1
|
Hussain NM, O'Halloran M, McDermott B, Elahi MA. Fetal monitoring technologies for the detection of intrapartum hypoxia - challenges and opportunities. Biomed Phys Eng Express 2024; 10:022002. [PMID: 38118183 DOI: 10.1088/2057-1976/ad17a6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2023] [Accepted: 12/20/2023] [Indexed: 12/22/2023]
Abstract
Intrapartum fetal hypoxia is related to long-term morbidity and mortality of the fetus and the mother. Fetal surveillance is extremely important to minimize the adverse outcomes arising from fetal hypoxia during labour. Several methods have been used in current clinical practice to monitor fetal well-being. For instance, biophysical technologies including cardiotocography, ST-analysis adjunct to cardiotocography, and Doppler ultrasound are used for intrapartum fetal monitoring. However, these technologies result in a high false-positive rate and increased obstetric interventions during labour. Alternatively, biochemical-based technologies including fetal scalp blood sampling and fetal pulse oximetry are used to identify metabolic acidosis and oxygen deprivation resulting from fetal hypoxia. These technologies neither improve clinical outcomes nor reduce unnecessary interventions during labour. Also, there is a need to link the physiological changes during fetal hypoxia to fetal monitoring technologies. The objective of this article is to assess the clinical background of fetal hypoxia and to review existing monitoring technologies for the detection and monitoring of fetal hypoxia. A comprehensive review has been made to predict fetal hypoxia using computational and machine-learning algorithms. The detection of more specific biomarkers or new sensing technologies is also reviewed which may help in the enhancement of the reliability of continuous fetal monitoring and may result in the accurate detection of intrapartum fetal hypoxia.
Collapse
Affiliation(s)
- Nadia Muhammad Hussain
- Discipline of Electrical & Electronic Engineering, University of Galway, Ireland
- Translational Medical Device Lab, Lambe Institute for Translational Research, University Hospital Galway, Ireland
| | - Martin O'Halloran
- Discipline of Electrical & Electronic Engineering, University of Galway, Ireland
- Translational Medical Device Lab, Lambe Institute for Translational Research, University Hospital Galway, Ireland
| | - Barry McDermott
- Translational Medical Device Lab, Lambe Institute for Translational Research, University Hospital Galway, Ireland
- College of Medicine, Nursing & Health Sciences, University of Galway, Ireland
| | - Muhammad Adnan Elahi
- Discipline of Electrical & Electronic Engineering, University of Galway, Ireland
- Translational Medical Device Lab, Lambe Institute for Translational Research, University Hospital Galway, Ireland
| |
Collapse
|
2
|
Yilmaz A, Cebi MN, Yilmaz G, Karacaoglu G, Aydin SN, Perk Y, Vural M. Long-term neurodevelopmental effects of exclusively high cord lactate levels in term newborn. J Matern Fetal Neonatal Med 2023; 36:2284115. [PMID: 37989542 DOI: 10.1080/14767058.2023.2284115] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2022] [Accepted: 11/12/2023] [Indexed: 11/23/2023]
Abstract
INTRODUCTION Cord arterial blood gas analysis (ABGA) results are used as diagnostic criteria for hypoxic-ischemic encephalopathy in newborns with suspected perinatal asphyxia. This study evaluated the effect of cord ABGA lactate level on the long-term neurodevelopment of newborns without any clinical signs of perinatal asphyxia. METHODS This clinical observation study was designed among term babies born between 2018 and 2019 in our unit. Cases with a 5-min Apgar score <7 and signs of fetal distress in their antenatal follow-up were excluded. The cases (n = 1438) were divided into two groups those with high cord lactate levels (above 5 mmol/L, n = 92) and those with low lactate levels (below 2 mmol/L, n = 255). An Ages and Stages Questionnaire, Third Edition (ASQ-3) developmental screening questionnaire was sent to all parents. Patients with a chronological age between 24 and 42 months and for whom the parents fulfilled the questionnaire (low lactate group, n = 29, and high lactate group, n = 45) were evaluated. RESULTS No difference was observed between the two groups in terms of demographic characteristics such as age (p = .1669), male gender (p = .906), mother's working situation (p = .948), mother's education level (p = .828), father's education level (p = .507), and family's total income (p = .642). Mean ACQ-3 developmental screening test scores were significantly lower in the high lactate group compared to the low lactate group concerning; fine motor (40 vs. 60, p = .001), problem-solving (50 vs. 60, p = .002), and personal social development (45 vs. 60, p = .003). No difference was observed in terms of communication and gross motor total scores. DISCUSSION In general practice, routine cord ABGA is not generally recommended for patients with normal Apgar scores and no suspected hypoxia. However, in this study, we observed that cases with a normal 5-min Apgar score, no suspected perinatal asphyxia, and a cord lactate value of ≥5 fell behind their peers when evaluated with the ACQ-3 developmental screening questionnaire.
Collapse
Affiliation(s)
- Aslan Yilmaz
- Department of Neonatology, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Fatih, Turkey
| | - Memnune Nur Cebi
- Department of Pediatrics, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Fatih, Turkey
| | - Gizem Yilmaz
- Department of Pediatrics, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Fatih, Turkey
| | - Gursel Karacaoglu
- Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Fatih, Turkey
| | - Sümeyye Nur Aydin
- Department of Public Health, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Fatih, Turkey
| | - Yildiz Perk
- Department of Neonatology, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Fatih, Turkey
| | - Mehmet Vural
- Department of Neonatology, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Fatih, Turkey
| |
Collapse
|
3
|
Olaetxea I, Lafuente H, Lopez E, Izeta A, Jaunarena I, Seifert A. Photonic Technology for In Vivo Monitoring of Hypoxia-Ischemia. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2022; 10:e2204834. [PMID: 36377426 PMCID: PMC9811478 DOI: 10.1002/advs.202204834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/22/2022] [Revised: 10/05/2022] [Indexed: 06/16/2023]
Abstract
Surveillance of physiological parameters of newborns during delivery triggers medical decision-making, can rescue life and health, and helps avoid unnecessary cesareans. Here, the development of a photonic technology for monitoring perinatal asphyxia is presented and validated in vivo in a preclinical stage. Contrary to state of the art, the technology provides continuous data in real-time in a non-invasive manner. Moreover, the technology does not rely on a single parameter as pH or lactate, instead monitors changes of the entirety of physiological parameters accessible by Raman spectroscopy. By a fiber-coupled Raman probe that is in controlled contact with the skin of the subject, near-infrared Raman spectra are measured and analyzed by machine learning algorithms to develop classification models. As a performance benchmarking, various hybrid and non-hybrid classifiers are tested. In an asphyxia model in newborn pigs, more than 1000 Raman spectra are acquired at three different clinical phases-basal condition, hypoxia-ischemia, and post-hypoxia-ischemia stage. In this preclinical proof-of-concept study, figures of merit reach 90% levels for classifying the clinical phases and demonstrate the power of the technology as an innovative medical tool for diagnosing a perinatal adverse outcome.
Collapse
Affiliation(s)
- Ion Olaetxea
- CIC nanoGUNE BRTASan Sebastián20018Spain
- Department of Communications EngineeringUniversity of the Basque CountryBilbao48013Spain
| | - Hector Lafuente
- Biodonostia Health Research InstituteSan Sebastián20014Spain
| | | | - Ander Izeta
- Biodonostia Health Research InstituteSan Sebastián20014Spain
- Tecnun School of Engineering ‐ University of NavarraSan Sebastián20018Spain
| | - Ibon Jaunarena
- Biodonostia Health Research InstituteSan Sebastián20014Spain
| | - Andreas Seifert
- CIC nanoGUNE BRTASan Sebastián20018Spain
- IKERBASQUEBasque Foundation for ScienceBilbao48009Spain
| |
Collapse
|
4
|
Jain S, Acharya N. Fetal Wellbeing Monitoring – A Review Article. Cureus 2022; 14:e29039. [PMID: 36249607 PMCID: PMC9550204 DOI: 10.7759/cureus.29039] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/09/2022] [Accepted: 09/11/2022] [Indexed: 11/15/2022] Open
Abstract
While assessing maternal health is relatively easy, assessing fetal well-being has always been tricky. This has led to tremendous technological development in fetal well-being assessment, thus bridging the gap between biotechnology and antenatal medicine. It is broadly divided into early pregnancy, late pregnancy, and during labour assessment. While the early assessment involves genetic check-ups and malformations, the late pregnancy check-ups aim at delivering a healthy fetus at term by normal vaginal delivery. The early tests can be invasive or non-invasive. Non-invasive include cell-free fetal DNA assessment and fetal cell-based assessment. Invasive tests include amniocentesis and chorionic villous sampling. These are followed by chromosomal microarray and next-generation sequencing. Under this procedure, exome sequencing is done, which is either clinical or whole. Sequencing of the whole genome can also be done. A recent advancement is pre-implantation genetic testing. These are mainly useful in identifying monogenic disorders for which the locus causing disease is identified beyond any doubt. In late pregnancy, the most commonly used test is biophysical. It works on the principle that an increase in the fetal heart rate occurs in conjugation with fetal movements. The next widely employed technology is Doppler, which is used to know fetal heart rates, valve timing intervals, and umbilical artery waveforms. Cardiotocography is also widely used both during pregnancy and during labour. It measures the fetal heart rate while correlating it with uterine contractions. Wireless fetal and maternal heart monitoring and telemonitoring are recent upcoming fields.
Collapse
|
5
|
Xu Y, Wang H, Qiao Z. Precise Control of Self‐Assembly in Vivo Based on Polymer‐Peptide Conjugates. CHINESE J CHEM 2022. [DOI: 10.1002/cjoc.202200459] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Yin‐Sheng Xu
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology (NCNST), Center of Materials Science and Optoelectronics Engineering University of Chinese Academy of Sciences Beijing 100190 China
| | - Hao Wang
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology (NCNST), Center of Materials Science and Optoelectronics Engineering University of Chinese Academy of Sciences Beijing 100190 China
| | - Zeng‐Ying Qiao
- CAS Key Laboratory for Biomedical Effects of Nanomaterials and Nanosafety, CAS Center for Excellence in Nanoscience, National Center for Nanoscience and Technology (NCNST), Center of Materials Science and Optoelectronics Engineering University of Chinese Academy of Sciences Beijing 100190 China
| |
Collapse
|
6
|
Murata T, Kyozuka H, Yasuda S, Fukuda T, Tanaka T, Fujimori K. Effects of maternal ritodrine hydrochloride administration on the heart rate of preterm fetal sheep with intraamniotic inflammation. PLoS One 2022; 17:e0265872. [PMID: 35358222 PMCID: PMC8970407 DOI: 10.1371/journal.pone.0265872] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Accepted: 03/04/2022] [Indexed: 11/18/2022] Open
Abstract
Ritodrine hydrochloride is used for pregnancy prolongation and intrauterine fetal resuscitation. However, its clinical significance in intraamniotic inflammation during preterm labor and intrauterine fetal distress is unclear. We investigated the effects of maternal ritodrine hydrochloride administration (MRA; 200 μg/min for 2 h, followed by 800 μg/min for 2 h after 24 h) on fetal physiological parameters. For this purpose, we used chronically instrumented pregnant sheep at 113–119 d (term = 145 d) of gestation without (Group 1, n = 5) and with (Group 2, n = 5) intraamniotic inflammation induced by lipopolysaccharide injection into the amniotic cavity. The changes in fetal heart rate (FHR) and short-term variability (STV) and long-term variability (LTV) in FHR, fetal blood pressure, and fetal arterial blood gas (FABG) values were measured before and at 1 and 2 h after initiating MRA. Before MRA, all parameters were similar between Groups 1 and 2; however, there was significantly higher STV in Group 2 than in Group 1 before MRA at 800 μg/min, significantly higher partial arterial pressure of carbon dioxide in FABG in Group 2 than in Group 1 before MRA at 200 μg/min, and significantly lower blood glucose (BG) in Group 2 than in Group 1 before MRA at 800 μg/min. One hour after MRA, the FHR, STV, and LTV were significantly higher at 800 μg/min than those at the baseline in Group 1, as determined by the Friedman test; however, no significant difference was observed in Group 2. Additionally, the FABG pH significantly decreased 1 h after MRA at 800 μg/min in Group 2, whereas FABG lactate and BG significantly increased 2 h after MRA at 800 μg/min in Groups 1 and 2. Thus, short-term MRA at 800 μg/min increased the FHR, STV, and LTV significantly; these values were further modified under intraamniotic inflammation.
Collapse
Affiliation(s)
- Tsuyoshi Murata
- Department of Obstetrics and Gynecology, Fukushima Medical University School of Medicine, Fukushima, Japan
- * E-mail:
| | - Hyo Kyozuka
- Department of Obstetrics and Gynecology, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - Shun Yasuda
- Department of Obstetrics and Gynecology, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - Toma Fukuda
- Department of Obstetrics and Gynecology, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - Teruyoshi Tanaka
- Department of Biomolecular Science, Fukushima Medical University School of Medicine, Fukushima, Japan
| | - Keiya Fujimori
- Department of Obstetrics and Gynecology, Fukushima Medical University School of Medicine, Fukushima, Japan
| |
Collapse
|
7
|
Lafuente H, Olaetxea I, Valero A, Alvarez FJ, Izeta A, Jaunarena I, Seifert A. Identification of Hypoxia-Ischemia by chemometrics considering systemic changes of the physiology. IEEE J Biomed Health Inform 2022; 26:2814-2821. [PMID: 35015657 DOI: 10.1109/jbhi.2022.3142190] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Perinatal asphyxia represents a major medical disorder and is related to around a fourth of all neonatal deaths worldwide. Specific thresholds for lactate or pH levels define the gold standard for detecting hypoxic-ischemic events as physiological abnormalities. In contrast to current gold standard, we analyze the systemic picture, represented by the whole set of biochemical parameters from blood gas analysis, by multiparametric machine learning algorithms. In a swine model with 22 objects, we investigate the impact of neonatal hypoxic-ischemic encephalopathy on 18 individual physiological parameters. In a first approach, we study the statistical significance of individual parameters by univariate analysis methods. In a second approach, we take the most relevant parameters as input for the development of predictive models by different hybrid and non hybrid classification algorithms. The predictive power of our multiparametric models outperforms by far the limited performance of pH and lactate as reliable indicators, despite strong correlation with hypoxic-ischemic events. We have been able to detect hypoxic-ischemic events even one hour after the episode, with accuracies close to 100% in contrast to pH or lactate-based diagnosis with 62% and 78%, respectively. By all machine learning algorithms, lactate is recognized as the main contributor due to its longer-term evidence of hypoxia-ischemia episodes. However, substantial improvement of the diagnosis is achieved by predictions based on a systemic picture of different physiological parameters. Our results prove the potential applicability of our method as a support tool for decision-making that will allow obstetricians to identify hypoxic ischemic episodes more accurately during labor.
