1
|
Yang QM, Zhang C, Zhang YY, Liu CN. Perspective in diagnostic accuracy of prenatal ultrasound and MRI for placenta accreta. J Matern Fetal Neonatal Med 2025; 38:2463401. [PMID: 39988362 DOI: 10.1080/14767058.2025.2463401] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2024] [Accepted: 01/28/2025] [Indexed: 02/25/2025]
Abstract
PURPOSE Placenta accreta (PA) significantly increases the risk of life-threatening maternal outcomes, and its rising prevalence, driven by the increase in cesarean deliveries, underscores the need for precise diagnostic tools to improve clinical management and outcomes. This study aims to evaluate the advanced diagnostic capabilities of prenatal ultrasound and magnetic resonance imaging (MRI) in the detection of PA, a severe obstetric complication characterized by abnormal adherence of the placenta to the myometrium. MATERIALS AND METHODS The study utilized a review of current literature and clinical studies to assess the diagnostic accuracy and clinical utility of ultrasound and MRI in identifying PA. Both imaging modalities were evaluated for their ability to assess the depth and extent of placental invasion, as well as their complementary roles in prenatal diagnosis. The experimental system included detailed imaging protocols for ultrasound and MRI, focusing on placental and uterine structures, and their application in real-world clinical settings. RESULTS The findings demonstrate that ultrasound and MRI are highly effective in diagnosing PA, with each modality offering unique advantages. Ultrasound is widely accessible and serves as the first-line diagnostic tool, providing detailed visualization of placental adherence and vascular patterns. MRI, on the other hand, offers superior soft tissue contrast and is particularly valuable in complex cases or when ultrasound findings are inconclusive. Together, these imaging techniques enable accurate evaluation of placental invasion, facilitating timely and targeted prenatal interventions. The study also highlights the potential for improved maternal and fetal outcomes through early diagnosis and optimized pregnancy management. CONCLUSIONS Prenatal ultrasound and MRI are indispensable tools in the diagnosis and management of placenta accreta, offering complementary insights that enhance diagnostic precision. Their combined use allows for detailed assessment of placental and uterine structures, guiding clinical decision-making and improving outcomes for both mothers and infants. Future advancements in imaging technology and research hold promise for further enhancing diagnostic accuracy and expanding clinical applications, ultimately contributing to safer and more effective care for patients with PA.
Collapse
Affiliation(s)
- Qiu-Min Yang
- Department of Ultrasound, Baoji Second Traditional Chinese Medicine Hospital, Baoji, China
| | - Chu Zhang
- Department of Ultrasound, Baoji Second Traditional Chinese Medicine Hospital, Baoji, China
| | - Yun-Yun Zhang
- Department of Ultrasound, Yuyang District People's Hospital, Yulin, China
| | - Cai-Ning Liu
- Department of Ultrasound, Yuyang District People's Hospital, Yulin, China
| |
Collapse
|
2
|
Turan OM, Bozkurt S, Turan S. Imaging of the Placenta. Clin Obstet Gynecol 2025; 68:72-85. [PMID: 39846881 DOI: 10.1097/grf.0000000000000905] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2025]
Abstract
Placental imaging is crucial in prenatal care, offering insights into both normal and abnormal pregnancies. Traditional methods like grayscale ultrasound and magnetic resonance imaging evaluate placental anatomy, whereas Doppler ultrasound is used for functional assessment. Recent advancements include functional magnetic resonance imaging and advanced Doppler software for demonstrating placental density and visualizing spiral arteries. B-flow and spatio-temporal image correlation are pivotal, sensitive tools for quantifying spiral artery distensibility and volume flow in early pregnancy. These techniques enhance our understanding of placental vascular architecture and promise early diagnosis and intervention for pregnancies at risk. This paper emphasizes the importance of advanced imaging in prenatal care.
Collapse
Affiliation(s)
- Ozhan M Turan
- Department of Obstetrics, Gynecology and Reproductive Sciences, School of Medicine, University of Maryland, College Park, Maryland
| | | | | |
Collapse
|
3
|
Chen YH, Chang YC, Wu WJ, Chen M, Yen CC, Lan YW, Cheng HC, Chen CM. Kefir peptides mitigate L-NAME-induced preeclampsia in rats through modulating hypertension and endothelial dysfunction. Biomed Pharmacother 2024; 180:117592. [PMID: 39490048 DOI: 10.1016/j.biopha.2024.117592] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 10/09/2024] [Accepted: 10/21/2024] [Indexed: 11/05/2024] Open
Abstract
AIM Preeclampsia is a complex and serious pregnancy disorder that leads to maternal and neonatal mortality worldwide. Kefir peptides (KPs), derived from various prebiotic fermentations in whole milk by kefir grains, were investigated for their potential therapeutic effects. In this study, we used the L-NAME in drinking water to induce a preeclampsia-like condition in spontaneous hypertension stroke-prone (SHRSP) pregnant rats. MAIN METHODS The rats were assigned to five groups: the normal group (WKY rats), the untreated group (SHRSP rat control pregnant), the L-NAME/Mock group (SHRSP rats fed with L-NAME water), the L-NAME/KPs-LD group (SHRSP rats fed with L-NAME water and low-dose KPs diets), and the L-NAME/KPs-HD group (SHRSP rats fed with L-NAME water and high-dose KPs diets) for a 20-day experiment. Chorioallantois membrane (CAM) assay was applied for ex vivo angiogenesis study of KPs treatment. KEY FINDINGS Data showed that rats in the L-NAME group developed severe hypertension, proteinuria, placental damage, and embryo resorption. Pre-administration of KPs significantly reduced hypertension, proteinuria, improved generalized endothelial dysfunction, and decreased levels of anti-HIF-1α, sFLT1, anti-TNF-α, and IL-6 in the placenta of SHRSP rats. In ex vivo CAM study, L-NAME administration in chicken embryos resulted in lower vessel density and hemorrhage; however, angiogenesis was observed after KPs-HD treatment. SIGNIFICANCE The results indicate that kefir peptides improve renal lesions, prevent renal parenchyma damage, and balance endothelial and angiogenic dysfunction in both maternal and fetal sites in L-NAME-induced SHRSP pregnant rats.
Collapse
Affiliation(s)
- Yu-Hsuan Chen
- Department of Life Sciences, Doctoral Program in Translational Medicine, National Chung Hsing University, Taichung 402, Taiwan.
| | - Yo-Cheng Chang
- Department of Life Sciences, Doctoral Program in Translational Medicine, National Chung Hsing University, Taichung 402, Taiwan.
| | - Wan-Ju Wu
- Department of Life Sciences, Doctoral Program in Translational Medicine, National Chung Hsing University, Taichung 402, Taiwan; Department of Obstetrics and Gynecology, Changhua Christian Hospital, Changhua 50006, Taiwan.
| | - Min Chen
- Department of Obstetrics and Gynecology, Changhua Christian Hospital, Changhua 50006, Taiwan; Department of Genomic Medicine, Changhua Christian Hospital, Changhua 50046, Taiwan.
| | - Chih-Ching Yen
- Department of Internal Medicine, China Medical University Hospital, China Medical University, Taichung 404, Taiwan.
| | - Ying-Wei Lan
- Department of Life Sciences, Doctoral Program in Translational Medicine, National Chung Hsing University, Taichung 402, Taiwan; Phoenix Children's Health Research Institute, Department of Child Health, University of Arizona College of Medicine, Phoenix 85004, USA.
| | - Hsu-Chen Cheng
- Department of Life Sciences, Doctoral Program in Translational Medicine, National Chung Hsing University, Taichung 402, Taiwan; The iEGG and Animal Biotechnology Center, and Rong Hsing Research Center for Translational Medicine, National Chung Hsing University, Taichung 402, Taiwan.
| | - Chuan-Mu Chen
- Department of Life Sciences, Doctoral Program in Translational Medicine, National Chung Hsing University, Taichung 402, Taiwan; The iEGG and Animal Biotechnology Center, and Rong Hsing Research Center for Translational Medicine, National Chung Hsing University, Taichung 402, Taiwan; Center for General Educational, National Quemoy University, Kinmen 892, Taiwan.
| |
Collapse
|
4
|
Belak U, Pinter B, Ban Frangež H, Velikonja M, Korošec S. Pathology of the Placenta in Singletons after Assisted Reproductive Technology Compared to Singletons after Spontaneous Conception: A Systematic Review. Fetal Pediatr Pathol 2022; 42:438-449. [PMID: 36580043 DOI: 10.1080/15513815.2022.2157228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022]
Abstract
Background: We reviewed the literature comparing the pathological characteristics of singleton births conceived after assisted reproductive technology (ART) with those after spontaneous conception. Methods: We reviewed PubMed, EMBASE, Ovid MEDLINE, Google Scopus, Scholar, Cochrane Central Register of Controlled Trials and the Web of Science for the previous 10 years, up to November 2022. Results: Four eligible studies included 3445 placentas, 806 after ART (IVF/ICSI). Placentas after ART differed in frequency of retroplacental and marginal hematomas (p = 0.04), increased thickness (p = 0.02), higher overall occurrences of vascular and anatomical pathology (p < 0.001) and more frequent marginal (p = 0.001) and membranous (p = 0.02) umbilical cord insertion than placentas from non-ART pregnancies. Conclusion: Further research is needed to determine the extent to which these placental changes in ART pregnancies alter its function and pregnancy outcome.
Collapse
Affiliation(s)
- Urška Belak
- Department of Gyneacology and Obstetrics, General Hospital Celje, Celje, Slovenia.,Faculty of medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Bojana Pinter
- Faculty of medicine, University of Ljubljana, Ljubljana, Slovenia.,Department of Human Reproduction, Division of Obstetrics and Gyneacology, University Medical Centre Ljubljana, Ljubljana, Slovenia
| | - Helena Ban Frangež
- Faculty of medicine, University of Ljubljana, Ljubljana, Slovenia.,Department of Human Reproduction, Division of Obstetrics and Gyneacology, University Medical Centre Ljubljana, Ljubljana, Slovenia
| | - Mojca Velikonja
- Department of Pathology, Faculty of medicine, University of Ljubljana, Ljubljana, Slovenia
| | - Sara Korošec
- Faculty of medicine, University of Ljubljana, Ljubljana, Slovenia.,Department of Human Reproduction, Division of Obstetrics and Gyneacology, University Medical Centre Ljubljana, Ljubljana, Slovenia
| |
Collapse
|
5
|
Santana EFM, Castello RG, Rizzo G, Grisolia G, Júnior EA, Werner H, Lituania M, Tonni G. Placental and Umbilical Cord Anomalies Diagnosed by Two- and Three-Dimensional Ultrasound. Diagnostics (Basel) 2022; 12:2810. [PMID: 36428871 PMCID: PMC9689386 DOI: 10.3390/diagnostics12112810] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2022] [Revised: 09/27/2022] [Accepted: 10/01/2022] [Indexed: 11/18/2022] Open
Abstract
The aim of this review is to present a wide spectrum of placental and umbilical cord pathologies affecting the pregnancy. Placental and umbilical cord anomalies are highly associated with high-risk pregnancies and may jeopardize fetal well-being in utero as well as causing a predisposition towards poor perinatal outcome with increased fetal and neonatal mortality and morbidity. The permanent, computerized perinatology databases of different international centers have been searched and investigated to fulfil the aim of this manuscript. An extended gallery of prenatal imaging with autopsy correlation in specific cases will help to provide readers with a useful iconographic tool and will assist with the understanding and definition of this critical obstetrical and perinatological issue.
Collapse
Affiliation(s)
| | | | - Giuseppe Rizzo
- Department of Obstetrics and Gynecology, Policlinic Hospital, Tot Vergata Foundation, Tor Vergata University, 00133 Rome, Italy
| | - Gianpaolo Grisolia
- Department of Obstetrics and Gynecology, Carlo Poma Hospital, 46100 ASST Mantua, Italy
| | - Edward Araujo Júnior
- Department of Obstetrics, Paulista School of Medicine—Federal University of Sao Paulo (EPM-UNIFESP), Sao Paulo-SP 04021-001, Brazil
- Medical Course, Municipal University of Sao Caetano do Sul (UCS), Bela Vista Campus, Sao Paulo-SP 09550-051, Brazil
| | - Heron Werner
- Centro Diagnostico Por Imagem, Rio de Janeiro 24070-035, Brazil
| | - Mario Lituania
- Preconceptional and Prenatal Pathophysiology, Department of Obstetrics and Gynecology, E.O. Ospedali Galliera, 16128 Genoa, Italy
| | - Gabriele Tonni
- Department of Obstetrics and Neonatology, and Researcher, Istituto di Ricovero e Cura a Carattere Scientifico (IRCCS/AUSL), 42122 Reggio Emilia, Italy;
| |
Collapse
|
6
|
Sotiriou S, Samara AA, Tsiamalou IA, Donoudis C, Seviloglou E, Skentou C, Garas A, Daponte A. Placental Ultrasonographical Findings during SARS-CoV-2 Infection. Diagnostics (Basel) 2022; 12:974. [PMID: 35454021 PMCID: PMC9032574 DOI: 10.3390/diagnostics12040974] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2022] [Revised: 04/11/2022] [Accepted: 04/12/2022] [Indexed: 01/14/2023] Open
Abstract
Infection with SARS-CoV-2 virus (COVID-19) during pregnancy has been associated with several complications. Increasing evidence suggests that COVID-19 infection leaves tell-tale signs of placental injury. During ultrasound examination and placental evaluation of COVID-19 infected pregnancies, we recorded signs of placental involvement, with findings indicating malperfusion, chorangiosis, deciduitis, and subchorionitis. Early detection of placental damage through the use of specific ultrasound findings could indicate which pregnancies are at increased risk for complications.
