1
|
Eiringhaus J, de Vries AL, Hohmann S, Böthig D, Müller-Leisse J, Hillmann HAK, Martens A, Zweigerdt R, Schrod A, Martin U, Duncker D, Gruh I, Veltmann C. Performance and feasibility of three different approaches for computer based semi-automated analysis of ventricular arrhythmias in telemetric long-term ECG in cynomolgus monkeys. J Pharmacol Toxicol Methods 2023; 124:107471. [PMID: 37690768 DOI: 10.1016/j.vascn.2023.107471] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2023] [Revised: 09/01/2023] [Accepted: 09/07/2023] [Indexed: 09/12/2023]
Abstract
Computer-based analysis of long-term electrocardiogram (ECG) monitoring in animal models represents a cost and time-consuming process as manual supervision is often performed to ensure accuracy in arrhythmia detection. Here, we investigate the performance and feasibility of three ECG interval analysis approaches A) attribute-based, B) attribute- and pattern recognition-based and C) combined approach with additional manual beat-to-beat analysis (gold standard) with regard to subsequent detection of ventricular arrhythmias (VA) and time consumption. ECG analysis was performed on ECG raw data of 5 male cynomolgus monkeys (1000 h total, 2 × 100 h per animal). Both approaches A and B overestimated the total number of arrhythmias compared to gold standard (+8.92% vs. +6.47%). With regard to correct classification of detected VA event numbers (accelerated idioventricular rhythms [AIVR], ventricular tachycardia [VT]) approach B revealed higher accuracy compared to approach A. Importantly, VA burden (% of time) was precisely depicted when using approach B (-1.13%), whereas approach A resulted in relevant undersensing of ventricular arrhythmias (-11.76%). Of note, approach A and B could be performed with significant less working time (-95% and - 91% working time) compared to gold standard. In sum, we show that a combination of attribute-based and pattern recognition analysis (approach B) can reproduce VA burden with acceptable accuracy without using manual supervision. Since this approach allowed analyses to be performed with distinct time saving it represents a valuable approach for cost and time efficient analysis of large preclinical ECG datasets.
Collapse
Affiliation(s)
- Jörg Eiringhaus
- Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Germany.
| | - Anna-Lena de Vries
- Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Germany
| | - Stephan Hohmann
- Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Germany.
| | - Dietmar Böthig
- Department of Pediatric Cardiology and Pediatric Intensive Care, Hannover Medical School, Germany.
| | - Johanna Müller-Leisse
- Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Germany.
| | - Henrike A K Hillmann
- Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Germany.
| | - Andreas Martens
- Department of Cardiac, Thoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Germany.
| | - Robert Zweigerdt
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiac, Thoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Germany.
| | | | - Ulrich Martin
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiac, Thoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Germany.
| | - David Duncker
- Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Germany.
| | - Ina Gruh
- Leibniz Research Laboratories for Biotechnology and Artificial Organs (LEBAO), Department of Cardiac, Thoracic, Transplantation, and Vascular Surgery, Hannover Medical School, Germany.
| | - Christian Veltmann
- Hannover Heart Rhythm Center, Department of Cardiology & Angiology, Hannover Medical School, Germany; Center for Electrophysiology Bremen, Bremen, Germany.