Collapse
|
8
|
Gyllencreutz E, Varli IH, Lindqvist PG, Holzmann M. Variable deceleration features and intrapartum fetal acidemia - The role of deceleration area. Eur J Obstet Gynecol Reprod Biol 2021; 267:192-197. [PMID: 34826666 DOI: 10.1016/j.ejogrb.2021.11.009] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2021] [Revised: 11/02/2021] [Accepted: 11/05/2021] [Indexed: 10/19/2022]
Abstract
OBJECTIVE In recent years deceleration area has received increasing attention as a potential predictor of intrapartum fetal hypoxia. In several studies, the area has been manually esteemed as triangular in shape, which might introduce bias. In addition, the commonly used outcome acidemia in umbilical artery is affected by mode of delivery. We wanted to investigate the association between the variable deceleration features area, duration, depth and cumulative deceleration area (30 and 60 min) and intrapartum fetal acidemia measured as lactate concentration at fetal scalp blood sampling (FBS) in immediate connection to the decelerations. STUDY DESIGN In the source population of 1070 labors at Karolinska University Hospital, Sweden, with FBS performed on indication, we found 507 fetuses with predominantly variable decelerations as the indication for FBS. We examined the last 60- and 30-minutes of fetal monitoring preceding the FBS with focus on deceleration area, duration and depth. The contours of the decelerations were outlined manually but the area was calculated with a computer software program. We assessed area, duration and depth both as mean values per deceleration and as cumulative values during the time period of interest. We analyzed Pearson correlations and area under receiver operating characteristics curves (AUC). We also performed an adjusted analysis, with baseline frequency, variability, and accelerations as covariates. RESULTS Deceleration area and duration were the best predictors of intrapartum fetal acidemia (fetal lactate concentration >4.8 mmol/L measured with Lactate Pro™) with AUCs of 0.671 (0.682) and 0.678 (0.683) for cumulative measures during 30 (60) minutes prior to FBS, compared to deceleration depth with AUC of 0.632 (0.631). Corresponding Pearson correlations in 30-min (60-min) groups were 0.329 (0.335) and 0.358 (0.354) for deceleration area and duration and 0.212 (0.204) for deceleration depth. Using 250 beats cumulative cut-off for deceleration area during last 30 min, 71% vs. 43% were acidemic and non-acidemic, odds ratio = 3.2 (95% CI 1.7-6.1). CONCLUSIONS Deceleration area and duration were better predictors of intrapartum fetal acidemia than deceleration depth. Cumulative deceleration area >250 beats during 30 min was associated with three-fold higher odds of intrapartum acidemia compared to <250 beats.
Collapse
Affiliation(s)
- Erika Gyllencreutz
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden; Department of Obstetrics and Gynecology, Östersund Hospital, Region Jämtland Härjedalen, Sweden
| | - Ingela Hulthén Varli
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden; Medical Unit Pregnancy and Childbirth, Karolinska University Hospital, Stockholm, Sweden
| | - Pelle G Lindqvist
- Department of Clinical Sciences and Education, Sodersjukhuset, Karolinska Institutet, Stockholm, Sweden
| | - Malin Holzmann
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden; Medical Unit Pregnancy and Childbirth, Karolinska University Hospital, Stockholm, Sweden.
| |
Collapse
|
9
|
Rivolta MW, Barbieri M, Stampalija T, Sassi R, Frasch MG. Relationship Between Deceleration Morphology and Phase Rectified Signal Averaging-Based Parameters During Labor. Front Med (Lausanne) 2021; 8:626450. [PMID: 34901040 PMCID: PMC8655232 DOI: 10.3389/fmed.2021.626450] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2020] [Accepted: 10/31/2021] [Indexed: 01/03/2023] Open
Abstract
During labor, uterine contractions trigger the response of the autonomic nervous system (ANS) of the fetus, producing sawtooth-like decelerations in the fetal heart rate (FHR) series. Under chronic hypoxia, ANS is known to regulate FHR differently with respect to healthy fetuses. In this study, we hypothesized that such different ANS regulation might also lead to a change in the FHR deceleration morphology. The hypothesis was tested in an animal model comprising nine normoxic and five chronically hypoxic fetuses that underwent a protocol of umbilical cord occlusions (UCOs). Deceleration morphologies in the fetal inter-beat time interval (FRR) series were modeled using a trapezoid with four parameters, i.e., baseline b, deceleration depth a, UCO response time τ u and recovery time τ r . Comparing normoxic and hypoxic sheep, we found a clear difference for τ u (24.8±9.4 vs. 39.8±9.7 s; p < 0.05), a (268.1±109.5 vs. 373.0±46.0 ms; p < 0.1) and Δτ = τ u - τ r (13.2±6.9 vs. 23.9±7.5 s; p < 0.05). Therefore, the animal model supported the hypothesis that hypoxic fetuses have a longer response time τ u and larger asymmetry Δτ as a response to UCOs. Assessing these morphological parameters during labor is challenging due to non-stationarity, phase desynchronization and noise. For this reason, in the second part of the study, we quantified whether acceleration capacity (AC), deceleration capacity (DC), and deceleration reserve (DR), computed through Phase-Rectified Signal Averaging (PRSA, known to be robust to noise), were correlated with the morphological parameters. DC, AC and DR were correlated with τ u , τ r and Δτ for a wide range of the PRSA parameter T (Pearson's correlation ρ > 0.8, p < 0.05). In conclusion, deceleration morphologies have been found to differ between normoxic and hypoxic sheep fetuses during UCOs. The same difference can be assessed through PRSA based parameters, further motivating future investigations on the translational potential of this methodology on human data.
Collapse
Affiliation(s)
- Massimo W. Rivolta
- Dipartimento di Informatica, Università degli Studi di Milano, Milan, Italy
| | - Moira Barbieri
- Unit of Fetal Medicine and Prenatal Diagnosis, Institute for Maternal and Child Health IRCCS Burlo Garofolo, Trieste, Italy
| | - Tamara Stampalija
- Unit of Fetal Medicine and Prenatal Diagnosis, Institute for Maternal and Child Health IRCCS Burlo Garofolo, Trieste, Italy
- Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy
| | - Roberto Sassi
- Dipartimento di Informatica, Università degli Studi di Milano, Milan, Italy
| | - Martin G. Frasch
- Department of Obstetrics and Gynecology and Center on Human Development and Disability (CHDD), School of Medicine, University of Washington, Seattle, WA, United States
| |
Collapse
|
10
|
Iorizzo L, Carlsson Y, Johansson C, Berggren R, Herbst A, Wang M, Leiding M, Isberg PE, Kristensen K, Wiberg-Itzel E, McGee T, Wiberg N. Proposed cutoff for fetal scalp blood lactate in intrapartum fetal surveillance based on neonatal outcomes: a large prospective observational study. BJOG 2021; 129:636-646. [PMID: 34555249 DOI: 10.1111/1471-0528.16924] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/10/2021] [Indexed: 11/30/2022]
Abstract
OBJECTIVE Determination of lactate in fetal scalp blood (FBS) during labour has been recognised since the 1970s. The internationally accepted cutoff of >4.8 mmol/l indicating fetal acidosis is exclusive for the point-of-care device (POC) LactatePro™, which is no longer in production. The aim of this study was to establish a new cutoff for scalp lactate based on neonatal outcomes with the use of the StatstripLactate® /StatstripXpress® Lactate system, the only POC designed for hospital use. DESIGN Observational study. SETTING January 2016 to March 2020 labouring women with indication for FBS were prospectively included from seven Swedish and one Australian delivery unit. POPULATION Inclusion criteria: singleton pregnancy, vertex presentation, ≥35+0 weeks of gestation. METHOD Based on the optimal correlation between FBS lactate and cord pH/lactate, only cases with ≤25 minutes from FBS to delivery were included in the final calculations. MAIN OUTCOME MEASURES Metabolic acidosis in cord blood defined as pH <7.05 plus BDecf >10 mmol/l and/or lactate >10 mmol/l. RESULTS A total of 3334 women were enrolled of whom 799 were delivered within 25 minutes. The areas under the receiver operating characteristics curves (AUC) and corresponding optimal cutoff values were as follows; metabolic acidosis AUC 0.87 (95% CI 0.77-0.97), cutoff 5.7 mmol/l; pH <7.0 AUC 0.83 (95% CI 0.68-0.97), cutoff 4.6 mmol/l; pH <7.05 plus BDecf ≥12 mmol/l AUC 0.97 (95% CI 0.92-1), cutoff 5.8 mmol/l; Apgar score <7 at 5 minutes AUC 0.74 (95% CI 0.63-0.86), cutoff 5.2 mmol/l; and pH <7.10 plus composite neonatal outcome AUC 0.76 (95% CI 0.67-0.85), cutoff 4.8 mmol/l. CONCLUSION A scalp lactate level <5.2 mmol/l using the StatstripLactate® /StatstripXpress® system will safely rule out fetal metabolic acidosis. TWEETABLE ABSTRACT Scalp blood lactate <5.2 mmol/l using the StatstripLactate® /StatstripXpress system has an excellent ability to rule out fetal acidosis.
Collapse
Affiliation(s)
- L Iorizzo
- Department of Clinical Sciences Lund, Lund University, Lund, Sweden.,Department of Obstetrics and Gynaecology, Helsingborg Hospital, Helsingborg, Sweden
| | - Y Carlsson
- Department of Obstetrics and Gynaecology, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg, Sweden.,Centre of Perinatal Medicine and Health, Institute of Clinical Sciences, Sahlgrenska Academy, Gothenburg, Sweden
| | - C Johansson
- Department of Obstetrics and Gynaecology, Ystad lasarett, Ystad, Sweden
| | - R Berggren
- Department of Obstetrics and Gynaecology, Region Västra Götaland, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - A Herbst
- Department of Clinical Sciences Lund, Lund University, Lund, Sweden.,Department of Obstetrics and Gynaecology, Skåne University Hospital, Skåne, Sweden
| | - M Wang
- Department of Obstetrics and Gynaecology, Westmead Hospital, Sydney, NSW, Australia.,The University of Sydney, Sydney, NSW, Australia
| | - M Leiding
- Department of Obstetrics and Gynaecology, Skåne University Hospital, Skåne, Sweden
| | - P-E Isberg
- Department of Statistics, Lund University, Lund, Sweden
| | - K Kristensen
- Department of Clinical Sciences Lund, Lund University, Lund, Sweden.,Department of Obstetrics and Gynaecology, Gold Coast University Hospital, Gold Coast, Qld, Australia
| | - E Wiberg-Itzel
- Department of Obstetrics and Gynaecology, Söder Hospital, Stockholm, Sweden.,Institute of Karolinska, Stockholm, Sweden
| | - T McGee
- Department of Obstetrics and Gynaecology, Westmead Hospital, Sydney, NSW, Australia.,The University of Sydney, Sydney, NSW, Australia
| | - N Wiberg
- Department of Obstetrics and Gynaecology, Ystad lasarett, Ystad, Sweden.,Department of Clinical Sciences Malmö, Lund University, Lund, Sweden
| |
Collapse
|
11
|
Holzmann M, Nordström L, Steer P. Inconsistency between lactate meters in the assessment of fetal metabolic acidemia. Acta Obstet Gynecol Scand 2021; 100:815-817. [PMID: 33870498 DOI: 10.1111/aogs.14140] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2020] [Revised: 02/26/2021] [Accepted: 03/04/2021] [Indexed: 11/29/2022]
Affiliation(s)
- Malin Holzmann
- Medical Unit of Pregnancy and Delivery Care, Karolinska University Hospital, Stockholm, Sweden.,Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Lennart Nordström
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden
| | - Philip Steer
- Academic Department of Obstetrics and Gynaecology, Chelsea and Westminster Hospital, Imperial College London, London, UK
| |
Collapse
|
12
|
Ekengård F, Cardell M, Herbst A. Impaired validity of the new FIGO and Swedish CTG classification templates to identify fetal acidosis in the first stage of labor. J Matern Fetal Neonatal Med 2021; 35:4853-4860. [PMID: 33406946 DOI: 10.1080/14767058.2020.1869931] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
INTRODUCTION Cardiotocography (CTG) is the main method of intrapartum fetal surveillance. In 2015 a new guideline was introduced by the International Federation of Gynecology and Obstetrics (FIGO), FIGO-15. In Sweden it was adjusted to SWE-17, replacing the previous national template, SWE-09. This study, conducted at one university hospital and one regional hospital in southern Sweden, evaluated the diagnostic validity of these three templates to detect fetal acidosis during the first stage of labor. MATERIAL AND METHODS A total of 73 neonates with pH <7.1 in umbilical cord artery or vein at cesarean delivery during the first stage of labor were identified retrospectively. For each acidotic neonate, three non-acidemic neonates, with a pH ≥7.2 in cord artery and vein, and Apgar scores ≥9 at five and ten minutes, in all 219 neonates, were selected. The CTG tracings before birth in acidemic neonates, and tracings at the same cervical dilatation in the non-acidemic neonates, were independently assessed by three professionals from the obstetric staff, blinded to group and clinical data. Based on their categorizations of the included variables (baseline, variability, accelerations, decelerations and contraction rate), each CTG tracing was systematically classified according to the three templates. The sensitivity and specificity to identify acidemia by the classification pathological were determined for each template. Interobserver agreement in the assessments of tracings as pathological or not was analyzed, using free-marginal Kappa index. RESULTS The sensitivity for patterns classified as pathological to identify acidemia was similar for FIGO-15 (71%) and SWE-17 (77%, p = .13), and the specificity was 97% for both. SWE-09 had a significantly higher sensitivity (95%, p < .001) albeit with a lower specificity (90%, p < .001) than the other two templates. Among acidemic neonates, the fraction of tracings classified as normal was higher with SWE-17 (9.6%) than with SWE-09 (0%; p = .01) and FIGO-15 (1.4%; p = .06). For tracings from neonates with acidemia, agreement for three independent assessors was strong (κ 0.85) with SWE-09, and weak for FIGO-15 (κ 0.47), and SWE-17 (κ 0.51). For tracings from neonates without acidemia, the agreement was almost perfect for FIGO-15 (κ 0.91), strong withSWE-17 (κ 0.90) and moderate with SWE-09 (κ 0.78). CONCLUSIONS The ability of FIGO-15 and SWE-17 to identify fetal acidosis is considered insufficient. The combination of a high sensitivity and a high specificity makes SWE-09 the most discriminatory template during the first stage of labor.
