1
|
Kim PG, Lee A, Shin J, Song E, Koo Y, Sochichiu S, Mohamed DFMS, Choi S, Hong Y, Kwon JH. Increase of the indoor concentration of volatile organic compounds after the use of incense and scented candle in studio apartments determined using passive sampling. CHEMOSPHERE 2024; 359:142344. [PMID: 38754484 DOI: 10.1016/j.chemosphere.2024.142344] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 05/10/2024] [Accepted: 05/14/2024] [Indexed: 05/18/2024]
Abstract
Burning incenses and scented candles may provide harmful chemicals. Although many studies have evaluated volatile organic chemicals emitted by their use and related health risks, extension of our understanding for guiding appropriate use under various use conditions is necessary. In this study, emission characteristics of commercial incenses and scented candles were evaluated in a laboratory chamber using real-time measurement and the time-weighted average exposure concentrations of monoaromatic compounds and monoterpenes were assessed using passive samplers while volunteers living in a studio apartment use them. After burning incense, the average levels of benzene increased from 1.4 to 100 μg m-3. The presence of a wood core in commercial incense products was the main cause of high benzene emission by burning them although the increase in benzene was also influenced by factors such as the brand of the products, the number of incense sticks burned, the duration of each burning session, and ventilation period. Electrical warming of scented candles increased the levels of monoterpenes by factors of 16-30 on average. Considering the emission characteristics found in this study, exposure to benzene and monoterpenes could be mitigated by cautious use of those products in residential areas.
Collapse
Affiliation(s)
- Pil-Gon Kim
- Department of Environmental Education, Mokpo National University, Muan, Jeonnam, 58554, Republic of Korea; Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Arum Lee
- Department of Consumer Science, Chungbuk National University, Cheongju, 28644, Republic of Korea
| | - Jaeho Shin
- Department of Consumer Science, Chungbuk National University, Cheongju, 28644, Republic of Korea
| | - Eugene Song
- Department of Consumer Science, Chungbuk National University, Cheongju, 28644, Republic of Korea
| | - Yerim Koo
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Stefana Sochichiu
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Dana Fahad M S Mohamed
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Soobin Choi
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea
| | - Yongseok Hong
- Department of Environmental Engineering, College of Science and Technology, Korea University Sejong Campus, Sejong, 30019, Republic of Korea
| | - Jung-Hwan Kwon
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
| |
Collapse
|
2
|
Wang Z, Yu T, Ye J, Tian L, Lin B, Leng W, Liu C. A novel low sampling rate and cost-efficient active sampler for medium/long-term monitoring of gaseous pollutants. JOURNAL OF HAZARDOUS MATERIALS 2024; 461:132583. [PMID: 37741205 DOI: 10.1016/j.jhazmat.2023.132583] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 09/14/2023] [Accepted: 09/17/2023] [Indexed: 09/25/2023]
Abstract
Active sampling is a dependable approach for gaseous pollutants monitoring, offering high accuracy and precision that is unaffected by environmental factors such as wind and temperature in comparison to passive sampling. To measure long-term average concentrations while minimizing the use of materials, a reduced sampling rate is necessary. Thus, this study aims to develop a novel low sampling rate (down to 1 mL/min) and cost-efficient active sampler (LASP) for medium/long-term monitoring of gaseous pollutants. The LASP mainly consisted of a syringe pump, a Y-shaped fitting with two one-way valves, and a control unit for intermittent operation. Results showed that LASP can obtain a sampling rate of less than 1 mL/min and sampling rate exhibited a high level of stability. Daily average concentrations measurements for nitrogen dioxide and formaldehyde by LASP had normalized mean biases of 2.8% and 5.2%, respectively. These numbers were - 5.8% and 6.1% for weekly-average samplings. This study demonstrated applications of LASP in real outdoor (daily-average) and indoor (weekly-average) air quality measurements. It worked well with low noise levels, and without interfering with occupants' daily activities. LASP can assist in improving our ability to monitor air quality and pollutants emissions, thereby supporting health research and policy development. ENVIRONMENTAL IMPLICATION: Gaseous air pollution is an important hazardous factor threatening human health. Medium/long-term air quality monitoring is essential for outdoor and indoor air quality assessment and control. However, air sampler for medium/long-term sampling is lacking. This study developed a novel low sampling rate and cost-efficient active sampler and applied it to medium/long-term air sampling. The sampler can work at a sampling rate of less than 1 mL/min. This technology provides a feasible strategy for medium/long-term monitoring of gaseous air pollutants in both environments and emission hotspots.