| |
Collapse
|
2
|
Boulay E, Miraucourt LS, Pugsley MK, Abernathy MM, Chui R, Dalton J, Demers M, Dybdal N, Gazaille E, Greiter-Wilke A, Hoffmann P, Huang H, LaDuke C, Norton K, Pierson JB, Reeves I, Roche B, Rossman EI, Schultze AE, Tang HM, Wisialowski T, Authier S. The incidence of spontaneous arrhythmias in telemetered beagle dogs, Göttingen Minipigs and Cynomolgus non-human primates: A HESI consortium retrospective analysis. J Pharmacol Toxicol Methods 2023; 121:107266. [PMID: 36963703 DOI: 10.1016/j.vascn.2023.107266] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2022] [Revised: 03/17/2023] [Accepted: 03/20/2023] [Indexed: 03/26/2023]
Abstract
INTRODUCTION Characterization of the incidence of spontaneous arrhythmias to identify possible drug-related effects is often an important part of the analysis in safety pharmacology studies using telemetry. METHODS A retrospective analysis in non-clinical species with and without telemetry transmitters was conducted. Electrocardiograms (24 h) from male and female beagle dogs (n = 131), Göttingen minipigs (n = 108) and cynomolgus non-human primates (NHP; n = 78) were analyzed. RESULTS Ventricular tachycardia (VT) was observed in 3% of the dogs but was absent in minipigs and NHPs. Ventricular fibrillation (VF) was not observed in the 3 species. Ventricular premature beats (VPBs) were more frequent during daytime and atrioventricular blocks (AVBs) were more frequent at night in all species. A limited number of animals exhibited a high arrhythmia frequency and there was no correlation between animals with higher frequency of an arrhythmia type and the frequency of other arrythmias in the same animals. Clinical chemistry or hematology parameters were not different with or without telemetry devices. NHP with a transmural left ventricular pressure (LVP) catheter exhibited a greater incidence of VPBs and PJCs compared to telemetry animals without LVP. DISCUSSION All species were similar with regards to the frequency of ventricular ectopic beats (26-46%) while the dog seemed to have more frequent junctional complexes and AVB compared to NHP and minipigs. Arrhythmia screening may be considered during pre-study evaluations, to exclude animals with abnormally high arrhythmia incidence.
Collapse
Affiliation(s)
- Emmanuel Boulay
- Charles River, Laval, Canada; Faculty of Veterinary Medicine, University of Montreal, QC, Canada
| | | | | | | | - Ray Chui
- Cardiovascular Analytics, Newbury Park, CA, USA
| | | | - Marjorie Demers
- Faculty of Veterinary Medicine, University of Montreal, QC, Canada
| | | | - Elissa Gazaille
- Faculty of Veterinary Medicine, University of Montreal, QC, Canada
| | - Andrea Greiter-Wilke
- Roche Pharma Research and Early Development, Pharmaceutical Sciences, Roche Innovation Center, Basel, Switzerland
| | | | | | | | | | | | | | | | | | | | | | | | - Simon Authier
- Charles River, Laval, Canada; Faculty of Veterinary Medicine, University of Montreal, QC, Canada.
| |
Collapse
|
3
|
Pereira PJS, Pugsley MK, Troncy E, Tan W, Pouliot M, Harper C, Prefontaine A, Easter A, Wallis R, Miraucourt L, Huang H, Accardi MV, Boulay E, Maghezzi MS, Authier S. Incidence of spontaneous arrhythmias in freely moving healthy untreated Sprague-Dawley rats. J Pharmacol Toxicol Methods 2019; 99:106589. [PMID: 31154034 DOI: 10.1016/j.vascn.2019.106589] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2019] [Revised: 05/07/2019] [Accepted: 05/25/2019] [Indexed: 12/18/2022]
Abstract
Spontaneous arrhythmia characterization in healthy rats can support interpretation when studying novel therapies. Male (n = 55) and female (n = 40) Sprague-Dawley rats with telemetry transmitters for a derivation II ECG. Arrhythmias were assessed from continuous ECG monitoring over a period of 24-48 h, and data analyzed using an automated detection algorithm with 100% manual over-read. While a total of 1825 spontaneous ventricular premature beats (VPB) were identified, only 7 rats (or 7.4%) did not present with any over the recording period. Spontaneous episode(s) of ventricular tachycardia (VT) were noted in males (27%) and females (3%). The incidence of VPB was significantly higher (p < 0.01) during the night time (7 pm-7 am) compared to daytime, while males presented with significantly (p < 0.001) more VPB than females. Most VPB were observed as single ectopic beats, followed by salvos (2 or 3 consecutive VPBs), and VT (i.e. 4 consecutive VPBs). Most VPBs were single premature ventricular contractions (PVCs) (57%), while the remaining were escape complexes (43%). Spontaneous premature junctional complexes (PJC) were also observed and were significantly more frequent during the night, and in males. Lastly, 596 episodes of spontaneous 2nd-degree atrioventricular (AV) block were identified and were significantly more frequent during the day time in males. Most 2nd-degree AV block episodes were Mobitz type I (57%), with a significantly (p < 0.05) higher incidence in males. This work emphasizes the importance of obtaining sufficient baseline data when undertaking arrhythmia analysis in safety study and provides a better understanding of both sex- and time- dependent effects of spontaneous arrhythmias in rats.
