1
|
Moungmaithong S, Lam MSN, Kwan AHW, Wong STK, Tse AWT, Sahota DS, Tai STA, Poon LCY. Prediction of labour outcomes using prelabour computerised cardiotocogram and maternal and fetal Doppler indices: A prospective cohort study. BJOG 2024; 131:472-482. [PMID: 37718558 DOI: 10.1111/1471-0528.17669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2023] [Revised: 08/04/2023] [Accepted: 09/02/2023] [Indexed: 09/19/2023]
Abstract
OBJECTIVES To investigate the association and the potential value of prelabour fetal heart rate short-term variability (STV) determined by computerised cardiotocography (cCTG) and maternal and fetal Doppler in predicting labour outcomes. DESIGN Prospective cohort study. SETTING The Prince of Wales Hospital, a tertiary maternity unit, in Hong Kong SAR. POPULATION Women with a term singleton pregnancy in latent phase of labour or before labour induction were recruited during May 2019-November 2021. METHODS Prelabour ultrasonographic assessment of fetal growth, Doppler velocimetry and prelabour cCTG monitoring including Dawes-Redman CTG analysis were registered shortly before induction of labour or during the latent phase of spontaneous labour. MAIN OUTCOME MEASURES Umbilical cord arterial pH, emergency delivery due to pathological CTG during labour and neonatal intensive care unit (NICU)/special care baby unit (SCBU) admission. RESULTS Of the 470 pregnant women invited to participate in the study, 440 women provided informed consent and a total of 400 participants were included for further analysis. Thirty-four (8.5%) participants underwent emergency delivery for pathological CTG during labour. A total of 6 (1.50%) and 148 (37.00%) newborns required NICU and SCBU admission, respectively. Middle cerebral artery pulsatility index (MCA-PI) and MCA-PI z-score were significantly lower in pregnancies that required emergency delivery for pathological CTG during labour compared with those that did not (1.23 [1.07-1.40] versus 1.40 [1.22-1.64], p = 0.002; and 0.55 ± 1.07 vs. 0.12 ± 1.06), p = 0.049]. This study demonstrated a weakly positive correlation between umbilical cord arterial pH and prelabour log10 STV (r = 0.107, p = 0.035) and the regression analyses revealed that the contributing factors for umbilical cord arterial pH were smoking (p = 0.006) and prelabour log10 STV (p = 0.025). CONCLUSIONS In pregnant women admitted in latent phase of labour or for induction of labour at term, prelabour cCTG STV had a weakly positive association with umbilical cord arterial pH but was not predictive of emergency delivery due to pathological CTG during labour.
Collapse
Affiliation(s)
- Sakita Moungmaithong
- Department of Obstetrics and Gynaecology, Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Michelle Sung Nga Lam
- Department of Obstetrics and Gynaecology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Angel Hoi Wan Kwan
- Department of Obstetrics and Gynaecology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Sani Tsz Kei Wong
- Department of Obstetrics and Gynaecology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Ada Wing Ting Tse
- Department of Obstetrics and Gynaecology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Daljit Singh Sahota
- Department of Obstetrics and Gynaecology, The Chinese University of Hong Kong, Hong Kong SAR, China
- Shenzhen Research Institute, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Sin Ting Angela Tai
- Department of Obstetrics and Gynaecology, The Chinese University of Hong Kong, Hong Kong SAR, China
| | - Liona Chiu Yee Poon
- Department of Obstetrics and Gynaecology, The Chinese University of Hong Kong, Hong Kong SAR, China
- Shenzhen Research Institute, The Chinese University of Hong Kong, Hong Kong SAR, China
| |
Collapse
|
2
|
Baschat AA, Galan HL, Lee W, DeVore GR, Mari G, Hobbins J, Vintzileos A, Platt LD, Manning FA. The role of the fetal biophysical profile in the management of fetal growth restriction. Am J Obstet Gynecol 2022; 226:475-486. [PMID: 35369904 DOI: 10.1016/j.ajog.2022.01.020] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2021] [Revised: 01/17/2022] [Accepted: 01/21/2022] [Indexed: 11/01/2022]
Abstract
Growth-restricted fetuses are at risk of hypoxemia, acidemia, and stillbirth because of progressive placental dysfunction. Current fetal well-being, neonatal risks following delivery, and the anticipated rate of fetal deterioration are the major management considerations in fetal growth restriction. Surveillance has to quantify the fetal risks accurately to determine the delivery threshold and identify the testing frequency most likely to capture future deterioration and prevent stillbirth. From the second trimester onward, the biophysical profile score correlates over 90% with the current fetal pH, and a normal score predicts a pH >7.25 with a 100% positive predictive value; an abnormal score on the other hand predicts current fetal acidemia with similar certainty. Between 30% and 70% of growth-restricted fetuses with a nonreactive heart rate require biophysical profile scoring to verify fetal well-being, and an abnormal score in 8% to 27% identifies the need for delivery, which is not suspected by Doppler findings. Future fetal well-being is not predicted by the biophysical profile score, which emphasizes the importance of umbilical artery Doppler and amniotic fluid volume to determine surveillance frequency. Studies with integrated surveillance strategies that combine frequent heart rate monitoring with biophysical profile scoring and Doppler report better outcomes and stillbirth rates of between 0% and 4%, compared with those between 8% and 11% with empirically determined surveillance frequency. The variations in clinical behavior and management challenges across gestational age are better addressed when biophysical profile scoring is integrated into the surveillance of fetal growth restriction. This review aims to provide guidance on biophysical profile scoring in the in- and outpatient management of fetal growth restriction.
Collapse
|
3
|
Lam MSN, Chaemsaithong P, Kwan AHW, Wong STK, Tse AWT, Sahota DS, Leung TY, Poon LC. Prelabor short-term variability in fetal heart rate by computerized cardiotocogram and maternal fetal doppler indices for the prediction of labor outcomes. J Matern Fetal Neonatal Med 2020; 35:1318-1327. [PMID: 32283958 DOI: 10.1080/14767058.2020.1752657] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Objectives: To investigate (i) the association between pre-labor maternal-fetal Dopplers and fetal heart rate short-term variability (FHR STV) with arterial cord blood pH and (ii) the potential value of pre-labor maternal-fetal Dopplers, FHR STV and Dawes-Redman criteria in predicting composite neonatal morbidity at term in a cohort of unselected women.Method: A prospective study in 218 women with term singleton pregnancy in latent phase of labor or due to undergo induction of labor. Data on maternal characteristics, maternal-fetal Dopplers indices and computerized cardiotocography (CTG) findings of FHR STV and Dawes-Redman criteria were collected. Pearson correlation analysis was used to determine the relationship between maternal-fetal Dopplers and FHR STV and arterial cord blood pH. Logistic regression analysis was used to determine which factors amongst maternal characteristics, labor onset, indication of labor induction, estimated fetal weight (EFW), maternal-fetal Dopplers, FHR STV and Dawes-Redman criteria were significant predictors of composite neonatal morbidity and arterial cord blood pH less than 7.2.Result: Of the 218 cases, 12 (5.5%) women were delivered by emergency operative delivery for pathological CTG, and 42 babies (19.3%) had composite neonatal morbidities. Arterial cord blood pH was not associated with maternal-fetal Doppler indices and FHR STV, but rather it was associated with maternal age and body mass index. The composite neonatal morbidity and arterial cord blood pH less than 7.2 were not significantly associated with maternal characteristics, labor onset, indication of labor induction, pre-labor assessment of EFW, maternal-fetal Doppler indices, FHR STV and Dawes-Redman criteria by computerized CTG.Conclusion: In unselected women in latent phase of labor or undergoing induction of labor at term, admission maternal-fetal Doppler indices, FHR STV and Dawes-Redman criteria are not predictive of composite neonatal morbidity.
