1
|
Vishwakarma P, Nigam P, Gupta T. Optimization of protocol for analysis of dicarboxylic acids in ambient aerosol samples using GC-MS: method comparison and application. ENVIRONMENTAL MONITORING AND ASSESSMENT 2025; 197:141. [PMID: 39777579 DOI: 10.1007/s10661-024-13539-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2024] [Accepted: 12/09/2024] [Indexed: 01/11/2025]
Abstract
Dicarboxylic acids (DCAs), with their deliquescence and hygroscopic nature, can function as cloud condensation nuclei (CCN) and ice nuclei (IN), affecting rainfall patterns. DCA analysis can serve as organic molecular markers for anthropogenic and biogenic sources. Very few studies deal with the optimization of the protocol for qualitative and quantitative analysis of DCAs using gas chromatography-mass spectrometry (GC-MS). In this study, we have optimized the extraction of DCAs from aerosol samples by employing several organic solvents with differing relative polarities. Extraction efficiencies of organic solvents were evaluated at different temperatures and pressures using the advanced energized dispersive extractor. The optimized outcomes demonstrate that extraction using methanol at 105 °C for 5 min resulted in high efficiencies, achieving over 80% recovery for all targeted C3-C10 dicarboxylic acids (DCAs). N,O-bis-(trimethylsilyl) trifluoroacetamide (BSTFA) with 1% trimethylchlorosilane (TMCS) was chosen as the derivatizing reagent, and reaction conditions were optimized to give maximum conversions. The derivatization process, conducted with 30 µL of BSTFA + 1% TMCS in a 200 µL reaction mixture at 70 °C for 90 min, yielded effective and reliable results for subsequent analysis. Separation of compounds was done on the HP-5 column with Helium as the carrier gas. Protocol was finalized by selecting the operating parameters in SIM mode that reduce the total run time while maintaining a clear resolution of peaks.
Collapse
Affiliation(s)
- Pratibha Vishwakarma
- Department of Civil Engineering, APTL, Centre for Environmental Science and Engineering (CESE), IIT Kanpur, Kanpur, 208016, UP, India.
| | - Poonam Nigam
- Department of Civil Engineering, APTL, Centre for Environmental Science and Engineering (CESE), IIT Kanpur, Kanpur, 208016, UP, India
| | - Tarun Gupta
- Department of Civil Engineering, APTL, Centre for Environmental Science and Engineering (CESE), IIT Kanpur, Kanpur, 208016, UP, India
| |
Collapse
|
2
|
Fei J, Sha Q, Zhu W, Liu S, Hu Z, Du W, Liu X. Synthesis of 2-methyl-6-methoxy-4-quinolinecarboxylic acid N-hydroxysuccinimide ester (MMQC-OSu) for streamlined and effective HPLC-based fluorescence detection of aliphatic amines in environmental samples. J Chromatogr B Analyt Technol Biomed Life Sci 2024; 1248:124348. [PMID: 39509966 DOI: 10.1016/j.jchromb.2024.124348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2024] [Revised: 10/22/2024] [Accepted: 10/24/2024] [Indexed: 11/15/2024]
Abstract
Aliphatic amines are widely distributed in the environment and food sources, posing potential health risks through skin and mucosal irritation. Consequently, their quantitative detection is crucial for assessing environmental health. Despite high reactivity and fluorescence properties of succinimidyl ester-based derivatization reagents, their application in the aliphatic amines detection is hampered by challenges such as limited detection sensitivity and fluorescence interference. We established an innovative synthetic approach to produce a series of succinimidyl esters with the desirable substituents. This advancement enabled the creation of efficient and highly sensitive reagents for the detection of aliphatic amines. Among them, 2-methyl-6-methoxy-4-quinolinecarboxylic acid N-hydroxysuccinimide ester (MMQC-OSu) exhibited the best detection performance. MMQC-OSu reacted with aliphatic amines at 40 °C in pH 8.0 buffer for 20 min, which was subsequently separated in a C18 chromatographic column with the fluorescence detection wavelength of 336/432 nm. This detection approach featured a rapid and mild reaction process, minimal interference from corresponding hydrolysis products, and impressive sensitivity (0.05 nM). These characteristics indicate that MMQC-OSu significantly surpassing commercial aliphatic amines detection reagents. Finally, the detection strategy of MMQC-OSu was successfully applied in environmental sample analysis, with recovery rate of 93 %-108 % and RSDs between 1.4 % and 6.5 %.
Collapse
Affiliation(s)
- Jian Fei
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Qiuyue Sha
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Wenjie Zhu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Si Liu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China; Department of Epidemiology and Health Statistics, School of Public Health, Fujian Medical University, Fuzhou 350122, China
| | - Zhaoyu Hu
- The Key Laboratory for Biomedical Photonics of MOE at Wuhan National Laboratory for Optoelectronics - Hubei Bioinformatics & Molecular Imaging Key Laboratory, Systems Biology Theme, Department of Biomedical Engineering, College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Wei Du
- College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.
| | - Xin Liu
- College of Life Science and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.
| |
Collapse
|
3
|
Bodur SE, Bodur S, Ayyıldız MF, Günkara ÖT, Dikmen Y, Doru ES, Bakırdere S. Determination of capsaicin at trace levels in different food, biological and environmental samples by quadruple isotope dilution-gas chromatography mass spectrometry after its preconcentration. J Chromatogr A 2024; 1731:465147. [PMID: 39038417 DOI: 10.1016/j.chroma.2024.465147] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Revised: 07/01/2024] [Accepted: 07/04/2024] [Indexed: 07/24/2024]
Abstract
Despite the therapeutic properties of capsaicin for some diseases, it shows some side effects for human health. The goal of this study was to develop a precise and accurate analytical strategy for the trace determination of capsaicin in different food, biological and environmental samples including pepper, saliva and wastewater by gas chromatography-mass spectrometry (GC-MS) after spraying-based fine droplet formation-liquid phase microextraction (SFDF-LPME) and quadruple isotope dilution (ID4) method. Acetic anhydride was used as derivatizing agent, and the extraction method was used to enrich the analyte derivative to reach low detection limits. Under the optimum conditions, limit of detection (LOD) and limit of quantitation (LOQ) were determined to be 0.33 and 1.10 µg/kg, respectively. Percent recoveries calculated for SFDF-LPME-GC-MS method ranged between 84.1 and 131.7 %. After the application of ID4-SFDF-LPME-GC-MS method, percent recoveries were obtained in the range of 94.9 and 104.0 % (%RSD ≤ 2.8) for the selected samples. It is obvious that the isotope dilution-based method provided high accurate and precise results due to the elimination of errors during the derivatization, extraction and measurement steps.
Collapse
Affiliation(s)
- Sezin Erarpat Bodur
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye
| | - Süleyman Bodur
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye; İstinye University, Faculty of Pharmacy, Department of Analytical Chemistry, 34010 İstanbul, Türkiye; İstinye University, Scientific and Technological Research Application and Research Center, 34010 İstanbul, Türkiye
| | - Merve Fırat Ayyıldız
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye; Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Türkiye
| | - Ömer Tahir Günkara
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye
| | - Yaren Dikmen
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye
| | - Esra Sultan Doru
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye; Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Türkiye
| | - Sezgin Bakırdere
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye; Turkish Academy of Sciences (TÜBA), Vedat Dalokay Street, No: 112, 06670, Çankaya, 06670, Ankara, Türkiye.
| |
Collapse
|
4
|
Cestaro BI, Nagata N, da Silva BJG. Evaluation of polypropylene microporous membranes as extraction devices for determination of carcinogenic aromatic amines in smoker urine by GC-MS/MS. J Chromatogr A 2024; 1729:465030. [PMID: 38838449 DOI: 10.1016/j.chroma.2024.465030] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2023] [Revised: 05/14/2024] [Accepted: 05/25/2024] [Indexed: 06/07/2024]
Abstract
Exposure to tobacco smoke is highly correlated to the incidence of different types of cancer due to various carcinogenic compounds present in such smoke. Aromatic amines, such as 1-naphthylamine (1-NA) and 2-naphthylamine (2-NA), are produced in tobacco burning and are linked to bladder cancer. Miniaturized solid phase extraction techniques, such as microporous membrane solid phase extraction (MMSPE), have shown potential for the extraction of aromatic compounds. In this study, a bioanalytical method for the determination of 1-NA and 2-NA in human urine was developed using polypropylene microporous membranes as a sorptive phase for MMSPE. Urine samples were hydrolyzed with HCl for 1 h at 80 °C, after which pH was adjusted to 10. Ultrasound-assisted MMSPE procedure was optimized by factorial design as follows. To each sample, 750 µL of methanol was added, and ultrasound-assisted MMSPE was conducted for 1 h with four devices containing seven 2 mm polypropylene membrane segments. After extraction, the segments were transferred to 400 µL of hexane, and desorption was conducted for 30 min. Extracts were submitted to a simple and fast microwave-assisted derivatization procedure, by the addition of 10 µL of PFPA and heating at 480 W for 3 min, followed by clean-up with phosphate buffer pH 8.0 and GC-MS/MS analysis. Adequate linearity was obtained for both analytes in a range from 25 to 500 µg L-1, while the multiple reaction monitoring approach provided satisfactory selectivity and specificity. Intra-day (n = 6) and inter-day (n = 5) precision and accuracy were satisfactory, below 15 % and between 85 and 115 %, respectively. Recovery rates found were 91.9 and 58.4 % for 1-NA and 2-NA, respectively, with adequate precision. 1-NA was found in first-hand smokers' urine samples in a concentration range from 20.98 to 89.09 µg in 24 h, while it could be detected in second-hand smoker's urine samples, and 2-NA detected in all first and second-hand smokers' urine samples. The proposed method expands the applicability of low cost MMSPE devices to aromatic amines and biological fluids.
Collapse
Affiliation(s)
- Beatriz Isabella Cestaro
- Chemistry Department, Universidade Federal do Paraná, Av. Cel. Francisco H. Dos Santos, 100, Jardim das Américas, Curitiba, PR 81531-980, Brazil.
| | - Noemi Nagata
- Chemistry Department, Universidade Federal do Paraná, Av. Cel. Francisco H. Dos Santos, 100, Jardim das Américas, Curitiba, PR 81531-980, Brazil
| | - Bruno José Gonçalves da Silva
- Chemistry Department, Universidade Federal do Paraná, Av. Cel. Francisco H. Dos Santos, 100, Jardim das Américas, Curitiba, PR 81531-980, Brazil
| |
Collapse
|
5
|
Liu Y, Hou X, Li X, Liu J, Jiang G. Simultaneous determination of 19 bromophenols by gas chromatography-mass spectrometry (GC-MS) after derivatization. Talanta 2024; 274:126015. [PMID: 38581850 DOI: 10.1016/j.talanta.2024.126015] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 03/26/2024] [Accepted: 03/29/2024] [Indexed: 04/08/2024]
Abstract
Bromophenols (BPs) are a class of ubiquitous emerging halogenated pollutants. Their 19 congeners are problematically separated and detected. This work described the separation and detection of 19 BP congeners by gas chromatography-mass spectrometry (GC-MS). Investigations into the derivatization of bromophenols were carried out using two silylation reagents (N,O-bis(trimethylsilyl)trifluoroacetamide and N-methyl-N-(trimethylsily)trifluoroacetamide), two alkylation reagents (methyl iodide and trimethylsilyldiazomethane) and acetic anhydride prior to GC-MS analysis. Optimal chromatographic separation, sensitivity, and linearity were achieved after BP derivatization using acetic anhydride, featuring the equipment detection limits of 0.39-1.26 pg and correlation coefficients of 0.9948-0.9999 (linear range: 0.5-250 ng mL-1) for all 19 BP congeners. Furthermore, the simultaneous determination of 19 bromophenols and 19 bromoanisoles, common environmental transformation products of BPs, is also demonstrated. The improved analytical performance on GC-MS after derivatization would benefit investigations on the environmental origins, behaviors and fates of BPs and their environmental metabolites.
