New calibration setup for quantitative DCE-US imaging protocol: Toward standardization. Med Phys 2023; 50:5541-5552. [PMID: 36939058 DOI: 10.1002/mp.16362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Revised: 02/27/2023] [Accepted: 02/27/2023] [Indexed: 03/21/2023] Open
Abstract
BACKGROUND The DCE-US (Dynamic Contrast-Enhanced Ultrasonography) imaging protocol predicts the vascular modifications compared with Response Evaluation Criteria in Solid Tumors (RECIST) based mainly on morphological changes. A quantitative biomarker has been validated through the DCE-US multi-centric study for early monitoring of the efficiency of anti-angiogenic cancer treatments. In this context, the question of transposing the use of this biomarker to other types of ultrasound scanners, probes and settings has arisen to maintain the follow-up of patients under anti-angiogenic treatments. As a consequence, radiologists encounter standardization issues between the different generations of ultrasound scanners to perform quantitative imaging protocols. PURPOSE The aim of this study was to develop a new calibration setup to transpose the DCE-US imaging protocol to the new generation of ultrasound scanners using both abdominal and linear probes. METHODS This calibration method has been designed to be easily reproducible and optimized, reducing the time required and cost incurred. It is based on an original set-up that includes using a concentration splitter to measure the variation of the harmonic signal intensity, obtained from the Area Under the time-intensity Curve (AUC) as a function of various contrast-agent concentrations. The splitter provided four different concentrations simultaneously ranging from 12.5% to 100% of the initial concentration of the SonoVue contrast agent (Bracco Imaging S.p.A., Milan, Italy), therefore, measuring four AUCs in a single injection. The plot of the AUC as a function of the four contrast agent concentrations represents the intensity variation of the harmonic signal: the slope being the calibration parameter. The standardization through this method implied that both generations of ultrasound scanners had to have the same slopes to be considered as calibrated. This method was tested on two ultrasound scanners from the same manufacturer (Aplio500, Aplioi900, Canon Medical Systems, Tokyo, Japan). The Aplio500 used the settings defined by the initial multicenter DCE-US study. The Mechanical Index (MI) and the Color Gain (CG) of the Aplioi900 have been adjusted to match those of the Aplio500. The reliability of the new setup was evaluated in terms of measurement repeatability, and reproducibility with the agreement between the measurements obtained once the two ultrasound scanners were calibrated. RESULTS The new setup provided excellent repeatability measurements with a value of 96.8%. Once the two ultrasound scanners have been calibrated for both types of probes, the reproducibility was excellent with the agreement between their respective quantitative measurement was at the lowest 95.4% and at the best 98.8%. The settings of the Aplioi900 (Canon Medical Systems) were adjusted to match those of the Aplio500 (Canon Medical Systems) and these validated settings were for the abdominal probe: MI = 0.13 and CG = 34 dB; and for the linear probe: MI = 0.10 and CG = 38 dB. CONCLUSION This new calibration setup provided reliable measurements and enabled the rapid transfer and the use of the DCE-US imaging protocol on new ultrasound scanners, thus permitting a continuation of the therapeutic evaluation of patients through quantitative imaging.
Collapse
|
2
|
Ambient Pressure Sensitivity of the Subharmonic Response of Coated Microbubbles: Effects of Acoustic Excitation Parameters. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:1550-1560. [PMID: 37100673 DOI: 10.1016/j.ultrasmedbio.2023.02.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/11/2022] [Revised: 01/20/2023] [Accepted: 02/27/2023] [Indexed: 05/17/2023]
Abstract
OBJECTIVE The sensitivity of the acoustic response of microbubbles, specifically a strong correlation between their subharmonic response and the ambient pressure, has motivated development of a non-invasive subharmonic-aided pressure estimation (SHAPE) method. However, this correlation has previously been found to vary depending on the microbubble type, the acoustic excitation and the hydrostatic pressure range. In this study, the ambient pressure sensitivity of microbubble response was investigated. METHODS The fundamental, subharmonic, second harmonic and ultraharmonic responses from an in-house lipid-coated microbubble were measured for excitations with peak negative pressures (PNPs) of 50-700 kPa and frequencies of 2, 3 and 4 MHz in the ambient overpressure range 0-25 kPa (0-187 mmHg) in an in vitro setup. RESULTS The subharmonic response typically has three stages-occurrence, growth and saturation-with increasing excitation PNP. We find distinct decreasing and increasing variations of the subharmonic signal with overpressure that are closely related to the threshold of subharmonic generation in a lipid-shelled microbubble. Above the excitation threshold, that is, in the growth-saturation phase, subharmonic signals decreased linearly with slopes as high as -0.56 dB/kPa with ambient pressure increase; below the threshold excitation (at atmospheric pressure), increasing overpressure triggers subharmonic generation, indicating a lowering of subharmonic threshold, and therefore leads to an increase in subharmonic with overpressure, the maximum enhancement being ∼11 dB for 15 kPa overpressure at 2 MHz and 100 kPa PNP. CONCLUSION This study indicates the possible development of novel and improved SHAPE methodologies.
Collapse
|
3
|
Tissue-Mimicking Materials for Ultrasound-Guided Needle Intervention Phantoms: A Comprehensive Review. ULTRASOUND IN MEDICINE & BIOLOGY 2023; 49:18-30. [PMID: 36210247 DOI: 10.1016/j.ultrasmedbio.2022.07.016] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 07/07/2022] [Accepted: 07/30/2022] [Indexed: 06/16/2023]
Abstract
Ultrasound-guided needle interventions are common procedures in medicine, and tissue-mimicking phantoms are widely used for simulation training to bridge the gap between theory and clinical practice in a controlled environment. This review assesses tissue-mimicking materials from 24 studies as candidates for a high-fidelity ultrasound phantom, including methods for evaluating relevant acoustic and mechanical properties and to what extent the reported materials mimic the superficial layers of biological tissue. Speed of sound, acoustic attenuation, Young's modulus, hardness, needle interaction forces, training efficiency and material limitations were systematically evaluated. Although gelatin and agar have the closest acoustic values to tissue, mechanical properties are limited, and strict storage protocols must be employed to counteract dehydration and microbial growth. Polyvinyl chloride (PVC) has superior mechanical properties and is a suitable alternative if durability is desired and some ultrasound realism to human tissue may be sacrificed. Polyvinyl alcohol (PVA), while also requiring hydration, performs well across all categories. Furthermore, we propose a framework for the evaluation of future ultrasound-guided needle intervention tissue phantoms to increase the fidelity of training programs and thereby improve clinical performance.
Collapse
|
4
|
Phantoms for Quantitative Ultrasound. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2023; 1403:281-301. [PMID: 37495923 DOI: 10.1007/978-3-031-21987-0_13] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/28/2023]
Abstract
Tissue-mimicking materials and phantoms have an important role in quantitative ultrasound. These materials allow for investigation of new techniques with the ability to design materials with properties that are stable over time and available for repeated measurements to refine techniques and analysis algorithms. This chapter presents an overview of the history of phantoms, methods of creation of materials with a variety of acoustic properties, and methods of measurement of those properties. It includes a section addressing the measurement of variance in those techniques using interlaboratory comparisons. There is a wide range of existing tissue-mimicking materials that exhibit properties similar to those of most soft tissues. Ongoing work is part of the expansion of QUS as materials are developed to better mimic specific tissues, geometries, or pathologies.
