1
|
Minervini M, Mergy M, Zhu Y, Gutierrez Diaz MA, Pointer C, Shinkazh O, Oppenheim SF, Cramer SM, Przybycien TM, Zydney AL. Continuous precipitation-filtration process for initial capture of a monoclonal antibody product using a four-stage countercurrent hollow fiber membrane washing step. Biotechnol Bioeng 2024; 121:2258-2268. [PMID: 37565527 PMCID: PMC10858288 DOI: 10.1002/bit.28525] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 07/27/2023] [Accepted: 07/29/2023] [Indexed: 08/12/2023]
Abstract
The significant increase in product titers, coupled with the growing focus on continuous bioprocessing, has renewed interest in using precipitation as a low-cost alternative to Protein A chromatography for the primary capture of monoclonal antibody (mAb) products. In this work, a commercially relevant mAb was purified from clarified cell culture fluid using a tubular flow precipitation reactor with dewatering and washing provided by tangential flow microfiltration. The particle morphology was evaluated using an inline high-resolution optical probe, providing quantitative data on the particle size distribution throughout the precipitation process. Data were obtained in both a lab-built 2-stage countercurrent washing system and a commercial countercurrent contacting skid that provided 4 stages of continuous washing. The processes were operated continuously for 2 h with overall mAb yield of 92 ± 3% and DNA removal of nearly 3 logs in the 4-stage system. The high DNA clearance was achieved by selective redissolution of the mAb using a low pH acetate buffer. Host cell protein clearance was 0.59 ± 0.08 logs, comparable to that based on model predictions. The process mass intensity was slightly better than typical Protein A processes and could be significantly improved by preconcentration of the antibody feed material.
Collapse
Affiliation(s)
- Mirko Minervini
- Department of Chemical Engineering, The Pennsylvania State University, State College, Pennsylvania, USA
| | - Matthew Mergy
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Yuncan Zhu
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Mario A Gutierrez Diaz
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA
| | | | | | | | - Steven M Cramer
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Todd M Przybycien
- Department of Chemical and Biological Engineering, Rensselaer Polytechnic Institute, Troy, New York, USA
| | - Andrew L Zydney
- Department of Chemical Engineering, The Pennsylvania State University, State College, Pennsylvania, USA
| |
Collapse
|
2
|
Dietrich A, Schiemer R, Kurmann J, Zhang S, Hubbuch J. Raman-based PAT for VLP precipitation: systematic data diversification and preprocessing pipeline identification. Front Bioeng Biotechnol 2024; 12:1399938. [PMID: 38882637 PMCID: PMC11177211 DOI: 10.3389/fbioe.2024.1399938] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/12/2024] [Accepted: 05/13/2024] [Indexed: 06/18/2024] Open
Abstract
Virus-like particles (VLPs) are a promising class of biopharmaceuticals for vaccines and targeted delivery. Starting from clarified lysate, VLPs are typically captured by selective precipitation. While VLP precipitation is induced by step-wise or continuous precipitant addition, current monitoring approaches do not support the direct product quantification, and analytical methods usually require various, time-consuming processing and sample preparation steps. Here, the application of Raman spectroscopy combined with chemometric methods may allow the simultaneous quantification of the precipitated VLPs and precipitant owing to its demonstrated advantages in analyzing crude, complex mixtures. In this study, we present a Raman spectroscopy-based Process Analytical Technology (PAT) tool developed on batch and fed-batch precipitation experiments of Hepatitis B core Antigen VLPs. We conducted small-scale precipitation experiments providing a diversified data set with varying precipitation dynamics and backgrounds induced by initial dilution or spiking of clarified Escherichia coli-derived lysates. For the Raman spectroscopy data, various preprocessing operations were systematically combined allowing the identification of a preprocessing pipeline, which proved to effectively eliminate initial lysate composition variations as well as most interferences attributed to precipitates and the precipitant present in solution. The calibrated partial least squares models seamlessly predicted the precipitant concentration with R 2 of 0.98 and 0.97 in batch and fed-batch experiments, respectively, and captured the observed precipitation trends with R 2 of 0.74 and 0.64. Although the resolution of fine differences between experiments was limited due to the observed non-linear relationship between spectral data and the VLP concentration, this study provides a foundation for employing Raman spectroscopy as a PAT sensor for monitoring VLP precipitation processes with the potential to extend its applicability to other phase-behavior dependent processes or molecules.
Collapse
Affiliation(s)
- Annabelle Dietrich
- Institute of Process Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Robin Schiemer
- Institute of Process Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Jasper Kurmann
- Institute of Process Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Shiqi Zhang
- Institute of Process Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| | - Jürgen Hubbuch
- Institute of Process Engineering in Life Sciences, Section IV: Biomolecular Separation Engineering, Karlsruhe Institute of Technology (KIT), Karlsruhe, Germany
| |
Collapse
|
3
|
Pons Royo MDC, Beulay JL, Valery E, Jungbauer A, Satzer P. Design of millidevices to expedite apparent solubility measurements. REACT CHEM ENG 2022. [DOI: 10.1039/d2re00022a] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
A fast, automated and accurate millidevice for determination of the apparent solubility of proteins and impurities and different industrially relevant precipitating agents.