Collapse
Affiliation(s)
- Yanwei Liu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; Laboratory of Environmental Nanotechnology and Health Effect, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Xingwang Hou
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Xiaoying Li
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; College of Environmental Science and Engineering, Dalian Maritime University, Dalian, 116026, China
| | - Jiyan Liu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, 100049, China; School of Environment, Hangzhou Institute for Advanced Study, UCAS, Hangzhou, China.
| | - Guibin Jiang
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; College of Resources and Environment, University of Chinese Academy of Sciences, Beijing, 100049, China; School of Environment, Hangzhou Institute for Advanced Study, UCAS, Hangzhou, China
| |
Collapse
|
6
|
Albarri R, Vardara HF, Al S, Önal A. Chromatographic Methods and Sample Pretreatment Techniques for Aldehydes, Biogenic Amine, and Carboxylic Acids in Food Samples. Crit Rev Anal Chem 2024:1-22. [PMID: 38900595 DOI: 10.1080/10408347.2024.2367232] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/22/2024]
Abstract
This review paper critically examines the current state of research concerning the analysis and derivatization of aldehyde, aromatic hydrocarbons and carboxylic acids components in foods and drinks samples, with a specific focus on the application of Chromatographic techniques. These diverse components, as vital contributors to the sensory attributes of food, necessitate accurate and sensitive analytical methods for their identification and quantification, which is crucial for ensuring food safety and compliance with regulatory standards. In this paper, High-Performance Liquid Chromatography (HPLC) and Gas Chromatographic (GC) methods for the separation, identification, and quantification of aldehydes in complex food matrices were reviewed. In addition, the review explores derivatization strategies employed to enhance the detectability and stability of aldehydes during chromatographic analysis. Derivatization methods, when applied judiciously, improve separation efficiency and increase detection sensitivity, thereby ensuring a more accurate and reliable quantification of aldehyde aromatic hydrocarbons and carboxylic acids species in food samples. Furthermore, methodological aspects encompassing sample preparation, chromatographic separation, and derivatization techniques are discussed. Validation was carried out in term of limit of detections are highlighted as crucial elements in achieving accurate quantification of compounds content. The discussion presented by emphasizing the significance of the combined HPLC and GC chromatography methods, along with derivatization strategies, in advancing the analytical capabilities within the realm of food science.
Collapse
Affiliation(s)
- Raneen Albarri
- Faculty of Pharmacy, Department of Analytical Chemistry, Institute of Health Science, Istanbul University, Istanbul, Turkey
| | - Hümeyra Funda Vardara
- Faculty of Pharmacy, Department of Analytical Chemistry, Istanbul University, Istanbul, Turkey
| | - Selen Al
- Faculty of Pharmacy, Department of Analytical Chemistry, Istanbul University, Istanbul, Turkey
| | - Armağan Önal
- Faculty of Pharmacy, Department of Analytical Chemistry, Istanbul University, Istanbul, Turkey
| |
Collapse
|
7
|
Westhoff P, Weber APM. The role of metabolomics in informing strategies for improving photosynthesis. JOURNAL OF EXPERIMENTAL BOTANY 2024; 75:1696-1713. [PMID: 38158893 DOI: 10.1093/jxb/erad508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/13/2023] [Accepted: 12/29/2023] [Indexed: 01/03/2024]
Abstract
Photosynthesis plays a vital role in acclimating to and mitigating climate change, providing food and energy security for a population that is constantly growing, and achieving an economy with zero carbon emissions. A thorough comprehension of the dynamics of photosynthesis, including its molecular regulatory network and limitations, is essential for utilizing it as a tool to boost plant growth, enhance crop yields, and support the production of plant biomass for carbon storage. Photorespiration constrains photosynthetic efficiency and contributes significantly to carbon loss. Therefore, modulating or circumventing photorespiration presents opportunities to enhance photosynthetic efficiency. Over the past eight decades, substantial progress has been made in elucidating the molecular basis of photosynthesis, photorespiration, and the key regulatory mechanisms involved, beginning with the discovery of the canonical Calvin-Benson-Bassham cycle. Advanced chromatographic and mass spectrometric technologies have allowed a comprehensive analysis of the metabolite patterns associated with photosynthesis, contributing to a deeper understanding of its regulation. In this review, we summarize the results of metabolomics studies that shed light on the molecular intricacies of photosynthetic metabolism. We also discuss the methodological requirements essential for effective analysis of photosynthetic metabolism, highlighting the value of this technology in supporting strategies aimed at enhancing photosynthesis.
Collapse
Affiliation(s)
- Philipp Westhoff
- CEPLAS Plant Metabolomics and Metabolism Laboratory, Heinrich-Heine-University, Universitätsstrasse 1, D-40225 Düsseldorf, Germany
| | - Andreas P M Weber
- Institute of Plant Biochemistry, Cluster of Excellence on Plant Science (CEPLAS), Heinrich-Heine-University, Universitätsstrasse 1, D-40225 Düsseldorf, Germany
| |
Collapse
|
8
|
Huang XF, Xue Y, Yong L, Wang TT, Luo P, Qing LS. Chemical derivatization strategies for enhancing the HPLC analytical performance of natural active triterpenoids. J Pharm Anal 2024; 14:295-307. [PMID: 38618252 PMCID: PMC11010456 DOI: 10.1016/j.jpha.2023.07.004] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2023] [Revised: 07/06/2023] [Accepted: 07/06/2023] [Indexed: 04/16/2024] Open
Abstract
Triterpenoids widely exist in nature, displaying a variety of pharmacological activities. Determining triterpenoids in different matrices, especially in biological samples holds great significance. High-performance liquid chromatography (HPLC) has become the predominant method for triterpenoids analysis due to its exceptional analytical performance. However, due to the structural similarities among botanical samples, achieving effective separation of each triterpenoid proves challenging, necessitating significant improvements in analytical methods. Additionally, triterpenoids are characterized by a lack of ultraviolet (UV) absorption groups and chromophores, along with low ionization efficiency in mass spectrometry. Consequently, routine HPLC analysis suffers from poor sensitivity. Chemical derivatization emerges as an indispensable technique in HPLC analysis to enhance its performance. Considering the structural characteristics of triterpenoids, various derivatization reagents such as acid chlorides, rhodamines, isocyanates, sulfonic esters, and amines have been employed for the derivatization analysis of triterpenoids. This review comprehensively summarized the research progress made in derivatization strategies for HPLC detection of triterpenoids. Moreover, the limitations and challenges encountered in previous studies are discussed, and future research directions are proposed to develop more effective derivatization methods.
Collapse
Affiliation(s)
- Xiao-Feng Huang
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Ying Xue
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China
- Sichuan Center for Disease Control and Prevention, Chengdu, 610041, China
| | - Li Yong
- Sichuan Center for Disease Control and Prevention, Chengdu, 610041, China
| | - Tian-Tian Wang
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China
- State Key Laboratory for Quality Research in Chinese Medicines, Macau University of Science and Technology, Macao, China
| | - Pei Luo
- State Key Laboratory for Quality Research in Chinese Medicines, Macau University of Science and Technology, Macao, China
| | - Lin-Sen Qing
- Chengdu Institute of Biology, Chinese Academy of Sciences, Chengdu, 610041, China
| |
Collapse
|
9
|
Ba M, Li W, Song Y, Zhang Y, Xu X, Liu H, Cai Z, Hu S, Liu X, Sun T. Hydroxyl-functionalized pillar[5]arene with high separation performance for gas chromatography. Analyst 2024; 149:925-934. [PMID: 38192226 DOI: 10.1039/d3an01975f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2024]
Abstract
Here we report the first example of employing hydroxyl-functionalized pillar[5]arene (P5A-C10-OH) as stationary phase for capillary gas chromatographic (GC) separations. The statically coated P5A-C10-OH capillary column possessed moderate polarity and column efficiency of 3233 plates per m determined by n-dodecane. As a result, the P5A-C10-OH column exhibited high-resolution capability for the mixture of 17 analytes from apolar to polar nature. Importantly, it exhibited advantageous performance for high resolution of the challenging isomers of bromonitrobenzene, chloroaniline, bromoaniline, iodoaniline and dimethylaniline with good peak shapes over the P5A-C10 and commercial HP-35 columns. In addition, eight cis-/trans-isomers with diverse types were baseline separated on the P5A-C10-OH column. And the application of detecting isomeric impurities in real samples gave strong evidence of its potential and feasibility for the viable GC analysis.
Collapse
Affiliation(s)
- Mengyi Ba
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, P. R. China.
| | - Wen Li
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, P. R. China.
| | - Yanli Song
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, P. R. China.
| | - Yuanyuan Zhang
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, P. R. China.
| | - Xiang Xu
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, P. R. China.
| | - Haixin Liu
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, P. R. China.
| | - Zhiqiang Cai
- Liaoning Province Professional and Technical Innovation Center for Fine Chemical Engineering of Aromatics Downstream, School of Petrochemical Engineering, Shenyang University of Technology, Liaoyang, 111003, Liaoning, P. R. China.
| | - Shaoqiang Hu
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, P. R. China.
| | - Xianming Liu
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, P. R. China.
| | - Tao Sun
- College of Chemistry and Chemical Engineering, Henan Key Laboratory of Function-Oriented Porous Materials, Luoyang Normal University, Luoyang, 471934, P. R. China.
| |
Collapse
|
10
|
Chormey DS, Zaman BT, Borahan Kustanto T, Erarpat Bodur S, Bodur S, Tekin Z, Nejati O, Bakırdere S. Biogenic synthesis of novel nanomaterials and their applications. NANOSCALE 2023; 15:19423-19447. [PMID: 38018389 DOI: 10.1039/d3nr03843b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/30/2023]
Abstract
Despite the many benefits derived from the unique features and practicality of nanoparticles, the release of their toxic by-products or products from the synthesis stage into the environment could negatively impact natural resources and organisms. The physical and chemical methods for nanoparticle synthesis involve high energy consumption and the use of hazardous chemicals, respectively, going against the principles of green chemistry. Biological methods of synthesis that rely on extracts from a broad range of natural plants, and microorganisms, such as fungi, bacteria, algae, and yeast, have emerged as viable alternatives to the physical and chemical methods. Nanoparticles synthesized through biogenic pathways are particularly useful for biological applications that have high concerns about contamination. Herein, we review the physical and chemical methods of nanoparticle synthesis and present a detailed overview of the biogenic methods used for the synthesis of different nanoparticles. The major points discussed in this study are the following: (1) the fundamentals of the physical and chemical methods of nanoparticle syntheses, (2) the use of different biological precursors (microorganisms and plant extracts) to synthesize gold, silver, selenium, iron, and other metal nanoparticles, and (3) the applications of biogenic nanoparticles in diverse fields of study, including the environment, health, material science, and analytical chemistry.