Collapse
|
5
|
Assessment of the frequency dependence of acoustic properties on material, composition, and scatterer size of the medium. J Med Ultrason (2001) 2022; 49:569-578. [PMID: 36098894 DOI: 10.1007/s10396-022-01235-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Accepted: 05/21/2022] [Indexed: 11/24/2022]
Abstract
PURPOSE The aim of this study was to elucidate the frequency dependence of the speed of sound (SoS) and attenuation coefficients in phantoms with controlled attenuation properties (scatterer density, scatterer size, absorption control material) and rat livers. METHODS The frequency dependence of SoS and attenuation coefficients were evaluated with ultrasound (1-15 MHz) by observing multiple phantoms with different scatterer sizes, densities, and presence or absence of evaporated milk as absorbing media. Normal and fatty model rat livers were examined with the same protocol. RESULTS The phantom results revealed that the scatterer density and SoS of the base media were the dominant factors causing the changes in SoS. Frequency dependence was not observed in SoS. Assessment of the attenuation coefficient showed that the frequency dependence was mainly affected by absorption attenuation when the scatterer was as small as a hepatocyte (i.e. ≤ 10 µm). Scattering attenuation was also observed to affect frequency dependence when the scatterer was as large as lipid droplets (i.e. ≤ 40 µm). CONCLUSION Assuming a consistent size of the main scatterers in the evaluation medium, the frequency dependence of the SoS and attenuation coefficients may provide insight into the scatterer density and the contribution of absorption and scattering attenuation. Further studies in the higher frequency band (up to about 50 MHz) are expected to advance the clinical application of high-frequency ultrasound.
Collapse
|
6
|
Evaluation of ultrasonic scattering in agar-based phantoms using 3D printed scattering molds. J Ultrasound 2022; 25:597-609. [PMID: 34997563 PMCID: PMC9402872 DOI: 10.1007/s40477-021-00630-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2021] [Accepted: 09/30/2021] [Indexed: 10/19/2022] Open
Abstract
PURPOSE Acoustic characterization of tissue mimicking materials in terms of attenuation, absorption, scattering and propagation velocity is essential for their utilisation in experiments, thus sparing the need for living tissues or cadavers. Although there is a vast literature regarding the acoustic characterization of such materials in terms of attenuation or propagation velocity, there is limited data regarding the quantification of the scattering coefficient. Herein stimulated the utilisation of four agar-based phantoms featuring different sizes of scattering agar-structures on one of their surfaces so as to provide experimental evaluation of the magnitude of scattering. METHODS The agar-based phantoms were developed with 6% w/v agar and 4% w/v silica and featured scatterers of sizes of 0-1 mm. The acoustic properties of propagation speed, impedance, insertion loss and attenuation were evaluated utilising the pulse-echo and through-transmission techniques. Scattering was deduced from the data. RESULTS The propagation speed measured at 2.7 MHz was in the range of 1531.23-1542.97 m/s. Respectively the attenuation as measured at 1.1 MHz was in the range of 1.216-1.546 dB/cm increasing with increased scatterer size. Respectively the scattering coefficient was in the range of 0.078-0.324 dB/cm. Moreover, the scattering coefficient was linearly dependent on frequency in the range of 0.8-2.1 MHz indicating a 6-23% effect of the total attenuation. CONCLUSIONS The experimental results demonstrate the utilisation of the procedure for quantification of the scattering coefficient of tissue mimicking materials thus improving the diagnostic and therapeutic uses of ultrasound.
Collapse
|
7
|
A Multilayered, Lesion-Embedded Ultrasound Breast Phantom with Realistic Visual and Haptic Feedback for Needle Biopsy. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1468-1483. [PMID: 35534303 DOI: 10.1016/j.ultrasmedbio.2022.03.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/20/2021] [Revised: 03/08/2022] [Accepted: 03/13/2022] [Indexed: 06/14/2023]
Abstract
Anthropomorphic phantoms have been used to provide residents with training in ultrasound-guided breast biopsy. However, different individuals differ in terms of the acoustic properties and stiffness of their breast tissues. The individual differences should be reflected in the training breast phantoms. This study aimed to develop a breast tissue-mimicking phantom that offers realistic haptic feedback and ultrasound imaging during needle insertion. We investigated the tunability of the mechanical and acoustic properties of breast tissue-mimicking materials (TMMs) to emulate fat, glandular and tumor tissues. The Design of experiments (DOE) methods and physician's feedback were used to reveal the effect of component concentration on Young's modulus and acoustic properties of breast TMMs. Furthermore, the relative backscatter power of the TMM was studied to adjust the contrast between the simulated tumor and background glandular tissue. The results indicated that Young's moduli of TMMs could be altered by adjusting the concentrations of glycerol, agar and olive oil. Changing the concentration of silicon carbide in a TMM could enhance the contrast between the target and the background materials in an ultrasound image. Finally, a series of TMMs were suggested for fat, glandular, benign tumor and malignant tumor tissues. A breast phantom with a tunability appropriately reflecting the individual differences of breast tissues was developed.
Collapse
|
8
|
Contrast-Specific Spherical Lesion Phantoms and Ancillary Analysis Software for the Objective Evaluation of Transrectal Ultrasound System Contrast Detectability. ULTRASOUND IN MEDICINE & BIOLOGY 2022; 48:1615-1627. [PMID: 35659496 DOI: 10.1016/j.ultrasmedbio.2022.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/20/2022] [Revised: 04/11/2022] [Accepted: 04/12/2022] [Indexed: 06/15/2023]
Abstract
Brachytherapy is an efficacious treatment option because of its benefits for patient recovery, dose localization and conformity, but these favorable outcomes can be ensured only if the transrectal ultrasound (TRUS) system is optimized for the specific application of ultrasound-guided prostate brachytherapy. The ability to delineate the prostate from surrounding tissue during TRUS-guided prostate brachytherapy is vital for treatment planning, and consequently, so is the contrast resolution. This study describes the development of task-specific contrast-detail phantoms with clinically relevant contrast and spherical target sizes for contrast-detail performance evaluation of TRUS systems used in the brachytherapy procedure. The procedure for objective assessment of the contrast detectability of the TRUS systems is also described; a program was developed in MATLAB (R2017a, The MathWorks, Natick, MA, USA) to quantitatively analyze image quality in terms of the lesion signal-to-noise ratio (LSNR) and validated with representative control test images. The LSNR of the Hitachi EUB-7500A (2013, Hitachi, Ltd, Tokyo, Japan) TRUS system was measured on sagittal and transverse TRUS images of the contrast-detail phantoms described in this work. Results revealed the efficacy of the device as an image quality evaluation tool and the impact of the size, depth and relative contrast of the targets to the surrounding tissue on the contrast detectability of a TRUS system for both transducer arrays. The MATLAB program objectively measured the contrast detectability of the TRUS system and has the potential to determine optimized imaging parameters that could be designed as part of standardization of the imaging protocol used in TRUS-guided prostate brachytherapy for prostate cancer.
Collapse
|
9
|
Speed of sound in the IEC tissue-mimicking material and its maintenance solution as a function of temperature. ULTRASONICS 2022; 118:106564. [PMID: 34530395 DOI: 10.1016/j.ultras.2021.106564] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 08/18/2021] [Accepted: 08/23/2021] [Indexed: 06/13/2023]
Abstract
Tissue-Mimicking Material (TMM) is defined on IEC International Standards and applied in assessing ultrasonic diagnostic and therapeutic equipment's basic safety and essential performance. One of the TMM that fits IEC standards specification has its recipe described at IEC 60601-2-37, and it is fabricated using glycerol (11.21 %), deionized water (82.95%), benzalkonium chloride (0.47 %), silicon carbide (0.53 %), aluminum oxide 0.3 μm (0.88%), aluminum oxide 3.0 μm (0.94 %), and agar (3.08 %). Glycerol is the component responsible for adjusting the TMM's speed of sound. Moreover, it is recommended to store TMM in a closed container immersed in a mixture of water (88.1 %)/glycerol (11.9 %) to prevent it from drying out and avoiding air contact. The literature points out TMM measurements underwater can alter the speed of sound property as TMM tends to lose glycerol. Herein, the authors proposed to assess the viability of measuring the TMM speed of sound in the water/glycerol maintenance solution. First, the authors characterized the maintenance solution's speed of sound for a temperature range of 20 °C to 45 °C. Then, the group velocity of a set of TMM was measured underwater and in the maintenance solution for the same temperature range. The respective group velocity expanded uncertainty was calculated. The results indicate it is feasible to measure TMM in the maintenance solution, achieving group velocity values with no statistical difference from the ones measured underwater in the temperature range of 20 °C to 40 °C.
