1
|
Khan S, Tsai PY, Qi B, Chen C, Jokerst JV. Performance Evaluation of a Miniaturized, Toothbrush-Shaped Ultrasound Transducer for Periodontal Imaging. ACS Sens 2025. [PMID: 40420333 DOI: 10.1021/acssensors.5c00521] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/28/2025]
Abstract
A miniature, high-frequency ultrasound transducer could have major value in dentistry and periodontal care. Still, most current ultrasound transducers use large form factors, which limit access to molars and premolars. This paper reports a compact side-facing, toothbrush-shaped ultrasound transducer with a portable handle for real-time imaging of anatomical structures. The 128-element, high-frequency (40 MHz) response of the transducer was utilized to characterize the axial and lateral resolution at 2-16 mm depths, as well as the impact of angulation. The mean axial and lateral resolutions were 49 ± 15 μm and 149 ± 21 μm, respectively. The impact of angulation on imaging quality was evaluated. An acceptable angular window of -15° to +20° in the roll and pitch axes was found to produce correct anatomical information. Angulation in the yaw axis loses control over the reference plane. The transducer soft tissue-related measurements (gingival thickness and gingival height) correlated with the gold-standard clinical measurements. The correlation coefficients, r = 0.7243 (p = 0.0001) for gingival thickness and 0.7886 (p < 0.0001) for gingival height, show a strong correlation with the clinical method. The Bland-Altman plot compared ultrasound imaging and manual periodontal probe measurements indicated a bias of -0.002 mm and -0.0263 mm, respectively, for gingival thickness and height, with a 95% limit of agreement. The miniaturized high-frequency transducer offers optimal adaptation to the tooth surface with a wide range of working axes, providing high-resolution and detailed ultrasound images for real-time scans of the periodontium.
Collapse
Affiliation(s)
- Suhel Khan
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, La Jolla, San Diego, California 92093, United States
| | - Pei Yun Tsai
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, La Jolla, San Diego, California 92093, United States
| | - Baiyan Qi
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, La Jolla, San Diego, California 92093, United States
| | - Casey Chen
- Herman Ostrow School of Dentistry, University of Southern California, 925 West 34th Street, Los Angeles, California 90089, United States
| | - Jesse V Jokerst
- Aiiso Yufeng Li Family Department of Chemical and Nano Engineering, University of California, La Jolla, San Diego, California 92093, United States
- Material Science and Engineering Program, University of California, La Jolla, San Diego, California 92093, United States
- Radiology Department, University of California, La Jolla, San Diego, California 92093, United States
| |
Collapse
|
2
|
Hacker L, Joseph J, Lilaj L, Manohar S, Ivory AM, Tao R, Bohndiek SE, Members of IPASC. Tutorial on phantoms for photoacoustic imaging applications. JOURNAL OF BIOMEDICAL OPTICS 2024; 29:080801. [PMID: 39143981 PMCID: PMC11324153 DOI: 10.1117/1.jbo.29.8.080801] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/12/2024] [Revised: 05/28/2024] [Accepted: 05/29/2024] [Indexed: 08/16/2024]
Abstract
Significance Photoacoustic imaging (PAI) is an emerging technology that holds high promise in a wide range of clinical applications, but standardized methods for system testing are lacking, impeding objective device performance evaluation, calibration, and inter-device comparisons. To address this shortfall, this tutorial offers readers structured guidance in developing tissue-mimicking phantoms for photoacoustic applications with potential extensions to certain acoustic and optical imaging applications. Aim The tutorial review aims to summarize recommendations on phantom development for PAI applications to harmonize efforts in standardization and system calibration in the field. Approach The International Photoacoustic Standardization Consortium has conducted a consensus exercise to define recommendations for the development of tissue-mimicking phantoms in PAI. Results Recommendations on phantom development are summarized in seven defined steps, expanding from (1) general understanding of the imaging modality, definition of (2) relevant terminology and parameters and (3) phantom purposes, recommendation of (4) basic material properties, (5) material characterization methods, and (6) phantom design to (7) reproducibility efforts. Conclusions The tutorial offers a comprehensive framework for the development of tissue-mimicking phantoms in PAI to streamline efforts in system testing and push forward the advancement and translation of the technology.