Collapse
Affiliation(s)
- Maria del Carme Pons Royo
- Department of Innovation, Novasep, 81 Boulevard de la Moselle, 54340 Pompey, France
- Department of Biotechnology, University of Natural Resources and Life Sciences Vienna, 1190 Vienna, Austria
- Austrian Centre of Industrial Biotechnology (ACIB), Muthgasse 18, 1190 Vienna, Austria
| | - Jean-Luc Beulay
- Department of Innovation, Novasep, 81 Boulevard de la Moselle, 54340 Pompey, France
| | - Eric Valery
- Department of Innovation, Novasep, 81 Boulevard de la Moselle, 54340 Pompey, France
| | - Alois Jungbauer
- Department of Biotechnology, University of Natural Resources and Life Sciences Vienna, 1190 Vienna, Austria
- Austrian Centre of Industrial Biotechnology (ACIB), Muthgasse 18, 1190 Vienna, Austria
| | - Peter Satzer
- Department of Biotechnology, University of Natural Resources and Life Sciences Vienna, 1190 Vienna, Austria
| |
Collapse
|
4
|
São Pedro MN, Silva TC, Patil R, Ottens M. White paper on high-throughput process development for integrated continuous biomanufacturing. Biotechnol Bioeng 2021; 118:3275-3286. [PMID: 33749840 PMCID: PMC8451798 DOI: 10.1002/bit.27757] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 01/15/2021] [Accepted: 03/12/2021] [Indexed: 12/25/2022]
Abstract
Continuous manufacturing is an indicator of a maturing industry, as can be seen by the example of the petrochemical industry. Patent expiry promotes a price competition between manufacturing companies, and more efficient and cheaper processes are needed to achieve lower production costs. Over the last decade, continuous biomanufacturing has had significant breakthroughs, with regulatory agencies encouraging the industry to implement this processing mode. Process development is resource and time consuming and, although it is increasingly becoming less expensive and faster through high-throughput process development (HTPD) implementation, reliable HTPD technology for integrated and continuous biomanufacturing is still lacking and is considered to be an emerging field. Therefore, this paper aims to illustrate the major gaps in HTPD and to discuss the major needs and possible solutions to achieve an end-to-end Integrated Continuous Biomanufacturing, as discussed in the context of the 2019 Integrated Continuous Biomanufacturing conference. The current HTPD state-of-the-art for several unit operations is discussed, as well as the emerging technologies which will expedite a shift to continuous biomanufacturing.
Collapse
Affiliation(s)
| | - Tiago C. Silva
- Department of BiotechnologyDelft University of TechnologyDelftThe Netherlands
| | - Rohan Patil
- Global CMC DevelopmentSanofiFraminghamMassachusettsUSA
| | - Marcel Ottens
- Department of BiotechnologyDelft University of TechnologyDelftThe Netherlands
| |
Collapse
|
5
|
Rathore AS, Nikita S, Thakur G, Deore N. Challenges in process control for continuous processing for production of monoclonal antibody products. Curr Opin Chem Eng 2021. [DOI: 10.1016/j.coche.2021.100671] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
6
|
Gerstweiler L, Bi J, Middelberg AP. Continuous downstream bioprocessing for intensified manufacture of biopharmaceuticals and antibodies. Chem Eng Sci 2021. [DOI: 10.1016/j.ces.2020.116272] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
7
|
Martinez M, Spitali M, Norrant EL, Bracewell DG. Precipitation as an Enabling Technology for the Intensification of Biopharmaceutical Manufacture. Trends Biotechnol 2018; 37:237-241. [PMID: 30316558 DOI: 10.1016/j.tibtech.2018.09.001] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2018] [Revised: 08/31/2018] [Accepted: 09/11/2018] [Indexed: 12/27/2022]
Abstract
Advances in precipitation have demonstrated the capability of purifying therapeutic proteins such as antibodies from biological sources in a scalable and cost-effective manner. We discuss the latest developments in the unit operation for downstream processing applications and provide a perspective on exploring precipitation for bioprocess intensification.
Collapse
Affiliation(s)
- Michael Martinez
- Department of Biochemical Engineering, University College London, London WC1E 6BT, UK
| | | | | | - Daniel G Bracewell
- Department of Biochemical Engineering, University College London, London WC1E 6BT, UK.
| |
Collapse
|
8
|
P Radhakrishnan AN, Marques MPC, Davies MJ, O'Sullivan B, Bracewell DG, Szita N. Flocculation on a chip: a novel screening approach to determine floc growth rates and select flocculating agents. LAB ON A CHIP 2018; 18:585-594. [PMID: 29345271 DOI: 10.1039/c7lc00793k] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Flocculation is a key purification step in cell-based processes for the food and pharmaceutical industry where the removal of cells and cellular debris is aided by adding flocculating agents. However, finding the best suited flocculating agent and optimal conditions to achieve rapid and effective flocculation is a non-trivial task. In conventional analytical systems, turbulent mixing creates a dynamic equilibrium between floc growth and breakage, constraining the determination of floc formation rates. Furthermore, these systems typically rely on end-point measurements only. We have successfully developed for the first time a microfluidic system for the study of flocculation under well controlled conditions. In our microfluidic device (μFLOC), floc sizes and growth rates were monitored in real time using high-speed imaging and computational image analysis. The on-line and in situ detection allowed quantification of floc sizes and their growth kinetics. This eliminated the issues of sample handling, sample dispersion, and end-point measurements. We demonstrated the power of this approach by quantifying the growth rates of floc formation under forty different growth conditions by varying industrially relevant flocculating agents (pDADMAC, PEI, PEG), their concentration and dosage. Growth rates between 12.2 μm s-1 for a strongly cationic flocculant (pDADMAC) and 0.6 μm s-1 for a non-ionic flocculant (PEG) were observed, demonstrating the potential to rank flocculating conditions in a quantitative way. We have therefore created a screening tool to efficiently compare flocculating agents and rapidly find the best flocculating condition, which will significantly accelerate early bioprocess development.
Collapse
Affiliation(s)
- Anand N P Radhakrishnan
- Department of Biochemical Engineering, University College London, Bernard Katz Building, Gordon Street, London WC1H 0AH, UK.
| | | | | | | | | | | |
Collapse
|