Collapse
Affiliation(s)
- Michelle S N Lam
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - Piya Chaemsaithong
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - Angel H W Kwan
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - Sani T K Wong
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - Ada W T Tse
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - Daljit S Sahota
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - Tak Yeung Leung
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| | - Liona C Poon
- Department of Obstetrics and Gynaecology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong SAR
| |
Collapse
|
4
|
Directive clinique N° 393 - Le diabète pendant la grossesse. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2019; 41:1826-1839.e1. [DOI: 10.1016/j.jogc.2019.03.022] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
5
|
Berger H, Gagnon R, Sermer M. Guideline No. 393-Diabetes in Pregnancy. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2019; 41:1814-1825.e1. [PMID: 31785800 DOI: 10.1016/j.jogc.2019.03.008] [Citation(s) in RCA: 43] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
OBJECTIVES This guideline reviews the evidence relating to the diagnosis and obstetrical management of diabetes in pregnancy. OUTCOMES The outcomes evaluated were short and long-term maternal outcomes including pre-eclampsia, Caesarean section, future diabetes and other cardiovascular complications; and fetal outcomes including congenital anomalies, stillbirth, macrosomia, birth trauma, hypoglycemia and long-term effects. EVIDENCE Published literature was retrieved through searches of PubMed and The Cochrane Library using appropriate controlled vocabulary (MeSH terms "diabetes" and "pregnancy"). Where appropriate, results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. There were no date limits but results were limited to English or French language materials. VALUES The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care. SUMMARY STATEMENTS RECOMMENDATIONS.
Collapse
|
6
|
No. 197a-Fetal Health Surveillance: Antepartum Consensus Guideline. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2019; 40:e251-e271. [PMID: 29680082 DOI: 10.1016/j.jogc.2018.02.007] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE This guideline provides new recommendations pertaining to the application and documentation of fetal surveillance in the antepartum period that will decrease the incidence of birth asphyxia while maintaining the lowest possible rate of obstetrical intervention. Pregnancies with and without risk factors for adverse perinatal outcomes are considered. This guideline presents an alternative classification system for antenatal fetal non-stress testing to what has been used previously. This guideline is intended for use by all health professionals who provide antepartum care in Canada. OPTIONS Consideration has been given to all methods of fetal surveillance currently available in Canada. OUTCOMES Short- and long-term outcomes that may indicate the presence of birth asphyxia were considered. The associated rates of operative and other labour interventions were also considered. EVIDENCE A comprehensive review of randomized controlled trials published between January 1996 and March 2007 was undertaken, and MEDLINE and the Cochrane Database were used to search the literature for all new studies on fetal surveillance antepartum. The level of evidence has been determined using the criteria and classifications of the Canadian Task Force on Preventive Health Care (Table 1). SPONSOR This consensus guideline was jointly developed by the Society of Obstetricians and Gynaecologists of Canada and the British Columbia Perinatal Health Program (formerly the British Columbia Reproductive Care Program or BCRCP) and was partly supported by an unrestricted educational grant from the British Columbia Perinatal Health Program. RECOMMENDATION 1: FETAL MOVEMENT COUNTING: RECOMMENDATION 2: NON-STRESS TEST: RECOMMENDATION 3: CONTRACTION STRESS TEST: RECOMMENDATION 4: BIOPHYSICAL PROFILE: RECOMMENDATION 5: UTERINE ARTERY DOPPLER: RECOMMENDATION 6: UMBILICAL ARTERY DOPPLER.
Collapse
|
7
|
Liston R, Sawchuck D, Young D. N° 197a-Surveillance du bien-être fœtal : Directive consensus d'antepartum. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2019; 40:e272-e297. [PMID: 29680083 DOI: 10.1016/j.jogc.2018.02.008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
8
|
Berger H, Gagnon R, Sermer M. Archivée: Le diabète pendant la grossesse. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2016; 38:680-694.e2. [DOI: 10.1016/j.jogc.2016.05.001] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
9
|
Berger H, Gagnon R, Sermer M, Basso M, Bos H, Brown RN, Bujold E, Cooper SL, Gagnon R, Gouin K, McLeod NL, Menticoglou SM, Mundle WR, Roggensack A, Sanderson FL, Walsh JD. Diabetes in Pregnancy. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2016; 38:667-679.e1. [PMID: 27591352 DOI: 10.1016/j.jogc.2016.04.002] [Citation(s) in RCA: 51] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
OBJECTIVE This guideline reviews the evidence relating to the diagnosis and obstetrical management of diabetes in pregnancy. OUTCOMES The outcomes evaluated were short- and long-term maternal outcomes, including preeclampsia, Caesarean section, future diabetes, and other cardiovascular complications, and fetal outcomes, including congenital anomalies, stillbirth, macrosomia, birth trauma, hypoglycemia, and long-term effects. EVIDENCE Published literature was retrieved through searches of PubMed and the Cochrane Library using appropriate controlled vocabulary (MeSH terms "diabetes" and "pregnancy"). Where appropriate, results were restricted to systematic reviews, randomized control trials/controlled clinical trials, and observational studies. There were no date limits, but results were limited to English or French language materials. VALUES The quality of evidence was rated using the criteria described in the Report of the Canadian Task Force on Preventive Health Care (Table 1). SUMMARY STATEMENTS Recommendations It is recognized that the use of different diagnostic thresholds for the "preferred" and "alternative" strategies could cause confusion in certain settings. Despite this, the committee has identified the importance of remaining aligned with the current Canadian Diabetes Association 2013 guidelines as being a priority. It is thus recommended that each care centre strategically align with 1 of the 2 strategies and implement protocols to ensure consistent and uniform reporting of test results.
