1
|
Anderl C, Steinmair M, Hochreiter J. Bone Preservation in Total Hip Arthroplasty. J Arthroplasty 2022; 37:1118-1123. [PMID: 35121089 DOI: 10.1016/j.arth.2022.01.077] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/14/2021] [Revised: 12/27/2021] [Accepted: 01/22/2022] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Preserving bone stock in younger and more active patients after total hip arthroplasty (THA) is important for future revision. Newer prosthesis designs, including short femoral stems and isoelastic acetabular cups, are likely to preserve more bone stock. However, long-term follow-up studies on bone remodeling after short-stem THA with an isoelastic monoblock acetabular cup are few. Therefore, we evaluated bone preservation after THA using these prostheses at a 5-year follow-up. METHODS This prospective observational study is a 5-year follow-up of our previously reported 2-year observational study on the same cohort of patients. We included 45 patients with primary osteoarthritis treated with a calcar-guided femoral short-stem prosthesis and a monoblock press-fit acetabular cup. We evaluated bone mineral density (BMD) around the prostheses using dual-energy X-ray absorptiometry and reported functional outcomes preoperatively and at 3, 12, 24, and 60 months postoperatively. All complications were recorded. RESULTS At the final follow-up, the BMD was comparable with that at 24 months in Gruen zones 3, 4, 5, 6, and 7, whereas it significantly differed in Gruen zones 1 (P < .0001) and 2 (P < .004). On the acetabular side, the BMD leveled off similarly in all DeLee and Charnley zones between 24 and 60 months (P > .05). Moreover, all measured clinical outcomes significantly improved (P < .001). One perioperative dislocation was reported. CONCLUSION Patients undergoing THA with a calcar-guided femoral short-stem prosthesis and a monoblock acetabular cup can expect preservation of bone stock over a longer follow-up with excellent clinical outcomes and few complications.
Collapse
Affiliation(s)
- Conrad Anderl
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Linz, Austria
| | - Martin Steinmair
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Linz, Austria
| | - Josef Hochreiter
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Linz, Austria
| |
Collapse
|
2
|
Mahmood FF, Beck M, de Gast A, Rehbein P, French GJ, Becker R, Dominkus M, Helmy N, Hollmann L, Baines J. Survivorship and Patient-Reported Outcomes of an Uncemented Vitamin E-Infused Monoblock Acetabular Cup: A Multicenter Prospective Cohort Study. J Arthroplasty 2021; 36:1700-1706. [PMID: 33516632 DOI: 10.1016/j.arth.2020.12.032] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/03/2020] [Revised: 12/16/2020] [Accepted: 12/18/2020] [Indexed: 02/02/2023] Open
Abstract
BACKGROUND Addition of vitamin E to polyethylene is theorized to reduce the potential for oxidative wear in acetabular components. This paper presents a multicenter prospective cohort study that reports on outcomes from use of a Vitamin E-infused highly cross-linked polyethylene acetabular cup. METHODS Patients were recruited across nine medical institutions. Clinical outcome measures recorded were the Harris Hip Score, visual analogue score for pain and satisfaction. Evidence of implant loosening or osteolysis was collected radiologically. Cup survival and reasons for revision in relevant cases were also recorded. Data collection was undertaken preoperatively, at 6-12 weeks, 6 months, 1 year, 2 years, and 5 years. A total of 675 patients were recruited, with 450 cases available at final review. Data regarding cup survival was available to 8 years and 9 months postoperatively. RESULTS Improvements in both the Harris Hip Score and visual analogue score for pain and satisfaction were recorded at all time points, with these being maintained through the length of follow-up. In total, 89% of cups were implanted within the Lewinnek safe zone. A lucent line was identified in one case, with no evidence of acetabular osteolysis observed throughout the follow-up period. Cup survival was 98.9% at 8 years and 9 months. No revisions for aseptic loosening were observed. CONCLUSIONS The use of a vitamin E-infused polyethylene acetabular cup demonstrates reassuring patient-reported outcomes, radiological measures, and cup survival at medium to long-term follow-up.
