1
|
Dezhakam E, Tavakkol M, Kafili T, Nozohouri E, Naseri A, Khalilzadeh B, Rahbarghazi R. Electrochemical and optical (bio)sensors for analysis of antibiotic residuals. Food Chem 2024; 439:138145. [PMID: 38091787 DOI: 10.1016/j.foodchem.2023.138145] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2023] [Revised: 10/31/2023] [Accepted: 12/03/2023] [Indexed: 01/10/2024]
Abstract
Antibiotic residuals in foods may lead to crucial health and safety issues in the human body. Rapid and in-time analysis of antibiotics using simple and sensitive techniques is in high demand. Among the most commonly applicable modalities, chromatography-based techniques like HPLC and LC-MS, along with immunological approaches, particularly ELISA have been exampled in the analysis of antibiotics. Despite being highly sensitive, these methods are considerably time-consuming, thus the presence of skilled personnel and costly equipment is essential. Nanomaterial-based (bio)sensors, however, are de novo analytical equipment with some beneficial characteristics, such as simplicity, low price, on-site, high accuracy, and sensitivity for the detection of analytes. This review aimed to collect the latest developments in NM-based sensors and biosensors for the observation of highly used antibiotics like Vancomycin (Van), Linezolid (Lin), and Clindamycin (Clin). The current challenges and developmental perspectives are also debated in detail for future research directions.
Collapse
Affiliation(s)
- Ehsan Dezhakam
- Pharmaceutical Analysis Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Mohammad Tavakkol
- School of Chemistry, University College of Science, University of Tehran, Tehran, Iran
| | - Taha Kafili
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Ehsan Nozohouri
- Department of Pharmaceutical Sciences, Jerry H. Hodge School of Pharmacy, Texas Tech University Health Sciences Center (TTUHSC), Amarillo, TX, USA
| | - Abdolhosein Naseri
- Department of Analytical Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.
| | - Balal Khalilzadeh
- Stem Cell Research Center, Tabriz University of Medical Sciences, Tabriz, Iran; Hematology and Oncology Research Center, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Reza Rahbarghazi
- Department of Applied Cell Sciences, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran.
| |
Collapse
|
2
|
Cheng X, Ma J, Su J. An Overview of Analytical Methodologies for Determination of Vancomycin in Human Plasma. Molecules 2022; 27:molecules27217319. [PMID: 36364147 PMCID: PMC9658014 DOI: 10.3390/molecules27217319] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2022] [Revised: 10/12/2022] [Accepted: 10/26/2022] [Indexed: 11/22/2022] Open
Abstract
Vancomycin is regarded as the last resort of defense for a wide range of infections due to drug resistance and toxicity. The detection of vancomycin in plasma has always aroused particular concern because the performance of the assay affects the clinical treatment outcome. This article reviews various methods for vancomycin detection in human plasma and analyzes the advantages and disadvantages of each technique. Immunoassay has been the first choice for vancomycin concentration monitoring due to its simplicity and practicality, occasionally interfered with by other substances. Chromatographic methods have mainly been used for scientific research due to operational complexity and the particular requirement of the instrument. However, the advantages of a small amount of sample needed, high sensitivity, and specificity makes chromatography irreplaceable. Other methods are less commonly used in clinical applications because of the operational feasibility, clinical application, contamination, etc. Simplicity, good performance, economy, and environmental friendliness have been points of laboratory methodological concern. Unfortunately, no one method has met all of the elements so far.
Collapse
Affiliation(s)
| | | | - Jianrong Su
- Correspondence: or ; Tel.: +86-188-1169-5991
| |
Collapse
|
3
|
Smartphone-based digital image colorimetry for the determination of vancomycin in drugs. MONATSHEFTE FUR CHEMIE 2022. [DOI: 10.1007/s00706-022-02964-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
AbstractA simple smartphone-based digital image colorimetry is proposed for the determination of vancomycin in drugs. The analytical method relied on the reaction of vancomycin with copper(II) in ethanol–water medium with pH 4.3. The reaction resulted in the formation of a blue–grey complex, presenting an absorption maximum at 555 nm. A mobile application was used for smartphone-based analysis to decompose the individual channels of the colour model representations. The determination was performed using three smartphones followed by a comparison of the outcomes with spectrophotometric measurements. The most optimal analytical parameters were achieved for the H channel. The linear ranges obtained for the smartphone-based method proved to be comparable to the spectrophotometric range of 0.044–1.500 g dm−3 and were 0.049–1.500 g dm−3, 0.057–1.500 g dm−3, and 0.040–1.500 g dm−3 for Smartphones 1–3, respectively. Moreover, the determined coefficients of variance (CV, n = 9) and limits of detection (LOD) were 2.3% and 0.015 g dm−3, 6.2% and 0.017 g dm−3, and 2.5% and 0.012 g dm−3, respectively. Whereas for spectrophotometry, the obtained precision, CV was of 0.9% and a LOD of 0.013 g dm−3. The accuracy of the method was verified using model samples, generally the results were obtained with accuracy better than 10.9% (relative error). The method was applied to the determination of vancomycin in drugs. The results obtained by smartphone-based colorimetry did not differ from the expected values for more than 2.6%, were consistent with each other and with the results of spectrophotometric determinations.
