1
|
Electron Paramagnetic Resonance (EPR) Biodosimetry with Human Teeth: A Crucial Technique for Acute and Chronic Exposure Assessment. HEALTH PHYSICS 2024; 126:322-338. [PMID: 38526251 DOI: 10.1097/hp.0000000000001822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/26/2024]
Abstract
ABSTRACT Radiation exposure is a primary concern in emergency response scenarios and long-term health assessments. Accurate quantification of radiation doses is critical for informed decision-making and patient care. This paper reviews the dose reconstruction technique using both X- and Q-bands, with tooth enamel as a reliable dosimeter. Tooth enamel, due to its exceptional resistance to alteration over time, offers a unique opportunity for assessing both acute and chronic radiation exposures. This review delves into the principles underlying enamel dosimetry, the mechanism of radiation interactions, and dose retention in tooth enamel. We explore state-of-the-art analytical methods, such as electron paramagnetic resonance (EPR) spectroscopy, that accurately estimate low and high doses in acute and chronic exposure. Furthermore, we discuss the applicability of tooth enamel dosimetry in various scenarios, ranging from historical radiological incidents to recent nuclear events or radiological incidents. The ability to reconstruct radiation doses from dental enamel provides a valuable tool for epidemiological studies, validating the assessment of health risks associated with chronic exposures and aiding in the early detection and management of acute radiation incidents. This paper underscores the significance of tooth enamel as an essential medium for radiation dose reconstruction and its broader implications for enhancing radiation protection, emergency response, and public health preparedness. Incorporating enamel EPR dosimetry into standard protocols has the potential to transform the field of radiation assessment, ensuring more accurate and timely evaluations of radiation exposure and its associated risks.
Collapse
|
2
|
SEED: An Operational Numerical Tool for Dosimetric Reconstruction in Case of External Radiological Overexposure. HEALTH PHYSICS 2022; 122:271-290. [PMID: 34995220 DOI: 10.1097/hp.0000000000001483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
ABSTRACT In the event of a radiological accident involving external exposure of one or more victims and potential high doses, it is essential to know the dose distribution within the body in order to sort the victims according to the severity of the irradiation and then to take them to the most suitable medical facilities. However, there are currently few techniques that can be rapidly deployed on field and capable of characterizing an irradiation. Therefore, a numerical simulation tool has been designed. It can be implemented by a doctor/physicist pairing, projected within a limited time as close as possible to the irradiation accident and emergency response teams. Called SEED (Simulation of External Exposures & Dosimetry), this tool (dedicated to dose reconstruction in case of external exposure) allows a rapid modeling of the irradiation scene and a visual exchange with the victims and witnesses of the event. The user can navigate in three dimensions in the accident scene thanks to a graphical user interface including a "first person" camera. To validate the performance of the SEED tool, two dosimetric benchmarking exercises were performed. The first consisted in comparing the dose value provided by SEED to that given by a reference calculation code: MCNPX. The purpose of the second validation was to perform an experiment irradiating a physical dummy equipped with dosimeters and to reconstruct this irradiation using SEED. These two validation protocols have shown satisfactory results with mean difference less than 2% and 12% for the first and second exercises, respectively. They confirm that this new tool is able to provide useful information to medical teams in charge of dosimetric triage in case of a major external exposure event.
Collapse
|
3
|
A small-scale realistic inter-laboratory accident dosimetry comparison using the TL/OSL from mobile phone components. RADIAT MEAS 2022. [DOI: 10.1016/j.radmeas.2021.106696] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
4
|
Development of hematopoietic syndrome mice model for localized radiation exposure. Sci Rep 2021; 11:89. [PMID: 33420217 PMCID: PMC7794306 DOI: 10.1038/s41598-020-80075-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2020] [Accepted: 12/03/2020] [Indexed: 11/09/2022] Open
Abstract
Current models to study the hematopoietic syndrome largely rely on the uniform whole-body exposures. However, in the radio-nuclear accidents or terrorist events, exposure can be non-uniform. The data available on the non-uniform exposures is limited. Thus, we have developed a mice model for studying the hematopoietic syndrome in the non-uniform or partial body exposure scenarios using the localized cobalt60 gamma radiation exposure. Femur region of Strain 'A' male mice was exposed to doses ranging from 7 to 20 Gy. The 30 day survival assay showed 19 Gy as LD100 and 17 Gy as LD50. We measured an array of cytokines and important stem cell markers such as IFN-γ, IL-3, IL-6, GM-CSF, TNF-α, G-CSF, IL-1α, IL-1β, CD 34 and Sca 1. We found significant changes in IL-6, GM-CSF, TNF-α, G-CSF, and IL-1β levels compared to untreated groups and amplified levels of CD 34 and Sca 1 positive population in the irradiated mice compared to the untreated controls. Overall, we have developed a mouse model of the hematopoietic acute radiation syndrome that might be useful for understanding of the non-uniform body exposure scenarios. This may also be helpful in the screening of drugs intended for individuals suffering from radiation induced hematopoietic syndrome.
