1
|
Guo HL, Wu WW, Huan Y, Zhang HW. SGRT-based stereotactic body radiotherapy for lung cancer setup accuracy and margin of the PTV. J Appl Clin Med Phys 2024; 25:e14195. [PMID: 37915300 DOI: 10.1002/acm2.14195] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Revised: 09/09/2023] [Accepted: 10/18/2023] [Indexed: 11/03/2023] Open
Abstract
OBJECTIVE Surface-guided radiation therapy (SGRT, AlignRT) was used to analyze motion during stereotactic body radiotherapy (SBRT) in lung cancer patients and to explore the margin of the planning target volume (PTV). METHODS The residual errors of the AlignRT were evaluated based on grayscale cone-beam computed tomography registration results before each treatment. AlignRT log file was used to analyze the correlation between the frequency and longest duration of errors larger than 2 mm and lasting longer than 2 s and maximum error with age and treatment duration. The displacement value at the end of treatment, the average displacement value, and the 95% probability density displacement interval were defined as intrafraction errors, and PTV1, PTV2, PTV3 were calculated by Van Herk formula or Z score analysis. Organ dosimetric differences were compared after the experience-based margin was replaced with PTV3. RESULTS The interfraction residual errors were Vrt0 , 0.06 ± 0.18 cm; Lng0 , -0.03 ± 0.19 cm; Lat0 , 0.02 ± 0.15 cm; Pitch0 , 0.23 ± 0.7°; Roll0 , 0.1 ± 0.69°; Rtn0 , -0.02 ± 0.79°. The frequency, longest duration and maximum error in vertical direction were correlated with treatment duration (r = 0.404, 0.353, 0.283, p < 0.05, respectively). In the longitudinal direction, the frequency was correlated with age and treatment duration (r = 0.376, 0.283, p < 0.05, respectively), maximum error was correlated with age (r = 0.4, P < 0.05). Vertical, longitudinal, lateral margins of PTV1, PTV2, PTV3 were 2 mm, 4 mm, 2 mm; 2 mm, 2 mm, 2 mm, 3 mm, 5 mm, 3 mm, respectively. After replacing the original PTV, mean lung dose (MLD), 2-cm3 chest wall dose (CD), lung V20 decreased by 0.2 Gy, 2.1 Gy, 0.5%, respectively (p < 0.05). CONCLUSION AlignRT can be used for interfraction setup and monitoring intrafraction motion. It is more reasonable to use upper and lower limits of the 95% probability density interval as an intrafraction error.
Collapse
Affiliation(s)
- Hai-Liang Guo
- Department of Oncology, the First Affiliated Hospital of Gannan Medical University, Ganzhou, China
| | - Wei-Wei Wu
- Department of Radiotherapy, the Affiliated Cancer Hospital of Gannan Medical University, GanZhou Cancer Hospital, Ganzhou, China
| | - Yan Huan
- Department of Oncology, People's Hospital of Qianxinan Buyi and Miao Minority Autonomous Prefecture, Qian xinan, China
| | - Huai-Wen Zhang
- Department of Radiotherapy, Jiangxi Cancer Hospital, The Second Affiliated Hospital of Nanchang Medical College, NHC Key Laboratory of Personalized Diagnosis and Treatment of Nasopharyngeal Carcinoma, Nanchang, China
- Department of Oncology, The Third People's Hospital of Jingdezhen, Jingdezhen, China
| |
Collapse
|
2
|
Mohamed Yoosuf AB, Alhadab S, Alshehri S, Alhadab A, Alqathami M. Investigation of Intra-fraction Stability and Inter-fraction Consistency of Active Breathing Coordinator (ABC)-Based Deep Inspiration Breath Holds in Left-Sided Breast Cancer. Cureus 2023; 15:e47047. [PMID: 38021774 PMCID: PMC10646616 DOI: 10.7759/cureus.47047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/15/2023] [Indexed: 12/01/2023] Open
Abstract
Background Deep inspiration breath-hold (DIBH) has been established as a standard technique to reduce cardiac dose. The part of the heart exposed to radiation can be significantly decreased using the DIBH technique during tangential left-sided breast cancer (LSBC) irradiation. Aim The objective of this study was to investigate the intra-fraction breath-hold stability and inter-fraction consistency of patient breath-hold against the threshold as a function of air volumes in the setting of active breathing coordinator (ABC)-based DIBH (ABC-DIBH) treatment to LSBC. Methods A total of 34 patients treated with external beam radiation therapy (EBRT) to the left breast using the ABC-DIBH device were included. The frequency of breath-holds per fraction and the entire course of treatment along with the total treatment time was evaluated for all patients. A prescription dose of either 200 cGy (conventional) or 267 cGy (hypofractionation) was administered