Chen DJ, Zhao M, Lu JW, Sun H, Jiang W, Liang J. Dosimetric superiority of deep inspiration breath hold-proton beam therapy for cardiac metastasis. Med Dosim 2025:S0958-3947(25)00015-9. [PMID: 40157883 DOI: 10.1016/j.meddos.2025.02.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2024] [Revised: 02/15/2025] [Accepted: 02/26/2025] [Indexed: 04/01/2025]
Abstract
The purpose of this case report is to compare the dosimetric disparities between photon radiotherapy and intensity-modulated proton therapy (IMPT) with or without deep inspiration breath hold (DIBH) for cardiac tumors. We present a case involving a 66-year-old female with cardiac metastasis from thymic carcinoma. A total dose of 50Gy/50Gy(RBE) in 25 fractions was administered to the cardiac metastases. Two simulation CT scans were obtained during free breath (FB) and DIBH. Dose distribution to target and organs at risk(OARs) was compared between intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and IMPT. All of the 6 plans satisfied treatment planning goals. The coronary artery (CA) Dmean (mean dose) was 28.32 Gy for IMRT-DIBH, 42.66 Gy for IMRT-FB, 26.44 Gy for VMAT-DIBH, 40.85 Gy for VMAT-FB, 27.71 Gy for IMPT-DIBH, and 39.51 Gy for IMPT-FB. The heart V50 (volume receiving ≥50 Gy) was 3.90 Gy for IMRT-DIBH, 6.71 Gy for IMRT-FB, 4.80 Gy for VMAT-DIBH, 6.63 Gy for VMAT-FB, 0.99 Gy for IMPT-DIBH, and 6.67 Gy for IMPT-FB, respectively. DIBH resulted in dose reductions in all OARs, particularly the heart and CA, compared to FB in all 3 planning techniques (IMRT, VMAT, and IMPT). Similarly, compared with IMRT or VMAT, IMPT reduced radiation doses to most OARs, including the heart and CA, in both FB and DIBH. DIBH-IMPT demonstrated superior dose coverage and OARs sparing in this thymic carcinoma patient with cardiac metastasis. Given the anticipated reduction in toxicities, IMPT with DIBH is preferred for cardiac tumors. The potential for broader application of IMPT with DIBH in clinical practice is currently being evaluated, and further studies are needed.
Collapse
Affiliation(s)
- Dong-Jie Chen
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen 518116, China
| | - Man Zhao
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen 518116, China
| | - Jia-Wei Lu
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen 518116, China
| | - Han Sun
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen 518116, China
| | - Wei Jiang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen 518116, China.
| | - Jun Liang
- National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital & Shenzhen Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Shenzhen 518116, China
| |
Collapse
|
2
|
Kuijer KM, Bouwmans R, Bosma LS, Mook S, Meijer GJ. A simplified online adaptive workflow for long-course magnetic resonance-guided radiotherapy in esophageal cancer. Phys Imaging Radiat Oncol 2025; 33:100717. [PMID: 39981524 PMCID: PMC11840183 DOI: 10.1016/j.phro.2025.100717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2024] [Revised: 01/22/2025] [Accepted: 01/27/2025] [Indexed: 02/22/2025] Open
Abstract
Background and Purpose Online adaptive magnetic resonance-guided radiotherapy (MRgRT) enables high-precision radiotherapy for esophageal cancer patients but is less feasible due to long on-table times in combination with long-course treatment. In this study, we conducted an in-silico assessment of a simplified online adaptive workflow, Adapt-To-Shape-lite (ATS-lite), in which deformable propagated contours are not modified, and assessed its feasibility. Materials and Methods The ATS-lite workflow was simulated for all fractions of nine esophageal cancer patients who had previously received full online adaptive MRgRT with manual contour corrections if needed. The deformable propagated contours were not adjusted. A dose of 41.4 Gy in 23 fractions was prescribed. Intra- and interfraction dose accumulation were performed to evaluate target coverage per fraction and across the entire treatment. For individual fractions, coverage of the manually corrected clinical target volume (CTV) was considered adequate if V95% > 98 % and V90% > 99.5 %. Feasibility was assessed by recording treatment times in the first patients treated with ATS-lite. Results The ATS-lite workflow provided adequate target coverage over the entire treatment for all patients, with sufficient coverage in 90% of the 177 fractions analyzed. Closer inspection revealed that inadequate target coverage in individual fractions was primarily attributed to enlargement of the manually corrected CTV, rather than poor contour propagation in the ATS-lite workflow. In seven patients, the ATS-lite workflow achieved a median time per fraction of 23 min. Conclusions The ATS-lite workflow provides adequate target coverage and is feasible for online adaptive MRgRT in long-course esophageal cancer treatments.