Collapse
Affiliation(s)
- Sotirios Sotiriou
- Department of Embryology, Faculty of Medicine, University of Thessaly, 41110 Larissa, Greece; (S.S.); (C.S.)
| | - Athina A. Samara
- Department of Embryology, Faculty of Medicine, University of Thessaly, 41110 Larissa, Greece; (S.S.); (C.S.)
- Department of Obstetrics and Gynecology, University Hospital of Larissa, 41110 Larissa, Greece; (I.-A.T.); (C.D.); (E.S.); (A.G.); (A.D.)
| | - Iokasti-Apostolia Tsiamalou
- Department of Obstetrics and Gynecology, University Hospital of Larissa, 41110 Larissa, Greece; (I.-A.T.); (C.D.); (E.S.); (A.G.); (A.D.)
| | - Christos Donoudis
- Department of Obstetrics and Gynecology, University Hospital of Larissa, 41110 Larissa, Greece; (I.-A.T.); (C.D.); (E.S.); (A.G.); (A.D.)
| | - Eleni Seviloglou
- Department of Obstetrics and Gynecology, University Hospital of Larissa, 41110 Larissa, Greece; (I.-A.T.); (C.D.); (E.S.); (A.G.); (A.D.)
| | - Chara Skentou
- Department of Embryology, Faculty of Medicine, University of Thessaly, 41110 Larissa, Greece; (S.S.); (C.S.)
| | - Antonios Garas
- Department of Obstetrics and Gynecology, University Hospital of Larissa, 41110 Larissa, Greece; (I.-A.T.); (C.D.); (E.S.); (A.G.); (A.D.)
| | - Alexandros Daponte
- Department of Obstetrics and Gynecology, University Hospital of Larissa, 41110 Larissa, Greece; (I.-A.T.); (C.D.); (E.S.); (A.G.); (A.D.)
| |
Collapse
|
7
|
Aboulghar M, Aboulghar M. Placental pathology after assisted reproduction: impact on the outcome of pregnancy. Fertil Steril 2022; 117:769-770. [DOI: 10.1016/j.fertnstert.2022.01.026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Accepted: 01/24/2022] [Indexed: 11/04/2022]
|
8
|
Markovic S, Roussel T, Neeman M, Frydman L. Deuterium Magnetic Resonance Imaging and the Discrimination of Fetoplacental Metabolism in Normal and L-NAME-Induced Preeclamptic Mice. Metabolites 2021; 11:metabo11060376. [PMID: 34200839 PMCID: PMC8230481 DOI: 10.3390/metabo11060376] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 06/03/2021] [Accepted: 06/08/2021] [Indexed: 12/12/2022] Open
Abstract
Recent magnetic resonance studies in healthy and cancerous organs have concluded that deuterated metabolites possess highly desirable properties for mapping non-invasively and, as they happen, characterizing glycolysis and other biochemical processes in animals and humans. A promising avenue of this deuterium metabolic imaging (DMI) approach involves looking at the fate of externally administered 2H6,6′-glucose, as it is taken up and metabolized into different products as a function of time. This study employs deuterium magnetic resonance to follow the metabolism of wildtype and preeclamptic pregnant mice models, focusing on maternal and fetoplacental organs over ≈2 h post-injection. 2H6,6′-glucose uptake was observed in the placenta and in specific downstream organs such as the fetal heart and liver. Main metabolic products included 2H3,3′-lactate and 2H-water, which were produced in individual fetoplacental organs with distinct time traces. Glucose uptake in the organs of most preeclamptic animals appeared more elevated than in the control mice (p = 0.02); also higher was the production of 2H-water arising from this glucose. However, the most notable differences arose in the 2H3,3′-lactate concentration, which was ca. two-fold more abundant in the placenta (p = 0.005) and in the fetal (p = 0.01) organs of preeclamptic-like animals, than in control mice. This is consistent with literature reports about hypoxic conditions arising in preeclamptic and growth-restricted pregnancies, which could lead to an enhancement in anaerobic glycolysis. Overall, the present measurements suggest that DMI, a minimally invasive approach, may offer new ways of studying and characterizing health and disease in mammalian pregnancies, including humans.
Collapse
Affiliation(s)
- Stefan Markovic
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot 7610001, Israel;
| | - Tangi Roussel
- Center for Magnetic Resonance in Biology and Medicine, 13385 Marseille, France;
| | - Michal Neeman
- Department of Biological Regulation, Weizmann Institute of Science, Rehovot 7610001, Israel;
| | - Lucio Frydman
- Department of Chemical and Biological Physics, Weizmann Institute of Science, Rehovot 7610001, Israel;
- Correspondence: ; Tel.: +972-8934-4093
| |
Collapse
|
9
|
Schiffer V, van Haren A, De Cubber L, Bons J, Coumans A, van Kuijk SM, Spaanderman M, Al-Nasiry S. Ultrasound evaluation of the placenta in healthy and placental syndrome pregnancies: A systematic review. Eur J Obstet Gynecol Reprod Biol 2021; 262:45-56. [PMID: 33984727 DOI: 10.1016/j.ejogrb.2021.04.042] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 04/27/2021] [Accepted: 04/29/2021] [Indexed: 12/28/2022]
Abstract
INTRODUCTION An antepartum screening method to determine normal and abnormal placental function is desirable in the prevention of maternal and fetal pregnancy complications. Placental appearance can easily be obtained and evaluated using 2D ultrasonography, but surprisingly little is known about the change in placental appearance during gestation. Aim of this systematic review was to describe the antepartum placental appearance in placenta syndrome (PS) pregnancies, and to compare this to the appearance in healthy pregnancies. METHODS A systematic review investigating placental thickness, -lakes and/or -calcifications by ultrasound examination in both uncomplicated (reference group) and PS pregnancies in relation to gestational age was performed. English literature was searched using PubMed (NCBI), EMBASE (Ovid) and the Cochrane Library, from database inception until September 2020. Data on placental thickness was presented as a continuous variable or as the proportion of abnormal placental thickness. Data on placental lakes and -calcifications was presented as prevalence (%). There was no restriction applied on the definition of placental lakes or -calcifications. Due to heterogeneity, pooling of the results was not performed. RESULTS A total of 28 studies were included describing 1719 PS cases; consisting of 370 (21 %) cases with preeclampsia or pregnancy induced hypertension, 1341 (78 %) cases with fetal growth restriction (FGR) or small for gestational age (SGA), and 8 (1%) cases with combined clinical expressions. In addition, the reference group comprised 3315 pregnant women. Placental thickness showed an increase between the first and second trimester, which was higher in PS- compared to uncomplicated pregnancies. Placental lakes were frequently observed in FGR and SGA pregnancies, especially in the second trimester. Grade 3 calcifications were most prominent in the PS pregnancies, specifically in the late second and third trimester. Moreover, in the reference group, no grade 3 calcifications were reported before 35 weeks of gestation. CONCLUSION Placental appearance in PS-pregnancies shows higher placental thickness and greater presence of placental lakes and -calcifications compared to uncomplicated pregnancies. Standardized definitions of (ab-)normal placental appearance and longitudinal research in both healthy and complicated pregnancies are needed to improve personalized obstetric care.
Collapse
Affiliation(s)
- Veronique Schiffer
- Department of Obstetrics and Gynecology, Maastricht University Medical Centre (MUMC+), the Netherlands; GROW School for Oncology and Developmental Biology, Maastricht University, the Netherlands.
| | - Ashlee van Haren
- Department of Obstetrics and Gynecology, Maastricht University Medical Centre (MUMC+), the Netherlands
| | - Lisa De Cubber
- Department of Obstetrics and Gynecology, Maastricht University Medical Centre (MUMC+), the Netherlands
| | - Judith Bons
- Central Diagnostic Laboratory, Maastricht University Medical Centre (MUMC+), Maastricht, the Netherlands
| | - Audrey Coumans
- Department of Obstetrics and Gynecology, Maastricht University Medical Centre (MUMC+), the Netherlands
| | - Sander Mj van Kuijk
- Department of Clinical Epidemiology and Medical Technology Assessment, Maastricht University Medical Centre (MUMC+), the Netherlands
| | - Marc Spaanderman
- Department of Obstetrics and Gynecology, Maastricht University Medical Centre (MUMC+), the Netherlands
| | - Salwan Al-Nasiry
- Department of Obstetrics and Gynecology, Maastricht University Medical Centre (MUMC+), the Netherlands
| |
Collapse
|
10
|
Intra-System Reliability Assessment of 2-Dimensional Shear Wave Elastography. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11072992] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
The availability of 2-Dimensional Shear Wave Elastography (2D-SWE) technology on modern medical ultrasound systems is becoming increasingly common. The technology is now being used to investigate a range of soft tissues and related pathological conditions. This work investigated the reliability of a single commercial 2D-SWE system using a tissue-mimicking elastography phantom to understand the major causes of intra-system variability. Sources of shear wave velocity (SWV) measurement variability relates to imaging depth, target stiffness, sampling technique and the operator. Higher SWV measurement variability was evident with increasing depth and stiffness of the phantom targets. The influence of the operator was minimal, and variations in sampling technique had little impact on the SWV.
Collapse
|
11
|
Roitman MS, Wainstock T, Sheiner E, Leibson T, Pariente G. Ectopic pregnancy: perinatal outcomes of future gestations and long-term neurological morbidity of the offspring. Arch Gynecol Obstet 2021; 304:633-640. [PMID: 33566161 DOI: 10.1007/s00404-021-05991-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 01/29/2021] [Indexed: 01/29/2023]
Abstract
PURPOSE To evaluate perinatal outcomes and long-term neurological morbidity of offspring to mothers with a history of ectopic pregnancy. METHODS In this retrospective study, perinatal outcomes and long-term neurological morbidity of offspring were assessed among mothers with a history of ectopic pregnancy, either medically or surgically treated. The study groups were followed until 18 years of age for neurological-related morbidity. For perinatal outcomes, generalized estimated equation (GEE) models were used to control for confounders. A Kaplan-Meier survival curve was used to compare cumulative neurological morbidity incidence and Cox proportional hazards model was conducted to control for confounders. RESULTS A total of 243,682 mothers were included; 1424 mothers (0.58%) had a previous ectopic pregnancy, of which 25.6% (n = 365) were treated medically, and 74.3% (n = 1059) were treated surgically. Using GEE models, controlling for confounders, both surgically and medically treated ectopic pregnancies were noted as independent risk factors for preterm delivery in the subsequent pregnancies. Maternal history of surgically treated ectopic pregnancy was also independently associated with cesarean delivery. Offspring to mothers with previous ectopic pregnancy had comparable rates of long-term neurological morbidity. In the Cox proportional hazards model, controlling for confounders, being born to a mother with a history of previous ectopic pregnancy was not found to be independently associated with long-term neurological morbidity of offspring. CONCLUSIONS Maternal history of ectopic pregnancy is independently associated with preterm delivery. However, offspring of mothers with a history of ectopic pregnancy are not at an increased risk for long-term neurological morbidity.