Collapse
Affiliation(s)
- Dotse Selali Chormey
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye.
- Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Türkiye
| | - Buse Tuğba Zaman
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye.
| | - Tülay Borahan Kustanto
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye.
- Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Türkiye
| | - Sezin Erarpat Bodur
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye.
| | - Süleyman Bodur
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye.
- İstinye University, Faculty of Pharmacy, Department of Analytical Chemistry, 34010 İstanbul, Türkiye
- İstinye University, Scientific and Technological Research Application and Research Center, 34010 İstanbul, Türkiye
| | - Zeynep Tekin
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye.
- Neutec Pharmaceutical, Yıldız Technical University Teknopark, 34220, İstanbul, Türkiye
| | - Omid Nejati
- İstinye University, Institute of Health Sciences, Department of Stem Cell and Tissue Engineering, 34010, İstanbul, Türkiye
| | - Sezgin Bakırdere
- Yıldız Technical University, Department of Chemistry, 34220 İstanbul, Türkiye.
- Turkish Academy of Sciences (TÜBA), Vedat Dalokay Street, No: 112, 06670, Çankaya, 06670, Ankara, Türkiye
| |
Collapse
|
11
|
Liu Y, Wu Z, Armstrong DW, Wolosker H, Zheng Y. Detection and analysis of chiral molecules as disease biomarkers. Nat Rev Chem 2023; 7:355-373. [PMID: 37117811 PMCID: PMC10175202 DOI: 10.1038/s41570-023-00476-z] [Citation(s) in RCA: 39] [Impact Index Per Article: 19.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/09/2023] [Indexed: 04/30/2023]
Abstract
The chirality of small metabolic molecules is important in controlling physiological processes and indicating the health status of humans. Abnormal enantiomeric ratios of chiral molecules in biofluids and tissues occur in many diseases, including cancers and kidney and brain diseases. Thus, chiral small molecules are promising biomarkers for disease diagnosis, prognosis, adverse drug-effect monitoring, pharmacodynamic studies and personalized medicine. However, it remains difficult to achieve cost-effective and reliable analysis of small chiral molecules in clinical procedures, in part owing to their large variety and low concentration. In this Review, we describe current and emerging techniques that detect and quantify small-molecule enantiomers and their biological importance.
Collapse
Affiliation(s)
- Yaoran Liu
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, USA
| | - Zilong Wu
- Walker Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX, USA.
- Texas Materials Institute, The University of Texas at Austin, Austin, TX, USA.
| | - Daniel W Armstrong
- Department of Chemistry & Biochemistry, University of Texas at Arlington, Arlington, TX, USA.
| | - Herman Wolosker
- Department of Biochemistry, Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel.
| | - Yuebing Zheng
- Department of Electrical and Computer Engineering, The University of Texas at Austin, Austin, TX, USA.
- Walker Department of Mechanical Engineering, The University of Texas at Austin, Austin, TX, USA.
- Texas Materials Institute, The University of Texas at Austin, Austin, TX, USA.
- Department of Biomedical Engineering, The University of Texas at Austin, Austin, TX, USA.
| |
Collapse
|
12
|
Milić N, Milanović M, Drljača J, Sudji J, Milošević N. Challenges in the Analytical Preparation of a Biological Matrix in Analyses of Endocrine-Disrupting Bisphenols. SEPARATIONS 2023; 10:226. [DOI: 10.3390/separations10040226] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2025] Open
Abstract
Endocrine-disrupting chemicals (EDCs) are xenobiotics presented in a variety of everyday products that may disrupt the normal activity of hormones. Exposure to bisphenol A as EDC at trace and ultra-trace levels is associated with adverse health effects, and children are recognized as the most vulnerable group to EDCs exposure. In this review, a summary is presented of up-to-date sample preparation methods and instrumental techniques applied for the detection and quantification of bisphenol A and its structural analogues in various biological matrices. Biological matrices such as blood, cell-free blood products, urine, saliva, breast milk, cordial blood, amniotic and semen fluids, as well as sweat and hair, are very complex; therefore, the detection and later quantification of bisphenols at low levels present a real analytical challenge. The most popular analytical approaches include gas and liquid chromatography coupled with mass spectrometry, and their enhanced reliability and sensitivity finally allow the separation and detection of bisphenols in biological samples, even as ultra-traces. Liquid/liquid extraction (LLE) and solid-phase extraction (SPE) are still the most common methods for their extraction from biological matrices. However, many modern and environmentally safe microextraction techniques are currently under development. The complexity of biological matrices and low concentrations of analytes are the main issues for the limited identification, as well as understanding the adverse health effects caused by chronical and ubiquitous exposure to bisphenols and its analogues.
Collapse
Affiliation(s)
- Nataša Milić
- Department of Pharmacy, Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 3, 21000 Novi Sad, Serbia
| | - Maja Milanović
- Department of Pharmacy, Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 3, 21000 Novi Sad, Serbia
| | - Jovana Drljača
- Department of Pharmacy, Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 3, 21000 Novi Sad, Serbia
| | - Jan Sudji
- Department of Pharmacy, Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 3, 21000 Novi Sad, Serbia
| | - Nataša Milošević
- Department of Pharmacy, Faculty of Medicine, University of Novi Sad, Hajduk Veljkova 3, 21000 Novi Sad, Serbia
| |
Collapse
|
13
|
Yin C, Harms AC, Hankemeier T, Kindt A, de Lange ECM. Status of Metabolomic Measurement for Insights in Alzheimer's Disease Progression-What Is Missing? Int J Mol Sci 2023; 24:ijms24054960. [PMID: 36902391 PMCID: PMC10003384 DOI: 10.3390/ijms24054960] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 02/24/2023] [Accepted: 03/02/2023] [Indexed: 03/08/2023] Open
Abstract
Alzheimer's disease (AD) is an aging-related neurodegenerative disease, leading to the progressive loss of memory and other cognitive functions. As there is still no cure for AD, the growth in the number of susceptible individuals represents a major emerging threat to public health. Currently, the pathogenesis and etiology of AD remain poorly understood, while no efficient treatments are available to slow down the degenerative effects of AD. Metabolomics allows the study of biochemical alterations in pathological processes which may be involved in AD progression and to discover new therapeutic targets. In this review, we summarized and analyzed the results from studies on metabolomics analysis performed in biological samples of AD subjects and AD animal models. Then this information was analyzed by using MetaboAnalyst to find the disturbed pathways among different sample types in human and animal models at different disease stages. We discuss the underlying biochemical mechanisms involved, and the extent to which they could impact the specific hallmarks of AD. Then we identify gaps and challenges and provide recommendations for future metabolomics approaches to better understand AD pathogenesis.
Collapse
Affiliation(s)
- Chunyuan Yin
- Metabolomics and Analytics Centre, Leiden Academic Centre for Drug Research, Leiden University, 2333 CC Leiden, The Netherlands
- Division of Systems Pharmacology and Pharmacy, Leiden Academic Centre for Drug Research, Leiden University, 2333 CC Leiden, The Netherlands
| | - Amy C. Harms
- Metabolomics and Analytics Centre, Leiden Academic Centre for Drug Research, Leiden University, 2333 CC Leiden, The Netherlands
| | - Thomas Hankemeier
- Metabolomics and Analytics Centre, Leiden Academic Centre for Drug Research, Leiden University, 2333 CC Leiden, The Netherlands
| | - Alida Kindt
- Metabolomics and Analytics Centre, Leiden Academic Centre for Drug Research, Leiden University, 2333 CC Leiden, The Netherlands
| | - Elizabeth C. M. de Lange
- Division of Systems Pharmacology and Pharmacy, Leiden Academic Centre for Drug Research, Leiden University, 2333 CC Leiden, The Netherlands
- Correspondence:
| |
Collapse
|
14
|
Fitzsimons MF, Tilley M, Cree CHL. The determination of volatile amines in aquatic marine systems: A review. Anal Chim Acta 2023; 1241:340707. [PMID: 36657869 DOI: 10.1016/j.aca.2022.340707] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 12/01/2022] [Accepted: 12/04/2022] [Indexed: 12/13/2022]
Abstract
This review provides a critical assessment of knowledge regarding the determination of volatile, low molecular weight amines, and particularly methylamines, in marine aquatic; systems. It provides context for the motivation to determine methylamines in the marine aquatic environment and the analytical challenges associated with their measurement.While sensitive analytical methods have been reported in recent decades, they have not been adopted by the oceanographic community to investigate methylamines' biogeochemistry and advance understanding of these analytes to the degree achieved for other marine volatiles. Gas chromatography, high performance liquid chromatography, ion chromatography and infusion-mass spectrometry techniques are discussed and critically determined, alongside offline and online preconcentration steps. Interest in the marine occurrence and cycling of methylamines has increased within the last 10-15 years, due to their potential role in climate regulation. As such, the need for robust, reproducible methods to elucidate biogeochemical cycles for nitrogen and populate marine models is apparent. Recommendations are made as to what equipment would be most suitable for future research in this area.
Collapse
Affiliation(s)
- Mark F Fitzsimons
- Biogeochemistry Research Centre, School of Geography, Earth and Environmental Sciences, University of Plymouth, PL4 8AA, UK.
| | - Mia Tilley
- Biogeochemistry Research Centre, School of Geography, Earth and Environmental Sciences, University of Plymouth, PL4 8AA, UK
| | - Charlotte H L Cree
- Biogeochemistry Research Centre, School of Geography, Earth and Environmental Sciences, University of Plymouth, PL4 8AA, UK
| |
Collapse
|
15
|
Liu C, Xie X, Guo Y, Wang B, Xie K, Dong Y, Yang C, Feng Z, Bao W. Pre-column derivatization with trimethylsilyl diazomethane coupled with ASE-SPE-GC-MS/MS method for the quantification and validation of penicillin G residues in poultry tissues and pork. J Food Compost Anal 2023. [DOI: 10.1016/j.jfca.2022.104866] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
16
|
Temerdashev ZA, Vinitskaya EA, Korobkova VV. Determination of Phenolic Compounds in Hypericum perforatum L. Aqueous Extracts by Gas Chromatography–Mass Spectrometry Using Solid-Phase Analytical Derivatization. JOURNAL OF ANALYTICAL CHEMISTRY 2022. [DOI: 10.1134/s1061934822110120] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
|
17
|
Sun Z, Qi M. High separation performance of carbon dioxide-based poly(ether-carbonate) copolymer for gas chromatographic analyses. J Chromatogr A 2022; 1682:463493. [PMID: 36166885 DOI: 10.1016/j.chroma.2022.463493] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Revised: 09/05/2022] [Accepted: 09/07/2022] [Indexed: 11/16/2022]
Abstract
This work presents the investigation of a novel CO2-based poly(ether-carbonate) copolymer, namely poly(propylene ether-carbonate)diol (PPCD), for gas chromatographic (GC) analyses. The PPCD column exhibited column efficiency of 4000 plates/m determined by naphthalene at 120 ℃ with the retention factor 6.23. Its separation performance was investigated by adopting a wide variety of analytes and isomers, including the isomer mixtures of alkanes, substituted benzene isomers with diverse groups, phenols and anilines, and the mixtures of organic solvents of high volatility, aliphatic amines and N-heterocycles. As a result, the PPCD column displayed distinctly higher resolving capability than the commercial columns described herein and achieved high column inertness towards acidic/basic analytes without involving any deactivation procedure. Additionally, it displayed excellent separation repeatability and reproducibility with the relative standard deviation (RSD) values less than 0.01% for within-day and in the range of 0.26% - 0.36% for between-day and 3.0% - 4.1% for between-column (n = 4). Further, the PPCD column (30 m) was used to GC-MS analysis of the lemongrass essential oil and resolved more components well than the indicated commercial columns, evidencing its outstanding separation performance for analyses of complex samples. Up to date, the CO2-based poly(ether-carbonate) copolymers are not reported in the field of chromatography. This work demonstrates their promising future as a new type of selective and inert stationary phases for practical GC analyses.
