1
|
Rad VF, Mohammadi M, Moradi AR. Morphometric effects of particulate air pollution on an optically trapped single red blood cell. Sci Rep 2025; 15:16068. [PMID: 40341733 PMCID: PMC12062408 DOI: 10.1038/s41598-025-00955-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2024] [Accepted: 05/02/2025] [Indexed: 05/11/2025] Open
Abstract
Particulate air pollution is associated with excess deaths and increases in hospital admissions because of cardiovascular and respiratory diseases. Several scientific studies and assessments have linked particulate pollution to a variety of health problems. In this paper, we provide a single cell in vitro analysis for the effect of the particles, which can enter into blood stream, on red blood cells (RBCs). The RBCs under experiment are incubated with [Formula: see text] particle as the most abundant air pollutants in big cities. The self-referencing digital holographic microscopy (DHM) in Gates' arrangement as a vibration-immune methodology is considered here for live visualization and quantitative analysis of the cells. DHM is a label-free and noninvasive method, therefore, suitable for quantitative and morphometric imaging of biological specimens in arbitrary time scales and at video rates. Single RBCs are immobilized by a blinking multiple optical trapping system integrated to the DHM system. Through post-process numerical reconstruction of the recorded digital holograms, the morphology changes of the pollution-exposed RBCs are tracked and expressed in terms of volume and several statistical morphometry parameters.
Collapse
Affiliation(s)
- Vahideh Farzam Rad
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), 45137-66731, Zanjan, Iran
| | - Maryam Mohammadi
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), 45137-66731, Zanjan, Iran
- Biozentrum, University of Basel, Spitalstrasse 41, 4056, Basel, Switzerland
| | - Ali-Reza Moradi
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), 45137-66731, Zanjan, Iran.
- School of Quantum Physics and Matter, Institute for Research in Fundamental Sciences (IPM), 19395-5531, Tehran, Iran.
| |
Collapse
|
2
|
Abbasian V, Darafsheh A. A dataset of digital holograms of normal and thalassemic cells. Sci Data 2024; 11:3. [PMID: 38168104 PMCID: PMC10762191 DOI: 10.1038/s41597-023-02818-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2023] [Accepted: 12/04/2023] [Indexed: 01/05/2024] Open
Abstract
Digital holographic microscopy (DHM) is an intriguing medical diagnostic tool due to its label-free and quantitative nature, providing high-contrast images of phase samples. By capturing both intensity and phase information, DHM enables the numerical reconstruction of quantitative phase images. However, the lateral resolution is limited by the diffraction limit, which prompted the recent suggestion of microsphere-assisted DHM to enhance the DHM resolution straightforwardly. The use of such a technique as a medical diagnostic tool requires testing and validation of the proposed assays to prove their feasibility and viability. This paper publishes 760 and 609 microsphere-assisted DHM images of normal and thalassemic red blood cells obtained from a normal and thalassemic male individual, respectively.
Collapse
Affiliation(s)
- Vahid Abbasian
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO, 63110, USA.
- Imaging Science Program, McKelvey School of Engineering, Washington University in St. Louis, St. Louis, MO, 63130, USA.
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran.
| | - Arash Darafsheh
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO, 63110, USA
| |
Collapse
|
3
|
Abbasian V, Darafsheh A, Moradi AR. Simple high-resolution 3D microscopy by a dielectric microsphere: a proof of concept. OPTICS LETTERS 2023; 48:6216-6219. [PMID: 38039230 DOI: 10.1364/ol.502599] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 11/09/2023] [Indexed: 12/03/2023]
Abstract
We present a simple high-resolution approach for 3D and quantitative phase imaging (QPI). Our method makes the most of a glass microsphere (MS) for microscopy and a glass plate for lateral shearing self-referencing interferometry. The single MS serves all the functions of a microscope objective (MO) in digital holographic microscopy (DHM) while offering the advantages of compactness, lightness, and affordability. A proof-of-concept experiment is performed on a standard diffraction grating, and various effective parameters on the imaging performance are investigated. The results are validated by atomic force microscopy and Mirau-DHM, and 3D morphometric information of the sample under inspection is obtained. The technique is then applied for 3D quantitative measurement and visualization of a human red blood cell, proving the principle of our easy-to-implement and vibration-immune arrangement for high-contrast label-free QPI of biological samples, and its utility in cell morphology, identification, and classification.