Collapse
Affiliation(s)
- Melanie Shanie Roitman
- Faculty of Health Sciences, Joyce and Irving Goldman Medical School at Ben Gurion University of the Negev, Beer-Sheva, Israel.,Department of Obstetrics and Gynecology, Soroka University Medical Center, Faculty of Health Science, Ben-Gurion University of the Negev, POB 151, 84101, Beer-Sheva, Israel
| | - Tamar Wainstock
- Department of Public Health, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva, Israel
| | - Eyal Sheiner
- Department of Obstetrics and Gynecology, Soroka University Medical Center, Faculty of Health Science, Ben-Gurion University of the Negev, POB 151, 84101, Beer-Sheva, Israel.
| | - Tom Leibson
- Department of Pediatrics, Mount Sinai Hospital, Toronto, ON, Canada.,Division of Clinical Pharmacology and Toxicology, Hospital for Sick Children, Toronto, ON, Canada
| | - Gali Pariente
- Department of Obstetrics and Gynecology, Soroka University Medical Center, Faculty of Health Science, Ben-Gurion University of the Negev, POB 151, 84101, Beer-Sheva, Israel
| |
Collapse
|
12
|
Nguyen CD, Correia-Branco A, Adhikari N, Mercan E, Mallidi S, Wallingford MC. New Frontiers in Placenta Tissue Imaging. EMJ. RADIOLOGY 2020; 1:54-62. [PMID: 35949207 PMCID: PMC9361653 DOI: 10.33590/emjradiol/19-00210] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
The placenta is a highly vascularized organ with unique structural and metabolic complexities. As the primary conduit of fetal support, the placenta mediates transport of oxygen, nutrients, and waste between maternal and fetal blood. Thus, normal placenta anatomy and physiology is absolutely required for maintenance of maternal and fetal health during pregnancy. Moreover, impaired placental health can negatively impact offspring growth trajectories as well as increase the risk of maternal cardiovascular disease later in life. Despite these crucial roles for the placenta, placental disorders, such as preeclampsia, intrauterine growth restriction (IUGR), and preterm birth, remain incompletely understood. Effective noninvasive imaging and image analysis are needed to advance the obstetrician's clinical reasoning toolkit and improve the utility of the placenta in interpreting maternal and fetal health trajectories. Current paradigms in placental imaging and image analysis aim to improve the traditional imaging techniques that may be time-consuming, costly, or invasive. In concert with conventional clinical approaches such as ultrasound (US), advanced imaging modalities can provide insightful information on the structure of placental tissues. Herein we discuss such imaging modalities, their specific applications in structural, vascular, and metabolic analysis of placental health, and emerging frontiers in image analysis research in both preclinical and clinical contexts.
Collapse
Affiliation(s)
- Christopher D. Nguyen
- Tufts University, Department of Biomedical Engineering, 4 Colby St, Medford, MA 02155
| | - Ana Correia-Branco
- Tufts Medical Center, Mother Infant Research Institute, 800 Washington Street Box #394, Boston, MA 02111
- ufts Medical Center, Molecular Cardiology Research Institute, 800 Washington Street Box #394, Boston, MA 02111
| | - Nimish Adhikari
- Tufts University, Department of Computer Science, 419 Boston Ave, Medford, MA 02155
| | - Ezgi Mercan
- Seattle Children’s Hospital, Craniofacial Center, 4800 Sand Point Way NE Seattle, WA 98105
| | - Srivalleesha Mallidi
- Tufts University, Department of Biomedical Engineering, 4 Colby St, Medford, MA 02155
| | - Mary C. Wallingford
- Tufts Medical Center, Mother Infant Research Institute, 800 Washington Street Box #394, Boston, MA 02111
- ufts Medical Center, Molecular Cardiology Research Institute, 800 Washington Street Box #394, Boston, MA 02111
- Tufts University School of Medicine, Obstetrics & Gynecology, 800 Washington Street Box #394, Boston, MA 02111
| |
Collapse
|
13
|
Trilla C, Medina MC, Parra J, Llurba E, Espinós JJ. Inter- and Intraobserver Agreement in First Trimester Ultrasound Evaluation of Placental Biometry. Fetal Diagn Ther 2020; 47:834-840. [PMID: 32784297 DOI: 10.1159/000509707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2019] [Accepted: 06/23/2020] [Indexed: 11/19/2022]
Abstract
OBJECTIVE The aim of this study was to assess the clinical applicability of a new analytical software program by determining the inter- and intraobserver agreement for 2D placental biometry and three-dimensional (3D) placental volume (PV) in the first trimester. METHODS A prospective study of 25 singleton pregnancies between 11 and 14 weeks was conducted. 3D datasets were captured, and PV was estimated using the Phillips QLAB GI3DQ ultrasound quantification software. The basal plate (BP), chorionic plate (CP), placental thickness (PT), and the free uterine surface (FUS) area not occupied by placenta were considered for 2D biometry evaluation. Each variable was measured in 2 orthogonal planes with mean values used for the analysis. Intra- and interobserver agreement was evaluated. RESULTS Intraobserver agreement for both 2D and 3D measurements was high, particularly for the PV and PT (interclass correlation coefficient [ICC] 0.989 [95% confidence interval (CI) 0.97-0.99] and ICC 0.936 [95% CI 0.86-0.97], respectively). Interobserver agreement was good for the PV (ICC 0.963 [95% CI 0.91-0.98]), PT (ICC 0.822 [95% CI 0.63-0.91]), and CP (ICC 0.708 [95% CI 0.44-0.86]), but moderate for BP and FUS. CONCLUSIONS PV, PT, and CP are reproducible measurements to evaluate first trimester placental biometry. Further research is needed to assess the clinical utility of these variables as predictors of poor obstetric outcomes.
Collapse
Affiliation(s)
- Cristina Trilla
- Department of Obstetrics and Gynecology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Maria C Medina
- Department of Obstetrics and Gynecology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Juan Parra
- Department of Obstetrics and Gynecology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| | - Elisa Llurba
- Department of Obstetrics and Gynecology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain,
| | - Juan José Espinós
- Department of Obstetrics and Gynecology, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
| |
Collapse
|
14
|
Advances in imaging feto-placental vasculature: new tools to elucidate the early life origins of health and disease. J Dev Orig Health Dis 2020; 12:168-178. [PMID: 32746961 DOI: 10.1017/s2040174420000720] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Optimal placental function is critical for fetal development, and therefore a crucial consideration for understanding the developmental origins of health and disease (DOHaD). The structure of the fetal side of the placental vasculature is an important determinant of fetal growth and cardiovascular development. There are several imaging modalities for assessing feto-placental structure including stereology, electron microscopy, confocal microscopy, micro-computed tomography, light-sheet microscopy, ultrasonography and magnetic resonance imaging. In this review, we present current methodologies for imaging feto-placental vasculature morphology ex vivo and in vivo in human and experimental models, their advantages and limitations and how these provide insight into placental function and fetal outcomes. These imaging approaches add important perspective to our understanding of placental biology and have potential to be new tools to elucidate a deeper understanding of DOHaD.
Collapse
|
15
|
Edwards C, Cavanagh E, Kumar S, Clifton V, Fontanarosa D. The use of elastography in placental research - A literature review. Placenta 2020; 99:78-88. [PMID: 32763616 DOI: 10.1016/j.placenta.2020.07.014] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/04/2020] [Accepted: 07/15/2020] [Indexed: 01/18/2023]
Abstract
INTRODUCTION Ultrasound elastography is a technique used to quantify biomechanical changes that occur in parenchymal tissue with disease. Recent research has applied the technique to the placenta in order to investigate changes associated with uteroplacental dysfunction. We performed a literature review to summarise the current available information regarding this novel technique. METHODS Pubmed, CINAHL and Embase were searched using the terms "placenta", "ultrasound" and "elastography". Only full text studies written in English and limited to placental sonoelastography were included. RESULTS Twenty-eight studies met the inclusion criteria and were included in this review. Publications were divided into in vivo and ex vivo groups, and further categorised into four subgroups: normal pregnancy, pregnancy-induced hypertension and pre-eclampsia, fetal growth restriction and other pregnancy complications. CONCLUSION Ultrasound elastography can quantitatively assess biomechanical properties of the placenta in conditions where placental function is compromised.
Collapse
Affiliation(s)
- Christopher Edwards
- Queensland University of Technology (QUT), Faculty of Health, School of Clinical Sciences, Institute of Health and Biomedical Innovation, Brisbane, QLD, 4000, Australia; Mater Research Institute, University of Queensland, Level 3, Aubigny Place, Raymond Terrace, South Brisbane, QLD, 4101, Australia
| | - Erika Cavanagh
- Queensland University of Technology (QUT), Faculty of Health, School of Clinical Sciences, Institute of Health and Biomedical Innovation, Brisbane, QLD, 4000, Australia; Mater Research Institute, University of Queensland, Level 3, Aubigny Place, Raymond Terrace, South Brisbane, QLD, 4101, Australia
| | - Sailesh Kumar
- Queensland University of Technology (QUT), Faculty of Health, School of Clinical Sciences, Institute of Health and Biomedical Innovation, Brisbane, QLD, 4000, Australia; Mater Research Institute, University of Queensland, Level 3, Aubigny Place, Raymond Terrace, South Brisbane, QLD, 4101, Australia; University of Queensland, Faculty of Medicine, Herston, QLD, 4006, Australia.
| | - Vicki Clifton
- Mater Research Institute, University of Queensland, Level 3, Aubigny Place, Raymond Terrace, South Brisbane, QLD, 4101, Australia; University of Queensland, Faculty of Medicine, Herston, QLD, 4006, Australia
| | - Davide Fontanarosa
- Queensland University of Technology (QUT), Faculty of Health, School of Clinical Sciences, Institute of Health and Biomedical Innovation, Brisbane, QLD, 4000, Australia.
| |
Collapse
|
16
|
Diagnosis and Management of Placental Mesenchymal Disease. A Review of the Literature. Obstet Gynecol Surv 2020; 74:611-622. [PMID: 31670834 DOI: 10.1097/ogx.0000000000000716] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
Objective To review what is currently known about placental mesenchymal dysplasia (PMD) including imaging techniques for diagnosis and differentiation from a molar pregnancy, genetics, maternal/fetal effects, and management. Evidence Acquisition A literature search by research librarians at 2 universities was undertaken using the search engines PubMed and Web of Science. The search terms used were "etiology" OR "cause" OR "risk" OR "risks" OR "epidemiology" OR "diagnosis" OR "therapy" OR "prognosis" OR "management" AND "placental mesenchymal dysplasia" OR "placenta" AND "mesenchymal dysplasia." No limit was put on the number of years searched. Results The etiology of PMD remains uncertain, although there are a number of theories on causation. An elevated maternal serum α-fetoprotein level, slightly elevated human chorionic gonadotropin level, normal karyotype, multicystic lesions on ultrasound, and varying degrees of flow within cysts using color Doppler (stained-glass appearance) are helpful in making the diagnosis. On pathologic examination of the placenta, PMD is differentiated from molar pregnancy by the absence of trophoblastic hyperplasia. Fetal complications of PMD include hematologic disorders, Beckwith-Wiedemann syndrome, liver tumors, fetal growth restriction, preterm delivery, and intrauterine fetal demise. Maternal complications include gestational hypertension, preeclampsia, HELLP (hemolysis, elevated liver function tests, low platelets) syndrome, and eclampsia. Conclusions Accurate diagnosis of PMD is imperative for appropriate management and surveillance to minimize adverse maternal and fetal outcomes. Relevance The importance of a correct diagnosis of PMD is important because it can be misdiagnosed as a partial molar pregnancy or a complete mole with coexisting normal fetus, and this can result in inappropriate management.
Collapse
|
17
|
Ismail KI, Hannigan A, O'Donoghue K, Cotter A. Role of 2-Dimensional Ultrasound Imaging in Placental and Umbilical Cord Morphometry: Literature and Pictorial Review. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2019; 38:3131-3140. [PMID: 31144344 DOI: 10.1002/jum.15024] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/25/2018] [Accepted: 04/23/2019] [Indexed: 06/09/2023]
Abstract
Abnormalities of the placenta and umbilical cord have been associated with adverse pregnancy outcomes. Antenatal detection of placental and umbilical cord abnormalities using ultrasound (US) imaging is now gaining popularity with the advancements in obstetric US. This article reviews the use of 2-dimensional obstetric US as a tool to measure and assess placental and umbilical cord morphometry. It highlights the potential role of placental and umbilical cord morphometry as a valuable component of the screening tool for high risk pregnancies and identifies the need for further research to examine its feasibility.