during 649 fractions, resulting in a total of 4,601 breath-hold measurements being evaluated. The amplitude of deviation in terms of air volumes between the baseline threshold and the patient-specific measurement (during each breath-hold) per fraction was used to define the DIBH stability. Likewise, the consistency of the breathing amplitudes was used to define the compliance of patient breath-holds throughout the entire treatment period. Positional accuracy was evaluated using orthogonal (portal) images. Results The average number of breath-holds measured over the entire course of treatment for each patient was 144 inspirations (58-351). Similarly, the average number of breath-holds for each fraction during the course of treatment was 11 inspirations (7-21), which included setup imaging and treatment. The total number of breath-holds reduced significantly (p-value < 0.05) with hypofractionation (104 inspirations; range 58-170) as compared to conventional fractionation (145 inspirations; 58-351). The average breath-hold threshold in terms of air volume was 1.41 L (0.6-2.1 L) for all patients. The total treatment time reduced significantly after the third fraction (p-value < 0.05). The average deviation between the measured and baseline threshold breath-holds during the course of treatment was 0.5 L/sec (0.12-1.32 L/sec). The consistency of the breathing amplitudes were maintained within ±0.05 L during the entire treatment for all patients. The average translational shifts measured during setup were 0.28 cm ± 0.3 cm, 0.38 cm ± 0.4 cm, and 0.21 cm ± 0.3 cm in the lateral, longitudinal, and vertical directions, respectively. Conclusion The study has demonstrated the variations in intra-fraction breath-hold stability and inter-fraction breath-hold consistency in terms of air volumes for patients who were treated for LSBC. The frequency of breath-holds was observed to be higher with increased total treatment time for the first few fractions and reduced over the course of treatment.
Collapse
Affiliation(s)
- Ahamed Badusha Mohamed Yoosuf
- Department of Oncology, King Abdulaziz Medical City/Ministry of National Guard Health Affairs, Riyadh, SAU
- Clinical Research, King Abdullah International Medical Research Center, Riyadh, SAU
| | - Saad Alhadab
- Medicine, King Saud Bin Abdulaziz University for Health Sciences College of Medicine, Riyadh, SAU
| | - Salem Alshehri
- Department of Oncology, King Abdulaziz Medical City/Ministry of National Guard Health Affairs, Riyadh, SAU
- Clinical Research, King Abdullah International Medical Research Center, Riyadh, SAU
| | - Abdulrahman Alhadab
- Department of Oncology, King Abdulaziz Medical City/Ministry of National Guard Health Affairs, Riyadh, SAU
- Clinical Research, King Abdullah International Medical Research Center, Riyadh, SAU
| | - Mamdouh Alqathami
- Department of Oncology, King Abdulaziz Medical City/Ministry of National Guard Health Affairs, Riyadh, SAU
- Clinical Research, King Abdullah International Medical Research Center, Riyadh, SAU
- Radiological Sciences, King Saud Bin Abdulaziz University, Riyadh, SAU
| |
Collapse
|
3
|
Cheng JC, Buduhan G, Venkataraman S, Tan L, Sasaki D, Bashir B, Ahmed N, Kidane B, Sivananthan G, Koul R, Leylek A, Butler J, McCurdy B, Wong R, Kim JO. Endobronchially Implanted Real-Time Electromagnetic Transponder Beacon-Guided, Respiratory-Gated SABR for Moving Lung Tumors: A Prospective Phase 1/2 Cohort Study. Adv Radiat Oncol 2023; 8:101243. [PMID: 37408673 PMCID: PMC10318214 DOI: 10.1016/j.adro.2023.101243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2023] [Accepted: 04/03/2023] [Indexed: 07/07/2023] Open
Abstract
Purpose Endobronchial electromagnetic transponder beacons (EMT) provide real-time, precise positional data of moving lung tumors. We report results of a phase 1/2, prospective, single-arm cohort study evaluating the treatment planning effects of EMT-guided SABR for moving lung tumors. Methods and Materials Eligible patients were adults, Eastern Cooperative Oncology Group 0 to 2, with T1-T2N0 non-small cell lung cancer or pulmonary metastasis ≤4 cm with motion amplitude ≥5 mm. Three EMTs were endobronchially implanted using navigational bronchoscopy. Four-dimensional free-breathing computed tomography simulation scans were obtained, and end-exhalation phases were used to define the gating window internal target volume. A 3-mm expansion of gating window internal target volume defined