation(s)
- Jiannan Wu
- Department of Implantology Tianjin Stomatological Hospital School of Medicine Nankai University Tianjin 300041 China
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction Tianjin 300041 China
| | - Jing Yang
- Department of Implantology Tianjin Stomatological Hospital School of Medicine Nankai University Tianjin 300041 China
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction Tianjin 300041 China
| | - Yanying Wang
- Department of Implantology Tianjin Stomatological Hospital School of Medicine Nankai University Tianjin 300041 China
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction Tianjin 300041 China
| | - Yanduo Wang
- Department of Implantology Tianjin Stomatological Hospital School of Medicine Nankai University Tianjin 300041 China
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction Tianjin 300041 China
| | - Haiyang Yu
- Department of Implantology Tianjin Stomatological Hospital School of Medicine Nankai University Tianjin 300041 China
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction Tianjin 300041 China
| | - Jing Han
- Department of Implantology Tianjin Stomatological Hospital School of Medicine Nankai University Tianjin 300041 China
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction Tianjin 300041 China
| | - Jian Zhang
- Department of Implantology Tianjin Stomatological Hospital School of Medicine Nankai University Tianjin 300041 China
- Tianjin Key Laboratory of Oral and Maxillofacial Function Reconstruction Tianjin 300041 China
| |
Collapse
|
18
|
Insight Into Corrosion of Dental Implants: From Biochemical Mechanisms to Designing Corrosion-Resistant Materials. CURRENT ORAL HEALTH REPORTS 2022; 9:7-21. [PMID: 35127334 PMCID: PMC8799988 DOI: 10.1007/s40496-022-00306-z] [Citation(s) in RCA: 17] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Accepted: 01/21/2022] [Indexed: 02/07/2023]
Abstract
Purpose of Review Despite advanced technologies to avoid corrosion of dental implants, the mechanisms toward the release of metals and their role in the onset of peri-implant diseases are still under-investigated. Effective knowledge on the etiopathogenesis of corrosive products and preventive strategies mitigating the risks for surface degradation are thus in dire need. This review aimed to summarize evidence toward biocorrosion in the oral environment and discuss the current strategies targeting the improvement of dental implants and focusing on the methodological and electrochemical aspects of surface treatments and titanium-based alloys. Recent Findings Recent studies suggest the existence of wear/corrosion products may correlate with peri-implantitis progress by triggering microbial dysbiosis, the release of pro-inflammatory cytokines, and animal bone resorption. Furthermore, current clinical evidence demonstrating the presence of metal-like particles in diseased tissues supports their possible role as a risk factor for peri-implantitis. For instance, to overcome the drawback of titanium corrosion, researchers are primarily focusing on developing corrosion-resistant alloys and coatings for dental implants by changing their physicochemical features. Summary The current state-of-art discussed in this review found corrosion products effective in affecting biofilm virulence and inflammatory factors in vitro. Controversial and unstandardized data are limitations, making the premise of corrosion products being essential for peri-implantitis onset. On the other hand, when it comes to the strategies toward reducing implant corrosion rate, it is evident that the chemical and physical properties are crucial for the in vitro electrochemical behavior of the implant material. For instance, it is foreseeable that the formation of films/coatings and the incorporation of some functional compounds into the substrate may enhance the material’s corrosion resistance and biological response. Nevertheless, the utmost challenge of research in this field is to achieve adequate stimulation of the biological tissues without weakening its protective behavior against corrosion. In addition, the translatability from in vitro findings to clinical studies is still in its infancy. Therefore, further accumulation of high-level evidence on the role of corrosion products on peri-implant tissues is expected to confirm the findings of the present review besides the development of better methods to improve the corrosion resistance of dental implants. Furthermore, such knowledge could further develop safe and long-term implant rehabilitation therapy.