Collapse
|
10
|
Booker W, Fox NS, Gupta S, Carroll R, Saltzman DH, Klauser CK, Rebarber A. Antenatal Surveillance in Twin Pregnancies Using the Biophysical Profile. JOURNAL OF ULTRASOUND IN MEDICINE : OFFICIAL JOURNAL OF THE AMERICAN INSTITUTE OF ULTRASOUND IN MEDICINE 2015; 34:2071-2075. [PMID: 26453124 DOI: 10.7863/ultra.14.12063] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2014] [Accepted: 03/01/2015] [Indexed: 06/05/2023]
Abstract
Objectives-The nonstress test is currently the most widely used modality for antenatal surveillance in twin pregnancies, with a quoted false-positive rate of 11%-12%. Our objective was to report our experience with the sonographic portion of the biophysical profile in twin pregnancies as the primary screening modality.Methods-Women with twin pregnancies delivered by a single maternal-fetal medicine practice from 2005 to 2013 were included. We excluded monoamniotic twins. Twin pregnancies began weekly sonography for the biophysical profile starting at 32 to 33 weeks, or earlier if indicated. The nonstress test was performed if the sonographic biophysical profile score was less than 8 of 8. We reviewed biophysical profile scores and outcomes for all patients who delivered at 33 weeks or later to assess the false-positive rate for the biophysical profile, as well as the incidence of intrauterine fetal death (IUFD) after initiation of antenatal surveillance.Results-A total of 539 twin pregnancies were included. The incidence of IUFD per patient was 2 per 539 (0.4%; 95% confidence interval [CI], 0.1%-1.3%), and the incidence of IUFD per fetus was 2 per 1078 (0.19%; 95% CI, 0.05%-0.7%). The overall positive screen rate was 24 per 539 (4.45%; 95% CI, 3.0%-6.5%). The false-positive screen rate, defined as an abnormal biophysical profile that did not diagnose an IUFD or lead to delivery, was 10 per 539 (1.9%; 95% CI, 1.0%-3.4%).Conclusions-In twin pregnancies the use of the sonographic biophysical profile for routine antenatal surveillance has a low false-positive rate, with a very low incidence of IUFD. The sonographic biophysical profile should be considered as a primary mode for antenatal surveillance in twin pregnancies, with a reflex nonstress test for an abnormal score.
Collapse
Affiliation(s)
- Whitney Booker
- Department of Obstetrics, Gynecology, and Reproductive Science, Icahn School of Medicine at Mount Sinai, New York, New York USA (W.B., N.S.F., S.G., R.C., D.H.S., C.K.K., A.R.); Maternal-Fetal Medicine Associates, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.); and Carnegie Imaging for Women, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.)
| | - Nathan S Fox
- Department of Obstetrics, Gynecology, and Reproductive Science, Icahn School of Medicine at Mount Sinai, New York, New York USA (W.B., N.S.F., S.G., R.C., D.H.S., C.K.K., A.R.); Maternal-Fetal Medicine Associates, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.); and Carnegie Imaging for Women, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.)
| | - Simi Gupta
- Department of Obstetrics, Gynecology, and Reproductive Science, Icahn School of Medicine at Mount Sinai, New York, New York USA (W.B., N.S.F., S.G., R.C., D.H.S., C.K.K., A.R.); Maternal-Fetal Medicine Associates, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.); and Carnegie Imaging for Women, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.)
| | - Rachel Carroll
- Department of Obstetrics, Gynecology, and Reproductive Science, Icahn School of Medicine at Mount Sinai, New York, New York USA (W.B., N.S.F., S.G., R.C., D.H.S., C.K.K., A.R.); Maternal-Fetal Medicine Associates, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.); and Carnegie Imaging for Women, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.)
| | - Daniel H Saltzman
- Department of Obstetrics, Gynecology, and Reproductive Science, Icahn School of Medicine at Mount Sinai, New York, New York USA (W.B., N.S.F., S.G., R.C., D.H.S., C.K.K., A.R.); Maternal-Fetal Medicine Associates, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.); and Carnegie Imaging for Women, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.)
| | - Chad K Klauser
- Department of Obstetrics, Gynecology, and Reproductive Science, Icahn School of Medicine at Mount Sinai, New York, New York USA (W.B., N.S.F., S.G., R.C., D.H.S., C.K.K., A.R.); Maternal-Fetal Medicine Associates, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.); and Carnegie Imaging for Women, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.)
| | - Andrei Rebarber
- Department of Obstetrics, Gynecology, and Reproductive Science, Icahn School of Medicine at Mount Sinai, New York, New York USA (W.B., N.S.F., S.G., R.C., D.H.S., C.K.K., A.R.); Maternal-Fetal Medicine Associates, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.); and Carnegie Imaging for Women, PLLC, New York, New York USA (N.S.F., S.G., D.H.S., C.K.K., A.R.).
| |
Collapse
|
11
|
Seikku L, Rahkonen L, Tikkanen M, Hämäläinen E, Rahkonen P, Andersson S, Teramo K, Paavonen J, Stefanovic V. Amniotic fluid erythropoietin and neonatal outcome in pregnancies complicated by intrauterine growth restriction before 34 gestational weeks. Acta Obstet Gynecol Scand 2015; 94:288-94. [PMID: 25484184 DOI: 10.1111/aogs.12553] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2014] [Accepted: 11/24/2014] [Indexed: 12/30/2022]
Abstract
OBJECTIVE High amniotic fluid erythropoietin concentration reflects chronic fetal hypoxia. Our aim was to study amniotic fluid erythropoietin concentration in relation to neonatal outcome in pregnancies complicated by intrauterine growth restriction. DESIGN Retrospective case series. SETTING Helsinki University Hospital, Finland. SAMPLE A total of 66 singleton pregnancies complicated by intrauterine growth restriction. METHODS Amniocentesis or amniotic fluid sampling at cesarean section was performed between 24 and 34 gestational weeks. Values of amniotic fluid erythropoietin were quantitated with immunochemiluminometric assay. Normal amniotic fluid erythropoietin was defined as <3 IU/L, intermediate as 3-27 IU/L, and abnormal as >27 IU/L. MAIN OUTCOME MEASURES Adverse neonatal outcome. RESULTS Abnormal biophysical profile and reversed end-diastolic flow in umbilical artery were associated with abnormal amniotic fluid erythropoietin (p < 0.001 and p = 0.042, respectively). Abnormal amniotic fluid erythropoietin was not associated with absent end-diastolic flow in umbilical artery or with oligohydramnios (p = 0.404 and p = 0.080, respectively). Decreased umbilical artery pH and base excess values were associated with abnormal amniotic fluid erythropoietin (p = 0.027 and p = 0.007, respectively). Composite adverse neonatal outcome defined as intraventricular hemorrhage, periventricular leukomalacia, cerebral infarction and/or necrotizing enterocolitis was associated with abnormal amniotic fluid erythropoietin (p < 0.001). CONCLUSIONS High amniotic fluid erythropoietin concentrations are associated with decreased umbilical artery pH and base excess and with adverse neonatal outcome in pregnancies complicated by intrauterine growth restriction before 34 gestational weeks. In selected pregnancies complicated by intrauterine growth restriction, determining amniotic fluid erythropoietin could be a useful additional tool in fetal surveillance and possibly in optimizing timing of delivery.