Collapse
Affiliation(s)
- Khadijah I Ismail
- Departments of Obstetrics and Gynecology, Graduate Entry Medical School, University of Limerick, Limerick, Ireland
| | - Ailish Hannigan
- Departments of Biostatistics, Graduate Entry Medical School, University of Limerick, Limerick, Ireland
| | - Keelin O'Donoghue
- Department of Obstetrics and Gynecology, University College Cork, Cork, Ireland
| | - Amanda Cotter
- Departments of Obstetrics and Gynecology, Graduate Entry Medical School, University of Limerick, Limerick, Ireland
| |
Collapse
|
18
|
Hu R, Singla R, Deeba F, Rohling RN. Acoustic Shadow Detection: Study and Statistics of B-Mode and Radiofrequency Data. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2248-2257. [PMID: 31101443 DOI: 10.1016/j.ultrasmedbio.2019.04.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/20/2018] [Revised: 02/12/2019] [Accepted: 04/01/2019] [Indexed: 06/09/2023]
Abstract
An acoustic shadow is an ultrasound artifact occurring at boundaries between significantly different tissue impedances, resulting in signal loss and a dark appearance. Shadow detection is important as shadows can identify anatomical features or obscure regions of interest. A study was performed to scan human participants (N = 37) specifically to explore the statistical characteristics of various shadows from different anatomy and with different transducers. Differences in shadow statistics were observed and used for shadow detection algorithms with a fitted Nakagami distribution on radiofrequency (RF) speckle or cumulative entropy on brightness-mode (B-mode) data. The fitted Nakagami parameter and entropy values in shadows were consistent across different transducers and anatomy. Both algorithms utilized adaptive thresholding, needing only the transducer pulse length as an input parameter for easy utilization by different operators or equipment. Mean Dice coefficients (± standard deviation) of 0.90 ± 0.07 and 0.87 ± 0.08 were obtained for the RF and B-mode algorithms, which is within the range of manual annotators. The high accuracy in different imaging scenarios indicates that the shadows can be detected with high versatility and without expert configuration. The understanding of shadow statistics can be used for more specialized techniques to be developed for specific applications in the future, including pre-processing for machine learning and automatic interpretation.
Collapse
Affiliation(s)
- Ricky Hu
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada.
| | - Rohit Singla
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada
| | - Farah Deeba
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada
| | - Robert N Rohling
- Department of Electrical and Computer Engineering, University of British Columbia, Vancouver, Canada; Department of Mechanical Engineering, University of British Columbia, Vancouver, Canada
| |
Collapse
|
19
|
N Dilek O, Ozsay O, Karaisli S, Ö Gür E, Er A, G Haciyanli S, Kar H, H Dilek F. Striking Multiple Primary Tumors that underwent Whipple Procedure due to Periampullary Carcinoma: An Analysis of 21 Cases. Euroasian J Hepatogastroenterol 2018; 8:1-5. [PMID: 29963453 PMCID: PMC6024055 DOI: 10.5005/jp-journals-10018-1249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2017] [Accepted: 01/12/2018] [Indexed: 11/23/2022] Open
Abstract
Introduction The term multiple primary tumor (MPT) is used to describe cases where two or more primary tumors show no histopathological similarities in between. Multiple primary tumor cases have begun to increase in recent years as a result of the increase in life expectancy because of the increase in life standards and progress in diagnostic methods. In this study, MPT cases with periampullary tumors that underwent Whipple procedure were discussed in the light of literature data. Materials and methods The patient files of 223 cases with periampullary tumors that underwent Whipple procedure in our hospital during the last 6 years were examined retrospectively. More than one primary tumor was detected in 21 patients. Results Periampullary carcinomas were detected as a second primary tumor in 18 patients. First primary tumor was periampullary carcinoma in 3 patients that underwent Whipple procedure. After the Whipple procedure, 5 patients died due to early complications in the first 30 days and 6 patients died due to metastases and additional problems that developed during follow-up. Discussion The incidence of MPT has been reported as 0.7 to 14.5% in the literature. Most of them are multiple primary case presentations. In patient management, it is recommended that each tumor should be evaluated independently of its own characteristics, and treatment and follow-up should be planned accordingly. Conclusion The MPT cases are increasing. The possibility of MPT as well as metastasis should be kept in mind during the evaluation of tumor foci seen during diagnosis and follow-up of patients. The characteristics of each tumor, survival, and prognosis should be evaluated separately and the most appropriate treatment should be offered to the patient. It is recommended that synchronic primary tumors which are considered to be surgically resectable without metastasis should be removed in the same session.How to cite this article: Dilek ON, Ozsay O, Karaisli S, Gür EÖ, Er A, Haciyanli SG, Kar H, Dilek FH. Striking Multiple Primary Tumors that underwent Whipple Procedure due to Periampullary Carcinoma: An Analysis of 21 Cases. Euroasian J Hepato-Gastroenterol 2018;8(1):1-5.
Collapse
Affiliation(s)
- Osman N Dilek
- Department of Surgery, Izmir Katip Çelebi University School of Medicine, Izmir, Turkey
| | - Oguzhan Ozsay
- Department of Surgery, Izmir Katip Çelebi University School of Medicine, Izmir, Turkey
| | - Serkan Karaisli
- Department of Surgery, Izmir Katip Çelebi University School of Medicine, Izmir, Turkey
| | - Emine Ö Gür
- Department of Surgery, Izmir Katip Çelebi University School of Medicine, Izmir, Turkey
| | - Ahmet Er
- Department of Surgery, Izmir Katip Çelebi University School of Medicine, Izmir, Turkey
| | - Selda G Haciyanli
- Department of Surgery, Izmir Katip Çelebi University School of Medicine, Izmir, Turkey
| | - Haldun Kar
- Department of Surgery, Izmir Katip Çelebi University School of Medicine, Izmir, Turkey
| | - Fatma H Dilek
- Department of Pathology, Izmir Katip Çelebi University, Ataturk Research and Education Hospital, Izmir, Turkey
| |
Collapse
|
20
|
Kaya M, Akdogan R, Uçmak F, O Ayyildiz M, Karakus A, A Kaplan M. The Incidence and Predictive Factors in the Development of Acute Hepatitis in Patients with Leukemia. Euroasian J Hepatogastroenterol 2018; 8:31-37. [PMID: 29963458 PMCID: PMC6024041 DOI: 10.5005/jp-journals-10018-1254] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 01/24/2018] [Indexed: 11/23/2022] Open
Abstract
Introduction Liver involvement is common in hematological malignancies, but the incidence and pattern of liver injury vary among the different types. The aims of our study were to determine the incidence and clinical course of acute hepatitis and the important factors for its development in patients with leukemia after chemotherapy. Materials and methods All patients with the diagnosis of leukemia who were treated at the Department of Hematology between January 2008 and January 2013 were included in the study. A detailed medical history, clinical and laboratory findings, treatment modalities, complications, and clinical course were recorded retrospectively. Results A total of 124 patients (64 females) with the diagnosis of leukemia were included in the study. The mean age was 45.2 years (16-89 years) and mean follow-up time was 29.7 months (0.25-192 months). A total of 43 (34.6%) patients had acute hepatitis after chemotherapy. Pattern of liver injury was hepatocellular in 31 patients, cholestasis in 2, and mix in 10 patients. Age (p = 0.001), hepatitis B surface antigen (HBsAg, p = 0.007), acute leukemia (p < 0.001), positive blood culture (p = 0.004), the amount of transfused red blood cell (p = 0.001), and amount of transfused platelets (p = 0.002) were significantly different under univariate analysis between the acute hepatitis group and the nonacute hepatitis group. Under multivariate analysis, only acute lymphoblastic leukemia (ALL) was identified as independent predictive factor for development of acute hepatitis after starting chemotherapy. Conclusion Acute and self-limited hepatitis develops in the substantial proportion of patients with leukemia. The most important factor for development of acute hepatitis is the type of leukemia. How to cite this article: Kaya M, Akdogan R, Uçmak F, Ayyildiz MO, Karakus A, Kaplan MA. The Incidence and Predictive Factors in the Development of Acute Hepatitis in Patients with Leukemia. Euroasian J Hepato-Gastroenterol 2018;8(1):31-37.
Collapse
Affiliation(s)
- Muhsin Kaya
- Department of Gastroenterology, Dicle University School of Medicine, Diyarbakir, Turkey
| | - Recai Akdogan
- Department of Internal Medicine, Dicle University School of Medicine, Diyarbakir, Turkey
| | - Feyzullah Uçmak
- Department of Gastroenterology, Dicle University School of Medicine, Diyarbakir, Turkey
| | - Mehmet O Ayyildiz
- Department of Hematology, Dicle University School of Medicine, Diyarbakir, Turkey
| | - Abdullah Karakus
- Department of Hematology, Dicle University School of Medicine, Diyarbakir, Turkey
| | - Muhammet A Kaplan
- Department of Oncology, Dicle University School of Medicine, Diyarbakir, Turkey
| |
Collapse
|
21
|
Aguiar J, A Silva J, García G, Guillén G, C Aguilar J. Cross-validation Studies of a Novel Low-cost Hepatitis B Virus Quantitative Polymerase Chain Reaction System. Euroasian J Hepatogastroenterol 2018; 8:38-41. [PMID: 29963459 PMCID: PMC6024048 DOI: 10.5005/jp-journals-10018-1255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 01/25/2018] [Indexed: 11/23/2022] Open
Abstract
Aim This research focused on the results of the cross-validation program related with the performance of a Cuban novel low-cost real-time quantitative polymerase chain reaction (qPCR) assay for hepatitis B virus (HBV) quantification developed by the Therapeutic Vaccine against Hepatitis B Department, Vaccines Division, Center for Genetic Engineering and Biotechnology (CIGB), Havana, Cuba. Materials and methods Dilution series with the plasmid standard at concentrations of 900,000 to 0.09 copies/reaction (c/r) were made for each PCR instrument. The mean cycles threshold (Ct) values and PCR efficiency were compared among the cyclers. Hepatitis B virus-positive serum samples were used for the calculation of reproducibility of the HBV assay. Biotecon Diagnostics (BCD) also ordered the oligo sequences from a second supplier and compared the PCR performance to those provided from the CIGB. Results All PCR cyclers were able to detect concentrations up to 0.09 c/r. However, below the concentration of 9 c/r, the variation of results increased within and between the cyclers. The PCR efficiency showed satisfying results. The overall coefficient of variation (CV) cycler values were 1.29 and 0.91% for M6 and M19 respectively. No significance was observed between the different primer suppliers. Conclusion The HBV assay was performed with a good concordance between the five real-time instruments from different suppliers. The HBV assay was also performed with a high reproducibility for samples with a high and a low viral load. The HBV assay is robust against different primer suppliers. How to cite this article: Aguiar J, Silva JA, García G, Guillén G, Aguilar JC. Cross-validation Studies of a Novel Low-cost Hepatitis B Virus Quantitative Polymerase Chain Reaction System. Euroasian J Hepato-Gastroenterol 2018;8(1):38-41.
Collapse
Affiliation(s)
- Jorge Aguiar
- Department of Therapeutic Vaccine against Hepatitis B, Center for Genetic Engineering and Biotechnology (CIGB), Havana, Cuba
| | - José A Silva
- Department of Oligonucleotide Synthesis, Center for Genetic Engineering and Biotechnology (CIGB), Havana, Cuba
| | - Gerardo García
- Department of Quality Control, Center for Genetic Engineering and Biotechnology (CIGB), Havana, Cuba
| | - Gerardo Guillén
- Department of Therapeutic Vaccine against Hepatitis B, Center for Genetic Engineering and Biotechnology (CIGB), Havana, Cuba
| | - Julio C Aguilar
- Department of Therapeutic Vaccine against Hepatitis B, Center for Genetic Engineering and Biotechnology (CIGB), Havana, Cuba
| |
Collapse
|
22
|
Malipatel R, Patil M, Pritilata Rout P, Correa M, Devarbhavi H. Primary Gastric Lymphoma: Clinicopathological Profile. Euroasian J Hepatogastroenterol 2018; 8:6-10. [PMID: 29963454 PMCID: PMC6024034 DOI: 10.5005/jp-journals-10018-1250] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2017] [Accepted: 01/18/2018] [Indexed: 12/19/2022] Open
Abstract
Introduction Gastrointestinal tract (GIT) is the most common site of involvement of extranodal non-Hodgkin’s lymphoma (NHL). There is regional variation in anatomical distribution of extranodal NHL, stomach being the most common site followed by small intestine. Primary gastric lymphoma (PGL) predominantly involves the antrum and corpus of the stomach. It arises from mucosa-associated lymphoid tissue (MALT) and is of B-cell lineage and often associated with Helicobacter pylori infection. Primary gastric lymphoma often presents with nonspecific symptoms. The present study was undertaken to ascertain the clinicopathological characteristics of PGL at a tertiary care center in South India. Materials and methods It is a retrospective study from 2006 to 2016. Patient’s data were obtained from institutional medical records. The histopathology slides were reviewed. The relevant immunohistochemistry (IHC) markers done were leukocyte common antigen (LCA), CD3, CD20, CD79a, CD10, Bcl-2, Bcl-6, CD5, Cyclin D1, CD138, and Ki-67. Correlating with the immunoprofile, further subtyping was done. Results A total of 405 patients of NHL were seen during the study period, out of which 43 patients were PGL. There were 32 males and 11 females, with M:F of 2.9:1. The mean age at diagnosis was 58 years. Abdominal pain and new-onset dyspepsia were the commonly observed presenting symptoms. The common site of involvement was antrum (20). Diffuse large B-cell lymphoma (DLBCL) was the most common histological subtype. Helicobacter pylori infection was seen in 18 (41%) patients. Majority of the patients were in stages II and III. Conclusion In our study, the initial presentation of PGL was with nonspecific symptoms like abdominal pain and new-onset dyspepsia. High degree of suspicion of such symptoms and biopsy of all suspicious lesions is essential for early detection. Diffuse large B-cell lymphoma was the most common histological subtype seen in our study. How to cite this article: Malipatel R, Patil M, Rout P, Correa M, Devarbhavi H. Primary Gastric Lymphoma: Clinicopathological Profile. Euroasian J Hepato-Gastroenterol 2018;8(1):6-10.
