1
|
Mitigation of viruses of concern and bacteriophage surrogates via common unit processes for water reuse: A meta-analysis. WATER RESEARCH 2024; 252:121242. [PMID: 38342066 DOI: 10.1016/j.watres.2024.121242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 01/26/2024] [Accepted: 01/30/2024] [Indexed: 02/13/2024]
Abstract
Water reuse is a growing global reality. In regulating water reuse, viruses have come to the fore as key pathogens due to high shedding rates, low infectious doses, and resilience to traditional wastewater treatments. To demonstrate the high log reductions required by emerging water reuse regulations, cost and practicality necessitate surrogates for viruses for use as challenge organisms in unit process evaluation and monitoring. Bacteriophage surrogates that are mitigated to the same or lesser extent than viruses of concern are routinely used for individual unit process testing. However, the behavior of these surrogates over a multi-barrier treatment train typical of water reuse has not been well-established. Toward this aim, we performed a meta-analysis of log reductions of common bacteriophage surrogates for five treatment processes typical of water reuse treatment trains: advanced oxidation processes, chlorination, membrane filtration, ozonation, and ultraviolet (UV) disinfection. Robust linear regression was applied to identify a range of doses consistent with a given log reduction of bacteriophages and viruses of concern for each treatment process. The results were used to determine relative conservatism of surrogates. We found that no one bacteriophage was a representative or conservative surrogate for viruses of concern across all multi-barrier treatments (encompassing multiple mechanisms of virus mitigation). Rather, a suite of bacteriophage surrogates provides both a representative range of inactivation and information about the effectiveness of individual processes within a treatment train. Based on the abundance of available data and diversity of virus treatability using these five key water reuse treatment processes, bacteriophages MS2, phiX174, and Qbeta were recommended as a core suite of surrogates for virus challenge testing.
Collapse
|
2
|
Inactivation Kinetics and Replication Cycle Inhibition of Coxsackievirus B5 by Free Chlorine. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:18690-18699. [PMID: 36946773 DOI: 10.1021/acs.est.2c09269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
The kinetics of coxsackievirus serotype B5 (CVB5) inactivation with free chlorine is characterized over a range of pH and temperature relevant to drinking water treatment with the primary goal of selecting experimental conditions used for assessing inactivation mechanisms. The inactivation kinetics identified in our study is similar to or slower than experimental data reported in the literature and thus provides a conservative representation of the kinetics of CVB5 inactivation for free chlorine that could be useful in developing future regulations for waterborne viral pathogens including adequate disinfection treatment for CVB5. Untreated and free chlorine-treated viruses, and host cells synchronized-infected with these viruses, are analyzed by a reverse transcription-quantitative polymerase chain reaction (RT-qPCR) method with the goal of quantitatively investigating the effect of free chlorine exposure on viral genome integrity, attachment to host cell, and viral genome replication. The inactivation kinetics observed results from a combination of hindering virus attachment to the host cell, inhibition of one or more subsequent steps of the replication cycle, and possibly genome damage.
Collapse
|
3
|
Chloramination of Nitromethane: Incomplete Chlorination and Unexpected Substitution Reaction. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:18856-18866. [PMID: 37191694 DOI: 10.1021/acs.est.2c09821] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/17/2023]
Abstract
Ozone is commonly used as a predisinfectant in potable water reuse treatment trains. Nitromethane was recently found as a ubiquitous ozone byproduct in wastewater, and the key intermediate toward chloropicrin during subsequent secondary disinfection of ozonated wastewater effluent with chlorine. However, many utilities have switched from free chlorine to chloramines as a secondary disinfectant. The reaction mechanism and kinetics of nitromethane transformation by chloramines, unlike those for free chlorine, are unknown. In this work, the kinetics, mechanism, and products of nitromethane chloramination were studied. The expected principal product was chloropicrin, because chloramines are commonly assumed to react similarly to, although more slowly than, free chlorine. Different molar yields of chloropicrin were observed under acidic, neutral, and basic conditions, and surprisingly, transformation products other than chloropicrin were found. Monochloronitromethane and dichloronitromethane were detected at basic pH, and the mass balance was initially poor at neutral pH. Much of the missing mass was later attributed to nitrate formation, from a newly identified pathway involving monochloramine reacting as a nucleophile rather than a halogenating agent, through a presumed SN2 mechanism. The study indicates that nitromethane chloramination, unlike chlorination, is likely to produce a range of products, whose speciation is a function of pH and reaction time.