Collapse
Affiliation(s)
- Laura Seikku
- Department of Obstetrics and Gynecology, Helsinki University Central Hospital, Helsinki, Finland
| | | | | | | | | | | | | | | | | |
Collapse
|
12
|
Figueras F, Gratacós E. Update on the Diagnosis and Classification of Fetal Growth Restriction and Proposal of a Stage-Based Management Protocol. Fetal Diagn Ther 2014; 36:86-98. [DOI: 10.1159/000357592] [Citation(s) in RCA: 394] [Impact Index Per Article: 39.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2013] [Accepted: 11/19/2013] [Indexed: 11/19/2022]
|
13
|
Baschat AA. Neurodevelopment after fetal growth restriction. Fetal Diagn Ther 2013; 36:136-42. [PMID: 23886893 DOI: 10.1159/000353631] [Citation(s) in RCA: 99] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2013] [Accepted: 05/29/2013] [Indexed: 11/19/2022]
Abstract
Fetal growth restriction (FGR) can emerge as a complication of placental dysfunction and increases the risk for neurodevelopmental delay. Marked elevations of umbilical artery (UA) Doppler resistance that set the stage for cardiovascular and biophysical deterioration with subsequent preterm birth characterize early-onset FGR. Minimal, or absent UA Doppler abnormalities and isolated cerebral Doppler changes with subtle deterioration and a high risk for unanticipated term stillbirth are characteristic for late-onset FGR. Nutritional deficiency manifested in lagging head growth is the most powerful predictor of developmental delay in all forms of FGR. Extremes of blood flow resistance and cardiovascular deterioration, prematurity and intracranial hemorrhage increase the risks for psychomotor delay and cerebral palsy. In late-onset FGR, regional cerebral vascular redistribution correlates with abnormal behavioral domains. Irrespective of the phenotype of FGR, prenatal tests that provide precise and independent stratification of risks for adverse neurodevelopment have yet to be determined.
Collapse
Affiliation(s)
- Ahmet A Baschat
- Center for Advanced Fetal Care, Department of Obstetrics and Gynecology and Reproductive Sciences, University of Maryland School of Medicine, Baltimore, Md., USA
| |
Collapse
|
14
|
Paulson JF, Chauhan SP, Hill JB, Abuhamad AZ. Severe small size for gestational age and cognitive function: catch-up phenomenon possible. Am J Obstet Gynecol 2012; 207:119.e1-5. [PMID: 22728029 DOI: 10.1016/j.ajog.2012.05.026] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2012] [Revised: 05/11/2012] [Accepted: 05/30/2012] [Indexed: 11/25/2022]
Abstract
OBJECTIVE We sought to compare cognitive functioning in children born with birthweight <3% vs ≥3% for gestational age (GA) between 9 months and kindergarten. STUDY DESIGN Nonanomalous singletons from the Early Childhood Longitudinal Study-Birth Cohort were included. Associations between weight for GA and cognitive functioning were examined using a series of confounder-adjusted general linear models. RESULTS Of 3633 cohorts, 585 (16%) were <3% for GA. At 9 months, cognitive performance of newborns <3% was about 12 percentile points lower than their normal counterparts (P < .001). By 2 years, however, no significant cognitive differences between these groups were observed (P = .668). Academic performance at preschool age (around 3.5 years) was not different for reading (P = .245) or math (P = .880), nor different at kindergarten age. CONCLUSION Newborns <3% for GA exhibit catch-up cognitive functioning by 2 years, with relatively no decrements in academic functioning observed by kindergarten.
Collapse
|
15
|
Berkley E, Chauhan SP, Abuhamad A, Abuhamad A. Doppler assessment of the fetus with intrauterine growth restriction. Am J Obstet Gynecol 2012; 206:300-8. [PMID: 22464066 DOI: 10.1016/j.ajog.2012.01.022] [Citation(s) in RCA: 136] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2012] [Accepted: 01/12/2012] [Indexed: 10/28/2022]
Abstract
OBJECTIVE We sought to provide evidence-based guidelines for utilization of Doppler studies for fetuses with intrauterine growth restriction (IUGR). METHODS Relevant documents were identified using PubMed (US National Library of Medicine, 1983 through 2011) publications, written in English, which describe the peripartum outcomes of IUGR according to Doppler assessment of umbilical arterial, middle cerebral artery, and ductus venosus. Additionally, the Cochrane Library, organizational guidelines, and studies identified through review of the above were utilized to identify relevant articles. Consistent with US Preventive Task Force suggestions, references were evaluated for quality based on the highest level of evidence, and recommendations were graded. RESULTS AND RECOMMENDATIONS Summary of randomized and quasirandomized studies indicates that, among high-risk pregnancies with suspected IUGR, the use of umbilical arterial Doppler assessment significantly decreases the likelihood of labor induction, cesarean delivery, and perinatal deaths (1.2% vs 1.7%; relative risk, 0.71; 95% confidence interval, 0.52-0.98). Antepartum surveillance with Doppler of the umbilical artery should be started when the fetus is viable and IUGR is suspected. Although Doppler studies of the ductus venous, middle cerebral artery, and other vessels have some prognostic value for IUGR fetuses, currently there is a lack of randomized trials showing benefit. Thus, Doppler studies of vessels other than the umbilical artery, as part of assessment of fetal well-being in pregnancies complicated by IUGR, should be reserved for research protocols.
Collapse
|
16
|
Chauhan SP. Deliver for oligohydramnios at 340/7 to 366/7 weeks. Am J Obstet Gynecol 2011. [DOI: 10.1016/j.ajog.2011.02.082] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
17
|
Baschat AA. Neurodevelopment following fetal growth restriction and its relationship with antepartum parameters of placental dysfunction. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2011; 37:501-514. [PMID: 21520312 DOI: 10.1002/uog.9008] [Citation(s) in RCA: 170] [Impact Index Per Article: 13.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/30/2023]
Abstract
Placental dysfunction leading to fetal growth restriction (FGR) is an important risk factor for neurodevelopmental delay. Recent observations clarify that FGR evolves prenatally from a preclinical phase of abnormal nutrient and endocrine milieu to a clinical phase that differs in characteristics in preterm and term pregnancies. Relating childhood neurodevelopment to these prenatal characteristics offers potential advantages in identifying mechanisms and timing of critical insults. Based on available studies, lagging head circumference, overall degree of FGR, gestational age, and umbilical artery (UA), aortic and cerebral Doppler parameters are the independent prenatal determinants of infant and childhood neurodevelopment. While head circumference is important independent of gestational age, overall growth delay has the greatest impact in early onset FGR. Gestational age has an overriding negative effect on neurodevelopment until 32-34 weeks' gestation. Accordingly, the importance of Doppler status is demonstrated from 27 weeks onward and is greatest when there is reversed end-diastolic velocity in the UA or aorta. While these findings predominate in early-onset FGR, cerebral vascular impedance changes become important in late onset FGR. Abnormal motor and neurological delay occur in preterm FGR, while cognitive effects and abnormalities that can be related to specific brain areas increase in frequency as gestation advances, suggesting different pathophysiology and evolving vulnerability of the fetal brain. Observational and management studies do not suggest that fetal deterioration has an independent impact on neurodevelopment in early-onset FGR. In late-onset FGR further research needs to establish benefits of perinatal intervention, as the pattern of vulnerability and effects of fetal deterioration appear to differ in the third trimester.