the planning target volume (PTV). EMT-guided, respiratory-gated (RG) SABR was delivered (54 Gy/3 fractions or 48 Gy/4 fractions) using volumetric modulated arc therapy. For each RG-SABR plan, a 10-phase image-guided SABR plan was generated for dosimetric comparison. PTV/organ-at-risk (OAR) metrics were tabulated and analyzed using the Wilcoxon signed-rank pair test. Treatment outcomes were evaluated using RECIST (Response Evaluation Criteria in Solid Tumours; version 1.1). Results Of 41 patients screened, 17 were enrolled and 2 withdrew from the study. Median age was 73 years, with 7 women. Sixty percent had T1/T2 non-small cell lung cancer and 40% had M1 disease. Median tumor diameter was 1.9 cm with 73% of targets located peripherally. Mean respiratory tumor motion was 1.25 cm (range, 0.53-4.04 cm). Thirteen tumors were treated with EMT-guided SABR and 47% of patients received 48 Gy in 4 fractions while 53% received 54 Gy in 3 fractions. RG-SABR yielded an average PTV reduction of 46.9% (P < .005). Lung V5, V10, V20, and mean lung dose had mean relative reductions of 11.3%, 20.3%, 31.1%, and 20.3%, respectively (P < .005). Dose to OARs was significantly reduced (P < .05) except for spinal cord. At 6 months, mean radiographic tumor volume reduction was 53.5% (P < .005). Conclusions EMT-guided RG-SABR significantly reduced PTVs of moving lung tumors compared with image-guided SABR. EMT-guided RG-SABR should be considered for tumors with large respiratory motion amplitudes or those located in close proximity to OARs.
Collapse
Affiliation(s)
- Jui Chih Cheng
- Radiation Oncology, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Gordon Buduhan
- Thoracic Surgery, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | | | - Lawrence Tan
- Thoracic Surgery, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - David Sasaki
- Medical Physics, CancerCare Manitoba, Winnipeg, Manitoba, Canada
| | - Bashir Bashir
- Radiation Oncology, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Naseer Ahmed
- Radiation Oncology, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Biniam Kidane
- Thoracic Surgery, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Gokulan Sivananthan
- Radiation Oncology, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Rashmi Koul
- Radiation Oncology, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Ahmet Leylek
- Radiation Oncology, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - James Butler
- Radiation Oncology, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Boyd McCurdy
- Medical Physics, CancerCare Manitoba, Winnipeg, Manitoba, Canada
| | - Ralph Wong
- Medical Oncology, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
| | - Julian O. Kim
- Radiation Oncology, Max Rady Faculty of Health Sciences, University of Manitoba, Winnipeg, Manitoba, Canada
- CancerCare Manitoba Research Institute, Winnipeg, Manitoba, Canada
| |
Collapse
|
4
|
Nguyen D, Reinoso R, Farah J, Yossi S, Lorchel F, Passerat V, Louet E, Pouchard I, Khodri M, Barbet N. Reproducibility of surface-based deep inspiration breath-hold technique for lung stereotactic body radiotherapy on a closed-bore gantry linac. Phys Imaging Radiat Oncol 2023; 26:100448. [PMID: 37252251 PMCID: PMC10213090 DOI: 10.1016/j.phro.2023.100448] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Revised: 05/05/2023] [Accepted: 05/09/2023] [Indexed: 05/31/2023] Open
Abstract
Background and purpose Tumor motion and delivery efficiency are two main challenges of lung stereotactic body radiotherapy (SBRT). The present work implemented the deep inspiration breath hold technique (DIBH) with surface guided radiation therapy (SGRT) on closed-bore linacs and investigated the correlation between SGRT data and internal target position. Materials and methods Thirteen lung SBRT patients treated in DIBH using a closed-bore gantry linac and a ring-mounted SGRT system were retrospectively analysed. Visual coaching was used to achieve DIBH with a ± 1 mm threshold window in the anterior-posterior direction. Three kV-CBCTs were added to the treatment workflow and examined offline to verify intra-fraction tumor position. Surface-based DIBH was analysed using SGRT treatment reports and an in-house python script. Data from 73 treatment sessions and 175 kV-CBCTs were studied. Correlations between target and surface positions were studied with Linear Mixed Models. Results Median intra-fraction tumor motion was 0.8 mm (range: 0.7-1.3 mm) in the anterior-posterior direction, 1.2 mm (range: 1-1.7 mm) in the superior-inferior direction, and 1 mm (range: 0.7-1.1 mm) in the left-right direction, with rotations of <1° (range: 0.6°-1.1°) degree in all three directions. Planned target volumes and healthy lung volumes receiving 12.5 Gy and 13.5 Gy were reduced on average by 67% and 54%, respectively. Conclusions Lung SBRT in DIBH with the ring-mounted SGRT system proved reproducible. The surface monitoring provided by SGRT was found to be a reliable surrogate for internal target motion. Moreover, the implementation of DIBH technique helped reduce target volumes and lung doses.