Collapse
Affiliation(s)
- Ziqi Sun
- Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China
| | - Meiling Qi
- Key Laboratory of Cluster Science, Ministry of Education of China, Beijing Key Laboratory of Photoelectronic/Electrophotonic Conversion Materials, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing 100081, China.
| |
Collapse
|
18
|
Erarpat S, Bodur S, Öner M, Günkara ÖT, Bakırdere S. A simple and efficient derivatization strategy combined with switchable solvent liquid-liquid microextraction hydroxychloroquine methyl acetate-d 3 -based quadruple isotope dilution gas chromatography mass spectrometry for the determination of hydroxychloroquine sulfate in biological fluids. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2022; 36:e9282. [PMID: 35229402 DOI: 10.1002/rcm.9282] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 01/15/2022] [Accepted: 02/22/2022] [Indexed: 06/14/2023]
Abstract
RATIONALE A derivatization switchable solvent liquid-liquid microextraction quadruple isotope dilution gas chromatography mass spectrometry (D-SS-LLME-ID4 -GC/MS) method is presented for the determination of hydroxychloroquine sulfate in human biofluids. METHODS While mixing type/period and concentration of NaOH were optimized via a univariate optimization approach, a multivariate optimization approach was used to determine optimum values for relatively more important parameters such as volumes of derivatization agent (acetic anhydride), NaOH and switchable solvent. RESULTS Under the optimum experimental conditions, limit of detection and limit of quantification were calculated as 0.03 and 0.09 mg/kg (mass based), respectively. An isotopically labelled material (hydroxychloroquine methyl acetate-d3 ) was firstly synthesized to be used in ID4 experiments which give highly accurate and precise recovery results. After the application of D-SS-LLME-ID4 , superior percent recovery results were recorded as 99.9 ± 1.6-101.3 ± 1.2 for human serum, 99.9 ± 1.7-99.8 ± 1.8 for urine and 99.6 ± 1.5-101.0 ± 1.1 for saliva samples. CONCLUSIONS The developed D-SS-LLME-ID4 -GC/MS method compensates the complicated matrix effects of human biofluids and provides highly accurate quantification of an analyte with precise results.
Collapse
Affiliation(s)
- Sezin Erarpat
- Faculty of Art and Science, Chemistry Department, Yıldız Technical University, İstanbul, Turkey
| | - Süleyman Bodur
- Faculty of Art and Science, Chemistry Department, Yıldız Technical University, İstanbul, Turkey
| | - Miray Öner
- Faculty of Art and Science, Chemistry Department, Yıldız Technical University, İstanbul, Turkey
| | - Ömer Tahir Günkara
- Faculty of Art and Science, Chemistry Department, Yıldız Technical University, İstanbul, Turkey
| | - Sezgin Bakırdere
- Faculty of Art and Science, Chemistry Department, Yıldız Technical University, İstanbul, Turkey
- Turkish Academy of Sciences (TÜBA), Ankara, Turkey
| |
Collapse
|
19
|
Abdelgawad MA, Abdelaleem EA, Gamal M, Abourehab MAS, Abdelhamid NS. A new green approach for the reduction of consumed solvents and simultaneous quality control analysis of several pharmaceuticals using a fast and economic RP-HPLC method; a case study for a mixture of piracetam, ketoprofen and omeprazole drugs. RSC Adv 2022; 12:16301-16309. [PMID: 35733689 PMCID: PMC9159347 DOI: 10.1039/d2ra02395d] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2022] [Accepted: 05/18/2022] [Indexed: 11/28/2022] Open
Abstract
One of the main aims of green analytical chemistry (GAC) is the reduction of solvents and chemicals consumed. Recycling the mobile phase in chromatographic techniques provides an efficient way to implement GAC principles. However, this is not an easy job, particularly in the case of the gradient mode. Analysis of multi-pharmaceuticals for the same manufacturer using one mobile phase system dramatically reduces consumed solvents, time, and cost for pharmaceuticals analysis in quality control laboratories. This work is an attempt to reduce time, cost and effort needed for quality control analysis of several dosage forms produced by the same manufacturer. Our novel and green RP-HPLC method is able to separate and quantify a tertiary mixture of piracetam, ketoprofen and omeprazole produced by the same manufacturers. The analyst can easily quantify the three drugs in the three dosage forms in one run using the gradient elution mode of methanol and water (from 50% methanol to 85% methanol in ten minutes) with a flow rate 1.5 mL min−1 on a non-polar C18 column. Suitable dilutions were done for the working solution of the mixed pharmaceutical formulations prior to chromatographic analysis. This procedure will dramatically reduce the consumed solvents and save time and money during pharmaceutical analysis. The calibration ranges are (5–25), (5–25) and (3–20) μg mL−1 for the three studied drugs. The International Council for Harmonization (ICH) procedures were followed in the validation process and the results were evaluated in comparison with official HPLC methods, where no noteworthy differences were found. The green profile of the method and pictograms of AGREE and Green Analytical Procedure Index (GAPI) approaches proved the eco-friendly character for the studied drugs. The simultaneous quantitative analysis for Stimulan® and Hyposec® capsules, and Ketolgin® tablets from the Amoun Pharmaceutical Company, Egypt, can be accomplished via the novel method. Also, Memoral® ampoules, Topfam® tablets, and Gastroloc® capsules from Sigma Pharmaceutical Industries, Egypt, could be analyzed simultaneously. Omez® capsules and Ketogesic® tablets from the Pharaonia Pharmaceuticals, Egypt, could be determined simultaneously too. Applying this RP-HPLC method, a significant reduction of the total cost is assured as the required amount of solvent is noticeably decreased when performing multi-analyses in comparison to single component analysis. We report a novel and green RP-HPLC method able to separate and quantify a tertiary mixture of piracetam, ketoprofen and omeprazole produced by the same manufacturers.![]()
Collapse
Affiliation(s)
- Mohamed A Abdelgawad
- Department of Pharmaceutical Chemistry, College of Pharmacy, Jouf University Aljouf 72341 Saudi Arabia
| | - Eglal A Abdelaleem
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Beni-Suef University Alshaheed Shehata Ahmad Hegazy St. 62514 Beni-Suef Egypt
| | - Mohammed Gamal
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Beni-Suef University Alshaheed Shehata Ahmad Hegazy St. 62514 Beni-Suef Egypt
| | - Mohammed A S Abourehab
- Department of Pharmaceutics, Faculty of Pharmacy, Umm Al-Qura University Makkah 21955 Saudi Arabia
| | - Nessreen S Abdelhamid
- Pharmaceutical Analytical Chemistry Department, Faculty of Pharmacy, Beni-Suef University Alshaheed Shehata Ahmad Hegazy St. 62514 Beni-Suef Egypt
| |
Collapse
|
20
|
Duan R, Qi M. Separation performance of pentiptycene-functionalized triblock copolymers towards the isomers of xylenes, phenols and anilines and the complex components in essential oil. J Chromatogr A 2022; 1669:462927. [DOI: 10.1016/j.chroma.2022.462927] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2022] [Revised: 02/22/2022] [Accepted: 03/01/2022] [Indexed: 10/19/2022]
|
21
|
Mao X, Wang Y, Jiang L, Zhang H, Zhao Y, Liu P, Liu J, Hammock BD, Zhang C. A Polydopamine-Coated Gold Nanoparticles Quenching Quantum Dots-Based Dual-Readout Lateral Flow Immunoassay for Sensitive Detection of Carbendazim in Agriproducts. BIOSENSORS 2022; 12:bios12020083. [PMID: 35200343 PMCID: PMC8869244 DOI: 10.3390/bios12020083] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 01/27/2022] [Accepted: 01/28/2022] [Indexed: 06/12/2023]
Abstract
In this study, a fluorometric and colorimetric dual-readout lateral flow immunoassay (LFIA) using antibody functionalized polydopamine-coated gold nanoparticles (Au@PDAs) as a probe was developed for the detection of carbendazim (CBD). Colloidal gold nanoparticles (AuNPs) were coated with polydopamines (PDA) by the oxidation of dopamine to synthesize Au@PDA nanoparticles. The Au@PDA nanoparticles mediated ZnCdSe/ZnS quantum dots (QDs) fluorescence quenching and recovery, resulting in a reverse fluorescence enhancement detection format of CBD. The CBD detection was obtained by the competition between the CBD and the immobilized antigen for Au@PDAs labelled antibody binding, resulting in a significant fluorescence increase and colorimetry decrease corresponded to the concentration of CBD. Dual readout modes were incorporated into the LFIA using the colorimetry signal under natural light and the fluorescence signal under UV light. The cut-off value in the mode of the colorimetric signal and fluorometric signal for CBD detection was 0.5 μg/mL and 0.0156 μg/mL, respectively. The sensitivity of LFIA of the fluorescence mode was 32 times higher than that of the colorimetry mode. There was negligible cross reactivity obtained by using LFIA for the determination of thiabendazole, benomyl, thiophanate-methyl, and thiophanate-ethyl. Consistent and satisfactory results have been achieved by comparing the results of Au@PDAs-QDs-LFIA and liquid chromatography-tandem mass spectrometry (LC-MS/MS) testing spiked cucumber and strawberry samples, indicating good reliability of the Au@PDAs-QDs-LFIA.
Collapse
Affiliation(s)
- Xinxin Mao
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; (X.M.); (L.J.); (J.L.)