Collapse
Affiliation(s)
- A A Baschat
- Department of Obstetrics, Gynecology & Reproductive Sciences, University of Maryland School of Medicine, Baltimore, MD, USA.
| |
Collapse
|
18
|
Intrauterine growth restriction: new concepts in antenatal surveillance, diagnosis, and management. Am J Obstet Gynecol 2011; 204:288-300. [PMID: 21215383 DOI: 10.1016/j.ajog.2010.08.055] [Citation(s) in RCA: 278] [Impact Index Per Article: 21.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2010] [Revised: 08/10/2010] [Accepted: 08/27/2010] [Indexed: 12/26/2022]
Abstract
Intrauterine growth restriction (IUGR) remains one of the main challenges in maternity care. Improvements have to start from a better definition of IUGR, applying the concept of the fetal growth potential. Customized standards for fetal growth and birthweight improve the detection of IUGR by better distinction between physiological and pathological smallness and have led to internationally applicable norms. Such developments have resulted in new insights in the assessment of risk and surveillance during pregnancy. Serial fundal height measurement plotted on customized charts is a useful screening tool, whereas fetal biometry and Doppler flow are the mainstay for investigation and diagnosis of IUGR. Appropriate protocols based on available evidence as well as individualized clinical assessment are essential to ensure good management and timely delivery.
Collapse
|
19
|
Oyelese Y, Vintzileos AM. The uses and limitations of the fetal biophysical profile. Clin Perinatol 2011; 38:47-64, v-vi. [PMID: 21353089 DOI: 10.1016/j.clp.2010.12.008] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
In the second half of the twentieth century, true antepartum fetal assessment became possible, mainly due to the advent of real-time ultrasound. Initially, the most widely used form of antepartum fetal assessment was electronic fetal heart rate monitoring, through the nonstress test or the oxytocin-induced contraction stress test. It was soon realized, however, that these forms of monitoring had significant limitations. The biophysical profile allows a more thorough evaluation of fetal well-being and has the potential to significantly reduce the false-positive rate of the nonstress test/contraction stress test.
Collapse
Affiliation(s)
- Yinka Oyelese
- The Perinatal Institute, Department of Obstetrics & Gynecology, Jersey Shore University Medical Center, Suite 203, 1944 State Route 33, Neptune, NJ 07753, USA.
| | | |
Collapse
|
20
|
Abstract
PURPOSE OF REVIEW Recognition of the fetus at risk for death or damage in utero, quantifying the risk, balancing fetal risk against the risk of neonatal complications from immaturity and determining optimal time and mode of intervention, is a cornerstone of modern perinatal medicine. Antepartum fetal testing is essential in making these crucial decisions. The art and science of fetal assessment is fluid. In this treatise, the evolution of testing is reviewed, test accuracy results examined and suggestions for future applications are considered. RECENT FINDINGS Composite testing of a range of fetal biophysical variables is an excellent predictor of fetal acidemia and risk of death or damage. Confusion regarding the optimal means of measuring one of these variables, amniotic fluid volume, has been addressed in the literature and contemporary studies from several independent sources indicate that the amniotic fluid index method should be abandoned in favor of the maximal vertical pocket method. It is becoming increasingly more evident that a spectrum of fetal testing modalities based on interrogation of different aspects of fetal adaptive responses to adversity is preferable in fetal testing. Further it is evident that in some fetal diseases, such as intrauterine growth restriction, fetal condition may change acutely and accordingly best outcome is achieved by much more frequent testing. The question of whether intervention for fetal compromise can prevent subsequent neurological sequelae remains open. SUMMARY There has been remarkable advancement in identifying the fetus at risk. The concept of multispectral combined fetal testing including acute biophysical variables, amniotic fluid volume and arterial and venous Doppler flow velocity waveforms is established.
Collapse
Affiliation(s)
- Frank A Manning
- Department of Obstetrics and Gynecology, Division of Maternal-Fetal Medicine, New York Medical College, Valhalla, New York, USA.
| |
Collapse
|
21
|
Petrović O, Finderle A, Prodan M, Škunca E, Prpić I, Zaputović S. Combination of vibroacoustic stimulation and acute variables of mFBP as a simple assessment method of low-risk fetuses. J Matern Fetal Neonatal Med 2009; 22:152-6. [DOI: 10.1080/14767050802616960] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
22
|
Hayashi R, Nakai K, Fukushima A, Itoh M, Sugiyama T. Development and significance of a fetal electrocardiogram recorded by signal-averaged high-amplification electrocardiography. Int Heart J 2009; 50:161-71. [PMID: 19367027 DOI: 10.1536/ihj.50.161] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Although ultrasonic diagnostic imaging and fetal heart monitors have undergone great technological improvements, the development and use of fetal electrocardiograms to evaluate fetal arrhythmias and autonomic nervous activity have not been fully established. We verified the clinical significance of the novel signal-averaged vector-projected high amplification ECG (SAVP-ECG) method in fetuses from 48 gravidas at 32-41 weeks of gestation and in 34 neonates. SAVP-ECGs from fetuses and newborns were recorded using a modified XYZ-leads system. Once noise and maternal QRS waves were removed, the P, QRS, and T wave intervals were measured from the signal-averaged fetal ECGs. We also compared fetal and neonatal heart rates (HRs), coefficients of variation of heart rate variability (CV) as a parasympathetic nervous activity, and the ratio of low to high frequency (LF/HF ratio) as a sympathetic nervous activity. The rate of detection of a fetal ECG by SAVP-ECG was 72.9%, and the fetal and neonatal QRS and QTc intervals were not significantly different. The neonatal CVs and LF/HF ratios were significantly increased compared with those in the fetus. In conclusion, we have developed a fetal ECG recording method using the SAVP-ECG system, which we used to evaluate autonomic nervous system development.
Collapse
Affiliation(s)
- Risa Hayashi
- Department of Obstetrics and Gynecology, Iwate Medical University, Iwate, Japan
| | | | | | | | | |
Collapse
|
23
|
Baschat AA, Viscardi RM, Hussey-Gardner B, Hashmi N, Harman C. Infant neurodevelopment following fetal growth restriction: relationship with antepartum surveillance parameters. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2009; 33:44-50. [PMID: 19072744 DOI: 10.1002/uog.6286] [Citation(s) in RCA: 73] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
OBJECTIVES To evaluate the relationship between fetal Doppler parameters, biophysical profile score (BPP) and neurodevelopmental delay at 2 years of corrected age in infants who had been growth-restricted in utero. METHODS This was a prospective observational study including 113 pregnancies complicated by intrauterine growth restriction (IUGR) (abdominal circumference<5th percentile and elevated umbilical artery (UA) pulsatility index). The relationships of UA, middle cerebral artery and ductus venosus (DV) Doppler features, BPP, birth acidemia (artery pH<7.0+/or base deficit>12), gestational age at delivery, birth weight and neonatal morbidity (i.e. bronchopulmonary dysplasia, >Grade 2 intraventricular hemorrhage, or necrotizing enterocolitis) with a 2-year neurodevelopmental delay were evaluated. Best Beginnings Developmental Screen, Bayley Scale of Infant Development II (BSID) and Clinical Adaptive/Clinical Linguistic Auditory Milestone Stage were used. BSID<70, cerebral palsy, abnormal tone, hearing loss and/or blindness defined neurodevelopmental delay. RESULTS Seventy-two of the 113 pregnancies completed assessment; there were 10 stillbirths, 19 neonatal deaths, three infant deaths and nine pregnancies with no follow-up. Twenty fetuses (27.8%) had UA reversed end-diastolic velocity (REDV), 34 (47.2%) abnormal DV Doppler features and 31 (43.1%) an abnormal BPP. Median gestational age at delivery and birth weight were 30.4 weeks and 933 g, respectively. Twelve infants had acidemia and 28 neonatal morbidity. There were 38 (52.8%) infants with neurodevelopmental delay, including 37 (51.4%) with abnormal tone, 20 (27.8%) with speech delay, 23 (31.9%) with an abnormal neurological examination, eight (11.1%) with a hearing deficit and six (8.3%) with cerebral palsy. Gestational age at delivery was associated with cerebral palsy (r2=0.52, P<0.0001; 92% sensitivity and 83% specificity for delivery at <27 weeks). UA-REDV was associated with global delay (r2=0.31, P=0.006) and birth weight with neurodevelopmental delay (r2=0.54, P<0.0001; 82% sensitivity and 64% specificity for BW<922 g). CONCLUSIONS Although UA-REDV is an independent contributor to poor neurodevelopment in IUGR no such effect could be demonstrated for abnormal venous Doppler findings or BPP. Gestational age and birth weight remain the predominant factors for poor neurodevelopment in growth-restricted infants.