Collapse
|
5
|
Physical dosimetry reconstructions of significant radiation exposure at an industrial accelerator facility in Tianjin (China). JOURNAL OF RADIATION RESEARCH 2020; 61:82-89. [PMID: 31821503 PMCID: PMC6976733 DOI: 10.1093/jrr/rrz072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/09/2019] [Revised: 07/26/2019] [Accepted: 10/16/2019] [Indexed: 06/10/2023]
Abstract
The goal of this thesis is to estimate the physical radiation doses for two victims who were accidently exposed to an industrial electron beam at an industrial accelerator facility on 7 July 7 2016 in Tianjin, China. On the basis of the radiation source parameters, irradiation situation and irradiation time, physical dose reconstruction was carried out at the accident site by using a Bottle-Manikin-Absorption (BOMAB) phantom and an Alderson Radiation Therapy (ART) phantom. With thermoluminscent dosimeters (TLDs), skin estimation was conducted for the feet, calves, upper arms, left side of the body and neck, and the mean dose was estimated to be 14.1 ± 5.6 Gy. The foot and leg skin received the highest dose, which was >16.3 Gy. In addition, the mean dose estimated for the eye lens was 0.18 ± 0.07 Gy. The organ effective dose estimated and the total organs effective dose estimated were 0.46-4.94 mSv and 0.21 Sv, respectively. In the course of the accident, the damage caused by the electron radiation field to the exposed person was mainly to the skin, and the contributions to other radiation-sensitive organs were small. The damage to the organs other than the skin was mainly caused by the X-rays generated by the bremsstrahlung of the electron beam from the environment or the human body.
Collapse
|
6
|
Deployment of the DosiKit System Under Operational Conditions: Experience From a French Defense National Nuclear Exercise. HEALTH PHYSICS 2018; 115:185-191. [PMID: 29787445 DOI: 10.1097/hp.0000000000000863] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Estimation of the dose received by accidentally irradiated victims is based on a tripod: clinical, biological, and physical dosimetry. The DosiKit system is an operational and mobile biodosimetry device allowing the measurement of external irradiation directly on the site of a radiological accident. This tool is based on capillary blood sample and hair follicle collection. The aim is to obtain a whole-body and local-surface dose assessment. This paper is about the technical evaluation of the DosiKit; the analytical process and scientific validation are briefly described. The Toulon exercise scenario was based on a major accident involving the reactor of a nuclear attack submarine. The design of the scenario made it impossible for several players (firefighters, medical team) to leave the area for a long time, and they were potentially exposed to high dose rates. The DosiKit system was fully integrated into a deployable radiological emergency laboratory, and the response to operational needs was very satisfactory.