Collapse
|
10
|
Low-Cost and Easily Fabricated Ultrasound-Guided Breast Phantom for Breast Biopsy Training. APPLIED SCIENCES-BASEL 2021. [DOI: 10.3390/app11167728] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
We aimed to develop an inexpensive and easy-to-fabricate gelatin-based training phantom for improving the breast biopsy skill and confidence level of residents. Young’s modulus and acoustic properties of the gelatin tissue phantom and simulated tumors were investigated. Six residents were requested to evaluate the effectiveness of the breast phantom. The results showed that 83% (n = 5) of the participants agreed that the ultrasound image quality produced by the breast phantom was excellent or good. Only 17% (n = 1) of the participants claimed that there was room for improvement for the haptic feedback they received during the placement of the core needle into the breast phantom. The mean pre-instructional score was 17% (SD 17%) for all participants. The mean post-instructional score was 83% (SD 17%), giving an overall improvement of 67%. In conclusion, the mean needle biopsy skill and confidence levels of the participants substantially increased through simulation training on our breast phantom. The participants’ feedback showed the phantom is sufficiently realistic in terms of ultrasound imaging and haptic feedback during needle insertion; thus, the training outcome can be linked to the performance of residents when they perform a live biopsy.
Collapse
|
11
|
Feasibility of Reference Material Certification for Speed of Sound and Attenuation Coefficient Based on Standard Tissue-Mimicking Material. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:1904-1919. [PMID: 33896678 DOI: 10.1016/j.ultrasmedbio.2021.03.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2020] [Revised: 03/16/2021] [Accepted: 03/17/2021] [Indexed: 06/12/2023]
Abstract
Speed of sound and attenuation are essential for characterizing reference materials such as biological tissue-mimicking materials (TMMs) used in ultrasonic applications. There are many publications on the manufacture of TMMs and the measurement of their properties. However, no studies in the literature have applied the metrological approach of International Organization for Standardization (ISO) Guide 35 to certify biological ultrasound TMMs as candidates for reference materials (RMs). The work described here was aimed at studying the process for manufacturing fat, muscle and aorta artery TMMs, including the study of the homogeneity, stability, trend and characterization of TMMs. The properties of interest were the speed of sound (SoS) and attenuation coefficient (AttC) at 7.5 MHz, with target expanded uncertainty of 40 m/s and 0.3 dB/cm, respectively. The short-term stability study was 2 mo at 4°C and 40°C (simulating possible transportation conditions). The long-term stability study lasted an additional 4 mo with the TMM at 22°C (simulating possible storage conditions). Homogeneity was evaluated before the stability study. Uncertainties associated with homogeneity, stability, characterization and trend were duly calculated. No trend was observed in this study, but the AttC spread widely during the stability test, substantially enlarging the final uncertainty. Therefore, this property could not be used to certify TMM candidates as RMs. However, the SoSs for most TMMs lay within the target uncertainty, disclosing viability to certify TMMs as RMs for this property. Assigned values for SoS were 1560 m/s for aorta TMM with an average expanded uncertainty for certificate validity of 12 mo (Ue;12=20 m/s), 1552 m/s for muscle TMM (Ue;12=20 m/s) and 1494 m/s for fat TMM (Ue;12=11 m/s). Thus, TMMs were proved suitable to be certified as RMs for SoS.
Collapse
|
12
|
In vitro characterisation of ultrasound-induced heating effects in the mother and fetus: A clinical perspective. ULTRASOUND (LEEDS, ENGLAND) 2021; 29:73-82. [PMID: 33995553 PMCID: PMC8083135 DOI: 10.1177/1742271x20953197] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/26/2020] [Accepted: 08/04/2020] [Indexed: 12/11/2022]
Abstract
INTRODUCTION The quantification of heating effects during exposure to ultrasound is usually based on laboratory experiments in water and is assessed using extrapolated parameters such as the thermal index. In our study, we have measured the temperature increase directly in a simulator of the maternal-fetal environment, the 'ISUOG Phantom', using clinically relevant ultrasound scanners, transducers and exposure conditions. METHODS The study was carried out using an instrumented phantom designed to represent the pregnant maternal abdomen and which enabled temperature recordings at positions in tissue mimics which represented the skin surface, sub-surface, amniotic fluid and fetal bone interface. We tested four different transducers on a commercial diagnostic scanner. The effects of scan duration, presence of a circulating fluid, pre-set and power were recorded. RESULTS The highest temperature increase was always at the transducer-skin interface, where temperature increases between 1.4°C and 9.5°C were observed; lower temperature rises, between 0.1°C and 1.0°C, were observed deeper in tissue and at the bone interface. Doppler modes generated the highest temperature increases. Most of the heating occurred in the first 3 minutes of exposure, with the presence of a circulating fluid having a limited effect. The power setting affected the maximum temperature increase proportionally, with peak temperature increasing from 4.3°C to 6.7°C when power was increased from 63% to 100%. CONCLUSIONS Although this phantom provides a crude mimic of the in vivo conditions, the overall results showed good repeatability and agreement with previously published experiments. All studies showed that the temperature rises observed fell within the recommendations of international regulatory bodies. However, it is important that the operator should be aware of factors affecting the temperature increase.
Collapse
|
13
|
Development and Preliminary Evaluation of an Anthropomorphic Trans-rectal Ultrasound Prostate Brachytherapy Training Phantom. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:833-846. [PMID: 33358053 DOI: 10.1016/j.ultrasmedbio.2020.11.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2020] [Revised: 11/18/2020] [Accepted: 11/19/2020] [Indexed: 06/12/2023]
Abstract
The quality of the trans-rectal ultrasound (TRUS) image, and thus seed placement during the prostate brachytherapy (PBT) procedure, relies on the user's technical and clinical competency. Simulation-based medical education can provide a structured approach for the acquisition of clinical competencies, but the efficacy of the training relies on the fidelity of the training simulators. In this work, the design, development and preliminary evaluation of an anthropomorphic training phantom for TRUS PBT is described. TRUS clinical patient data informed the design of 3-D printed moulds to fabricate prostate targets. Tissue-mimicking materials were included that had the sonographic characteristics of the prostate and overlying tissues, as well as the clinically relevant physical response, to provide haptic feedback to the user. Through an iterative design process, prototypes were constructed. These prototypes were quantitatively evaluated using a specification list and evaluated by an experienced clinical brachytherapy oncologist; their feedback was implemented, and the results of this evaluation are presented.
Collapse
|
14
|
Acoustic impedance measurement of tissue mimicking materials by using scanning acoustic microscopy. ULTRASONICS 2021; 110:106274. [PMID: 33130362 DOI: 10.1016/j.ultras.2020.106274] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Revised: 10/02/2020] [Accepted: 10/06/2020] [Indexed: 06/11/2023]
Abstract
Tissue-mimicking materials (TMMs) play a key role in the quality assurance of ultrasound diagnostic equipment and should have acoustic properties similar to human tissues. We propose a method to quantify the acoustic properties of TMM samples through the use of an 80 MHz Scanning Acoustic Microscopy (SAM), which provides micrometer resolution and fast data recording. We produced breast TMM samples in varying compositions that resulted in acoustic impedance values in the range of 1.373 ± 0.031 and 1.707 ± 0.036 MRayl. Additionally, liver TMM and blood mimicking fluid (BMF) samples were prepared that had acoustic impedance values of 1.693 ± 0.085 MRayl and 1.624 ± 0.006 MRayl, respectively. The characterization of the TMMs by SAM may provide reproducible and uniform acoustic reference data for tissue substitutes in a single-run microscopy experiment.
