1
|
Monaco M, Torazza C, Fedele E, Grilli M. The Impact of the Exposome on Alzheimer's Disease: The Influence of Nutrition. Int J Mol Sci 2025; 26:3015. [PMID: 40243652 PMCID: PMC11988514 DOI: 10.3390/ijms26073015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2025] [Revised: 03/18/2025] [Accepted: 03/24/2025] [Indexed: 04/18/2025] Open
Abstract
Alzheimer's disease (AD) is a progressive neurodegenerative disease characterized by cognitive decline, memory loss, and behavioural changes. While genetic predispositions and pathological processes have been the traditional focus, this review highlights the fundamental role of environmental factors, particularly nutrition, within the exposome framework in modulating the risk and progression of AD. The exposome, which includes the totality of environmental exposures in an individual's lifetime, provides a comprehensive approach to understanding the complex aetiology of AD. In this review, we explore the impact of dietary factors and cyclic nucleotide pathways (cAMP/cGMP) on AD, emphasizing the potential of dietary interventions as therapeutic strategies. We investigate key aspects of how nutrition affects the accumulation of β-amyloid, the aggregation of tau proteins, and neuroinflammation. We also examine the impact of specific nutrients on cognitive performance and the risk of AD. Additionally, we discuss the potential of nutraceuticals with anti-phosphodiesterase activity and the role of various animal models of AD (such as 5xFAD, 3xTg-AD, Tg2576, and APP/PS1 mice) in demonstrating the effects of dietary interventions on disease onset and progression.
Collapse
Affiliation(s)
- Martina Monaco
- Pharmacology and Toxicology Unit, Department of Pharmacy, School of Medical and Pharmaceutical Sciences, University of Genoa, Viale Cembrano 4, 16148 Genoa, Italy; (M.M.); (C.T.); (E.F.)
| | - Carola Torazza
- Pharmacology and Toxicology Unit, Department of Pharmacy, School of Medical and Pharmaceutical Sciences, University of Genoa, Viale Cembrano 4, 16148 Genoa, Italy; (M.M.); (C.T.); (E.F.)
| | - Ernesto Fedele
- Pharmacology and Toxicology Unit, Department of Pharmacy, School of Medical and Pharmaceutical Sciences, University of Genoa, Viale Cembrano 4, 16148 Genoa, Italy; (M.M.); (C.T.); (E.F.)
- IRCCS Ospedale Policlinico San Martino, 16132 Genoa, Italy
| | - Massimo Grilli
- Pharmacology and Toxicology Unit, Department of Pharmacy, School of Medical and Pharmaceutical Sciences, University of Genoa, Viale Cembrano 4, 16148 Genoa, Italy; (M.M.); (C.T.); (E.F.)
- IRCCS Ospedale Policlinico San Martino, 16132 Genoa, Italy
| |
Collapse
|
2
|
Kawamura K, Fukusaki E. Novel sampling and gas-phase derivatization strategy: Proof-of-concept by profiling ionic polar metabolites using gas chromatography-mass spectrometry. J Biosci Bioeng 2024; 138:462-468. [PMID: 39232914 DOI: 10.1016/j.jbiosc.2024.07.019] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 07/12/2024] [Accepted: 07/30/2024] [Indexed: 09/06/2024]
Abstract
Metabolomic research involves the comprehensive analysis of metabolites in biological samples and has many applications. Gas chromatography-mass spectrometry (GC-MS) is an established and widely used approach for metabolic profiling. However, sample preparation and metabolite derivatization are time-consuming, and derivatization options are limited. We propose gas-solid phase derivatization (GSPD) as a novel sampling and derivatization method that uses a silica monolith substrate and gaseous derivatization reagents for metabolomics using GC-MS. We developed a method to measure the organic acids and sugar phosphates responsible for glycolysis and the tricarboxylic acid (TCA) cycle. GSPD simplifies the sample preparation and can be applied to derivatization reactions that are difficult to perform in solution owing to solvent limitations. The developed method was applied to human plasma and tomato pulp and was shown to have a higher detection performance than the conventional method. This study provides a strategy to simplify sample preparation and expand derivatization options for GC-MS-based metabolomics.