Collapse
Affiliation(s)
- Koen M. Kuijer
- Department of Radiotherapy, University Medical Centre Utrecht, Utrecht, the Netherlands
| | - Roel Bouwmans
- Department of Radiotherapy, University Medical Centre Utrecht, Utrecht, the Netherlands
| | - Lando S. Bosma
- Department of Radiotherapy, University Medical Centre Utrecht, Utrecht, the Netherlands
| | | | | |
Collapse
|
3
|
Herbst P, Draguet C, Barragán-Montero AM, Villarroel EB, Vera MC, Populaire P, Haustermans K, Sterpin E. Potential of automated online adaptive proton therapy to reduce margins for oesophageal cancer. Phys Imaging Radiat Oncol 2025; 33:100712. [PMID: 40123774 PMCID: PMC11926429 DOI: 10.1016/j.phro.2025.100712] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2024] [Revised: 12/04/2024] [Accepted: 01/23/2025] [Indexed: 03/25/2025] Open
Abstract
Background and purpose Proton therapy for oesophageal cancer is administered over multiple fractions, based on a single pre-treatment image. However, anatomical changes can lead to the deterioration of the treatment plan, necessitating manual replanning. To keep this within limits, increased residual margins are employed. This study aimed to evaluate the proposed automated Online Adaptive Proton Therapy (OAPT) strategies on their capability to reduce the need for manual replanning, while also exploring the possibility of margin reduction. Materials and methods Two automated OAPT methods were examined: Automated Dose Restoration (ADR) and Automated Full Adaptation (AFA). ADR makes use of dose restoration, restoring the original dose map based on the patient's altered anatomy. AFA adapts the contours used for plan optimization by applying a deformation field, not only correcting for density changes, but also for the relative location of organs. A comparative analysis of OAPT strategies, evaluatingD 98% tumour coverage on 17 patients, was conducted. Results The nominal results of non-adapted plans with 7 mm residual margins required manual replanning for 18% of the patients. ADR reduced this to 6%, while AFA eliminated the need for manual replanning. With 2 mm margins, 47% of cases required manual replanning. ADR reduced this to 18%, and AFA further reduced it to 11%. Conclusions The proposed OAPT strategies offered a marked improvement compared to a non-adaptive approach. ADR and AFA significantly reduced the necessity for manual replanning and facilitated the reduction of residual margins, enhancing dose conformity and reducing treatment toxicity.
Collapse
Affiliation(s)
- Pascal Herbst
- KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
- UCLouvain, Institut de Recherche Expérimentale et Clinique, Center of Molecular Imaging, Radiotherapy and Oncology (MIRO), Brussels, Belgium
- RaySearch Laboratories AB, Stockholm, Sweden
| | - Camille Draguet
- KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
- UCLouvain, Institut de Recherche Expérimentale et Clinique, Center of Molecular Imaging, Radiotherapy and Oncology (MIRO), Brussels, Belgium
| | - Ana M. Barragán-Montero
- UCLouvain, Institut de Recherche Expérimentale et Clinique, Center of Molecular Imaging, Radiotherapy and Oncology (MIRO), Brussels, Belgium
| | - Elena Borderías Villarroel
- UCLouvain, Institut de Recherche Expérimentale et Clinique, Center of Molecular Imaging, Radiotherapy and Oncology (MIRO), Brussels, Belgium
| | - Macarena Chocan Vera
- UCLouvain, Institut de Recherche Expérimentale et Clinique, Center of Molecular Imaging, Radiotherapy and Oncology (MIRO), Brussels, Belgium
| | - Pieter Populaire
- KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
- University Hospital Leuven, Department of Radiation Oncology, Leuven, Belgium
| | - Karin Haustermans
- KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
- University Hospital Leuven, Department of Radiation Oncology, Leuven, Belgium
| | - Edmond Sterpin
- KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium
- UCLouvain, Institut de Recherche Expérimentale et Clinique, Center of Molecular Imaging, Radiotherapy and Oncology (MIRO), Brussels, Belgium
| |
Collapse
|
4
|
Bachmann N, Schmidhalter D, Corminboeuf F, Berger MD, Borbély Y, Ermiş E, Stutz E, Shrestha BK, Aebersold DM, Manser P, Hemmatazad H. Cone Beam Computed Tomography-Based Online Adaptive Radiation Therapy of Esophageal Cancer: First Clinical Experience and Dosimetric Benefits. Adv Radiat Oncol 2025; 10:101656. [PMID: 39628955 PMCID: PMC11612653 DOI: 10.1016/j.adro.2024.101656] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2024] [Accepted: 10/07/2024] [Indexed: 12/06/2024] Open
Abstract