Collapse
Affiliation(s)
- Renuka Malipatel
- Department of Pathology, St. John's Medical College, Bengaluru, Karnataka, India
| | - Mallikarjun Patil
- Department of Gastroenterology, St. John's Medical College, Bengaluru, Karnataka, India
| | - Patil Pritilata Rout
- Department of Pathology, St. John's Medical College, Bengaluru, Karnataka, India
| | - Marjorie Correa
- Department of Pathology, St. John's Medical College, Bengaluru, Karnataka, India
| | - Harshad Devarbhavi
- Department of Gastroenterology, St. John's Medical College, Bengaluru, Karnataka, India
| |
Collapse
|
23
|
Mf Akbar S, Al-Mahtab M, I Khan S. Nature of Host Immunity during Hepatitis B Virus Infection and designing Immune Therapy. Euroasian J Hepatogastroenterol 2018; 8:42-46. [PMID: 29963460 PMCID: PMC6024052 DOI: 10.5005/jp-journals-10018-1256] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/09/2018] [Accepted: 02/14/2018] [Indexed: 12/23/2022] Open
Abstract
Hepatitis B virus (HBV) infections represent one of the major public health problems in global context. More than 2 billion people in the world have been infected with this virus at some point of time in their life and millions are chronically infected, indicating that chronic HBV-infected subjects remain as a living source of HBV transmission. The public health impact of this is tremendous. Considerable numbers of chronic HBV-infected individuals would eventually develop progressive liver diseases and their complications like hepatic failure, liver cirrhosis (LC), and hepatocellular carcinoma (HCC). Epidemiological studies have suggested that about 0.6 to 1.2 million people die annually from HBV-related liver diseases. These figures about death due to HBV and sufferings from HBV-related diseases indicate a notion of medical emergencies about HBV. In addition to these, the impact of HBV on health care delivery system moves beyond these numbers of HBV-related patients and HB-related deaths. This is because significant insights have already been developed about epidemiology, virology, and pathogenesis of HBV. Also, an effective and widely used preventive vaccine is available against HBV. In addition to these, antiviral drugs against HBV have been developed from early 1980s and several such drugs are now available commercially in the open market around the worldwide. Unfortunately, the ongoing therapeutic regimens could not stand the test of time and new insights about HBV pathogenesis are required for the development of new, novel, and evidence-based therapies for chronic HBV infections. How to cite this article: Akbar SMF, Al-Mahtab M, Khan SI. Nature of Host Immunity during Hepatitis B Virus Infection and designing Immune Therapy. Euroasian J Hepato-Gastroenterol 2018;8(1):42-46.
Collapse
Affiliation(s)
- Sheikh Mf Akbar
- Department of Medical Sciences, Toshiba General Hospital, Tokyo, Japan and Miyakawa Memorial Research Foundation, Tokyo Japan
| | - Mamun Al-Mahtab
- Department of Hepatology, Bangabandhu Sheikh Mujib Medical University, Dhaka, Bangladesh
| | - Sakirul I Khan
- Department of Anatomy and Embryology, Graduate School of Medicine, Ehime University, Ehime, Japan
| |
Collapse
|
24
|
Yakut M, Özkan H, F Karakaya M, Erdal H. Diagnostic and Prognostic Role of Serum Interleukin-6 in Malignant Transformation of Liver Cirrhosis. Euroasian J Hepatogastroenterol 2018; 8:23-30. [PMID: 29963457 PMCID: PMC6024044 DOI: 10.5005/jp-journals-10018-1253] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/24/2017] [Accepted: 01/28/2018] [Indexed: 12/15/2022] Open
Abstract
Aim Alpha-fetoprotein (AFP) is still the most commonly used and the single most recommended marker in the diagnosis of hepatocellular carcinoma (HCC). Interleukin (IL)-6 is a circular cytokine and its role on carcinogenesis in various hematological and solid tumors is clearly documented. A combination of serum IL-6 and AFP may provide beneficial information regarding early diagnosis of HCC. In this study, the effect of plasma IL-6 level in the diagnosis of HCC was investigated. Materials and methods A total of 130 patients with liver cirrhosis, together with 30 control cases were enrolled in the trial. A diagnosis of HCC was present in 75 patients (57.6%) in the liver cirrhosis group. Blood samples were obtained from the enrolled study and control cases. Alpha-fetoprotein was quantified by chemiluminescent method. Plasma IL-6 levels of samples obtained at -80°C were quantified by human IL-6 BMS213/2 BMS213/2TEN kit. Results The HCC patients were older than the patients in the cirrhosis group (p = 0.016). On comparison of the HCC patients with the control group, AFP (p < 0.001) and IL-6 (p < 0.001) were significantly higher among the HCC patients. Comparison of HCC patients with liver cirrhosis cases with no diagnosis of HCC revealed significantly high AFP (p < 0.001) and IL-6 levels (p < 0.001) in HCC group. Cutoff value for IL-6 was calculated as 5.73 (pg/mL). No difference was detected in AFP (p = 0.600) and IL-6 (0.344) in all three subgroups. A total of 17 patients died during a mean follow-up period of 32.9 months. No correlation was found between mean AFP values and IL-6 values and survival rates. Conclusion Plasma IL-6 level was found to be significant in the diagnosis of HCC. Alpha-fetoprotein and IL-6 provided no advantage in terms of early diagnosis of HCC and no correlation was observed between these markers and survival. How to cite this article: Yakut M, Özkan H, Karakaya MF, Erdal H. Diagnostic and Prognostic Role of Serum Interleukin-6 in Malignant Transformation of Liver Cirrhosis. Euroasian J Hepato-Gastroenterol 2018;8(1):23-30.
Collapse
Affiliation(s)
- Mustafa Yakut
- Department of Gastroenterology, Memorial Diyarbakir Hospital, Diyarbakir, Turkey
| | - Hasan Özkan
- Department of Gastroenterology, Ankara University School of Medicine, Ankara, Turkey
| | - Muhammed F Karakaya
- Department of Gastroenterology, Ankara University School of Medicine, Ankara, Turkey
| | - Harun Erdal
- Department of Gastroenterology, Düzce Public Hospital, Düzce, Turkey
| |
Collapse
|
25
|
Placental physiology monitored by hyperpolarized dynamic 13C magnetic resonance. Proc Natl Acad Sci U S A 2018; 115:E2429-E2436. [PMID: 29444856 DOI: 10.1073/pnas.1715175115] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
Placental functions, including transport and metabolism, play essential roles in pregnancy. This study assesses such processes in vivo, from a hyperpolarized MRI perspective. Hyperpolarized urea, bicarbonate, and pyruvate were administered to near-term pregnant rats, and all metabolites displayed distinctive behaviors. Little evidence of placental barrier crossing was observed for bicarbonate, at least within the timescales allowed by 13C relaxation. By contrast, urea was observed to cross the placental barrier, with signatures visible from certain fetal organs including the liver. This was further evidenced by the slower decay times observed for urea in placentas vis-à-vis other maternal compartments and validated by mass spectrometric analyses. A clear placental localization, as well as concurrent generation of hyperpolarized lactate, could also be detected for [1-13C]pyruvate. These metabolites also exhibited longer lifetimes in the placentas than in maternal arteries, consistent with a metabolic activity occurring past the trophoblastic interface. When extended to a model involving the administration of a preeclampsia-causing chemical, hyperpolarized MR revealed changes in urea's transport, as well as decreases in placental glycolysis vs. the naïve animals. These distinct behaviors highlight the potential of hyperpolarized MR for the early, minimally invasive detection of aberrant placental metabolism.
Collapse
|
26
|
Ohara T, Suzutani T. Intake of Bifidobacterium longum and Fructo-oligosaccharides prevents Colorectal Carcinogenesis. Euroasian J Hepatogastroenterol 2018; 8:11-17. [PMID: 29963455 PMCID: PMC6024036 DOI: 10.5005/jp-journals-10018-1251] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/20/2017] [Accepted: 01/22/2018] [Indexed: 12/30/2022] Open
Abstract
INTRODUCTION We aimed to investigate the effects of intake of yogurt containing Bifidobacterium longum (BB536-y) and fructo-oligosaccharides (FOS) in preventing colorectal carcinogenesis in healthy subjects, and the preventive effects of short-chain fatty acids (SCFA), whose production was enhanced by the intake of BB536-y and FOS, in human colon cancer cell lines. MATERIALS AND METHODS The subjects were 27 healthy persons who were divided into a group taking yogurt containing BB536 (BB536-y group; n = 14) and a group taking yogurt containing BB536 and FOS (BB536-y with FOS group; n = 13) once a day for 5 weeks. The feces were sampled before and after the intake to analyze the amount of SCFA in the feces and the profile of intestinal flora, such as putrefactive bacteria and Bacteroides fragilis enterotoxin (ETBF). Subsequently, human colon cancer cell lines (DLD-1 cells, WirDr cells) were cultured in the presence of SCFA (butyric acid, isobutyric acid, acetic acid) in order to evaluate the cell growth-inhibitory activity of SCFA (WST-8 assay) by calculating the IC50 value from the dose-response curve. RESULTS Intake of BB536-y increased the total amount of SCFA in the feces and significantly suppressed the detection rate of ETBF and growth of putrefactive bacteria. Intake of BB536-y with FOS was associated with a higher Bifidobacterium detection rate than that of BB536-y alone. The contents of butyric acid, isobutyric acid, and acetic acid, namely, of SCFA, were also decreased. Analysis of the results of culture of DLD-1 cells and WirDr cells in the presence of butyric acid, isobutyric acid, and acetic acid revealed that each of the substances showed significant cell growth-inhibitory activity, with the activity being the highest for butyric acid, followed by that for isobutyric acid and acetic acid. CONCLUSION These findings suggest that intake of both BB536-y and BB536-y with FOS prevents colorectal carcinogenesis.How to cite this article: Ohara T, Suzutani T. Intake of Bifidobacterium longum and Fructo-oligosaccharides prevents Colorectal Carcinogenesis. Euroasian J Hepato-Gastroenterol 2018;8(1):11-17.
Collapse
Affiliation(s)
- Tadashi Ohara
- Department of Intestinal Bioscience and Medicine, Fukushima Medical University, Fukushima City, Fukushima, Japan
| | - Tatsuo Suzutani
- Department of Microbiology, Fukushima Medical University, Fukushima City, Fukushima, Japan
| |
Collapse
|
27
|
Hossain E, Ahammed F, K Saha S, A Foez S, A Rahim M, M Noor-E-Alam S, S Abdullah A. Screening of Esophageal Varices by Noninvasive Means in Chronic Liver Disease. Euroasian J Hepatogastroenterol 2018; 8:18-22. [PMID: 29963456 PMCID: PMC6024039 DOI: 10.5005/jp-journals-10018-1252] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/08/2018] [Accepted: 02/22/2018] [Indexed: 11/23/2022] Open
Abstract
Introduction Noninvasive assessment of esophageal varices (EV) decreases the medical and financial burden related to screening and helps in the management of patients with chronic liver diseases (CLDs). In this study, our aim was to assess the utility of the platelet count/spleen diameter index for the noninvasive evaluation of EV. Materials and methods In this cross-sectional observational study, a total of 100 CLD patients underwent screening endoscopy for EV in Medicine and Gastroenterology Department, Sylhet MAG Osmani Medical College Hospital, Sylhet, Bangladesh. Platelet count/spleen diameter ratio was assessed in all patients and its diagnostic implication was calculated. Results Upper gastrointestinal endoscopy revealed that 45 (45.0%) patients had medium EV followed by 27 (27.0%) that had small EV and 19 (19.0%) patients had large EV. Receiver operator characteristic (ROC) curve was constructed using platelet count/spleen index, which gave a cut-off value of >905. The validity of platelet count/spleen index evaluation of CLD was: Sensitivity 92.3%, specificity 66.7%, accuracy 90.0%, positive predictive value (PPV) and negative predictive value (NPV) were 96.6 and 46.2% respectively. True positive was 84 cases, false positive 3 cases, false negative 7 cases, and true negative 6 cases. If we consider cut-off value as 909 in the evaluation of EV in CLD, then true positive was 85 cases, false positive 3 cases, false negative 6 cases, and true negative 6 cases. From this, by calculation, sensitivity was 93.4%, specificity 66.7%, accuracy 91%, PPV 96.6%, and NPV 50%. Conclusion The platelet count/spleen index may be proposed to be a safe and reliable mean of screening of EV in CLD patients; however, case-control study would be required to validate this. How to cite this article: Hossain E, Ahammed F, Saha SK, Foez SA, Rahim MA, Noor-e-Alam SM, Abdullah AS. Screening of Esophageal Varices by Noninvasive Means in Chronic Liver Disease. Euroasian J Hepato-Gastroenterol 2018;8(1):18-22.