Collapse
Affiliation(s)
- Lina Hacker
- University of Oxford, Department of Oncology, Oxford, United Kingdom
| | - James Joseph
- University of Dundee, School of Science and Engineering, United Kingdom
- University of Dundee, Centre for Medical Engineering and Technology, Dundee, United Kingdom
| | | | - Srirang Manohar
- University of Twente, Tech Med Centre, Multi-Modality Medical Imaging, Enschede, The Netherlands
| | - Aoife M. Ivory
- St. Vincent’s Private Hospital, Department of Medical Physics, Dublin, Ireland
| | - Ran Tao
- University of Cambridge, Department of Physics, Cambridge, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom
| | - Sarah E. Bohndiek
- University of Cambridge, Department of Physics, Cambridge, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom
| | - Members of IPASC
- University of Oxford, Department of Oncology, Oxford, United Kingdom
- University of Dundee, School of Science and Engineering, United Kingdom
- University of Dundee, Centre for Medical Engineering and Technology, Dundee, United Kingdom
- iThera Medical GmbH, Munich, Germany
- University of Twente, Tech Med Centre, Multi-Modality Medical Imaging, Enschede, The Netherlands
- St. Vincent’s Private Hospital, Department of Medical Physics, Dublin, Ireland
- University of Cambridge, Department of Physics, Cambridge, United Kingdom
- University of Cambridge, Cancer Research UK Cambridge Institute, Cambridge, United Kingdom
| |
Collapse
|
3
|
Li Y, Gröhl J, Haney B, Caranovic M, Lorenz-Meyer E, Papatheodorou N, Kempf J, Regensburger AP, Nedoschill E, Buehler A, Siebenlist G, Lang W, Uder M, Neurath MF, Waldner M, Knieling F, Rother U. Teachability of multispectral optoacoustic tomography. JOURNAL OF BIOPHOTONICS 2024; 17:e202400106. [PMID: 38719459 DOI: 10.1002/jbio.202400106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2024] [Revised: 04/12/2024] [Accepted: 04/19/2024] [Indexed: 07/13/2024]
Abstract
To date, the appropriate training required for the reproducible operation of multispectral optoacoustic tomography (MSOT) is poorly discussed. Therefore, the aim of this study was to assess the teachability of MSOT imaging. Five operators (two experienced and three inexperienced) performed repositioning imaging experiments. The inexperienced received the following introductions: personal supervision, video meeting, or printed introduction. The task was to image the exact same position on the calf muscle for seven times on five volunteers in two rounds of investigations. In the first session, operators used ultrasound guidance during measurements while using only photoacoustic data in the second session. The performance comparison was carried out with full-reference image quality measures to quantitatively assess the difference between repeated scans. The study demonstrates that given a personal supervision and hybrid ultrasound real-time imaging in MSOT measurements, inexperienced operators are able to achieve the same level as experienced operators in terms of repositioning accuracy.
Collapse
Affiliation(s)
- Yi Li
- Department of Vascular Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Janek Gröhl
- Cancer Research UK Cambridge Institute, University of Cambridge, Cambridge, UK
- Department of Physics, University of Cambridge, Cambridge, UK
| | - Briain Haney
- Department of Vascular Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Milenko Caranovic
- Department of Vascular Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Eva Lorenz-Meyer
- Department of Vascular Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Faculty of Medicine, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Nikolaos Papatheodorou
- Department of Vascular Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Julius Kempf
- Department of Vascular Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Adrian P Regensburger
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Emmanuel Nedoschill
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Adrian Buehler
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Gregor Siebenlist
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Werner Lang
- Department of Vascular Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Michael Uder
- Institute of Radiology, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Markus F Neurath
- Department of Medicine 1, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Deutsches Zentrum für Immuntherapie (DZI), University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Maximilian Waldner
- Department of Medicine 1, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Deutsches Zentrum für Immuntherapie (DZI), University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
- Erlangen Graduate School in Advanced Optical Technologies (SAOT), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
| | - Ferdinand Knieling
- Department of Pediatrics and Adolescent Medicine, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Ulrich Rother
- Department of Vascular Surgery, University Hospital Erlangen, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| |
Collapse
|
4
|
Nie S, Yin G, Li P, Guo J. Optimization on artifacts in photoacoustic images based on spectrum analyses and signal extraction. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2024; 156:503-510. [PMID: 39013038 DOI: 10.1121/10.0027934] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2024] [Accepted: 06/28/2024] [Indexed: 07/18/2024]
Abstract
Photoacoustic (PA) imaging is a promising technology for functional imaging of biological tissues, offering optical contrast and acoustic penetration depth. However, the presence of signal aliasing from multiple PA sources within the same imaging object can introduce artifacts and significantly impact the quality of the PA tomographic images. In this study, an optimized method is proposed to suppress these artifacts and enhance image quality effectively. By leveraging signal time-frequency spectrum, signals from each PA source can be extracted. Subsequently, the images are reconstructed using these extracted signals and fused together to obtain an optimized image. To verify this proposed method, PA imaging experiments were conducted on two phantoms and two in vitro samples and the distribution relative error and root mean square error of the images obtained through conventional and optimized methods were calculated. The results demonstrate that the proposed method successfully suppresses the artifacts and substantially improves the image quality.
