1
|
Perras FA, Pruski M. Linear-scaling ab initio simulations of spin diffusion in rotating solids. J Chem Phys 2019; 151:034110. [PMID: 31325939 DOI: 10.1063/1.5099146] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023] Open
Abstract
We investigated the utility of locally restricting the basis sets involved in low-order correlations in Liouville space (LCL) calculations of spin diffusion. Using well-known classical models of spin diffusion, we describe a rationale for selecting the optimal basis set for such calculations. We then show that the use of these locally restricted basis sets provides the same computational accuracy as the full LCL set while reducing the computational time by several orders of magnitude. Speeding up the calculations also enables us to use higher maximum spin orders and increase the computational accuracy. Furthermore, unlike exact and full LCL calculations, locally restricted LCL calculations scale linearly with the system size and should thus enable the ab initio study of spin diffusion in spin systems containing several thousand spins.
Collapse
|
2
|
Li Y, Trébosc J, Hu B, Shen M, Amoureux JP, Lafon O. Indirect detection of broad spectra in solid-state NMR using interleaved DANTE trains. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 294:101-114. [PMID: 30032034 DOI: 10.1016/j.jmr.2018.07.005] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/16/2018] [Revised: 07/03/2018] [Accepted: 07/07/2018] [Indexed: 06/08/2023]
Abstract
We analyze the performances and the optimization of 1H-{I} HMQC experiments using basic and interleaved DANTE schemes for the indirect detection of nuclei I = 1/2 or 1 exhibiting wide lines dominated by chemical shift anisotropy (CSA) or quadrupole interaction, respectively. These sequences are first described using average Hamiltonian theory. Then, we analyze using numerical simulations (i) the optimal lengths of the DANTE train and the individual pulses, (ii) the robustness of these experiments to offset, and (iii) the optimal choice of the defocusing and refocusing times for both 1H-{I} J- and D-HMQC sequences for 195Pt (I = 1/2) and 14N (I = 1) nuclei subject to large CSA and quadrupole interaction, respectively. These simulations are compared to 1H-{14N} D-HMQC experiments on γ-glycine and L-histidine.HCl at B0 = 18.8 T and MAS frequency of 62.5 kHz. The present study shows that (i) the optimal defocusing and refocusing times do not depend on the chosen DANTE scheme, (ii) the DANTE trains must be applied with the highest rf-field compatible with the probe specifications and the stability of the sample, (iii) the excitation bandwidth along the indirect dimension of HMQC sequence using DANTE trains is inversely proportional to their length, (iv) interleaved DANTE trains increase the excitation bandwidth of these sequences, and (v) dephasing under residual 1H-1H and 1H-I dipolar couplings, as well as 14N second-order quadrupole interaction, during the length of the DANTE scheme attenuate the transfer efficiency.
Collapse
Affiliation(s)
- Yixuan Li
- Univ. Lille, CNRS, UMR 8181-UCCS, Unité de Catalyse et de Chimie du Solide, F-59000 Lille, France; Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Materials Science, East China Normal University, Shanghai 200062, China
| | - Julien Trébosc
- Univ. Lille, CNRS, UMR 8181-UCCS, Unité de Catalyse et de Chimie du Solide, F-59000 Lille, France
| | - Bingwen Hu
- Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Materials Science, East China Normal University, Shanghai 200062, China
| | - Ming Shen
- Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Materials Science, East China Normal University, Shanghai 200062, China
| | - Jean-Paul Amoureux
- Univ. Lille, CNRS, UMR 8181-UCCS, Unité de Catalyse et de Chimie du Solide, F-59000 Lille, France; Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Materials Science, East China Normal University, Shanghai 200062, China; Bruker France, 34 rue de l'Industrie, F-67166 Wissembourg, France.
| | - Olivier Lafon
- Univ. Lille, CNRS, UMR 8181-UCCS, Unité de Catalyse et de Chimie du Solide, F-59000 Lille, France; Institut Universitaire de France, 1, rue Descartes, 75231 Paris, France.