Collapse
Affiliation(s)
- Daniel Nguyen
- ORLAM’s Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France
| | - Rebeca Reinoso
- ORLAM’s Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France
| | - Jad Farah
- Vision RT Ltd., Dove House, Arcadia Avenue, London N3 2JU, United Kingdom
| | - Sena Yossi
- ORLAM’s Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France
| | - Fabrice Lorchel
- ORLAM’s Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France
| | - Victor Passerat
- ORLAM’s Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France
| | - Estelle Louet
- ORLAM’s Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France
| | - Isabelle Pouchard
- ORLAM’s Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France
| | - Mustapha Khodri
- ORLAM’s Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France
| | - Nicolas Barbet
- ORLAM’s Group, Department of Radiation Oncology, Mâcon, Villeurbanne, Lyon, France
| |
Collapse
|
5
|
Chen H, Piao Y, Yang D, Kuang P, Li Z, Liao G, Zhong H. The effect of respiratory capacity for dose sparing in left-sided breast cancer irradiation with active breathing coordinator technique. Front Oncol 2022; 12:989220. [PMID: 36263201 PMCID: PMC9576200 DOI: 10.3389/fonc.2022.989220] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Accepted: 09/14/2022] [Indexed: 11/13/2022] Open
Abstract
Background and aimA subsequent cardiac toxicity is deemed to be dose-dependent for left-sided breast cancer irradiation. This study aims to demonstrate the effect of respiratory capacity for dose sparing when the deep inspiration breath hold with Active Breathing Coordinator technique (ABC-DIBH) is used in left-sided breast cancer irradiation.Methods74 left-sided breast cancer patients, who received whole breast or post-mastectomy chest wall radiotherapy with ABC-DIBH between 2020 and 2021 in our center, were retrospectively reviewed in this study. CT scans of free breath (FB) and ABC-DIBH were done for each patient, and two treatment plans with a prescription dose of 5000 cGy/25 Fr were designed separately. The dose to heart, left anterior descending artery (LAD) and lungs was compared between FB and ABC-DIBH. The correlation between individual parameters (dose to organs at risk (OARs) and minimum heart distance (MHD)) was analyzed, and the effect of respiratory capacity for dose sparing was assessed.ResultsThe plans with ABC-DIBH achieved lower Dmean for heart (34.80%, P < 0.01) and LAD (29.33%, P < 0.01) than those with FB. Regression analysis revealed that both Dmean and D2 of heart were negatively correlated with MHD in the plans with FB and ABC-DIBH, which decreased with the increase in MHD by 37.8 cGy and 309.9 cGy per 1mm, respectively. Besides, a lower Dmean of heart was related to a larger volume of ipsilateral lung in plans with FB. With the increase in volume of ipsilateral lung, the linear correlation was getting weaker and weaker until the volume of ipsilateral lung reached 1700 cc. Meanwhile, a negative linear correlation between Dmean of LAD and MHD in plans with FB and ABC-DIBH was observed, whose slope was 162.5 and 135.9 cGy/mm, respectively. Furthermore, when the respiratory capacity of ABC-DIBH reached 1L, and the relative ratio (ABC-DIBH/FB) reached 3.6, patients could obtain the benefit of dose sparing. The larger difference in respiratory capacity had no significant effect in the larger difference of MHD, Dmean of heart and Dmean of LAD between FB and ABC-DIBH.ConclusionThis study demonstrates the sufficiently good effect of ABC-DIBH when utilizing for cardiac sparing. It also reveals the correlations among individual parameters and the effect of respiratory capacity for dose sparing. This helps take optimal advantage of the ABC-DIBH technique and predict clinical benefits.