Graphical abstract
Collapse
|
4
|
Sabzehmeidani MM, Kazemzad M. Quantum dots based sensitive nanosensors for detection of antibiotics in natural products: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 810:151997. [PMID: 34848263 DOI: 10.1016/j.scitotenv.2021.151997] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 11/09/2021] [Accepted: 11/23/2021] [Indexed: 05/18/2023]
Abstract
Residual antibiotics in food products originated from administration of the antibiotics to animals may be accumulated through food metabolism in the human body and endanger safety and health. Thus, developing a prompt and accurate way for detection of antibiotics is a crucial issue. The zero-dimensional fluorescent probes including metals based, carbon and graphene quantum dots (QDs), are highly sensitive materials to use for the detection of a wide range of antibiotics in natural products. These QDs demonstrate unique optical properties like tunable photoluminescence (PL) and excitation-wavelength dependent emission. This study investigates the trends related to carbon and metal based QDs preparation and modification, and their diverse detection application. We discuss the performance of QDs based sensors application in various detection systems such as photoluminescence, photoelectrochemical, chemiluminescence, electrochemiluminescence, colorimetric, as well as describing their working principles in several samples. The detecting mechanism of a QDs-based sensor is dependent on its properties and specific interactions with particular antibiotics. This review also tries to describe environmental application and future perspective of QDs for antibiotics detection.
Collapse
Affiliation(s)
| | - Mahmood Kazemzad
- Department of Energy, Materials and Energy Research Center, Tehran 14155-477, Iran.
| |
Collapse
|
5
|
Iranifam M, Dadashi Z. Chemiluminescence determination of vancomycin by using NiS nanoparticles-luminol-O 2 system. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 267:120489. [PMID: 34688148 DOI: 10.1016/j.saa.2021.120489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/10/2021] [Revised: 10/02/2021] [Accepted: 10/07/2021] [Indexed: 06/13/2023]
Abstract
In this research, NiS nanoparticles (NPs) were produced using a hydrothermal technique and characterized by several spectroscopic methods. Here, for the first time, it was shown that NiS NPs could be exploited as a nanocatalyst in a chemiluminescence (CL) reaction. Here, it was introduced that NiS NPs could intensify luminol-O2 CL reaction, remarkably. Besides, it was shown that vancomycin (VAN) suppresses the CL intensity of NiS NPs-luminol-O2 reaction. By exploiting the results obtained, a new and straightforward CL method was developed for the measurement of VAN. The linear concentration range of the CL method was 4.00 × 10-6 - 1.00 × 10-3 mol L-1. The limit of detection (LOD) was equal to 1.40 × 10-6 mol L-1 and the relative standard deviation (RSD) of the CL method was 3.00% (n = 6) for the determination of 8.00 × 10-5 mol L-1 VAN. The established CL method was applied to quantify VAN in the injection and spiked human serum.
Collapse
Affiliation(s)
- Mortaza Iranifam
- Department of Chemistry, Faculty of Science, University of Maragheh, Maragheh, Iran.
| | - Zahra Dadashi
- Department of Chemistry, Faculty of Science, University of Maragheh, Maragheh, Iran
| |
Collapse
|
6
|
Iranifam M, Toolooe Gardeh Rasht M, Al Lawati HAJ. CuS nanoparticles-enhanced luminol-O 2 chemiluminescence reaction used for determination of paracetamol and vancomycin. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2021; 261:120038. [PMID: 34118521 DOI: 10.1016/j.saa.2021.120038] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/28/2021] [Revised: 05/25/2021] [Accepted: 05/28/2021] [Indexed: 06/12/2023]
Abstract
A new chemiluminescence (CL) method was proposed to measure two widely used drugs, including paracetamol (PCM) and vancomycin (VAN). The CL reaction used was the CuS nanoparticles (CuS NPs)-luminol-O2 system. In this system, CuS NPs played the role of catalyst and increased the CL intensity. CuS NPs were easily synthesized by quick-precipitation. CuS NPs were characterized by spectroscopic techniques, and the mean size of NPs was estimated to be about 9 nm. In the developed CL methods, PCM and VAN decreased the CL intensity. In the proposed method, the linear concentration ranges were 4.0 × 10-5-4.0 × 10-4 mol L-1 of PCM and 2.0 × 10-5-6.0 × 10-4 mol L-1 of VAN. The limit of detections were 2.9 × 10-5 mol L-1 and 8.9 × 10-6 mol L-1 for PCM and VAN, respectively. The relative standard deviations (RSD) of the CL method were 2.99 and 4.31 (n = 6) for the determination of 3.0 × 10-4 mol L-1 PCM and VAN, respectively. It was also shown that the CL methods can measure PCM and VAN concentrations in various real samples.
