1
|
Fernández Blanco A, Moreno Y, García-Hernández J, Hernández M. A Photonic Immunosensor Detection Method for Viable and Non-Viable E. coli in Water Samples. Microorganisms 2024; 12:1328. [PMID: 39065096 PMCID: PMC11278787 DOI: 10.3390/microorganisms12071328] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2024] [Revised: 06/17/2024] [Accepted: 06/21/2024] [Indexed: 07/28/2024] Open
Abstract
Detection and enumeration of coliform bacteria using traditional methods and current molecular techniques against E. coli usually involve long processes with less sensitivity and specificity to distinguish between viable and non-viable bacteria for microbiological water analysis. This approach involves developing and validating an immunosensor comprising ring resonators functionalized with specific antibodies surrounded by a network of microchannels as an alternative method for detecting and indirectly enumerating Escherichia coli in samples of water for consumption. Different ELISA assays were conducted to characterize monoclonal and polyclonal antibodies selected as detection probes for specific B-galactosidase enzymes and membrane LPS antigens of E. coli. An immobilization control study was performed on silicon nitride surfaces used in the immunosensor, immobilized with the selected antibodies from the ELISA assays. The specificity of this method was confirmed by detecting as few as 10 CFU/mL of E. coli from viable and non-viable target bacteria after applying various disinfection methods to water samples intended for human consumption. The 100% detection rate and a 100 CFU/mL Limit of Quantification of the proposed method were validated through a comprehensive assessment of the immunosensor-coupled microfluidic system, involving at least 50 replicates with a concentration range of 10 to 106 CFU/mL of the target bacteria and 50 real samples contaminated with and without disinfection treatment. The correlation coefficient of around one calculated for each calibration curve obtained from the results demonstrated sensitive and rapid detection capabilities suitable for application in water resources intended for human consumption within the food industry. The biosensor was shown to provide results in less than 4 h, allowing for rapid identification of microbial contamination crucial for ensuring water monitoring related to food safety or environmental diagnosis and allowing for timely interventions to mitigate contamination risks. Indeed, the achieved setup facilitates the in situ execution of laboratory processes, allowing for the detection of both viable and non-viable bacteria, and it implies future developments of simultaneous detection of pathogens in the same contaminated sample.
Collapse
Affiliation(s)
| | - Yolanda Moreno
- Institute of Water and Environmental Engineering, Universitat Politècnica de València, 46022 Valencia, Spain
| | - Jorge García-Hernández
- Advanced Center for Food Microbiology, Biotechnology Department, Universitat Politècnica de València, 46022 Valencia, Spain; (J.G.-H.); (M.H.)
| | - Manuel Hernández
- Advanced Center for Food Microbiology, Biotechnology Department, Universitat Politècnica de València, 46022 Valencia, Spain; (J.G.-H.); (M.H.)
| |
Collapse
|
2
|
Sol–Gel Synthesis and Electrochemical Sensing Properties of Brownmillerite Calcium Ferrite–Ca2Fe2O5 Nanoparticles. J Inorg Organomet Polym Mater 2022. [DOI: 10.1007/s10904-022-02397-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
3
|
Park S, Park K, Cho H, Kwon J, Kim KS, Yang H. Wash-Free Amperometric Escherichia coli Detection via Rapid and Specific Proteolytic Cleavage by Its Outer Membrane OmpT. Anal Chem 2022; 94:4756-4762. [PMID: 35143182 DOI: 10.1021/acs.analchem.1c05299] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Various methods have been developed for the detection of Escherichia coli (E. coli); however, they are complex and time-consuming. OmpT─a cell membrane endopeptidase of E. coli─strongly embedded in the outer membrane of only E. coli, exposed to external solutions, with high proteolytic activity, could be a suitable target molecule for the rapid and straightforward detection of E. coli. Herein, a wash-free, sensitive, and selective amperometric method for E. coli detection, based on rapid and specific proteolytic cleavage by OmpT, has been reported. The method involved (i) rapid proteolytic cleavage of consecutive amino acids, after cleavage by OmpT, linked to an electrochemical species (4-aminophenol, AP), by leucine aminopeptidase (LAP, an exopeptidase), (ii) affinity binding of E. coli on an electrode, and (iii) electrochemical-enzymatic (EN) redox cycling. OmpT cleaved the intermediate peptide bond of a peptide substrate containing alanine-arginine-arginine-leucine-AP (-A-R-R-L-AP), forming R-L-AP, followed by the cleavage of two peptide bonds of R-L-AP sequentially by LAP, to liberate an electroactive AP. Affinity binding and EN redox cycling, in addition to rapid proteolytic cleavage by OmpT and LAP, enabled high electrochemical signal amplification. Two-sequential-cleavage was employed for the first time in protease-based detection. The calculated detection limit for E. coli cells in tap water (approximately 103 CFU/mL after 1 h incubation) was lower than those obtained without affinity binding and EN redox cycling. The detection method was highly selective to E. coli as OmpT is present in only E. coli. High sensitivity, selectivity, and the absence of wash steps make the developed detection method practically promising.