Collapse
Affiliation(s)
- Fahd F Mahmood
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| | - Martin Beck
- Luzerner Kantonsspital, Luzern, Switzerland; Orthopaedic Clinic Lucerne, Hirslanden Clinic St. Anna, Lucerne
| | - Arthur de Gast
- Diakonessenhuis Utrecht, Utrecht, the Netherlands; Clinical Orthopedic Research Center Midden-Nederland, Diakonessenhuis Zeist, Zeist, the Netherlands
| | - Philipp Rehbein
- Department of Orthopaedics, St. Josefs-Hospital Wiesbaden, Wiesbaden, Germany
| | | | - Roland Becker
- Dept. of Orthopedics and Traumatology, Brandenburg Medical School, Brandenburg, Germany
| | - Martin Dominkus
- Orthopaedic Department, Orthopädisches Spital Speising, Wien, Austria; Sigmund Freud University, Campus Prater Freudplatz 1, Wien, Austria
| | - Naeder Helmy
- Department of Orthopaedics, Nurgerspital Solothurn, Solothurn, Switzerland
| | - Lutz Hollmann
- Streekziekenhuis Koningin Beatrix, Winterswijk, the Netherlands
| | - Joe Baines
- Department of Orthopaedics, Golden Jubilee National Hospital, Clydebank, UK
| |
Collapse
|
3
|
Afghanyar Y, Joser S, Tecle J, Drees P, Dargel J, Rehbein P, Kutzner KP. The concept of a cementless isoelastic monoblock cup made of highly cross-linked polyethylene infused with vitamin E: radiological analyses of migration and wear using EBRA and clinical outcomes at mid-term follow-up. BMC Musculoskelet Disord 2021; 22:107. [PMID: 33485345 PMCID: PMC7827971 DOI: 10.1186/s12891-021-03981-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/02/2020] [Accepted: 01/17/2021] [Indexed: 11/10/2022] Open
Abstract
Background The newest generation of cementless titanium-coated, isoelastic monoblock cup with vitamin E-blended highly cross-linked polyethylene (HXLPE) was introduced to the market in 2009. The aim of the present study was to obtain mid-term follow-up data including migration and wear analyses. Methods This prospective study investigated 101 primary total hip arthroplasty (THA) cases in 96 patients treated at a single institution. Patients were allowed full weight-bearing on the first day postoperatively. Harris hip score (HHS) and pain and satisfication on a visual analogue scale (VAS) were assessed at a mean follow-up of 79.0 months. Migration and wear were assessed using Einzel-Bild-Roentgen-Analyse (EBRA) software. Radiological acetabular bone alterations and complications were documented. Results At mid-term follow-up (mean 79.0 months, range: 51.8–101.7), 81 cases with complete clinical and radiological data were analyzed. Utilisable EBRA measurements were obtained for 42 hips. The mean HHS was 91.1 (range 38.0–100.0), VAS satisfaction was 9.6 (range 6.0–10.0), VAS rest pain was 0.2 (range 0.0–4.0), and VAS load pain was 0.6 (range 0.0–9.0). Mean migration was 0.86 mm (range: 0.0–2.56) at 24 months and 1.34 mm (range: 0.09–3.14) at 5 years, and the mean annual migration rate was 0.22 (range: − 0.24–1.34). The mean total wear was 0.4 mm (range: 0.03–1.0), corresponding to a mean annual wear rate of 0.06 mm per year (range: 0.0–0.17). Radiographic analysis did not reveal any cases of osteolysis, and no revision surgeries had to be performed. Conclusions After using vitamin-E blended HXLPE in cementless isoelastic monoblock cups, there were no obvious signs of osteolysis or aseptic loosening occurred. No patients required revision surgery after mid-term follow-up. Cup migration and wear values were well below the benchmarks considered predictive for potential future failure. Trial registration The trial registration number on ClinicalTrials.gov: NCT04322916 (retrospectively registered at 26.03.2020). Supplementary Information The online version contains supplementary material available at 10.1186/s12891-021-03981-8.