Collapse
|
4
|
Inactivation of coxsackievirus B5 by free chlorine under conditions relevant to drinking water treatment. JOURNAL OF WATER AND HEALTH 2023; 21:1318-1324. [PMID: 37756198 PMCID: wh_2023_178 DOI: 10.2166/wh.2023.178] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/29/2023]
Abstract
Chlorine disinfection is commonly applied to inactivate pathogenic viruses in drinking water treatment plants. However, the role of water quality in chlorine disinfection of viruses has not been investigated thoughtfully. In this study, we investigated the inactivation efficiency of coxsackievirus B5 (CVB5) by free chlorine using actual water samples collected from four full-scale drinking water treatment plants in Japan under strict turbidity management (less than 0.14 NTU) over a 12-month period. It was found that chlorine disinfection of CVB5 might not be affected by water quality. Japanese turbidity management might play an indirect role in controlling the efficiency of chlorine disinfection.
Collapse
|
5
|
Continuous inactivation of human adenoviruses in water by a novel g-C 3N 4/WO 3/biochar memory photocatalyst under light-dark cycles. JOURNAL OF HAZARDOUS MATERIALS 2023; 442:130013. [PMID: 36155297 DOI: 10.1016/j.jhazmat.2022.130013] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/19/2022] [Revised: 08/31/2022] [Accepted: 09/15/2022] [Indexed: 06/16/2023]
Abstract
Viruses transmitted by water have raised considerable concerns for public health. A novel memory photocatalyst of g-C3N4/WO3/biochar was successfully developed for effective inactivation of human adenoviruses (HAdVs) in water, in which WO3 as an electron-storage reservoir and biochar as an electron shuttle is employed to synergistically improve photocatalytic activity of g-C3N4. The tertiary composite exhibited continuous photocatalytic performance for HAdVs inactivation without regrowth in water under light-dark cycles, i.e., ∼3.9-log inactivation under 6-h visible light irradiation and an additional ∼1.1-log inactivation under the following 6-h dark. The enhanced virucidal mechanism was attributed to the heterojunction formation and especially the electron-transfer pathway switching via biochar incorporation, contributing to electron transfer and storage in the light phase and then electron release in the dark phase, along with obviously increased generation of the virus-killing •OH radicals under light-dark cycles.
Collapse
|
6
|
Inactivation and genome damage of rotavirus and a human norovirus surrogate by monochloramine treatment and sequential application with UV. WATER RESEARCH 2022; 226:119309. [PMID: 36369682 DOI: 10.1016/j.watres.2022.119309] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/18/2022] [Revised: 10/25/2022] [Accepted: 10/27/2022] [Indexed: 06/16/2023]
Abstract
The inactivation efficacy by monochloramine for disinfecting gastroenteritis-causing rotaviruses (RV) and Tulane viruses (TV), a surrogate for noroviruses, were evaluated in this study. In addition, the strategies for improving the disinfection efficiency of monochloramine by raising the temperature and sequentially implementing UV irradiation were investigated. The results showed that monochloramine was more effective in the inactivation of TV than RV. Additionally, the inactivation rate constants of RV and TV by monochloramine at 35 °C were improved approximately by 46% and 100%, respectively, compared to those at 25 °C. Moreover, applying UV irradiation before monochloramine enhanced the inactivation efficacy of RV and TV by 63% and 72% compared to monochloramine alone (UV: 6 mJ/cm2, NH2Cl: 60 ppm × min). Furthermore, the synergistic effect was observed during the RV inactivation by the sequential process. Especially, higher than 0.5 log10 reductions of RV VP1 genome contributed to the synergistic effect in sequential treatment, while less than 0.1 log10 reductions of RV VP1 genome were observed during UV alone (13 mJ/cm2) or monochloramine alone (94 ppm × min). The genome damage might be the primary mechanism of generating synergy in sequential treatment for the inactivation of RV. By comparison, no synergistic effect was discovered for the inactivation of TV due to high susceptibility to monochloramine and UV. The findings on the inactivation efficacy and mechanism for improvement will contribute to a wide application of monochloramine for virus inactivation in water treatment and distribution systems.