Collapse
Affiliation(s)
- Frida Ekengård
- Department of Obstetrics, and Gynecology, Skåne University Hospital, Institution of Clinical Sciences Lund University, Lund, Sweden
| | - Monika Cardell
- Department of Obstetrics, and Gynecology, Skåne University Hospital, Institution of Clinical Sciences Lund University, Lund, Sweden
| | - Andreas Herbst
- Department of Obstetrics, and Gynecology, Skåne University Hospital, Institution of Clinical Sciences Lund University, Lund, Sweden
| |
Collapse
|
13
|
Prouhèze A, Girault A, Barrois M, Lepercq J, Goffinet F, Le Ray C. Fetal scalp blood sampling: Do pH and lactates provide the same information? J Gynecol Obstet Hum Reprod 2020; 50:101964. [PMID: 33130281 DOI: 10.1016/j.jogoh.2020.101964] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Revised: 10/20/2020] [Accepted: 10/22/2020] [Indexed: 10/23/2022]
Abstract
OBJECTIVE Assess the discordance between scalp pH and lactates performed from the same sample during labor. METHOD This single-center retrospective study included all women with a singleton fetus who had at least one fetal blood sample taken during labor. Some of them had up to seven samples. Scalp pH was the reference parameter for obstetric decision-making. The correlation between the pH and lactates was studied using Pearson coefficient. By categorizing the values as normal, pre-acidosis and acidosis, we were able to estimate agreement with Cohen's kappa coefficient. The frequency of discordance in the categorization and the factors related to it were studied with univariate and multivariable analyses. Cases of severe acidosis at birth (cord pH < 7.00) and cases with acidosis scalp lactates but normal scalp pH were analyzed. RESULTS We analyzed 480 samples from 268 fetuses among the 2644 deliveries during the study periode. Fetal blood sampling represented 10 % of deliveries. The scalp pH and lactates results were strongly correlated (r=-0.83), but their agreement was only fair (K = 0.36). In 29.4 % of cases, pH and lactates were discordant. Factors related to discordance were meconium-stained fluid, sampling at full dilation and multiple sampling. Six infants (2.2 %) had severe acidosis at birth. Cases' analyses did not allow to conclude severe acidosis could have been avoided using scalp lactates for obstetric decision-making. CONCLUSION For more than a quarter of the samples, results were discordant between scalp pH and lactates, especially when cervix was full dilated and when the amniotic fluid was meconium-stained. A randomized controlled trial comparing the relevance of each parameter according to the obstetrical situation would be necessary.
Collapse
Affiliation(s)
- Audrey Prouhèze
- Maternity of Port-Royal, AP-HP. APHP., Paris University Center, FHU PREMA, Paris, France.
| | - Aude Girault
- Maternity of Port-Royal, AP-HP. APHP., Paris University Center, FHU PREMA, Paris, France; Paris University, INSERM U1153, Obstetrical Perinatal and Pediatric Epidemiology Research Team (EPOPé), Center of Research on Epidemiology and Statisctics Sorbonne Paris Cité (CRESS), Paris, France
| | - Mathilde Barrois
- Maternity of Port-Royal, AP-HP. APHP., Paris University Center, FHU PREMA, Paris, France
| | - Jacques Lepercq
- Maternity of Port-Royal, AP-HP. APHP., Paris University Center, FHU PREMA, Paris, France
| | - François Goffinet
- Maternity of Port-Royal, AP-HP. APHP., Paris University Center, FHU PREMA, Paris, France; Paris University, INSERM U1153, Obstetrical Perinatal and Pediatric Epidemiology Research Team (EPOPé), Center of Research on Epidemiology and Statisctics Sorbonne Paris Cité (CRESS), Paris, France
| | - Camille Le Ray
- Maternity of Port-Royal, AP-HP. APHP., Paris University Center, FHU PREMA, Paris, France; Paris University, INSERM U1153, Obstetrical Perinatal and Pediatric Epidemiology Research Team (EPOPé), Center of Research on Epidemiology and Statisctics Sorbonne Paris Cité (CRESS), Paris, France
| |
Collapse
|
14
|
Tigchelaar F, Groen H, Westgren M, Huinink KD, Cremers T, van den Berg PP. A new microdialysis probe for continuous lactate measurement during fetal monitoring: Proof of concept in an animal model. Acta Obstet Gynecol Scand 2020; 99:1411-1416. [PMID: 32274792 PMCID: PMC7540415 DOI: 10.1111/aogs.13865] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2019] [Revised: 03/28/2020] [Accepted: 03/31/2020] [Indexed: 01/11/2023]
Abstract
INTRODUCTION Cardiotocography (CTG) is currently the most commonly used method for intrapartum fetal monitoring during labor. However, a high false-positive rate of fetal acidosis indicated by CTG leads to an increase in obstetric interventions. We developed a microdialysis probe that is integrated into a fetal scalp electrode allowing continuous measurement of lactate subcutaneously, thus giving instant information about the oxygenation status of the fetus. Our aim was to establish proof of concept in an animal model using a microdialysis probe to monitor lactate subcutaneously. MATERIAL AND METHODS We performed an in vivo study in adult male wild-type Wistar rats. We modified electrodes used for CTG monitoring in human fetuses to incorporate a microdialysis membrane. Optimum flow rates for microdialysis were determined in vitro. For the in vivo experiment, a microdialysis probe was inserted into the skin on the back of the animal. De-oxygenation and acidosis were induced by lowering the inspiratory oxygen pressure. Oxygenation and heart rate were monitored. A jugular vein cannula was inserted to draw blood samples for analysis of lactate, pH, pco2 , and saturation. Lactate levels in dialysate were compared with plasma lactate levels. RESULTS Baseline blood lactate levels were around 1 mmol/L. Upon de-oxygenation, oxygen saturation fell to below 40% for 1 h and blood lactate levels increased 2.5-fold. Correlation of dialysate lactate levels with plasma lactate levels was 0.89 resulting in an R2 of .78 in the corresponding linear regression. CONCLUSIONS In this animal model, lactate levels in subcutaneous fluid collected by microdialysis closely reflected blood lactate levels upon transient de-oxygenation, indicating that our device is suitable for subcutaneous measurement of lactate. Microdialysis probe technology allows the measurement of multiple compounds in the dialysate, such as glucose, albumin, or inflammatory mediators, so this technique may offer the unique possibility to shed light on fetal physiology during the intrapartum period.
Collapse
Affiliation(s)
- Froukje Tigchelaar
- Faculty of Medical SciencesUniversity of GroningenGroningenthe Netherlands
| | - Henk Groen
- Department of EpidemiologyUniversity of GroningenUniversity Medical Center GroningenGroningenthe Netherlands
| | | | | | - Thomas Cremers
- CAN Holding B.V.Groningenthe Netherlands
- Department of Pharmaceutical AnalysisFaculty of Science and EngineeringUniversity of GroningenGroningenthe Netherlands
| | - Paul P. van den Berg
- Department of Obstetrics & GynecologyUniversity of GroningenUniversity Medical Center GroningenGroningenthe Netherlands
| |
Collapse
|
15
|
Zaigham M, Helfer S, Kristensen KH, Isberg PE, Wiberg N. Maternal arterial blood gas values during delivery: Effect of mode of delivery, maternal characteristics, obstetric interventions and correlation to fetal umbilical cord blood. Acta Obstet Gynecol Scand 2020; 99:1674-1681. [PMID: 32524582 DOI: 10.1111/aogs.13936] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 06/02/2020] [Accepted: 06/03/2020] [Indexed: 12/13/2022]
Abstract
INTRODUCTION Obstetricians routinely use biochemical parameters from non-pregnant women to assess the condition of the laboring mother. However, it is well known that pregnancy leads to significant physiological changes in most organ systems. The aim of this study was to determine normal values for maternal arterial blood gases during vaginal deliveries as compared with control values from planned cesarean sections. We also wanted to elucidate the effect of various maternal characteristics, mode of delivery and obstetric interventions on blood gas values. MATERIAL AND METHODS We carried out a randomly selected, prospective-observational cohort study of 250 women undergoing vaginal delivery and 58 women undergoing planned cesarean section at the Department of Obstetrics and Gynecology, Skåne University Hospital, Malmö, Sweden. RESULTS We found significant differences for gestational age, parity, umbilical venous blood pH, pCO2 and lactate values between the two study groups (P < .005). Significantly lower pH, pCO2 , pO2 and sO2 were found in mothers delivering vaginally. Higher base deficit, hemoglobin, bilirubin, potassium, glucose and lactate were found in vaginal deliveries than in planned cesarean sections (P < .02). Maternal body mass index (BMI), smoking and hypertension were not significantly correlated to acid base parameters in women with vaginal deliveries. On the other hand, multiple regression showed significant associations for the use of epidural anesthesia on maternal pH (P < .05) and pO2 (P < .01); and synthetic oxytocin on pCO2 (P = .08), glucose (P < .00) and lactate (P < .02) levels in maternal arterial blood. Maternal arterial pH, pCO2 and lactate values correlated significantly to values in venous umbilical cord blood (P < .000). CONCLUSIONS Maternal arterial blood gas parameters varied significantly according to mode of delivery, the use of epidural anesthesia and synthetic oxytocin.
Collapse
Affiliation(s)
- Mehreen Zaigham
- Department of Obstetrics and Gynecology, Institution of Clinical Sciences Malmö, Lund University, Lund, Sweden
| | - Sara Helfer
- Department of Obstetrics and Gynecology, Institution of Clinical Sciences Malmö, Lund University, Lund, Sweden
| | - Karl Heby Kristensen
- Department of Obstetrics and Gynecology, Institution of Clinical Sciences Malmö, Lund University, Lund, Sweden
| | | | - Nana Wiberg
- Department of Obstetrics and Gynecology, Institution of Clinical Sciences Malmö, Lund University, Lund, Sweden.,Department of Gynecology and Obstetrics, Skåne University Hospital, Ystad, Sweden
| |
Collapse
|
16
|
Stål I, Wennerholm UB, Nordstrom L, Ladfors L, Wiberg-Itzel E. Fetal scalp blood sampling during second stage of labor - analyzing lactate or pH? A secondary analysis of a randomized controlled trial. J Matern Fetal Neonatal Med 2020; 35:1100-1107. [PMID: 32233704 DOI: 10.1080/14767058.2020.1743656] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Background: Cardiotocography (CTG) is a widely used method for assessing fetal wellbeing during labor. It is well-known that CTG has high sensitivity but low specificity. To avoid unnecessary operative interventions, adjunctive methods such as fetal blood sampling (FBS) are used. Few studies have looked into whether FBS can be used during second stage of labor, and in that case, which of the methods (lactate or pH) are preferred.Objective: To evaluate clinical effectiveness of measuring lactate versus pH in preventing birth acidemia when FBS was performed during second stage of labor.Methods: Secondary analysis of a randomized controlled trial . Thousand three hundred and thirty-eight women with a singleton pregnancy, cephalic presentation, gestational age ≥34 weeks, and indication for FBS during second stage of labor were included.Main outcome measures: Metabolic acidemia (pH <7.05 and base deficit >12 mmol/l) or pH < 7.00 in cord arterial blood at birth.Secondary outcomes: A composite outcome (metabolic acidemia, pH <7 or Apgar score <4), and rates of operative deliveries.Results: Metabolic acidemia occurred in 4.1% in the lactate versus 5.1% in the pH group (relative risk (RR): 0.80; 95% confidence interval (CI): 0.48-1.35) and pH <7 in 1.4% versus 2.8% (RR: 0.51, 95% CI: 0.23-1.13). Composite outcome was found in 3.8 versus 4.9%, respectively (RR: 0.76; 95% CI: 0.46-1.26). No difference in total operative interventions was found. More cesarean deliveries were performed in the lactate group (16.5 vs. 12.4%; RR: 1.33; 95% CI: 1.02-1.74).Conclusion: When analyzing lactate or pH in fetal scalp blood during second stage of labor neonatal outcomes were comparable. The frequency of total operative interventions was similar but more cesarean deliveries were performed in the lactate group.
