1
|
Rao S, Sharan K, Chandraguthi SG, Dsouza RN, David LR, Ravichandran S, Mustapha MT, Shettigar D, Uzun B, Kadavigere R, Sukumar S, Ozsahin DU. Advanced Computational Methods for Radiation Dose Optimization in CT. Diagnostics (Basel) 2024; 14:921. [PMID: 38732335 PMCID: PMC11083136 DOI: 10.3390/diagnostics14090921] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2024] [Revised: 04/18/2024] [Accepted: 04/23/2024] [Indexed: 05/13/2024] Open
Abstract
BACKGROUND In planning radiotherapy treatments, computed tomography (CT) has become a crucial tool. CT scans involve exposure to ionizing radiation, which can increase the risk of cancer and other adverse health effects in patients. Ionizing radiation doses for medical exposure must be kept "As Low As Reasonably Achievable". Very few articles on guidelines for radiotherapy-computed tomography scans are available. This paper reviews the current literature on radiation dose optimization based on the effective dose and diagnostic reference level (DRL) for head, neck, and pelvic CT procedures used in radiation therapy planning. This paper explores the strategies used to optimize radiation doses, and high-quality images for diagnosis and treatment planning. METHODS A cross-sectional study was conducted on 300 patients with head, neck, and pelvic region cancer in our institution. The DRL, effective dose, volumetric CT dose index (CTDIvol), and dose-length product (DLP) for the present and optimized protocol were calculated. DRLs were proposed for the DLP using the 75th percentile of the distribution. The DLP is a measure of the radiation dose received by a patient during a CT scan and is calculated by multiplying the CT dose index (CTDI) by the scan length. To calculate a DRL from a DLP, a large dataset of DLP values obtained from a specific imaging procedure must be collected and can be used to determine the median or 75th-percentile DLP value for each imaging procedure. RESULTS Significant variations were found in the DLP, CTDIvol, and effective dose when we compared both the standard protocol and the optimized protocol. Also, the optimized protocol was compared with other diagnostic and radiotherapy CT scan studies conducted by other centers. As a result, we found that our institution's DRL was significantly low. The optimized dose protocol showed a reduction in the CTDIvol (70% and 63%), DLP (60% and 61%), and effective dose (67% and 62%) for both head, neck, and pelvic scans. CONCLUSIONS Optimized protocol DRLs were proposed for comparison purposes.
Collapse
Affiliation(s)
- Shreekripa Rao
- Department of Radiotherapy and Oncology, Manipal College of Health Professions, Manipal 576104, India (R.N.D.)
| | - Krishna Sharan
- Department of Radiotherapy and Oncology, Kasturba Medical College and Hospital, Manipal 576104, India; (K.S.); (S.G.C.)
| | | | - Rechal Nisha Dsouza
- Department of Radiotherapy and Oncology, Manipal College of Health Professions, Manipal 576104, India (R.N.D.)
| | - Leena R. David
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, India; (L.R.D.); (S.R.); (D.S.)
- Department of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates
| | - Sneha Ravichandran
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, India; (L.R.D.); (S.R.); (D.S.)
| | - Mubarak Taiwo Mustapha
- Operational Research Centre in Healthcare, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey; (M.T.M.); (B.U.)
- Department of Biomedical Engineering, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey
| | - Dilip Shettigar
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, India; (L.R.D.); (S.R.); (D.S.)
| | - Berna Uzun
- Operational Research Centre in Healthcare, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey; (M.T.M.); (B.U.)
- Department of Mathematics, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey
| | - Rajagopal Kadavigere
- Department of Radiodiagnosis and Imaging, Kasturba Medical College and Hospital, Manipal 576104, India;
| | - Suresh Sukumar
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, India; (L.R.D.); (S.R.); (D.S.)
| | - Dilber Uzun Ozsahin
- Department of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates
- Operational Research Centre in Healthcare, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey; (M.T.M.); (B.U.)