Collapse
Affiliation(s)
- Yama Afghanyar
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany.
| | - Sebastian Joser
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Jonas Tecle
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Drees
- Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| | - Jens Dargel
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Philipp Rehbein
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany
| | - Karl Philipp Kutzner
- Department of Orthopaedic Surgery, St. Josefs Hospital Wiesbaden, Beethovenstr. 20, 65189, Wiesbaden, Germany.,Department of Orthopaedics and Traumatology, University Medical Centre of the Johannes Gutenberg-University of Mainz, Langenbeckstraße 1, 55131, Mainz, Germany
| |
Collapse
|
4
|
Anderl C, Mattiassich G, Ortmaier R, Steinmair M, Hochreiter J. Peri-acetabular bone remodelling after uncemented total hip arthroplasty with monoblock press-fit cups: an observational study. BMC Musculoskelet Disord 2020; 21:652. [PMID: 33023553 PMCID: PMC7539379 DOI: 10.1186/s12891-020-03675-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Accepted: 09/24/2020] [Indexed: 11/23/2022] Open
Abstract
Background Bone stock preservation in total hip replacement is essential to allow for later revisions in an increasingly younger and fitter index patient population. While contemporary modular press-fit acetabular cups lead to rigid fixation with equatorial stress and central osteolysis, more elastic fixation may cause different peri-acetabular bone remodelling. The purpose of this study was to investigate changes in peri-acetabular bone mineral density (BMD) in uncemented elastic fixation with monoblock press-fit cups. Methods This prospective observational study included 45 patients with monoblock cups. We evaluated peri-acetabular BMD using dual-energy X-ray absorptiometry and reported functional outcomes and complications. Results At a mean follow-up of 24.2 ± 2.2 months, we found that BMD stabilised in DeLee and Charnley zones I and III and recovered to baseline value in zone II. The mean Harris Hip Scores improved significantly from 56.9 ± 20.0 to 97.2 ± 4.0 (p < 0001). Other than one peri-operative dislocation, we saw no post-operative complications. Conclusions We found favourable adaptive bone changes with BMD stabilisation in the equatorial zones and recovery to pre-operative values in the central zone. Additionally, excellent clinical outcomes and few prosthesis-related complications strengthened the favourable results of monoblock acetabular cups. Trial registration Registration number DRKS00017076.
Collapse
Affiliation(s)
- Conrad Anderl
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria.
| | - Georg Mattiassich
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria.,Ludwig-Boltzmann Institute for Experimental and Clinical Traumatology, Donaueschingenstrasse 13, 1200, Vienna, Austria
| | - Reinhold Ortmaier
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria.,Research Unit of Orthopedic Sports Medicine and Injury Prevention, Institute for Sports Medicine, Alpine Medicine and Health Tourism (ISAG), UMIT, Eduard-Wallnöfer-Zentrum 1, 6060, Hall in Tirol, Austria
| | - Martin Steinmair
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria
| | - Josef Hochreiter
- Department of Orthopaedic Surgery, Ordensklinikum Barmherzige Schwestern, Vinzenz Gruppe, Center of Orthopaedic Excellence, Teaching Hospital of the Paracelsus Medical University Salzburg, Seilerstätte 4, 4020, Linz, Austria
| |
Collapse
|
5
|
Coupry A, Rony L, Ducellier F, Hubert L, Chappard D. Texture analysis of trabecular bone around RM-Pressfit cementless acetabulum in a series of 46 patients during a 5 year period. Orthop Traumatol Surg Res 2019; 105:1283-1287. [PMID: 31477444 DOI: 10.1016/j.otsr.2019.06.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/02/2019] [Revised: 05/27/2019] [Accepted: 06/06/2019] [Indexed: 02/02/2023]
Abstract
BACKGROUND Cementless total hip arthroplasty (THA) is a common procedure producing excellent clinical results. Their long-term survival is nevertheless burdened by loosening of the acetabular part caused by changes in the distribution of strains around the cup. In this context the RM-Pressfit® cup has been developed, resulting in a more harmonious distribution of the strains. HYPOTHESIS Texture analysis of X-ray films can evaluate the evolution of trabecular bone micro-architecture during the five years following THA with a RM-Pressfit® cup. MATERIAL AND METHOD A monocentric series of 46 hips was reviewed regularly within five years post- surgery. Radiographic evaluation of the operated hip was done on frontal digitized radiographs of the pelvis to follow evolution of bone micro-architecture in the #2 zone of De Lee and Charnley. Texture analysis using fractal algorithms was done at D0, 6 months, 1, 2 and 5 years post-THA. The fractal methods used included the skyscrapers and the dynamic blanket methods with 3 different structuring elements (a cross, a horizontal and a vertical vector). RESULTS The RM-Pressfit® caused significant changes in the distribution of strains around the acetabulum that preserved the bone volume over a 5-year period post-surgery. This corresponds to an improvement of the trabecular micro-architecture around the acetabular cups. CONCLUSION A statistically significant increase in the four fractal dimensions considered corresponded to an improved trabecular bone micro-architecture revealed by texture analysis, a non-invasive method that can be used on digitized X-ray images. LEVEL OF EVIDENCE IIIb, Case control study, retrospective design.