Collapse
Affiliation(s)
- Ingrid Stål
- Department of Obstetrics and Gynecology, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Sahlgrenska University Hospital East, Gothenburg, Sweden
| | - Ulla-Britt Wennerholm
- Department of Obstetrics and Gynecology, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Sahlgrenska University Hospital East, Gothenburg, Sweden
| | - Lennart Nordstrom
- Department of Women and Children's Health, Karolinska Institute, Stockholm, Sweden.,Department of Pregnancy and Delivery, Karolinska University Hospital, Stockholm, Sweden
| | - Lars Ladfors
- Department of Obstetrics and Gynecology, Institute of Clinical Sciences at Sahlgrenska Academy, University of Gothenburg, Sahlgrenska University Hospital East, Gothenburg, Sweden
| | - Eva Wiberg-Itzel
- Department of Clinical Science and Education, Section of Obstetrics and Gynecology, Karolinska Institute, Womens clinic Sodersjukhuset, Stockholm, Sweden
| |
Collapse
|
17
|
Romanov AY, Prikhodko AM, Tysyachnyi OV, Baev OR, Yarotskaya EL, Sukhikh GT. Comparison of cord blood lactate measurement by gas analyzer and portable electrochemical devices. J Perinat Med 2020; 48:157-161. [PMID: 31821169 DOI: 10.1515/jpm-2019-0357] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/05/2019] [Accepted: 11/05/2019] [Indexed: 12/16/2022]
Abstract
Objective To compare the accuracy of cord blood lactate measurement using gas analyzer and portable devices in order to assess possibility of implementation of these devices in clinical practice. Methods We performed a prospective observational study using 30 umbilical cord samples which were obtained immediately after birth. Portable electrochemical devices Lactate Scout (SensLab GmbH, Leipzig, Germany) and StatStrip Lactate (NOVA Biomedical, Waltham, MA, USA) were used to determine lactate level. A gas analyzer ABL800 FLEX (Radiometer Medical ApS, Brønshøj-Husum, Denmark) was used as a reference. Base excess (BE), pH, partial oxygen (pO2) and carbon dioxide (pCO2) pressure, hemoglobin (ctHb) and bilirubin (ctBl) levels were measured. Results The mean umbilical cord blood lactate level determined by the gas analyzer was 5.85 ± 2.66 mmol/L (ranging from 1.4 mmol/L to 13.4 mmol/L). Lactate level estimated by Lactate Scout was 5.66 ± 2.65 mmol/L and did not significantly differ from the reference method level (P = 0.2547). The mean lactate level determined by StatStrip Lactate was significantly lower than by the gas analyzer - 4.81 ± 2.38 mmol/L (P < 0.0001). Umbilical cord blood pH, BE, pO2 and pCO2, ctHb and ctBl levels did not affect the accuracy of the lactate measurement in absolute units (mmol/L). Conclusion Umbilical cord blood lactate level measured by StatStrip Lactate was lower than estimated by the ABL800 FLEX gas analyzer. This shows the necessity to develop decision-making reference points separately for each device. Umbilical cord blood pH, BE, pO2 and pCO2, ctHb and ctBl levels did not affect the accuracy of measurements by electrochemical portable devices.
Collapse
Affiliation(s)
- Andrey Yurievich Romanov
- Specialist of R&D Department, National Medical Research Center for Obstetrics, Gynecology and Perinatology Named after Academician V.I. Kulakov of the Ministry of Health of Russian Federation, Ac. Oparina Str. 4, 117997 Moscow, Russian Federation, Tel.: +7 (903) 158-94-00
| | - Andrey Mikhailovich Prikhodko
- Maternity Department, Department Obstetrics and Gynecology, Researcher of the Innovative Technologies Department of Obstetrics Institute, National Medical Research Center for Obstetrics, Gynecology and Perinatology Ministry of Healthcare of Russian Federation, Moscow, Russian Federation
| | - Oleg Vladimirovich Tysyachnyi
- Maternity Departments, National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I. Kulakov Ministry of Health of Russia, Moscow, Russian Federation
| | - Oleg Radomirovich Baev
- Maternity Department, National Medical Research Center for Obstetrics, Gynecology and Perinatology Ministry of Healthcare of the Russian Federation, Moscow, Russian Federation.,Department of Obstetrics, Gynecology, Perinatology, and Reproductology of I.N. Sechenov First Moscow State Medical University of Ministry of Healthcare of Russian Federation, Moscow, Russian Federation
| | - Ekaterina Lvovna Yarotskaya
- Department for International Cooperation, Research Center of Obstetrics, Gynecology and Perinatology, National Medical Research Center for Obstetrics, Gynecology and Perinatology Ministry of Healthcare of the Russian Federation, Moscow, Russian Federation
| | - Gennady Tikhonovich Sukhikh
- Russian Academy of Sciences, National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of Ministry of Healthcare of Russian Federation, Moscow, Russian Federation
| |
Collapse
|
18
|
Xu S, Mao M, Zhang S, Qian R, Shen X, Shen J, Wang X. A randomized double-blind study comparing prophylactic norepinephrine and ephedrine infusion for preventing maternal spinal hypotension during elective cesarean section under spinal anesthesia: A CONSORT-compliant article. Medicine (Baltimore) 2019; 98:e18311. [PMID: 31860981 PMCID: PMC6940128 DOI: 10.1097/md.0000000000018311] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND Studies have shown the efficacy of norepinephrine in the treatment of maternal hypotension during cesarean section by comparing it to treatment with phenylephrine. However, few studies have compared the efficacy of norepinephrine to ephedrine. METHODS Ninety-seven women undergoing elective cesarean section were administered norepinephrine at 4 μg/minute (group N; n = 48) or ephedrine at 4 mg/minute (group E; n = 49) immediately postspinal anesthesia, with an on-off titration to maintain systolic blood pressure (SBP) at 80% to 120% of baseline. A rescue bolus of 8 μg norepinephrine was given whenever SBP reached the predefined lower limit. Our primary outcome was the incidence of tachycardia. Secondary outcomes included the incidence of bradycardia, hypertension, hypotension, severe hypotension, hypotensive episodes, number of rescue top-ups, hemodynamic performance error including median performance error (MDPE), and median absolute performance error (MDAPE). Neonatal Apgar scores and umbilical arterial (UA) blood gas data were also collected. RESULTS Women in group N experienced fewer cases of tachycardia (4.2% vs 30.6%, P = .002, odds ratio: 0.11 [95% confidence interval, CI: 0.02-0.47]), a lower standardized heart rate (HR) (70.3 ± 11 vs 75 ± 11, P = .04, difference: 4.7 ± 2.2 [95% CI: 0.24-9.1]), and a lower MDPE for HR (1.3 ± 9.6 vs 8.4 ± 13.5 bpm, P = .003, difference: 3.1 ± 1.8 [95% CI: -0.6-6.7]). In addition, the lowest or the highest HR was lower in group N compared to group E (both P < .05). Meanwhile, the standardized SBP in group N was lower than that in group E (P = .04). For neonates, the UA blood gas showed a higher base excess (BE) and a lower lactate level in group N compared to E (both P < .001). Other hemodynamic variables, maternal, and neonatal outcomes were similar. CONCLUSION Infusion of 4 μg/minute norepinephrine presented fewer cases of tachycardia, less fluctuation and a lower HR compared to baseline values, as well as a less stressed fetal status compared to ephedrine infusion at 4 mg/minute. In addition, norepinephrine infusion presented a lower standardized SBP compared to ephedrine.
Collapse
Affiliation(s)
- Shiqin Xu
- Department of Anesthesiology, Women's Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital
| | - Mao Mao
- Department of Anesthesiology, Women's Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital
| | - Susu Zhang
- Department of Anesthesiology, Women's Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital
| | - Ruifeng Qian
- Department of Anesthesiology, Women's Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital
| | - Xiaofeng Shen
- Department of Anesthesiology, Women's Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital
| | - Jinchun Shen
- Department of Anesthesiology, Jinling Hospital, School of Medicine, Nanjing University, Nanjing, P.R. China
| | - Xian Wang
- Department of Anesthesiology, Women's Hospital of Nanjing Medical University, Nanjing Maternity and Child Health Care Hospital
| |
Collapse
|
19
|
Liston R, Sawchuck D, Young D. No. 197b-Fetal Health Surveillance: Intrapartum Consensus Guideline. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2019; 40:e298-e322. [PMID: 29680084 DOI: 10.1016/j.jogc.2018.02.011] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE This guideline provides new recommendations pertaining to the application and documentation of fetal surveillance in the intrapartum period that will decrease the incidence of birth asphyxia while maintaining the lowest possible rate of obstetrical intervention. Pregnancies with and without risk factors for adverse perinatal outcomes are considered. This guideline presents an alternative classification system for antenatal fetal non-stress testing and intrapartum electronic fetal surveillance to what has been used previously. This guideline is intended for use by all health professionals who provide intrapartum care in Canada. OPTIONS Consideration has been given to all methods of fetal surveillance currently available in Canada. OUTCOMES Short- and long-term outcomes that may indicate the presence of birth asphyxia were considered. The associated rates of operative and other labour interventions were also considered. EVIDENCE A comprehensive review of randomized controlled trials published between January 1996 and March 2007 was undertaken, and MEDLINE and the Cochrane Database were used to search the literature for all new studies on fetal surveillance antepartum. The level of evidence has been determined using the criteria and classifications of the Canadian Task Force on Preventive Health Care (Table 1). SPONSOR This consensus guideline was jointly developed by the Society of Obstetricians and Gynaecologists of Canada and the British Columbia Perinatal Health Program (formerly the British Columbia Reproductive Care Program or BCRCP) and was partly supported by an unrestricted educational grant from the British Columbia Perinatal Health Program. RECOMMENDATION 1: LABOUR SUPPORT DURING ACTIVE LABOUR: RECOMMENDATION 2: PROFESSIONAL ONE-TO ONE CARE AND INTRAPARTUM FETAL SURVEILLANCE: RECOMMENDATION 3: INTERMITTENT AUSCULTATION IN LABOUR: RECOMMENDATION 4: ADMISSION FETAL HEART TEST: RECOMMENDATION 5: INTRAPARTUM FETAL SURVEILLANCE FOR WOMEN WITH RISK FACTORS FOR ADVERSE PERINATAL OUTCOME: When a normal tracing is identified, it may be appropriate to interrupt the electronic fetal monitoring tracing for up to 30 minutes to facilitate periods of ambulation, bathing, or position change, providing that (1) the maternal-fetal condition is stable and (2) if oxytocin is being administered, the infusion rate is not increased (III-B). RECOMMENDATION 6: DIGITAL FETAL SCALP STIMULATION: RECOMMENDATION 7: FETAL SCALP BLOOD SAMPLING: RECOMMENDATION 8: UMBILICAL CORD BLOOD GASES: RECOMMENDATION 9: FETAL PULSE OXIMETRY: RECOMMENDATION 10: ST WAVEFORM ANALYSIS: RECOMMENDATION 11: INTRAPARTUM FETAL SCALP LACTATE TESTING.
Collapse
|
20
|
Liston R, Sawchuck D, Young D. N° 197b-Surveillance du bien-être fœtal : Directive consensus d'intrapartum. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2019; 40:e323-e352. [PMID: 29680085 DOI: 10.1016/j.jogc.2018.02.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
21
|
Al Wattar BH, Lakhiani A, Sacco A, Siddharth A, Bain A, Calvia A, Kamran A, Tiong B, Warwick B, MacMahon C, Marcus D, Long E, Coyle G, Lever GE, Michel G, Gopal G, Baig H, Price HL, Badri H, Stevenson H, Hoyte H, Malik H, Edwards J, Hartley J, Hemers J, Tamblyn J, Dalton JAW, Frost J, Subba K, Baxter K, Sivakumar K, Murphy K, Papadakis K, Bladon LR, Kasaven L, Manning L, Prior M, Ghosh M, Couch M, Altunel M, Pearce M, Cocker M, Stephanou M, Jie M, Mistry M, Wahby MO, Saidi NS, Ramshaw NL, Tempest N, Parker N, Tan PL, Johnson RL, Harris R, Tildesley R, Ram R, Painuly R, Cuffolo R, Bugeja R, Ngadze R, Grainger R, Gurung S, Mak S, Farrell S, Cowey S, Neary S, Quinn S, Nijjar SK, Kenyon S, Lamb S, Tracey S, Lee T, Kinsella T, Davidson T, Corr T, Sampson U, McQueen V, Smith WP, Castling Z. Evaluating the value of intrapartum fetal scalp blood sampling to predict adverse neonatal outcomes: A UK multicentre observational study. Eur J Obstet Gynecol Reprod Biol 2019; 240:62-67. [PMID: 31229725 DOI: 10.1016/j.ejogrb.2019.06.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2019] [Revised: 05/26/2019] [Accepted: 06/11/2019] [Indexed: 11/17/2022]
Abstract
OBJECTIVE To evaluate the value of fetal scalp blood sampling (FBS) as an adjunct test to cardiotocography, to predict adverse neonatal outcomes. STUDY DESIGN A multicentre service evaluation observational study in forty-four maternity units in the UK. We collected data retrospectively on pregnant women with singleton pregnancy who received FBS in labour using a standardised data collection tool. The primary outcome was prediction of neonatal acidaemia diagnosed as umbilical cord arterial pH < 7.05, the secondary outcomes were the prediction of Apgar scores<7 at 1st and 5th minutes and admission to the neonatal intensive care unit (NICU). We evaluated the correlation between the last FBS blood gas before birth and the umbilical cord blood and adjusted for time intervals. We constructed 2 × 2 tables to calculate the sensitivity, specificity, positive (PPV) and negative predictive value (NPV) and generated receiver operating curves to report on the Area Under the Curve (AUC). RESULTS In total, 1422 samples were included in the analysis; pH values showed no correlation (r = 0.001, p = 0.9) in samples obtained within an hour (n = 314), or within half an hour from birth (n = 115) (r=-0.003, p = 0.9). A suboptimal FBS pH value (<7.25) had a poor sensitivity (22%) and PPV (4.9%) to predict neonatal acidaemia with high specificity (87.3%) and NPV (97.4%). Similar performance was noted to predict Apgar scores <7 at 1st (sensitivity 14.5%, specificity 87.5%, PPV 23.4%, NPV 79.6%) and 5th minute (sensitivity 20.3%, specificity 87.4%, PPV 7.6%, NPV 95.6%), and admission to NICU (sensitivity 20.3%, specificity 87.5%, PPV 13.3%, NPV 92.1%). The AUC for FBS pH to predict neonatal acidaemia was 0.59 (95%CI 0.59-0.68, p = 0.3) with similar performance to predict Apgar scores<7 at 1st minute (AUC 0.55, 95%CI 0.51-0.59, p = 0.004), 5th minute (AUC 0.55, 95%CI 0.48-0.62, p = 0.13), and admission to NICU (AUC 0.58, 95%CI 0.52-0.64, p = 0.002). Forty-one neonates had acidaemia (2.8%, 41/1422) at birth. There was no significant correlation in pH values between the FBS and the umbilical cord blood in this subgroup adjusted for sampling time intervals (r = 0.03, p = 0.83). CONCLUSIONS As an adjunct tool to cardiotocography, FBS offered limited value to predict neonatal acidaemia, low Apgar Scores and admission to NICU.