Collapse
|
7
|
Study of thermoluminescence (TL) and optically stimulated luminescence (OSL) from α-keratin protein found in human hairs and nails: potential use in radiation dosimetry. RADIATION AND ENVIRONMENTAL BIOPHYSICS 2016; 55:255-264. [PMID: 26846648 DOI: 10.1007/s00411-016-0634-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/30/2014] [Accepted: 01/16/2016] [Indexed: 06/05/2023]
Abstract
The thermoluminescence (TL) and optically stimulated luminescence (OSL) properties of human nails and hairs containing α-keratin proteins have been investigated. For the present studies, black hairs and finger nails were selectively collected from individuals with ages between 25 and 35 years. The collected hairs/nails were cut to a size of < 1 mm and cleaned with distilled water to remove dirt and other potential physical sources of contamination. All samples were optically beached with 470 nm of LED light at 60 mW/cm(2) intensity and irradiated by a (60)Co γ source. The hair and nail samples showed overlapping multiple TL glow peaks in the temperature range from 70 to 210 ° C. Continuous wave (CW)-OSL measurements of hair samples at a wavelength of 470 nm showed the presence of two distinct OSL components with photoionization cross section (PIC) values of about 1.65 × 10(-18) cm(2) and about 3.48 × 10(-19) cm(2), while measurements of nail samples showed PIC values of about 6.98 × 10(-18) cm(2) and about 8.7 × 10(-19) cm(2), respectively. This difference in PIC values for hair and nail samples from the same individual is attributed to different arrangement of α-keratin protein concentrations in the samples. The OSL sensitivity was found to vary ± 5 times among nail and hair samples from different individuals, with significant fading (60% in 11 h) at room temperature. The remaining signal (after fading) can be useful for dose estimation when a highly sensitive OSL reader is used. In the absorbed dose range of 100 mGy-100 Gy, both the TL and OSL signals of hair and nail samples showed linear dose dependence. The results obtained in the present study suggest that OSL using hair and nail samples may provide a supplementary method of dose estimation in radiological and nuclear emergencies.
Collapse
|
8
|
Abstract
According to the International Atomic Energy Agency (IAEA), a relatively significant number of radiological accidents have occurred in recent years mainly because of the practices referred to as potentially high-risk activities, such as radiotherapy, large irradiators and industrial radiography, especially in gammagraphy assays. In some instances, severe injuries have occurred in exposed persons due to high radiation doses. In industrial radiography, 80 cases involving a total of 120 radiation workers, 110 members of the public including 12 deaths have been recorded up to 2014. Radiological accidents in industrial practices in Brazil have mainly resulted in development of cutaneous radiation syndrome (CRS) in hands and fingers. Brazilian data include 5 serious cases related to industrial gammagraphy, affecting 7 radiation workers and 19 members of the public; however, none of them were fatal. Some methods of reconstructive dosimetry have been used to estimate the radiation dose to assist in prescribing medical treatment. The type and development of cutaneous manifestations in the exposed areas of a person is the first achievable gross dose estimation. This review article presents the state-of-the-art reconstructive dosimetry methods enabling estimation of local radiation doses and provides guidelines for medical handling of the exposed individuals. The review also presents the Chilean and Brazilian radiological accident cases to highlight the importance of reconstructive dosimetry.
Collapse
|
9
|
Review of retrospective dosimetry techniques for external ionising radiation exposures. RADIATION PROTECTION DOSIMETRY 2011; 147:573-92. [PMID: 21183550 DOI: 10.1093/rpd/ncq499] [Citation(s) in RCA: 168] [Impact Index Per Article: 12.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic resonance, thermoluminescence, optically stimulated luminescence, neutron activation, haematology, protein biomarkers and analytical dose reconstruction. Individual characteristics of these techniques, their limitations and potential for further development are reviewed, and their usefulness in specific exposure scenarios is discussed. Whilst no single technique fulfils the criteria of an ideal dosemeter, an integrated approach using multiple techniques tailored to the exposure scenario can cover most requirements.
Collapse
|
10
|
Numerical dosimetric reconstruction of a radiological accident in South America in April 2009. RADIATION PROTECTION DOSIMETRY 2011; 144:540-542. [PMID: 21051432 DOI: 10.1093/rpd/ncq338] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
A severe irradiation accident involving a victim occurred in April 2009 in South America. The victim has found a (192)Ir source fallen from a gammagraphy device and has put it in the left pocket of his pants. Very quickly, an erythema and a blister appeared on the left leg of the victim involving hospitalisation. Following the request of the IAEA assistance, the Ionizing Radiation Dosimetry Laboratory of IRSN was asked to perform a numerical dosimetric reconstruction. A personalised voxel phantom of the victim has been constructed thanks to the Simulation of External Source Accident with Medical images tool developed by the laboratory, and a calculation of the dose with the MCNPX computer code allowed to determine the boundary of the necrotic dose at 25 Gy. On the basis of these calculations, the physicians have performed exeresis of the necrotic region on the left leg on 4 May 2009. Associated with mesenchymal stem cell injection, the leg of the victim was healthy on December 2009.