Collapse
Affiliation(s)
- Mortaza Iranifam
- Department of Chemistry, Faculty of Science, University of Maragheh, Maragheh, Iran.
| | | | - Haider A J Al Lawati
- Department of Chemistry, College of Science, Sultan Qaboos University, Box 36, Al-Khod, 123, Oman
| |
Collapse
|
7
|
Nano optical and electrochemical sensors and biosensors for detection of narrow therapeutic index drugs. Mikrochim Acta 2021; 188:411. [PMID: 34741213 DOI: 10.1007/s00604-021-05003-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2021] [Accepted: 08/24/2021] [Indexed: 01/02/2023]
Abstract
For the first time, a comprehensive review is presented on the quantitative determination of narrow therapeutic index drugs (NTIDs) by nano optical and electrochemical sensors and biosensors. NTIDs have a narrow index between their effective doses and those at which they produce adverse toxic effects. Therefore, accurate determination of these drugs is very important for clinicians to provide a clear judgment about drug therapy for patients. Routine analytical techniques have limitations such as being expensive, laborious, and time-consuming, and need a skilled user and therefore the nano/(bio)sensing technology leads to high interest.
Collapse
|
8
|
Mu F, Zhou X, Fan F, Chen Z, Shi G. A fluorescence biosensor for therapeutic drug monitoring of vancomycin using in vivo microdialysis. Anal Chim Acta 2021; 1151:338250. [DOI: 10.1016/j.aca.2021.338250] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2020] [Revised: 01/19/2021] [Accepted: 01/20/2021] [Indexed: 12/26/2022]
|
9
|
Rahimpour E, Khoubnasabjafari M, Hosseini MB, Jouyban A. Copper nanocluster-based sensor for determination of vancomycin in exhaled breath condensate: A synchronous fluorescence spectroscopy. J Pharm Biomed Anal 2021; 196:113906. [PMID: 33486448 DOI: 10.1016/j.jpba.2021.113906] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2020] [Revised: 01/06/2021] [Accepted: 01/14/2021] [Indexed: 12/01/2022]
Abstract
A synchronous fluorescence spectroscopy (SFS) nanoprobe is developed for the determination of vancomycin in exhaled breath condensate (EBC) samples. The synthesized nanoprobe is copper nanoclusters (Cu NCs) and its SFS peak is located at 405 nm with Δλ = 80. The affinity of Cu NCs to complex formation with vancomycin results in blocking non-radiative e-/h+ recombination defect sites on the surface of NCs and consequently enhancing the SFS signal intensity. Central composite design and response surface methodology is used for the optimization of reaction conditions. Under the optimized conditions, a linear relationship is found between the SFS intensity and the concentration of vancomycin in the range of 0.1-8 μg/mL. The validated method is applied for the determination of vancomycin in EBC of newborns receiving vancomycin treatment.
Collapse
Affiliation(s)
- Elaheh Rahimpour
- Pharmaceutical Analysis Research Center and Faculty of Pharmacy, Tabriz University of Medical Sciences, Tabriz, 5165665811, Iran; Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, 5165665811, Iran
| | - Maryam Khoubnasabjafari
- Tuberculosis and Lung Diseases Research Center and Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, 5165665811, Iran; Immunology Research Center, Tabriz University of Medical Sciences, Tabriz, 5165665811, Iran
| | | | - Abolghasem Jouyban
- Food and Drug Safety Research Center, Tabriz University of Medical Sciences, Tabriz, 5165665811, Iran; Kimia Idea Pardaz Azarbayjan (KIPA) Science Based Company, Tabriz University of Medical Sciences, Tabriz, 5165665811, Iran.
| |
Collapse
|
10
|
Dong Y, Li F, Wang Y. Low-Dimension Nanomaterial-Based Sensing Matrices for Antibiotics Detection: A Mini Review. Front Chem 2020; 8:551. [PMID: 32793548 PMCID: PMC7393977 DOI: 10.3389/fchem.2020.00551] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2020] [Accepted: 05/28/2020] [Indexed: 12/28/2022] Open
Abstract
Antibiotics, a kind of secondary metabolite with antipathogen effects as well as other properties, are produced by microorganisms (including bacterium, fungi, and actinomyces) or higher animals and plants during their lives. Furthermore, as a chemical, an antibiotic can disturb the developmental functions of other living cells. Moreover, it is impossible to avoid its pervasion into all kinds of environmental media via all kinds of methods, and it thus correspondingly becomes a trigger for environmental risks. As described above, antibiotics are presently deemed as a new type of pollution, with their content in media (for example, water, or food) as the focus. Due to their special qualities, nanomaterials, the most promising sensing material, can be adopted to produce sensors with extraordinary detection performance and good stability that can be applied to detection in complicated materials. For low-dimensional (LD) nanomaterials, the quantum size effect, and dielectric confinement effect are particularly strong. Therefore, they are most commonly applied in the detection of antibiotics. This article focuses on the influence of LD nanomaterials on antibiotics detection, summarizes the application of LD nanomaterials in antibiotics detection and the theorem of sensors in all kinds of antibiotics detection, illustrates the approaches to optimizing the sensitivity of sensors, such as mixture and modification, and also discusses the trend of the application of LD nanomaterials in antibiotics detection.