- Research Institute for Medical and Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates
| |
Collapse
|
2
|
Rao S, Sharan K, Sukumar S, Chandraguthi SG, Nisha Dsouza R, David LR, Ravichandran S, Uzun B, Kadavigere R, Uzun Ozsahin D. Systematic Review on Diagnostic Reference Levels for Computed Tomography Examinations in Radiation Therapy Planning. Diagnostics (Basel) 2023; 13:1072. [PMID: 36980380 PMCID: PMC10047370 DOI: 10.3390/diagnostics13061072] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2023] [Revised: 03/02/2023] [Accepted: 03/09/2023] [Indexed: 03/14/2023] Open
Abstract
Background: In August 2017, the European Commission awarded the "European Study on Clinical Diagnostic Reference Levels (DRL) for X-ray Medical Imaging" project to the European Society of Radiology to provide up-to-date Diagnostic Reference Levels based on clinical indications. This work aimed to conduct an extensive literature review by analyzing the most recent studies published and the data provided by the National Competent Authorities to understand the current situation regarding Diagnostic Reference Levels based on clinical indications for Radiation Therapy Computed Tomography. Objective: To review the literature on established DRLs and methodologies for establishing Diagnostic reference levels in radiation therapy planning computed tomography (RTCT). Methods: Eligibility criteria: A cohort study (observational design) reporting DRLs in adult patients undergoing computed tomography (CT) for radiation therapy for the region head and neck or pelvis were included. The comprehensive literature searches for the relevant studies published between 2000 and 2021 were performed using PubMed, Scopus, CINHAL, Web of Science, and ProQuest. Results: Three hundred fifty-six articles were identified through an extensive literature search. Sixty-eight duplicate reports were removed. The title and abstract of 288 studies were assessed and excluded if they did not meet the inclusion criteria. Sixteen of 288 articles were selected for full-text screening (studies conducted between 2000 and 2021). Five articles were included in the review after the full-text screening. Conclusions: A globally approved standard protocol that includes scanning techniques, dose measurement method, and DRL percentile needs to be established to make a valuable and accurate comparison with international DRLs.
Collapse
Affiliation(s)
- Shreekripa Rao
- Department of Radiotherapy and Oncology, Manipal College of Health Professions, Manipal 576104, Karnataka, India
| | - Krishna Sharan
- Department of Radiotherapy and Oncology, Kasturba Medical College and Hospital, Manipal 576104, Karnataka, India
| | - Suresh Sukumar
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, Karnataka, India
| | | | - Rechal Nisha Dsouza
- Department of Radiotherapy and Oncology, Manipal College of Health Professions, Manipal 576104, Karnataka, India
| | - Leena R. David
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, Karnataka, India
- Department of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates
| | - Sneha Ravichandran
- Department of Medical Imaging Technology, Manipal College of Health Professions, Manipal 576104, Karnataka, India
| | - Berna Uzun
- Department of Statistics, Carlos III Madrid University, 28903 Madrid, Spain
- Operational Research Centre in Healthcare, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey
- Department of Mathematics, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey
| | - Rajagopal Kadavigere
- Department of Radiodiagnosis and Imaging, Kasturba Medical College and Hospital, Manipal 576104, Karnataka, India
| | - Dilber Uzun Ozsahin
- Department of Medical Diagnostic Imaging, College of Health Sciences, University of Sharjah, Sharjah 27272, United Arab Emirates
- Operational Research Centre in Healthcare, Near East University, TRNC Mersin 10, Nicosia 99138, Turkey
| |
Collapse
|
3
|
Božanić A, Šegota D, Debeljuh DD, Kolacio MŠ, Radojčić ĐS, Ružić K, Budanec M, Kasabašić M, Hrepić D, Valković Zujić P, Brambilla M, Kalra MK, Jurković S. National reference levels of CT procedures dedicated for treatment planning in radiation oncology. Phys Med 2022; 96:123-129. [PMID: 35278930 DOI: 10.1016/j.ejmp.2022.03.001] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2021] [Revised: 02/16/2022] [Accepted: 03/02/2022] [Indexed: 11/17/2022] Open
Abstract
OBJECTIVE To present results of the first national survey on reference levels of CT imaging performed for the treatment planning purposes in radiation oncology in Croatia. METHODS Data for CT protocols of five anatomical regions including head, head and neck, pelvis, breast, and thorax were collected at eight radiation oncology departments in Croatia. Data included volume CT dose index (CTDIvol), dose-length product (DLP), scan length and set of acquisition and reconstruction parameters. Data on a total of 600 patients were collected. Median values of scan length, DLP and CTDIvol were calculated for each acquisition protocol. Third quartiles of the median CTDIvol and DLP values were proposed as the national radiotherapy planning reference levels (RPRL). RESULTS The largest CoV were assessed for RT Breast (63.8% for CTDIvol), RT Thorax (79.7% for DLP) and RT H&N (21.2% for scan length). RT Head had the lowest CoV for CTDIvol (1,9%) and DLP (17,2%), while RT Breast had the lowest coefficient of variation for scan length (12.8%). Proposed national RPRLs are: for RT Head CTDIvol16cm = 62 mGy and DLP16cm = 1738 mGy.cm; for RT H&N CTDIvol16cm = 35 mGy and DLP16cm = 1444 mGy.cm; for RT Breast CTDIvol32cm = 16 mGy and DLP32cm = 731 mGy.cm; for RT Thorax CTDIvol32cm = 17 mGy and DLP32cm = 865 mGy.cm; for RT Pelvis CTDIvol32cm = 20 mGy and DLP32cm = 1133 mGy.cm. CONCLUSIONS Results of this study show variations in CT imaging for treatment planning practice at the national level which call for optimization of procedures.