Collapse
Affiliation(s)
- Enayet Hossain
- Department of Medicine, Sylhet MAG Osmani Medical College, Sylhet, Bangladesh
| | - Ferdaus Ahammed
- Department of Medicine, Sylhet MAG Osmani Medical College, Sylhet, Bangladesh
| | - Satyajit K Saha
- Department of Medicine, Sylhet MAG Osmani Medical College, Sylhet, Bangladesh
| | - Syed A Foez
- Department of Hepatology, Sylhet MAG Osmani Medical College, Sylhet, Bangladesh
| | - Mohammad A Rahim
- Department of Hepatology, Abdul Malek Ukil Medical College, Noakhali, Bangladesh
| | - Sheikh M Noor-E-Alam
- Department of Hepatology, Bangabandhu Sheikh Mujib Medical University, Dhaka, Bangladesh
| | - Abu S Abdullah
- Department of Medicine, Moulvibazar District Sadar Hospital, Moulvibazar, Bangladesh
| |
Collapse
|
28
|
Fadl S, Moshiri M, Fligner CL, Katz DS, Dighe M. Placental Imaging: Normal Appearance with Review of Pathologic Findings. Radiographics 2017; 37:979-998. [PMID: 28493802 DOI: 10.1148/rg.2017160155] [Citation(s) in RCA: 59] [Impact Index Per Article: 7.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The placenta plays a crucial role throughout pregnancy, and its importance may be overlooked during routine antenatal imaging evaluation. Detailed systematic assessment of the placenta at ultrasonography (US), the standard imaging examination during pregnancy, is important. Familiarity with the normal and abnormal imaging appearance of the placenta along with the multimodality and methodical approach for evaluation of its related abnormalities is necessary, so that radiologists can alert clinicians regarding appropriate prompt management decisions. This will potentially decrease fetal and maternal morbidity and mortality. This article reviews early placental formation and the expected imaging appearance of the placenta during pregnancy, as well as variations in its morphology. It also discusses various placental diseases and their potential clinical consequences. Placental pathologic conditions include abnormalities of placental size, cord insertion, placental and cord location, and placental adherence. Other conditions such as bleeding in and around the placenta, as well as trophoblastic and nontrophoblastic tumors of the placenta, are also discussed. US with Doppler imaging is the initial imaging modality of choice for placental evaluation. Magnetic resonance (MR) imaging is reserved for equivocal cases or when additional information is needed. Computed tomography (CT) has a limited role in evaluation of placental abnormalities because of the ionizing radiation exposure and the relatively limited assessment of the placenta; however, CT can provide important information in specific circumstances, particularly evaluation of trauma and staging of choriocarcinoma. This article also addresses recent techniques and updates in placental imaging, including elastography, diffusion-weighted MR imaging, and blood oxygen level-dependent (BOLD) MR imaging. These advanced imaging techniques may provide additional information in evaluation of abnormal placental adherence and new insights into placental pathophysiology in selected patients. Online supplemental material is available for this article. ©RSNA, 2017.
Collapse
Affiliation(s)
- Shaimaa Fadl
- From the Departments of Radiology (S.F., M.M., M.D.) and Pathology (C.L.F.), University of Washington Medical Center, 1959 NE Pacific St, Seattle, WA 98195; and Department of Radiology, Winthrop Radiology Associates, Mineola, NY (D.S.K.)
| | - Mariam Moshiri
- From the Departments of Radiology (S.F., M.M., M.D.) and Pathology (C.L.F.), University of Washington Medical Center, 1959 NE Pacific St, Seattle, WA 98195; and Department of Radiology, Winthrop Radiology Associates, Mineola, NY (D.S.K.)
| | - Corinne L Fligner
- From the Departments of Radiology (S.F., M.M., M.D.) and Pathology (C.L.F.), University of Washington Medical Center, 1959 NE Pacific St, Seattle, WA 98195; and Department of Radiology, Winthrop Radiology Associates, Mineola, NY (D.S.K.)
| | - Douglas S Katz
- From the Departments of Radiology (S.F., M.M., M.D.) and Pathology (C.L.F.), University of Washington Medical Center, 1959 NE Pacific St, Seattle, WA 98195; and Department of Radiology, Winthrop Radiology Associates, Mineola, NY (D.S.K.)
| | - Manjiri Dighe
- From the Departments of Radiology (S.F., M.M., M.D.) and Pathology (C.L.F.), University of Washington Medical Center, 1959 NE Pacific St, Seattle, WA 98195; and Department of Radiology, Winthrop Radiology Associates, Mineola, NY (D.S.K.)
| |
Collapse
|
29
|
Moran M, Zombori G, Ryan J, Downey P, McAuliffe F. Is there a role for 3 dimensional power Doppler placental ultrasound and computerised assessment of calcification in post-term pregnancies? Radiography (Lond) 2016. [DOI: 10.1016/j.radi.2016.04.002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
30
|
Marr S, Ashton L, Stemm A, Cincotta R, Chua J, Duncombe G. Vasa praevia: ultrasound diagnosis at the mid-trimester scan. Australas J Ultrasound Med 2015; 16:8-15. [PMID: 28191166 PMCID: PMC5029979 DOI: 10.1002/j.2205-0140.2013.tb00091.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
Background: Vasa praevia is a condition in which fetal vessels, unsupported by the umbilical cord or placenta, run on the fetal membranes in the lower uterine segment near the cervix. Rupture of these vessels prior to or at the time of delivery is associated with a very high perinatal mortality rate. Antenatal diagnosis of this condition with ultrasound is readily available, alters management and significantly decreases the risk of fetal loss. Materials and methods: We describe our experience of diagnosing vasa praevia at a tertiary referral ultrasound centre. The ultrasound characteristics that led to the diagnosis of vasa praevia and associated risk factors will be discussed. A guide to aid sonographers when performing an obstetric examination to help screen for this condition has been included. Conclusions: Where suspicion of vasa praevia is raised, and cannot be ruled out on transvaginal ultrasound, a third trimester scan is required.
Collapse
Affiliation(s)
- Stefanie Marr
- Queensland Ultrasound for Women Brisbane Queensland Australia
| | - Lindsay Ashton
- Queensland Ultrasound for Women Brisbane Queensland Australia
| | - Annmarie Stemm
- Queensland Ultrasound for Women Brisbane Queensland Australia
| | - Robert Cincotta
- Queensland Ultrasound for Women BrisbaneQueenslandAustralia; University of Queensland St LuciaQueenslandAustralia; Department of Maternal Fetal Medicine Mater MothersHospital south BrisbaneQueenslandAustralia
| | - Jacqueline Chua
- Queensland Ultrasound for Women BrisbaneQueenslandAustralia; University of Queensland St LuciaQueenslandAustralia; Department of Maternal Fetal Medicine Mater MothersHospital south BrisbaneQueenslandAustralia
| | - Gregory Duncombe
- Queensland Ultrasound for Women BrisbaneQueenslandAustralia; University of Queensland St LuciaQueenslandAustralia; Department of Maternal Fetal MedicineRoyal Brisbane Women's Hospital HerstonQueenslandAustralia
| |
Collapse
|
31
|
Diagnostic prénatal du placenta accreta. IMAGERIE DE LA FEMME 2015. [DOI: 10.1016/j.femme.2015.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
32
|
Kozinszky Z, Surányi A, Péics H, Molnár A, Pál A. Placental Volumetry by 2-D Sonography with a New Mathematical Formula: Prospective Study on the Shell of a Spherical Sector Model. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:2252-2258. [PMID: 25959054 DOI: 10.1016/j.ultrasmedbio.2015.04.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2014] [Revised: 03/12/2015] [Accepted: 04/06/2015] [Indexed: 06/04/2023]
Abstract
The aim of this study was to determine the utility of a new mathematical model in volumetric assessment of the placenta using 2-D ultrasound. Placental volumetry was performed in a prospective cross-sectional survey by virtual organ computer-aided analysis (VOCAL) with the help of a shell-off method in 346 uncomplicated pregnancies according to STROBE (Strengthening the Reporting of Observational Studies in Epidemiology) guidelines. Furthermore, placental thickness, length and height were measured with the 2-D technique to estimate placental volume based on the mathematical formula for the volume of "the shell of the spherical sector." Fetal size was also assessed by 2-D sonography. The placental volumes measured by 2-D and 3-D techniques had a correlation of 0.86. In the first trimester, the correlation was 0.82, and later during pregnancy, it was 0.86. Placental volumetry using "the circle-shaped shell of the spherical sector" mathematical model with 2-D ultrasound technique may be introduced into everyday practice to screen for placental volume deviations associated with adverse pregnancy outcome.
Collapse
Affiliation(s)
- Zoltan Kozinszky
- Reproductive Medicine, Department of Obstetrics and Gynecology, Huddinge Karolinska University Hospital, Stockholm, Sweden.
| | - Andrea Surányi
- Department of Obstetrics and Gynecology, University of Szeged, Szeged, Hungary
| | - Hajnalka Péics
- Faculty of Civil Engineering, University of Novi Sad, Subotica, Serbia
| | - András Molnár
- Department of Obstetrics and Gynecology, University of Szeged, Szeged, Hungary
| | - Attila Pál
- Department of Obstetrics and Gynecology, University of Szeged, Szeged, Hungary
| |
Collapse
|
33
|
Epelman M, Merrow AC, Guimaraes CV, Victoria T, Calvo-Garcia MA, Kline-Fath BM. Extrafetal Findings on Fetal Magnetic Resonance Imaging: A Pictorial Essay. Semin Ultrasound CT MR 2015; 36:550-67. [PMID: 26614136 DOI: 10.1053/j.sult.2015.07.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
Although US is the mainstay of fetal imaging, magnetic resonance imaging (MRI) has become an invaluable adjunct in recent years. MRI offers superb soft tissue contrast that allows for detailed evaluation of fetal organs, particularly the brain, which enhances understanding of disease severity. MRI can yield results that are similar to or even better than those of US, particularly in cases of marked oligohydramnios, maternal obesity, or adverse fetal positioning. Incidentally detected extrafetal MRI findings are not uncommon and may affect clinical care. Physicians interpreting fetal MRI studies should be aware of findings occurring outside the fetus, including those structures important for the pregnancy. A systematic approach is necessary in the reading of such studies. This helps to ensure that important findings are not missed, appropriate clinical management is implemented, and unnecessary follow-up examinations are avoided. In this pictorial essay, the most common extrafetal abnormalities are described and illustrated.
Collapse
Affiliation(s)
- Monica Epelman
- Department of Medical Imaging/Radiology, Nemours Children׳s Hospital, Orlando, FL.
| | - Arnold C Merrow
- Department of Radiology, Cincinnati Children׳s Hospital Medical Center, Cincinnati, OH
| | | | - Teresa Victoria
- Department of Radiology, The Children׳s Hospital of Philadelphia, Philadelphia, PA
| | - Maria A Calvo-Garcia
- Department of Radiology, Cincinnati Children׳s Hospital Medical Center, Cincinnati, OH
| | - Beth M Kline-Fath
- Department of Radiology, Cincinnati Children׳s Hospital Medical Center, Cincinnati, OH
| |
Collapse
|
34
|
Miyake H, Miyazaki-Igarashi M, Suzuki S. Placenta with Old, Diffuse Infarction that Was Difficult to Differentiate from a Placental Tumor. J NIPPON MED SCH 2015; 82:156-8. [PMID: 26156670 DOI: 10.1272/jnms.82.156] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
Placental lesions, including placental infarction, are associated with fetal and neonatal mortality and morbidity. We present a case of fetal growth restriction associated with an old, diffuse placental infarction. Because the placenta had only a single viable cotyledon, the others being atrophic, the lesion appeared to be a placental tumor on prenatal ultrasonography. The patient did not have pregnancy-induced hypertension. At 31 weeks of gestation, a cesarean delivery was performed because of fetal growth arrest and breech presentation. A small-for-gestational age infant was delivered with Apgar scores of 8 at both 1 and 5 minutes, and the infant had cleft palate and cleft lips. Pathological examination of the placenta revealed an old, diffuse infarction without neoplastic change. In cases in which a placental tumor causing fetal growth restriction is strongly suspected, diffuse placental infarction should be considered as part of the differential diagnosis, because placental tumors are associated with poor maternal prognosis.