Collapse
|
19
|
Cordeiro JM, Nagay BE, Dini C, Souza JG, Rangel EC, da Cruz NC, Yang F, van den Beucken JJ, Barão VA. Copper source determines chemistry and topography of implant coatings to optimally couple cellular responses and antibacterial activity. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 134:112550. [DOI: 10.1016/j.msec.2021.112550] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Revised: 10/16/2021] [Accepted: 11/10/2021] [Indexed: 12/12/2022]
|
20
|
Alhamad M, Barão VAR, Sukotjo C, Cooper LF, Mathew MT. Ti-Ions and/or Particles in Saliva Potentially Aggravate Dental Implant Corrosion. MATERIALS 2021; 14:ma14195733. [PMID: 34640130 PMCID: PMC8510105 DOI: 10.3390/ma14195733] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/27/2021] [Revised: 09/17/2021] [Accepted: 09/27/2021] [Indexed: 11/16/2022]
Abstract
The corrosive titanium products in peri-implant tissues are a potential risk factor for peri-implantitis. There is very limited information available on the effect of the corrosion and wear products on the dental implant corrosion. Therefore, we determined the influence of Ti-ions and Ti-particles on Ti corrosion. Eighteen commercially pure-Ti-grade-2 discs were polished to mirror-shine. Samples were divided into six groups (n = 3) as a function of electrolytes; (A) Artificial saliva (AS), (B) AS with Ti-ions (the electrolyte from group A, after corrosion), (C) AS with Ti-particles 10 ppm (D) AS with Ti-particles 20 ppm, (E) AS with Ti-ions 10 ppm, and (F) AS with Ti-ions 20 ppm. Using Tafel’s method, corrosion potential (Ecorr) and current density (Icorr) were estimated from potentiodynamic curves. Electrochemical Impedance Spectroscopy (EIS) data were used to construct Nyquist and Bode plots, and an equivalent electrical circuit was used to assess the corrosion kinetics. The corroded surfaces were examined through a 3D-white-light microscope and scanning electronic microscopy. The data demonstrated that the concentration of Ti-ions and corrosion rate (Icorr) are strongly correlated (r = 0.997, p = 0.046). This study indicated that high Ti-ion concentration potentially aggravates corrosion. Under such a severe corrosion environment, there is a potential risk of increased implant associated adverse tissue reactions.
Collapse
Affiliation(s)
- Mostafa Alhamad
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, IL 60612, USA;
- Department of Restorative Dental Sciences, College of Dentistry, Imam Abdulrahman Bin Faisal University, Dammam 34212, Saudi Arabia
| | - Valentim A. R. Barão
- Department of Prosthodontics and Periodontology, Piracicaba Dental School, University of Campinas, Piracicaba, São Paulo 13414-903, Brazil;
| | - Cortino Sukotjo
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, IL 60612, USA;
- Department of Prosthodontics, School of Dental Medicine, Bahçeşehir University, Istanbul 34353, Turkey
- Correspondence: (C.S.); (M.T.M.)
| | - Lyndon F. Cooper
- Department of Oral Biology, College of Dentistry, University of Illinois at Chicago, Chicago, IL 60612, USA;
| | - Mathew T. Mathew
- Department of Restorative Dentistry, College of Dentistry, University of Illinois at Chicago, Chicago, IL 60612, USA;
- Correspondence: (C.S.); (M.T.M.)
| |
Collapse
|
21
|
Manivasagam VK, Sabino RM, Kantam P, Popat KC. Surface modification strategies to improve titanium hemocompatibility: a comprehensive review. MATERIALS ADVANCES 2021; 2:5824-5842. [PMID: 34671743 PMCID: PMC8451052 DOI: 10.1039/d1ma00367d] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/21/2021] [Accepted: 07/27/2021] [Indexed: 05/31/2023]
Abstract
Titanium and its alloys are widely used in different biomaterial applications due to their remarkable mechanical properties and bio-inertness. However, titanium-based materials still face some challenges, with an emphasis on hemocompatibility. Blood-contacting devices such as stents, heart valves, and circulatory devices are prone to thrombus formation, restenosis, and inflammation due to inappropriate blood-implant surface interactions. After implantation, when blood encounters these implant surfaces, a series of reactions takes place, such as protein adsorption, platelet adhesion and activation, and white blood cell complex formation as a defense mechanism. Currently, patients are prescribed anticoagulant drugs to prevent blood clotting, but these drugs can weaken their immune system and cause profound bleeding during injury. Extensive research has been done to modify the surface properties of titanium to enhance its hemocompatibility. Results have shown that the modification of surface morphology, roughness, and chemistry has been effective in reducing thrombus formation. The main focus of this review is to analyze and understand the different modification techniques on titanium-based surfaces to enhance hemocompatibility and, consequently, recognize the unresolved challenges and propose scopes for future research.
Collapse
Affiliation(s)
| | - Roberta M Sabino
- School of Advanced Materials Discovery, Colorado State University Fort Collins CO USA
| | - Prem Kantam
- Department of Mechanical Engineering, Colorado State University Fort Collins CO USA
| | - Ketul C Popat
- Department of Mechanical Engineering, Colorado State University Fort Collins CO USA
- School of Advanced Materials Discovery, Colorado State University Fort Collins CO USA
- School of Biomedical Engineering, Colorado State University Fort Collins CO USA
| |
Collapse
|