Collapse
Affiliation(s)
| | - Ying Piao
- *Correspondence: Heli Zhong, ; Ying Piao,
| | | | | | | | | | - Heli Zhong
- *Correspondence: Heli Zhong, ; Ying Piao,
| |
Collapse
|
6
|
Lawler G. A review of surface guidance in extracranial stereotactic body radiotherapy (SBRT/SABR) for set-up and intra-fraction motion management. Tech Innov Patient Support Radiat Oncol 2022; 21:23-26. [PMID: 35079644 PMCID: PMC8777133 DOI: 10.1016/j.tipsro.2022.01.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2021] [Revised: 12/20/2021] [Accepted: 01/06/2022] [Indexed: 12/25/2022] Open
Abstract
Introduction Surface guidance (SG) radiotherapy (RT) is now used by many radiotherapy departments globally and has expanded in popularity over the last number of years. A number of commercial systems are available. SG has routinely been used and is well established for cranial stereotactic radiosurgery (SRS) patient set ups and intra-fraction motion monitoring. However, data is limited in relation to its clinical use for extracranial stereotactic body radiotherapy (SBRT), particularly for targets which are impacted by respiratory motion such as the lung and liver. Objective & Information Source A review of available literature was carried out on 24th October 2021 to assess the clinical feasibility and use of SG in SBRT via PubMed. Methods Eligibility Criteria The search criteria involved identifying articles where SG is used in extracranial SBRT. Risk of Bias To eliminate the risk of bias, any particular commercial system was not the focus of the review and not included in the search criteria. Numerous clinical terms for similar things were used to reduce the risk of missing papers e.g. SBRT and SABR. Search Criteria The PRISMA checklist was used. Searching for “surface guidance and radiotherapy” yielded 3271 results, where as “SGRT” alone returned 72 results, when the search term was narrowed down using different iterations of SG and SBRT, only 6 results were available. Of these, 4 had reviewed clinical data in relation to SG and SBRT for patient set up and intra-fraction motion monitoring. Results The 4 studies indicate positive results for using SG with sufficient image guidance (IG) for both patient set up and intra-fraction monitoring during SBRT. This was observed both in free breathing and in patients with respiratory motion management being employed such as deep inspiration breath-hold (DIBH) techniques. All used multiple IGRT solutions to verify localisation pre-treatment in conjunction with SG. Limitations The number of studies available which report using SG in SBRT is extremely limited. All centres had also installed SG systems therefore this could result in an unconditional bias in using the system positively. Conclusion SG can be used for SBRT set-ups and intra-fraction motion monitoring once sufficient IG is used to verify target localisation for treatment.