Collapse
|
15
|
Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging. SENSORS 2020; 20:s20082400. [PMID: 32340281 PMCID: PMC7219586 DOI: 10.3390/s20082400] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 04/20/2020] [Accepted: 04/21/2020] [Indexed: 11/16/2022]
Abstract
The aim of this work was to develop multimodal anthropomorphic breast phantoms suitable for evaluating the imaging performance of a recently-introduced Microwave Imaging (MWI) technique in comparison to the established diagnostic imaging modalities of Magnetic Resonance Imaging (MRI), Ultrasound (US), mammography and Computed Tomography (CT). MWI is an emerging technique with significant potential to supplement established imaging techniques to improve diagnostic confidence for breast cancer detection. To date, numerical simulations have been used to assess the different MWI scanning and image reconstruction algorithms in current use, while only a few clinical trials have been conducted. To bridge the gap between the numerical simulation environment and a more realistic diagnostic scenario, anthropomorphic phantoms which mimic breast tissues in terms of their heterogeneity, anatomy, morphology, and mechanical and dielectric characteristics, may be used. Key in this regard is achieving realism in the imaging appearance of the different healthy and pathologic tissue types for each of the modalities, taking into consideration the differing imaging and contrast mechanisms for each modality. Suitable phantoms can thus be used by radiologists to correlate image findings between the emerging MWI technique and the more familiar images generated by the conventional modalities. Two phantoms were developed in this study, representing difficult-to-image and easy-to-image patients: the former contained a complex boundary between the mammary fat and fibroglandular tissues, extracted from real patient MRI datasets, while the latter contained a simpler and less morphologically accurate interface. Both phantoms were otherwise identical, with tissue-mimicking materials (TMMs) developed to mimic skin, subcutaneous fat, fibroglandular tissue, tumor and pectoral muscle. The phantoms’ construction used non-toxic materials, and they were inexpensive and relatively easy to manufacture. Both phantoms were scanned using conventional modalities (MRI, US, mammography and CT) and a recently introduced MWI radar detection procedure called in-coherent Multiple Signal Classification (I-MUSIC). Clinically realistic artifact-free images of the anthropomorphic breast phantoms were obtained using the conventional imaging techniques as well as the emerging technique of MWI.
Collapse
|
16
|
Production and clinical evaluation of breast lesion skin markers for automated three-dimensional ultrasonography of the breast: a pilot study. Eur Radiol 2020; 30:3356-3362. [PMID: 32060713 PMCID: PMC7248012 DOI: 10.1007/s00330-020-06695-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2019] [Revised: 01/09/2020] [Accepted: 01/30/2020] [Indexed: 11/24/2022]
Abstract
Objectives Automated ultrasound of the breast has the advantage to have the whole breast scanned by technicians. Consequently, feedback to the radiologist about concurrent focal abnormalities (e.g., palpable lesions) is lost. To enable marking of patient- or physician-reported focal abnormalities, we aimed to develop skin markers that can be used without disturbing the interpretability of the image. Methods Disk-shaped markers were casted out of silicone. In this IRB-approved prospective study, 16 patients were included with a mean age of 57 (39–85). In all patients, the same volume was imaged twice using an automated breast ultrasound system, once with and once without a marker in place. Nine radiologists from two medical centers filled scoring forms regarding image quality, image interpretation, and confidence in providing a diagnosis based on the images. Results Marker adhesion was sufficient for automated scanning. Observer scores showed a significant shift in scores from excellent to good regarding diagnostic yield/image quality (χ2, 15.99, p < 0.01), and image noise (χ2, 21.20, p < 0.01) due to marker presence. In 93% of cases, the median score of observers “agree” with the statement that marker-induced noise did not influence image interpretability. Marker presence did not interfere with confidence in diagnosis (χ2, 6.00, p = 0.20). Conclusion Inexpensive, easy producible skin markers can be used for accurate lesion marking in automated ultrasound examinations of the breast while image interpretability is preserved. Any marker-induced noise and decreased image quality did not affect confidence in providing a diagnosis. Key Points • The use of a skin marker enables the reporting radiologist to identify a location which a patient is concerned about. • The developed skin marker can be used for accurate breast lesion marking in ultrasound examinations.
Collapse
|
17
|
Tunability of Acoustic and Mechanical Behaviors in Breast Tissue Mimicking Materials. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:1998-2002. [PMID: 31946292 DOI: 10.1109/embc.2019.8857843] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In radiology practices, the ultrasound-guided breast biopsy is among the most commonly performed minimally invasive procedures. However, many radiology residents in their graduate residencies are found with little or no hands-on experience with ultrasound-guided breast procedures. To enhance safety, the problem can be solved by the use of anthropomorphic training phantoms which can provide the resident with realistic ultrasound imaging and needle insertion haptic feedback. Stiffness and acoustic properties of breast tissues vary between different people. The training breast phantom should be able to possess different acoustic and mechanical properties which conform the inconsistencies found in real tissues among people. Therefore, this paper investigates the tunability of acoustic and mechanical behaviors in breast tissue mimicking materials (TMMs). Experiments of central composite design (CCD) with a center point, four corner points, and an additional four axis points were used to fit the non-linear regression model of the speed of sound. The same design of experiment approach was then used to fit the second-order response surface of the attenuation coefficient. Suitable series of tissue mimicking materials for the glandular tissue and malignant lesion were suggested. Latin hypercube design method was conducted to evaluate the main factors that affected the mechanical property (Young's modulus) of tissue mimicking materials. The results showed that the recipe of tissue mimicking materials could be customized to possess different acoustic and mechanical properties which conform the inconsistencies found in real breast tissues.
Collapse
|
18
|
Investigation of the assessment of low degree (<50%) renal artery stenosis based on velocity flow profile analysis using Doppler ultrasound: An in-vitro study. Phys Med 2019; 65:209-218. [PMID: 31518907 DOI: 10.1016/j.ejmp.2019.08.016] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 08/21/2019] [Accepted: 08/23/2019] [Indexed: 11/24/2022] Open
Abstract
PURPOSE Renal arterial stenosis can lead to disrupted renal function due to reduced blood flow to the kidneys and is largely thought to be caused by atherosclerosis. Current diagnostic strategies for renal arterial stenosis rely on detecting large degree stenoses (>50%). This study aimed to test the viability of using Doppler ultrasound to assess velocity profiles to detect the presence of low degree (<50%) stenoses. METHODS A series of anatomically realistic renal artery flow phantoms were constructed exhibiting a range of low degree stenoses (symmetric and asymmetric). The behaviour of fluid flow in the phantoms was examined using Doppler ultrasound and analysed to calculate the clinical biomarker, wall shear stress. RESULTS A number of fluid behaviours were observed in relation to stenosis degree: asymmetric stenoses tended to result in a skewing of peak velocities away from the centre of the vessel towards the outer wall, the magnitude of increase in velocity was observed to correlate with stenosis degree, and the wall shear stress curves observed large peaks in the presence of even the lowest degree stenosis (20%). CONCLUSIONS Doppler ultrasound could potentially be utilised to diagnose low degree stenoses in a clinical setting. Doppler ultrasound in conjunction with wall shear stress analysis in particular has significant potential in the diagnosis of renal artery stenosis.
Collapse
|
19
|
Development and Characterization of Medical Phantoms for Ultrasound Imaging Based on Customizable and Mouldable Polyvinyl Alcohol Cryogel-Based Materials and 3-D Printing: Application to High-Frequency Cranial Ultrasonography in Infants. ULTRASOUND IN MEDICINE & BIOLOGY 2019; 45:2226-2241. [PMID: 31128769 DOI: 10.1016/j.ultrasmedbio.2019.04.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 04/29/2019] [Accepted: 04/29/2019] [Indexed: 06/09/2023]
Abstract
This work presents an affordable and easily customizable methodology for phantom manufacturing, which can be used to mimic different anatomic organs and structures. This methodology is based on the use of polyvinyl alcohol-based cryogels as a physical substitute for biologic soft tissues and of 3-D printed polymers for hard tissues, moulding and supporting elements. Thin and durable soft-tissue mimicking layers and multilayer arrangements can be obtained using these materials. Special attention was paid to the acoustic properties (sound speed, attenuation coefficient and mechanical impedance) of the materials developed to simulate soft tissues. These properties were characterized as a function of the additives concentration (propylene-glycol and alumina particles). The polyvinyl alcohol formulation proposed in this work is stable over several freeze-thaw cycles, allowing the manufacturing of multilayer materials with controlled properties. The manufacturing methodology presented was applied to the development of a phantom for high-frequency cranial ultrasonography in infants. This phantom was able to reproduce the main characteristics of the ultrasound images obtained in neonates through the anterior fontanel, down to 8-mm depth.