- Key Lab of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding Base, Ministry of Agriculture, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China; (Y.W.); (H.Z.); (Y.Z.); (P.L.)
| | - Yulong Wang
- Key Lab of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding Base, Ministry of Agriculture, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China; (Y.W.); (H.Z.); (Y.Z.); (P.L.)
| | - Lan Jiang
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; (X.M.); (L.J.); (J.L.)
| | - Hanxiaoya Zhang
- Key Lab of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding Base, Ministry of Agriculture, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China; (Y.W.); (H.Z.); (Y.Z.); (P.L.)
| | - Yun Zhao
- Key Lab of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding Base, Ministry of Agriculture, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China; (Y.W.); (H.Z.); (Y.Z.); (P.L.)
| | - Pengyan Liu
- Key Lab of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding Base, Ministry of Agriculture, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China; (Y.W.); (H.Z.); (Y.Z.); (P.L.)
| | - Juanjuan Liu
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; (X.M.); (L.J.); (J.L.)
| | - Bruce D. Hammock
- Department of Entomology and Nematology, UCD Comprehensive Cancer Center, University of California, Davis, CA 95616, USA;
| | - Cunzheng Zhang
- College of Plant Protection, Nanjing Agricultural University, Nanjing 210095, China; (X.M.); (L.J.); (J.L.)
- Key Lab of Food Quality and Safety of Jiangsu Province-State Key Laboratory Breeding Base, Ministry of Agriculture, Institute of Food Safety and Nutrition, Jiangsu Academy of Agricultural Sciences, Nanjing 210014, China; (Y.W.); (H.Z.); (Y.Z.); (P.L.)
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang 330047, China
- School of Biology and Food Engineering, Jiangsu University, Zhenjiang 212000, China
| |
Collapse
|
22
|
Li S, Li J, Feng S, Bian L, Liu Z, Ping Y, Wang X, Van Schepdael A. Headspace solid-phase microextraction and on-fiber derivatization for the determination of 3-/2-MCPDE and GE in breast milk and infant formula by gas chromatography tandem mass spectrometry. Lebensm Wiss Technol 2022. [DOI: 10.1016/j.lwt.2021.112575] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
23
|
Ye D, Li X, Shen J, Xia X. Microbial metabolomics: From novel technologies to diversified applications. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116540] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
24
|
Mutyam S, Chilakala S, Tallapally M, Upadhyayula VVR. Gas chromatography-mass spectrometric determination of organic acids in fruit juices by multiwalled carbon nanotube-based ion-pair dispersive solid-phase extraction and in situ butylation. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2021; 35:e9165. [PMID: 34260110 DOI: 10.1002/rcm.9165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Revised: 06/25/2021] [Accepted: 07/11/2021] [Indexed: 06/13/2023]
Abstract
RATIONALE Fruit juices are naturally acidic, and the acidity is due to the formation of various organic acids formed in several metabolic processes. The content of acids varies due to various processing parameters during the preparation of fruit juices and their packaging for commercialization. Quantitative determination of organic acids provides the necessary information leading to changes occurred during processing. METHODS The organic acids were extracted by ion-pair dispersive solid-phase extraction by multiwalled carbon nanotubes and analyzed using gas chromatography-mass spectrometry (GC-MS) and in situ butylation. RESULTS The developed analytical method was validated, and the obtained results showed a linearity in the range of 0.5-5000 μg/L levels of the analytes with limit of detection and quantification values of 2-10 and 5-20 μg/L, respectively. The inter- and intra-day reproducibilities are less than 15% with 80%-98% recoveries and less than 20% matrix effect. The developed method was used for the quantitative determination of organic acids present in fresh and packaged apple, grape, orange, and pomegranate juice samples. The content of organic acids was observed in the range of 0.26-3793 μg/L. Pimelic acid was not detected in any of the analyzed fruit juices. Fumaric acid (FA) was observed to be a major organic diacid present in the natural fruit juices. The results indicated that the processing of fruit juices for packaging decreases the content of organic acids in fruits. CONCLUSIONS The developed GC-MS-based analytical method for the analysis of organic acids has good sensitivity and reproducibility for the quantitative determination of various organic acids in fruit juices. FA was observed to be the major carboxylic acid present in fruits. The processed juice samples possess the lowest concentration of organic acids, suggesting that processing has a significant effect on the concentration of organic acids in fruits.
Collapse
Affiliation(s)
- Satish Mutyam
- Analytical and Structural Chemistry Division, Centre for Mass Spectrometry, CSIR-Indian Institute of Chemical Technology, Hyderabad, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| | - Shireesha Chilakala
- Analytical and Structural Chemistry Division, Centre for Mass Spectrometry, CSIR-Indian Institute of Chemical Technology, Hyderabad, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| | - Maheshwari Tallapally
- Analytical and Structural Chemistry Division, Centre for Mass Spectrometry, CSIR-Indian Institute of Chemical Technology, Hyderabad, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| | - Vijayasarathi V R Upadhyayula
- Analytical and Structural Chemistry Division, Centre for Mass Spectrometry, CSIR-Indian Institute of Chemical Technology, Hyderabad, India
- Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, India
| |
Collapse
|
25
|
Peng LQ, Cao J. Modern microextraction techniques for natural products. Electrophoresis 2020; 42:219-232. [PMID: 33215711 DOI: 10.1002/elps.202000248] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 10/16/2020] [Accepted: 11/03/2020] [Indexed: 11/11/2022]
Abstract
Natural product analysis has gained wide attention in recent years, especially for herbal medicines, which contain complex ingredients and play a significant clinical role in the therapy of numerous diseases. The constituents of natural products are usually found at low concentrations, and the matrices are complex. Thus, the extraction of target compounds from natural products before analysis by analytical instruments is very significant for human health and its wide application. The commonly used traditional extraction methods are time-consuming, using large amounts of sample and organic solvents, as well as expensive and inefficient. Recently, microextraction techniques have been used for natural product extraction to overcome the disadvantages of conventional extraction methods. In this paper, the successful applications of and recent developments in microextraction techniques including solvent-based and sorbent-based microextraction methods, in natural product analysis in recent years, especially in the last 5 years, are reviewed for the first time. Their features, advantages, disadvantages, and future development trends are also discussed.
Collapse
Affiliation(s)
- Li-Qing Peng
- College of Pharmaceutical Sciences, Hangzhou Normal University, Hangzhou, 311121, P. R. China
| | - Jun Cao
- College of Pharmaceutical Sciences, Hangzhou Normal University, Hangzhou, 311121, P. R. China.,College of Material Chemistry and Chemical Engineering, Hangzhou Normal University, Hangzhou, 311121, P. R. China
| |
Collapse
|
26
|
Afshar Mogaddam MR, Farajzadeh MA, Mohebbi A, Nemati M. Hollow fiber–liquid phase microextraction method based on a new deep eutectic solvent for extraction and derivatization of some phenolic compounds in beverage samples packed in plastics. Talanta 2020; 216:120986. [DOI: 10.1016/j.talanta.2020.120986] [Citation(s) in RCA: 45] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 03/26/2020] [Accepted: 03/28/2020] [Indexed: 11/15/2022]
|
27
|
Direct Immersion Single-Drop Microextraction and Continuous-Flow Microextraction for the Determination of Manganese in Tonic Drinks and Seafood Samples. FOOD ANAL METHOD 2020. [DOI: 10.1007/s12161-020-01794-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
|
28
|
Garzón-Serrano AY, Sierra CA, Rodríguez-Bejarano O, Sinuco D. Volatile Organic Compounds, Spectral Characterization and Morphology of Ammonium Nitrate Fuel Oil (ANFO) Samples. J Forensic Sci 2020; 65:1085-1093. [PMID: 32176825 DOI: 10.1111/1556-4029.14312] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 02/08/2020] [Accepted: 02/10/2020] [Indexed: 11/30/2022]
Abstract
Ammonium nitrate fuel oil is an explosive mixture found in most antipersonnel landmines (APL) buried throughout the Colombian territory. During more than 50 years of internal conflict, the Colombian government has found that trained dogs are the most effective method to detect APL. However, the olfactive signature in ANFO is unknown and also if there are differences in detection related to the explosive manufacturing origin. Therefore, this work begins with the analytical validation of the method used to determine ammonia, in its derivatized form as carbamate, released by home-made ANFO using HS-SPME-GC-FID. Once validated, the method was used to identify ammonia and other organic volatile compounds present in ANFO, under laboratory and simulated field conditions. The validation process includes the evaluation of the optimum conditions for the derivation and extraction of butylcarbamate, the determination of the working ranges with linear response in FID, the limits of detection and quantification, the sensitivity, and the precision. The results of the validation established linearity and sensitivity in a concentration between 20 and 120 mg/L, as well as low limits of detection and quantification of 6.4 and 21.4 mg/L, respectively. Also, an intermediate precision of 11% for butylcarbamate with a repeatability of 8%. The validated method showed in real samples of home-made ANFO besides ammonia, the presence of low molecular methylamines, and also exhibited differences in volatile compositions according to the origin. The objective of this work is to offer a reliable analytical methodology for the extraction and analysis of volatile compounds from ANFO.
Collapse
Affiliation(s)
- Andrea Y Garzón-Serrano
- Facultad de Ciencias, Departamento de Química, Grupo de Investigación en Macromoléculas (Macromolecules Research Group), Universidad Nacional de Colombia, Sede Bogotá, Ciudad Universitaria, Bogotá, Colombia.,Facultad de Ciencias, Departamento de Química, Bioprospección de Compuestos Volátiles (Volatile Compounds Bioprospecting), Universidad Nacional de Colombia, Sede Bogotá, Ciudad Universitaria, Bogotá, Colombia
| | - César A Sierra
- Facultad de Ciencias, Departamento de Química, Grupo de Investigación en Macromoléculas (Macromolecules Research Group), Universidad Nacional de Colombia, Sede Bogotá, Ciudad Universitaria, Bogotá, Colombia
| | - Oscar Rodríguez-Bejarano
- Facultad de Ciencias, Departamento de Química, Grupo de Electroquímica y Termodinámica Computacional (Electrochemistry and Computational Thermodynamics Group), Universidad Nacional de Colombia, Sede Bogotá, Ciudad Universitaria, Bogotá, Colombia
| | - Diana Sinuco
- Facultad de Ciencias, Departamento de Química, Bioprospección de Compuestos Volátiles (Volatile Compounds Bioprospecting), Universidad Nacional de Colombia, Sede Bogotá, Ciudad Universitaria, Bogotá, Colombia
| |
Collapse
|
29
|
Abstract
It is not a simple task to develop techniques for analyzing tricyclic quaternary ammonium alkaloids (TCQAAs) because of the relative polarity and alkalinity of the latter.
