1
|
Isabella Cestaro B, Cavalcanti Machado K, Batista M, José Gonçalves da Silva B. Hollow-fiber liquid phase microextraction for determination of fluoxetine in human serum by nano-liquid chromatography coupled to high resolution mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1234:124018. [PMID: 38286102 DOI: 10.1016/j.jchromb.2024.124018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 01/03/2024] [Accepted: 01/15/2024] [Indexed: 01/31/2024]
Abstract
Therapeutic drug monitoring (TDM) is a personalized care tool based on the determination of a target drug concentration in human serum. An antidepressant drug of interest for such investigations is fluoxetine (FXT), due to a severe impact of genetic polymorphisms on its metabolism. A bioanalytical method employed for TDM purposes must exhibit satisfactory selectivity and detectability, which becomes more difficult due to highly complex biological matrices. In this study, a highly selective bioanalytical method for the determination of FXT in human serum is proposed, which provides excellent clean-up efficiency based on a low cost hollow fiber liquid-phase microextraction (HF-LPME) sample preparation step and nano-liquid chromatography coupled to high-resolution mass spectrometry (nano-LC-HRMS). HF-LPME was performed using a two-phase "U" configuration, with 6 cm fiber, 20 µL of 1-octanol acting as supported liquid membrane, and ammonium hydroxide (pH 10) as the donor phase with NaCl (10 % m/v) and methanol (5 % v/v) as additives, requiring only 250 µL of the sample. The procedure was conducted for 30 min under a 750 rpm stirring rate. Gradient elution was carried out employing an acetonitrile-water as mobile phase, the composition of 30:70 to 100:00 (v/v) for 15 min, using formic acid 0.1 % (v/v) as an additive. MS1 was acquired in an Orbitrap mass analyzer, while MS2 was acquired in a linear trap quadrupole. Satisfactory linearity (Pearson's r = 0.99709) was obtained for a concentration range of 0.02 to 2.5 µg mL-1, which is compatible with the therapeutic and toxic range for FXT. The developed method presents adequate precision (1.61 to 7.45 %) and accuracy (95 to 114 %) and allows the dilution of high concentration samples in a 1:4 ratio (v/v), enabling its application for forensic serum samples. To our knowledge, this is the first study reporting a method based on HF-LPME and nano-LC-HRMS with any analytical purpose, especially with a TDM focus.
Collapse
Affiliation(s)
| | | | - Michel Batista
- Mass Spectrometry Facility RPT02H, Carlos Chagas Institute, Fiocruz, Curitiba 81350-010, Brazil
| | | |
Collapse
|
2
|
Olędzka I, Plenis A, Kowalski P, Bączek T, Roszkowska A. Analytical aspects of sample handling during the quantification of selective serotonin reuptake inhibitors in clinical applications. Trends Analyt Chem 2023. [DOI: 10.1016/j.trac.2023.117026] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/15/2023]
|
3
|
Roszkowska A, Plenis A, Kowalski P, Bączek T, Olędzka I. Recent advancements in techniques for analyzing modern, atypical antidepressants in complex biological matrices and their application in biomedical studies. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116609] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
4
|
Chai Y, Liu Z, Du Y, Wang L, Lu J, Zhang Q, Han W, Wang T, Yu Y, Sun L, Ou L. Hydroxyapatite reinforced inorganic-organic hybrid nanocomposite as high-performance adsorbents for bilirubin removal in vitro and in pig models. Bioact Mater 2021; 6:4772-4785. [PMID: 34095628 PMCID: PMC8144535 DOI: 10.1016/j.bioactmat.2021.05.017] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 04/15/2021] [Accepted: 05/10/2021] [Indexed: 12/20/2022] Open
Abstract
Highly efficient removal of bilirubin from whole blood directly by hemoperfusion for liver failure therapy remains a challenge in the clinical field due to the low adsorption capacity, poor mechanical strength and low biocompatibility of adsorbents. In this work, a new class of nanocomposite adsorbents was constructed through an inorganic-organic co-crosslinked nanocomposite network between vinyltriethoxysilane (VTES)-functionalized hydroxyapatite nanoparticles (V-Hap) and non-ionic styrene-divinylbenzene (PS-DVB) resins (PS-DVB/V-Hap) using suspension polymerization. Notably, our adsorbent demonstrated substantially improved mechanical performance compared to the pure polymer, with the hardness and modulus increasing by nearly 3 and 2.5 times, respectively. Moreover, due to the development of a mesoporous structure, the prepared PS-DVB/V-Hap3 exhibited an ideal adsorption capacity of 40.27 mg g-1. More importantly, the obtained adsorbent beads showed outstanding blood compatibility and biocompatibility. Furthermore, in vivo extracorporeal hemoperfusion verified the efficacy and biosafety of the adsorbent for directly removing bilirubin from whole blood in pig models, and this material could potentially prevent liver damage and improve clinical outcomes. Taken together, the results suggest that PS-DVB/V-Hap3 beads can be used in commercial adsorption columns to threat hyperbilirubinemia patients through hemoperfusion, thus replacing the existing techniques where plasma separation is initially required.
Collapse
Affiliation(s)
- Yamin Chai
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Zhuang Liu
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Yunzheng Du
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Lichun Wang
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Jinyan Lu
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Qian Zhang
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Wenyan Han
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Tingting Wang
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Yameng Yu
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| | - Lisha Sun
- General Hospital, Tianjin Medical University, Tianjin, 300052, China
| | - Lailiang Ou
- Key Laboratory of Bioactive Materials, Ministry of Education, College of Life Sciences, Nankai University, Tianjin, 300071, China
| |
Collapse
|
5
|
Langford JB, Lurie IS. Use of micro, capillary, and nano liquid chromatography for forensic analysis. J Sep Sci 2021; 45:38-50. [PMID: 34626162 DOI: 10.1002/jssc.202100631] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2021] [Revised: 09/28/2021] [Accepted: 09/29/2021] [Indexed: 01/03/2023]
Abstract
The use of micro, capillary, and nano liquid chromatography systems for forensic analysis has excellent potential. In a field where sample size is often limited, several studies have presented the viability of capillary columns with microflow and nanoflow, and when using mass spectrometric analysis limits of detection can be improved. Reduction in flow rates result in significant reduction in operating costs. Recent advances in miniaturized liquid chromatography systems also aim at in-laboratory and on-site detection, which have already been applied to forensic drug cases. This critical review will discuss the advantages, disadvantages, and applicability of microflow and nano liquid chromatography. In this regard, included in this article is a discussion of some promising areas not yet applied to forensic research.
Collapse
Affiliation(s)
- Joel B Langford
- Department of Forensic Science, The George Washington University, Washington, DC, 20007, USA
| | - Ira S Lurie
- Department of Forensic Science, The George Washington University, Washington, DC, 20007, USA
| |
Collapse
|
6
|
Zheng M, Zhang C, Wang L, Wang K, Kang W, Lian K, Li H. Determination of nine mental drugs in human plasma using solid-phase supported liquid-liquid extraction and HPLC-MS/MS. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105647] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
|
9
|
Sun T, Ali MM, Wang D, Du Z. On-site rapid screening of benzodiazepines in dietary supplements using pipette-tip micro-solid phase extraction coupled to ion mobility spectrometry. J Chromatogr A 2020; 1610:460547. [DOI: 10.1016/j.chroma.2019.460547] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 09/13/2019] [Accepted: 09/14/2019] [Indexed: 12/20/2022]
|