Collapse
|
20
|
An investigation of the detection capability of pulsed wave duplex Doppler of low grade stenosis using ultrasound contrast agent microbubbles - An in-vitro study. ULTRASONICS 2019; 96:48-54. [PMID: 31004864 DOI: 10.1016/j.ultras.2019.04.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/26/2018] [Revised: 03/11/2019] [Accepted: 04/02/2019] [Indexed: 06/09/2023]
Abstract
OBJECTIVE The objective of the study was to investigate whether clinically used ultrasonic contrast agents improved the accuracy of spectral Doppler ultrasound in the detection of low grade (<50%) renal artery stenosis. Low grade stenoses in the renal artery are notoriously difficult to reliably detect using Doppler ultrasound due to difficulties such as overlying fat and bowel gas. METHODS A range of anatomically-realistic renal artery phantoms with varying low degrees of stenosis (0, 30 and 50%) were constructed and peak velocity data was measured from within the pre-stenotic and mid-stenotic regions in each phantom, for both unenhanced and contrast-enhanced spectral Doppler data acquisitions. The effect of a 20 mm overlying fat layer on the ultrasound beam distortion and phase aberration, and hence on the measured peak velocity data, was also investigated. RESULTS The overlying fat layer produced a statistically significant underestimation (p < 0.01) in both the peak velocity and peak velocity ratio [Stenotic Region(Vmax)/Pre-stenotic Region(Vmax)] for the 0% and 30% stenosis models, but not the 50% model. A statistically significant increase (p < 0.01) in the peak velocity was found in the contrast-enhanced Doppler spectra; however, no significant difference was found between the unenhanced and contrast enhanced peak velocity ratio data, which suggests that the ratio metric has better diagnostic accuracy. The peak velocity ratios determined for each of the contrast-enhanced phantoms correctly predicted if the phantom had a stenosis and furthermore correctly classified the degree of stenosis. CONCLUSION Contrast-enhanced Doppler ultrasound could significantly assist in the early detection of renal artery disease.
Collapse
|
21
|
Abstract
Diagnostic endoscopy in the gastrointestinal tract has remained largely unchanged for decades and is limited to the visualization of the tissue surface, the collection of biopsy samples for diagnoses, and minor interventions such as clipping or tissue removal. In this work, we present the autonomous servoing of a magnetic capsule robot for in-situ, subsurface diagnostics of microanatomy. We investigated and showed the feasibility of closed-loop magnetic control using digitized microultrasound (μUS) feedback; this is crucial for obtaining robust imaging in an unknown and unconstrained environment. We demonstrated the functionality of an autonomous servoing algorithm that uses μUS feedback, both on benchtop trials as well as in-vivo in a porcine model. We have validated this magnetic-μUS servoing in instances of autonomous linear probe motion and were able to locate markers in an agar phantom with 1.0 ± 0.9 mm position accuracy using a fusion of robot localization and μUS image information. This work demonstrates the feasibility of closed-loop robotic μUS imaging in the bowel without the need for either a rigid physical link between the transducer and extracorporeal tools or complex manual manipulation.
Collapse
|
22
|
Attenuation Coefficients of the Individual Components of the International Electrotechnical Commission Agar Tissue-Mimicking Material. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:2371-2378. [PMID: 30076033 DOI: 10.1016/j.ultrasmedbio.2018.06.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2017] [Revised: 05/18/2018] [Accepted: 06/06/2018] [Indexed: 06/08/2023]
Abstract
Tissue-mimicking materials (TMMs) are widely used in quality assurance (QA) phantoms to assess the performance of ultrasound scanners. The International Electrotechnical Commission (IEC) defines the acoustic parameters of up to 10MHz. To manufacture a TMM that closely mimics the acoustical properties of small animal soft tissue at high frequencies, the acoustic properties of each of the individual component ingredients used in the IEC agar-TMM recipe need to be quantified. This study was aimed at evaluating whether the overall attenuation coefficient of the IEC agar-TMM is the linear sum of the attenuation coefficients of each of its ingredients. Eight batches of agar-based materials were manufactured with different combinations of ingredients from the IEC agar-TMM recipe. The percentage concentration of each ingredient used in the individual mixes was identical to that specified in the IEC recipe. The attenuation of each of these batches was measured over the ultrasound frequency range 12-50MHz, and the attenuation value of the agar component was subtracted from the attenuation values of the other batches. Batch attenuation values, representing the attenuation of individual components within the IEC agar-TMM, were then summated and yielded attenuation values that accurately reproduced the attenuation of the IEC agar-TMM. This information forms a valuable resource for the future development of TMMs with acoustic properties similar to those of soft tissue at high frequencies.
Collapse
|
23
|
Determination of Acoustic Cavitation Probabilities and Thresholds Using a Single Focusing Transducer to Induce and Detect Acoustic Cavitation Events: I. Method and Terminology. ULTRASOUND IN MEDICINE & BIOLOGY 2018; 44:377-396. [PMID: 29195754 DOI: 10.1016/j.ultrasmedbio.2017.08.1946] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/05/2016] [Revised: 07/30/2017] [Accepted: 08/09/2017] [Indexed: 06/07/2023]
Abstract
A method to determine acoustic cavitation probabilities in tissue-mimicking materials (TMMs) is described that uses a high-intensity focused ultrasound (HIFU) transducer for both inducing and detecting the acoustic cavitation events. The method was evaluated by studying acoustic cavitation probabilities in agar-based TMMs with and without scatterers and for different sonication modes like continuous wave, single pulses (microseconds to milliseconds) and repeated burst signals. Acoustic cavitation thresholds (defined here as the peak rarefactional in situ pressure at which the acoustic cavitation probability reaches 50%) at a frequency of 1.06 MHz were observed between 1.1 MPa (for 1 s of continuous wave sonication) and 4.6 MPa (for 1 s of a repeated burst signal with 25-cycle burst length and 10-ms burst period) in a 3% (by weight) agar phantom without scatterers. The method and its evaluation are described, and general terminology useful for standardizing the description of insonation conditions and comparing results is provided. In the accompanying second part, the presented method is used to systematically study the acoustic cavitation thresholds in the same material for a range of sonication modes.
Collapse
|
24
|
Non-invasive Estimation of Temperature during Physiotherapeutic Ultrasound Application Using the Average Gray-Level Content of B-Mode Images: A Metrological Approach. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1938-1952. [PMID: 28619277 DOI: 10.1016/j.ultrasmedbio.2017.04.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/10/2016] [Revised: 03/03/2017] [Accepted: 04/09/2017] [Indexed: 06/07/2023]
Abstract
Healing therapies that make use of ultrasound are based on raising the temperature in biological tissue. However, it is not possible to heal impaired tissue by applying a high dose of ultrasound. The temperature of the tissue is ultimately the physical quantity that has to be assessed to minimize the risk of undesired injury. Invasive temperature measurement techniques are easy to use, despite the fact that they are detrimental to human well being. Another approach to assessing a rise in tissue temperature is to derive the material's general response to temperature variations from ultrasonic parameters. In this article, a method for evaluating temperature variations is described. The method is based on the analytical study of an ultrasonic image, in which gray-level variations are correlated to the temperature variations in a tissue-mimicking material. The physical assumption is that temperature variations induce wave propagation changes modifying the backscattered ultrasound signal, which are expressed in the ultrasonographic images. For a temperature variation of about 15°C, the expanded uncertainty for a coverage probability of 0.95 was found to be 2.5°C in the heating regime and 1.9°C in the cooling regime. It is possible to use the model proposed in this article in a straightforward manner to monitor temperature variation during a physiotherapeutic ultrasound application, provided the tissue-mimicking material approach is transferred to actual biological tissue. The novelty of such approach resides in the metrology-based investigation outlined here, as well as in its ease of reproducibility.