Collapse
Affiliation(s)
- Yucan Dong
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China.,Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Fengting Li
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China.,Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| | - Ying Wang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, China.,Shanghai Institute of Pollution Control and Ecological Security, Shanghai, China
| |
Collapse
|
11
|
Orooji Y, Haddad Irani-Nezhad M, Hassandoost R, Khataee A, Rahim Pouran S, Joo SW. Cerium doped magnetite nanoparticles for highly sensitive detection of metronidazole via chemiluminescence assay. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2020; 234:118272. [PMID: 32229321 DOI: 10.1016/j.saa.2020.118272] [Citation(s) in RCA: 71] [Impact Index Per Article: 17.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 03/14/2020] [Accepted: 03/15/2020] [Indexed: 06/10/2023]
Abstract
Cerium doped magnetite nanoparticle (CDM) was synthesized via a co-precipitation method and used as the co-reactant of luminol-K3Fe(CN)6 chemiluminescent system. The physical-chemical features of CDM were studied by XPS, XRD, HRTEM, FESEM, VSM, BET, and FTIR analyses. This simple and highly sensitive nanoprobe enabled the determination of minor concentrations of metronidazole (MNZ). Owing to the quenching efficacy of MNZ in the studied chemiluminescence system, a linear range of 3.47 × 10-6-9.37 × 10-5 mol/L was obtained with a limit of detection of 3.91 × 10-7 mol/L. This biosensor was used for MNZ detection in human serum samples, which was highly efficient. The outcomes of this study give credit to the proposed biosensor to be applied for detection of MNZ in biological samples.
Collapse
Affiliation(s)
- Yasin Orooji
- College of Materials Science and Engineering, Nanjing Forestry University, No. 159, Longpan Road, Nanjing, 210037, Jiangsu, People's Republic of China; Co-Innovation Center of Efficient Processing and Utilization of Forest Resources, Nanjing Forestry University, Nanjing 210037, China
| | - Mahsa Haddad Irani-Nezhad
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran
| | - Ramin Hassandoost
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran
| | - Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran; Department of Environmental Engineering, Gebze Technical University, 41400 Gebze, Turkey; Institute of Research and Development, Duy Tan University, Da Nang 550000, Viet Nam.
| | - Shima Rahim Pouran
- Department of Biology, Faculty of Science, University of Mohaghegh Ardabili, P.O. Box 179, Ardabil, Iran
| | - Sang Woo Joo
- School of Mechanical Engineering, Yeungnam University, Gyeongsan 712-749, South Korea.
| |
Collapse
|
12
|
Liu M, Yang ZH, Li GH. A Novel Method for the Determination of Vancomycin in Serum by High-Performance Liquid Chromatography-Tandem Mass Spectrometry and Its Application in Patients with Diabetic Foot Infections. Molecules 2018; 23:E2939. [PMID: 30423820 PMCID: PMC6278353 DOI: 10.3390/molecules23112939] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 11/06/2018] [Accepted: 11/06/2018] [Indexed: 01/15/2023] Open
Abstract
A novel, precise, and accurate high-performance liquid chromatography-tandem mass spectrometry (Q-trap-MS) method was developed, optimized, and validated for determination of vancomycin in human serum using norvancomycin as an internal standard. Effect of different parameters on the analysis was evaluated. ZORBAX SB-C18 column (150 × 4.6 mm, 5 μm) using water (containing 0.1% formic acid, v/v)⁻acetonitrile (containing 0.1% formic acid, v/v) as a mobile phase was chosen. The calibration curve was linear over the concentration ranges of 1 to 2000 ng/mL for vancomycin. The limit of detection (LOD) and limit of quantification (LOQ) for vancomycin were 0.3 and 1.0 ng/mL. Recoveries were between 87.2 and 102.3%, which gave satisfactory precision. A total of 100 serum samples (from 50 patients with diabetic foot proven Gram-positive infection and 50 nondiabetic patients with pneumonia requiring hospitalization and antibiotic therapy) were analyzed by this method. The trough vancomycin concentrations of diabetic foot infection (DFI) patients and nondiabetic patients were 8.20 ± 2.83 μg/mL (range: 4.80⁻14.2 μg/mL) and 15.80 ± 5.43 μg/mL (range: 8.60⁻19.5 μg/mL), respectively. The method is sensitive, precise, and reproducible, it could be applied for routine laboratory analysis of vancomycin in serum samples.