Collapse
|
7
|
A review on disinfection methods for inactivation of waterborne viruses. Front Microbiol 2022; 13:991856. [PMID: 36212890 PMCID: PMC9539188 DOI: 10.3389/fmicb.2022.991856] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 08/29/2022] [Indexed: 11/13/2022] Open
Abstract
Water contamination is a global health problem, and the need for safe water is ever-growing due to the public health implications of unsafe water. Contaminated water could contain pathogenic bacteria, protozoa, and viruses that are implicated in several debilitating human diseases. The prevalence and survival of waterborne viruses differ from bacteria and other waterborne microorganisms. In addition, viruses are responsible for more severe waterborne diseases such as gastroenteritis, myocarditis, and encephalitis among others, hence the need for dedicated attention to viral inactivation. Disinfection is vital to water treatment because it removes pathogens, including viruses. The commonly used methods and techniques of disinfection for viral inactivation in water comprise physical disinfection such as membrane filtration, ultraviolet (UV) irradiation, and conventional chemical processes such as chlorine, monochloramine, chlorine dioxide, and ozone among others. However, the production of disinfection by-products (DBPs) that accompanies chemical methods of disinfection is an issue of great concern due to the increase in the risks of harm to humans, for example, the development of cancer of the bladder and adverse reproductive outcomes. Therefore, this review examines the conventional disinfection approaches alongside emerging disinfection technologies, such as photocatalytic disinfection, cavitation, and electrochemical disinfection. Moreover, the merits, limitations, and log reduction values (LRVs) of the different disinfection methods discussed were compared concerning virus removal efficiency. Future research needs to merge single disinfection techniques into one to achieve improved viral disinfection, and the development of medicinal plant-based materials as disinfectants due to their antimicrobial and safety benefits to avoid toxicity is also highlighted.
Collapse
|
8
|
Assessment of the Impact on Human Health of the Presence of Norovirus in Bivalve Molluscs: What Data Do We Miss? Foods 2021; 10:foods10102444. [PMID: 34681492 PMCID: PMC8535557 DOI: 10.3390/foods10102444] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2021] [Revised: 10/08/2021] [Accepted: 10/12/2021] [Indexed: 01/22/2023] Open
Abstract
In the latest One Health ECDC EFSA technical report, Norovirus in fish and fishery products have been listed as the agent/food pair causing the highest number of strong-evidence outbreaks in the EU in 2019. This review aims to identify data gaps that must be filled in order to increase knowledge on Norovirus in bivalve molluscs, perform a risk assessment and rank the key mitigation strategies for this biological hazard, which is relevant to public health. Virologic determinations are not included in any of the food safety and process hygiene microbiologic criteria reflected in the current European regulations. In addition, the Escherichia coli-based indices of acceptable faecal contamination for primary production, as well as the food safety criteria, do not appear sufficient to indicate the extent of Norovirus contamination. The qualitative risk assessment data collected in this review suggests that bivalve molluscs present a high risk to human health for Norovirus only when consumed raw or when insufficiently cooked. On the contrary, the risk can be considered negligible when they are cooked at a high temperature, while information is still scarce for non-thermal treatments.
Collapse
|
9
|
The occurrence and control of waterborne viruses in drinking water treatment: A review. CHEMOSPHERE 2021; 281:130728. [PMID: 34010719 PMCID: PMC8084847 DOI: 10.1016/j.chemosphere.2021.130728] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2021] [Revised: 04/21/2021] [Accepted: 04/25/2021] [Indexed: 05/04/2023]
Abstract
As the coronavirus disease 2019 continues to spread globally, its culprit, the severe acute respiratory syndrome coronavirus 2 has been brought under scrutiny. In addition to inhalation transmission, the possible fecal-oral viral transmission via water/wastewater has also been brought under the spotlight, necessitating a timely global review on the current knowledge about waterborne viruses in drinking water treatment system - the very barrier that intercepts waterborne pathogens to terminal water users. In this article we reviewed the occurrence, concentration methods, and control strategies, also, treatment performance on waterborne viruses during drinking water treatment were summarized. Additionally, we emphasized the potential of applying the quantitative microbial risk assessment to guide drinking water treatment to mitigate the viral exposure risks, especially when the unregulated novel viral pathogens are of concern. This review paves road for better control of viruses at drinking water treatment plants to protect public health.
Collapse
|
10
|
A probabilistic model for assessing uncertainty and sensitivity in the prediction of monochloramine loss in French river waters. WATER RESEARCH 2021; 202:117383. [PMID: 34237692 DOI: 10.1016/j.watres.2021.117383] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 06/03/2021] [Accepted: 06/20/2021] [Indexed: 06/13/2023]
Abstract
Monochloramine (NH2Cl) is increasingly used as alternative disinfectant to free chlorine in industrial plants. After use in cooling systems, the waters are released to the environment and residual NH2Cl may be discharged into the receiving waters. As NH2Cl is suspected to exhibit toxicity towards aquatic organisms, a proper risk assessment of its occurrence in environmental waters is needed to prevent adverse effects on wildlife. For this purpose, a comprehensive model simulating monochloramine loss in natural riverine waters was developed. This model incorporates the following processes: (i) autodecomposition; (ii) reaction with nitrite and bromide; (iii) oxidation with Dissolved Organic Carbon (DOC); (iv) oxidation with organic fraction of Suspended Particulate Matter (SPM); (v) reactions in bottom sediments and (vi) volatilization. The model was also designed to conduct uncertainty and sensitivity analysis. It was tested on several French rivers submitted to discharges of monochloraminated effluents and on several seasonal conditions. Uncertainty analysis allowed evaluation of confidence intervals related to NH2Cl half-lives in natural waters. It was shown that simulation intervals are in good agreement with experimental data obtained on the same rivers. Sensitivity analysis using an EFAST variance decomposition approach allowed identification of the most influential parameters on half-life determination. It was shown that the kinetic rate describing rapid reaction of NH2Cl with DOC is by far the most sensitive parameter, demonstrating the predominance of such reactions in the loss process. Variables or parameters involved in temperature dependence (temperature and activation energy) can also significantly influence model results. To a lesser extent, wind velocity is the most sensitive parameter explaining uncertainty in the prediction of volatilization, with a high level of interactions with other parameters, showing that loss through volatilization can be essential in some specific conditions only. This study then identified the most important research priorities for improving the prediction of NH2Cl half-lives in natural rivers.