Collapse
|
25
|
|
26
|
Broadband Acoustic Measurement of an Agar-Based Tissue-Mimicking-Material: A Longitudinal Study. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:1494-1505. [PMID: 28450032 DOI: 10.1016/j.ultrasmedbio.2017.02.019] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2016] [Revised: 02/27/2017] [Accepted: 02/27/2017] [Indexed: 06/07/2023]
Abstract
Commercially available ultrasound quality assurance test phantoms rely on the long-term acoustic stability of the tissue-mimicking-material (TMM). Measurement of the acoustic properties of the TMM can be technically challenging, and it is important to ensure its stability. The standard technique is to film-wrap samples of TMM and to measure the acoustic properties in a water bath. In this study, a modified technique was proposed whereby the samples of TMM are measured in a preserving fluid that is intended to maintain their characteristics. The acoustic properties were evaluated using a broadband pulse-echo substitution technique over the frequency range 4.5-50 MHz at 0, 6 and 12 months using both techniques. For both techniques, the measured mean values for the speed of sound and attenuation were very similar and within the International Electrotechnical Commission-recommended value. However, the results obtained using the proposed modified technique exhibited greater stability over the 1-y period compared with the results acquired using the standard technique.
Collapse
|
27
|
Metrological Validation of a Measurement Procedure for the Characterization of a Biological Ultrasound Tissue-Mimicking Material. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:323-331. [PMID: 27756496 DOI: 10.1016/j.ultrasmedbio.2016.09.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/06/2016] [Revised: 09/06/2016] [Accepted: 09/06/2016] [Indexed: 06/06/2023]
Abstract
The speed of sound and attenuation are important properties for characterizing reference materials such as biological phantoms used in ultrasound applications. There are many publications on the manufacture of ultrasonic phantoms and the characterization of their properties. However, few studies have applied the principles of metrology, such as the expression of the uncertainty of measurement. The objective of this study is to validate a method for characterizing the speed of sound and the attenuation coefficient of tissue-mimicking material (TMM) based on the expression of the measurement of uncertainty. Six 60-mm-diameter TMMs were fabricated, three 10 mm thick and three 20 mm thick. The experimental setup comprised two ultrasonic transducers, acting as transmitter or receiver depending on the stage of the measurement protocol, both with a nominal center frequency of 5 MHz and an element diameter of 12.7 mm. A sine burst of 20 cycles and 20-V peak-to-peak amplitude at 5 MHz excited the transmitter transducer, producing a maximum pressure of 0.06 MPa. The measurement method was based on the through-transmission substitution immersion technique. The speed of sound measurement system was validated using a calibrated stainless-steel cylinder as reference material, and normalized errors were <0.8. The attenuation coefficient measurement method was validated using replicated measurements under repeatability conditions. The normalized error between the two measurement sets was <1. The proposed uncertainty models for the measurements of the speed of sound and the attenuation coefficient can help other laboratories develop their own uncertainty models. These validated measurement methods can be used to certify a TMM as a reference material for biotechnological applications.
Collapse
|
28
|
Temperature elevation measured in a tissue-mimicking phantom for transvaginal ultrasound at clinical settings. ULTRASOUND : JOURNAL OF THE BRITISH MEDICAL ULTRASOUND SOCIETY 2016; 25:6-15. [PMID: 28228820 DOI: 10.1177/1742271x16684529] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/31/2016] [Accepted: 10/18/2016] [Indexed: 11/16/2022]
Abstract
INTRODUCTION This paper reports the results of an audit to assess the possible thermal hazard associated with the clinical use of ultrasound scanners in UK Hospitals for transvaginal ultrasound imaging. METHODS An anatomically relevant phantom composed of a block of agar-based tissue mimicking material with embedded thermal sensors was developed. Seventeen hospitals around the UK were visited and a total of 64 configurations were tested. A representative typical scanning protocol was adopted, which primarily used B-mode with 30 s periods of colour-flow and pulsed Doppler modes for both gynaecology and obstetrics pre-sets. RESULTS The results confirmed that the highest temperature increase is always at the surface. The greatest temperature rise measured across all the systems was 3.6℃, with an average of 2.0℃ and 2.16℃ for gynaecology and obstetrics pre-sets, respectively. For some systems, the temperature increased rapidly when selecting one of the Doppler modes, so using them for longer than 30 s will in many cases lead to greater heating. It is also shown that, in agreement with previous studies, the displayed thermal index greatly underestimates the temperature rise, particularly close to the transducer face but even to distances approaching 2 cm. CONCLUSIONS Overall, the results of the audit for the temperature rise during transvaginal ultrasound at clinical settings fell within the limits indicated by the national and international standards, for the pre-sets tested and following a representative typical scanning protocol. Only selected pre-sets were tested and the scanner outputs were not maximised (for example by using zoom, greater depth or narrow sector angles). Consequently, higher temperatures than those measured can certainly be achieved.
Collapse
|
29
|
The Feasibility of Thermal Imaging as a Future Portal Imaging Device for Therapeutic Ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2016; 42:2033-2038. [PMID: 27174419 DOI: 10.1016/j.ultrasmedbio.2016.03.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/17/2015] [Revised: 03/17/2016] [Accepted: 03/23/2016] [Indexed: 06/05/2023]
Abstract
This technical note describes a prototype thermally based portal imaging device that allows mapping of energy deposition on the surface of a tissue mimicking material in a focused ultrasound surgery (FUS) beam by using an infrared camera to measure the temperature change on that surface. The aim of the work is to explore the feasibility of designing and building a system suitable for rapid quality assurance (QA) for use with both ultrasound- and magnetic resonance (MR) imaging-guided clinical therapy ultrasound systems. The prototype was tested using an MR-guided Sonalleve FUS system (with the treatment couch outside the magnet bore). The system's effective thermal noise was 0.02°C, and temperature changes as low as 0.1°C were easily quantifiable. The advantages and drawbacks of thermal imaging for QA are presented through analysis of the results of an experimental session.
Collapse
|
30
|
Characterisation of Elastic and Acoustic Properties of an Agar-Based Tissue Mimicking Material. Ann Biomed Eng 2015; 43:2587-96. [DOI: 10.1007/s10439-015-1294-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Accepted: 02/28/2015] [Indexed: 11/28/2022]
|
31
|
Reference characterisation of sound speed and attenuation of the IEC agar-based tissue-mimicking material up to a frequency of 60 MHz. ULTRASOUND IN MEDICINE & BIOLOGY 2015; 41:317-33. [PMID: 25220268 DOI: 10.1016/j.ultrasmedbio.2014.04.018] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/12/2014] [Revised: 04/25/2014] [Accepted: 04/26/2014] [Indexed: 05/25/2023]
Abstract
To support the development of clinical applications of high-frequency ultrasound, appropriate tissue-mimicking materials (TMMs) are required whose acoustic properties have been measured using validated techniques. This paper describes the characterisation of the sound speed (phase velocity) and attenuation coefficient of the International Electrotechnical Commission (IEC) agar-based TMM over the frequency range 1 to 60 MHz. Measurements implemented a broadband through-transmission substitution immersion technique over two overlapping frequency ranges, with co-axially aligned 50 MHz centre-frequency transducers employed for characterisation above 15 MHz. In keeping with usual practice employed within the technical literature, thin acoustic windows (membranes) made of 12-μm-thick Mylar protected the TMM from water damage. Various important sources of uncertainty that could compromise measurement accuracy have been identified and evaluated through a combination of experimental studies and modelling. These include TMM sample thickness, measured both manually and acoustically, and the influence of interfacial losses that, even for thin protective membranes, are significant at the frequencies of interest. In agreement with previous reports, the attenuation coefficient of the IEC TMM exhibited non-linear frequency dependence, particularly above 20 MHz, yielding a value of 0.93 ± 0.04 dB cm(-1) MHz(-1) at 60 MHz, derived at 21 ± 0.5°C. For the first time, phase velocity, measured with an estimated uncertainty of ±3.1 m s(-1), has been found to be dispersive over this extended frequency range, increasing from 1541 m s(-1) at 1 MHz to 1547 m s(-1) at 60 MHz. This work will help standardise acoustic property measurements, and establishes a reference measurement capability for TMMs underpinning clinical applications at elevated frequencies.