Collapse
|
35
|
Rheinboldt M, Delproposto Z. Sonography of placental abnormalities: a pictorial review. Emerg Radiol 2015; 22:401-8. [PMID: 25933509 DOI: 10.1007/s10140-015-1320-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2015] [Accepted: 04/16/2015] [Indexed: 10/23/2022]
Abstract
Often overlooked during routine ultrasound evaluation of a normal pregnancy, the placenta forms the biologic interface between the mother and fetus and is critical to fetal growth and development. Malformations in development, positioning, and vascularity can have profound implications for both maternal and fetal well-being. As such, a judicious inspection of the placenta is warranted as an integral part of every screening or emergent prenatal ultrasound. Herein, we present a pictorial review of a variety of placental pathologic conditions including abnormalities in positioning, adherence, vascularity, and hemorrhage as well as potential peri-placental masses and gestational trophoblastic disease, all of which are readily encountered in a busy emergency radiology practice.
Collapse
Affiliation(s)
- Matt Rheinboldt
- Department of Emergency Radiology, Henry Ford Hospital, Detroit, MI, USA,
| | | |
Collapse
|
36
|
Mayhew T. Morphomics: An integral part of systems biology of the human placenta. Placenta 2015; 36:329-40. [DOI: 10.1016/j.placenta.2015.01.001] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/28/2014] [Revised: 01/05/2015] [Accepted: 01/07/2015] [Indexed: 01/03/2023]
|
37
|
Andescavage NN, DuPlessis A, Limperopoulos C. Advanced MR imaging of the placenta: Exploring the in utero placenta-brain connection. Semin Perinatol 2015; 39:113-23. [PMID: 25765905 PMCID: PMC4409865 DOI: 10.1053/j.semperi.2015.01.004] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
Abstract
The placenta is a vital organ necessary for the healthy neurodevelopment of the fetus. Despite the known associations between placental dysfunction and neurologic impairment, there is a paucity of tools available to reliably assess in vivo placental health and function. Existing clinical tools for placental assessment remain insensitive in predicting and evaluating placental well-being. Advanced MRI techniques hold significant promise for the dynamic, non-invasive, real-time assessment of placental health and identification of early placental-based disorders. In this review, we summarize the available clinical tools for placental assessment, including ultrasound, Doppler, and conventional MRI. We then explore the emerging role of advanced placental MR imaging techniques for supporting the developing fetus and appraise the strengths and limitations of quantitative MRI in identifying early markers of placental dysfunction for improved pregnancy monitoring and fetal outcomes.
Collapse
Affiliation(s)
- Nickie Niforatos Andescavage
- Division of Neonatology, Children’s National Health System, 111
Michigan Ave. NW, Washington, DC 20010,Fetal & Transitional Medicine, Children’s National Health
System, 111 Michigan Ave. NW, Washington, DC 20010,Department of Pediatrics, George Washington University School of Medicine,
2300 Eye St. NW, Washington, DC 20037
| | - Adre DuPlessis
- Fetal & Transitional Medicine, Children’s National Health
System, 111 Michigan Ave. NW, Washington, DC 20010,Diagnostic Imaging & Radiology, Children’s National Health
System, 111 Michigan Ave. NW, Washington, DC 20010,Department of Pediatrics, George Washington University School of Medicine,
2300 Eye St. NW, Washington, DC 20037
| | - Catherine Limperopoulos
- Division of Neonatology, Children's National Health System, 111 Michigan Ave. NW, Washington, DC 20010; Division of Fetal and Transitional Medicine, Children's National Health System, 111 Michigan Ave. NW, Washington, DC 20010; Department of Pediatrics, George Washington University School of Medicine, 2300 Eye St. NW, Washington, DC 20037; Division of Diagnostic Imaging and Radiology, Children's National Health System, 111 Michigan Ave. NW, Washington, DC 20010; Division of Radiology, George Washington University School of Medicine, 2300 Eye St. NW, Washington, DC 20037.
| |
Collapse
|
38
|
Torricelli M, Vannuccini S, Moncini I, Cannoni A, Voltolini C, Conti N, Di Tommaso M, Severi FM, Petraglia F. Anterior placental location influences onset and progress of labor and postpartum outcome. Placenta 2014; 36:463-6. [PMID: 25573094 DOI: 10.1016/j.placenta.2014.12.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Revised: 12/15/2014] [Accepted: 12/18/2014] [Indexed: 11/19/2022]
Abstract
INTRODUCTION The aim of the study is to evaluate whether placental location at term is associated with delivery outcome. METHODS A prospective study including 2354 patients with singleton pregnancy at term admitted for vaginal delivery was conducted. Placental position was determined before delivery by ultrasonographic examination performed transabdominally with women in the supine position. Maternal characteristics and delivery outcome such as premature rupture of membranes, induction of labor, mode and gestational age at delivery, indication for cesarean section, duration of the third stage, postpartum hemorrhage (PPH) and manual removal of placenta were correlated with anterior, posterior or fundal placental locations. RESULTS Among women enrolled: i) 1164 had an anterior placenta, ii) 1087 a posterior placenta, iii) 103 a fundal placenta. Women with anterior placenta showed: i) a higher incidence of induction of labor (p = 0.0001), especially for postdate pregnancies and prolonged prelabor rupture of membranes (p < 0.0001), ii) a higher rate of cesarean section rate for failure to progress in labor (p = 0.02), iii) a prolonged third stage (p = 0.01), iv) a higher incidence of manual removal of placenta (p = 0.003) and a higher rate of PPH in vaginal deliveries (p = 0.02). DISCUSSION The present study showed the influence of anterior placental location on the course of labor, with a later onset of labor, a higher rate of induction and cesarean section and postpartum complications. The reason for this influence on labor and delivery complications remains to be elucidated.
Collapse
MESH Headings
- Adult
- Cesarean Section/adverse effects
- Female
- Fetal Membranes, Premature Rupture/epidemiology
- Fetal Membranes, Premature Rupture/etiology
- Fetal Membranes, Premature Rupture/therapy
- Gestational Age
- Hospitals, University
- Humans
- Incidence
- Italy/epidemiology
- Labor, Induced/adverse effects
- Obstetric Labor Complications/epidemiology
- Obstetric Labor Complications/etiology
- Obstetric Labor Complications/therapy
- Placenta/diagnostic imaging
- Postpartum Hemorrhage/epidemiology
- Postpartum Hemorrhage/etiology
- Postpartum Hemorrhage/therapy
- Pregnancy
- Pregnancy Outcome
- Pregnancy, Angular/diagnostic imaging
- Pregnancy, Angular/physiopathology
- Pregnancy, Angular/therapy
- Pregnancy, Prolonged/epidemiology
- Pregnancy, Prolonged/etiology
- Pregnancy, Prolonged/therapy
- Prospective Studies
- Ultrasonography, Prenatal
- Young Adult
Collapse
Affiliation(s)
- M Torricelli
- Department of Molecular and Developmental Medicine, University of Siena, Siena, Italy
| | - S Vannuccini
- Department of Molecular and Developmental Medicine, University of Siena, Siena, Italy
| | - I Moncini
- Department of Molecular and Developmental Medicine, University of Siena, Siena, Italy
| | - A Cannoni
- Department of Molecular and Developmental Medicine, University of Siena, Siena, Italy
| | - C Voltolini
- Department of Molecular and Developmental Medicine, University of Siena, Siena, Italy
| | - N Conti
- Department of Molecular and Developmental Medicine, University of Siena, Siena, Italy
| | - M Di Tommaso
- Department of Health Sciences, University of Florence, Florence, Italy
| | - F M Severi
- Department of Molecular and Developmental Medicine, University of Siena, Siena, Italy
| | - F Petraglia
- Department of Molecular and Developmental Medicine, University of Siena, Siena, Italy.
| |
Collapse
|
39
|
Fang SW, Ou CY, Tsai CC, Fu HC, Cheng HH, Cheng BH, Chang MS, Hsu TY. Second-trimester placental volume and vascular indices in the prediction of small-for-gestational-age neonates. Fetal Diagn Ther 2014; 37:123-8. [PMID: 25359105 DOI: 10.1159/000365148] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/20/2014] [Accepted: 06/07/2014] [Indexed: 11/19/2022]
Abstract
OBJECTIVE To evaluate the ability of second-trimester placental volume and vascular indices to predict small-for-gestational-age (SGA) birth weight pregnancies. MATERIAL AND METHODS Women with singleton pregnancies were prospectively evaluated at 17-20 weeks of gestation. Second-trimester placental volume and vascular indices were obtained and calculated using volume organ computer-aided analysis and three-dimensional (3D) power Doppler ultrasound. Participants were followed until delivery and their medical records were reviewed, including maternal age, parity and pregestational body weight and body height, as well as the gestational age, birth weight and gender of the fetus. RESULTS Of the 163 women with complete follow-up, 20 gave birth to SGA and 143 to appropriate-for-gestational-age (AGA) neonates. The mean second-trimester placental volume was significantly lower in the SGA than in the AGA group (170.6 ± 49.8 vs. 213.5 ± 75.8 cm(3), p = 0.015). None of the vascular indices, including the vascularization index, flow index and vascularization flow index, differed significantly between the two groups. We also found that the optimum cutoff for placental volume at a gestational age of 17-18 weeks was 189.7 cm(3). DISCUSSION Second-trimester placental volume was positively correlated with neonatal birth weight. Second-trimester placental volume measured on 3D ultrasound may be predictive of SGA neonates.
Collapse
Affiliation(s)
- Shih-Wen Fang
- Department of Obstetrics and Gynecology, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Chiayi, Taiwan, ROC
| | | | | | | | | | | | | | | |
Collapse
|
40
|
3D Power Doppler ultrasound and computerised placental assessment in normal pregnancy. Radiography (Lond) 2014. [DOI: 10.1016/j.radi.2014.01.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
41
|
Surányi A, Kozinszky Z, Molnár A, Nyári T, Bitó T, Pál A. Placental three-dimensional power Doppler indices in mid-pregnancy and late pregnancy complicated by gestational diabetes mellitus. Prenat Diagn 2013; 33:952-8. [DOI: 10.1002/pd.4172] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/25/2013] [Revised: 05/23/2013] [Accepted: 05/31/2013] [Indexed: 11/10/2022]
Affiliation(s)
- A. Surányi
- Department of Obstetrics and Gynecology; University of Szeged; 1, Semmelweis u H-6725 Szeged Hungary
| | - Z. Kozinszky
- Department of Obstetrics and Gynecology; Blekinge Hospital; Kvinnokliniken, Blekinge Sjukhuset 371 81 Karlskrona Sweden
| | - A. Molnár
- Department of Obstetrics and Gynecology; University of Szeged; 1, Semmelweis u H-6725 Szeged Hungary
| | - T. Nyári
- Department of Medical Physics and Informatics; University of Szeged; 9, Korányi fasor H-6720 Szeged Hungary
| | - T. Bitó
- Department of Obstetrics and Gynecology; University of Szeged; 1, Semmelweis u H-6725 Szeged Hungary
| | - A. Pál
- Department of Obstetrics and Gynecology; University of Szeged; 1, Semmelweis u H-6725 Szeged Hungary
| |
Collapse
|
42
|
Moran M, Higgins M, Zombori G, Ryan J, McAuliffe FM. Computerized assessment of placental calcification post-ultrasound: a novel software tool. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2013; 41:545-549. [PMID: 22858982 DOI: 10.1002/uog.12278] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 07/17/2012] [Indexed: 06/01/2023]
Abstract
OBJECTIVES Placental calcification is associated with an increased risk of perinatal morbidity and mortality. The subjectivity of current ultrasound methods of assessment of placental calcification indicates that a more objective method is required. The aim of this study was to correlate the percentage of calcification defined by the clinician using a new software tool for calculating the extent of placental calcification with traditional ultrasound methods and with pregnancy outcome. METHODS Ninety placental images were individually assessed. An upper threshold was defined, based on high intensity, to quantify calcification within the placenta. Output metrics were then produced including the overall percentage of calcification with respect to the total number of pixels within the region of interest. The results were correlated with traditional ultrasound methods of assessment of placental calcification and with pregnancy outcome. RESULTS The results demonstrate a significant correlation between placental calcification, as defined using the software, and traditional methods of Grannum grading of placental calcification. Whilst correlation with perinatal outcome and cord pH was not significant as a result of small numbers, patients with placental calcification assessed using the computerized software at the upper quartile had higher rates of poor perinatal outcome when compared with those at the lower quartile (8/22 (36%) vs 3/23 (13%); P = 0.069). CONCLUSION These results suggest that this computerized software tool has the potential to become an alternative method of assessing placental calcification.