Collapse
|
22
|
Iorizzo L, Persson KEM, Kristensen KH, Wiberg N. Reliability of the point-of care analyzer "StatStrip® Xpress™" for measurement of fetal blood lactate. Clin Chim Acta 2019; 495:88-93. [PMID: 30953612 DOI: 10.1016/j.cca.2019.04.003] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2018] [Revised: 03/04/2019] [Accepted: 04/02/2019] [Indexed: 11/16/2022]
Abstract
OBJECTIVES Measurement of lactate in fetal blood is used to assess the degree of anaerobic metabolism. The technical difficulties in obtaining enough scalp blood for analysis by a bloodgas-analyzer advocates for the use of a point-of-care device. StatStrip®Xpress™ (SSX) has shown promising properties but needs further evaluation before implementation into fetal surveillance. METHODS Arterial/venous umbilical cord blood from 112 newborns were analyzed simultaneously with SSX and the reference method ABL800™. From 321 fetuses with abnormal heart rate scalp blood was sampled and analyzed repeatedly with SSX. RESULTS ABL800™ -lactate ranged from 1.9-13.3 mmol/L in arterial to 1.5-10.2 mmol/L in venous cord blood with excellent correlation to SSX (R2 = 0.95). SSX-values were lower compared to the reference method ranging from -0.79 mmol/L for low values to -1.68 mmol/L for high values. The mean CV for SSX-values in cord respectively scalp blood was: lactate ≤3 mmol/L 7.1% respectively 8.4%; lactate >3 mmol/L 3.8% respectively 6.8%. Repeated measurements of the same sample with SSX where without significant difference in cord/scalp blood (p = 0.11). CONCLUSION SSX-lactate values were constantly lower but correlated excellent to the reference method. The reproducibility was good for cord and scalp blood. We suggest SSX as an attractive device for measurement of fetal lactate.
Collapse
Affiliation(s)
- Linda Iorizzo
- Department of Obstetrics and Gynecology, Skåne University Hospital, Sweden; Department of Clinical Sciences, Lund University, Malmö, Sweden
| | - Kristina E M Persson
- Department of Laboratory Medicine, Lund University, Skåne University Hospital, Sweden
| | | | - Nana Wiberg
- Department of Obstetrics and Gynecology, Skåne University Hospital, Sweden; Department of Clinical Sciences, Lund University, Malmö, Sweden.
| |
Collapse
|
23
|
Murray DM. Biomarkers in neonatal hypoxic-ischemic encephalopathy-Review of the literature to date and future directions for research. HANDBOOK OF CLINICAL NEUROLOGY 2019; 162:281-293. [PMID: 31324315 DOI: 10.1016/b978-0-444-64029-1.00013-8] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The widespread introduction of therapeutic hypothermia as a standard of care in hypoxic-ischemic encephalopathy (HIE) has brought increasing pressure on clinicians to make an early and accurate assessment of the degree of hypoxic injury (HI) that has occurred and the severity of the encephalopathy that will ensue. No single blood-based marker is currently robust enough to detect significant HI or predict outcome. However, research in the field has been active in the last 10 years and we know that HIE is associated with predictable alterations in the expression of a number of inflammatory proteins, neuron-specific proteins, metabolite pathways, and microRNA. These alterations evolve quickly over the first hours and days of life. Predictive power varies depending on the timing of measurement of the biomarker, the sample type, and the case mix of the cohort examined. Combining clinical data with biochemical measurements is currently the most likely path toward improved detection and prediction of outcome in neonatal HIE.
Collapse
Affiliation(s)
- Deirdre M Murray
- Department of Paediatrics and Child Health, University College Cork, Cork, Ireland.
| |
Collapse
|
24
|
Cummins G, Kremer J, Bernassau A, Brown A, Bridle HL, Schulze H, Bachmann TT, Crichton M, Denison FC, Desmulliez MPY. Sensors for Fetal Hypoxia and Metabolic Acidosis: A Review. SENSORS (BASEL, SWITZERLAND) 2018; 18:E2648. [PMID: 30104478 PMCID: PMC6111374 DOI: 10.3390/s18082648] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 07/30/2018] [Accepted: 08/02/2018] [Indexed: 12/11/2022]
Abstract
This article reviews existing clinical practices and sensor research undertaken to monitor fetal well-being during labour. Current clinical practices that include fetal heart rate monitoring and fetal scalp blood sampling are shown to be either inadequate or time-consuming. Monitoring of lactate in blood is identified as a potential alternative for intrapartum fetal monitoring due to its ability to distinguish between different types of acidosis. A literature review from a medical and technical perspective is presented to identify the current advancements in the field of lactate sensors for this application. It is concluded that a less invasive and a more continuous monitoring device is required to fulfill the clinical needs of intrapartum fetal monitoring. Potential specifications for such a system are also presented in this paper.
Collapse
Affiliation(s)
- Gerard Cummins
- Institute of Sensors, Signals and Systems, Heriot-Watt University, Riccarton EH14 4AS, Scotland, UK.
| | - Jessica Kremer
- Institute of Sensors, Signals and Systems, Heriot-Watt University, Riccarton EH14 4AS, Scotland, UK.
| | - Anne Bernassau
- Institute of Sensors, Signals and Systems, Heriot-Watt University, Riccarton EH14 4AS, Scotland, UK.
| | - Andrew Brown
- MRC Centre for Reproductive Health, Queen's Medical Research Institute, University of Edinburgh, Edinburgh EH16 4TJ, Scotland, UK.
| | - Helen L Bridle
- Institute of Sensors, Signals and Systems, Heriot-Watt University, Riccarton EH14 4AS, Scotland, UK.
| | - Holger Schulze
- Division of Infection and Pathway Medicine, Edinburgh Medical School, The Chancellor's Building, The University of Edinburgh, Edinburgh EH16 4SB, Scotland, UK.
| | - Till T Bachmann
- Division of Infection and Pathway Medicine, Edinburgh Medical School, The Chancellor's Building, The University of Edinburgh, Edinburgh EH16 4SB, Scotland, UK.
| | - Michael Crichton
- Institute of Mechanical, Processing and Energy Engineering, Heriot-Watt University, Riccarton EH14 4AS, Scotland, UK.
| | - Fiona C Denison
- MRC Centre for Reproductive Health, Queen's Medical Research Institute, University of Edinburgh, Edinburgh EH16 4TJ, Scotland, UK.
| | - Marc P Y Desmulliez
- Institute of Sensors, Signals and Systems, Heriot-Watt University, Riccarton EH14 4AS, Scotland, UK.
| |
Collapse
|
25
|
Einikyte R, Snieckuviene V, Ramasauskaite D, Panaviene J, Paliulyte V, Opolskiene G, Kazenaite E. The comparison of umbilical cord arterial blood lactate and pH values for predicting short-term neonatal outcomes. Taiwan J Obstet Gynecol 2018; 56:745-749. [PMID: 29241913 DOI: 10.1016/j.tjog.2017.10.007] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/01/2017] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVE Current clinical practice of assessing neonatal condition is based on evaluation of umbilical cord arterial blood pH value rather than lactate. However, evidence shows that lactate is direct and more predictive measurement than pH or at least of equal importance. This study is to assess and compare umbilical cord arterial lactate and pH values for predicting short-term neonatal outcomes. MATERIALS AND METHODS A retrospective cohort study was conducted at the tertiary level hospital, were arterial umbilical cord blood sampling was collected according to the standard procedures. Neonatal morbidity was registered if at least one of the following conditions was noted: Apgar score at 1 min after delivery was 6 or lower, resuscitation performed, including assisted ventilation and requirement of admission to neonatal intensive care unit. Mothers-newborns pairs were allocated into two groups: newborns exposed to perinatal hypoxia (group 1) and observed as healthy newborns (group 2). Receiver operating characteristics curves (ROC) were generated to assess the predictive ability of pH and lactate for the short-term neonatal outcomes. RESULTS 901 neonates born at ≥37 weeks of gestation were included. Newborns exposed to perinatal hypoxia (group 1) encompassed 39 (4.3%) patients, and observed as healthy (group 2) - 862 (95.7%). Arterial umbilical cord blood pH in group 1 was 7.160 ± 0.126 as compared to 7.314 ± 0.083 in group 2; p < 0.001. Mean arterial lactate was significantly higher in group 1 than group 2 (6.423 ± 2.335 as compared to 3.600 ± 1.833; p < 0.001). The difference between areas under ROC curves representing pH and lactate was not significant (0.848 and 0.831 respectively; p = 0.6132). CONCLUSION Umbilical cord arterial lactate and pH predicted short-term neonatal outcomes with similar efficacies.
Collapse
Affiliation(s)
- Ruta Einikyte
- Vilnius University, Faculty of Medicine, Vilnius 08661, Lithuania
| | - Vilija Snieckuviene
- Vilnius University, Faculty of Medicine, Clinic of Obstetrics and Gynecology, Vilnius 08661, Lithuania
| | - Diana Ramasauskaite
- Vilnius University, Faculty of Medicine, Clinic of Obstetrics and Gynecology, Vilnius 08661, Lithuania.
| | | | - Virginija Paliulyte
- Vilnius University, Faculty of Medicine, Clinic of Obstetrics and Gynecology, Vilnius 08661, Lithuania
| | - Gina Opolskiene
- Vilnius University, Faculty of Medicine, Clinic of Obstetrics and Gynecology, Vilnius 08661, Lithuania
| | - Edita Kazenaite
- Vilnius University, Faculty of Medicine, Centre of Hepatology, Gastroenterology and Dietetics, Vilnius 08661, Lithuania; Vilnius University Hospital Santara Clinics, Vilnius 08661, Lithuania
| |
Collapse
|
26
|
Lu K, Holzmann M, Abtahi F, Lindecrantz K, Lindqvist PG, Nordstrom L. Fetal heart rate short term variation during labor in relation to scalp blood lactate concentration. Acta Obstet Gynecol Scand 2018; 97:1274-1280. [PMID: 29799630 DOI: 10.1111/aogs.13390] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2018] [Accepted: 05/22/2018] [Indexed: 11/28/2022]
Abstract
INTRODUCTION Fetal heart rate short term variation (STV) decreases with severe chronic hypoxia in the antenatal period. However, only limited research has been done on STV during labor. We have tested a novel algorithm for a valid baseline estimation and calculated STV. To explore the value of STV during labor, we compared STV with fetal scalp blood (FBS) lactate concentration, an early marker in the hypoxic process. MATERIAL AND METHODS Software was developed which estimates baseline frequency using a novel algorithm and thereby calculates STV according to Dawes and Redman in up to four 30-minute blocks prior to each FBS. Cardiotocography traces from 1070 women in labor who had had FBS performed on 2134 occasions were analyzed. RESULTS In acidemic cases (lactate >4.8 mmol/L; Lactate Pro™), median STV 30 minutes prior to FBS was 7.10 milliseconds compared with 6.09 milliseconds in the preacidemic (4.2-4.8 mmol/L) and 5.23 milliseconds in the normal (<4.2 mmol/L) groups (P < .05). There was a positive correlation between lactate and STV (rho = 0.16-0.24; P < .05). Median lactate concentration in cases with STV <3.0 milliseconds (n = 160) was 2.3 mmol/L. When 2 FBS were performed within 60 minutes the change rate of lactate correlated to STV (rho = 0.33; P < .001). Cases with increasing lactate concentration had a median STV of 5.29 milliseconds vs 4.41 milliseconds in those with decreasing lactate (P < .001). CONCLUSIONS In the early stages of intrapartum hypoxia, STV increases, contrary to findings regarding chronic hypoxia in the antenatal period. The increase in the adrenergic surge is a likely explanation.
Collapse
Affiliation(s)
- Ke Lu
- School of Technology and Health, Royal Institute of Technology, Stockholm, Sweden
| | - Malin Holzmann
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.,Patient Area Pregnancy and Delivery Care, Karolinska University Hospital, Stockholm, Sweden
| | - Fahrad Abtahi
- Institute of Environmental Medicine, Karolinska Institutet, Stockholm, Sweden.,Department of Clinical Physiology, Karolinska University Hospital Huddinge, Stockholm, Sweden
| | - Kaj Lindecrantz
- School of Technology and Health, Royal Institute of Technology, Stockholm, Sweden.,Department of Clinical Science Intervention and Technology, Karolinska Institutet, Stockholm, Sweden
| | - Pelle G Lindqvist
- Patient Area Pregnancy and Delivery Care, Karolinska University Hospital, Stockholm, Sweden.,Department of Clinical Science Intervention and Technology, Karolinska Institutet, Stockholm, Sweden
| | - Lennart Nordstrom
- Department of Women's and Children's Health, Karolinska Institutet, Stockholm, Sweden.,Patient Area Pregnancy and Delivery Care, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
27
|
Wiberg N, Klausen TW, Tyrberg T, Nordström L, Wiberg-Itzel E. Infant outcome at four years of age after intrapartum sampling of scalp blood lactate for fetal assessment. A cohort study. PLoS One 2018; 13:e0193887. [PMID: 29570701 PMCID: PMC5865709 DOI: 10.1371/journal.pone.0193887] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2017] [Accepted: 02/16/2018] [Indexed: 11/19/2022] Open
Abstract
OBJECTIVE To correlate the value of lactate in fetal scalp blood at delivery and the outcomes of the offspring at four years of age. METHODS Cases where scalp blood lactate was taken within sixty minutes before delivery were identified from the randomized trial "Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress". Data were grouped according to the generally accepted cutoffs for normality, pre-acidemia, acidemia and concentrations above mean +2 SD during the second stage. The outcome measures included gross-/fine motor function, vision, hearing, speaking and cognitive disorders, signs of central motor damage and referral to specialized pediatric services. RESULTS 307 cases were available for final analyse. With normal scalp lactate concentration, the number of children with a diagnosed disorder was lower compared to the pre-acidemic/acidemic groups, although the findings were only significant for fine motor dysfunction (p = 0.036). Elevated lactate values were significantly associated with increased risk for a poorer capacity of attention and understanding of instructions (OR 1.37, 95% CI 1.07-1.74), and for fine motor dysfunction (OR 1.22, 95% CI 1.00-1.49) at the age of four. CONCLUSION Higher levels of lactate in fetal scalp blood seems to be associated with increased risk of an aberrant developmental outcome at four years of age in some areas.