Collapse
Affiliation(s)
- Augustin Coupry
- Département de chirurgie osseuse, CHU-Angers, 49033 Angers, France
| | - Louis Rony
- Département de chirurgie osseuse, CHU-Angers, 49033 Angers, France; Groupe Etudes Remodelage Osseux et bioMatériaux, GEROM, EA-4658, SFR-4208, Univ-Angers, IRIS-IBS Institut de Biologie en Santé, CHU-Angers, 49933 Angers, France
| | | | - Laurent Hubert
- Département de chirurgie osseuse, CHU-Angers, 49033 Angers, France; Groupe Etudes Remodelage Osseux et bioMatériaux, GEROM, EA-4658, SFR-4208, Univ-Angers, IRIS-IBS Institut de Biologie en Santé, CHU-Angers, 49933 Angers, France
| | - Daniel Chappard
- Groupe Etudes Remodelage Osseux et bioMatériaux, GEROM, EA-4658, SFR-4208, Univ-Angers, IRIS-IBS Institut de Biologie en Santé, CHU-Angers, 49933 Angers, France.
| |
Collapse
|
6
|
Erivan R, Aubret S, Villatte G, Mulliez A, Descamps S, Boisgard S. Does using a polyethylene RM press-fit cup modify the preparation of the acetabulum and acetabular offset in primary hip arthroplasty? Orthop Traumatol Surg Res 2017; 103:669-674. [PMID: 28579018 DOI: 10.1016/j.otsr.2017.03.026] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/05/2017] [Revised: 03/23/2017] [Accepted: 03/29/2017] [Indexed: 02/02/2023]
Abstract
INTRODUCTION When performing total hip arthroplasty (THA), it is important to maintain the femoral and acetabular offsets to ensure good joint stability and to restore the function of the hip abductor muscles. In our practice, we mainly use a lateralized stem and hollow out the acetabulum to the quadrilateral plate to accommodate a press-fit polyethylene cup. However, the repercussions of this preparation method, which is driven by the cup's design, are not known. We carried out a retrospective study to assess: (1) the changes in the femoral and acetabular offset; (2) the height of the center of rotation; and (3) the repercussions on wear. HYPOTHESIS We hypothesized there would be no significant differences between the preoperative and postoperative femoral and acetabular offsets. PATIENTS AND METHODS We reviewed 88 primary THA cases performed with the RM Pressfit™ cup that had a minimum of 5 years' follow-up. A lateralized self-locking Muller-type cemented femoral stem was used in 92.0% of cases and a standard stem in 8.0%. Measurements were done on plain radiographs with MHP™ and Mesurim Pro™ software. The average follow-up was 6.5 years (5-8). RESULTS On average, the acetabular offset was reduced by 2.75mm±5.9 mm (range: -17.5 to +10.6 mm) (P<0.001) and the femoral offset was increased by 0.01mm±5.5 mm (range: -17.8 to +11.0 mm) (P=0.99). In terms of total offset, medialization of 2.74mm±7 mm (range: -17.7 to +18.2mm) was found (P=0.001). The acetabular center of rotation was on average 4.77mm±5.1 mm higher (P<0.001). The mean annual wear at the more recent follow-up (min.: 5 years) was 0.068mm (range: 0.01 to 0.25mm) per year. The wear was not impacted by having more than 5mm change in offset. DISCUSSION Measurements of acetabular offset revealed statistically significant medialization due to the type of implant used and the surgical technique. The anatomical technique consists of positioning the cup in subchondral bone without contacting the quadrilateral plate. This preserves bone stock, which may be useful later on if the cup is revised, particularly in younger patients. Conversely, the femoral offset did not change significantly, despite the use of lateralized stems in 92.0% of cases. We measured an annual wear rate of 0.068mm per year, which is lower than in other published studies, possibly because our patient population was older. LEVEL OF EVIDENCE IV, retrospective study.