Collapse
Affiliation(s)
- Zhiyuan Wang
- School of Energy and Environment, Southeast University, Nanjing 210096, China
| | - Tao Yu
- Wuhan Second Ship Design and Research Institute, Wuhan 430205, China
| | - Jin Ye
- School of Energy and Power, Jiangsu University of Science and Technology, Zhenjiang, Jiangsu 212100, China
| | - Lei Tian
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Bencheng Lin
- Tianjin Institute of Environmental and Operational Medicine, Tianjin 300050, China
| | - Wenjun Leng
- Wuhan Second Ship Design and Research Institute, Wuhan 430205, China
| | - Cong Liu
- School of Energy and Environment, Southeast University, Nanjing 210096, China.
| |
Collapse
|
3
|
Pérez Ballesta P, Baù A, Field RA, Woolfenden E. Using the POD sampler for quantitative diffusive (passive) monitoring of volatile and very volatile organics in ambient air: Sampling rates and analytical performance. ENVIRONMENT INTERNATIONAL 2023; 179:108119. [PMID: 37597498 DOI: 10.1016/j.envint.2023.108119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2023] [Revised: 07/24/2023] [Accepted: 07/26/2023] [Indexed: 08/21/2023]
Abstract
POD diffusive samplers loaded with Carbopack X and Carbograph 5TD were exposed to certified calibration mixtures containing a total of 110 different ozone precursor and air toxic compounds. Constant sampling rates were identified for 39 ozone precursors and 33 air toxics. As 9 of these compounds were included in both mixtures, this meant a total of 63 different volatile and very volatile compounds were sampled using the POD with overall expanded uncertainties below 30 % for the sampling rate associated with the whole range of sampling times from 2 to 24 h. Carbograph 5TD exhibited superior performance for diffusive sampling of oxygenated and halogenated compounds in the air toxics mixture, while Carbopack X showed higher sampling efficiencies for aliphatic and aromatic hydrocarbons, as well as halogenated compounds derived from benzene and C2 carbon number hydrocarbons. A model has been developed and applied to estimate sampling rates, primarily for the more volatile and weakly adsorbed compounds, as a function of the collected amount of analyte and the exposure time. For an additional 9 ozone precursors on Carbopack X, and 11 air toxics on Carbograph 5TD, the expanded uncertainties of modelled sampling rates were reduced to below 30 % and have a significantly reduced uncertainty compared to those associated with an averaged sampling rate. The paper provides Freundlich's isotherm parameters for the estimated (modelled) sampling rates and defines a pragmatic approach to their application. It does so by identifying the best sampling time to use for the expected exposure concentrations and associated analyte masses. This allows for expansion of the sampling concentration range from hundreds ng m-3 to mg m-3, while avoiding saturation of the adsorbent. Finally, field measurement comparisons of POD samplers, pumped tube samplers and online gas chromatography (GC), for sampling periods of 3 and 7 days in a semi-rural background area, showed no significant differences between reported concentrations.
Collapse
Affiliation(s)
- P Pérez Ballesta
- European Commission, Joint Research Centre. Directorate C-Energy, Mobility and Climate. Clean Air and Climate Unit, I-21027, Ispra, VA, Italy.
| | - A Baù
- European Commission, Joint Research Centre. Directorate C-Energy, Mobility and Climate. Clean Air and Climate Unit, I-21027, Ispra, VA, Italy
| | - R A Field
- United Nations Environment Programme, 1 Rue Miollis, 75015 Paris, France
| | - E Woolfenden
- Markes International Ltd. 1000B Central Park, Western Avenue, Bridgend, CF31 3RT, UK
| |
Collapse
|
4
|
Kim PG, Lee A, Shin J, Song E, Koo Y, Mohamed DFMS, Choi S, Hong Y, Song S, Noh I, Kwon JH. Determination of terpene levels after the use of essential oil diffusers in vehicles and studio apartments using passive sampling. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 879:163071. [PMID: 36965723 DOI: 10.1016/j.scitotenv.2023.163071] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/07/2023] [Accepted: 03/22/2023] [Indexed: 05/17/2023]
Abstract
The exposure levels of selected terpenes (limonene, α- and β-pinenes, and γ-terpinene) emitted by essential oil diffusers in vehicles and studio apartments were assessed using a passive sampling method. A previously developed passive sampler composed of an expanded polytetrafluoroethylene membrane and adsorbent (ePTFE PS) was enlarged and made wearable. Before field deployment, the sampling performance of the modified ePTFE PS for selected terpenes was compared with that of active sampling in a lab-scale 5 m3 test chamber under constant exposure conditions, supporting that passive sampling provides reasonable estimates of the time-weighted exposure concentration. Fifty volunteers were recruited and asked to wear the ePTFE PS while using an essential oil diffuser inside their own vehicle while commuting and in their studio apartment while sleeping. Terpene levels without an essential oil diffuser were very low in vehicles and 47, 3.6, 1.6, and 0.62 μg m-3 for average concentrations of limonene, α- and β-pinenes, and γ-terpinene in studio apartments, respectively, close to those reported in previous studies. The indoor concentrations of all selected terpenes in vehicles and studio apartments were elevated by the use of essential oil diffusers, especially in vehicles. The average concentration of limonene in vehicles after the use of essential oil diffusers was 11 μg m-3, which was greater than that before use by a factor of 30. Therefore, cautious usage of essential oil diffusers indoors where the volume is limited, such as a vehicle, is needed to reduce exposure to terpenes.