Collapse
Affiliation(s)
- Nana Wiberg
- Department of Obstetrics and Gynecology, Skåne University Hospital, Lund, Sweden
- Department of Clinical Sciences, Lund University, Malmö, Sweden
| | | | - Tobias Tyrberg
- Department of Infectious Diseases, Sahlgrenska University Hospital, Goteborg, Sweden
| | - Lennart Nordström
- Department of Obstetrics and Gynecology, Karolinska University Hospital, Stockholm Sweden
- Department of Women’s and Children’s Health, Karolinska Institute, Stockholm, Sweden
| | - Eva Wiberg-Itzel
- Department of Clinical Science and Education, Section of Obstetrics and Gynecology, Karolinska Institutet, Sodersjukhuset, Stockholm, Sweden
| |
Collapse
|
28
|
Mohta M, Duggal S, Chilkoti GT. Randomised double-blind comparison of bolus phenylephrine or ephedrine for treatment of hypotension in women with pre-eclampsia undergoing caesarean section. Anaesthesia 2018. [DOI: 10.1111/anae.14268] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
Affiliation(s)
- M. Mohta
- Department of Anaesthesiology and Critical Care; University College of Medical Sciences and Guru Teg Bahadur Hospital; Delhi India
| | - S. Duggal
- Department of Anaesthesiology and Critical Care; University College of Medical Sciences and Guru Teg Bahadur Hospital; Delhi India
| | - G. T. Chilkoti
- Department of Anaesthesiology and Critical Care; University College of Medical Sciences and Guru Teg Bahadur Hospital; Delhi India
| |
Collapse
|
29
|
Wretler S, Nordström L, Graner S, Holzmann M. Risk factors for intrapartum acidemia - a cohort study. J Matern Fetal Neonatal Med 2017; 31:3232-3237. [PMID: 28812454 DOI: 10.1080/14767058.2017.1368074] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
PURPOSE Birth acidemia is associated with short- and long-term morbidity in the child. Optimal intrapartum surveillance and timely interventions may reduce the incidence of these outcomes. Knowledge about conditions which increase the risks might be beneficial for optimal care. The aim with this study was to identify factors which increased the risk for lactacidemia in fetal scalp blood. MATERIALS AND METHODS A secondary analysis of a cohort study performed at Karolinska University Hospital Stockholm Sweden between February 2009 and February 2011. The study population included 1070 women in labor where fetal scalp blood sampling (FBS) was performed. RESULTS In a univariate logistic regression analysis for lactate >4.8 mmol/L at FBS, minor language barriers (OR 2.54; 95%CI 1.26-5.11), active bearing down (OR 2.46; 95%CI 1.12-5.39) and maternal height <155 cm (OR 2.15; 95%CI 1.08-4.26) were found as risk factors. In a multivariate logistic regression analysis, minor language barriers (OR 2.21; 95%CI 1.05-4.67) and active pushing (OR 2.68; 95%CI 1.20-6.00) remained significant. CONCLUSIONS Language barriers, active pushing and short stature were found to be significant risk factors for intrapartum lactacidemia. In the group with minor language problems better use of interpreters might be beneficial.
Collapse
Affiliation(s)
- Stina Wretler
- a Department of Women's and Children's Health , Karolinska Institutet , Stockholm , Sweden.,b Department of Obstetrics and Gynecology , Karolinska University Hospital , Stockholm , Sweden
| | - Lennart Nordström
- a Department of Women's and Children's Health , Karolinska Institutet , Stockholm , Sweden.,b Department of Obstetrics and Gynecology , Karolinska University Hospital , Stockholm , Sweden
| | - Sophie Graner
- c Centre for Pharmacoepidemiology, Department of Medicine , Karolinska Institutet , Stockholm , Sweden
| | - Malin Holzmann
- a Department of Women's and Children's Health , Karolinska Institutet , Stockholm , Sweden.,b Department of Obstetrics and Gynecology , Karolinska University Hospital , Stockholm , Sweden
| |
Collapse
|
30
|
Wang M, Chua SC, Bouhadir L, Treadwell EL, Gibbs E, McGee TM. Point-of-care measurement of fetal blood lactate - Time to trust a new device. Aust N Z J Obstet Gynaecol 2017; 58:72-78. [DOI: 10.1111/ajo.12671] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2017] [Accepted: 06/14/2017] [Indexed: 11/28/2022]
Affiliation(s)
- Mandy Wang
- Department of Obstetrics and Gynaecology; Westmead Hospital; Sydney New South Wales Australia
- Sydney Medical School Westmead; University of Sydney; Sydney New South Wales Australia
| | - Seng C. Chua
- Department of Obstetrics and Gynaecology; Westmead Hospital; Sydney New South Wales Australia
- Sydney Medical School Westmead; University of Sydney; Sydney New South Wales Australia
| | - Lilain Bouhadir
- Department of Obstetrics and Gynaecology; Westmead Hospital; Sydney New South Wales Australia
- Sydney Medical School Westmead; University of Sydney; Sydney New South Wales Australia
| | - Erin L. Treadwell
- Sydney Medical School Westmead; University of Sydney; Sydney New South Wales Australia
| | - Emma Gibbs
- NHMRC Clinical Trials Centre; University of Sydney; Sydney New South Wales Australia
| | - Therese M. McGee
- Department of Obstetrics and Gynaecology; Westmead Hospital; Sydney New South Wales Australia
- Sydney Medical School Westmead; University of Sydney; Sydney New South Wales Australia
| |
Collapse
|
31
|
Cahill AG, Macones GA, Smyser CD, López JD, Inder TE, Mathur AM. Umbilical Artery Lactate Correlates with Brain Lactate in Term Infants. Am J Perinatol 2017; 34:535-540. [PMID: 27788532 PMCID: PMC5530875 DOI: 10.1055/s-0036-1593844] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
Objective The objective of this study was to determine the correlation between umbilical artery lactate with brain lactate in nonanomalous term infants. Study Design We performed a nested case-control study within an on-going prospective cohort of more than 8,000 consecutive singleton term (≥ 37 weeks) nonanomalous infants. Neonates underwent cerebral magnetic resonance imaging (MRI) within the first 72 hours of life. Cases (umbilical artery pH ≤ 7.10) were gender and race matched 1:3 to controls (umbilical artery pH > 7.20). Single voxel magnetic resonance spectroscopy (MRS), lactate, and N-acetyl aspartate (NAA) for normalization were calculated using Siemens software (Plano, TX). Linear regression estimated the association between incremental change in umbilical artery lactate and brain lactate, both directly and as a ratio with NAA. Results Of 175 infants who underwent MRI with spectral sequencing, 52 infants had detectable brain lactate. The 52 infants with brain lactate peaks had umbilical artery lactate values of 1.6 to 11.4 mmol/L. For every 1.0 mmol/L increase in umbilical artery lactate, there was an increase in brain lactate of 0.02, which remained significant even when corrected for NAA. Conclusion MRS measured brain lactate is significantly correlated with umbilical artery lactate in nonanomalous term infants, which may help explain the observed association between umbilical artery lactate and neurologic morbidity.
Collapse
Affiliation(s)
- Alison G. Cahill
- Department of Obstetrics and Gynecology, Washington University in St. Louis, St. Louis, Missouri
| | - George A. Macones
- Department of Obstetrics and Gynecology, Washington University in St. Louis, St. Louis, Missouri
| | - Christopher D. Smyser
- Division of Neurology, Department of Pediatrics, Washington University in St. Louis, St. Louis, Missouri
| | - Julia D. López
- Department of Obstetrics and Gynecology, Washington University in St. Louis, St. Louis, Missouri
| | - Terrie E. Inder
- Department of Pediatric Newborn Medicine, Brigham and Women’s Hospital, Boston, Massachusetts
| | - Amit M. Mathur
- Department of Pediatrics, Washington University in St. Louis, St. Louis, Missouri
| |
Collapse
|
32
|
Birgisdottir BT, Holzmann M, Varli IH, Graner S, Saltvedt S, Nordström L. Reference values for Lactate Pro 2™ in fetal blood sampling during labor: a cross-sectional study. J Perinat Med 2017; 45:321-325. [PMID: 27089399 DOI: 10.1515/jpm-2016-0027] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/26/2016] [Accepted: 02/08/2016] [Indexed: 11/15/2022]
Abstract
OBJECTIVE Lactate Pro™ (LP1) is the only lactate meter evaluated for fetal scalp blood sampling (FBS) in intrapartum use. The reference values for this meter are: normal value <4.2 mmol/L, preacidemia 4.2-4.8 mmol/L, and acidemia >4.8 mmol/L. The production of this meter has been discontinued. An updated version, Lactate Pro 2TM (LP2), has been launched and is shown to be differently calibrated. The aims of the study were to retrieve a conversion equation to convert lactate values in FBS measured with LP2 to an estimated value if using LP1 and to define reference values for clinical management when using LP2. STUDY DESIGN A cross-sectional study was conducted at a university hospital in Sweden. A total of 113 laboring women with fetal heart rate abnormalities on cardiotocography (CTG) had FBS carried out. Lactate concentration was measured bedside with both LP1 and LP2 from the same blood sample capillary. A linear regression model was constructed to retrieve a conversion equation to convert LP2 values to LP1 values. RESULTS LP2 measured higher values than LP1 in all analyses. We found that 4.2 mmol/L with LP1 corresponded to 6.4 mmol/L with LP2. Likewise, 4.8 mmol/L with LP1 corresponded to 7.3 mmol/L with LP2. The correlation between the analyses was excellent (Spearman's rank correlation, r=0.97). CONCLUSION We recommend the following guidelines when interpreting lactate concentration in FBS with LP2: <6.4 mmol/L to be interpreted as normal, 6.4-7.3 mmol/L as preacidemia indicating a follow-up FBS within 20-30 min, and >7.3 mmol/L as acidemia indicating intervention.
Collapse
Affiliation(s)
| | - Malin Holzmann
- Department of Obstetrics and Gynecology, Karolinska University Hospital, Stockholm
| | - Ingela Hulthén Varli
- Department of Obstetrics and Gynecology, Karolinska University Hospital, Stockholm
| | - Sofie Graner
- Department of Obstetrics and Gynecology, Karolinska University Hospital, Stockholm
| | - Sissel Saltvedt
- Department of Obstetrics and Gynecology, Karolinska University Hospital, Stockholm
| | - Lennart Nordström
- Department of Obstetrics and Gynecology, Karolinska University Hospital, Stockholm
| |
Collapse
|
33
|
Pascual Mancho J, Marti Gamboa S, Redrado Gimenez O, Crespo Esteras R, Rodriguez Solanilla B, Castan Mateo S. Diagnostic accuracy of fetal scalp lactate for intrapartum acidosis compared with scalp pH. J Perinat Med 2017; 45:315-320. [PMID: 27718493 DOI: 10.1515/jpm-2016-0044] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/07/2016] [Accepted: 09/01/2016] [Indexed: 11/15/2022]
Abstract
OBJECTIVE To determine the diagnostic accuracy of fetal scalp lactate sampling (FSLS) and to establish an optimal cut-off value for intrapartum acidosis compared with fetal scalp pH. METHODS A 20-month retrospective cohort study was conducted of all neonates delivered in our institution for whom fetal scalp blood sampling (FSBS) was performed, matching their intrapartum gasometry to their cord gasometry at delivery (n=243). The time taken from the performance of scalp blood sampling to arterial umbilical cord gas acquisition was 45 min at most. Five arterial cord gasometry patterns were set for assessing the predictive ability of both techniques. Subsequent obstetric management for a pathological value was analysed considering the use of both techniques. RESULTS The optimal cut-off value for FSLS was 4.8 mmol/L: this value has 100% sensitivity and 63% specificity for umbilical arterial cord gas pH≤7.0 and base deficit (BD)≥12 detection, and 100% sensitivity and 64% specificity for umbilical arterial cord gas pH≤7.10 and BD≥12 detection, with a false negative rate of <1.3%, improving fetal scalp pH performance. FSLS showed the best area under the curve (AUC) of 0.86 and 0.84 for both arterial cord gasometry patterns, respectively. Expedite birth following lactate criteria would have been the same as following pH criteria (92 obstetric interventions) with no cases of missed metabolic acidosis. In the cohort, 19.8% of cases were discordant, but no cases of metabolic acidosis were in this group. CONCLUSIONS FSLS improves the detection of metabolic acidosis via fetal scalp pH with an optimal cut-off value of 4.8 mmol/L. FSLS can be used without increasing obstetrical interventions or missing metabolic acidosis.