Collapse
Affiliation(s)
- Min Liu
- Department of Pharmacy, National Cancer Center/National Clinical Research Center for Cancer/Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
| | - Zhi-Hui Yang
- Institute of Aviation Medicine of Air Force, Beijing 100142, China.
| | - Guo-Hui Li
- Department of Pharmacy, National Cancer Center/National Clinical Research Center for Cancer/Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing 100021, China.
| |
Collapse
|
13
|
Ng SM, Wu X, Khyasudeen MF, Nowakowski PJ, Tan HS, Xing B, Yeow EKL. Vancomycin Determination by Disrupting Electron-Transfer in a Fluorescence Turn-On Squaraine-Anthraquinone Triad. ACS Sens 2018; 3:1156-1163. [PMID: 29792330 DOI: 10.1021/acssensors.8b00188] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
A highly sensitive and selective probe for Vancomycin (Van) in aqueous and serum samples is developed in this study. The probe is based on a triad consisting of a near-infrared squaraine dye (Seta-640) conjugated to two anthraquinone molecules via Lys-d-Ala-d-Ala peptides. In the absence of Van, the close proximity and efficient electron-transfer from the excited Seta-640 dye to anthraquinone result in significant fluorescence quenching of the dye ("off"-state). When Van is added, the antibiotic molecules bind with high affinity to the -d-Ala-d-Ala ligands in a 2:1 stoichiometry (Van:triad), resulting in fluorescence recovery that is as high as 30 times ("on"-state). Even though bound Van enhances the fluorescence by reducing the rate of (intrinsic) polarity-induced nonradiative decay process, this effect plays only a minor role. Instead, the main reason behind the observed fluorescence recovery after drug binding is the effective inhibition of electron-transfer; plausibly arising from a steric-induced lengthening of the spatial separation between electron donor and acceptor. The probe has detection limits of 7.0 and 96.9 nM in buffer and human serum, respectively, operates in the clinically relevant range, is insensitive to Van crystalline degradation product (CDP-1), and is easy to operate by using a commonly available fluorescence spectrometer.
Collapse
Affiliation(s)
- Shue Mei Ng
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371
| | - Xiangyang Wu
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371
| | - M. Faisal Khyasudeen
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371
| | - Paweł J. Nowakowski
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371
| | - Howe-Siang Tan
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371
| | - Bengang Xing
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371
| | - Edwin K. L. Yeow
- Division of Chemistry and Biological Chemistry, School of Physical and Mathematical Sciences, Nanyang Technological University, 21 Nanyang Link, Singapore 637371
| |
Collapse
|
14
|
Timofeeva II, Vakh CS, Bulatov AV, Worsfold PJ. Flow analysis with chemiluminescence detection: Recent advances and applications. Talanta 2017; 179:246-270. [PMID: 29310229 DOI: 10.1016/j.talanta.2017.11.007] [Citation(s) in RCA: 43] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/29/2017] [Revised: 11/03/2017] [Accepted: 11/04/2017] [Indexed: 10/18/2022]
Abstract
This article highlights the most important developments in flow analysis with chemiluminescence (CL) detection, describing different flow systems that are compatible with CL detection, detector designs, commonly applied CL reactions and approaches to sample treatment. Recent applications of flow analysis with CL detection (focusing on outputs published since 2010) are also presented. Applications are classified by sample matrix, covering foods and beverages, environmental matrices, pharmaceuticals and biological fluids. Comprehensive tables are provided for each area, listing the specific sample matrix, CL reaction used, linear range, limit of detection and sample treatment for each analyte. Finally, recent and emerging trends in the field are also discussed.
Collapse
Affiliation(s)
- Irina I Timofeeva
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, St.Petersburg State University, SPbSU, SPbU, 7/9 Universitetskayanab., St. Petersburg 199034, Russia.