Collapse
Affiliation(s)
- Kazuhiro Kawamura
- Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan; Life Science Business Department, Shimadzu Corporation, 1 Nishinokyo Kuwabara-cho, Nakagyo-ku, Kyoto 604-8511, Japan; Osaka University Shimadzu Analytical Innovation Research Laboratory, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan
| | - Eiichiro Fukusaki
- Department of Biotechnology, Graduate School of Engineering, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan; Osaka University Shimadzu Analytical Innovation Research Laboratory, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan; Institute for Open and Transdisciplinary Research Initiatives, Osaka University, 2-1 Yamadaoka, Suita, Osaka 565-0871, Japan.
| |
Collapse
|
3
|
Dugheri S, Mucci N, Cappelli G, Bonari A, Campagna M, Arcangeli G, Bartolucci G. New fully automated gas chromatographic analysis of urinary S-phenylmercapturic acid in isotopic dilution using negative chemical ionization with isobutane as reagent gas. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4481. [PMID: 31770470 DOI: 10.1002/jms.4481] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2019] [Revised: 11/19/2019] [Accepted: 11/22/2019] [Indexed: 06/10/2023]
Abstract
The determination of urinary S-phenylmercapturic acid (S-PMA) represents the most reliable biomarker to monitor the intake risk of airborne benzene. Recently, the European Chemical Agency deliberated new occupational exposure limits for benzene and recommended an S-PMA biological limit value of 2-μg/g creatinine. This limit is an order of magnitude lower than the previous one, and its determination constitutes a challenge in the analytical field. We developed and validated a method that allows the fully automated and sensitive determination of S-PMA by the use of gas-chromatography negative chemical ionization tandem mass spectrometry in isotopic dilution. For negative chemical ionization, we selected a mixture of 1% isobutane in argon as reactive gas, by studying its chemical ionization mechanism and optimal parameters compared with pure isobutane or pure methane. This gas mixture produces a more abundant signal of the target analyte than isobutane or methane, and it extended the operative lifetime of the ion source, enabling us to start a high-throughput approach of the S-PMA analysis. Moreover, energy-resolved mass spectrometry experiments were carried out to refine the MS/MS analysis conditions, testing nitrogen and argon as collision gases. The method optimization was pursued by a chemometric model by using the experimental design. The quantification limit for S-PMA was 0.10 μg/L. Accuracy (between 98.3% and 99.6%) and precision (ranging from 1.6% to 6.4%) were also evaluated. In conclusion, the newly developed assay represents a powerful tool for the robust, reliable, and sensitive quantification of urinary S-PMA, and because of its automation, it is well suited for application in large environmental and biological monitoring.
Collapse
Affiliation(s)
- Stefano Dugheri
- Industrial Hygiene and Toxicology Laboratory, Occupational Medicine Unit, Careggi University Hospital, Florence, Italy
| | - Nicola Mucci
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Giovanni Cappelli
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | | | - Marcello Campagna
- Department of Medical Science and Public Health, University of Cagliari, Monserrato, Italy
| | - Giulio Arcangeli
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Gianluca Bartolucci
- Department of Neurosciences, Psychology, Drug Research and Child Health, University of Florence, Sesto Fiorentino, Italy
| |
Collapse
|
4
|
Dugheri S, Mucci N, Bonari A, Marrubini G, Cappelli G, Ubiali D, Campagna M, Montalti M, Arcangeli G. Liquid phase microextraction techniques combined with chromatography analysis: a review. ACTA CHROMATOGR 2020. [DOI: 10.1556/1326.2019.00636] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Sample pretreatment is the first and the most important step of an analytical procedure. In routine analysis, liquid–liquid microextraction (LLE) is the most widely used sample pre-treatment technique, whose goal is to isolate the target analytes, provide enrichment, with cleanup to lower the chemical noise, and enhance the signal. The use of extensive volumes of hazardous organic solvents and production of large amounts of waste make LLE procedures unsuitable for modern, highly automated laboratories, expensive, and environmentally unfriendly. In the past two decades, liquid-phase microextraction (LPME) was introduced to overcome these drawbacks. Thanks to the need of only a few microliters of extraction solvent, LPME techniques have been widely adopted by the scientific community. The aim of this review is to report on the state-of-the-art LPME techniques used in gas and liquid chromatography. Attention was paid to the classification of the LPME operating modes, to the historical contextualization of LPME applications, and to the advantages of microextraction in methods respecting the value of green analytical chemistry. Technical aspects such as description of methodology selected in method development for routine use, specific variants of LPME developed for complex matrices, derivatization, and enrichment techniques are also discussed.