Collapse
Affiliation(s)
- Jara Pascual Mancho
- Departamento de Obstetricia, Hospital Universitario Miguel Servet, P° Isabel la Católica, Zaragoza 50009
| | - Sabina Marti Gamboa
- Departamento de Obstetricia, Hospital Universitario Miguel Servet, P° Isabel la Católica, Zaragoza 50009
| | - Olga Redrado Gimenez
- Departamento de Obstetricia, Hospital Universitario Miguel Servet, P° Isabel la Católica, Zaragoza 50009
| | - Raquel Crespo Esteras
- Departamento de Obstetricia, Hospital Universitario Miguel Servet, P° Isabel la Católica, Zaragoza 50009
| | - Belen Rodriguez Solanilla
- Departamento de Obstetricia, Hospital Universitario Miguel Servet, P° Isabel la Católica, Zaragoza 50009
| | - Sergio Castan Mateo
- Departamento de Obstetricia, Hospital Universitario Miguel Servet, P° Isabel la Católica, Zaragoza 50009
| |
Collapse
|
34
|
Decision-to-delivery interval: Is 30 min the magic time? What is the evidence? Does it work? Best Pract Res Clin Anaesthesiol 2017. [DOI: 10.1016/j.bpa.2017.04.001] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
35
|
Heinis A, van Dillen J, Oosting J, Rhöse S, Vandenbussche F, Van Drongelen J. Clinical evaluation of Statstrip®Lactate for use in fetal scalp blood sampling. Acta Obstet Gynecol Scand 2017; 96:334-341. [DOI: 10.1111/aogs.13078] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2016] [Accepted: 11/30/2016] [Indexed: 11/29/2022]
Affiliation(s)
- Ayesha Heinis
- Department of Obstetrics and Gynecology; Radboud University Medical Center; Nijmegen the Netherlands
| | - Jeroen van Dillen
- Department of Obstetrics and Gynecology; Radboud University Medical Center; Nijmegen the Netherlands
| | - Janine Oosting
- Department of Laboratory Medicine; Radboud University Medical Center; Nijmegen the Netherlands
| | - Sarah Rhöse
- Department of Obstetrics and Gynecology; Radboud University Medical Center; Nijmegen the Netherlands
| | - Frank Vandenbussche
- Department of Obstetrics and Gynecology; Radboud University Medical Center; Nijmegen the Netherlands
| | - Joris Van Drongelen
- Department of Obstetrics and Gynecology; Radboud University Medical Center; Nijmegen the Netherlands
| |
Collapse
|
36
|
Morin C, Chartier M, Bounan S, Hatem G, Goffinet F, Le Ray C. [Fetal scalp pH during labor: Which threshold for intervention?]. J Gynecol Obstet Hum Reprod 2017; 46:183-187. [PMID: 28403976 DOI: 10.1016/j.jogoh.2016.12.007] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2016] [Revised: 12/02/2016] [Accepted: 12/06/2016] [Indexed: 11/18/2022]
Abstract
OBJECTIVE In case of abnormal fetal heart rate, there is no consensus on the decision threshold pH scalp leading to a rapid birth. The objective of this study was to compare neonatal issues and cesarean rate in two maternity using different decision thresholds of scalp pH. MATERIAL AND METHODS A comparative retrospective study conducted in two level III maternity units between January 2013 and May 2014, one maternity unit used a decision threshold of 7.20 (maternity unit 7,20), and the other one a threshold of 7.25 (maternity unit 7,25). An adverse neonatal outcome was defined by a composite endpoint of neonatal morbidity. The risk of cesarean was assessed using a multivariate analysis. RESULTS One hundred and four patients were included in the maternity unit 7,20 and 163 patients in the maternity 7,25. Adverse neonatal outcome was similar in both maternities (25% vs. 30,1%; P=0.4). The average pH at birth was similar in both maternities, as well as the Apgar score at 5minutes and neonatal transfer rates. However, BE<-12 was more frequent in maternity using 7,20 scalp pH threshold (7% vs. 0%; P<0.01). The cesarean rate was higher in maternity 7,25 (adjusted OR=2.23 95% CI [1.17-4.25]). CONCLUSION It seems that a decisional threshold fixed to 7,20 could be used reasonably. It could allow to reduce cesarean rate. Other studies are, however, needed to confirm that such threshold of 7,20 does not increase the risk of severe acidosis.
Collapse
Affiliation(s)
- C Morin
- Maternité Port-Royal, hôpital Cochin, DHU risques et grossesse, Assistance publique-Hôpitaux de Paris, 53, avenue de l'Observatoire, 75014 Paris, France
| | - M Chartier
- Maternité Port-Royal, hôpital Cochin, DHU risques et grossesse, Assistance publique-Hôpitaux de Paris, 53, avenue de l'Observatoire, 75014 Paris, France
| | - S Bounan
- Département d'obstétrique et gynécologie, hôpital Delafontaine, 93200 Saint-Denis, France
| | - G Hatem
- Département d'obstétrique et gynécologie, hôpital Delafontaine, 93200 Saint-Denis, France
| | - F Goffinet
- Maternité Port-Royal, hôpital Cochin, DHU risques et grossesse, Assistance publique-Hôpitaux de Paris, 53, avenue de l'Observatoire, 75014 Paris, France
| | - C Le Ray
- Maternité Port-Royal, hôpital Cochin, DHU risques et grossesse, Assistance publique-Hôpitaux de Paris, 53, avenue de l'Observatoire, 75014 Paris, France.
| |
Collapse
|
37
|
Bullens LM, Moors S, van Runnard Heimel PJ, van der Hout-van der Jagt MB, Oei SG. Practice variation in the management of intrapartum fetal distress in The Netherlands and the Western world. Eur J Obstet Gynecol Reprod Biol 2016; 205:48-53. [DOI: 10.1016/j.ejogrb.2016.08.012] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2016] [Revised: 06/29/2016] [Accepted: 08/01/2016] [Indexed: 10/21/2022]
|
38
|
Moss TJM, Nitsos I, Harding R, Newnham JP. Differential Effects of Maternal and Fetal Betamethasone Injections in Late-Gestation Fetal Sheep. ACTA ACUST UNITED AC 2016. [DOI: 10.1016/s1071-55760300152-7] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Timothy J. M. Moss
- School of Women's and Infants' Health, University of Western Australia, Perth, Western Australia, Australia; Department of Pysiology, Monash University Clayton, Victoria, Australia; Lotteries Commission Perinatal Research Laboratories, School of Women's and Infants' Health. The University of Western Australia, Box M094, 35 Stirling Highway, Crawley, WA 6009 Australia
| | | | | | - John P. Newnham
- School of Women's and Infants' Health, University of Western Australia, Perth, Western Australia, Australia; Department of Pysiology, Monash University Clayton, Victoria, Australia
| |
Collapse
|
39
|
Umbilical Cord Venous Lactate for Predicting Arterial Lactic Acidemia and Neonatal Morbidity at Term. Obstet Gynecol 2016; 127:674-680. [PMID: 26959212 DOI: 10.1097/aog.0000000000001339] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To estimate the utility of umbilical venous lactate, more readily available than umbilical cord arterial lactate, for predicting arterial lactic acidemia and neonatal outcomes at term. METHODS This was a prospective cohort study of consecutive, nonanomalous, singleton, term births after labor in a large academic medical center (2009-2014). Umbilical arterial and venous lactate were measured immediately after delivery, before knowledge of neonatal outcomes. The outcome measures were arterial lactic acidemia (greater than 3.9 mmol/L) and a composite neonatal outcome consisting of neonatal death and any of a number of neonatal morbidities including intubation, mechanical ventilation, meconium aspiration syndrome, hypoxic-ischemic encephalopathy, and therapeutic hypothermia. Predictive ability of venous lactate was estimated using the area under the receiver operating characteristic curve. RESULTS Among 7,741 births, venous lactate was strongly predictive of arterial lactic acidemia (area under the curve 0.958). The "optimal" cut point of venous lactate for predicting both arterial lactic acidemia and the composite neonatal outcome was 3.4 mmol/L. This predicted arterial lactic acidemia with sensitivity of 87.0% and specificity of 91.3%. Positive and negative predictive values were 79.9% and 94.7%, respectively. The composite neonatal outcome occurred in 104 neonates (1.3%). Compared with arterial lactate, venous lactate predicted the composite neonatal outcome with comparable sensitivity (75.0% compared with 74.0%, P>.99) but slightly lower specificity (69.7% compared with 72.2%, P<.01). CONCLUSION Umbilical venous lactate strongly predicts arterial lactic acidemia and is comparable with arterial lactate for predicting neonatal morbidity at term. It could be used as a measure of neonatal morbidity when arterial blood is not available.
Collapse
|
40
|
Holzmann M, Wretler S, Nordström L. Absence of accelerations during labor is of little value in interpreting fetal heart rate patterns. Acta Obstet Gynecol Scand 2016; 95:1097-103. [PMID: 27301645 DOI: 10.1111/aogs.12939] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2016] [Accepted: 06/13/2016] [Indexed: 11/30/2022]
Abstract
INTRODUCTION The aim of this study was to investigate the correlation between increasing time since fetal heart rate (FHR) accelerations, positive (no acceleration) stimulation tests and fetal acidemia. MATERIAL AND METHODS Observational study of FHR recordings from 1070 laboring women with indication for fetal scalp blood sampling (FBS). FHR traces were scrutinized regarding acceleration at FBS and duration since most recent acceleration. The appraiser was blinded to the FBS result. RESULTS At the first sampling, 8.8% of fetuses had lactate concentration >4.8 mmol/L. There were no differences between those with recent accelerations (≤60 min), and absent accelerations (>60 min or never) prior to FBS (8.3% vs. 8.9%, p = 0.71). Corresponding analyses for subgroups were: fetuses with isolated absence of accelerations, 3.7% vs. 1.5% (p = 0.41), fetuses without decelerations (i.e. reduced variability and/or tachycardia), 6.1% vs. 5.1% (p = 0.81) and fetuses with serious decelerations (i.e. late or complicated variable), 15.0% vs. 16.1% (p = 0.87). Among fetuses with serious decelerations, increasing duration from most recent acceleration had a weak but statistically significant correlation to increased lactate concentration (rs = 0.12, p = 0.03). The positive likelihood ratio for acidemia with no response at FBS was 1.15. CONCLUSION In a population with FBS performed upon indication, there was no correlation between duration since last FHR acceleration and increased lactate concentration. The majority of fetuses are not acidemic even when the FHR trace is pathological and stimulation tests are only helpful when accelerations are provoked.
Collapse
Affiliation(s)
- Malin Holzmann
- Department of Women's and Children's Health, Karolinska Institute, Karolinska University Hospital, Stockholm, Sweden.
| | - Stina Wretler
- Department of Women's and Children's Health, Karolinska Institute, Karolinska University Hospital, Stockholm, Sweden
| | - Lennart Nordström
- Department of Women's and Children's Health, Karolinska Institute, Karolinska University Hospital, Stockholm, Sweden
| |
Collapse
|
41
|
Visser GH, Ayres-de-Campos D. FIGO consensus guidelines on intrapartum fetal monitoring: Adjunctive technologies. Int J Gynaecol Obstet 2016; 131:25-9. [PMID: 26433402 DOI: 10.1016/j.ijgo.2015.06.021] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Affiliation(s)
- Gerard H Visser
- Department of Obstetrics, University Medical Center, Utrecht, The Netherlands
| | - Diogo Ayres-de-Campos
- Medical School, Institute of Biomedical Engineering, S. Joao Hospital, University of Porto, Portugal
| | | |
Collapse
|
42
|
Wiberg N, Källén K. Fetal scalp blood lactate during second stage of labor: determination of reference values and impact of obstetrical interventions. J Matern Fetal Neonatal Med 2016; 30:612-617. [PMID: 27181136 DOI: 10.1080/14767058.2016.1181167] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
OBJECTIVE To determine the reference interval of fetal scalp blood lactate during second stage of labor. MATERIAL Two hundred and fifty-three women in first stage of labor with a reassuring CTG were asked for permission to sample fetal scalp blood during second stage. RESULTS In cases with reassuring CTG and five minute Apgar score ≥9, the mean lactate value (±2 SD) was 2.5 mmol/L (lower limit 1.1, higher limit 5.2). The lactate concentration was significantly higher among nulliparous and in cases with use of epidural or oxytocin (p <0.001). There was a moderate positive correlation between scalp lactate values and active pushing time. When parity, epidural, oxytocin and active pushing time were analyzed together, they had equal influence on lactate values (p <0.001). Higher lactate values were associated with intermediate/pathological CTG compared to normal CTG (p <0.001). There was no correlation to gestational age or birthweight (p = 0.72, respectively 0.43). CONCLUSIONS The reference interval of fetal scalp lactate during second stage is 1.1-5.2 mmol/L. Parity, use of epidural or oxytocin and the duration of pushing are associated to increased lactate concentration; however, we could not demonstrate any correlation to advancing gestational age or birthweight.
Collapse
Affiliation(s)
- Nana Wiberg
- a Department of Obstetrics and Gynecology , Skåne University Hospital , Lund , Sweden , and
| | - Karin Källén
- b Center for Reproductive Epidemiology, Tornblad Institute, Institution of Clinical Sciences Lund, Lund University , Lund , Sweden
| |
Collapse
|
43
|
East CE, Kane SC, Davey MA, Kamlin CO, Brennecke SP. Protocol for a randomised controlled trial of fetal scalp blood lactate measurement to reduce caesarean sections during labour: the Flamingo trial [ACTRN12611000172909]. BMC Pregnancy Childbirth 2015; 15:285. [PMID: 26531186 PMCID: PMC4632368 DOI: 10.1186/s12884-015-0709-7] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2015] [Accepted: 10/16/2015] [Indexed: 11/10/2022] Open
Abstract
BACKGROUND The rate of caesarean sections around the world is rising each year, reaching epidemic proportions. Although many caesarean sections are performed for concerns about fetal welfare on the basis of abnormal cardiotocography, the majority of babies are shown to be well at birth, meaning that the operation, with its inherent short and long term risks, could have been avoided without compromising the baby's health. Previously, fetal scalp blood sampling for pH estimation was performed in the context of an abnormal cardiotocograph, to improve the identification of babies in need of expedited delivery. This test has largely been replaced by lactate measurement, although its validity is yet to be established through a randomised controlled trial. This study aims to test the hypothesis that the performance of fetal scalp blood lactate measurement for women in labour with an abnormal cardiotocograph will reduce the rate of birth by caesarean section from 38 % to 25 % (a 35 % relative reduction). METHODS/DESIGN Prospective unblinded randomised controlled trial conducted at a single tertiary perinatal centre. Women labouring with a singleton fetus in cephalic presentation at 37 or more weeks' gestation with ruptured membranes and with an abnormal cardiotocograph will be eligible. Participants will be randomised to one of two groups: fetal monitoring by cardiotocography alone, or cardiotocography augmented by fetal scalp blood lactate analysis. Decisions regarding the timing and mode of delivery will be made by the treating team, in accordance with hospital protocols. The primary study endpoint is caesarean section with secondary outcomes collected from maternal, fetal and neonatal clinical course and morbidities. A cost effectiveness analysis will also be performed. A sample size of 600 will provide 90 % power to detect the hypothesised difference in the proportion of women who give birth by caesarean section. DISCUSSION This world-first trial is adequately powered to determine the impact of fetal scalp blood lactate measurement on rates of caesarean section. Preventing unnecessary caesarean sections will reduce the health and financial burdens associated with this operation, both in the index and any future pregnancies. TRIAL REGISTRATION Australian New Zealand Clinical Trials Registry ACTRN12611000172909.