| | - Christina S Vakh
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, St.Petersburg State University, SPbSU, SPbU, 7/9 Universitetskayanab., St. Petersburg 199034, Russia
| | - Andrey V Bulatov
- Department of Analytical Chemistry, Institute of Chemistry, Saint-Petersburg University, St.Petersburg State University, SPbSU, SPbU, 7/9 Universitetskayanab., St. Petersburg 199034, Russia
| | - Paul J Worsfold
- School of Geography, Earth and Environmental Sciences and Biogeochemistry Research Centre, Plymouth University, Plymouth, Devon PL4 8AA, UK
| |
Collapse
|
15
|
Chemiluminescence reactions enhanced by silver nanoparticles and silver alloy nanoparticles: Applications in analytical chemistry. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2016.05.018] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
16
|
Iranifam M. Analytical applications of chemiluminescence systems assisted by carbon nanostructures. Trends Analyt Chem 2016. [DOI: 10.1016/j.trac.2015.08.018] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
17
|
Khataee A, Lotfi R, Hasanzadeh A, Iranifam M, Joo SW. A flow injection chemiluminescence method for determination of nalidixic acid based on KMnO₄-morin sensitized with CdS quantum dots. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2016; 154:243-251. [PMID: 26534888 DOI: 10.1016/j.saa.2015.10.039] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/01/2015] [Revised: 10/20/2015] [Accepted: 10/25/2015] [Indexed: 06/05/2023]
Abstract
A simple and sensitive flow injection chemiluminescence (CL) method was developed for determination of nalidixic acid by application of CdS quantum dots (QDs) in KMnO4-morin CL system in acidic medium. Optical and structural features of L-cysteine capped CdS quantum dots which were synthesized via hydrothermal approach were investigated using X-ray diffraction (XRD), scanning electron microscopy (SEM), photoluminescence (PL), and ultraviolet-visible (UV-Vis) spectroscopy. Moreover, the potential mechanism of the proposed CL method was described using the results of the kinetic curves of CL systems, the spectra of CL, PL and UV-Vis analyses. The CL intensity of the KMnO4-morin-CdS QDs system was considerably increased in the presence of nalidixic acid. Under the optimum condition, the enhanced CL intensity was linearly proportional to the concentration of nalidixic acid in the range of 0.0013 to 21.0 mg L(-1), with a detection limit of (3σ) 0.003 mg L(-1). Also, the proposed CL method was utilized for determination of nalidixic acid in environmental water samples, and commercial pharmaceutical formulation to approve its applicability. Furthermore, corona discharge ionization ion mobility spectrometry (CD-IMS) method was utilized for determination of nalidixic acid and the results of real sample analysis by two proposed methods were compared. Comparison the analytical features of these methods represented that the proposed CL method is preferable to CD-IMS method for determination of nalidixic acid due to its high sensitivity and precision.
Collapse
Affiliation(s)
- Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran.
| | - Roya Lotfi
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran
| | - Aliyeh Hasanzadeh
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran
| | - Mortaza Iranifam
- Department of Chemistry, Faculty of Science, University of Maragheh, 55181-83111 Maragheh, Iran
| | - Sang Woo Joo
- School of Mechanical Engineering, Yeungnam University, 712-749 Gyeongsan, South Korea.
| |
Collapse
|
18
|
Wendling A, Mar D, Wischmeier N, Anderson D, McIff T. Combination of modified mixing technique and low frequency ultrasound to control the elution profile of vancomycin-loaded acrylic bone cement. Bone Joint Res 2016; 5:26-32. [PMID: 26843512 PMCID: PMC4852785 DOI: 10.1302/2046-3758.52.2000412] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/05/2022] Open
Abstract
OBJECTIVES The objective of this study was to determine if combining variations in mixing technique of antibiotic-impregnated polymethylmethacrylate (PMMA) cement with low frequency ultrasound (LFUS) improves antibiotic elution during the initial high phase (Phase I) and subsequent low phase (Phase II) while not diminishing mechanical strength. METHODS Three batches of vancomycin-loaded PMMA were prepared with different mixing techniques: a standard technique; a delayed technique; and a control without antibiotic. Daily elution samples were analysed using flow injection analysis (FIA). Beginning in Phase II, samples from each mix group were selected randomly to undergo either five, 15, 45, or 0 minutes of LFUS treatment. Elution amounts between LFUS treatments were analysed. Following Phase II, compression testing was done to quantify strength. A-priori t-tests and univariate ANOVAs were used to compare elution and mechanical test results between the two mix groups and the control group. RESULTS The delayed technique showed a significant increase in elution on day one compared with the standard mix technique (p < 0.001). The transition point from Phase I to Phase II occurred on day ten. LFUS treatments significantly increased elution amounts for all groups above control. Delayed technique resulted in significantly higher elution amounts for the five-minute- (p = 0.004) and 45-minute- (p < 0.001) duration groups compared with standard technique. Additionally, the correlations between LFUS duration and total elution amount for both mix techniques were significant (p = 0.03). Both antibiotic-impregnated groups exhibited a significant decrease in offset yield stress compared with the control group (p < 0.001), however, their lower 95% confidence intervals were all above the 70 MPa limit defined by International Standards Organization (ISO) 5833-2 reference standard for acrylic bone cement. CONCLUSION The combination of a delayed mix technique with LFUS treatments provides a reasonable means for increasing both short- and long-term antibiotic elution without affecting mechanical strength.Cite this article: Dr. T. McIff. Combination of modified mixing technique and low frequency ultrasound to control the elution profile of vancomycin-loaded acrylic bone cement. Bone Joint Res 2016;5:26-32. doi: 10.1302/2046-3758.52.2000412.