Collapse
|
11
|
Impact of the Heterogeneity in Free Chlorine, UV 254, and Ozone Susceptibilities Among Coxsackievirus B5 on the Prediction of the Overall Inactivation Efficiency. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2021; 55:3156-3164. [PMID: 33583178 DOI: 10.1021/acs.est.0c07796] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/12/2023]
Abstract
The disinfection susceptibilities of viruses vary even among variants, yet the inactivation efficiency of a certain virus genotype, species, or genus was determined based on the susceptibility of its laboratory strain. The objectives were to evaluate the variability in susceptibilities to free chlorine, UV254, and ozone among 13 variants of coxsackievirus B5 (CVB5) and develop the model allowing for predicting the overall inactivation of heterogeneous CVB5. Our results showed that the susceptibilities differed by up to 3.4-fold, 1.3-fold, and 1.8-fold in free chlorine, UV254, and ozone, respectively. CVB5 in genogroup B exhibited significantly lower susceptibility to free chlorine and ozone than genogroup A, where the laboratory strain, Faulkner, belongs. The capsid protein in genogroup B contained a lower number of sulfur-containing amino acids, readily reactive to oxidants. We reformulated the Chick-Watson model by incorporating the probability distributions of inactivation rate constants to capture the heterogeneity. This expanded Chick-Watson model indicated that up to 4.2-fold larger free chlorine CT is required to achieve 6-log inactivation of CVB5 than the prediction by the Faulkner strain. Therefore, it is recommended to incorporate the variation in disinfection susceptibilities for predicting the overall inactivation of a certain type of viruses.
Collapse
|
12
|
Elucidating sulfate radical-mediated disinfection profiles and mechanisms of Escherichia coli and Enterococcus faecalis in municipal wastewater. WATER RESEARCH 2020; 173:115552. [PMID: 32062220 DOI: 10.1016/j.watres.2020.115552] [Citation(s) in RCA: 33] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/13/2019] [Revised: 01/22/2020] [Accepted: 01/25/2020] [Indexed: 06/10/2023]
Abstract
Practical applications of disinfection technologies for engineered waters require an in‒depth understanding of disinfection profiles and mechanisms of pathogenic bacteria in a complex matrix. This study investigated the inactivation of E. coli and E. faecalis by SO4•-, an emerging advanced disinfectant, in ultrapure water (UPW) and wastewater effluent (WE). Based on the bacterial inactivation kinetics in UPW in a zerovalent iron/peroxydisulfate system, the second order rate constants (k) for SO4•- reacting with E. coli and E. faecalis were measured to be (1.39 ± 0.1) × 109 M-1 s-1 and (6.71 ± 0.1) × 109 M-1 s-1, respectively. The morphological images of both bacteria by the scanning electron microscope indicated that SO4•- initiates oxidative reactions on the wall/membranes, causing their irreversible damage, ultimately affecting membrane permeability and physiological functions. To profile the inactivation kinetics of two strains of bacteria in WE matrix, a mechanistic process‒based model with the obtained k values was developed. Sensitivity and uncertainty analyses indicated that the key parameters for the model predictions were the concentrations of halide ions (i.e., Br- and Cl-) in WE and their k values reacting with SO4•- accounting for >80% of uncertainty or variance expected in predicted bacterial inactivation. This model allows precise estimation of required disinfectant dose even in complex water matrices, shedding lights on the extension of application of SO4•-‒based technology in wastewater treatments.