Purpose Radiation therapy (RT) plays a key role in the management of esophageal cancer (EC). However, toxicities caused by proximity of organs at risk (OAR) and daily target coverage caused by interfractional anatomic changes are of concern. Daily online adaptive RT (oART) addresses these concerns and has the potential to increase OAR sparing and improve target coverage. We present the first clinical experience and dosimetric investigations of cone beam CT-based oART in EC using the ETHOS platform. Methods and Materials Treatment fractions of the first 10 EC patients undergoing cone beam CT-based oART at our institution were retrospectively analyzed. The prescription dose was 50.4 Gy in 28 fractions. The same clinical target volume (CTV) and planning target volume (PTV) margins as for nonadaptive treatments were used. For all sessions, the timestamp of each oART workflow step, PTV size, target volume doses, mean heart dose, and lung V20Gy of both the scheduled and the adapted treatment plan were analyzed. Results Following automatic propagation, the CTV was adapted by the physician in 164 (59%) fractions. The adapted treatment plan was selected in 276 (99%) sessions. The median time needed for an oART session was 28 minutes (range, 14.8-43.3). Compared to the scheduled plans, a significant relative reduction of 9.5% in mean heart dose (absolute, 1.6 Gy; P = .006) and 16.9% reduction in mean lung V20Gy (absolute, 2.3%; P < .001) was achieved with the adapted treatment plans. Simultaneously, we observed a significant relative improvement in D99%PTV and D99%CTV by 15.3% (P < .001) and 5.0% (P = .008), respectively, along with a significant increase in D95%PTV by 5.1% (P = .003). Conclusions Although being resource-intensive, oART for EC is feasible in a reasonable timeframe and results in increased OAR sparing and improved target coverage, even without a reduction of margins. Further studies are planned to evaluate the potential clinical benefits.
Collapse
Affiliation(s)
- Nicolas Bachmann
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Daniel Schmidhalter
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Frédéric Corminboeuf
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Martin D. Berger
- Department of Medical Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Yves Borbély
- Department of Visceral Surgery and Medicine, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Ekin Ermiş
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Emanuel Stutz
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Binaya K. Shrestha
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Daniel M. Aebersold
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Peter Manser
- Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| | - Hossein Hemmatazad
- Department of Radiation Oncology, Inselspital, Bern University Hospital, University of Bern Switzerland, Bern, Switzerland
| |
Collapse
|
5
|
Bachmann N, Schmidhalter D, Corminboeuf F, Ermis E, Aebersold DM, Manser P, Hemmatazad H. Achieving a Pathologic Complete Response for Locally Advanced Esophageal Adenocarcinoma Using Cone-Beam Computed Tomography-Based Online Adaptive Radiotherapy. Cureus 2024; 16:e68753. [PMID: 39371804 PMCID: PMC11456338 DOI: 10.7759/cureus.68753] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 09/04/2024] [Indexed: 10/08/2024] Open
Abstract
Neo-adjuvant chemoradiotherapy (CRT) and perioperative chemotherapy are different strategies for treating non-metastatic esophageal cancer (EC). The advantages of neo-adjuvant therapies are primarily seen in patients who achieve a pathologic complete response (pCR) and therefore show higher survival rates and better prognosis. In general, less than one-third of patients with EC experience pCR after neo-adjuvant therapies; however, patients with esophageal adenocarcinoma (AC) demonstrate lower rates of pCR compared to those with esophageal squamous cell carcinoma (SCC), respectively. Herein, we describe two cases of locally advanced esophageal AC treated with cone-beam computed tomography (CBCT)-based online adaptive radiotherapy (ART) on the ETHOS platform. Both patients received CRT with 50.4 Gy in 28 fractions, combined with weekly carboplatin and paclitaxel. For each fraction, we evaluated scheduled and adapted plans using dose-volume histogram (DVH) data, and patients were treated with the superior plan. We prioritized ensuring optimal coverage of the planning target volume (PTV) over limiting the dose to organs at risk (OARs) when selecting the superior treatment plan. In this instance, we present the translation of superior dosimetric data into clinical benefits, as evidenced by an excellent pathologic response.