Collapse
|
32
|
acoustic assessment of a konjac–carrageenan tissue-mimicking material aT 5–60 MHZ. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:2895-902. [PMID: 25438864 PMCID: PMC4259902 DOI: 10.1016/j.ultrasmedbio.2014.07.006] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/31/2014] [Revised: 07/03/2014] [Accepted: 07/11/2014] [Indexed: 05/10/2023]
Abstract
The acoustic properties of a robust tissue-mimicking material based on konjac–carrageenan at ultrasound frequencies in the range 5–60 MHz are described. Acoustic properties were characterized using two methods: a broadband reflection substitution technique using a commercially available preclinical ultrasound scanner (Vevo 770, FUJIFILM VisualSonics, Toronto, ON, Canada), and a dedicated high-frequency ultrasound facility developed at the National Physical Laboratory (NPL, Teddington, UK), which employed a broadband through-transmission substitution technique. The mean speed of sound across the measured frequencies was found to be 1551.7 ± 12.7 and 1547.7 ± 3.3 m s21, respectively. The attenuation exhibited a non-linear dependence on frequency, f (MHz), in the form of a polynomial function: 0.009787f2 1 0.2671f and 0.01024f2 1 0.3639f, respectively. The characterization of this tissue-mimicking material will provide reference data for designing phantoms for preclinical systems, which may, in certain applications such as flow phantoms, require a physically more robust tissuemimicking material than is currently available.
Collapse
|
33
|
Assessing the imaging capabilities of radial mechanical and electronic echo-endoscopes using the resolution integral. ULTRASOUND IN MEDICINE & BIOLOGY 2014; 40:1896-1907. [PMID: 24798390 DOI: 10.1016/j.ultrasmedbio.2014.02.009] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/31/2013] [Revised: 12/16/2013] [Accepted: 02/08/2014] [Indexed: 06/03/2023]
Abstract
Over the past decade there have been significant advances in endoscopic ultrasound (EUS) technology. Although there is an expectation that new technology will deliver improved image quality, there are few methods or phantoms available for assessing the capabilities of mechanical and electronic EUS systems. The aim of this study was to investigate the possibility of assessing the imaging capability of available EUS technologies using measurements of the resolution integral made with an Edinburgh Pipe Phantom. Various radial EUS echo-endoscopes and probes were assessed using an Edinburgh Pipe Phantom. Measurements of the resolution integral (R), depth of field (LR) and characteristic resolution (DR) were made at all operating frequencies. The mean R value for Fuji miniprobes was 16.0. The GF-UM20 and GF-UM2000 mechanical radial scopes had mean R values of 24.0 and 28.5, respectively. The two electronic radial echo-endoscopes had similar mean R values of 34.3 and 34.6 for the Olympus GF-UE260 and Fujinon EG-530 UR scopes, respectively. Despite being older technology, the mechanical GF-UM2000 scope had superior characteristic resolution (DR), but could not compare with the depths of field (LR) delivered by the current generation of electronic radial scopes, especially at the standard operating frequencies of 7.5 and 12 MHz.
Collapse
|
34
|
Tumor Localization Using Magnetic Nanoparticle-Induced Acoustic Signals. IEEE Trans Biomed Eng 2014; 61:2313-23. [DOI: 10.1109/tbme.2013.2286638] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
35
|
Carotid atherosclerotic plaque characterisation by measurement of ultrasound sound speed in vitro at high frequency, 20 MHz. ULTRASONICS 2014; 54:428-441. [PMID: 23683797 DOI: 10.1016/j.ultras.2013.04.015] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2013] [Revised: 04/17/2013] [Accepted: 04/19/2013] [Indexed: 06/02/2023]
Abstract
This study aimed to utilise a tissue mimicking material (TMM) in order to embed in vitro carotid plaque tissue so that its acoustic properties could be assessed. Here, an International Electrotechnical Commission (IEC) agar-based TMM was adapted to a clear gel by removal of the particulates. This clear TMM was measured with sound speed at 1540 ms(-1) and an attenuation coefficient of 0.15 dB cm(-1)MHz(-1). Composite sound speed was then measured through the embedded material using a scanning acoustic microscope (SAM). Both broadband reflection and transmission techniques were performed on each plaque specimen in order to ensure the consistency of the measurement of sound speed, both at 21 °C and 37 °C. The plaque was measured at two temperatures to investigate any effect on the lipid content of the plaque. The contour maps from its associated attenuation plots were used to match the speed data to the photographic mask of the plaque outline. This physical matching was then used to derive the sound speed from the percentage composition seen in the histological data by solution of simultaneous equations. Individual speed values for five plaque components were derived; TMM, elastin, fibrous/collagen, calcification and lipid. The results for derived sound speed in the TMM were consistently close to the expected value of soft tissue, 1540 ms(-1). The fibrous tissue showed a mean value of 1584 ms(-1) at 37 °C. The derived sound speeds for elastic and lipid exhibited large inter-quartile ranges. The calcification had higher sound speed than the other plaque components at 1760-2000 ms(-1). The limitations here lay in the difficulties in the matching process caused by the inhomogeneity of the plaque material and shrinkage during the histological process. Future work may concentrate on more homogeneous material in order to derive sound speed data for separate components. Nevertheless, this study increases the known data ranges of the individual components within a plaque. This information may be used help to assess the mechanical properties and structural integrity and its associated vulnerability or risk of embolization in future diagnostic ultrasound techniques.
Collapse
|
36
|
Phantoms for Ultrasound Experimentation and Quality Control. THE PHANTOMS OF MEDICAL AND HEALTH PHYSICS 2014. [DOI: 10.1007/978-1-4614-8304-5_9] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/11/2023]
|
37
|
A non-exothermic cell-embedding tissue-mimicking material for studies of ultrasound-induced hyperthermia and drug release. Int J Hyperthermia 2013; 29:133-44. [PMID: 23406389 DOI: 10.3109/02656736.2012.762553] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Abstract
PURPOSE The present study aims to create and characterise a cell-embedding tissue-mimicking material (TMM) that has thermal and acoustic properties similar to liver tissue, in order to enable study and optimisation of protocols for ultrasound-induced hyperthermia and drug delivery. MATERIALS AND METHODS An agarose-based, cell-embedding TMM was iteratively developed and characterised. The acoustic properties (attenuation coefficient, speed of sound and cavitation threshold) and thermal response of the material were compared with those of fresh degassed liver tissue over a range of acoustic pressures and frequencies. A luminescence intensity assay was used to evaluate viability of HuH-7 cells in the material. The efficacy of ultrasound-mediated chemotherapeutic treatment in the material was tested by localised activation of low temperature thermally sensitive liposomes. Drug activation was measured by fluorescence microscopy. RESULTS Similar acoustic properties (attenuation coefficient, speed of sound) to liver tissue were achieved over the therapeutically relevant frequency range of 1-4 MHz and similar thermal response was achieved for acoustic pressures up to 4.8 MPa peak to peak (ppk) at 1.1 MHz. Above 4.8 MPa ppk cavitation enhanced heating occurred in the TMM. Drug release from low-temperature-sensitive liposomes was achieved with 4.4 MPa ppk 6-s exposures at 1.1 MHz and cell compatibility of the material was confirmed. CONCLUSIONS A platform for in vitro work for activation of thermally sensitive liposomes using high intensity focused ultrasound (HIFU)-induced hyperthermia was established. The TMM presents similar acoustic properties and thermal response to liver tissue over a broad range of ultrasound exposure conditions.
Collapse
|
38
|
Characterizing an agar/gelatin phantom for image guided dosing and feedback control of high-intensity focused ultrasound. ULTRASOUND IN MEDICINE & BIOLOGY 2013; 39:300-311. [PMID: 23245823 DOI: 10.1016/j.ultrasmedbio.2012.09.016] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/07/2011] [Revised: 09/12/2012] [Accepted: 09/22/2012] [Indexed: 06/01/2023]
Abstract
The temperature dependence of an agar/gelatin phantom was evaluated. The purpose was to predict the material property response to high-intensity focused ultrasound (HIFU) for developing ultrasound guided dosing and targeting feedback. Changes in attenuation, sound speed, shear modulus and thermal properties with temperature were examined from 20°C to 70°C for 3 weeks post-manufacture. The attenuation decreased with temperature by a power factor of 0.15. Thermal conductivity, diffusivity and specific heat all increased linearly with temperature for a total change of approximately 16%, 10% and 6%, respectively. Sound speed had a parabolic dependence on temperature similar to that of water. Initially, the shear modulus irreversibly declined with even a slight increase in temperature. Over time, the gel maintained its room temperature shear modulus with moderate heating. A stable phantom was achieved within 2 weeks post-manufacture that possessed quasi-reversible material properties up to nearly 55°C.