Collapse
|
13
|
Determination of monochloramine dissipation kinetics in various surface water qualities under relevant environmental conditions - Consequences regarding environmental risk assessment. THE SCIENCE OF THE TOTAL ENVIRONMENT 2019; 685:542-554. [PMID: 31181531 DOI: 10.1016/j.scitotenv.2019.05.364] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/15/2019] [Revised: 05/23/2019] [Accepted: 05/23/2019] [Indexed: 06/09/2023]
Abstract
A total 190 experiments were performed to study the dissipation kinetics of monochloramine (NH2Cl, CAS no 10599-90-3) in surface water samples from six rivers (Loire, Rhône, Meuse, Garonne, Seine and Moselle) and an artificial reservoir (Mirgenbach), all located in France. Experiments were conducted in an open reactor, under relevant controlled environmental conditions. The impact of various parameters such as initial NH2Cl concentration, temperature, pH, presence of sediments, sampling site and collection period was investigated. It was found that NH2Cl dissipated rapidly without any lag phase, and that decay follows an apparent first-order kinetics (r2 > 0.99). Presence of sediment greatly accelerated decay. Half-lives were generally <1 h in river water in presence of natural sediment, but of several hours without sediment. The impact of pH was low for the normal river water pH range. However, increase in temperature significantly accelerated decay. The combination of high initial NH2Cl concentrations and elevated temperatures generally gives half-lives similar to those obtained at lower temperatures and lower concentrations. Short half-lives (0.06 to 1.50 h) were found in all the surface waters examined, regardless of geographic location of sampling site or collection period, indicating no temporal or site-specific effects on NH2Cl dissipation. Decay was slightly faster at lower initial concentrations, which supports extrapolation of half-lives measured in this study to a wide range of environmental concentrations. It can thus be assumed that NH2Cl degradation in river and reservoir waters is mainly determined by presence of sediments and temperature.
Collapse
|
14
|
Chlorine inactivation of coxsackievirus B5 in recycled water destined for non-potable reuse. JOURNAL OF WATER AND HEALTH 2019; 17:124-136. [PMID: 30758309 DOI: 10.2166/wh.2018.393] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/28/2023]
Abstract
Currently guidelines for disinfection of water with free chlorine, while primarily developed for potable water, are often used for virus disinfection of nitrified recycled water of >1 NTU (Nephelometric Turbidity Unit). More information is needed on the disinfection efficacy of free chlorine for viruses in waters of varying turbidity and pH due to significant reuse of treated wastewater of varying quality. In this study, disinfection efficacy in nitrified/denitrified activated sludge treated wastewater was investigated for coxsackievirus B5 (CB5), an enterovirus known to be highly resistant to free chlorine. The required chlorine contact times (CT) values (mg.min/L) for inactivation of CB5 were established in treated wastewater at 10 °C and of varying turbidity (0.2, 2, 5 and 20 NTU) and pH (7, 8 and 9). CTs were calculated to achieve 1 to 4 log10 inactivation. Robust data is presented in support of the chlorine CT values required to inactivate a chlorine-resistant virus in a range of turbidities and pHs in treated wastewaters. The testing method used a conservative approach and the data presented have been used to develop the free chlorine virus inactivation guildelines for recycled water in Victoria and South Australia, Australia.
Collapse
|
15
|
Impacts of virus processing on human norovirus GI and GII persistence during disinfection of municipal secondary wastewater effluent. WATER RESEARCH 2018; 134:1-12. [PMID: 29407643 DOI: 10.1016/j.watres.2018.01.053] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2017] [Revised: 01/20/2018] [Accepted: 01/22/2018] [Indexed: 05/03/2023]
Abstract
Noroviruses cause significant global health burdens and waterborne transmission is a known exposure pathway. Chlorination is the most common method of disinfection for water and wastewater worldwide. The purpose of this study was to investigate the underlying causes for discrepancies in human norovirus (hNoV) resistance to free chlorine that have been previously published, and to assess hNoV GI and GII persistence during disinfection of municipal secondary wastewater (WW) effluent. Our results reveal that choice of hNoV purification methodology prior to seeding the viruses in an experimental water matrix influences disinfection outcomes in treatment studies. Common hNoV purification processes such as solvent extraction and 0.45-μm filtration were ineffective in removing high levels of organics introduced into water or wastewater samples when seeding norovirus positive stool. These methods resulted in experimental water matrices receiving an additional 190 mg/L as Cl2 of 15-s chlorine demand and approximately 440 mg/L as Cl2 of 30-min chlorine demand due to seeding norovirus positive stool at 1% w/v. These high organic loads impact experimental water chemistry and bias estimations of hNoV persistence. Advanced purification of norovirus positive stool using sucrose cushion ultracentrifugation and ultrafiltration reduced 15-s chlorine demands by 99% and TOC by 93% for loose (i.e. unformed diarrhea) stools. Using these methods, hNoV GI and GII persistence was investigated during free chlorination of municipal WW. A suite five of kinetic inactivation models was fit to viral reverse transcription-qPCR reduction data, and model predicted CT values for 1, 2, and 3 log10 reduction of hNoV GI in municipal WW by free chlorine were 0.3, 2.1, and 7.8 mg-min/L, respectively. Model predicted CT values for reduction of hNoV GII in WW were 0.4, 2.0, and 7.0 mg-min/L, respectively. These results indicate that current WW treatment plant disinfection practices employing free chlorine are likely protective for public health with regards to noroviruses, and will achieve at least 3-log reduction of hNoV GI and GII RNA despite previous reports of high hNoV resistance.