Collapse
|
4
|
Jamali R, Rad VF, Razaghi M, Mohamadnia Z, Khorasani M, Moradi AR. Digital holographic microscopy of spiropyran-based dynamic materials. J Microsc 2023; 292:78-89. [PMID: 37694978 DOI: 10.1111/jmi.13222] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 08/30/2023] [Accepted: 08/30/2023] [Indexed: 09/12/2023]
Abstract
Spiropyran (SP)-based dynamic materials undergo structural changes in response to external stimuli. In this paper, we show that digital holographic microscopy (DHM) is an effective candidate for characterisation of SPs (embedded in polymer matrices) and for monitoring of their dynamical changes. The polymer matrices are polylactic acid (PLA) and poly(methyl methacrylate) (PMMA) films, which are decorated with SPs and immobilised on graphene quantum dots (GQDs). GQDs are modified by benzylamines prior to the loading of SP species because of the enhancement of hydrophobic characteristics. UV irradiation is used as the external stimulus and the dynamical changes of the samples before and after UV irradiation are measured. DHM is arranged on a novel self-referencing setup, which substantially reduces the sensitivity of DHM to environmental vibrations. Morphometric information for characterisation of the samples is obtained by analysis of the recorded digital holograms. The experimental results demonstrate the potential of the presented technique to serve as an alternative technique for surface measurement methodologies such as atomic force microscope and stylus profiler for surface characterisation of similar materials.
Collapse
Affiliation(s)
- Ramin Jamali
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran
| | - Vahideh Farzam Rad
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran
| | - Masoumeh Razaghi
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran
| | - Zahra Mohamadnia
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran
| | - Mojtaba Khorasani
- Department of Chemistry, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran
- Research Center for Basic Sciences & Modern Technologies (RBST), Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran
| | - Ali-Reza Moradi
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, Iran
- School of Nano Science, Institute for Research in Fundamental Sciences (IPM), Tehran, Iran
| |
Collapse
|
5
|
Bogue-Jimenez B, Trujillo C, Doblas A. Comprehensive tool for a phase compensation reconstruction method in digital holographic microscopy operating in non-telecentric regime. PLoS One 2023; 18:e0291103. [PMID: 37682849 PMCID: PMC10491004 DOI: 10.1371/journal.pone.0291103] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Accepted: 08/22/2023] [Indexed: 09/10/2023] Open
Abstract
Quantitative phase imaging (QPI) via Digital Holographic microscopy (DHM) has been widely applied in material and biological applications. The performance of DHM technologies relies heavily on computational reconstruction methods to provide accurate phase measurements. Among the optical configuration of the imaging system in DHM, imaging systems operating in a non-telecentric regime are the most common ones. Nonetheless, the spherical wavefront introduced by the non-telecentric DHM system must be compensated to provide undistorted phase measurements. The proposed reconstruction approach is based on previous work from Kemper's group. Here, we have reformulated the problem, reducing the number of required parameters needed for reconstructing phase images to the sensor pixel size and source wavelength. The developed computational algorithm can be divided into six main steps. In the first step, the selection of the +1-diffraction order in the hologram spectrum. The interference angle is obtained from the selected +1 order. Secondly, the curvature of the spherical wavefront distorting the sample's phase map is estimated by analyzing the size of the selected +1 order in the hologram's spectrum. The third and fourth steps are the spatial filtering of the +1 order and the compensation of the interference angle. The next step involves the estimation of the center of the spherical wavefront. An optional final optimization step has been included to fine-tune the estimated parameters and provide fully compensated phase images. Because the proper implementation of a framework is critical to achieve successful results, we have explicitly described the steps, including functions and toolboxes, required for reconstructing phase images without distortions. As a result, we have provided open-access codes and a user interface tool with minimum user input to reconstruct holograms recorded in a non-telecentric DHM system.