Collapse
Affiliation(s)
- M Moran
- Diagnostic Imaging, School of Medicine and Medical Science, University College Dublin, Dublin 2, Ireland
| | | | | | | | | |
Collapse
|
43
|
Al-Saleh I, Alsabbahen A, Shinwari N, Billedo G, Mashhour A, Al-Sarraj Y, Mohamed GED, Rabbah A. Polycyclic aromatic hydrocarbons (PAHs) as determinants of various anthropometric measures of birth outcome. THE SCIENCE OF THE TOTAL ENVIRONMENT 2013; 444:565-78. [PMID: 23314068 DOI: 10.1016/j.scitotenv.2012.12.021] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/27/2012] [Revised: 12/08/2012] [Accepted: 12/09/2012] [Indexed: 05/25/2023]
Abstract
Polycyclic aromatic hydrocarbons (PAHs) are ubiquitous environmental contaminants that are known to induce oxidative stress. There have been several reports about the link between PAH exposure and complications in pregnancy. This cross-sectional study was conducted to: (1) measure the levels of benzo(a)anthracene (BaA), chrysene (Ch), benzo(b)fluoranthene (BbF), benzo(a)pyrene (BaP), and dibenzo(a,h)anthracene (DBahA) in placentas and maternal and -umbilical cord blood obtained at delivery from 1578 women between June 2005 and 2006 in the area of Al-Kharj, Saudi Arabia; (2) assess their influence on various anthropometric measures of birth outcome taking into consideration the carcinogenic properties of these PAHs; and (3) determine the degree of PAH-related oxidative DNA damage and birth outcome. Among the five tested PAHs, only BaP was carcinogenic; therefore, the levels of the other four probable or possible carcinogenic PAHs (BaA, Ch, BaF, and DBahA) were summed as ∑4-PAHs. Levels of 1-hydroxypyrene (1-HP) were determined in maternal urine samples as a biomarker of PAH internal dose. Urinary cotinine (COT) was measured as an index of smoking. The following markers of oxidative stress were selected: malondialdehyde (MDA) in cord (C-MDA) and maternal (M-MDA) serum and 8-hydroxy-2-deoxyguanosine (8-OHdG) in maternal urine. None of the tested PAHs was found in maternal or cord blood. However, all five PAH compounds were detected in placentas; Ch was the highest (6.582 μg/kg dry wt.), and BaA was the lowest (0.236 μg/kg dry wt.). The mean concentration of urinary 1-HP found in this study was 0.216 ± 0.856 μg/g Cr. After adjusting for gestational age and other confounding variables, regression models revealed an inverse relationship between placental weight, cord length and placental BaP. A similar trend was observed between cord length and ∑4-PAHs in placental tissues. Urinary 1-HP, though, cannot be used as an unequivocal biomarker of PAH exposure, but it can be an appropriate indicator of exposure to environmental tobacco smoke (ETS). The data demonstrate that ETS exposure (as measured by urinary COT) may adversely affect birth outcome as shown by reduced head circumference, birth weight, and birth length, as well as increased cephalization index. The positive relationship between 8-OHdG levels and 1-HP in urine provides evidence of an oxidative stress mechanism. Although this study provides no direct evidence of an association between PAH exposure and DNA damage, increased oxidative stress in the form of lipid peroxidation significantly affected various birth measures. Therefore, there is a need for studies regarding PAH exposure and its associated biological effects to determine the extent of potential fetal damage as well as possible long-term effects, such as cancer.
Collapse
Affiliation(s)
- Iman Al-Saleh
- Environmental Health Section, Biological & Medical Research Department, King Faisal Specialist Hospital & Research Centre, PO Box: 3354, Riyadh, Saudi Arabia.
| | | | | | | | | | | | | | | |
Collapse
|
44
|
Antsaklis A, Antsaklis P, Natsis S. Three-dimensional Evaluation of the Placenta: Review of the Literature. ACTA ACUST UNITED AC 2013. [DOI: 10.5005/jp-journals-10009-1272] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
ABSTRACT
The introduction of the three-dimensional (3D) ultrasound made feasible the quantitative and qualitative evaluation of the placenta's characteristics like the volume, the surface rendered imaging, the vascularization and the blood flow. These novel techniques may assist the early detection of pregnancies at high risk for fetal growth restriction (FGR), pre-eclampsia (PET) and pregnancy-induced hypertension (PIH) and help clinicians to detect pregnancies at risk earlier and to assess new therapeutic strategies in order to prevent adverse pregnancy outcomes. However, in this new technique there are still limitations regarding the assessment of the placenta employing 3D ultrasound in everyday clinical practice. In the following article, we perform a review of the literature regarding the importance of 3D evaluation of the placenta in pregnancy.
How to cite this article
Natsis S, Antsaklis P, Antsaklis A, Kurjak A. Three-dimensional Evaluation of the Placenta: Review of the Literature. Donald School J Ultrasound Obstet Gynecol 2013;7(1):73-79.
Collapse
|
45
|
Nguyen D, Nguyen C, Yacobozzi M, Bsat F, Rakita D. Imaging of the Placenta with Pathologic Correlation. Semin Ultrasound CT MR 2012; 33:65-77. [DOI: 10.1053/j.sult.2011.10.003] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
46
|
Abstract
ABSTRACT
In recent years, transvaginal evaluation of the placenta has completely changed the way obstetricians need to perceive and assess a low-lying placenta. Additionally, the number of negative ultrasound examinations in morbid placental adherence has reduced. This article presents the evidence on the safety and accuracy of transvaginal placental evaluation and goes on to discuss the manner in which transvaginal findings should alter clinical protocols to optimize maternal and fetal outcomes. It also answers a very pertinent clinical question: How low is low?
How to cite this article
Khurana A. Placenta and Transvaginal Sonography. Donald School J Ultrasound Obstet Gynecol 2012;6(4):391-397.
Collapse
|
47
|
Khankin EV, Hacker MR, Zelop CM, Karumanchi SA, Rana S. Intravital high-frequency ultrasonography to evaluate cardiovascular and uteroplacental blood flow in mouse pregnancy. Pregnancy Hypertens 2011; 2:84-92. [PMID: 22544045 PMCID: PMC3337859 DOI: 10.1016/j.preghy.2011.11.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/14/2022]
Abstract
OBJECTIVE: The objective of this study is to define the ultrasonographic changes in the cardiovascular and uteroplacental circulation of normal pregnant mice compared to non-pregnant mice using high-frequency, high-resolution ultrasonography. METHODS: Ten to twelve-week-old CD-1 mice (six non-pregnant and six pregnant animals) were used for all experiments. Vevo® 2100 (VisualSonics) was used to evaluate the cardiovascular and uteroplacental circulation physiology. Cardiac echocardiogram and uterine artery Doppler studies were performed on all animals. Pregnant animals were evaluated on embryonic day seven (E7), thirteen (E13) and eighteen (E18). Fetal heart rate and umbilical artery Doppler flows were obtained on pregnant animals. Three-dimensional ultrasonography imaging was utilized for quantification of placental volumes. All data are presented as median {10(th)-90(th) percentiles}. RESULTS: In pregnant mice on E7 compared to non-pregnant mice, there was an increase in cardiac output (p=0.008), stroke volume (p=0.002), ejection fraction, (p=0.02) and fractional shortening (p=0.02). The maternal heart rate increased throughout gestation (p= 0.009). During pregnancy, a gestational sac was clearly visible on E7. Between E13 and E18, the fetal size and fetal heart rate increased (p=0.001) and the umbilical artery peak systolic velocity increased (p <0.001). Minimal diastolic blood flow was observed in the umbilical artery on E13, which increased slightly on day E18 (p=0.01). There was also no change in the uterine artery resistance index between non-pregnant and pregnant mice. The placental volume increased between E13 and E18 (p=0.03). CONCLUSION: Several changes noted in cardiovascular and uteroplacental systems occurring during normal murine pregnancy have striking similarities to humans and can be accurately measured using newer ultrasonographic techniques. Further studies are needed to evaluate changes in these vascular beds in mouse models of diseases such as preeclampsia and intrauterine growth restriction.
Collapse
Affiliation(s)
- Eliyahu V Khankin
- Department of Medicine/Division of Nephrology, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | | | | | | | | |
Collapse
|
48
|
Victoria T, Johnson AM, Kramer SS, Coleman B, Bebbington M, Epelman M. Extrafetal findings at fetal MR: evaluation of the normal placenta and correlation with ultrasound. Clin Imaging 2011; 35:371-7. [DOI: 10.1016/j.clinimag.2010.08.018] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2010] [Accepted: 08/24/2010] [Indexed: 11/29/2022]
|
49
|
Comparative analysis of placental vasculature and placental volume in normal and IUGR pregnancies with the use of three-dimensional Power Doppler. Arch Gynecol Obstet 2011; 285:331-7. [PMID: 21744006 PMCID: PMC3257431 DOI: 10.1007/s00404-011-1968-9] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2011] [Accepted: 06/21/2011] [Indexed: 11/19/2022]
Abstract
Objectives To evaluate the differences in placental vascular indices and placental volume between normal and IUGR pregnancies. Methods A prospective study was conducted on a group of 100 normal and 20 IUGR pregnancies between 22 and 42 weeks of gestation. For the purpose of evaluation of placental volume and placental vascular indices, we applied 3D Power Doppler and VOCAL technique. Only patients with entirely visualized placenta were included in the study. Results A comparative analysis of vascularization index (VI), vascularization flow index (VFI), flow index (FI), and placental volume (PV) revealed statistically significant differences between normal and IUGR pregnancies. In normal pregnancies, the volume of the placenta was on average 92.42 cm3 larger than in pregnancies complicated by IUGR. Receiver operating characteristic (ROC) curves were used to evaluate the clinical usefulness of placental vascular indices and placental volume for discriminating IUGR and normal pregnancies. It was concluded that the VI, VFI, PV, FI parameters are the best discriminants, with the cut-off values of 5.30, 2.30, 199, and 36.0, respectively. Conclusions The quantitative assessment of placental vasculature and placental volume by means of 3D Power Doppler and VOCAL technique is an adjunctive modality for differentiation between normal and IUGR pregnancies. Our findings further suggest that the vascularization index (VI) and vascularization flow index (VFI) are the best parameters with the most favorable discriminating potential for proper identification of IUGR pregnancies.
Collapse
|
50
|
Bonel HM, Stolz B, Diedrichsen L, Frei K, Saar B, Tutschek B, Raio L, Surbek D, Srivastav S, Nelle M, Slotboom J, Wiest R. Diffusion-weighted MR imaging of the placenta in fetuses with placental insufficiency. Radiology 2011; 257:810-9. [PMID: 21084415 DOI: 10.1148/radiol.10092283] [Citation(s) in RCA: 84] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To evaluate diffusion-weighted magnetic resonance (MR) imaging of the human placenta in fetuses with and fetuses without intrauterine growth restriction (IUGR) who were suspected of having placental insufficiency. MATERIALS AND METHODS The study was approved by the local ethics committee, and written informed consent was obtained. The authors retrospectively evaluated 1.5-T fetal MR images from 102 singleton pregnancies (mean gestation ± standard deviation, 29 weeks ± 5; range, 21-41 weeks). Morphologic and diffusion-weighted MR imaging were performed. A region of interest analysis of the apparent diffusion coefficient (ADC) of the placenta was independently performed by two observers who were blinded to clinical data and outcome. Placental insufficiency was diagnosed if flattening of the growth curve was detected at obstetric ultrasonography (US), if the birth weight was in the 10th percentile or less, or if fetal weight estimated with US was below the 10th percentile. Abnormal findings at Doppler US of the umbilical artery and histopathologic examination of specimens from the placenta were recorded. The ADCs in fetuses with placental insufficiency were compared with those in fetuses of the same gestational age without placental insufficiency and tested for normal distribution. The t tests and Pearson correlation coefficients were used to compare these results at 5% levels of significance. RESULTS Thirty-three of the 102 pregnancies were ultimately categorized as having an insufficient placenta. MR imaging depicted morphologic changes (eg, infarction or bleeding) in 27 fetuses. Placental dysfunction was suspected in 33 fetuses at diffusion-weighted imaging (mean ADC, 146.4 sec/mm(2) ± 10.63 for fetuses with placental insufficiency vs 177.1 sec/mm(2) ± 18.90 for fetuses without placental insufficiency; P < .01, with one false-positive case). The use of diffusion-weighted imaging in addition to US increased sensitivity for the detection of placental insufficiency from 73% to 100%, increased accuracy from 91% to 99%, and preserved specificity at 99%. CONCLUSION Placental dysfunction associated with growth restriction is associated with restricted diffusion and reduced ADC. A decreased ADC used as an early marker of placental damage might be indicative of pregnancy complications such as IUGR. SUPPLEMENTAL MATERIAL http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.10092283/-/DC1.
Collapse
Affiliation(s)
- Harald Marcel Bonel
- Institute for Diagnostic, Interventional and Pediatric Radiology, Inselspital, University of Bern, Freiburgstrasse 10, 3010 Bern, Switzerland.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|