Collapse
|
16
|
Variability in Disinfection Resistance between Currently Circulating Enterovirus B Serotypes and Strains. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2018; 52:3696-3705. [PMID: 29466658 DOI: 10.1021/acs.est.8b00851] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/22/2023]
Abstract
The susceptibility of waterborne viruses to disinfection is known to vary between viruses and even between closely related strains, yet the extent of this variation is not known. Here, different enteroviruses (six strains of coxsackievirus B5, two strains of coxsackievirus B4 and one strain of coxackievirus B1) were isolated from wastewater and inactivated by UV254, sunlight, free chlorine (FC), chlorine dioxide (ClO2), and heat. Inactivation kinetics of these isolates were compared with those of laboratory enterovirus strains (CVB5 Faulkner and echovirus 11 Gregory) and MS2 bacteriophage. FC exhibited the greatest (10-fold) variability in inactivation kinetics between different strains, whereas inactivation by UV254 differed only subtly. The variability in inactivation kinetics was greater between serotypes than it was among the seven strains of the CVB5 serotype. MS2 was a conservative surrogate of enterovirus inactivation by UV254, sunlight, or heat but frequently underestimated the disinfection requirements for FC and ClO2. Similarly, laboratory strains did not always reflect the inactivation behavior of the environmental isolates. Overall, there was considerable variability in inactivation kinetics among and within enteroviruses serotypes, as well as between laboratory and environmental isolates. We therefore recommend that future disinfection studies include a variety of serotypes and environmental isolates.
Collapse
|
17
|
Inactivation of Human Norovirus Genogroups I and II and Surrogates by Free Chlorine in Postharvest Leafy Green Wash Water. Appl Environ Microbiol 2017; 83:e01457-17. [PMID: 28887415 PMCID: PMC5666131 DOI: 10.1128/aem.01457-17] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/07/2017] [Accepted: 09/06/2017] [Indexed: 11/20/2022] Open
Abstract
Human noroviruses (hNoVs) are a known public health concern associated with the consumption of leafy green vegetables. While a number of studies have investigated pathogen reduction on the surfaces of leafy greens during the postharvest washing process, there remains a paucity of data on the level of treatment needed to inactivate viruses in the wash water, which is critical for preventing cross-contamination. The objective of this study was to quantify the susceptibility of hNoV genotype I (GI), hNoV GII, murine norovirus (MNV), and bacteriophage MS2 to free chlorine in whole leaf, chopped romaine, and shredded iceberg lettuce industrial leafy green wash waters, each sampled three times over a 4-month period. A suite of kinetic inactivation models was fit to the viral reduction data to aid in quantification of concentration-time (CT) values. Results indicate that 3-log10 infectivity reduction was achieved at CT values of less than 0.2 mg · min/liter for MNV and 2.5 mg · min/liter for MS2 in all wash water types. CT values for 2-log10 molecular reduction of hNoV GI in whole leaf and chopped romaine wash waters were 1.5 and 0.9 mg · min/liter, respectively. For hNoV GII, CT values were 13.0 and 7.5 mg · min/liter, respectively. In shredded iceberg wash water, 3-log10 molecular reduction was not observed for any virus over the time course of experiments. These findings demonstrate that noroviruses may exhibit genogroup-dependent resistance to free chlorine and emphasize the importance of distinguishing between genogroups in hNoV persistence studies.IMPORTANCE Postharvest washing of millions of pounds of leafy greens is performed daily in industrial processing facilities with the intention of removing dirt, debris, and pathogenic microorganisms prior to packaging. Modest inactivation of pathogenic microorganisms (less than 2 log10) is known to occur on the surfaces of leafy greens during washing. Therefore, the primary purpose of the sanitizing agent is to maintain microbial quality of postharvest processing water in order to limit cross-contamination. This study modeled viral inactivation data and quantified the free-chlorine CT values that processing facilities must meet in order to achieve the desired level of hNoV GI and GII reduction. Disinfection experiments were conducted in industrial leafy green wash water collected from a full-scale fresh produce processing facility in the United States, and hNoV GI and GII results were compared with surrogate molecular and infectivity data.