Collapse
Affiliation(s)
- Pil-Gon Kim
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Arum Lee
- Department of Consumer Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Jaeho Shin
- Department of Consumer Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Eugene Song
- Department of Consumer Science, Chungbuk National University, Cheongju 28644, Republic of Korea
| | - Yerim Koo
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Dana Fahad M S Mohamed
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Soobin Choi
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea
| | - Yongseok Hong
- Department of Environmental Engineering, College of Science and Technology, Korea University Sejong Campus, Sejong City 30019, Republic of Korea
| | - Seokho Song
- Bio Division, Environmental Toxicity Center, Korea Conformity Laboratories, Incheon 21999, Republic of Korea
| | - Incheol Noh
- Environment Division, Chemical Analysis Center, Korea Conformity Laboratories, Seoul 08503, Republic of Korea
| | - Jung-Hwan Kwon
- Division of Environmental Science and Ecological Engineering, Korea University, 145 Anam-ro, Seongbuk-gu, Seoul 02841, Republic of Korea.
| |
Collapse
|
5
|
Lee YH, Wang CH, Hsu PH, Hsieh HC, Wang JL. A wide range of toxic VOCs measured by dual-sorbent passive sampling with validation by field online measurements. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2022; 314:120201. [PMID: 36210585 DOI: 10.1016/j.envpol.2022.120201] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2022] [Revised: 09/13/2022] [Accepted: 09/14/2022] [Indexed: 06/16/2023]
Abstract
This study modified a passive sampling technique similar to the US EPA Method 325 A/B method but extended to include more toxic volatile organic compounds (VOCs) under varied climate conditions to enhance field applicability. A mixing chamber was built to determine uptake rates (Us) for the target compounds. It was found that the Us of 27 air toxics previously reported in the literature agreed reasonably well with our findings within 18%, thus proving the chamber's integrity. To broaden the compound coverage, both Carbopack X and Carboxen 569 were studied for a suite of toxic VOCs to meet stringent quality control (QC) criteria of correlation coefficients (R-square), method detection limits (MDL), back diffusion (BD), storage stability, as well as a wide range of climate conditions in temperature and humidity. After excluding the species that failed to pass any of the QC criteria, Carbopack X was found to fit 50 air toxics, whereas Carboxen 569 held 37. After excluding the overlapped species, 61 toxic VOCs can be determined with robust Us for a broad range of climate conditions when the two sorbents are used in pairs. A one-week field measurement was conducted to compare with the online thermal desorption gas chromatography-mass spectrometry (TD-GC-MS) with hourly data resolution. The field passive sampling showed comparable results to the means of the online hourly measurements, despite the high variability of selected target compounds, such as toluene from 0.3 ppbv as the 5th percentile to the maximum of about 80 ppbv. Passive sampling clearly demonstrated the ability to smooth out concentration variability and thus the time-averaging strength of toxic VOCs, revealing its ideal role as an exposure monitor over time. The passive sampling method can be more desired than active sampling or online methods when the aim is simply the knowledge of prolonged time-averaged concentrations.
Collapse
Affiliation(s)
- Yu-Hsun Lee
- Department of Chemistry, National Central University, Taoyuan, 320, Taiwan
| | - Chieh-Heng Wang
- Center for Environmental Studies, National Central University, Taoyuan, 320, Taiwan
| | - Pei-Hsuan Hsu
- Department of Chemistry, National Central University, Taoyuan, 320, Taiwan
| | - Hsin-Cheng Hsieh
- Department of Chemistry, National Central University, Taoyuan, 320, Taiwan
| | - Jia-Lin Wang
- Department of Chemistry, National Central University, Taoyuan, 320, Taiwan.