Collapse
Affiliation(s)
- Christine E East
- Department of Obstetrics and Gynaecology, University of Melbourne & School of Nursing and Midwifery, Monash University, Parkville, 3052, Australia. .,Department of Perinatal Medicine, Pregnancy Research Centre, The Royal Women's Hospital, The University of Melbourne, Parkville, 3052, Australia. .,Department of Obstetrics and Gynaecology, The University of Melbourne, Parkville, 3052, Australia.
| | - Stefan C Kane
- Department of Perinatal Medicine, The Royal Women's Hospital, Parkville, 3052, Australia.
| | - Mary-Ann Davey
- Judith Lumley Centre (formerly Mother & Child Health Research), La Trobe University, 215 Franklin Street, Melbourne, VIC, 3000, Australia.
| | - C Omar Kamlin
- Neonatal Services, Royal Women's Hospital, Parkville, 3052, Australia.
| | - Shaun P Brennecke
- Department of Perinatal Medicine, Pregnancy Research Centre, The Royal Women's Hospital, The University of Melbourne, Parkville, 3052, Australia. .,Department of Obstetrics and Gynaecology, The University of Melbourne, Parkville, 3052, Australia.
| | | |
Collapse
|
44
|
|
45
|
Rørbye C, Perslev A, Nickelsen C. Lactate versus pH levels in fetal scalp blood during labor--using the Lactate Scout System. J Matern Fetal Neonatal Med 2015; 29:1200-4. [PMID: 26004985 DOI: 10.3109/14767058.2015.1045863] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To assess if lactate measured with the Scout Lactate System is a reliable alternative to pH in intrapartum monitoring of the fetus. METHODS A prospective study analyzing (1) the correlation between scalp lactate measured by the Scout Lactate System and the Automatic Blood Laboratory (ABL), (2) the correlation between lactate and pH measured in scalp blood and (3) the correlation between fetal scalp lactate and umbilical cord SBE. The sensitivity/specificity and positive/negative predictive values of lactate in predicting low pH were analyzed and expressed as Receiver Operating Curves (ROC). RESULTS Lactate measured by the Scout Lactate System and the ABL correlated well (r(2)=0.85). Both lactate and pH were measured in 1009 scalp blood samples. The sensitivity and specificity of lactate ≥ 4.8 mmol/l in predicting a pH <7.20 were 0.63 and 0.85, respectively. The correlation between scalp lactate measured within 15 min prior to delivery and the umbilical cord SBE was low. CONCLUSION Monitoring non-reassuring deliveries with scalp lactate instead of pH would have resulted in more (155 instead of 56) instrumental deliveries with no decrease in newborns with severe metabolic acidosis.
Collapse
Affiliation(s)
- Christina Rørbye
- a Department of Obstetrics and Gynecology , University of Copenhagen, Hvidovre Hospital , Hvidovre , Denmark
| | - Anette Perslev
- a Department of Obstetrics and Gynecology , University of Copenhagen, Hvidovre Hospital , Hvidovre , Denmark
| | - Carsten Nickelsen
- a Department of Obstetrics and Gynecology , University of Copenhagen, Hvidovre Hospital , Hvidovre , Denmark
| |
Collapse
|
46
|
East CE, Leader LR, Sheehan P, Henshall NE, Colditz PB, Lau R. Intrapartum fetal scalp lactate sampling for fetal assessment in the presence of a non-reassuring fetal heart rate trace. Cochrane Database Syst Rev 2015; 2015:CD006174. [PMID: 25929461 PMCID: PMC10823414 DOI: 10.1002/14651858.cd006174.pub3] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
BACKGROUND Fetal scalp blood sampling for lactate estimation may be considered following identification of an abnormal or non-reassuring fetal heart rate pattern. The smaller volume of blood required for this test, compared with the more traditional pH estimation, may improve sampling rates. The appropriate use of this practice mandates systematic review of its safety and clinical effectiveness prior to widespread introduction. OBJECTIVES To evaluate the effectiveness and risks of fetal scalp lactate sampling in the assessment of fetal well-being during labour, compared with no testing or alternative testing. SEARCH METHODS We searched the Cochrane Pregnancy and Childbirth Group's Trials Register (31 January 2015). SELECTION CRITERIA All published and unpublished randomised and quasi-randomised trials that compared fetal scalp lactate testing with no testing or alternative testing to evaluate fetal status in the presence of a non-reassuring cardiotocograph during labour. DATA COLLECTION AND ANALYSIS We used the standard methodological procedures of the Cochrane Pregnancy and Childbirth Group. Two review authors independently assessed the studies. MAIN RESULTS The search identified two completed randomised controlled trials (RCTs) and two ongoing trials. The two published RCTs considered outcomes for 3348 mother-baby pairs allocated to either lactate or pH estimation of fetal blood samples when clinically indicated in labour. Overall, the published RCTs were of low or unclear risk of bias. There was a high risk of performance bias, because it would not have been feasible to blind clinicians or participants.No statistically significant between-group differences were found for neonatal encephalopathy (risk ratio (RR) 1.00, 95% confidence interval (CI) 0.32 to 3.09, one study, 2992 infants) or death. No studies reported neonatal seizures. We had planned to report death with other morbidities, for example, neonatal encephalopathy; however, the data were not available in a format suitable for this, therefore death due to congenital abnormality was considered alone. The three reported neonatal deaths occurred in babies with diaphragmatic hernias (n = 2) or congenital cardiac fibrosis (n = 1). All three babies had been randomised to the pH group and were not acidaemic at birth.There were no statistically significant differences for any of the pre-specified secondary fetal/neonatal/infant outcomes for which data were available. This included low Apgar score at five minutes (RR 1.13, 95% CI 0.76 to 1.68, two studies, 3319 infants) and admission to neonatal intensive care units (RR 1.02, 95% CI 0.83 to 1.25, one study, 2992 infants), or metabolic acidaemia (RR 0.91, 95% CI 0.60 to 1.36, one study, 2675 infants) considered within the studies, either overall or where data were available for those where fetal blood sampling had occurred within 60 minutes of delivery.Similar proportions of fetuses underwent additional tests to further evaluate well-being during labour, including scalp pH if in the lactate group or scalp lactate if in the pH group (RR 0.22, 95% CI 0.04 to 1.30, two studies, 3333 infants;Tau² 1.00, I² = 58%). Fetal blood sampling attempts for lactate and pH estimation were successful in 98.7% and 79.4% of procedures respectively in the one study that reported this outcome.There were no significant between-group differences in mode of birth or operative birth for non-reassuring fetal status, either for all women, or within the group where the fetal blood sample had been taken within 60 minutes of delivery (for example, caesarean section for all enrolled, RR 1.09, 95% CI 0.97 to 1.22, two studies, 3319 women; operative delivery for non-reassuring fetal status for all enrolled RR 1.02, 95% CI 0.93 to 1.11, one study, 2992 women).Neither study reported on adverse effects of fetal scalp lacerations or maternal anxiety. AUTHORS' CONCLUSIONS When further testing to assess fetal well-being in labour is indicated, fetal scalp blood lactate estimation is more likely to be successfully undertaken than pH estimation. Further studies may consider subgroup analysis by gestational age, the stage of labour and sampling within a prolonged second stage of labour. Additionally, we await the findings from the ongoing studies that compare allocation to no fetal blood sample with sampling for lactate and address longer-term neonatal outcomes, maternal satisfaction with intrapartum fetal monitoring and an economic analysis.
Collapse
Affiliation(s)
- Christine E East
- Monash University/Monash HealthSchool of Nursing and Midwifery/Maternity Services246 Clayton RoadClaytonVictoriaAustralia3168
| | - Leo R Leader
- University of New South WalesWomen's and Children's HealthRoyal Hospital for WomenBarker StreetRandwickNSWAustralia2031
| | - Penelope Sheehan
- University of MelbourneDepartment of Obstetrics and GynaecologyPregnancy Research Centre, 7th Floor, Royal Women's Hospital20 Flemington Road, ParkvilleMelbourneVictoriaAustralia3052
| | - Naomi E Henshall
- Royal Hospital for WomenDelivery SuiteRandwickNew South WalesAustralia
| | - Paul B Colditz
- The University of Queensland, Royal Brisbane & Women's HospitalPerinatal Research CentreButterfield StreetHerstonQueenslandAustralia4029
| | - Rosalind Lau
- Monash UniversitySchool of Nursing and MidwiferyWellington RoadClaytonVictoriaAustralia3800
| | | |
Collapse
|
47
|
Prior T, Kumar S. Expert review--identification of intra-partum fetal compromise. Eur J Obstet Gynecol Reprod Biol 2015; 190:1-6. [PMID: 25917435 DOI: 10.1016/j.ejogrb.2015.04.002] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 01/31/2015] [Accepted: 04/07/2015] [Indexed: 09/30/2022]
Abstract
Whilst most cases of cerebral palsy occur as a consequence of an ante-natal insult, a significant proportion, particularly in the term fetus, are attributable to intra-partum hypoxia. Intra-partum monitoring using continuous fetal heart rate assessment has led to an increased incidence of operative delivery without a concurrent reduction in the incidence of cerebral palsy. Despite this, birth asphyxia remains the strongest and most consistent risk factor for cerebral palsy in term infants. This review evaluates current intra-partum monitoring techniques as well as alternative approaches aimed at better identification of the fetus at risk of compromise in labour.
Collapse
Affiliation(s)
- Tomas Prior
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Du Cane Road, London W12 0HS, UK; Institute for Reproductive and Developmental Biology, Imperial College London, London W12 0HS, UK
| | - Sailesh Kumar
- Centre for Fetal Care, Queen Charlotte's and Chelsea Hospital, Du Cane Road, London W12 0HS, UK; Institute for Reproductive and Developmental Biology, Imperial College London, London W12 0HS, UK; Mater Research Institute/University of Queensland, Aubigny Place, Raymond Terrace, South Brisbane, QLD 4101, Australia.
| |
Collapse
|
48
|
Umbilical cord arterial lactate compared with pH for predicting neonatal morbidity at term. Obstet Gynecol 2015; 124:756-761. [PMID: 25198278 DOI: 10.1097/aog.0000000000000466] [Citation(s) in RCA: 70] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
OBJECTIVE To test the hypothesis that umbilical cord arterial lactate is superior to pH for predicting short-term neonatal morbidity at term. METHODS We conducted a prospective cohort study of all consecutive, non-anomalous, singleton, vertex, term births from 2009 to 2012 at Washington University Medical Center. Umbilical arterial lactate and pH were measured immediately after delivery, before knowledge of neonatal outcomes. The primary outcome was a composite neonatal morbidity consisting of neonatal death, intubation, mechanical ventilation, meconium aspiration syndrome, hypoxic encephalopathy, and need for hypothermic therapy. The predictive ability of lactate and pH were compared using receiver operating characteristic curves. Optimal cutoff values of lactate and pH were estimated based on the maximal Youden index. RESULTS Of 4,997 term deliveries during the study period, 4,910 met inclusion criteria. The composite neonatal morbidity occurred in 56 neonates (1.1%). The mean lactate level was nearly twofold higher in neonates with the composite morbidity (6.49 compared with 3.26 mmol/L, P<.001), whereas mean pH values were less distinct (7.19 compared with 7.29, P<.001). Lactate was significantly more predictive of neonatal morbidity than pH (receiver operating characteristic curve area: 0.84 compared with 0.78, P=.03). The optimal cutoff value for predicting neonatal morbidity was 3.90 mmol/L for lactate and 7.25 for pH. Corresponding sensitivities and specificities were also higher for lactate (83.9% and 74.1% compared with 75.0% and 70.6%, respectively). CONCLUSION Results of this large prospective cohort study show that umbilical cord arterial lactate is a more discriminating measure of neonatal morbidity at term than pH. LEVEL OF EVIDENCE : II.
Collapse
|
49
|
Labrecque L, Provençal M, Caqueret A, Wo BL, Bujold E, Larivière F, Bédard MJ. Correlation of cord blood pH, base excess, and lactate concentration measured with a portable device for identifying fetal acidosis. JOURNAL OF OBSTETRICS AND GYNAECOLOGY CANADA 2015; 36:598-604. [PMID: 25184978 DOI: 10.1016/s1701-2163(15)30539-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
OBJECTIVE To determine the effectiveness of portable lactate analyzers in identifying fetal acidosis by correlating arterial and venous lactate values from umbilical cord blood with lactate, pH, and base excess measurements from central laboratory analyzers. METHODS We performed a prospective study using arterial and venous cord blood from 52 women with a singleton fetus delivered at term. We evaluated the correlation between the cord blood lactate concentration measured using two of the same portable devices (Lactate Plus, Nova Biomedical) with the result from a central laboratory analyzer. Analyses of the correlation between arterial lactate concentration measured on the portable device with arterial pH and base excess were then performed. RESULTS We observed a median arterial pH of 7.24 (range 7.05 to 7.35) and a median arterial lactate concentration of 3.7 mmol/L (range 1.7 to 8.8 mmol/L). An excellent correlation was observed between lactate concentrations measured by the two portable devices (arterial R² = 0.98 and venous R² = 0.98), and between the portable device and the central laboratory analyzer (arterial R² = 0.94 and venous R² = 0.95). In our population, the optimal cut-offs to predict a pH < 7.20 or a base excess > -8.0 mmol/L were a lactate concentration of 4.9 mmol/L and 5.3 mmol/L, respectively, according to receiver operator characteristic analysis. With a lactate concentration > 4.9 mmol/L, the portable device had a sensitivity of 82% and a specificity of 90% to identify samples with an arterial pH < 7.20. CONCLUSION Cord blood lactate concentration measured with a portable device is a good predictor of cord blood base excess and pH. Future studies should be designed to correlate scalp blood lactate measurements with clinical outcomes.
Collapse
Affiliation(s)
- Lyne Labrecque
- Department of Biochemistry, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Mathieu Provençal
- Department of Biochemistry, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Aurore Caqueret
- Department of Biochemistry, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Bi Lan Wo
- Department of Obstetrics and Gynecology, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Emmanuel Bujold
- Department of Obstetrics and Gynecology, Faculty of Medicine, Université Laval, Quebec QC
| | - François Larivière
- Department of Biochemistry, Centre hospitalier de l'Université de Montréal, Montreal QC
| | - Marie-Josée Bédard
- Department of Obstetrics and Gynecology, Centre hospitalier de l'Université de Montréal, Montreal QC
| |
Collapse
|
50
|
Neonatal outcome and delivery mode in labors with repetitive fetal scalp blood sampling. Eur J Obstet Gynecol Reprod Biol 2015; 184:97-102. [DOI: 10.1016/j.ejogrb.2014.11.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2014] [Revised: 10/21/2014] [Accepted: 11/11/2014] [Indexed: 10/24/2022]
|