Collapse
|
18
|
Reduction of Human Norovirus GI, GII, and Surrogates by Peracetic Acid and Monochloramine in Municipal Secondary Wastewater Effluent. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:11918-11927. [PMID: 28910089 DOI: 10.1021/acs.est.7b02954] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
The objective of this study was to characterize human norovirus (hNoV) GI and GII reductions during disinfection by peracetic acid (PAA) and monochloramine in secondary wastewater (WW) and phosphate buffer (PB) as assessed by reverse transcription-qPCR (RT-qPCR). Infectivity and RT-qPCR reductions are also presented for surrogate viruses murine norovirus (MNV) and bacteriophage MS2 under identical experimental conditions to aid in interpretation of hNoV molecular data. In WW, RT-qPCR reductions were less than 0.5 log10 for all viruses at concentration-time (CT) values up to 450 mg-min/L except for hNoV GI, where 1 log10 reduction was observed at CT values of less than 50 mg-min/L for monochloramine and 200 mg-min/L for PAA. In PB, hNoV GI and MNV exhibited comparable resistance to PAA and monochloramine with CT values for 2 log10 RT-qPCR reduction between 300 and 360 mg-min/L. Less than 1 log10 reduction was observed for MS2 and hNoV GII in PB at CT values for both disinfectants up to 450 mg-min/L. Our results indicate that hNoVs exhibit genogroup dependent resistance and that disinfection practices targeting hNoV GII will result in equivalent or greater reductions for hNoV GI. These data provide valuable comparisons between hNoV and surrogate molecular signals that can begin the process of informing regulators and engineers on WW treatment plant design and operational practices necessary to inactivate hNoVs.
Collapse
|
19
|
Comparative Inactivation of Murine Norovirus and MS2 Bacteriophage by Peracetic Acid and Monochloramine in Municipal Secondary Wastewater Effluent. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2017; 51:2972-2981. [PMID: 28165216 DOI: 10.1021/acs.est.6b05529] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Chlorination has long been used for disinfection of municipal wastewater (MWW) effluent while the use peracetic acid (PAA) has been proposed more recently in the United States. Previous work has demonstrated the bactericidal effectiveness of PAA and monochloramine in wastewater, but limited information is available for viruses, especially ones of mammalian origin (e.g., norovirus). Therefore, a comparative assessment was performed of the virucidal efficacy of PAA and monochloramine against murine norovirus (MNV) and MS2 bacteriophage in secondary effluent MWW and phosphate buffer (PB). A suite of inactivation kinetic models was fit to the viral inactivation data. Predicted concentration-time (CT) values for 1-log10 MS2 reduction by PAA and monochloramine in MWW were 1254 and 1228 mg-min/L, respectively. The 1-, 2-, and 3-log10 model predicted CT values for MNV viral reduction in MWW were 32, 47, and 69 mg-min/L for PAA and 6, 13, and 28 mg-min/L for monochloramine, respectively. Wastewater treatment plant disinfection practices informed by MS2 inactivation data will likely be protective for public health but may overestimate CT values for reduction of MNV. Additionally, equivalent CT values in PB resulted in greater viral reduction which indicate that viral inactivation data in laboratory grade water may not be generalizable to MWW applications.
Collapse
|
20
|
From Lab to Lake - Evaluation of Current Molecular Methods for the Detection of Infectious Enteric Viruses in Complex Water Matrices in an Urban Area. PLoS One 2016; 11:e0167105. [PMID: 27880820 PMCID: PMC5120873 DOI: 10.1371/journal.pone.0167105] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Accepted: 11/07/2016] [Indexed: 11/22/2022] Open
Abstract
Quantitative PCR methods are commonly used to monitor enteric viruses in the aquatic environment because of their high sensitivity, short reaction times and relatively low operational cost. However, conclusions for public health drawn from results of such molecular techniques are limited due to their inability to determine viral infectivity. Ethidium monoazide (EMA) and propidium monoazide (PMA) are capable to penetrate the damaged or compromised capsid of the inactivated viruses and bind to the viral nucleic acids. We assessed whether dye treatment is a suitable approach to improve the ability of qPCR to distinguish between infectious and non-infectious human adenovirus, enterovirus and rotavirus A in surface water of an urban river and sewage before and after UV disinfection. Like the gold standard of cell culture assays, pretreatment EMA-/PMA-qPCR succeeded in removing false positive results which would lead to an overestimation of the viral load if only qPCR of the environmental samples was considered. A dye pretreatment could therefore provide a rapid and relatively inexpensive tool to improve the efficacy of molecular quantification methods in regards to viral infectivity.