Collapse
Affiliation(s)
- Brian Bogue-Jimenez
- Department of Electrical and Computer Engineering, The University of Memphis, Memphis, Tennessee, United States of America
| | - Carlos Trujillo
- School of Applied Sciences and Engineering, Universidad EAFIT, Medellin, Colombia
| | - Ana Doblas
- Department of Electrical and Computer Engineering, The University of Memphis, Memphis, Tennessee, United States of America
| |
Collapse
|
6
|
Darafsheh A, Abbasian V. Dielectric microspheres enhance microscopy resolution mainly due to increasing the effective numerical aperture. LIGHT, SCIENCE & APPLICATIONS 2023; 12:22. [PMID: 36627286 PMCID: PMC9832005 DOI: 10.1038/s41377-022-01056-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 06/17/2023]
Abstract
Microsphere-assisted microscopy utilizing a microsphere in immediate proximity of the specimen boosts the imaging resolution mainly as a result of an increase in the effective numerical aperture of the system.
Collapse
Affiliation(s)
- Arash Darafsheh
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO, 63110, USA.
| | - Vahid Abbasian
- Department of Radiation Oncology, Washington University School of Medicine in St. Louis, St. Louis, MO, 63110, USA
| |
Collapse
|
7
|
Friedrich RP, Kappes M, Cicha I, Tietze R, Braun C, Schneider-Stock R, Nagy R, Alexiou C, Janko C. Optical Microscopy Systems for the Detection of Unlabeled Nanoparticles. Int J Nanomedicine 2022; 17:2139-2163. [PMID: 35599750 PMCID: PMC9115408 DOI: 10.2147/ijn.s355007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Accepted: 03/27/2022] [Indexed: 12/01/2022] Open
Abstract
Label-free detection of nanoparticles is essential for a thorough evaluation of their cellular effects. In particular, nanoparticles intended for medical applications must be carefully analyzed in terms of their interactions with cells, tissues, and organs. Since the labeling causes a strong change in the physicochemical properties and thus also alters the interactions of the particles with the surrounding tissue, the use of fluorescently labeled particles is inadequate to characterize the effects of unlabeled particles. Further, labeling may affect cellular uptake and biocompatibility of nanoparticles. Thus, label-free techniques have been recently developed and implemented to ensure a reliable characterization of nanoparticles. This review provides an overview of frequently used label-free visualization techniques and highlights recent studies on the development and usage of microscopy systems based on reflectance, darkfield, differential interference contrast, optical coherence, photothermal, holographic, photoacoustic, total internal reflection, surface plasmon resonance, Rayleigh light scattering, hyperspectral and reflectance structured illumination imaging. Using these imaging modalities, there is a strong enhancement in the reliability of experiments concerning cellular uptake and biocompatibility of nanoparticles, which is crucial for preclinical evaluations and future medical applications.
Collapse
Affiliation(s)
- Ralf P Friedrich
- Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine (SEON), Else Kröner-Fresenius-Stiftung Professorship, Universitätsklinikum Erlangen, Erlangen, 91054, Germany
| | - Mona Kappes
- Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine (SEON), Else Kröner-Fresenius-Stiftung Professorship, Universitätsklinikum Erlangen, Erlangen, 91054, Germany
| | - Iwona Cicha
- Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine (SEON), Else Kröner-Fresenius-Stiftung Professorship, Universitätsklinikum Erlangen, Erlangen, 91054, Germany
| | - Rainer Tietze
- Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine (SEON), Else Kröner-Fresenius-Stiftung Professorship, Universitätsklinikum Erlangen, Erlangen, 91054, Germany
| | - Christian Braun
- Institute of Legal Medicine, Ludwig-Maximilians-Universität München, München, 80336, Germany
| | - Regine Schneider-Stock
- Experimental Tumor Pathology, Institute of Pathology, University Hospital, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, 91054, Germany
| | - Roland Nagy
- Department Elektrotechnik-Elektronik-Informationstechnik (EEI), Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, 91058, Germany
| | - Christoph Alexiou
- Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine (SEON), Else Kröner-Fresenius-Stiftung Professorship, Universitätsklinikum Erlangen, Erlangen, 91054, Germany