Collapse
|
39
|
The speed of sound and attenuation of an IEC agar-based tissue-mimicking material for high frequency ultrasound applications. ULTRASOUND IN MEDICINE & BIOLOGY 2012; 38:1262-70. [PMID: 22502881 PMCID: PMC3377968 DOI: 10.1016/j.ultrasmedbio.2012.02.030] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/14/2011] [Revised: 02/22/2012] [Accepted: 02/25/2012] [Indexed: 05/11/2023]
Abstract
This study characterized the acoustic properties of an International Electromechanical Commission (IEC) agar-based tissue mimicking material (TMM) at ultrasound frequencies in the range 10-47 MHz. A broadband reflection substitution technique was employed using two independent systems at 21°C ± 1°C. Using a commercially available preclinical ultrasound scanner and a scanning acoustic macroscope, the measured speeds of sound were 1547.4 ± 1.4 m∙s(-1) and 1548.0 ± 6.1 m∙s(-1), respectively, and were approximately constant over the frequency range. The measured attenuation (dB∙cm(-1)) was found to vary with frequency f (MHz) as 0.40f + 0.0076f(2). Using this polynomial equation and extrapolating to lower frequencies give values comparable to those published at lower frequencies and can estimate the attenuation of this TMM in the frequency range up to 47 MHz. This characterisation enhances understanding in the use of this TMM as a tissue equivalent material for high frequency ultrasound applications.
Collapse
|
40
|
Absolute backscatter coefficient estimates of tissue-mimicking phantoms in the 5-50 MHz frequency range. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2011; 130:737-43. [PMID: 21877789 PMCID: PMC3190655 DOI: 10.1121/1.3605669] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Absolute backscatter coefficients in tissue-mimicking phantoms were experimentally determined in the 5-50 MHz frequency range using a broadband technique. A focused broadband transducer from a commercial research system, the VisualSonics Vevo 770, was used with two tissue-mimicking phantoms. The phantoms differed regarding the thin layers covering their surfaces to prevent desiccation and regarding glass bead concentrations and diameter distributions. Ultrasound scanning of these phantoms was performed through the thin layer. To avoid signal saturation, the power spectra obtained from the backscattered radio frequency signals were calibrated by using the signal from a liquid planar reflector, a water-brominated hydrocarbon interface with acoustic impedance close to that of water. Experimental values of absolute backscatter coefficients were compared with those predicted by the Faran scattering model over the frequency range 5-50 MHz. The mean percent difference and standard deviation was 54% ± 45% for the phantom with a mean glass bead diameter of 5.40 μm and was 47% ± 28% for the phantom with 5.16 μm mean diameter beads.
Collapse
|
41
|
|
42
|
Comparative imaging study in ultrasound, MRI, CT, and DSA using a multimodality renal artery phantom. Med Phys 2011; 38:565-73. [DOI: 10.1118/1.3533674] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
|
43
|
Novel tissue mimicking materials for high frequency breast ultrasound phantoms. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:122-135. [PMID: 21084158 DOI: 10.1016/j.ultrasmedbio.2010.10.005] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/06/2010] [Revised: 09/22/2010] [Accepted: 10/07/2010] [Indexed: 05/30/2023]
Abstract
The development and acoustical characterisation of a range of novel agar-based tissue mimicking material (TMMs) for use in clinically relevant, quality assurance (QA) and anthropomorphic breast phantoms are presented. The novel agar-based TMMs described in this study are based on a comprehensive, systematic variation of the ingredients in the International Electrotechnical Commission (IEC) TMM. A novel, solid fat-mimicking material was also developed and acoustically characterised. Acoustical characterisation was carried out using an in-house scanning acoustic macroscope at low (7.5 MHz) and high frequencies (20 MHz), using the pulse-echo insertion technique. The speeds of sound range from 1490 to 1570 m. s(-1), attenuation coefficients range from 0.1 to 0.9 dB. cm(‑1). MHz(-1) and relative backscatter ranges from 0 to -20 dB. It was determined that tissues can be mimicked in terms of independently controllable speeds of sound and attenuation coefficients. These properties make these novel TMMs suitable for use in clinically relevant QA and anthropomorphic phantoms and would potentially be useful for other high frequency applications such as intravascular and small animal imaging.
Collapse
|
44
|
Development of a range of anatomically realistic renal artery flow phantoms. ULTRASOUND IN MEDICINE & BIOLOGY 2010; 36:1135-1144. [PMID: 20620700 DOI: 10.1016/j.ultrasmedbio.2010.04.017] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/22/2009] [Revised: 04/18/2010] [Accepted: 04/29/2010] [Indexed: 05/29/2023]
Abstract
Computer-aided modelling techniques were used to generate a range of anatomically realistic phantoms of the renal artery from medical images of a 64-slice CT data set acquired from a healthy volunteer. From these data, models of a normal healthy renal artery and diseased renal arteries with 30%, 50%, 70% and 85% stenoses were generated. Investment casting techniques and a low melting point alloy were used to create the vessels with varying degrees of stenosis. The use of novel inserts significantly reduced the time, materials and cost required in the fabrication of these anatomically realistic phantoms. To prevent residual metal remaining in the final phantom lumens a technique employing clingfilm was used to remove all molten metal from the lumen. These novel flow phantoms developed using efficient methods for producing vessels with various degrees of stenosis can provide a means of evaluation of current and emerging ultrasound technology.
Collapse
|
45
|
A review of tissue substitutes for ultrasound imaging. ULTRASOUND IN MEDICINE & BIOLOGY 2010; 36:861-73. [PMID: 20510184 DOI: 10.1016/j.ultrasmedbio.2010.02.012] [Citation(s) in RCA: 319] [Impact Index Per Article: 22.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/30/2009] [Revised: 02/03/2010] [Accepted: 02/22/2010] [Indexed: 05/05/2023]
Abstract
The characterization and calibration of ultrasound imaging systems requires tissue-mimicking phantoms with known acoustic properties, dimensions and internal features. Tissue phantoms are available commercially for a range of medical applications. However, commercial phantoms may not be suitable in ultrasound system design or for evaluation of novel imaging techniques. It is often desirable to have the ability to tailor acoustic properties and phantom configurations for specific applications. A multitude of tissue-mimicking materials and phantoms are described in the literature that have been created using a variety of materials and preparation techniques and that have modeled a range of biological systems. This paper reviews ultrasound tissue-mimicking materials and phantom fabrication techniques that have been developed over the past four decades, and describes the benefits and disadvantages of the processes. Both soft tissue and hard tissue substitutes are explored.
Collapse
|
46
|
The automated assessment of ultrasound scanner lateral and slice thickness resolution: use of the step response. ULTRASOUND IN MEDICINE & BIOLOGY 2009; 35:1525-1534. [PMID: 19560252 DOI: 10.1016/j.ultrasmedbio.2009.03.015] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/26/2008] [Revised: 03/13/2009] [Accepted: 03/19/2009] [Indexed: 05/28/2023]
Abstract
The imaging performance assessment of ultrasound scanners based on traditional phantoms is limited by repeatability, subjectivity and systematic errors giving low confidence in results. A new approach to the automated measurement of scanner resolution is described. The method utilises a step change in backscatter to derive resolution from the imaging system line spread function and has been used to calculate resolution in two dimensions as a continuous function of depth. Resolution data was used to calculate resolution integrals for both lateral and slice thickness independently. For resolution integral repeatability, analysis of variance showed no significant difference between operators (p=0.05) with intra and inter-operator repeatability (+/-1 standard deviation) of 1.5% and 1.5% for lateral resolution, respectively, and 2.6% and 3.3% for slice thickness, respectively. Low contrast penetration was also calculated automatically and the worst case operator repeatability was 1.3%. The acoustic properties of the phantom were validated. The possibility of extending the technique to axial resolution is discussed.
Collapse
|