Collapse
Affiliation(s)
- Nicolas Bachmann
- Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, CHE
| | - Daniel Schmidhalter
- Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, CHE
| | - Frédéric Corminboeuf
- Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, CHE
| | - Ekin Ermis
- Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, CHE
| | - Daniel M Aebersold
- Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, CHE
| | - Peter Manser
- Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, CHE
| | - Hossein Hemmatazad
- Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, CHE
| |
Collapse
|
6
|
Boekhoff MR, Lagendijk JJ, L.H.M.W. van Lier A, Mook S, Meijer GJ. Intrafraction motion analysis in online adaptive radiotherapy for esophageal cancer. Phys Imaging Radiat Oncol 2023; 26:100432. [PMID: 37020582 PMCID: PMC10068261 DOI: 10.1016/j.phro.2023.100432] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 03/14/2023] [Accepted: 03/15/2023] [Indexed: 03/22/2023] Open
Abstract
Intrafraction motion during magnetic resonance (MR)-guided dose delivery of esophageal cancer tumors was retrospectively analyzed. Deformable image registration of cine-MR series resulted in gross tumor volume motion profiles in all directions, which were subsequently filtered to isolate respiratory and drift motion. A large variability in intrafraction motion patterns was observed between patients. Median 95% peak-to-peak motion was 7.7 (3.7 - 18.3) mm, 2.1 (0.7 - 5.7) mm and 2.4 (0.5 - 5.6) mm in cranio-caudal, left-right and anterior-posterior directions, relatively. Furthermore, intrafraction drift was generally modest (<5mm). A patient specific approach could lead to very small margins (<3mm) for most patients.
Collapse
|
7
|
Boekhoff M, Bouwmans R, Doornaert P, Intven M, Lagendijk J, van Lier A, Rasing M, van de Ven S, Meijer G, Mook S. Clinical implementation and feasibility of long-course fractionated MR-guided chemoradiotherapy for patients with esophageal cancer: an R-IDEAL stage 1b/2a evaluation of technical innovation. Clin Transl Radiat Oncol 2022; 34:82-89. [PMID: 35372703 PMCID: PMC8971577 DOI: 10.1016/j.ctro.2022.03.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 03/15/2022] [Indexed: 11/05/2022] Open
Abstract
Online MR-guided long-course fractionated chemoradiotherapy for patients with esophageal cancer was feasible in 7 out of 9 patients. Median treatment time was 53 min per fraction. MRgRT resulted in a reduction in mean heart dose (12%) and mean lung dose (26%) compared to CBCT-guided radiotherapy. Limited intrafraction motion was observed during dose delivery.
Purpose This R-Ideal stage 1b/2a study describes the workflow and feasibility of long-course fractionated online adaptive MR-guided chemoradiotherapy with reduced CTV-to-PTV margins on the 1.5T MR-Linac for patients with esophageal cancer. Methods Patients with esophageal cancer scheduled to undergo chemoradiation were treated on a 1.5T MR-Linac. Daily MR-images were acquired for online contour adaptation and replanning. Contours were manually adapted to match the daily anatomy and an isotropic CTV-to-PTV margin of 6 mm was applied. Time was recorded for all individual steps in the workflow. Feasibility and patient tolerability were defined as on-table time of ≤60 min and completion of >95% of the fractions on the MR-Linac, respectively. Positioning verification and post-treatment MRIs were retrospectively analyzed and dosimetric parameters were compared to standard non-adaptive conventional treatment plans. Results Nine patients with esophageal cancer were treated with chemoradiation; eight patients received 41.4 Gy in 23 fractions and one received 50.4 Gy in 28 fractions. Four patients received all planned fractions on the MR-Linac, whereas for two patients >5% of fractions were rescheduled to a conventional linac for reasons of discomfort. A total of 183 (86%) of 212 scheduled fractions were successfully delivered on the MR-Linac. Three fractions ended prematurely due to technical issues and 26 fractions were rescheduled on a conventional linac due to MR-Linac downtime (n = 10), logistical reasons (n = 3) or discomfort (n = 13). The median time per fraction was 53 min (IQR = 3 min). Daily adapted MR-Linac plans had similar target coverage, whereas dose to the organs-at-risk was significantly reduced compared to conventional treatment (26% and 12% reduction in mean lung and heart dose, respectively). Conclusion Daily online adaptive fractionated chemoradiotherapy with reduced PTV margins is moderately feasible for esophageal cancer and results in better sparing of heart and lungs. Future studies should focus on further optimization and acceleration of the current workflow.
Collapse
|