Collapse
Affiliation(s)
- Mohammed Gamal
- Department of Pharmaceutical Chemistry
- Pharmacy College
- Jouf University
- Aljouf
- Kingdom of Saudi Arabia
| |
Collapse
|
30
|
Shi T, Qi M, Huang X. High-resolution performance of triptycene functionalized with polycaprolactones for gas chromatography. J Chromatogr A 2019; 1614:460714. [PMID: 31761436 DOI: 10.1016/j.chroma.2019.460714] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 11/13/2019] [Accepted: 11/14/2019] [Indexed: 12/18/2022]
Abstract
Developing highly selective stationary phases is essential to address the issues for separation of analytes with similar properties and various components in complex samples. Herein, we report a new triptycene-based material functionalized with polycaprolactone moieties (TP-PCL) as the stationary phase with high-resolution performance for gas chromatography (GC). The TP-PCL capillary column exhibited column efficiency of 5555 plates/m and moderate polarity. On the column, dozens of mixtures of positional and structural isomers can be well resolved, involving benzene derivatives with varying substituents (alkyl, halo, nitro, hydroxyl, amino), naphthalene derivatives, alkanes and alcohols. It exhibits advantageous performance for high resolution of the critical pairs of alkylbenzenes, phenols, anilines and alkanes over the PCL column and commercial DB-35 MS column with similar polarity. Moreover, the TP-PCL column showed excellent separation repeatability and reproducibility with RSD values of 0.02%-0.07% for run-to-run (n = 4), 0.11%-0.18% for day-to-day (n = 4) and 2.1%-4.7% for column-to-column (n = 4). In addition, it exhibited distinctly enhanced thermal stability in contrast to the PCL column. Its application to analysis of the essential oil from Artemisiae argyi proves its good potential for practical use.
Collapse
Affiliation(s)
- Tiantian Shi
- Key Laboratory of Cluster Science, Ministry of Education of China, and School of Chemistry and Chemical Engineering, Analysis & Testing Center, Beijing Institute of Technology, Beijing 100081, China
| | - Meiling Qi
- Key Laboratory of Cluster Science, Ministry of Education of China, and School of Chemistry and Chemical Engineering, Analysis & Testing Center, Beijing Institute of Technology, Beijing 100081, China.
| | - Xuebin Huang
- Key Laboratory of Cluster Science, Ministry of Education of China, and School of Chemistry and Chemical Engineering, Analysis & Testing Center, Beijing Institute of Technology, Beijing 100081, China.
| |
Collapse
|
31
|
Xiong X, Qi M. Adenine-functionalized polypropylene glycol: A novel stationary phase for gas chromatography offering good inertness for acids and bases combined with a unique selectivity. J Chromatogr A 2019; 1612:460627. [PMID: 31668867 DOI: 10.1016/j.chroma.2019.460627] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2019] [Revised: 10/10/2019] [Accepted: 10/15/2019] [Indexed: 12/15/2022]
Abstract
This work presents the investigation of utilizing adenine-functionalized polypropylene glycol (APPG) for capillary gas chromatographic separations. The statically coated APPG column (0.25 mm i.d.) showed moderate polarity and high column efficiencies of 4660 plates/m and 4376 plates/m determined by n-octanol and naphthalene, respectively. Remarkably, the APPG column baseline resolved all the components of the Grob test mixture and displayed good peak shapes for some stringent analytes that are prone to peak tailing or severe adsorption. Also, it achieved complete separation of dimethylaniline isomers, which are difficult to be resolved due to their high resemblance in structures and properties. The above results demonstrate the high selectivity and inertness of the APPG column and its distinct advantages over the polypropylene glycol (PPG) column and commercial polyethylene glycol (PEG) column. In addition, its separation performance has good repeatability with the RSD values on retention times below 0.05% for run-to-run, 0.11-0.12% for day-to-day and 1.7-1.9% for column-to-column, respectively. Further, the APPG column was applied to determination of isomer impurities in commercial dimethylaniline products and to determination of the additives of anilines and phenols in a hair-dye product, proving its great potential for practical GC analysis.
Collapse
Affiliation(s)
- Xue Xiong
- Key Laboratory of Cluster Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, and Analysis & Testing Center, Beijing Institute of Technology, Beijing, 100081, China
| | - Meiling Qi
- Key Laboratory of Cluster Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, and Analysis & Testing Center, Beijing Institute of Technology, Beijing, 100081, China.
| |
Collapse
|
32
|
Direct in situ labeling of target drugs with a fluorophore probe to improve MALDI-MS detection sensitivity in micro-liter plasma. Sci Rep 2019; 9:10787. [PMID: 31346224 PMCID: PMC6658545 DOI: 10.1038/s41598-019-47147-y] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2019] [Accepted: 07/10/2019] [Indexed: 12/17/2022] Open
Abstract
Nonsteroidal anti-inflammatory drugs (NSAIDs) are widely used for symptomatic relief from fever, inflammation, and chronic pain associated with a variety of human disorders. Long-term usage of these drugs can result in severe syndromes; hence, their dose should be controlled carefully and their side effects such as Stevens–Johnson syndrome, toxic epidermal necrolysis, phototoxicity, acute interstitial nephritis, gastrointestinal bleeding, cardiovascular diseases, and liver injury should be considered. Furthermore, the widely used combination of NSAIDs as over-the-counter (OTC) drugs with other drugs leads to adverse drug–drug interactions. Therefore, development of a throughput method to rapidly screen 20 NSAIDs in biological samples is necessary to safeguard human health. In this work, we selected a suitable fluorophore probe coupled with in situ micro-labeling (<2 min) on stainless plate for the fast detection of NSAIDs in plasma samples at the micro-liter level (5 μL) without complicated sample preparation and separation. Every step undertaken in the protocol was also at the micro-liter level; thus, a small amount of blood collected from the human finger will suffice to determine the drug concentration in blood using the proposed method. Furthermore, the proposed method we developed was also matched the modern trends of green analytical chemistry towards miniaturization of analytical methodologies.
Collapse
|
33
|
Yu L, He J, Qi M, Huang X. Amphiphilic triptycene-based stationary phase for high-resolution gas chromatographic separations. J Chromatogr A 2019; 1599:239-246. [PMID: 31005291 DOI: 10.1016/j.chroma.2019.04.033] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2019] [Revised: 04/10/2019] [Accepted: 04/11/2019] [Indexed: 12/16/2022]
Abstract
This work reports a new type of triptycene-based amphiphilic stationary phase (TP-2IL) for gas chromatography (GC). It is an integration of the 3D π-rich triptycene framework with ionic liquids. Its capillary column showed the efficiency of 3880 plates/m determined by n-dodecane at 120 °C (k = 2.79) and exhibited good performance for analytes from apolar to polar nature. Particularly, it has outstanding capability for resolving critical pairs of anilines and phenols with good peak shapes and shows distinct advantages over its composing counterparts (TP-2BO and O-IL) and widely-used commercial columns, namely 35% phenyl methyl polysiloxane (DB-35) and polyethylene glycol (INNOWAX). Moreover, the TP-2IL column exhibited good repeatability and reproducibility with the values of relative standard deviation in the range of 0.02%-0.07% for run-to-run, 0.10%-0.35% for day-to-day and 2.9%-5.1% for column-to-column, respectively, and good thermal stability up to 300 °C. Furthermore, its applications for determining isomer impurities in real samples demonstrate its feasibility for practical GC analysis. This work presents a facile strategy for constructing triptycene-based stationary phases with amphiphilic selectivity and provides alternatives of highly selective stationary phases for chromatographic analysis.
Collapse
Affiliation(s)
- Lining Yu
- Key Laboratory of Cluster Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, and Analysis & Testing Center, Beijing Institute of Technology, Beijing, 100081, China
| | - Jun He
- Key Laboratory of Cluster Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, and Analysis & Testing Center, Beijing Institute of Technology, Beijing, 100081, China
| | - Meiling Qi
- Key Laboratory of Cluster Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, and Analysis & Testing Center, Beijing Institute of Technology, Beijing, 100081, China.
| | - Xuebin Huang
- Key Laboratory of Cluster Science, Ministry of Education of China, School of Chemistry and Chemical Engineering, and Analysis & Testing Center, Beijing Institute of Technology, Beijing, 100081, China.
| |
Collapse
|
34
|
Wang L, Wang Y, Wang W, Zheng F, Chen F. Comparison of volatile compositions of 15 different varieties of Chinese jujube ( Ziziphus jujuba Mill.). Journal of Food Science and Technology 2019; 56:1631-1640. [PMID: 30956344 DOI: 10.1007/s13197-019-03689-7] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Revised: 01/19/2019] [Accepted: 02/24/2019] [Indexed: 11/30/2022]
Abstract
Jujube (Ziziphus jujuba Mill.) extract has been commonly used as a flavoring ingredient due to its unique aroma. In this study, solid phase micro extraction method was used to extract the volatile compounds in fresh jujube, with the aid of GC-MS for further chemical separation and identification. As a result, 33 volatile compounds, including aldehydes, alcohols, acids, ketones and esters, were identified. Among them, hexanal (276.5-1314 μg/100 g FW), (E)-2-hexanal, (145.1-1876 μg/100 g FW), nonanal (188.2-1047 μg/100 g FW), and n-decanoic acid (58.42-1268 μg/100 g FW) were found to be the major volatile compounds in fresh jujube fruit. Based on the type and amounts of the volatile compounds, 15 Chinese jujube cultivars were divided into 5 clusters through hierarchical cluster analysis and principal component analysis (PCA). Fiver clusters include cluster 1 (LB, HP, LZ, NP, JS, PZ, and YL), cluster 2 (BJ, DB), cluster 3 (PB, BZ, JD and XZ), cluster 4 (JB) and cluster 5 (YZ). According to the PCA, the clusters 1, 2 and 3 could not be discriminated from each other, but clusters 4 and 5 could be separated very well from each other.