| |
Collapse
|
3
|
Gan Z, Hung I, Nishiyama Y, Amoureux JP, Lafon O, Nagashima H, Trébosc J, Hu B. 14N overtone nuclear magnetic resonance of rotating solids. J Chem Phys 2018; 149:064201. [PMID: 30111134 PMCID: PMC8808743 DOI: 10.1063/1.5044653] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2018] [Accepted: 07/17/2018] [Indexed: 11/14/2022] Open
Abstract
By irradiating and observing at twice the 14N Larmor frequency, overtone (OT) nuclear magnetic resonance (NMR) is capable of obtaining 14NOT spectra without first-order quadrupolar broadening. Direct excitation and detection of the usually "forbidden" double-quantum transition is mediated by the perturbation from the large quadrupole interaction to the spin states quantized by the Zeeman interaction. A recent study [L. A. O'Dell and C. I. Ratcliffe, Chem. Phys. Lett. 514, 168 (2011)] has shown that 14NOT NMR under magic-angle spinning (MAS) can yield high-resolution spectra with typical second-order quadrupolar line shapes allowing the measurement of 14N chemical shift and quadrupolar coupling parameters. This article has also shown that under MAS the main 14NOT peak is shifted by twice the sample spinning frequency with respect to its static position. We present the theory of 14NOT NMR of static or rotating samples and the physical picture of the intriguing spinning-induced shift in the second case. We use perturbation theory for the case of static samples and Floquet theory for rotating samples. In both cases, the results can be described by a so-called OT parameter that scales down the 14NOT radio-frequency (rf) excitation and signal detection. This OT parameter shows that the components of the rf field, which are transverse and longitudinal with respect to the magnetic field, are both effective for 14NOTrf excitation and signal detection. In the case of MAS at angular frequency ωr , the superposition of the excitation and detection components in the OT parameter makes either the +2ωr or -2ωr term the dominant 14NOT signal, depending on the sense of sample spinning with respect to the magnetic field. This leads to an apparent 14NOT signal shifted at twice the spinning frequency. The features of 14NOT NMR spectra for both static and rotating samples are illustrated with simulations. The spinning induced shift and its dependence on the spinning direction are confirmed experimentally by reversing the spinning direction and the field of the 36 T series-connected hybrid magnet at the US National High Magnetic Field Laboratory.
Collapse
Affiliation(s)
- Zhehong Gan
- Center of Interdisciplinary Magnetic Resonance, National High Magnetic Field Laboratory, 1800 East Paul Dirac Drive, Tallahassee, Florida 32310, USA
| | - Ivan Hung
- Center of Interdisciplinary Magnetic Resonance, National High Magnetic Field Laboratory, 1800 East Paul Dirac Drive, Tallahassee, Florida 32310, USA
| | | | | | | | - Hiroki Nagashima
- Univ. Lille, CNRS UMR 8181, UCCS Unit of Catalysis and Chemistry of Solids, F-59000 Lille, France
| | - Julien Trébosc
- Univ. Lille, CNRS UMR 8181, UCCS Unit of Catalysis and Chemistry of Solids, F-59000 Lille, France
| | - Bingwen Hu
- Shanghai Key Laboratory of Magnetic Resonance, School of Physics and Materials Science, East China Normal University, Shanghai 200062, China
| |
Collapse
|
4
|
Duong NT, Kuprov I, Nishiyama Y. Indirect detection of 10B (I = 3) overtone NMR at very fast magic angle spinning. JOURNAL OF MAGNETIC RESONANCE (SAN DIEGO, CALIF. : 1997) 2018; 291:27-31. [PMID: 29677601 DOI: 10.1016/j.jmr.2018.04.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/19/2018] [Revised: 04/05/2018] [Accepted: 04/09/2018] [Indexed: 06/08/2023]
Abstract
The application of overtone nuclear magnetic resonance (OT NMR) to symmetric spin transitions of integer quadrupolar nuclei is of considerable interest since this transition is immune to the first-order quadrupolar interaction, thus resulting in narrow NMR lines. Owing to its roles in nature and its high natural abundance, 14N (I = 1) OT NMR has been explored, in which the indirect and/or direct acquisitions of 14N OT were experimentally demonstrated. However, other than 14N nucleus, no OT NMR observation of other integer quadrupolar nuclei has been reported in the literature. In this work, we extend the application of OT NMR to another integer quadrupolar nucleus, namely 10B (I = 3). However, this is not straightforward owing to the unfavorable characteristics of 10B isotope. Here, for the first time, we present the selective acquisition of 10B central (-1 ↔ +1) OT NMR via detection of 1H nuclei on perborate monohydrate sample. Numerical calculations are in a good agreement with the experimental results. Both show that the optimal sensitivity is achieved when the carrier frequency is applied at the second OT spinning sideband, i.e. an offset of twice of the spinning frequency from the center band.
Collapse
Affiliation(s)
- Nghia Tuan Duong
- RIKEN CLST-JEOL Collaboration Center, RIKEN, Yokohama, Kanagawa 230-0045, Japan
| | - Ilya Kuprov
- School of Chemistry, University of Southampton, Highfield Campus, Southampton SO17 1BJ, UK
| | - Yusuke Nishiyama
- RIKEN CLST-JEOL Collaboration Center, RIKEN, Yokohama, Kanagawa 230-0045, Japan; JEOL RESONANCE Inc., Musashino, Akishima, Tokyo 196-8558, Japan.
| |
Collapse
|