Collapse
|
7
|
Lee S, Lee D, Verma V, Waters D, Oh S, Colonias A, Wegner R, Pavord D, Coopey B, Fuhrer R, Sohn JW. Dosimetric benefits of dynamic conformal arc therapy-combined with active breath-hold in lung stereotactic body radiotherapy. Med Dosim 2021; 47:54-60. [PMID: 34583857 DOI: 10.1016/j.meddos.2021.08.004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2021] [Revised: 07/22/2021] [Accepted: 08/16/2021] [Indexed: 11/30/2022]
Abstract
To test the hypothesis that dynamic conformal arc therapy (DCAT) in Monaco, compared with volumetric modulated arc therapy (VMAT), maintains plan quality with higher delivery efficiency for lung stereotactic body radiotherapy (SBRT) and to investigate dosimetric benefits of DCAT with active breath-hold (DCAT+ABH), compared with free-breathing (DCAT+FB) for varying tumor sizes and motions. Fifty DCAT plans were used for lung SBRT. Randomly selected 17 DCAT plans were evaluated with respect to the retrospectively generated volumetric modulated arc therapy (VMAT) plans. The maximum dose at 2 cm from planning target volume (PTV) in any direction (D2cm/Rx), the ratio of 50% prescription isodose volume to the PTV (R50%), conformity index (CI), the lung volume receiving ≥20 Gy (V20), and monitor unit (MU) were evaluated. A t-test was used to evaluate the difference of plan quality between DCAT and VMAT. Internal target volume (ITV)/integrated-gross target volume (GTV) attributed by intra-fraction motion and lung V20 were stratified for DCAT+ABH and DCAT+FB across varying GTVs. DCAT maintained plan quality (p = 0.154 for D2cm/Rx, p = 0.089 for R50%, p = 0.064 for CI, and p = 0.780 for lung V20) while reducing MUs up to 30% (p <0.001) from 2748 MU (VMAT) to 1868 MU (DCAT). DCAT+ABH, compared to DCAT+FB, reduced tumor motion, resulting in 19% volume reduction of PTV and 60% reduction in lung V20, on average. The difference in lung V20 between DCAT+ABH and DCAT+FB increased as the target size increased. The DCAT is a favorable approach compared with VMAT. These results support the utility of DCAT as a routine planning platform for lung SBRT, especially when utilized with respiratory motion management using the ABH.
Collapse
Affiliation(s)
- Soyoung Lee
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA.
| | - Danny Lee
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA
| | - Vivek Verma
- Department of Radiation Oncology, MD Anderson Cancer Center, Houston, TX 77030 USA
| | - Danielle Waters
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA
| | - Seungjong Oh
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA
| | - Athanasios Colonias
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA
| | - Rodney Wegner
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA
| | - Daniel Pavord
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA
| | - Bryan Coopey
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA
| | - Russell Fuhrer
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA
| | - Jason W Sohn
- Division of Radiation Oncology, Allegheny Health Network Cancer Institution, 320 E North Ave, Ground Floor NW wing, Pittsburgh, PA 15212 USA
| |
Collapse
|
8
|
Naumann P, Batista V, Farnia B, Fischer J, Liermann J, Tonndorf-Martini E, Rhein B, Debus J. Feasibility of Optical Surface-Guidance for Position Verification and Monitoring of Stereotactic Body Radiotherapy in Deep-Inspiration Breath-Hold. Front Oncol 2020; 10:573279. [PMID: 33102232 PMCID: PMC7546313 DOI: 10.3389/fonc.2020.573279] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Accepted: 09/08/2020] [Indexed: 12/25/2022] Open
Abstract
Background Reductions in tumor movement allow for more precise and accurate radiotherapy with decreased dose delivery to adjacent normal tissue that is crucial in stereotactic body radiotherapy (SBRT). Deep inspiration breath-hold (DIBH) is an established approach to mitigate respiratory motion during radiotherapy. We assessed the feasibility of combining modern optical surface-guided radiotherapy (SGRT) and image-guided radiotherapy (IGRT) to ensure and monitor reproducibility of DIBH and to ensure accurate tumor localization for SBRT as an imaging-guided precision medicine. Methods We defined a new workflow for delivering SBRT in DIBH for lung and liver tumors incorporating SGRT and IGRT with cone beam computed tomography (CBCT) twice per treatment fraction. Daily position corrections were analyzed and for every patient two points retrospectively characterized: an anatomically stable landmark (predominately Schmorl's nodes or spinal enostosis) and a respiratory-dependent landmark (predominately surgical clips or branching vessel). The spatial distance of these points was compared for each CBCT and used as surrogate for intra- and interfractional variability. Differences between the lung and liver targets were assessed using the Welch t-test. Finally, the planning target volumes were compared to those of free-breathing plans, prepared as a precautionary measure in case of technical or patient-related problems with DIBH. Results Ten patients were treated with SBRT according this workflow (7 liver, 3 lung). Planning target volumes could be reduced significantly from an average of 148 ml in free breathing to 110 ml utilizing DIBH (p < 0.001, paired t-test). After SGRT-based patient set-up, subsequent IGRT in DIBH yielded significantly higher mean corrections for liver targets compared to lung targets (9 mm vs. 5 mm, p = 0.017). Analysis of spatial distance between the fixed and moveable landmarks confirmed higher interfractional variability (interquartile range (IQR) 6.8 mm) than intrafractional variability (IQR 2.8 mm). In contrast, lung target variability was low, indicating a better correlation of patients' surface to lung targets (intrafractional IQR 2.5 mm and interfractional IQR 1.7 mm). Conclusion SBRT in DIBH utilizing SGRT and IGRT is feasible and results in significantly lower irradiated volumes. Nevertheless, IGRT is of paramount importance given that interfractional variability was high, particularly for liver tumors.