Collapse
Affiliation(s)
- Lina Wang
- 1Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, 100048 China.,2Department of Food, Nutrition and Packaging Sciences, Clemson University, Clemson, SC 29634 USA
| | - Yaqi Wang
- 1Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, 100048 China
| | - Weizheng Wang
- 1Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, 100048 China
| | - Fuping Zheng
- 1Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, 100048 China
| | - Feng Chen
- 1Advanced Innovation Center for Food Nutrition and Human Health, Beijing Technology and Business University, Beijing, 100048 China.,2Department of Food, Nutrition and Packaging Sciences, Clemson University, Clemson, SC 29634 USA
| |
Collapse
|
35
|
Guidetti Vendruscolo R, Bittencourt Fagundes M, Jacob-Lopes E, Wagner R. Analytical strategies for using gas chromatography to control and optimize microalgae bioprocessing. Curr Opin Food Sci 2019. [DOI: 10.1016/j.cofs.2019.02.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
36
|
Sun T, Li B, Shuai X, Chen Y, Li W, Cai Z, Qiao X, Hu S, Ma L. Performance and selectivity of lower-rim substituted calix[4]arene as a stationary phase for capillary gas chromatography. RSC Adv 2019; 9:21207-21214. [PMID: 35521345 PMCID: PMC9065984 DOI: 10.1039/c9ra03004b] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2019] [Accepted: 07/02/2019] [Indexed: 11/21/2022] Open
Abstract
This work presents the investigation of p-tert-butyl(tetradecyloxy)calix[4]arene (C4A-C10) as stationary phase for capillary gas chromatographic (GC) separations. The statically-coated C4A-C10 capillary column showed weak polarity and column efficiency of 2566 plates per m determined by n-dodecane at 120 °C. Impressively, the C4A-C10 column exhibited extremely high resolving capability for a wide range of analytes from nonpolar to polar, including n-alkanes, esters, ketones, aldehydes, alcohols and bromoalkanes. Most importantly, the C4A-C10 column exhibited an excellent separation performance for positional, structural and cis-/trans-isomers. Among them, the column displayed advantageous resolving capability over the commercial polysiloxane stationary phase for aromatic amine isomers. Moreover, the C4A-C10 column showed good column repeatability with RSD values below 0.06% for run-to-run, 0.12–0.27% for day-to-day and 2.8–5.3% for column-to-column. This work presents the investigation of p-tert-butyl(tetradecyloxy)calix[4]arene (C4A-C10) as stationary phase for capillary gas chromatographic (GC) separations.![]()
Collapse
Affiliation(s)
- Tao Sun
- College of Chemistry and Chemical Engineering
- Henan Key Laboratory of Function-Oriented Porous Materials
- Luoyang Normal University
- Luoyang 471934
- P. R. China
| | - Bin Li
- Hebei Key Laboratory of Heterocyclic Compounds
- Handan University
- Handan 056005
- China
| | - Xiaomin Shuai
- School of Petrochemical Engineering
- Shenyang University of Technology
- Liaoyang
- P. R. China
| | - Yujie Chen
- College of Chemistry and Chemical Engineering
- Henan Key Laboratory of Function-Oriented Porous Materials
- Luoyang Normal University
- Luoyang 471934
- P. R. China
| | - WeiWei Li
- College of Chemistry and Chemical Engineering
- Henan Key Laboratory of Function-Oriented Porous Materials
- Luoyang Normal University
- Luoyang 471934
- P. R. China
| | - Zhiqiang Cai
- School of Petrochemical Engineering
- Shenyang University of Technology
- Liaoyang
- P. R. China
| | - Xiaoguang Qiao
- College of Chemistry and Chemical Engineering
- Henan Key Laboratory of Function-Oriented Porous Materials
- Luoyang Normal University
- Luoyang 471934
- P. R. China
| | - Shaoqiang Hu
- College of Chemistry and Chemical Engineering
- Henan Key Laboratory of Function-Oriented Porous Materials
- Luoyang Normal University
- Luoyang 471934
- P. R. China
| | - Lufang Ma
- College of Chemistry and Chemical Engineering
- Henan Key Laboratory of Function-Oriented Porous Materials
- Luoyang Normal University
- Luoyang 471934
- P. R. China
| |
Collapse
|
37
|
Fang C, Du H, Jia W, Xu Y. Compositional Differences and Similarities between Typical Chinese Baijiu and Western Liquor as Revealed by Mass Spectrometry-Based Metabolomics. Metabolites 2018; 9:E2. [PMID: 30577624 PMCID: PMC6358772 DOI: 10.3390/metabo9010002] [Citation(s) in RCA: 47] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2018] [Revised: 12/04/2018] [Accepted: 12/12/2018] [Indexed: 12/26/2022] Open
Abstract
Distilled liquors are important products, both culturally and economically. Chemically, as a complex mixture, distilled liquor comprises various chemical compounds in addition to ethanol. However, the chemical components of distilled liquors are still insufficiently understood and compositional differences and similarities of distilled liquors from different cultures have never been compared. For the first time, both volatile organic compounds (VOCs) and non-VOCs in distilled liquors were profiled using mass spectrometry-based metabolomic approaches. A total of 879 VOCs and 268 non-VOCs were detected in 24 distilled liquors including six typical Chinese baijiu and 18 typical Western liquors. Principal component analysis and a correlation network revealed important insights into the compositional differences and similarities of the distilled liquors that were assessed. Ethyl esters, a few benzene derivatives, and alcohols were shared by most distilled liquors assessed, suggesting their important contribution to the common flavor and mouthfeel of distilled liquors. Sugars and esters formed by fatty alcohol differ significantly between the assessed Chinese baijiu and Western liquors, and are potential marker compounds that could be used for their discrimination. Factors contributing to the differences in chemical composition are proposed. Our results improve our understanding of the chemical components of distilled liquors, which may contribute to more rigorous quality control of alcoholic beverages.
Collapse
Affiliation(s)
- Cheng Fang
- State Key Laboratory of Food Science and Technology, School of Biotechnology, Jiangnan University, Wuxi 214122, China.
| | - Hai Du
- State Key Laboratory of Food Science and Technology, School of Biotechnology, Jiangnan University, Wuxi 214122, China.
| | - Wei Jia
- University of Hawaii Cancer Center, Honolulu, HI 96813, USA.
| | - Yan Xu
- State Key Laboratory of Food Science and Technology, School of Biotechnology, Jiangnan University, Wuxi 214122, China.
| |
Collapse
|
38
|
Beale DJ, Pinu FR, Kouremenos KA, Poojary MM, Narayana VK, Boughton BA, Kanojia K, Dayalan S, Jones OAH, Dias DA. Review of recent developments in GC-MS approaches to metabolomics-based research. Metabolomics 2018; 14:152. [PMID: 30830421 DOI: 10.1007/s11306-018-1449-2] [Citation(s) in RCA: 269] [Impact Index Per Article: 38.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/21/2017] [Accepted: 11/08/2018] [Indexed: 12/19/2022]
Abstract
BACKGROUND Metabolomics aims to identify the changes in endogenous metabolites of biological systems in response to intrinsic and extrinsic factors. This is accomplished through untargeted, semi-targeted and targeted based approaches. Untargeted and semi-targeted methods are typically applied in hypothesis-generating investigations (aimed at measuring as many metabolites as possible), while targeted approaches analyze a relatively smaller subset of biochemically important and relevant metabolites. Regardless of approach, it is well recognized amongst the metabolomics community that gas chromatography-mass spectrometry (GC-MS) is one of the most efficient, reproducible and well used analytical platforms for metabolomics research. This is due to the robust, reproducible and selective nature of the technique, as well as the large number of well-established libraries of both commercial and 'in house' metabolite databases available. AIM OF REVIEW This review provides an overview of developments in GC-MS based metabolomics applications, with a focus on sample preparation and preservation techniques. A number of chemical derivatization (in-time, in-liner, offline and microwave assisted) techniques are also discussed. Electron impact ionization and a summary of alternate mass analyzers are highlighted, along with a number of recently reported new GC columns suited for metabolomics. Lastly, multidimensional GC-MS and its application in environmental and biomedical research is presented, along with the importance of bioinformatics. KEY SCIENTIFIC CONCEPTS OF REVIEW The purpose of this review is to both highlight and provide an update on GC-MS analytical techniques that are common in metabolomics studies. Specific emphasis is given to the key steps within the GC-MS workflow that those new to this field need to be aware of and the common pitfalls that should be looked out for when starting in this area.
Collapse
Affiliation(s)
- David J Beale
- Land and Water, Commonwealth Scientific & Industrial Research Organization (CSIRO), P.O. Box 2583, Brisbane, QLD, 4001, Australia.
| | - Farhana R Pinu
- The New Zealand Institute for Plant & Food Research Limited, Private Bag 92169, Auckland, 1142, New Zealand
| | - Konstantinos A Kouremenos
- Metabolomics Australia, Bio21 Molecular Science and Biotechnology Institute, The University of Melbourne, Parkville, 3010, Australia
- Trajan Scientific and Medical, 7 Argent Pl, Ringwood, 3134, Australia
| | - Mahesha M Poojary
- Chemistry Section, School of Science and Technology, University of Camerino, via S. Agostino 1, 62032, Camerino, Italy
- Department of Food Science, University of Copenhagen, Rolighedsvej 26, 1958, Frederiksberg C, Denmark
| | - Vinod K Narayana
- Metabolomics Australia, Bio21 Molecular Science and Biotechnology Institute, The University of Melbourne, Parkville, 3010, Australia
| | - Berin A Boughton
- Metabolomics Australia, School of BioSciences, The University of Melbourne, Parkville, 3010, Australia
| | - Komal Kanojia
- Metabolomics Australia, Bio21 Molecular Science and Biotechnology Institute, The University of Melbourne, Parkville, 3010, Australia
| | - Saravanan Dayalan
- Metabolomics Australia, Bio21 Molecular Science and Biotechnology Institute, The University of Melbourne, Parkville, 3010, Australia
| | - Oliver A H Jones
- Australian Centre for Research on Separation Science (ACROSS), School of Science, RMIT University, GPO Box 2476, Melbourne, 3001, Australia
| | - Daniel A Dias
- School of Health and Biomedical Sciences, Discipline of Laboratory Medicine, RMIT University, PO Box 71, Bundoora, 3083, Australia.
| |
Collapse
|
39
|
Torbati M, Mohebbi A, Farajzadeh MA, Afshar Mogaddam MR. Simultaneous derivatization and air–assisted liquid–liquid microextraction based on solidification of lighter than water deep eutectic solvent followed by gas chromatography–mass spectrometry: An efficient and rapid method for trace analysis of aromatic amines in aqueous samples. Anal Chim Acta 2018; 1032:48-55. [DOI: 10.1016/j.aca.2018.06.025] [Citation(s) in RCA: 48] [Impact Index Per Article: 6.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 04/24/2018] [Accepted: 06/08/2018] [Indexed: 01/10/2023]
|
40
|
Havlikova M, Cabala R, Pacakova V, Bursova M, Bosakova Z. Critical evaluation of microextraction pretreatment techniques - Part 1: Single drop and sorbent-based techniques. J Sep Sci 2018; 42:273-284. [DOI: 10.1002/jssc.201800902] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2018] [Revised: 10/02/2018] [Accepted: 10/02/2018] [Indexed: 12/16/2022]
Affiliation(s)
- Martina Havlikova
- Faculty of Science; Department of Analytical Chemistry; Charles University; Prague 2 Czech Republic
| | - Radomir Cabala
- Faculty of Science; Department of Analytical Chemistry; Charles University; Prague 2 Czech Republic
- Toxicology Department; Institute of Forensic Medicine and Toxicology; General University Hospital in Prague and 1st Faculty of Medicine of Charles University; Prague 2 Czech Republic
| | - Vera Pacakova
- Faculty of Science; Department of Analytical Chemistry; Charles University; Prague 2 Czech Republic
| | - Miroslava Bursova
- Faculty of Science; Department of Analytical Chemistry; Charles University; Prague 2 Czech Republic
- Toxicology Department; Institute of Forensic Medicine and Toxicology; General University Hospital in Prague and 1st Faculty of Medicine of Charles University; Prague 2 Czech Republic
| | - Zuzana Bosakova
- Faculty of Science; Department of Analytical Chemistry; Charles University; Prague 2 Czech Republic
| |
Collapse
|
41
|
Wang S, Cheng Y, Chen M, Jiang K. Differentiation of isomeric haloanilines by tosylation in combination with electrospray ionization mass spectrometry. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2018; 24:337-343. [PMID: 29436862 DOI: 10.1177/1469066718757587] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Differentiation of the isomeric haloanilines still remains a challenging and necessary analytic task due to their identical retention time in chromatography and similar mass spectra. In this work, p-tosylation of haloanilines by reaction of haloanilines with p-toluenesulfonyl chloride resulted in the corresponding N-tosyl haloanilines. Fragmentation of protonated N-tosyl haloanilines in electrospray ionization tandem mass spectrometry (ESI-MS/MS) mainly resulted in tosyl cation, haloaniline radical cation, and halohydroxyaniline radical cation. The MS/MS of the three group isomeric derivatives showed significant difference in abundance distribution of these product ions, respectively. Theoretical calculations showed that the stability of the ion-neutral complex (INC) is a key factor influencing the relative intensity of the product ions. The three group isomeric derivatives were also separated by high performance liquid chromatograph (HPLC) at conventional conditions. p-Tosylation combined tandem MS (or HPLC) technique were carried out to realize the differentiation of isomeric haloanilines.