Collapse
Affiliation(s)
| | | | - Eric Troncy
- Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, QC, Canada
| | - Wendy Tan
- Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, QC, Canada
| | | | | | | | - Alison Easter
- Praxis Precision Medicines, Cambridge, MA, United States of America
| | - Rob Wallis
- Safety Pharmacology Consultant, London, United Kingdom
| | | | | | | | - Emmanuel Boulay
- Citoxlab, Laval, QC, Canada; Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, QC, Canada
| | | | - Simon Authier
- Citoxlab, Laval, QC, Canada; Faculty of Veterinary Medicine, Université de Montréal, St-Hyacinthe, QC, Canada.
| |
Collapse
|
4
|
Sala L, Bellin M, Mummery CL. Integrating cardiomyocytes from human pluripotent stem cells in safety pharmacology: has the time come? Br J Pharmacol 2017; 174:3749-3765. [PMID: 27641943 PMCID: PMC5647193 DOI: 10.1111/bph.13577] [Citation(s) in RCA: 91] [Impact Index Per Article: 11.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2016] [Revised: 07/27/2016] [Accepted: 08/11/2016] [Indexed: 12/20/2022] Open
Abstract
Cardiotoxicity is a severe side effect of drugs that induce structural or electrophysiological changes in heart muscle cells. As a result, the heart undergoes failure and potentially lethal arrhythmias. It is still a major reason for drug failure in preclinical and clinical phases of drug discovery. Current methods for predicting cardiotoxicity are based on guidelines that combine electrophysiological analysis of cell lines expressing ion channels ectopically in vitro with animal models and clinical trials. Although no new cases of drugs linked to lethal arrhythmias have been reported since the introduction of these guidelines in 2005, their limited predictive power likely means that potentially valuable drugs may not reach clinical practice. Human pluripotent stem cell-derived cardiomyocytes (hPSC-CMs) are now emerging as potentially more predictive alternatives, particularly for the early phases of preclinical research. However, these cells are phenotypically immature and culture and assay methods not standardized, which could be a hurdle to the development of predictive computational models and their implementation into the drug discovery pipeline, in contrast to the ambitions of the comprehensive pro-arrhythmia in vitro assay (CiPA) initiative. Here, we review present and future preclinical cardiotoxicity screening and suggest possible hPSC-CM-based strategies that may help to move the field forward. Coordinated efforts by basic scientists, companies and hPSC banks to standardize experimental conditions for generating reliable and reproducible safety indices will be helpful not only for cardiotoxicity prediction but also for precision medicine. LINKED ARTICLES This article is part of a themed section on New Insights into Cardiotoxicity Caused by Chemotherapeutic Agents. To view the other articles in this section visit http://onlinelibrary.wiley.com/doi/10.1111/bph.v174.21/issuetoc.