| |
Collapse
|
6
|
Ninyà N, Vallecillos L, Marcé RM, Borrull F. Evaluation of air quality in indoor and outdoor environments: Impact of anti-COVID-19 measures. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 836:155611. [PMID: 35504390 PMCID: PMC9057935 DOI: 10.1016/j.scitotenv.2022.155611] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/19/2021] [Revised: 04/25/2022] [Accepted: 04/26/2022] [Indexed: 05/18/2023]
Abstract
This study monitors the presence of 88 volatile organic compounds (VOCs) and semi-volatile organic compounds (semi-VOCs) at the gas phase of seven indoor settings in a school in the city of Tarragona, Spain, and five outdoor locations around the city. The VOCs and semi-VOCs monitored were solvents (∑Solvents), aldehydes (∑Aldehydes), emerging organic compounds (∑EOCs), and other VOCs and semi-VOCs (∑Others). Passive sampling campaigns were performed using Carbopack X tubes followed by thermal desorption coupled to gas chromatography with mass spectrometry (TD-GC-MS). Overall, 70 of the target compounds included in the method were determined in the indoor air samples analysed, and 42 VOCs and semi-VOCs in the outdoor air samples. Our results showed that solvents were ubiquitous throughout the school at concentrations ranging from 272 μg m-3 to 423 μg m-3 and representing 68%-83% of total target compounds (∑Total). The values of ∑Total in 2021 were three times as high as those observed at the same indoor settings in 2019, with solvents experiencing the greatest increase. A plausible explanation for these observations is the implementation of anti-COVID-19 measures in the indoor settings, such as the intensification of cleaning activities and the use of hydroalcoholic gels as personal hygiene. The ∑Total values observed in the indoor settings evaluated were twenty times higher than those found outdoors. ∑Solvents were the most representative compounds found indoors (74% of the ∑Total). The concentrations of VOCs and semi-VOCs observed in the outdoors were strictly related to combustion processes from automobile traffic and industrial activities, with ∑Others contributing 58%, ∑Solvents 31%, and ∑Aldehydes 11% of the ∑Total. EOCs, on the other hand, were not detected in any outdoor sample.
Collapse
Affiliation(s)
- Nicole Ninyà
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel∙lí Domingo, 1, Tarragona 43007, Spain
| | - Laura Vallecillos
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel∙lí Domingo, 1, Tarragona 43007, Spain
| | - Rosa Maria Marcé
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel∙lí Domingo, 1, Tarragona 43007, Spain
| | - Francesc Borrull
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel∙lí Domingo, 1, Tarragona 43007, Spain.
| |
Collapse
|
7
|
Zhang Q, Liu S, Wang Z, Li R, Zhang L, Dong Z. Effects of a barium-based additive on gaseous and particulate emissions of a diesel engine. JOURNAL OF HAZARDOUS MATERIALS 2022; 427:128124. [PMID: 34973575 DOI: 10.1016/j.jhazmat.2021.128124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/13/2021] [Revised: 12/17/2021] [Accepted: 12/17/2021] [Indexed: 06/14/2023]
Abstract
The addition of barium-based additives is one of the main methods used to suppress smoke emissions in non-road diesel engines. Herein, a commercial barium-based additive was added to diesel fuel at the manufacturer's recommended concentration and used in a non-road four-cylinder supercharged diesel engine, without an after-treatment system, in bench experiments. Regulated emissions of the diesel engine were measured, volatile organic compounds (VOCs) and particulate matter (PM) were sampled. The carbonaceous fraction, water-soluble ions and inorganic elements in the PM were analyzed. Results indicated that the additive effectively reduced carbon monoxide (CO), hydrocarbon (HC) and smoke emissions from the engine. A 71% reduction in smoke was observed at the rated working condition, which was the maximum reduction of the three tested conditions. The additive produced a 36% reduction of VOCs at the rated working condition. The proportion of high carbon number hydrocarbons in the VOCs increased while the atmospheric reactivity of the VOCs decreased. The additive suppressed the concentration of organic carbon (OC) and elemental carbon (EC) emissions with a maximum reduction (40%) of total carbon achieved under the rated working condition. After the application of the additive, the concentration of water-soluble ions (Cl-, SO42-, NO3-, Na+, K+, Ca2+, NH4+) and elements (Fe, Mn, S, Ca, Ba) in the PM increased. A trend of increasing Barium content in the PM matched a similar trend of decreasing smoke.
