den Toom IJ, Mahieu R, van Rooij R, van Es RJJ, Hobbelink MGG, Krijger GC, Tijink BM, de Keizer B, de Bree R. Sentinel lymph node detection in oral cancer: a within-patient comparison between [
99mTc]Tc-tilmanocept and [
99mTc]Tc-nanocolloid.
Eur J Nucl Med Mol Imaging 2020;
48:851-858. [PMID:
32839855 PMCID:
PMC8036184 DOI:
10.1007/s00259-020-04984-8]
[Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Accepted: 07/29/2020] [Indexed: 01/07/2023]
Abstract
Purpose
Sentinel lymph node (SLN) biopsy has proven to reliably stage the clinically negative neck in early-stage oral squamous cell carcinoma (OSCC). [99mTc]Tc-tilmanocept may be of benefit in OSCC with complex lymphatic drainage patterns and close spatial relation to SLNs.
Methods
A prospective within-patient evaluation study was designed to compare [99mTc]Tc-tilmanocept with [99mTc]Tc-nanocolloid for SLN detection. A total of 20 patients with early-stage OSCC were included, who underwent lymphoscintigraphy with both tracers. Both lymphoscintigraphic images of each patient were evaluated for SLN detection and radiotracer distribution at 2–4 h post-injection.
Results
The injection site’s remaining radioactivity was significantly lower for [99mTc]Tc-tilmanocept (29.9%), compared with [99mTc]Tc-nanocolloid (60.9%; p < 0.001). Radioactive uptake in SLNs was significantly lower for [99mTc]Tc-tilmanocept (1.95%) compared with [99mTc]Tc-nanocolloid (3.16%; p = 0.010). No significant difference was seen in SLN to injection site ratio in radioactivity between [99mTc]Tc-tilmanocept (0.066) and [99mTc]Tc-nanocolloid (0.054; p = 0.232). A median of 3.0 and 2.5 SLNs were identified with [99mTc]Tc-tilmanocept and [99mTc]Tc-nanocolloid, respectively (p = 0.297). Radioactive uptake in higher echelon nodes was not significantly different between [99mTc]Tc-tilmanocept (0.57%) and [99mTc]Tc-nanocolloid (0.86%) (p = 0.052). A median of 2.0 and 2.5 higher echelon nodes was identified with [99mTc]Tc-tilmanocept and [99mTc]Tc-nanocolloid, respectively (p = 0.083).
Conclusion
[99mTc]Tc-tilmanocept had a higher injection site clearance, but at the same time a lower uptake in the SLN, resulting in an SLN to injection site ratio, which was not significantly different from [99mTc]Tc-nanocolloid. The relatively low-radioactive uptake in SLNs of [99mTc]Tc-tilmanocept may limit intraoperative detection of SLNs, but can be overcome by a higher injection dose.
Electronic supplementary material
The online version of this article (10.1007/s00259-020-04984-8) contains supplementary material, which is available to authorized users.
Collapse