Collapse
Affiliation(s)
- A A Baschat
- Department of Obstetrics, Gynecology and Reproductive Sciences, University of Maryland, Baltimore, MD 21201-1703, USA.
| | | | | | | | | |
Collapse
|
24
|
References. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2007. [DOI: 10.1016/s1701-2163(16)32622-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
25
|
Johnson JM, Chauhan SP, Ennen CS, Niederhauser A, Magann EF. A comparison of 3 criteria of oligohydramnios in identifying peripartum complications: a secondary analysis. Am J Obstet Gynecol 2007; 197:207.e1-7; discussion 207.e7-8. [PMID: 17689653 DOI: 10.1016/j.ajog.2007.04.048] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2006] [Revised: 03/19/2007] [Accepted: 04/26/2007] [Indexed: 11/23/2022]
Abstract
OBJECTIVE The objective of the study was to ascertain the diagnostic accuracy of 3 criteria of oligohydramnios in identifying 4 peripartum complications. STUDY DESIGN The 3 definitions of oligohydramnios were amniotic fluid index (AFI) 5.0 cm or less and AFI <5% for gestational age (GA) using nomograms by Moore and Cayle or Magann et al. Likelihood ratio (LR) and guidelines by the Evidence-Based Medicine Working Group were used in the secondary analysis of previously published reports. AFI obtained during antepartum and intrapartum periods were analyzed separately. RESULTS The 95% confidence intervals for the prevalence of oligohydramnios using the 3 criteria are significantly different in the antepartum or intrapartum analysis. The LR was <6 for ante- and intrapartum AFI to identify cesarean delivery for nonreassuring fetal heart rate tracing, Apgar score 3 or less at 5 minutes, umbilical arterial pH <7.00, and newborns' weight 5% or less for GA. CONCLUSION The 3 criteria for determining the adequacy of amniotic fluid are not fungible, and they are not useful diagnostic tests for identifying peripartum complications because LR is <10.
Collapse
|
26
|
Abstract
The complexities of neurobehavioral assessment of the fetus, which can be neither directly viewed nor manipulated, cannot be understated. Impetus to develop methods for measuring fetal neurobehavioral development has been provided by the recognition that individual differences in neurobehavioral functioning do not originate with birth and acceptance of the key contribution of the antenatal period to postnatal life. Research has centered around four aspects of fetal functioning: heart rate, motor activity, behavioral state, and responsivity to stimulation. Longitudinal studies have revealed that the developmental trajectories of these characteristics parallel the developing nervous system, detected a transitional period between 28 and 32 weeks gestation, and established within-fetal stability during the second half of gestation. Despite the promise of fetal stimulation and habituation paradigms as measures of neural functioning, significant safety and ethical concerns exist. Construction of a unified fetal neurobehavioral scale is premature until a sufficient degree of normative data is available and the predictive validity of specific aspects of fetal neurobehavior to child developmental outcomes is better established.
Collapse
Affiliation(s)
- Janet A DiPietro
- Department of Population and Family Health Sciences, Bloomberg School of Public Health, Johns Hopkins University, Baltimore, MD 21205, USA.
| |
Collapse
|
27
|
Abstract
The growth-restricted fetus is a fetus who fails to reach his growth potential and is at risk for perinatal morbidity and mortality. When a fetus has an estimated weight below the 10th percentile, in the absence of congenital anomalies and in the presence of a normal amount of amniotic fluid, Doppler velocimetry gives the most important information to differentiate the truly growth-restricted fetus from the fetus that is constitutionally small but otherwise normal. One area of debate and research is whether Doppler velocimetry can help in timing the delivery of the growth-restricted fetus. Data appear to support the use of ductus venosus velocimetry in deciding when to deliver, but randomized data on this point are still lacking.
Collapse
Affiliation(s)
- Ursula F Harkness
- Division of Maternal Fetal Medicine, Department of Obstetrics and Gynecology, University of Cincinnati, 231 Albert Sabin Way, PO Box 670526, Cincinnati, OH 45267-0526, USA.
| | | |
Collapse
|
28
|
Odibo AO, Quinones JN, Lawrence-Cleary K, Stamilio DM, Macones GA. What antepartum fetal test should guide the timing of delivery of the preterm growth-restricted fetus? A decision-analysis. Am J Obstet Gynecol 2004; 191:1477-82. [PMID: 15507986 DOI: 10.1016/j.ajog.2004.05.066] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
OBJECTIVE The purpose of this study was to use a decision-analytic approach to explore the best strategy for the timing of the delivery of preterm intrauterine growth-restricted fetuses. STUDY DESIGN We constructed a decision-analysis model that compared 4 antenatal fetal testing strategies The fetal/neonatal states that were compared included live in utero pregnancy; fetal death; neonatal death; disabled neonate, and healthy neonate. Probability estimates for these states and sensitivity and specificity for Doppler velocimetry and biophysical profile were derived from literature review. Sensitivity analyses were performed on the baseline assumptions. RESULTS Under the baseline assumptions, biophysical profile was the best test to guide decisions on delivery. Sensitivity analyses revealed the model to be sensitive only to the specificity of a biophysical profile <82%. CONCLUSION Compared with the other options, biophysical profile was the best strategy to guide physicians on the timing of the delivery of the preterm growth-restricted fetus.