Collapse
Affiliation(s)
- Luca Sala
- Department of Anatomy and EmbryologyLeiden University Medical CenterLeidenZAThe Netherlands
| | - Milena Bellin
- Department of Anatomy and EmbryologyLeiden University Medical CenterLeidenZAThe Netherlands
| | - Christine L Mummery
- Department of Anatomy and EmbryologyLeiden University Medical CenterLeidenZAThe Netherlands
- Department of Applied Stem Cell TechnologiesUniversity of TwenteEnschedeThe Netherlands
| |
Collapse
|
5
|
Chebon S, Faes C, Cools F, Geys H. Models for zero-inflated, correlated count data with extra heterogeneity: when is it too complex? Stat Med 2017; 36:345-361. [PMID: 27734514 DOI: 10.1002/sim.7142] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/26/2015] [Revised: 07/30/2016] [Accepted: 09/16/2016] [Indexed: 11/10/2022]
Abstract
Statistical analysis of count data typically starts with a Poisson regression. However, in many real-life applications, it is observed that the variation in the counts is larger than the mean, and one needs to deal with the problem of overdispersion in the counts. Several factors may contribute to overdispersion: (1) unobserved heterogeneity due to missing covariates, (2) correlation between observations (such as in longitudinal studies), and (3) the occurrence of many zeros (more than expected from the Poisson distribution). In this paper, we discuss a model that allows one to explicitly take each of these factors into consideration. The aim of this paper is twofold: (1) investigate whether we can identify the cause of overdispersion via model selection, and (2) investigate the impact of a misspecification of the model on the power of a covariate. The paper is motivated by a study of the occurrence of drug-induced arrhythmia in beagle dogs based on electrocardiogram recordings, with the objective to evaluate the effect of potential drugs on the heartbeat irregularities. Copyright © 2016 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Sammy Chebon
- Interuniversity Institute for Biostatistics and Statistical Bioinformatics, Hasselt University, Diepenbeek, 3590, Belgium
| | - Christel Faes
- Interuniversity Institute for Biostatistics and Statistical Bioinformatics, Hasselt University, Diepenbeek, 3590, Belgium
| | - Frank Cools
- Janssen Pharmaceutica NV, Turnhoutseweg 30, Beerse, 2340, Belgium
| | - Helena Geys
- Interuniversity Institute for Biostatistics and Statistical Bioinformatics, Hasselt University, Diepenbeek, 3590, Belgium.,Janssen Pharmaceutica NV, Turnhoutseweg 30, Beerse, 2340, Belgium
| |
Collapse
|
6
|
Ruppert S, Vormberge T, Igl BW, Hoffmann M. ECG telemetry in conscious guinea pigs. J Pharmacol Toxicol Methods 2016; 81:88-98. [DOI: 10.1016/j.vascn.2016.04.013] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2016] [Revised: 04/07/2016] [Accepted: 04/22/2016] [Indexed: 12/26/2022]
|
7
|
Effects of telemetric epicardial leads and ventricular catheters on arrhythmia incidence in cynomolgus monkeys. J Pharmacol Toxicol Methods 2014; 69:167-76. [DOI: 10.1016/j.vascn.2013.11.001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2013] [Revised: 10/29/2013] [Accepted: 11/07/2013] [Indexed: 11/20/2022]
|
8
|
|
9
|
Pugsley MK, Curtis MJ. Methodological innovations expand the safety pharmacology horizon. J Pharmacol Toxicol Methods 2012; 66:59-62. [PMID: 22617368 DOI: 10.1016/j.vascn.2012.05.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2012] [Accepted: 05/11/2012] [Indexed: 02/08/2023]
Abstract
Almost uniquely in pharmacology, drug safety assessment is driven by the need for elaboration and validation of methods for detecting drug actions. This is the 9th consecutive year that the Journal of Pharmacological and Toxicological Methods (JPTM) has published themed issues arising from the annual meeting of the Safety Pharmacology Society (SPS). The SPS is now past its 10th year as a distinct (from pharmacology to toxicology) discipline that integrates safety pharmacologists from industry with those in academia and the various global regulatory authorities. The themes of the 2011 meeting were (i) the bridging of safety assessment of a new chemical entity (NCE) between all the parties involved, (ii) applied technologies and (iii) translation. This issue of JPTM reflects these themes. The content is informed by the regulatory guidance documents (S7A and S7B) that apply prior to first in human (FIH) studies, which emphasize the importance of seeking model validation. The manuscripts encompass a broad spectrum of safety pharmacology topics including application of state-of-the-art techniques for study conduct and data processing and evaluation. This includes some exciting novel integrated core battery study designs, refinements in hemodynamic assessment, arrhythmia analysis algorithms, and additionally an overview of safety immunopharmacology, and a brief survey discussing similarities and differences in business models that pharmaceutical companies employ in safety pharmacology, together with SPS recommendations on 'best practice' for the conduct of a non-clinical cardiovascular assessment of a NCE.
Collapse
|