Collapse
Affiliation(s)
- Qixia Zhang
- School of Automobile and Traffic Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Shuai Liu
- School of Automobile and Traffic Engineering, Jiangsu University, Zhenjiang 212013, China; Tsinghua University Suzhou Automotive Research Institute, Suzhou 215200, China.
| | - Zhong Wang
- School of Automobile and Traffic Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Ruina Li
- School of Automobile and Traffic Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Libin Zhang
- School of Automobile and Traffic Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Zheng Dong
- Jiangsu Zhenjiang Environmental Monitoring Center Station, Zhenjiang 212004, China
| |
Collapse
|
8
|
Chen WQ, Zhang XY. 1,3-Butadiene: a ubiquitous environmental mutagen and its associations with diseases. Genes Environ 2022; 44:3. [PMID: 35012685 PMCID: PMC8744311 DOI: 10.1186/s41021-021-00233-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Accepted: 12/27/2021] [Indexed: 01/09/2023] Open
Abstract
1,3-Butadiene (BD) is a petrochemical manufactured in high volumes. It is a human carcinogen and can induce lymphohematopoietic cancers, particularly leukemia, in occupationally-exposed workers. BD is an air pollutant with the major environmental sources being automobile exhaust and tobacco smoke. It is one of the major constituents and is considered the most carcinogenic compound in cigarette smoke. The BD concentrations in urban areas usually vary between 0.01 and 3.3 μg/m3 but can be significantly higher in some microenvironments. For BD exposure of the general population, microenvironments, particularly indoor microenvironments, are the primary determinant and environmental tobacco smoke is the main contributor. BD has high cancer risk and has been ranked the second or the third in the environmental pollutants monitored in most urban areas, with the cancer risks exceeding 10-5. Mutagenicity/carcinogenicity of BD is mediated by its genotoxic metabolites but the specific metabolite(s) responsible for the effects in humans have not been determined. BD can be bioactivated to yield three mutagenic epoxide metabolites by cytochrome P450 enzymes, or potentially be biotransformed into a mutagenic chlorohydrin by myeloperoxidase, a peroxidase almost specifically present in neutrophils and monocytes. Several urinary BD biomarkers have been developed, among which N-acetyl-S-(4-hydroxy-2-buten-1-yl)-L-cysteine is the most sensitive and is suitable for biomonitoring BD exposure in the general population. Exposure to BD has been associated with leukemia, cardiovascular disease, and possibly reproductive effects, and may be associated with several cancers, autism, and asthma in children. Collectively, BD is a ubiquitous pollutant that has been associated with a range of adverse health effects and diseases with children being a subpopulation with potentially greater susceptibility. Its adverse effects on human health may have been underestimated and more studies are needed.
Collapse
Affiliation(s)
- Wan-Qi Chen
- School of Public Health, Hongqiao International Institute of Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China
| | - Xin-Yu Zhang
- School of Public Health, Hongqiao International Institute of Medicine, Shanghai Jiao Tong University School of Medicine, Shanghai, 200025, China.
| |
Collapse
|
9
|
Miller DD, Bajracharya A, Dickinson GN, Durbin TA, McGarry JKP, Moser EP, Nuñez LA, Pukkila EJ, Scott PS, Sutton PJ, Johnston NAC. Diffusive uptake rates for passive air sampling: Application to volatile organic compound exposure during FIREX-AQ campaign. CHEMOSPHERE 2022; 287:131808. [PMID: 34461330 PMCID: PMC8612956 DOI: 10.1016/j.chemosphere.2021.131808] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2021] [Revised: 08/02/2021] [Accepted: 08/03/2021] [Indexed: 06/13/2023]
Abstract
Passive (diffusive) sampling using sorbents is an economical and versatile method of measuring pollutants in air, including volatile organic compounds (VOCs). Diffusive uptake rates (UTRs) are needed for each analyte to obtain average concentrations during a specific passive sampling time duration. Here, a simultaneous active/diffusive ambient air sampling technique on Tenax®TA was employed to measure 24-hours, 7, 14 and 28-days UTRs of up to 27 VOCs, including benzene, toluene, ethylbenzene, xylenes (BTEX), C6-C12 hydrocarbons, benzenes derivatives, tetrachloroethylene, pinenes and limonene. Samples were analyzed via thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) for desired analytes. Seven-day UTR values ranged from 0.17 to 0.59 mL/min and many compounds exhibited a linear relationship with UTR and time duration up to 14 or 28 days. This may be the most comprehensive UTR tabulation of VOCs on Tenax®TA for time periods of 24 hours -28 days available. These rates were applied to VOC data measured during the 2019 NASA/NOAA Fire Influence on Regional to Global Environments and Air Quality (FIREX-AQ) campaign, with goals to determine the chemical composition of western US wildfire smoke and to assess human exposure to air toxics. Summer 2019 exposure levels of BTEX at five Northwestern cities were low and the cancer risk due to benzene was assessed during FIREX-AQ to be background or 1 × 10-6. The UTRs derived here can be useful in applications of diffusive sampling, including estimation of sub-chronic to chronic human exposure risk of air toxics and wildfire smoke.