Collapse
Affiliation(s)
- Anthony O Odibo
- Division of Maternal-Fetal Medicine, Department of Gynecology and Obstetrics, University of Pennsylvania Medical Center, 3400 Spruce Street, 2000 Ravdin Courtyard, Philadelphia, PA 19104, USA.
| | | | | | | | | |
Collapse
|
29
|
Chauhan SP, Doherty DD, Magann EF, Cahanding F, Moreno F, Klausen JH. Amniotic fluid index vs single deepest pocket technique during modified biophysical profile: a randomized clinical trial. Am J Obstet Gynecol 2004; 191:661-7; discussion 667-8. [PMID: 15343260 DOI: 10.1016/j.ajog.2004.06.078] [Citation(s) in RCA: 46] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE The purpose of this study was to determine the superior technique, if either, of the amniotic fluid index (AFI) vs the single deepest pocket technique in predicting an adverse pregnancy outcome among high-risk patients undergoing antenatal testing. STUDY DESIGN Patients having modified biophysical profile (nonstress test plus sonographic estimation of amniotic fluid) were randomized to either have AFI or determination of the presence or absence of a 2 x 1-cm single deepest pocket. RESULTS Between January of 1997 and December of 2001, 1080 women were randomized with 530 women in the AFI arm, and 558 in the 2 x 1 pocket arm. The maternal demographics and prenatal complications were similar between groups. Significantly more patients were identified as having oligohydramnios using AFI (17%) compared with using 2 x 1 pocket (10%) ( P =.002). The overall rate of cesarean section for nonreassuring fetal heart rate (FHR) tracing was 3.8% (30 cases, with 16 cases in the AFI-monitored, and 14 cases in the 2 x 1 pocket-monitored groups, respectively, P =.608). Logistic regression analysis showed no difference between the groups with respect to the ability to identify patients who underwent cesarean section for nonreassuring FHR tracing during labor ( P =.999). The umbilical artery pH <7.1 ( P =.688) and admission to the newborn intensive care unit were also comparable between groups. CONCLUSION During antepartum fetal surveillance, use of single deepest pocket compared with amniotic fluid index is associated with a significantly lower rate of suspected oligohydramnios.
Collapse
Affiliation(s)
- Suneet P Chauhan
- Division of Maternal-Fetal Medicine, Regional Women's Health Care, Spartanburg Regional Medical Center, 853 N. Church Street, Spartanburg, SC 29303, USA.
| | | | | | | | | | | |
Collapse
|
30
|
|
31
|
Magann EF, Chauhan SP, Bofill JA, Martin JN. Comparability of the amniotic fluid index and single deepest pocket measurements in clinical practice. Aust N Z J Obstet Gynaecol 2003; 43:75-7. [PMID: 12755354 DOI: 10.1046/j.0004-8666.2003.00002.x] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
Two ultrasound techniques, the amniotic fluid index (AFI) and the single deepest pocket (SDP), are currently used to detect oligohydramnios, predict variable decelerations, risk of Caesarean delivery for fetal distress, Apgar scores, umbilical cord artery pH, perinatal mortality, and cerebral palsy. Both techniques poorly identify oligohydramnios. Both techniques identify pregnancies at risk for variable decelerations, low Apgar scores, and Caesarean delivery for fetal distress. Only the SDP is predictive of a compromised fetus-umbilical artery pH, as a stand-alone test, has been correlated with perinatal mortality, and as part of the biophysical profile has been linked to cerebral palsy. This brief communication reviews the comparability of these two techniques and which method, if either, is superior in the identification of oligohydramnios, the predictability of these techniques to identify an adverse pregnancy outcome, and the ability to predict cerebral palsy and perinatal mortality.
Collapse
Affiliation(s)
- Everett F Magann
- Department of Obstetrics and Gynaecology, The University of Western Australia, Perth, Australia.
| | | | | | | |
Collapse
|
32
|
Baschat AA. Integrated fetal testing in growth restriction: combining multivessel Doppler and biophysical parameters. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2003; 21:1-8. [PMID: 12528152 DOI: 10.1002/uog.21] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2023]
|
33
|
Affiliation(s)
- Frank A Manning
- Department of obstetrics, Gynecology and Women's Health, Albert Einstein College of Medicine, Bronx, New York, USA.
| |
Collapse
|
34
|
Lam G, Moise K. Antenatal Surveillance in Preeclampsia and Chronic Hypertension. Hypertens Pregnancy 2002. [DOI: 10.1201/b14088-11] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
|
35
|
Karaer C, Onderoglu L, Yigit N, Durukan T, Bahado-Singh RO. The effect of steroids on the biophysical profile and Doppler indices of umbilical and middle cerebral arteries in healthy preterm fetuses. Eur J Obstet Gynecol Reprod Biol 2001; 99:72-6. [PMID: 11604189 DOI: 10.1016/s0301-2115(01)00367-0] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
OBJECTIVE To examine the effect of antenatal steroids on the biophysical profile and the Doppler parameters of umbilical and middle cerebral arteries of healthy fetuses. STUDY DESIGN Thiry-five singleton pregnancies between the gestational ages of 28 and 34 weeks, who received two consecutive doses of betamethasone 24h apart to accelerate pulmonary maturation were prospectively studied. Fetal biophysical profile and Doppler assessment were performed at 0 (pre-steroid), 24, 48, 72, 96 and 120 h after the administration of first dose. We compared the percentage of the fetuses with biophysical parameters present for each of the five components of the biophysical profile and the Doppler indices, using Cochran's Q-test, Friedman's test and one way analysis of variance of repeated measures where appropriate. The statistical significance was defined as P<0.05. RESULTS The mean delivery time was 36.9(+/-1.8) weeks. There was a statistically significant difference in the frequency of the following findings in the pre- compared to post-steroid measurements: absence of body movements (48 h, P<0.05), non-reassuring fetal heart rate tracings (24, 48 and 72 h, P<0.05) and absence of breathing movements (24, 48 and 72 h, p<0.05). Initially none of the biophysical profile score was <or=6, whereas at 24, 48 and 72 h, 13.3, 76.7, 16.7% of them, respectively, were <or=6 (P<0.05). None of the Doppler indices was found to be affected by the steroid administration. CONCLUSION Maternal betamethasone administration can cause a significant but transient, reduction in biophysical profile scores, however the middle cerebral and umbilical artery Doppler indices were found to be unaffected suggesting the reliability of this modality for the evaluation of the fetuses previously exposed to the antenatal steroids.
Collapse
|
36
|
Abstract
Our knowledge about the cause of cerebral palsy continues to expand and prenatal events are thought to play an important role. This article reviews laboratory tests, imaging studies and pathologic findings that have been used to identify the timing of neurological injury. Limitations exist for all modalities, however, imaging studies, electroencephalograms and pathologic examination provide the most useful information. Improvements in our ability to time neurological injury will better direct our efforts to prevent cerebral palsy.
Collapse
Affiliation(s)
- L M Hollier
- Department of Obstetrics, Gynecology, and Reproductive Sciences, The University of Texas-Houston Medical School, 77026, USA.
| |
Collapse
|
37
|
Abstract
The incidence of cerebral palsy is 1 per 1,000, whereas the proportion caused by perinatal asphyxia is only 8% to 10%. The purpose of this article is to review the relationship between asphyxia and cerebral palsy. Only a minority of cases, those involving severe pathological fetal academia, are consistently associated with neonatal encephalopathy and an increased risk of cerebral palsy.
Collapse
Affiliation(s)
- E R Pschirrer
- Department of Obstetrics, Gynecology, and Reproductive Sciences, University of Texas-Houston Medical School, USA
| | | |
Collapse
|
38
|
Abstract
The objective of this study was to describe the fetal heart rate patterns and underlying pathophysiologic changes in the brain-damaged fetus. Fetuses with brain damage from hypoxic ischemic encephalopathy do not manifest uniform fetal heart rate patterns. However, these fetuses do show distinct fetal heart rate patterns that permit categorization based on their admission heart rate, subsequent changes in their baseline rate; and neonatal findings. Based on the observations of infants brain damaged in utero because of hypoxic ischemic encephalopathy, the intrapartum fetal management will depend on the admission fetal heart rate pattern, and the subsequent changes in the baseline rate.