Collapse
Affiliation(s)
- Shibo Nie
- Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710119, China
| | - Guanjun Yin
- Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710119, China
| | - Pan Li
- School of Physics and Electrical Engineering, Weinan Normal University, Wei'Nan 714099, China
| | - Jianzhong Guo
- Key Laboratory of Ultrasound of Shaanxi Province, School of Physics and Information Technology, Shaanxi Normal University, Xi'an 710119, China
| |
Collapse
|
5
|
Munisso MC, Liu C, Yamamoto G, Kosaka T, Tsuge I, Saito S, Morimoto N. PreFlap: From Photoacoustic Tomography Images to Vascular Mapping Sheets for Improved Preoperative Flap Evaluation. IEEE Trans Biomed Eng 2024; 71:139-149. [PMID: 37432833 DOI: 10.1109/tbme.2023.3293812] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/13/2023]
Abstract
OBJECTIVE Advancements in technology have improved image acquisition and processing in the field of medical imaging, giving medical doctors the tools to implement effective medical care. In plastic surgery, despite advances in anatomical knowledge and technology, problems in preoperative planning for flap surgery remain. METHODS In this study, we propose a new protocol to analyze three-dimensional (3D) Photoacoustic tomography images and generate two-dimensional (2D) mapping sheets that can help surgeons identify perforators and the perfusion territory during preoperative planning. The core of this protocol is PreFlap, a new algorithm that converts 3D photoacoustic tomography images into 2D vascular mapping images. CONCLUSION Experimental results demonstrate that PreFlap can improve preoperative flap evaluation, thus can greatly saving surgeons' time and improving surgical outcomes.
Collapse
|
6
|
Grasso V, Raymond JL, Willumeit-Römer R, Joseph J, Jose J. Development of a morphologically realistic mouse phantom for pre-clinical photoacoustic imaging. Med Phys 2023; 50:5757-5771. [PMID: 37535898 DOI: 10.1002/mp.16651] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2023] [Accepted: 07/10/2023] [Indexed: 08/05/2023] Open
Abstract
BACKGROUND Characterizations based on anatomically realistic phantoms are highly effective to perform accurate technical validation of imaging systems. Specifically for photoacoustic imaging (PAI), although a variety of phantom models with simplified geometries are reported, an unmet need still exists to establish morphologically realistic heterogeneous pre-clinical phantoms. So the development of a mouse-mimicking phantom can reduce the use of animals for the validation and standardization studies of pre-clinical PAI systems and thus eventually translate the PAI technology to clinical research. PURPOSE Here we designed, developed, and fabricated a stable phantom that mimics the detailed morphology of a mouse, to be used as a realistic tool for PAI. METHODS The mouse phantom, has been designed by using a combination of image modeling and 3D-printing techniques. As a tissue-mimicking material, we have used copolymer-in-oil-based material that was recently proposed by the International Photoacoustic Standardization Consortium (IPASC). In particular, the anatomically realistic phantom has been modeled by using the real atlas of a mouse as a reference. The mouse phantom includes a 3D-printed skeleton and the main abdominal organs such as the liver, spleen, and kidneys obtained by using doped copolymer-in-oil material with 3D-printed molds. In addition, the acoustic and optical properties of the tissue-mimicking material and the long-term stability have been broadly characterized. RESULTS Furthermore, our studies showed that the phantom is durable and stable for more than 200 days, under normal storage and repeated use. Fabrication protocol is easy to reproduce. As a result, the proposed morphologically realistic mouse phantom offers durability, material compatibility, and an unprecedented realistic resemblance to the actual rodents' anatomy in PAI. CONCLUSION This durable morphologically realistic mouse phantom would minimize the animal experiments in compliance with the 3R principle of Replacement, Reduction, and Refinement. To our knowledge, this is the first time an anatomically realistic heterogeneous mouse phantom has been proposed for PAI in pre-clinical animal imaging and tested its durability over 200 days.