Collapse
Affiliation(s)
- Dylan D Miller
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Aakriti Bajracharya
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Gabrielle N Dickinson
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Timbre A Durbin
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - John K P McGarry
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Elijah P Moser
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Laurel A Nuñez
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Elias J Pukkila
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Phillip S Scott
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Parke J Sutton
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA
| | - Nancy A C Johnston
- Physical, Life, Movement and Sport Sciences Division, Lewis-Clark State College, 500 8th Avenue, Lewiston, ID, USA.
| |
Collapse
|
10
|
Kim PG, Kwon JH, Hong Y. Development of an expanded polytetrafluorethylene dosimeter for the passive sampling of volatile organic compounds in air. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 797:149026. [PMID: 34303233 DOI: 10.1016/j.scitotenv.2021.149026] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2021] [Revised: 06/26/2021] [Accepted: 07/09/2021] [Indexed: 06/13/2023]
Abstract
A passive sampler composed of a porous, hydrophobic, and gas-permeable expanded polytetrafluoroethylene (ePTFE) tube was developed to effectively concentrate volatile organic compounds (VOCs) in the air. The ePTFE dosimeter has larger sorbent mass normalized sampling rates (L h-1) compared with literature. This result suggests that ePTFE dosimeter can effectively detect low level VOCs in less contaminated air, including indoors. The air boundary layer thickness can be neglected when the mass accumulated in sorbent is converted to gas phase VOCs concentrations. The vapor pressure dependent desorption of VOCs from the sorbent was observed and modeling results suggested that this could lead to the underestimation of VOCs concentrations in air. However, the determination of the appropriate sampling time and the consideration of desorption could overcome the underestimation. A proton transfer reaction quadrupole mass spectrometer and passive samplers were deployed simultaneously in a chamber under fluctuating VOCs concentrations in air. The time-weighted average concentrations of ethylbenzene were 0.016, 0.015, and 0.017 g m-3 for 23, 46, and 69 min experimental period, respectively. The average concentration of the real-time analysis was 0.015 g m-3 for 69 min. The results show the ePTFE dosimeter can be used to estimate time weighted VOCs concentrations in air.
Collapse
Affiliation(s)
- Pil-Gon Kim
- Division of Environmental Science and Ecological Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Jung-Hwan Kwon
- Division of Environmental Science and Ecological Engineering, Korea University, Seoul 02841, Republic of Korea
| | - Yongseok Hong
- Department of Environmental Engineering, College of Science and Technology, Korea University Sejong Campus, Sejong City 30019, Republic of Korea.
| |
Collapse
|
11
|
Vallecillos L, Borrull A, Marcé RM, Borrull F. Presence of emerging organic contaminants and solvents in schools using passive sampling. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 764:142903. [PMID: 33757256 DOI: 10.1016/j.scitotenv.2020.142903] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/20/2020] [Revised: 09/28/2020] [Accepted: 10/02/2020] [Indexed: 05/06/2023]
Abstract
In this study, we report on the applicability of passive sampling with Carbopack X adsorbent tubes followed by thermal desorption gas-chromatography-mass spectrometry (TD-GC-MS) to monitor the concentrations of emerging organic contaminants (EOCs) and solvents in ten indoor environments in a conventional and a vocational training school. However, if passive sampling is to be used as a reliable sampling technique, a specific diffusive uptake rate is required for each target compound. Accordingly, the aim of the present study was twofold. The first was to determine the experimental diffusive uptake rates of the target EOCs and solvents in one of the sampling sites of the vocational training school using Carbopack X adsorbent tubes and active sampling as the reference technique. The results showed experimental diffusive uptake rates between 0.46 mL min-1 and 0.94 mL min-1 with RSD % below 5% for the 28 target compounds. The second was to apply the uptake rates obtained experimentally to determine EOCs and solvents in schools. The monitoring results showed that solvents were ubiquitous throughout the conventional school with a concentrations range between 51.93 μg m-3 and 164.6 μg m-3, while EOCs were detected to a lesser extent. Moreover, the concentrations of EOCs in the vocational training school were much higher than those in the conventional school with concentrations of up to 562.9 μg m-3 for solvents and 344.3 μg m-3 for acrylate polymer monomers. After actively sampling for seven days in each school, we concluded that the concentrations of EOCs and solvents found are mostly linked to cleaning products (conventional school) and the activities carried out in the classroom (vocational training school).