Collapse
Affiliation(s)
- J P Phelan
- Department of Obstetrics and Gynecology, Pomona Valley Hospital Medical Center, and Childbirth Injury Prevention Foundation, Pasadena, CA, USA
| | | |
Collapse
|
39
|
Hershkovitz R, Kingdom JC, Geary M, Rodeck CH. Fetal cerebral blood flow redistribution in late gestation: identification of compromise in small fetuses with normal umbilical artery Doppler. ULTRASOUND IN OBSTETRICS & GYNECOLOGY : THE OFFICIAL JOURNAL OF THE INTERNATIONAL SOCIETY OF ULTRASOUND IN OBSTETRICS AND GYNECOLOGY 2000; 15:209-212. [PMID: 10846776 DOI: 10.1046/j.1469-0705.2000.00079.x] [Citation(s) in RCA: 136] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
Abstract
OBJECTIVE To evaluate the role of middle cerebral artery Doppler in small fetuses during the late third trimester. DESIGN Prospective observational study of structurally normal fetuses with an estimated fetal weight < 5th percentile for gestation. Perinatal outcome was determined using a structured datasheet sent to each referring obstetrician. SUBJECTS Structurally normal fetuses at 35 or more weeks of gestation referred during a 2-year period to the fetal growth clinic of a regional fetal medicine unit in North London. Fetuses with aneuploidy and/or major structural abnormalities were excluded. METHODS Umbilical artery and middle cerebral artery (MCA) Doppler waveforms were recorded and considered abnormal if above 95th or below 5th percentiles, respectively. Amniotic fluid was considered reduced if the maximum vertical cord-free pool was < 2 cm. The placenta was considered mature if the Grannum grade was II or III. The head circumference (HC)/abdominal circumference (AC) ratio was considered abnormal if > 95th percentile for gestation. Fetal growth, amniotic fluid, biophysical profile score and umbilical artery Doppler were used to advise the referring obstetrician about fetal well-being and he/she independently decided both the timing and mode of delivery. RESULTS Forty-seven fetuses fulfilled the entry criteria. Thirty-four (72%) demonstrated normal umbilical artery Doppler waveforms. Sixteen (34%) demonstrated middle cerebral artery redistribution, of which nine (56%) had normal umbilical artery Doppler waveforms. MCA blood flow redistribution was associated with an increased incidence of cesarean delivery and need for neonatal admission. Of all gray-scale parameters, an elevated HC/AC ratio has the strongest association with MCA blood flow redistribution (15/16 vs. 1/31; P < 0.01). CONCLUSIONS MCA Doppler may be a useful tool to assess the health of small fetuses in the late third trimester. Redistribution may occur in the presence of normal umbilical artery Doppler and should be suspected when the HC/AC ratio is elevated.
Collapse
Affiliation(s)
- R Hershkovitz
- Department of Obstetrics and Gynaecology, University College Hospital, London, UK
| | | | | | | |
Collapse
|
40
|
MacLennan A. A template for defining a causal relationship between acute intrapartum events and cerebral palsy: international consensus statement. International Cerebral Palsy Task Force. Aust N Z J Obstet Gynaecol 2000; 40:13-21. [PMID: 10870773 DOI: 10.1111/j.1479-828x.2000.tb03159.x] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- A MacLennan
- Department of Obstetrics and Gynaecology, University of Adelaide, Women's and Children's Hospital, North Adelaide, South Australia, Australia
| |
Collapse
|
41
|
Abstract
This article begins with an outline of the theoretic basis of the fetal biophysical profile, the method for the biophysical profile score (BPS), and the timing and frequency of testing. The article further discusses the clinical management based on test scores; modified methods of the BPS; and clinical application, predictive accuracy, and impact on outcome of BPS. The authors specifically examine the relationship between BPS and cerebral palsy. They conclude with a discussion of adult sequelae and fetal adaptation to asphyxia.
Collapse
Affiliation(s)
- F A Manning
- Department of Obstetrics and Gynecology, Albert Einstein College of Medicine, Bronx, New York, USA
| |
Collapse
|
42
|
Dayal AK, Manning FA, Berck DJ, Mussalli GM, Avila C, Harman CR, Menticoglou S. Fetal death after normal biophysical profile score: An eighteen-year experience. Am J Obstet Gynecol 1999; 181:1231-6. [PMID: 10561651 DOI: 10.1016/s0002-9378(99)70114-6] [Citation(s) in RCA: 45] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVE It was our goal to determine the false-negative rate of the biophysical profile, characterize an 18-year variation in the false-negative rate, examine the relationship between the last normal biophysical profile score and death, and compare the false-negative rate of 2 disparate populations. STUDY DESIGN Biophysical profile scores of 86,955 patients at 2 medical centers were collected and recorded prospectively. All perinatal deaths occurring within 1 week of a normal score were similarly recorded. The annual false-negative rate, the cumulative false-negative rate, and the ratio of false-negative results in cases of subsequent fetal death to the perinatal mortality rate were calculated. RESULTS There were 65 fetal deaths among 86,955 fetuses. Over an 18-year study period at one institution, the false-negative rate varied but not significantly. The cumulative false-negative rate was 0.708 per 1000 at one medical center studied and 2.289 per 1000 at the other center. The average interval between last normal score and fetal death was 3.62 days and did not vary significantly between the medical centers. CONCLUSIONS False-negative results in cases of subsequent fetal death reflect events that are subsequent to the last normal test result. Fetomaternal hemorrhage was the single most identifiable fetal cause of false-negative results in cases of subsequent fetal death. The ratio of the false-negative rate in cases of subsequent fetal death to the perinatal mortality rate should be used as a more objective approach to reporting this value, because the false-negative rate likely reflects the underlying perinatal mortality.
Collapse
Affiliation(s)
- A K Dayal
- Division of Maternal-Fetal Medicine, Department of Obstetrics and Gynecology, Columbia-Presbyterian Medical Center, New York, New York, USA
| | | | | | | | | | | | | |
Collapse
|
43
|
Abstract
Assessing fetal wellbeing has evolved from the ancient awareness of 'quickening' to a vast array of biophysical, imaging and biochemical methods. Because the results of these tests influence the urgency of fetal delivery and sometimes the choice of maternal anesthetic technique, it is important for anesthesiologists to understand the fundamentals of fetal monitoring and the changing face of new developments in this field. Noteworthy publications from the past year on this topic include new guidelines for the interpretation of fetal heart monitoring, advances in intrapartum fetal pulse oximetry, thresholds of acidosis associated with fetal injury, and efforts to decrease cerebral palsy through better antenatal biophysical testing.
Collapse
Affiliation(s)
- T G Cheek
- Department of Anesthesia, Hospital of the University of Pennsylvania, 3400 Spruce Street, Philadelphia, PA 19104, USA
| | | |
Collapse
|