| | - Christina Janko
- Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine (SEON), Else Kröner-Fresenius-Stiftung Professorship, Universitätsklinikum Erlangen, Erlangen, 91054, Germany
- Correspondence: Christina Janko, Department of Otorhinolaryngology, Head and Neck Surgery, Section of Experimental Oncology and Nanomedicine (SEON), Else Kröner-Fresenius-Stiftung Professorship, Universitätsklinikum Erlangen, Glückstrasse 10a, Erlangen, 91054, Germany, Tel +49 9131 85 33142, Fax +49 9131 85 34808, Email
| |
Collapse
|
8
|
Rezaei N, Aakhte M, Charsooghi M, Borzouei H, Akhlaghi EA. 3D particle tracking using transport of intensity equation (TIE). OPTICS EXPRESS 2022; 30:2659-2667. [PMID: 35209401 DOI: 10.1364/oe.441265] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Accepted: 12/23/2021] [Indexed: 06/14/2023]
Abstract
This article presents a simple and high-speed approach for tracking colloidal spheres in three dimensions. The method uses the curvature of the wavefront as determined by the transport of intensity equation (TIE) technique. Due to the fact that the TIE is applicable under partially coherent light, our technique is fully compatible with standard bright field microscopes, requiring no demanding environmental stability requirements or restrictions on the noise produced by related laser speckles. The method was validated experimentally to determine the sedimentation and diffusion coefficients of two different sizes of microspheres, 20 and 3 microns. The 3D position of the microspheres was calculated with an accuracy greater than 350 nm. Moreover, we examined the calculated 3D positions to determine the parameters of the microsphere interaction with its surrounding media, such as the sedimentation and diffusion coefficients. The results show that the measured sedimentation and diffusion of the microspheres have a good agreement with predicted values of about 2% and 10%, respectively, demonstrating the robustness of our proposed method.
Collapse
|
9
|
Rad VF, Babaei-Ghazvini A, Jamali R, Shahabi-Ghahfarrokhi I, Moradi AR. Digital holographic microscopy for real-time investigation of 3D microstructural dynamics of starch-kefiran-based nanocomposite. APPLIED OPTICS 2021; 60:4706-4715. [PMID: 34143028 DOI: 10.1364/ao.423075] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Accepted: 05/04/2021] [Indexed: 06/12/2023]
Abstract
Investigating real-time phenomena in bio-polymers has received much attention because of their increasing demands in polymer substitution. The 3D morphometry of polymer surfaces may be very impactful in such studies. Here, digital holographic microscopy (DHM) is applied for quantitative measurement of the rare morphological changes of UV-A and UV-C exposed nanocomposites during their incubation with excess water. By reconstructing the recorded successive digital holograms, the time evolution of the swelled regions of the samples is derived. Our results clearly show that the higher water swelling of UV-A irradiated starch/kefiran/ZnO may be attributed to its higher hydrophilicity.
Collapse
|
10
|
Flat Wall Proximity Effect on Micro-Particle Sedimentation in Non-Newtonian Fluids. Sci Rep 2020; 10:2741. [PMID: 32066769 PMCID: PMC7026440 DOI: 10.1038/s41598-020-59386-5] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Accepted: 01/27/2020] [Indexed: 02/04/2023] Open
Abstract
We investigate the sedimentation of colloidal micro-spheres and red blood cells (RBCs) in non-Newtonian fluid - silicone oil with different viscosities. We use digital holographic microscopy (DHM) to obtain volumetric information of the sedimenting micro-objects. Especially, the numerical refocusing feature of DHM is used to extract the depth information of multiple particles moving inside the fluid. The effects of proximity to a flat wall and the non-Newtonian behavior on the sedimenting micro-spheres and RBCs are studied by trajectory analyzing and velocimetry. We observe that for lower viscosity values the proximity effect is more pronounced. The variation rate of the particle falling velocities versus their distance to the flat wall decreases by increasing the viscosity of the fluid. For RBCs, however, the decreasing of the velocity variations have a smoother trend. The experimental results verify the theoretical prediction that, similar to Newtonian case, a correction factor in Stokes’ law suffices for describing the wall effect.
Collapse
|