Collapse
Affiliation(s)
- Laura Vallecillos
- Eurecat, Centre Tecnològic de Catalunya, Water, Air and Soil Unit, Marcel·lí Domingo n 2, Tarragona 43007, Spain
| | - Anna Borrull
- Department of Biochemistry and Biotechnology, Universitat Rovira i Virgili, Sescelades Campus, Marcel∙lí Domingo n 1, Tarragona 43007, Spain
| | - Rosa Maria Marcé
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel∙lí Domingo n 1, Tarragona 43007, Spain
| | - Francesc Borrull
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Marcel∙lí Domingo n 1, Tarragona 43007, Spain.
| |
Collapse
|
12
|
Gonçalves AD, Martins TG, Cassella RJ. Passive sampling of toluene (and benzene) in indoor air using a semipermeable membrane device. ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY 2021; 208:111707. [PMID: 33396038 DOI: 10.1016/j.ecoenv.2020.111707] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2020] [Revised: 11/11/2020] [Accepted: 11/19/2020] [Indexed: 06/12/2023]
Abstract
The distribution and concentration of organic compounds in the environment have attracted great interest mainly due to their capability of bioaccumulation, dispersion, and danger to living organisms. Factors such as urbanization, population growth, and the emergence of new technologies contribute to the increase in pollutant emissions, especially volatile organic compounds (VOCs), such as benzene, toluene, ethylbenzene, and xylenes (BTEX). These compounds are emitted by several sources, becoming more common in work environments, influencing indoor air quality (IAQ), which can cause health damage, in addition to increasing the likelihood of cancer development. In this context, we developed a semipermeable membrane device (SPMD), consisting of low density polyethylene membrane (8 cm long × 3 cm wide), filled with 3 mL of acetonitrile, for passive sampling of toluene (and benzene) in gas phase. With this configuration, the SPMD needed 24 h exposure to the indoor air in order to achieve equilibrium. The target compounds were quantified in the acceptor phase by HPLC-DAD. The optimized SPMD was tested for the collection of toluene and benzene in six chemistry laboratories at Fluminense Federal University and in five nail salons in the city of Niterói, in the state of Rio de Janeiro, Brazil. The developed sampling method was able to identify the analytes in the indoor air of the studied environments, and was easy to operate, with no need to clean up the extracts, allowing their direct injection into the chromatographic system.
Collapse
Affiliation(s)
- Aline D Gonçalves
- Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Centro, Niterói/RJ 24020-141, Brazil; Departamento de Química Analítica, Universidade Federal do Rio de Janeiro, Rio de Janeiro/RJ 21941-909, Brazil
| | - Tayene G Martins
- Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Centro, Niterói/RJ 24020-141, Brazil
| | - Ricardo J Cassella
- Departamento de Química Analítica, Universidade Federal Fluminense, Outeiro de São João Batista s/n, Centro, Niterói/RJ 24020-141, Brazil.
| |
Collapse
|
13
|
Vallecillos L, Borrull A, Marcé RM, Borrull F. Passive sampling to control air quality in schools: Uptake rate determination and application. INDOOR AIR 2020; 30:1005-1017. [PMID: 32339338 DOI: 10.1111/ina.12684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2020] [Revised: 03/30/2020] [Accepted: 04/22/2020] [Indexed: 05/06/2023]
Abstract
In this paper, we provide a detailed description of the application of passive sampling with Carbopack X tubes followed by thermal desorption-gas chromatography-mass spectrometry (TD-GC-MS) to determine the concentrations of volatile organic compounds (VOCs) in different school environments. The main objective of the study was to monitor VOCs in seven indoor and three outdoor environments at a school in Tarragona, Spain. However, in order to obtain more accurate information, it was necessary to determine the experimental diffusive uptake rates of the target VOCs in indoor settings through parallel passive and active sampling in one classroom. The results showed experimental diffusive uptake rates in the range of 0.38 mL min-1 and 0.95 mL min-1 with RSD % below 5% for up to 44 VOCs. The monitoring results showed that ethanol (23.84-83.16 µg m-3 ) and isopropyl alcohol (5.42-25.92 µg m-3 ) were the most common compounds found in indoor environments, with cleaning products as the main emission source. The VOCs i-pentane and n-pentane were found at the highest concentrations in the three sampling sites set in the school's playground, and their concentrations were strictly related to combustion processes from automobile traffic.