Collapse
Affiliation(s)
- Valeria Grasso
- FUJIFILM VisualSonics, Amsterdam, The Netherlands
- Institute for Materials Science, Faculty of Engineering, Christian-Albrecht University of Kiel, Kiel, Germany
| | - Jason L Raymond
- Department of Engineering Science, University of Oxford, Oxford, UK
| | - Regine Willumeit-Römer
- Institute for Materials Science, Faculty of Engineering, Christian-Albrecht University of Kiel, Kiel, Germany
- Institute of Materials Research, Division Metallic Biomaterials, Helmholtz-Zentrum Hereon GmbH, Geesthacht, Germany
| | - James Joseph
- School of Science and Engineering, University of Dundee, Dundee, UK
- Centre for Medical Engineering and Technology, University of Dundee, Dundee, UK
| | - Jithin Jose
- FUJIFILM VisualSonics, Amsterdam, The Netherlands
| |
Collapse
|
7
|
Christie LB, Zheng W, Johnson W, Marecki EK, Heidrich J, Xia J, Oh KW. Review of imaging test phantoms. JOURNAL OF BIOMEDICAL OPTICS 2023; 28:080903. [PMID: 37614568 PMCID: PMC10442662 DOI: 10.1117/1.jbo.28.8.080903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 07/31/2023] [Accepted: 08/04/2023] [Indexed: 08/25/2023]
Abstract
Significance Photoacoustic tomography has emerged as a prominent medical imaging technique that leverages its hybrid nature to provide deep penetration, high resolution, and exceptional optical contrast with notable applications in early cancer detection, functional brain imaging, drug delivery monitoring, and guiding interventional procedures. Test phantoms are pivotal in accelerating technology development and commercialization, specifically in photoacoustic (PA) imaging, and can be optimized to achieve significant advancements in PA imaging capabilities. Aim The analysis of material properties, structural characteristics, and manufacturing methodologies of test phantoms from existing imaging technologies provides valuable insights into their applicability to PA imaging. This investigation enables a deeper understanding of how phantoms can be effectively employed in the context of PA imaging. Approach Three primary categories of test phantoms (simple, intermediate, and advanced) have been developed to differentiate complexity and manufacturing requirements. In addition, four sub-categories (tube/channel, block, test target, and naturally occurring phantoms) have been identified to encompass the structural variations within these categories, resulting in a comprehensive classification system for test phantoms. Results Based on a thorough examination of literature and studies on phantoms in various imaging modalities, proposals have been put forth for the development of multiple PA-capable phantoms, encompassing considerations related to the material composition, structural design, and specific applications within each sub-category. Conclusions The advancement of novel and sophisticated test phantoms within each sub-category is poised to foster substantial progress in both the commercialization and development of PA imaging. Moreover, the continued refinement of test phantoms will enable the exploration of new applications and use cases for PA imaging.
Collapse
Affiliation(s)
- Liam B. Christie
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - Wenhan Zheng
- State University of New York at Buffalo, Optical and Ultrasonic Imaging Laboratory, Biomedical Engineering, Buffalo, New York, United States
| | - William Johnson
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - Eric K. Marecki
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - James Heidrich
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| | - Jun Xia
- State University of New York at Buffalo, Optical and Ultrasonic Imaging Laboratory, Biomedical Engineering, Buffalo, New York, United States
| | - Kwang W. Oh
- State University of New York at Buffalo, Sensors and MicroActuators Learning Lab, Electrical Engineering, Buffalo, New York, United States
| |
Collapse
|
8
|
Yang T, Jin Y, Neogi A. Acoustic Attenuation and Dispersion in Fatty Tissues and Tissue Phantoms Influencing Ultrasound Biomedical Imaging. ACS OMEGA 2023; 8:1319-1330. [PMID: 36643513 PMCID: PMC9835773 DOI: 10.1021/acsomega.2c06750] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 12/13/2022] [Indexed: 06/17/2023]
Abstract
The development of ultrasonic imaging techniques is optimized using artificial tissue phantoms before the practical applications. However, due to the strong attenuation and dispersion, accumulated fatty tissues can significantly impact the resolution and even feasibility of certain ultrasonic imaging modalities. An appropriate characterization of the acoustic properties on fatty phantoms can help the community to overcome the limitations. Some of the existing methods heavily overestimate attenuation coefficients by including the reflection loss and dispersion effects. Hence, in this study, we use numerical simulation-based comparison between two major attenuation measurement configurations. We further pointed out the pulse dispersion in viscoelastic tissue phantoms by simulations, which barely attracted attention in the existing studies. Using the selected attenuation and dispersion testing methods that were selected from the numerical simulation, we experimentally characterized the acoustic properties of common fatty tissue phantoms and compared the acoustic properties with the natural porcine fatty tissue samples. Furthermore, we selected one of the tissue phantoms to construct ultrasound imaging samples with some biomasses. With the known attenuation and dispersion of the tissue phantom, we showed the clarity enhancement of ultrasound imaging by signal post-processing to weaken the attenuation and dispersion effects.