Collapse
|
11
|
European consensus on the medical management of acute radiation syndrome and analysis of the radiation accidents in Belgium and Senegal. HEALTH PHYSICS 2010; 98:825-832. [PMID: 20445389 DOI: 10.1097/hp.0b013e3181ce64d4] [Citation(s) in RCA: 60] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
A European consensus concerning the medical management of mass radiation exposure was obtained in 2005 during a conference held by the European Group for Blood and Bone Marrow Transplantation, the Institute of Radioprotection and Nuclear Safety, and the University of Ulm. At the conference, a two-step triage strategy to deal with large masses of radiation-exposed patients was designed. The first step of this strategy concerns the first 48 h and involves scoring the patients exclusively on the basis of their clinical symptoms and biological data. This allows the non-irradiated bystanders and outpatient candidates to be identified. The remaining patients are hospitalized and diagnosis is confirmed after the first 48-h period according to the METREPOL (Medical Treatment Protocols for radiation accident victims) scale. This grades the patients according to the severity of their symptoms. It was also agreed that in the case of acute radiation syndrome (ARS), emergency hematopoietic stem cell (HSC) transplantation is not necessary. Instead, cytokines that promote hematological reconstruction should be administered as early as possible for 14-21 d. Crucial tests for determining whether the patient has residual hematopoiesis are physical dose reconstructions combined with daily blood count analyses. It was agreed that HSC transplantation should only be considered if severe aplasia persists after cytokine treatment. Two recent cases of accidental radiation exposure that were managed successfully by following the European consensus with modification are reviewed here. Thus, a European standard for the evaluation and treatment of ARS victims is now available. This standard may be suitable for application around the world.
Collapse
|
12
|
Abstract
In the event of large-scale radiation accidents and considering a growing terrorism concern, non-invasive and sufficiently accurate retrospective dosimetry methods are necessary to carry out a fast population triage in order to determine which radiation-exposed individuals need medical treatment. Retrospective dosimetry using different electronic components such as resistors, capacitors, and integrated circuits present on mobile phone circuit boards have been considered. Their response has been investigated with luminescence techniques (OSL, IRSL, and TL). The majority of these electronic components exhibit radiation-induced luminescence signals, and the OSL technique seems the most promising for these materials. Results concerning three types of components that present the most interesting OSL characteristics (in terms of signal annealing and sensitivity) and that are the most often present on mobile phone circuit boards are presented. Preheating effects on OSL signal, sensitization, and dose-response curves from 0.7 to 27 Gy for resistors and from 0.7 to 160 Gy for capacitors and integrated circuits, dose recovery tests, and signal stability 10 h after irradiation have been studied and interests and limits of their use evaluated.
Collapse
|
13
|
Abstract
In case of acute exposure to ionizing radiation, the dose absorbed by the victims has to be rapidly and accurately assessed in order to choose an appropriate medical treatment. Tooth enamel and bone biopsies measured by EPR spectrometry are often used as dose indicators, due to the good radiation sensitivity and the stability of EPR radiation-sensitive signals. Nevertheless, the invasive sampling of teeth and bones limits the application of this technique to retrospective dosimetry. Therefore, we have investigated an alternative non-invasive methodology. We have surveyed with EPR spectrometry the dosimetric properties of the plastics that can be found in personal effects such as glasses (CR-39, polycarbonate), mobile phones (PMMA, polycarbonate), watches and buttons. Dose response, signal stability and effects of storage conditions were investigated. Significant signal fading limits the use for radiation accident dosimetry. Few plastics present the required characteristics to be used in case of a radiation accident.
Collapse
|
14
|
Abstract
Retrospective dosimetry using glass has been investigated. Radiation-induced signals have been surveyed for a large number of watch glasses and display windows of mobile phones with TL and EPR techniques in order to study the variability of dosimetric properties among the different types of samples. Dose response, signal stability, and effects of storage conditions are presented.
Collapse
|
15
|
A rapid multiparametric method for victim triage in cases of accidental protracted irradiation or delayed analysis. Br J Radiol 2009; 82:764-70. [DOI: 10.1259/bjr/49063618] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
|
16
|
|
17
|
Physical dosimetric reconstruction of a radiological accident due to gammagraphy equipment that occurred in Dakar and Abidjan in summer 2006. RADIAT MEAS 2008. [DOI: 10.1016/j.radmeas.2007.12.051] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|