Collapse
Affiliation(s)
- Ana Božanić
- Medical Physics and Radiation Protection Department, Clinical Hospital Centre Rijeka, Krešimirova 42, Rijeka, Croatia; Medical Physics and Biophysics Department, Medical Faculty, University of Rijeka, Braće Branchetta 20, Rijeka, Croatia.
| | - Doris Šegota
- Medical Physics and Radiation Protection Department, Clinical Hospital Centre Rijeka, Krešimirova 42, Rijeka, Croatia
| | - Dea Dundara Debeljuh
- Medical Physics and Radiation Protection Department, Clinical Hospital Centre Rijeka, Krešimirova 42, Rijeka, Croatia; Medical Physics and Biophysics Department, Medical Faculty, University of Rijeka, Braće Branchetta 20, Rijeka, Croatia; Radiology Department, General Hospital Pula, Santiorova 24a, Pula, Croatia
| | - Manda Švabić Kolacio
- Medical Physics and Radiation Protection Department, Clinical Hospital Centre Rijeka, Krešimirova 42, Rijeka, Croatia
| | - Đeni Smilović Radojčić
- Medical Physics and Radiation Protection Department, Clinical Hospital Centre Rijeka, Krešimirova 42, Rijeka, Croatia; Medical Physics and Biophysics Department, Medical Faculty, University of Rijeka, Braće Branchetta 20, Rijeka, Croatia
| | - Katarina Ružić
- Department of Medical Physics, The University Hospital Centre Zagreb, Kišpatićeva 12, Zagreb, Croatia
| | - Mirjana Budanec
- University Clinical Hospital Center Sestre Milosrdnice, Department of Medical Physics, Vinogradska 29, Zagreb, Croatia
| | - Mladen Kasabašić
- Osijek University Hospital, Department of Medical Physics, Osijek, Josipa Huttlera 4, Croatia
| | - Darijo Hrepić
- Department of Medical Physics, University Hospital of Split, Spinčićeva 1, Split, Croatia
| | - Petra Valković Zujić
- Radiology Department, University Hospital Rijeka, Krešimirova 42, Rijeka, Croatia; Radiology Department, Medical Faculty, University of Rijeka, Braće Branchetta 20, Rijeka, Croatia
| | - Marco Brambilla
- Department of Medical Physics, Azienda Ospedaliero Universitaria Maggiore della Carità, Novara, Italy
| | - Mannudeep K Kalra
- Massachusetts General Hospital, Boston, MA, USA; Harvard Medical School, Boston, MA, USA
| | - Slaven Jurković
- Medical Physics and Radiation Protection Department, Clinical Hospital Centre Rijeka, Krešimirova 42, Rijeka, Croatia; Medical Physics and Biophysics Department, Medical Faculty, University of Rijeka, Braće Branchetta 20, Rijeka, Croatia
| |
Collapse
|
4
|
Karim M, Harun H, Kayun Z, Aljewaw O, Azizan S, Rafiz N, Muhammad N. Paediatric radiation dose and cancer risk associated with body effective diameter during CT thorax examination. Radiat Phys Chem Oxf Engl 1993 2021. [DOI: 10.1016/j.radphyschem.2021.109685] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
5
|
Tan XM, Shah MTBM, Chong SL, Ong YKG, Ang PH, Zakaria NDB, Lee KP, Pek JH. Differences in radiation dose for computed tomography of the brain among pediatric patients at the emergency departments: an observational study. BMC Emerg Med 2021; 21:106. [PMID: 34551720 PMCID: PMC8456576 DOI: 10.1186/s12873-021-00502-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2021] [Accepted: 09/13/2021] [Indexed: 12/13/2022] Open
Abstract
BACKGROUND Computed tomography (CT) is associated with a risk of cancer development. Strategies to reduce radiation doses vary between centers. We compared radiation doses of CT brain studies between pediatric and general emergency departments (EDs), and determine the proportion studies performed within the reference levels recommended by the International Commission on Radiological Protection (ICRP). METHODS A retrospective review was carried out in a healthcare network consisting of one pediatric ED and three general hospital EDs. Pediatric patients less than 16 years old with CT brain studies performed between 1 January 2015 and 31 December 2018 were included. Information on demographic, diagnosis, volume-averaged computed-tomography dose index and dose length product (DLP) were collected. Effective dose was then calculated from DLP using conversion factors, termed k-coefficients which were derived using a 16 cm head CT dose phantom. RESULTS Four hundred and seventy-nine CT brain studies were performed - 379 (79.1%) at the pediatric ED. Seizure (149, 31.1%), head injury (147, 30.7%) and altered mental status (44, 9.2%) were the top three ED diagnoses. The median effective dose estimates were higher in general than pediatric EDs, particularly for those aged > 3 to ≤6 years old [1.57 mSv (IQR 1.42-1.79) versus 1.93 mSv (IQR 1.51-2.28), p = 0.047], > 6 to ≤10 years old [1.43 mSv (IQR 1.27-1.67) versus 1.94 mSv (IQR 1.61-2.59), p = 0.002) and > 10 years old (1.68 mSv (IQR 1.32-1.72) versus 2.03 mSv (IQR 1.58-2.88), p < 0.001). Overall, 233 (48.6%) and 13 (2.7%) studies were within the reference levels recommended by ICRP 60 and 103 respectively. CONCLUSIONS Radiation doses for CT brain studies were significantly higher at general EDs and less than half of the studies were within the reference levels recommended by ICRP. The development of diagnostic reference levels (DRLs) as a benchmark and clinical justification for performing CT studies can help reduce the radiation risks in the pediatric population.