Collapse
Affiliation(s)
- R Erivan
- CNRS, SIGMA Clermont, ICCF, université Clermont Auvergne, CHU de Clermont-Ferrand, 63000 Clermont-Ferrand, France.
| | - S Aubret
- Université Clermont Auvergne, CHU de Clermont-Ferrand, 63000 Clermont-Ferrand, France
| | - G Villatte
- CNRS, SIGMA Clermont, ICCF, université Clermont Auvergne, CHU de Clermont-Ferrand, 63000 Clermont-Ferrand, France
| | - A Mulliez
- Délégation à la recherche clinique et aux innovations (DRCI), CHU de Clermont-Ferrand, 63000 Clermont-Ferrand, France
| | - S Descamps
- CNRS, SIGMA Clermont, ICCF, université Clermont Auvergne, CHU de Clermont-Ferrand, 63000 Clermont-Ferrand, France
| | - S Boisgard
- CNRS, SIGMA Clermont, ICCF, université Clermont Auvergne, CHU de Clermont-Ferrand, 63000 Clermont-Ferrand, France
| |
Collapse
|
7
|
RM Pressfit® cup: good preliminary results at 5 to 8 years follow-up for 189 patients. Hip Int 2016; 26:386-91. [PMID: 27312329 DOI: 10.5301/hipint.5000359] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 01/11/2016] [Indexed: 02/04/2023]
Abstract
AIM The RM Classic® cup shows very good results. The RM Pressfit® cup has an equatorial pressfit; it is a monoblock implant without metalback. The aim of this study was to evaluate retrospectively the survival of this implant, monitoring patients for at least 5 years in all consecutive cases operated in our centre. METHODS Between February 2006 and December 2008, our department performed 189 consecutive nonselected primary total hip arthroplasties using the RM® Pressfit cup, and all of these were included in the study. The operative technique involved an anterolateral approach. The latest follow-up evaluation was performed at a minimum of 5 years after the index arthroplasty. RESULTS The mean follow-up was 6.5 years (5-8 years). We had preoperative information for 186 of the 189 patients. 102 patients were seen in consultation (54.0%), 46 (24.3%) patients were contacted by phone, 37 (19.6%) patients died, and 4 patients (2.1%) were lost for unknown reasons. Of the 189 arthroplasties, 6 (3.2%) required revision; 4 (2.1%) for infection, 1 (0.5%) for significant haematoma with persistent deglobulisation and 1 (0.5%) for periprosthetic calcification during the 5 to 8 years following the operation. No hip was revised because of aseptic loosening. The mean annual wear rate based on the last follow-up at 5 years minimum was 0.065 mm per year. We observed no migration, 1 femoral loosening and no acetabular loosening. CONCLUSIONS Our study finds a good survival rate which is compatible with the 94% at 20 years with RM Classic®. These results are suggestive but must be confirmed with long-term studies.