Collapse
Affiliation(s)
- A Wendling
- Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - D Mar
- Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - N Wischmeier
- Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - D Anderson
- Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas City, Kansas, USA
| | - T McIff
- Department of Orthopedic Surgery, University of Kansas Medical Center, Kansas City, Kansas, USA
| |
Collapse
|
19
|
Khataee A, Lotfi R, Hasanzadeh A, Iranifam M, Zarei M, Joo SW. Comparison of two methods for selegiline determination: A flow-injection chemiluminescence method using cadmium sulfide quantum dots and corona discharge ion mobility spectrometry. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2016; 153:273-280. [PMID: 26318702 DOI: 10.1016/j.saa.2015.08.036] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/28/2015] [Revised: 08/13/2015] [Accepted: 08/16/2015] [Indexed: 06/04/2023]
Abstract
Two analytical approaches including chemiluminescence (CL) and corona discharge ionization ion mobility spectrometry (CD-IMS) were developed for sensitive determination of selegiline (SG). We found that the CL intensity of the KMnO4-Na2S2O3 CL system was significantly enhanced in the presence of L-cysteine capped CdS quantum dots (QDs). A possible CL mechanism for this CL reaction is proposed. In the presence of SG, the enhanced CL system was inhibited. Based on this inhibition, a simple and sensitive flow-injection CL method was proposed for the determination of SG. Under optimum experimental conditions, the decreased CL intensity was proportional to SG concentration in the range of 0.01 to 30.0 mg L(-1). The detection limit (3σ) was 0.004 mg L(-1). Also, SG was determined using CD-IMS, and under optimum conditions of CD-IMS, calibration curves were linear in the range of 0.15 to 42.0 mg L(-1), with a detection limit (3σ) of 0.03 mg L(-1). The precision of the two methods was calculated by analyzing samples containing 5.0 mg L(-1) of SG (n=11). The relative standard deviations (RSDs%) of the flow-injection CL and CD-IMS methods are 2.17% and 3.83%, respectively. The proposed CL system exhibits a higher sensitivity and precision than the CD-IMS method for the determination of SG.
Collapse
Affiliation(s)
- Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran.
| | - Roya Lotfi
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran
| | - Aliyeh Hasanzadeh
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran
| | - Mortaza Iranifam
- Department of Chemistry, Faculty of Science, University of Maragheh, 55181-83111 Maragheh, Iran
| | - Mahmoud Zarei
- Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran
| | - Sang Woo Joo
- School of Mechanical Engineering, Yeungnam University, 712-749 Gyeongsan, South Korea.
| |
Collapse
|
20
|
Khataee A, Hasanzadeh A, Lotfi R, Pourata R, Joo SW. Determination of dexamethasone by flow-injection chemiluminescence method using capped CdS quantum dots. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2015; 150:63-71. [PMID: 26023057 DOI: 10.1016/j.saa.2015.05.047] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/18/2015] [Revised: 05/14/2015] [Accepted: 05/17/2015] [Indexed: 06/04/2023]
Abstract
L-Cysteine capped CdS quantum dots (QDs) were synthesized through a facile hydrothermal method and characterized by X-ray diffraction (XRD), scanning electron microscopy (SEM), photoluminescence (PL) and UV-Vis spectroscopy. The light emitted from KMnO4-L-cysteine capped CdS QDs reaction in acidic medium was applied as a simple and sensitive chemiluminescence (CL) system for determination of dexamethasone. The CL intensity of KMnO4-L-cysteine capped CdS QDs CL system was remarkably enhanced in the presence of dexamethasone. Under optimum experimental conditions, the enhanced CL intensity was related to dexamethasone concentration in the range of 0.004-25.0 mg L(-1), with the detection limit (3σ) of 0.0013 mg L(-1). The analytical applicability of the proposed CL system was assessed by determining dexamethasone in spiked environmental water samples and pharmaceutical formulation. The analytical performances of proposed flow-injection CL method for the determination of dexamethasone were compared with those obtained by corona discharge ionization ion mobility spectrometry (CD-IMS) method. The proposed CL system exhibits a higher sensitivity and precision than the CD-IMS method for the determination of dexamethasone.
Collapse
Affiliation(s)
- Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran.
| | - Aliyeh Hasanzadeh
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran
| | - Roya Lotfi
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, 51666-16471 Tabriz, Iran
| | - Rahmatollah Pourata
- Department of Chemistry, Faculty of Science, University of Zanjan, 45371-38791 Zanjan, Iran
| | - Sang Woo Joo
- School of Mechanical Engineering, Yeungnam University, 712-749 Gyeongsan, South Korea.
| |
Collapse
|
21
|
|
22
|
Khataee A, Iranifam M, Fathinia M, Nikravesh M. Flow-injection chemiluminescence determination of cloxacillin in water samples and pharmaceutical preparation by using CuO nanosheets-enhanced luminol-hydrogen peroxide system. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2015; 134:210-217. [PMID: 25014643 DOI: 10.1016/j.saa.2014.06.125] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/01/2014] [Revised: 06/11/2014] [Accepted: 06/22/2014] [Indexed: 06/03/2023]
Abstract
In this paper, a rapid and sensitive flow-injection chemiluminescence (flow-CL) system was developed for the determination of cloxacillin sodium in environmental water samples and pharmaceutical preparations. The method was based on the enhancement effect of cloxacillin sodium on the CL reaction of luminal-H₂O₂-CuO nanosheets (NSs) in alkaline medium. The CuO nanosheets were synthesized using a green sonochemical method. The physical properties of the synthesized CuO nanosheets were characterized by X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses. The influences of various experimental factors such as H₂O₂, NaOH, luminol and CuO nanosheets concentrations were investigated. Under the optimum conditions, the enhanced CL intensity was linearly related to the concentration of cloxacillin sodium in the range of the 0.05-30.00 mg L(-1) with a correlation coefficient of 0.995. The corresponding detection limit (3σ) was calculated to be 0.026 mg L(-1). The relative standard deviation (RSD) of the developed method was 2.21% with 11 repeated measurements of 4.00 mg L(-1) cloxacillin sodium. Also, a total analysis time per sample was 30 s which confirmed the rapidity of the proposed method. The analytical applicability of the proposed CL system was assessed by determining cloxacillin sodium in spiked environmental water samples and pharmaceutical preparation. Furthermore, the possible mechanism of CL reaction was discussed.