Collapse
Affiliation(s)
- Teng Yang
- Department
of Physics, University of North Texas, Denton, Texas76203, United States
- Department
of Materials Science and Engineering,University
of North Texas, Denton, Texas76207, United States
| | - Yuqi Jin
- Department
of Physics, University of North Texas, Denton, Texas76203, United States
| | - Arup Neogi
- Department
of Physics, University of North Texas, Denton, Texas76203, United States
- Institute
of Fundamental and Frontier Sciences, University
of Electronic Science and Technology of China, Chengdu611731, P. R. China
| |
Collapse
|
9
|
Qi B, Hariri A, Khazaeinezhad R, Fu L, Li Y, Jin Z, Yim W, He T, Cheng Y, Zhou J, Jokerst JV. A miniaturized ultrasound transducer for monitoring full-mouth oral health: a preliminary study. Dentomaxillofac Radiol 2023; 52:20220220. [PMID: 36075610 PMCID: PMC9793456 DOI: 10.1259/dmfr.20220220] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 08/11/2022] [Accepted: 08/15/2022] [Indexed: 01/11/2023] Open
Abstract
OBJECTIVE To customize a miniaturized ultrasound transducer to access full-mouth B-mode, color Doppler, and spectral Doppler imaging for monitoring oral health. METHODS A customized periodontal ultrasound transducer SS-19-128 (19 MHz, 128 channels) 1.8-cm wide and 1-cm thick was developed and connected to a data acquisition (DAQ) system. B-mode, color Doppler, and spectral Doppler data could all be collected with SS-19-128. The imaging resolution and penetration capacity of SS-19-128 were characterized on phantoms. The gingival thickness was measured on 11 swine teeth by SS-19-128 for comparison with conventional transgingival probing via Bland-Altman analysis and Pearson correlation. Five human subjects were then recruited to demonstrate B-mode and Doppler imaging by SS-19-128. RESULTS The axial and lateral spatial resolution at 5.5 mm depth is 102.1 µm and 142.9 µm, respectively. The penetration depth in a tissue-mimicking phantom is over 30 mm. In vivo B-mode imaging of all 28 teeth was demonstrated on one human subject, and imaging of tooth #18 was accessed on five human subjects. Gingival thickness measurement compared with transgingival probing showed a bias of -0.015 mm and SD of 0.031 mm, and a r = 0.9235 (p < 0.0001) correlation. In vivo color and spectral Doppler imaging of the supraperiosteal artery in human gingiva was performed to generate hemodynamic information. CONCLUSIONS The small size of SS-19-128 offers important advantages over existing ultrasound technology-more specifically, whole-mouth scanning/charting reminiscent of radiography. This is nearly a two-fold increase in the number of teeth that can be assessed versus conventional transducers.
Collapse
Affiliation(s)
- Baiyan Qi
- Materials Science and Engineering Program University of California San Diego, La Jolla, California, USA
| | - Ali Hariri
- StyloSonic LLC, San Diego, United States
| | | | - Lei Fu
- Department of Nanoengineering, University of California San Diego, La Jolla, California, USA
| | - Yi Li
- Department of Nanoengineering, University of California San Diego, La Jolla, California, USA
| | - Zhicheng Jin
- Department of Nanoengineering, University of California San Diego, La Jolla, California, USA
| | - Wonjun Yim
- Materials Science and Engineering Program University of California San Diego, La Jolla, California, USA
| | - Tengyu He
- Materials Science and Engineering Program University of California San Diego, La Jolla, California, USA
| | - Yong Cheng
- Department of Nanoengineering, University of California San Diego, La Jolla, California, USA
| | - Jiajing Zhou
- Department of Nanoengineering, University of California San Diego, La Jolla, California, USA
| | | |
Collapse
|