Collapse
Affiliation(s)
- Stefano Dugheri
- 1 Industrial Hygiene and Toxicology Laboratory, Careggi University Hospital, Florence, Italy
| | - Nicola Mucci
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Alessandro Bonari
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | | | - Giovanni Cappelli
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Daniela Ubiali
- 3 Department of Drug Sciences, University of Pavia, Pavia, Italy
| | - Marcello Campagna
- 4 Department of Medical Sciences and Public Health, University of Cagliari, Cagliari, Italy
| | - Manfredi Montalti
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Giulio Arcangeli
- 2 Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| |
Collapse
|
5
|
Pagliano E. Versatile derivatization for GC-MS and LC-MS: alkylation with trialkyloxonium tetrafluoroborates for inorganic anions, chemical warfare agent degradation products, organic acids, and proteomic analysis. Anal Bioanal Chem 2020; 412:1963-1971. [PMID: 31915869 DOI: 10.1007/s00216-019-02299-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Revised: 11/04/2019] [Accepted: 11/21/2019] [Indexed: 10/25/2022]
Abstract
Analytical chemists resort to derivatization for improving the detection performance of certain categories of analytes. Within this context, alkylation reactions are regarded as an important asset for many methods based on GC-MS and LC-MS. Trialkyloxonium tetrafluoroborates (R[Formula: see text][BF4]-) are powerful alkylating agents with ionic liquid properties: they are nonvolatile salts soluble in water which are easier and safer to handle with respect to common alkylating agents like diazomethane. R[Formula: see text][BF4]- can perform the alkylation in both organic and aqueous media at pH conditions ranging from acidic to alkaline. Recent analytical applications of trialkyloxonium derivatizations include the high-precision determination of inorganic anions in complex matrices, the qualitative confirmation of chemical warfare agent degradation products in soils, the profiling of carboxylic acids in urine, and the detection of protein post-translational modifications induced by carbon dioxide. The common denominator for all methods presented can be found in the simplicity of the alkylation protocol which, in most of the cases, requires a single step addition of the reagent directly to the sample. Graphical Abstract Alkylation with trialkyloxonium salts for GC-MS and LC-MS analysis.
Collapse
Affiliation(s)
- Enea Pagliano
- National Research Council Canada, 1200 Montreal Road, K1A 0R6, Ottawa, Ontario, Canada.