Collapse
Affiliation(s)
- Seonhwa Park
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea
| | - Kiryeon Park
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea
| | - Hyejin Cho
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea
| | - Jungwook Kwon
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea
| | - Kwang-Sun Kim
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea
| | - Haesik Yang
- Department of Chemistry and Chemistry Institute for Functional Materials, Pusan National University, Busan 46241, Korea
| |
Collapse
|
4
|
Cai J, Yishun H, Zhang W. The single-tube quantitative rapid detection of coliform bacteria based on enzyme-specific technology. Chem Commun (Camb) 2021; 57:5270-5273. [PMID: 33908984 DOI: 10.1039/d1cc01109j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
To detect coliform bacteria (CB) with simplicity and portability, a novel, single-tube quantitative rapid detection method was developed based on CB-specific enzymatic technology. This technology involved a simple multi-channel spectrometer which could detect 7 cfu mL-1 CB specifically, and the approach was applied to various food and water samples.
Collapse
Affiliation(s)
- Jinzhong Cai
- College of Environment and Public Health, Xiamen Huaxia University, Xiamen 361024, Fujian, China. and Key Laboratory of Environmental Monitoring in Fujian Colleges and Universities, Xiamen, 361024, Fujian, China
| | - Huang Yishun
- College of Environment and Public Health, Xiamen Huaxia University, Xiamen 361024, Fujian, China. and Institute of Analytical Technology and Smart Instruments, Xiamen Huaxia University, Xiamen, 361024, Fujian, China
| | - Weiyun Zhang
- Department of Pharmacy, Xiamen Medical College, Xiamen 361023, Fujian, China
| |
Collapse
|
5
|
Zhang H, Mou J, Ding J, Qin W. Magneto-controlled potentiometric assay for E. coli based on cleavage of peptide by outer-membrane protease T. Electrochim Acta 2021. [DOI: 10.1016/j.electacta.2021.138408] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/11/2023]
|
6
|
Okpara EC, Nde SC, Fayemi OE, Ebenso EE. Electrochemical Characterization and Detection of Lead in Water Using SPCE Modified with BiONPs/PANI. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:1294. [PMID: 34069149 PMCID: PMC8156766 DOI: 10.3390/nano11051294] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 05/02/2021] [Accepted: 05/04/2021] [Indexed: 11/17/2022]
Abstract
The need for constant assessment of river water qualities for both aquatic and other biological survival has emerged a top priority, due to increasing exposure to industrial pollutants. A disposable screen print carbon electrode was modified with a conductive polymer (PANI) and Zn and/or Cu oxides NPs, obtained through bioreduction in citrus peel extracts (lemon and orange), for ultra-sensitive detection of PB2+, in the Crocodile River water sample. The synthesized materials were characterized with Fourier-transform infra-red spectroscopy (FTIR), ultra-violet visible spectroscopy (UV-Vis), and scanning electron microscopy (SEM). The SPC-modified electrodes designated as SPCE/LPE/BiONPs/PANI and SPCE/OPE/BiONPs/PANI were characterized using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) and eventually deployed in the electrochemical detection of PB2+ in water using square wave voltammetry (SWV) technique. The electrochemical responses of the modified electrodes for both CV and EIS in 0.1 M HCl demonstrated enhanced performance relative to the bare SPCE. A detection and quantification limit of 0.494 ppb and 1.647 were obtained at SPCE/LPE/BiONPs/PANI, respectively, while a detection and quantification limit of 2.79 ppb and 8.91 ppb, respectively, were derived from SPCE/OPE/BiONPs/PANI. The relative standard deviations (RSD) for SPC electrode at a 6.04 µM PB2+ analyte