Collapse
Affiliation(s)
- Shanshan Wang
- 1 State Key Laboratory Breeding Base for Zhejiang Sustainable Pest and Disease Control, Key Laboratory for Pesticide Residue Detection of Ministry of Agriculture, Institute of Quality and Standard for Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
- 2 Key Laboratory of Organosilicon Chemistry and Material Technology, Hangzhou Normal University, Hangzhou, China
| | - Yuanyuan Cheng
- 1 State Key Laboratory Breeding Base for Zhejiang Sustainable Pest and Disease Control, Key Laboratory for Pesticide Residue Detection of Ministry of Agriculture, Institute of Quality and Standard for Agro-products, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
| | - Mengmeng Chen
- 2 Key Laboratory of Organosilicon Chemistry and Material Technology, Hangzhou Normal University, Hangzhou, China
| | - Kezhi Jiang
- 2 Key Laboratory of Organosilicon Chemistry and Material Technology, Hangzhou Normal University, Hangzhou, China
| |
Collapse
|
42
|
Lee J, Lee Y, Nam TG, Jang HW. Dispersive liquid-liquid microextraction with in situ derivatization coupled with gas chromatography and mass spectrometry for the determination of 4-methylimidazole in red ginseng products containing caramel colors. J Sep Sci 2018; 41:3415-3423. [PMID: 30022588 DOI: 10.1002/jssc.201800559] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Revised: 07/07/2018] [Accepted: 07/15/2018] [Indexed: 01/24/2023]
Abstract
A rapid analytical method was developed for the determination of 4-methylimidazole from red ginseng products containing caramel colors by using dispersive liquid-liquid microextraction with in situ derivatization followed by gas chromatography with mass spectrometry. Chloroform and acetonitrile were selected as the extraction and dispersive solvents, and based on the extraction efficiency, their optimum volumes were 200 and 100 μL, respectively. The optimum volumes of the derivatizing agent (isobutyl chloroformate) and catalyst (pyridine), pH, and concentration of NaCl in the sample solution were determined to be 25 and 100 μL, pH 7.6, and 0% w/v, respectively. Validation of the optimized method showed good linearity (R2 > 0.999), accuracy (≥89.86%), intra- (≤6.70%) and interday (≤4.17%) repeatability, limit of detection (0.96 μg/L), and limit of quantification (5.79 μg/L). The validated method was applied to quantify 4-methylimidazole in red ginseng juices and concentrates, 4-methylimidazole was only found in red ginseng juices containing caramel colorant (42.91-2863.4 μg/L) and detected in red ginseng concentrates containing >1% caramel colorant.
Collapse
Affiliation(s)
- Jangho Lee
- 245, Nongsaengmyeong-ro, Korea Food Research Institute, Wanju-gun, Jeollabuk-do, Republic of Korea.,Department of Food Biotechnology, 217, Gajeong-ro, Korea University of Science and Technology, Daejeon, Republic of Korea
| | - Yunyeol Lee
- 245, Nongsaengmyeong-ro, Korea Food Research Institute, Wanju-gun, Jeollabuk-do, Republic of Korea
| | - Tae Gyu Nam
- 245, Nongsaengmyeong-ro, Korea Food Research Institute, Wanju-gun, Jeollabuk-do, Republic of Korea
| | - Hae Won Jang
- 245, Nongsaengmyeong-ro, Korea Food Research Institute, Wanju-gun, Jeollabuk-do, Republic of Korea
| |
Collapse
|
43
|
Bazregar M, Rajabi M, Yamini Y, Asghari A. Filter-based emulsification microextraction as an efficient method for the determination of chlorophenols by gas chromatography. J Sep Sci 2018; 41:3097-3104. [DOI: 10.1002/jssc.201800233] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2018] [Revised: 05/21/2018] [Accepted: 05/22/2018] [Indexed: 12/31/2022]
Affiliation(s)
| | - Maryam Rajabi
- Department of Chemistry; Semnan University; Semnan Iran
| | - Yadollah Yamini
- Department of Chemistry; Tarbiat Modares University; Tehran Iran
| | | |
Collapse
|
44
|
|
45
|
Kočová Vlčková H, Pilařová V, Svobodová P, Plíšek J, Švec F, Nováková L. Current state of bioanalytical chromatography in clinical analysis. Analyst 2018; 143:1305-1325. [DOI: 10.1039/c7an01807j] [Citation(s) in RCA: 34] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Chromatographic methods have become popular in clinical analysis in both routine and research laboratories.
Collapse
Affiliation(s)
- H. Kočová Vlčková
- Deparment of Analytical Chemistry
- Faculty of Pharmacy in Hradec Králové
- Charles University
- Hradec Králové
- Czech Republic
| | - V. Pilařová
- Deparment of Analytical Chemistry
- Faculty of Pharmacy in Hradec Králové
- Charles University
- Hradec Králové
- Czech Republic
| | - P. Svobodová
- Deparment of Analytical Chemistry
- Faculty of Pharmacy in Hradec Králové
- Charles University
- Hradec Králové
- Czech Republic
| | - J. Plíšek
- Deparment of Analytical Chemistry
- Faculty of Pharmacy in Hradec Králové
- Charles University
- Hradec Králové
- Czech Republic
| | - F. Švec
- Deparment of Analytical Chemistry
- Faculty of Pharmacy in Hradec Králové
- Charles University
- Hradec Králové
- Czech Republic
| | - L. Nováková
- Deparment of Analytical Chemistry
- Faculty of Pharmacy in Hradec Králové
- Charles University
- Hradec Králové
- Czech Republic
| |
Collapse
|
46
|
Chen Z, Li G, Zhang Z. Miniaturized Thermal-Assisted Purge-and-Trap Technique Coupling with Surface-Enhanced Raman Scattering for Trace Analysis of Complex Samples. Anal Chem 2017; 89:9593-9600. [DOI: 10.1021/acs.analchem.7b02912] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Zhengyi Chen
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Gongke Li
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| | - Zhuomin Zhang
- School of Chemistry, Sun Yat-sen University, Guangzhou 510275, China
| |
Collapse
|
47
|
Determination of aliphatic amines in food by on-fiber derivatization solid-phase microextraction with a novel zeolitic imidazolate framework 8-coated stainless steel fiber. Talanta 2017; 165:326-331. [DOI: 10.1016/j.talanta.2016.12.075] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2016] [Revised: 12/22/2016] [Accepted: 12/26/2016] [Indexed: 11/17/2022]
|
48
|
Alsharif AMA, Tan GH, Choo YM, Lawal A. Efficiency of Hollow Fiber Liquid-Phase Microextraction Chromatography Methods in the Separation of Organic Compounds: A Review. J Chromatogr Sci 2016; 55:378-391. [DOI: 10.1093/chromsci/bmw188] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2016] [Accepted: 11/10/2016] [Indexed: 11/13/2022]
Affiliation(s)
- Ali Mohamed Ali Alsharif
- Department of Chemistry, Faculty of Science, University of Malaya, 50603 Kuala Lumpur, Malaysia
- Arab Centre for Desertification and Development of Saharian Societies, Murzuk, Libya
| | - Guan-Huat Tan
- Department of Chemistry, Faculty of Science, University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Yeun-Mun Choo
- Department of Chemistry, Faculty of Science, University of Malaya, 50603 Kuala Lumpur, Malaysia
| | - Abubakar Lawal
- Department of Chemistry, Faculty of Science, University of Malaya, 50603 Kuala Lumpur, Malaysia
- Department of Pure and Industrial Chemistry, Umaru Musa Yar'adua University Katsina, Nigeria
| |
Collapse
|
49
|
Li J, Qi HY, Wang YB, Su Q, Wu S, Wu L. Hollow fiber-stir bar sorptive extraction and microwave assisted derivatization of amino acids in biological matrices. J Chromatogr A 2016; 1474:32-39. [PMID: 27836229 DOI: 10.1016/j.chroma.2016.10.079] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Revised: 10/29/2016] [Accepted: 10/31/2016] [Indexed: 01/23/2023]
Abstract
A kind of solid phase microextraction configuration combining the principles of hollow fiber solid phase microextraction (HF-SPME) and stir bar sorptive extraction (SBSE) is presented. The main feature of HF-SBSE is the use of microporous hollow fiber acting as the carrier and filter, while a thin stainless steel wire and silica microspheres in the lumen of hollow fiber respectively acting as the magnetic stirrer and the dispersed sorbents for the collection and extraction of the target analytes, thus affording extraction process like SBSE. Moreover, the prepared hollow fiber stir bar was applied to direct microextraction and microwave assisted derivatization with N,O-Bis(trimethylsilyl)trifluroacetamide (BSTFA) of four amino acids in rats' urine and cerebrospinal fluid followed by gas chromatography mass spectrometric analysis. The limits of detection for four amino acids were found to be in the range of 0.0003-0.017μgmL-1, and all the analytes did not exhibit any lack of fit. The extraction recoveries using HF-SBSE techniques ranged from 71.8% to 102.3%. The results indicated that hollow fiber stir bar sorptive extraction was a promising technique for the enrichment and direct derivatization of analytes extracted from biological matrices without sample clean-up.
Collapse
Affiliation(s)
- Jia Li
- Chemical Engineering Institute, Key Laboratory of Environmental Friendly Composite Materials and Biomass Utilization, Northwest University for Nationalities, Lanzhou 730000, China.
| | - Huan-Yang Qi
- Xiamen Medicine Research Institute, Xiamen 361008, China
| | - Yan-Bin Wang
- Chemical Engineering Institute, Key Laboratory of Environmental Friendly Composite Materials and Biomass Utilization, Northwest University for Nationalities, Lanzhou 730000, China
| | - Qiong Su
- Chemical Engineering Institute, Key Laboratory of Environmental Friendly Composite Materials and Biomass Utilization, Northwest University for Nationalities, Lanzhou 730000, China
| | - Shang Wu
- Chemical Engineering Institute, Key Laboratory of Environmental Friendly Composite Materials and Biomass Utilization, Northwest University for Nationalities, Lanzhou 730000, China
| | - Lan Wu
- Chemical Engineering Institute, Key Laboratory of Environmental Friendly Composite Materials and Biomass Utilization, Northwest University for Nationalities, Lanzhou 730000, China.
| |
Collapse
|
50
|
Holmgren KH, Gustafsson T, Östin A. Screening of nerve agent markers with hollow fiber-chemosorption of phosphonic acids. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1033-1034:97-105. [DOI: 10.1016/j.jchromb.2016.08.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 08/08/2016] [Accepted: 08/12/2016] [Indexed: 11/28/2022]
|