| |
Collapse
|
6
|
Christou C, Gika HG, Raikos N, Theodoridis G. GC-MS analysis of organic acids in human urine in clinical settings: A study of derivatization and other analytical parameters. J Chromatogr B Analyt Technol Biomed Life Sci 2014; 964:195-201. [DOI: 10.1016/j.jchromb.2013.12.038] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2013] [Revised: 12/28/2013] [Accepted: 12/31/2013] [Indexed: 11/16/2022]
|
7
|
Chalabiani A, Abbas Matin A, Farhadi K. Zeolite-SiC in PVC Matrix as a New SPME Fiber for Gas Chromatographic Determination of BTEX in Water and Soil Samples. J CHIN CHEM SOC-TAIP 2012. [DOI: 10.1002/jccs.201100692] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
8
|
Kauna-Czaplińska J. Current Applications of Gas Chromatography/Mass Spectrometry in the Study of Organic Acids in Urine. Crit Rev Anal Chem 2011. [DOI: 10.1080/10408347.2011.555242] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
9
|
Baxter JH, Phillips RR, Dowlati L, Goehring KC, Johns PW. Direct Determination of β-Hydroxy-β-Methylbutyrate (HMB) in Liquid Nutritional Products. FOOD ANAL METHOD 2010. [DOI: 10.1007/s12161-010-9173-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
10
|
Pacenti M, Dugheri S, Traldi P, Degli Esposti F, Perchiazzi N, Franchi E, Calamante M, Kikic I, Alessi P, Bonacchi A, Salvadori E, Arcangeli G, Cupelli V. New automated and high-throughput quantitative analysis of urinary ketones by multifiber exchange-solid phase microextraction coupled to fast gas chromatography/negative chemical-electron ionization/mass spectrometry. JOURNAL OF AUTOMATED METHODS & MANAGEMENT IN CHEMISTRY 2010; 2010:972926. [PMID: 20628512 PMCID: PMC2902044 DOI: 10.1155/2010/972926] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/16/2009] [Accepted: 04/12/2010] [Indexed: 05/29/2023]
Abstract
The present research is focused on automation, miniaturization, and system interaction with high throughput for multiple and specific Direct Immersion-Solid Phase Microextraction/Fast Gas Chromatography analysis of the urinary ketones. The specific Mass Spectrometry instrumentation, capable of supporting such the automated changeover from Negative Chemical to Electron Ionization mode, as well as the automation of the preparation procedure by new device called MultiFiber Exchange, through change of the fibers, allowed a friendly use of mass spectrometry apparatus with a number of advantages including reduced analyst time and greater reproducibility (2.01-5.32%). The detection limits for the seven ketones were less than 0.004 mg/L. For an innovative powerful meaning in high-throughput routine, the generality of the structurally informative Mass Spectrometry fragmentation patterns together with the chromatographic separation and software automation are also investigated.
Collapse
Affiliation(s)
- Marco Pacenti
- Occupational Health Division, Department of Public Health, Viale Morgagni 48, University of Florence, 50100 Florence, Italy
| | - Stefano Dugheri
- Occupational Health Division, Department of Public Health, Viale Morgagni 48, University of Florence, 50100 Florence, Italy
| | - Pietro Traldi
- CNR-Istitute of Molecular Science and Technologies, Corso Stati Uniti 4, 35100 Padova, Italy
| | | | | | - Elena Franchi
- Organic Chemistry Department/ProtEra Srl (Spin Off of Magnetic Resonance Center), Via Lastruccia 13, University of Florence, Sesto Fiorentino, 50019 Florence, Italy
| | - Massimo Calamante
- Organic Chemistry Department/ProtEra Srl (Spin Off of Magnetic Resonance Center), Via Lastruccia 13, University of Florence, Sesto Fiorentino, 50019 Florence, Italy
| | - Ireneo Kikic
- Department of Chemical, Environmental and Raw Materials Engineering (DICAMP), Piazzale Europa 1, University of Trieste, 34127 Trieste, Italy
| | - Paolo Alessi
- Department of Chemical, Environmental and Raw Materials Engineering (DICAMP), Piazzale Europa 1, University of Trieste, 34127 Trieste, Italy
| | - Alice Bonacchi
- Occupational Health Division, Department of Public Health, Viale Morgagni 48, University of Florence, 50100 Florence, Italy
| | - Edoardo Salvadori
- Occupational Health Division, Department of Public Health, Viale Morgagni 48, University of Florence, 50100 Florence, Italy
| | - Giulio Arcangeli
- Occupational Health Division, Department of Public Health, Viale Morgagni 48, University of Florence, 50100 Florence, Italy
| | - Vincenzo Cupelli
- Occupational Health Division, Department of Public Health, Viale Morgagni 48, University of Florence, 50100 Florence, Italy
| |