concentration was 4.76% and 0.98% at SPCE/LPE/BiONPs/PANI and SPCE/LPE/BiONPs/PANI, respectively. The effect of copper, zinc, iron, cobalt, nickel, and magnesium on the stripping peaks of PB2+ at SPCE/OPE/BiONPs/PANI, showed no significant change except for cobalt, with about 17.67% peak current drop. The sensors were assessed for possible determination of PB2+ in spiked river water samples. The average percentage recovery and RSD calculated were 94.25% and 3.74% (n = 3) at SPCE/LPE/BiONPs/PANI and, 96.70% and 3.71% (n = 3) at SPCE/OPE/BiONPs/PANI, respectively. Therefore, the fabricated sensor material could be used for environmental assessment of this highly toxic heavy metal in the aquatic system.
Collapse
Affiliation(s)
- Enyioma C. Okpara
- Department of Chemistry, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Private Bag X2046, Mmabatho 2735, South Africa;
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Private Bag X2046, Mmabatho 2735, South Africa
| | - Samuel Che Nde
- Department of Geography and Environmental Sciences, North-West University, Mafikeng Campus, Mmabatho 2735, South Africa;
| | - Omolola E. Fayemi
- Department of Chemistry, School of Physical and Chemical Sciences, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Private Bag X2046, Mmabatho 2735, South Africa;
- Material Science Innovation and Modelling (MaSIM) Research Focus Area, Faculty of Natural and Agricultural Sciences, North-West University (Mafikeng Campus), Private Bag X2046, Mmabatho 2735, South Africa
| | - Eno E. Ebenso
- Institute of Nanotechnology and Water Sustainability, College of Science, Engineering and Technology, University of South Africa, Johannesburg 1710, South Africa;
| |
Collapse
|
7
|
Poulouxi S, Prodromidis MI. Indirect determination of Escherichia coli based on β-D-glucuronidase activity and the voltammetric oxidation of phenolphthalein at graphite screen-printed electrodes. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114752] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
8
|
Holcomb DA, Stewart JR. Microbial Indicators of Fecal Pollution: Recent Progress and Challenges in Assessing Water Quality. Curr Environ Health Rep 2020; 7:311-324. [PMID: 32542574 PMCID: PMC7458903 DOI: 10.1007/s40572-020-00278-1] [Citation(s) in RCA: 61] [Impact Index Per Article: 12.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
PURPOSE OF REVIEW Fecal contamination of water is a major public health concern. This review summarizes recent developments and advancements in water quality indicators of fecal contamination. RECENT FINDINGS This review highlights a number of trends. First, fecal indicators continue to be a valuable tool to assess water quality and have expanded to include indicators able to detect sources of fecal contamination in water. Second, molecular methods, particularly PCR-based methods, have advanced considerably in their selected targets and rigor, but have added complexity that may prohibit adoption for routine monitoring activities at this time. Third, risk modeling is beginning to better connect indicators and human health risks, with the accuracy of assessments currently tied to the timing and conditions where risk is measured. Research has advanced although challenges remain for the effective use of both traditional and alternative fecal indicators for risk characterization, source attribution and apportionment, and impact evaluation.
Collapse
Affiliation(s)
- David A Holcomb
- Department of Epidemiology, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, 135 Dauer Dr., Chapel Hill, NC, 27599-7435, USA
| | - Jill R Stewart
- Department of Environmental Sciences and Engineering, Gillings School of Global Public Health, University of North Carolina at Chapel Hill, 135 Dauer Dr., Chapel Hill, NC, 27599-7431, USA.
| |
Collapse
|