Collapse
|
21
|
Removal and inactivation of virus by drinking water treatment in the presence of bromide or iodide. J WATER CHEM TECHNO+ 2015. [DOI: 10.3103/s1063455x15020095] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
22
|
Selective and trace determination of monochloramine in river water by chemical derivatization and liquid chromatography/tandem mass spectrometry analysis. Talanta 2015; 140:189-197. [PMID: 26048841 DOI: 10.1016/j.talanta.2015.03.043] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2014] [Revised: 03/16/2015] [Accepted: 03/22/2015] [Indexed: 11/25/2022]
Abstract
Monochloramine (MCA) may enter the aquatic environment through three main sources: wastewater treatment plant effluents, industrial effluents and thermal power plant wastes. Up to date, there are no available data about the concentration levels of this chemical in river water due to lack of appropriate analytical methods. Therefore, sensitive and selective analytical methods for monochloramine analysis in river water are required to evaluate its environmental fate and its effects on aquatic ecosystems. Thus, in this study we describe a highly specific and sensitive method for monochloramine determination in river water. This method combines chemical derivatization of monochloramine into indophenol followed by liquid chromatography coupled to electrospray ionisation-tandem mass spectrometry (LC-ESI-MS/MS) analysis. Two precursor-to-product ion transitions were monitored (200→127 and 200→154) in positive ionisation mode, fulfilling the criteria of selectivity, in accordance with the European Legislation requirements (decision 2002/657/EC). Ion structures and fragmentation mechanisms have been proposed to explain the selected transitions. Linearity range, accuracy and precision of the method have been assessed according to the French method validation standard NF T90-210. Detecting the derivatized monochloramine (indophenol) in Multiple Reaction Monitoring (MRM) mode provided a limit of quantification of 40 ng L(-1) equivalent monochloramine. Applied to Loire river water (France), the developed method occasionally detected monochloramine at concentrations less than 300 ng L(-1), which could be explained by punctual discharges of water containing active chlorine upstream of the sampling point. Indeed, it is widely reported in the literature that the addition of chlorine to water containing ammonia (e.g., wastewater effluents and river water) may result in the instantaneous formation of monochloramine. The proposed method is a powerful tool that can be used in environmental research (e.g., assessment of environmental fate and generating of ecotoxicological data) as well as in research studies concerning the evaluation of water disinfection efficiency; but it is not currently appropriate for routine use in industrial applications given the complexity of the procedure, the instability of indophenol and the use of certain toxic reagents.
Collapse
|
23
|
Control of Foodborne Viruses at Retail. RETAIL FOOD SAFETY 2014. [PMCID: PMC7122658 DOI: 10.1007/978-1-4939-1550-7_6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
24
|
Subtle differences in virus composition affect disinfection kinetics and mechanisms. Appl Environ Microbiol 2013; 79:3455-67. [PMID: 23542618 DOI: 10.1128/aem.00663-13] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Viral disinfection kinetics have been studied in depth, but the molecular-level inactivation mechanisms are not understood. Consequently, it is difficult to predict the disinfection behavior of nonculturable viruses, even when related, culturable viruses are available. The objective of this work was to determine how small differences in the composition of the viral genome and proteins impact disinfection. To this end, we investigated the inactivation of three related bacteriophages (MS2, fr, and GA) by UV254, singlet oxygen ((1)O2), free chlorine (FC), and chlorine dioxide (ClO2). Genome damage was quantified by PCR, and protein damage was assessed by quantitative matrix-assisted laser desorption ionization (MALDI) mass spectrometry. ClO2 caused great variability in the inactivation kinetics between viruses and was the only treatment that did not induce genome damage. The inactivation kinetics were similar for all viruses when treated with disinfectants possessing a genome-damaging component (FC, (1)O2, and UV254). On the protein level, UV254 subtly damaged MS2 and fr capsid proteins, whereas GA's capsid remained intact. (1)O2 oxidized a methionine residue in MS2 but did not affect the other two viruses. In contrast, FC and ClO2 rapidly degraded the capsid proteins of all three viruses. Protein composition alone could not explain the observed degradation trends; instead, molecular dynamics simulations indicated that degradation is dictated by the solvent-accessible surface area of individual amino acids. Finally, despite the similarities of the three viruses investigated, their mode of inactivation by a single disinfectant varied. This explains why closely related viruses can exhibit drastically different inactivation kinetics.
Collapse
|
25
|
Disinfection: is it time to reconsider Spaulding? J Hosp Infect 2011; 78:163-70. [DOI: 10.1016/j.jhin.2011.05.002] [Citation(s) in RCA: 55] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2011] [Accepted: 05/06/2011] [Indexed: 10/18/2022]
|