Collapse
Affiliation(s)
- Laura Vallecillos
- Centre Tecnològic de Catalunya, Water, Air and Soil Unit, Eurecat, Tarragona, Spain
| | - Anna Borrull
- Department of Biochemistry and Biotechnology, Universitat Rovira i Virgili, Sescelades Campus, Tarragona, Spain
| | - Rosa Maria Marcé
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Tarragona, Spain
| | - Francesc Borrull
- Department of Analytical Chemistry and Organic Chemistry, Universitat Rovira i Virgili, Sescelades Campus, Tarragona, Spain
| |
Collapse
|
14
|
Yavarinasab A, Janfaza S, Tasnim N, Tahmooressi H, Dalili A, Hoorfar M. Graphene/poly (methyl methacrylate) electrochemical impedance-transduced chemiresistor for detection of volatile organic compounds in aqueous medium. Anal Chim Acta 2020; 1109:27-36. [DOI: 10.1016/j.aca.2020.02.065] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2020] [Revised: 02/26/2020] [Accepted: 02/29/2020] [Indexed: 12/14/2022]
|
15
|
Gallego E, Folch J, Teixidor P, Roca FJ, Perales JF. Outdoor air monitoring: Performance evaluation of a gas sensor to assess episodic nuisance/odorous events using active multi-sorbent bed tube sampling coupled to TD-GC/MS analysis. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 694:133752. [PMID: 31401501 DOI: 10.1016/j.scitotenv.2019.133752] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/16/2019] [Revised: 07/23/2019] [Accepted: 08/02/2019] [Indexed: 06/10/2023]
Abstract
In order to evaluate the performance of a commercially available metal oxide semiconductor gas sensor (TGS 2602, Figaro Engineering Inc.) for activating a monitoring system when a nuisance/odorous pollution episode of volatile organic compounds (VOCs) occur, a widely used active sampling methodology based on multi-sorbent bed tubes (Carbotrap, Carbopack X and Carboxen 569) and analysis through automatic thermal desorption-gas chromatography/mass spectrometry was used. Daily 24 h samples of multi-sorbent bed tubes were taken over a period of 14 days using an air collector pump sampler specially designed in the LCMA-UPC laboratory. Simultaneously, daily episodic samples were taken according to the activation of another LCMA-UPC sampler by the metal oxide semiconductor gas sensor. Sampling was done throughout January-February 2019 at El Morell (Tarragona, Spain), near the petrochemical area. All episode samples present higher concentrations of VOCs than 24 h samples, with an average ratio of 3.5 times for Total VOCs. VOC familial distributions present very similar values in 24 h and episode samples (r2 = 0.7466), correlating significatively (F-Snedecor, p < 0.05). A higher level of VOCs in the atmosphere in general, not derived from a specific compound or a VOC/s family/ies, seems to be the trigger of the activation of the sampler by the sensor. On the other hand, no significant correlations are observed between alcohols concentrations and relative humidity (F-Snedecor, p < 0.05). Additionally, Total VOCs concentrations in episode samples are in agreement with higher percentages of NE-SSE wind directions, coming from the petrochemical complex. Hence, these aspects validate the use of the evaluated sensor for its application for the activation of samplers in air quality evaluations when episodic events occur, an interesting and innovative technique. Thus, this study is an important contribution to the understanding of the performance of gas sensors and proposes an expansion of their field of use.
Collapse
Affiliation(s)
- Eva Gallego
- Laboratori del Centre de Medi Ambient, Escola Tècnica Superior d'Enginyeria Industrial de Barcelona (ETSEIB), Universitat Politècnica de Catalunya (LCMA-UPC), Avda. Diagonal, 647, E 08028 Barcelona, Spain.
| | - Jaume Folch
- Laboratori del Centre de Medi Ambient, Escola Tècnica Superior d'Enginyeria Industrial de Barcelona (ETSEIB), Universitat Politècnica de Catalunya (LCMA-UPC), Avda. Diagonal, 647, E 08028 Barcelona, Spain
| | - Pilar Teixidor
- Centres Científics i Tecnològics, Universitat de Barcelona (CCiTUB), Lluís Solé Sabarís 1-3, E 08034 Barcelona, Spain.
| | - Francisco Javier Roca
- Laboratori del Centre de Medi Ambient, Escola Tècnica Superior d'Enginyeria Industrial de Barcelona (ETSEIB), Universitat Politècnica de Catalunya (LCMA-UPC), Avda. Diagonal, 647, E 08028 Barcelona, Spain
| | - José Francisco Perales
- Laboratori del Centre de Medi Ambient, Escola Tècnica Superior d'Enginyeria Industrial de Barcelona (ETSEIB), Universitat Politècnica de Catalunya (LCMA-UPC), Avda. Diagonal, 647, E 08028 Barcelona, Spain
| |
Collapse
|