Collapse
|
11
|
Pacenti M, Dugheri S, Villanelli F, Bartolucci G, Calamai L, Boccalon P, Arcangeli G, Vecchione F, Alessi P, Kikic I, Cupelli V. Determination of organic acids in urine by solid-phase microextraction and gas chromatography-ion trap tandem mass spectrometry previous ‘in sample’ derivatization with trimethyloxonium tetrafluoroborate. Biomed Chromatogr 2008; 22:1155-63. [DOI: 10.1002/bmc.1039] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
12
|
Farajzadeh MA, Matin AA. Determination of BTEX in Water Samples with an SPME Hollow Fiber Coated Copper Wire. Chromatographia 2008. [DOI: 10.1365/s10337-008-0726-z] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
13
|
Law WS, Zhao JH, Hauser PC, Yau Li SF. Capillary electrophoresis with capacitively coupled contactless conductivity detection for low molecular weight organic acids in different samples. J Sep Sci 2007; 30:3247-54. [DOI: 10.1002/jssc.200700306] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
14
|
Li N, Deng C, Zhang X. Determination of methylmalonic acid and glutaric acid in urine by aqueous-phase derivatization followed by headspace solid-phase microextraction and gas chromatography-mass spectrometry. J Sep Sci 2007; 30:266-71. [PMID: 17390622 DOI: 10.1002/jssc.200600296] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
In this work, a novel technique of aqueous-phase derivatization followed by headspace solid-phase microextraction and gas chromatography-mass spectrometry was developed for the determination of organic acids in urine. The analytical procedure involves derivatization of organic acids to their ethyl esters with diethyl sulfate, headspace sampling, and GC/MS analysis. The proposed method was applied to the determination of methylmalonic acid and glutaric acid in urine. The experimental parameters and method validation were studied. Optimal conditions were obtained: PDMS fiber, extraction temperature 55 degrees C, extraction time 30 min, and 60 microL of diethyl sulfate as derivatization reagent with 2 mg of the ion pairing agent tetrabutylammonium hydrogensulfate. The method was linear over three orders of magnitude, and detection limits were 21 nM for methylmalonic acid and 34 nM for glutaric acid, respectively. Consequently, in-situ derivatization/HS-SPME/GC/MS is an alternative and powerful method for determination of organic acids as biomarkers in biological fluids.
Collapse
Affiliation(s)
- Ning Li
- Department of Chemistry, Fudan University, Shanghai, PR China
| | | | | |
Collapse
|
15
|
Pardasani D, Palit M, Gupta AK, Kanaujia PK, Sekhar K, Dubey DK. Microemulsion mediated in situ derivatization–extraction and gas chromatography–mass spectrometric analysis of alkylphosphonic acids. J Chromatogr A 2006; 1108:166-75. [PMID: 16455095 DOI: 10.1016/j.chroma.2006.01.044] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2005] [Revised: 12/27/2005] [Accepted: 01/03/2006] [Indexed: 11/28/2022]
Abstract
Detection and identification of environmental signatures of chemical warfare agents is an important aspect of verification program of Chemical Weapons Convention (CWC). Alkylphosphonic acids (APAs) are ultimate and persistent degradation products of nerve agents. Their identification in a sample submitted for off-site analysis infers possible indication of contamination with nerve agents. This paper describes the development of a new sample preparation method which involves 'in situ derivatization and extraction' (INDEX) of acids from water. Derivatization is performed by alkylation of APAs with alkylbromides in surfactant less microemulsion (SLME). The derivatized analytes were analyzed by gas chromatography coupled with mass spectrometry. The developed method involves simultaneous derivatization (alkylation) and extraction of acidic analytes mediated by surfactant less microemulsion. Various derivatization-extraction parameters such as solvent, reaction time and temperature, base and alkyl bromides were optimized. Pentyl bromide in the presence of potassium carbonate and diisopropylamine at 100 degrees C derivatized the selected acids efficiently. Kinetic data for alkylation of methylphosphonic acids and some carboxylic acids were obtained to assess their relative susceptibility for alkylation in microemulsion. Methylphosphonic acid and isopropyl methylphosphonic acid took 140-150 min to reach completion while carboxylic acids took 100 min to complete the reaction. INDEX could be successfully performed even in the presence of interfering Ca(2+) and Mg(2+) ions.