Collapse
|
8
|
Abstract
BACKGROUND Uncemented acetabular components have demonstrated low revision rates and high patient satisfaction but with concerns regarding increased costs compared with monoblock cups. Some newer lower-cost uncemented monoblock options have become available in the last decade, but limited data are available on their performance. QUESTIONS/PURPOSES (1) Does an uncemented, titanium-backed all-polyethylene acetabular cup provide reliable fixation? (2) What is the frequency and what are the causes for revision with this cup? METHODS Between 2004 and 2008, we elected to use an uncemented, titanium-backed all-polyethylene acetabular cup in older patients with limited physical demands. We performed 615 hip replacements in 550 patients with greater than 5 years of clinical and radiographic followup. When patients who were dead (80 hips in 75 patients), lost to followup (98 hips in 93 patients), or revised (three hips in three patients) were excluded, there were 434 hips in 379 patients for comparison of the postoperative and 5-year radiographs. Two observers not involved in the index surgical procedures (NH, HS) assessed radiographs for signs of migration or loosening. Some degree of early movement sometimes is seen before cup stabilization; however, to be conservative, we defined cups with greater than 3° of change of position (even if they subsequently stabilized) as potentially at risk and report them separately. Revision surgery, time from the index procedure, and the reason for revision were recorded from the New Zealand Joint Registry. RESULTS By 5 years there was a median change in inclination of 2° (range, 0°-13°; 95% confidence interval [CI], 2.0-2.4; p < 0.001) and 2° of anteversion (range, 0°-11°; 95% CI, 2.0-2.4; p < 0.001). Although at last followup all cups appeared to have stabilized with no radiolucent lines or medial migration, 22% of the cups (94 of 434) had moved more than 3° and so were deemed to be potentially at risk. There were 11 revision procedures (of 429 hips; 2.5%) of which six were for recurrent dislocation, four for femoral fracture, and one for femoral loosening to give an overall all-cause revision rate for all components of 0.25 per 100 component years (95% CI, 0.13-0.43). No revisions were performed for acetabular loosening. CONCLUSIONS The short- to medium-term results of this all-polyethylene monoblock cup demonstrated a low frequency of revision. However, 94 cups were identified as potentially at risk based on movement of > 3° before apparent stabilization. Although those patients seem to be doing well enough now, the current duration of followup may not be sufficient to know that these cups will be durable, because other ongrowth designs have demonstrated a high frequency of late failure after apparent early success. LEVEL OF EVIDENCE Level IV, therapeutic study.
Collapse
|
9
|
Qiu C, Wang L, Li D, Jin Z. The influence of metallic shell deformation on the contact mechanics of a ceramic-on-ceramic total hip arthroplasty. Proc Inst Mech Eng H 2015; 230:4-12. [PMID: 26511269 DOI: 10.1177/0954411915614514] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2015] [Accepted: 09/14/2015] [Indexed: 11/17/2022]
Abstract
Total hip arthroplasty of ceramic-on-ceramic bearing combinations is increasingly used clinically. The majority of these implants are used with cementless fixation that a metal-backing shell is press-fitted into the pelvic bone. This usually results in the deformation of the metallic shell, which may also influence the ceramic liner deformation and consequently the contact mechanics between the liner and the femoral head under loading. The explicit dynamic finite element method was applied to model the implantation of a cementless ceramic-on-ceramic with a titanium shell and subsequently to investigate the effect of the metallic shell deformation on the contact mechanics. A total of three impacts were found to be necessary to seat the titanium alloy shell into the pelvic bone cavity with a 1 mm diameter interference and a 1.3 kg impactor at 4500 mm s(-1) velocity. The maximum deformation of the metallic shell was found to be 160 µm in the antero-superior and postero-inferior direction and 97 µm in the antero-inferior and postero-superior direction after the press-fit. The corresponding values were slightly reduced to 67 and 45 µm after the ceramic liner was inserted and then modified to 74 and 43 µm under loading, respectively. The maximum deformation and the maximum principal stress of the ceramic liner were 31 µm and 144 MPa (tensile stress), respectively, after it was inserted into the shell and further increased to 52 µm and 245 MPa under loading. This research highlights the importance of the press-fit of the metallic shell on the contact mechanics of the ceramic liner for ceramic-on-ceramic total hip arthroplasties and potential clinical performances.
Collapse
Affiliation(s)
- Changdong Qiu
- State Key Laboratory for Manufacturing Systems Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Ling Wang
- State Key Laboratory for Manufacturing Systems Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Dichen Li
- State Key Laboratory for Manufacturing Systems Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China
| | - Zhongmin Jin
- State Key Laboratory for Manufacturing Systems Engineering, School of Mechanical Engineering, Xi'an Jiaotong University, Xi'an, China Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, UK
| |
Collapse
|