Collapse
Affiliation(s)
- Xi Min Tan
- Yong Loo Lin School of Medicine, National University of Singapore, 10 Medical Dr, Singapore, 117597, Singapore
| | | | - Shu-Ling Chong
- Department of Emergency Medicine, KK Women's and Children's Hospital, 100 Bukit Timah Rd, Singapore, 229899, Singapore
| | - Yong-Kwang Gene Ong
- Department of Emergency Medicine, KK Women's and Children's Hospital, 100 Bukit Timah Rd, Singapore, 229899, Singapore
| | - Peck Har Ang
- Accident and Emergency Department, Changi General Hospital, 2 Simei Street 3, Singapore, 529889, Singapore
| | - Nur Diana Bte Zakaria
- Department of Emergency Medicine, Singapore General Hospital, Outram Rd, Singapore, 169608, Singapore
| | - Khai Pin Lee
- Department of Emergency Medicine, KK Women's and Children's Hospital, 100 Bukit Timah Rd, Singapore, 229899, Singapore
| | - Jen Heng Pek
- Department of Emergency Medicine, Sengkang General Hospital, 110 Sengkang E Way, Singapore, 544886, Singapore.
| |
Collapse
|
6
|
Zalokar N, Žager Marciuš V, Mekiš N. Establishment of national diagnostic reference levels for radiotherapy computed tomography simulation procedures in Slovenia. Eur J Radiol 2020; 127:108979. [PMID: 32302897 DOI: 10.1016/j.ejrad.2020.108979] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2019] [Revised: 02/25/2020] [Accepted: 03/25/2020] [Indexed: 11/28/2022]
Abstract
PURPOSE To propose national diagnostic reference levels (DRLs) for radiotherapy (RT) computed tomography (CT) localization purposes, compare both CT units used in the largest RT department in the country and to compare gathered results with other published DRLs in order to discover any need of optimization. METHODS In total, 1631 patient data (time spend of 4 months) regarding sex, examination type, total dose-length product (DLP) and CTDIvol was collated on two CT units. Those simulation procedures account for more than 80 % of all simulation procedures performed nationwide. Then, total DLP and CTDIvol was calculated and mean, median and 3rd quartile for both units together were presented to determine national DRLs for simulation procedures. The same data was later compared between both units to discover any potential need for optimization. RESULTS 3rd quartile values of DLP for abdomen, breast, chest, head, head and neck, pelvis and spine were 1116.2, 606.6, 832.4, 1942.4, 969.2, 677.1 and 1042.4 mGy∙cm, respectively. 3rd quartile CTDIvol values for the same sequence of procedures were 18.7, 13.3, 19.2, 76.9, 22.6, 17.9 and 22.2 mGy, respectively. Among the two units, the mentioned dose values were on average significantly higher on one CT unit than on the other unit. CONCLUSIONS When comparing collected dose values with other studies, RT CT DRLs showed that radiation doses from our institution were similar or even lower. Some variations were found between both CT units in certain protocols, so exposure parameters should be reviewed and optimized.
Collapse
Affiliation(s)
- Nika Zalokar
- University of Ljubljana, Faculty of Health Sciences, Medical Imaging and Radiotherapy Department, Zdravstvena pot 5, 1000, Ljubljana, Slovenia
| | - Valerija Žager Marciuš
- University of Ljubljana, Faculty of Health Sciences, Medical Imaging and Radiotherapy Department, Zdravstvena pot 5, 1000, Ljubljana, Slovenia; Institute of Oncology Ljubljana, Teleradiotherapy Department, Zaloška cesta 2, 1000 Ljubljana, Slovenia
| | - Nejc Mekiš
- University of Ljubljana, Faculty of Health Sciences, Medical Imaging and Radiotherapy Department, Zdravstvena pot 5, 1000, Ljubljana, Slovenia.
| |
Collapse
|