Collapse
Affiliation(s)
- Patrick Naumann
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Vania Batista
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Benjamin Farnia
- Department of Radiation Oncology, University of Miami, Miami, FL, United States
| | - Jann Fischer
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Jakob Liermann
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Eric Tonndorf-Martini
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany
| | - Bernhard Rhein
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany
| | - Jürgen Debus
- Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,Heidelberg Institute of Radiation Oncology (HIRO), Heidelberg, Germany.,National Center for Tumor diseases (NCT), Heidelberg, Germany.,Heidelberg Ion-Beam Therapy Center (HIT), Department of Radiation Oncology, Heidelberg University Hospital, Heidelberg, Germany.,German Cancer Consortium (DKTK), Heidelberg, Germany.,Clinical Cooperation Unit Radiation Oncology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
9
|
Tong Y, Gong G, Su M, Yin Y. Comparison of the dose on specific 3DCT images and the accumulated dose for cardiac structures in esophageal tumors radiotherapy: whether specific 3DCT images can be used for dose assessment? Radiat Oncol 2019; 14:242. [PMID: 31881901 PMCID: PMC6935068 DOI: 10.1186/s13014-019-1450-6] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/17/2019] [Accepted: 12/19/2019] [Indexed: 01/23/2023] Open
Abstract
BACKGROUND Cardiac activity could impact the accuracy of dose assessment for the heart, pericardium and left ventricular myocardium (LVM). The purpose of this study was to explore whether it is possible to perform dose assessment by contouring the cardiac structures on specific three-dimensional computed tomography (3DCT) images to reduce the impact of cardiac activity. METHODS Electrocardiograph-gated 4DCT (ECG-gated 4DCT) images of 22 patients in breath-hold were collected. MIM Maestro 6.8.2 (MIM) was used to reconstruct specific 3DCT images to obtain the Maximal intensity projection (MIP) image, Average intensity projection (AIP) image and Minimum intensity projection (Min-IP) image. The heart, pericardium and LVM were contoured in 20 phases of 4DCT images (0, 5%... 95%) and the MIP, AIP and Min-IP images. Then, a radiotherapy plan was designed at the 0% phase of the 4DCT images, and the dose was transplanted to all phases of 4DCT to acquire the dose on all phases, the accumulated dose of all phases was calculated using MIM. The dose on MIP, AIP and Min-IP images were also obtained by deformable registration of the dose. The mean dose (Dmean), V5, V10, V20, V30 and V40 for the heart, pericardium and LVM in MIP, AIP and Min-IP images were compared with the corresponding parameters after dose accumulation. RESULTS The mean values of the difference between the Dmean in the MIP image and the Dmean after accumulation for the heart, pericardium and LVM were all less than 1.50 Gy, and the dose difference for the pericardium and LVM was not statistically significant (p > 0.05). For dose-volume parameters, there was no statistically significant difference between V5, V10, and V20 of the heart and pericardium in MIP, AIP, and Min-IP images and those after accumulation (p > 0.05). For the LVM, only in the MIP image, the differences of V5, V10, V20, V30 and V40 were not significant compared to those after dose accumulation (p > 0.05). CONCLUSIONS There was a smallest difference for the dosimetry parameters of cardiac structures on MIP image compared to corresponding parameters after dose accumulation. Therefore, it is recommended to use the MIP image for the delineation and dose assessment of cardiac structures in clinical practice.
Collapse
Affiliation(s)
- Ying Tong
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
| | - Guanzhong Gong
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China
| | - Ming Su
- School of Nuclear Science and Technology, University of South China, Hengyang, China
| | - Yong Yin
- Shandong Cancer Hospital and Institute, Shandong First Medical University and Shandong Academy of Medical Sciences, Jinan, China.
| |
Collapse
|