Collapse
Affiliation(s)
- Deepak Pardasani
- Vertox Laboratory, Defence Research & Development Establishment, Jhansi Road, Gwalior 474002, India
| | | | | | | | | | | |
Collapse
|
16
|
Iadarola P, Cetta G, Luisetti M, Annovazzi L, Casado B, Baraniuk J, Zanone C, Viglio S. Micellar electrokinetic chromatographic and capillary zone electrophoretic methods for screening urinary biomarkers of human disorders: a critical review of the state-of-the-art. Electrophoresis 2005; 26:752-766. [PMID: 15669008 DOI: 10.1002/elps.200410195] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Human urine plays a central role in clinical diagnostic being one of the most-frequently used body fluid for detection of biological markers. Samples from patients with different diseases display patterns of biomarkers that differ significantly from those obtained from healthy subjects. The availability of fast, reproducible, and easy-to-apply analytical techniques that would allow identification of a large number of these analytes is thus highly desiderable since they may provide detailed information about the progression of a pathological process. From among the variety of methods so far applied for the determination of urinary metabolites, capillary electrophoresis, both in the capillary zone electrophoresis (CZE) and micellar electrokinetic chromatography (MEKC) modes, represents a robust and reliable analytical tool widely used in this area. The aim of the present article is to focus the interest of the reader on recent applications of MEKC and CZE in the field of urinary biomarkers and to discuss advantages and/or limitations of each mode.
Collapse
Affiliation(s)
- Paolo Iadarola
- Dipartimento di Biochimica A.Castellani, Università di Pavia, Pavia, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Guillo C, Barlow D, Perrett D, Hanna-Brown M. Micellar electrokinetic capillary chromatography and data alignment analysis: a new tool in urine profiling. J Chromatogr A 2004; 1027:203-12. [PMID: 14971504 DOI: 10.1016/j.chroma.2003.11.102] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
The complex nature of biofluids demands efficient, sensitive and high-resolution analytical methodologies to examine how the 'metabolic fingerprint' changes during disease. This paper describes how sulphated beta-cyclodextrin-modified micellar electrokinetic capillary chromatography (SbetaCD-MECC) has been combined with data alignment analysis and may prove a useful new tool in urine profiling, allowing for separation of over 80 urinary analytes in under 25 min. The optimised and validated SbetaCD-MECC methodology combined with data alignment analysis provides rapid identification of 'mismatches' between urine profiles which are not easily detected with the naked eye as well as a 'similarity score' which indicates the total sum of differences between one profile and another. The combination of SbetaCD-MECC with data alignment software should prove a useful alternative tool in metabonomic studies for rapid comparison of urine profiles.
Collapse
|
18
|
Development of fatty acid analysis by high-performance liquid chromatography, gas chromatography, and related techniques. Anal Chim Acta 2002. [DOI: 10.1016/s0003-2670(01)01467-2] [Citation(s) in RCA: 109] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
19
|
Affiliation(s)
- D H Chace
- Division of Bio-Analytical Chemistry and Mass Spectrometry, Neo Gen Screening, Inc., P.O. Box 219, Bridgeville, Pennsylvania 15017, USA.
| |
Collapse
|