Collapse
Affiliation(s)
- Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran.
| | - Mortaza Iranifam
- Department of Chemistry, Faculty of Science, University of Maragheh, Maragheh, Iran
| | - Mehrangiz Fathinia
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| | - Mina Nikravesh
- Research Laboratory of Advanced Water and Wastewater Treatment Processes, Department of Applied Chemistry, Faculty of Chemistry, University of Tabriz, Tabriz, Iran
| |
Collapse
|
23
|
Khataee A, Lotfi R, Hasanzadeh A. A novel permanganate–morin–CdS quantum dots flow injection chemiluminescence system for sensitive determination of vancomycin. RSC Adv 2015. [DOI: 10.1039/c5ra14708e] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
The intensity of emitted light from KMnO4−morin−CdS QDs system is described as a novel chemiluminescence (CL) reaction. The CL intensity of this CL system was remarkably enhanced in the presence of vancomycin.
Collapse
Affiliation(s)
- Alireza Khataee
- Research Laboratory of Advanced Water and Wastewater Treatment Processes
- Department of Applied Chemistry
- Faculty of Chemistry
- University of Tabriz
- 51666-16471 Tabriz
| | - Roya Lotfi
- Research Laboratory of Advanced Water and Wastewater Treatment Processes
- Department of Applied Chemistry
- Faculty of Chemistry
- University of Tabriz
- 51666-16471 Tabriz
| | - Aliyeh Hasanzadeh
- Research Laboratory of Advanced Water and Wastewater Treatment Processes
- Department of Applied Chemistry
- Faculty of Chemistry
- University of Tabriz
- 51666-16471 Tabriz
| |
Collapse
|
24
|
Hassani A, Soltani RDC, Karaca S, Khataee A. Preparation of montmorillonite–alginate nanobiocomposite for adsorption of a textile dye in aqueous phase: Isotherm, kinetic and experimental design approaches. J IND ENG CHEM 2015. [DOI: 10.1016/j.jiec.2014.05.034] [Citation(s) in RCA: 71] [Impact Index Per Article: 7.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
25
|
Liang W, Liu S, Liu Z, Li D, Wang L, Hao C, He Y. Electron transfer and fluorescence “turn-off” based CdTe quantum dots for vancomycin detection at nanogram level in aqueous serum media. NEW J CHEM 2015. [DOI: 10.1039/c4nj01764a] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Mode of interaction of GSH-CdTe QDs with vancomycin and the mechanism of the fluorescence “turn-off” process.
Collapse
Affiliation(s)
- Wanjun Liang
- Key Laboratory on Luminescence & Real-Time Analysis
- Ministry of Education
- School of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Shaopu Liu
- Key Laboratory on Luminescence & Real-Time Analysis
- Ministry of Education
- School of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Zhengqing Liu
- Frontier Institute of Chemistry
- Frontier Institute of Science and Technology jointly with College of Science
- Xi'an Jiaotong University
- Xi'an 710054
- P. R. China
| | - Dan Li
- Key Laboratory on Luminescence & Real-Time Analysis
- Ministry of Education
- School of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Linlin Wang
- Key Laboratory on Luminescence & Real-Time Analysis
- Ministry of Education
- School of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Chenxia Hao
- Key Laboratory on Luminescence & Real-Time Analysis
- Ministry of Education
- School of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Youqiu He
- Key Laboratory on Luminescence & Real-Time Analysis
- Ministry of Education
- School of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| |
Collapse
|
26
|
Iranifam M, Khabbaz Kharameh M. Cupric oxide nanoparticles‐enhanced chemiluminescence method for measurement of β‐lactam antibiotics. LUMINESCENCE 2014; 30:625-30. [DOI: 10.1002/bio.2796] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2014] [Revised: 09/08/2014] [Accepted: 09/08/2014] [Indexed: 12/16/2022]
Affiliation(s)
- Mortaza Iranifam
- Department of Chemistry, Faculty of ScienceUniversity of Maragheh Maragheh Iran
| | | |
Collapse
|
27
|
Iranifam M. Analytical applications of chemiluminescence methods for cancer detection and therapy. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.03.010] [Citation(s) in RCA: 52] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|