1
|
Meyer S, Clases D, Gonzalez de Vega R, Padula MP, Doble PA. Separation of intact proteins by capillary electrophoresis. Analyst 2022; 147:2988-2996. [PMID: 35673805 DOI: 10.1039/d2an00474g] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
This work introduces novel and universal workflows for the analysis of intact proteins by capillary electrophoresis and presents guidelines for the targeted selection of appropriate background electrolytes (BGEs) by consideration of the target proteins' isoelectric point (pI). The suitability of neutral dimethyl polysiloxane (PDMS) capillaries with dynamic coatings of cationic cetyltrimethylammonium bromide (CTAB) or anionic sodium dodecyl sulfate (SDS), and bare fused silica (BFS) capillaries were systematically evaluated for the analysis of histidine and seven model proteins in six BGEs with pH values between 3.0 and 9.6. Multiple capillary and BGE combinations were suitable for the analysis of all proteins with molecular weights ranging from 13.7-150 kDa, and pIs between 4.7 and 9.6. The CTAB-PDMS capillary was best suited for low pH BGEs, while the SDS-PDMS and BFS capillary were superior for high pH BGEs. These combinations consistently resulted in sharp peak shapes and rapid migration times. pH values of BGEs closer to the proteins' pI produced poorer peak shapes and decreased effective mobilities due to suppressed ionisation. Plots of mobility vs. pH crossed at approximately the pI of the protein in most cases. The workflow was applied to the analysis of caseins and whey proteins in milk for the separation of the seven most abundant proteins, including the isoforms of A1 and A2 β-casein and β-lactoglobulin A and B.
Collapse
Affiliation(s)
- Sarah Meyer
- The Atomic Medicine Initiative, University of Technology Sydney, Sydney, NSW, Australia.
| | - David Clases
- Institute of Chemistry, University of Graz, Graz, Austria
| | | | - Matthew P Padula
- School of Life Sciences and Proteomics, Lipidomics and Metabolomics Core Facility, Faculty of Science, University of Technology Sydney, Sydney, NSW, Australia
| | - Philip A Doble
- The Atomic Medicine Initiative, University of Technology Sydney, Sydney, NSW, Australia.
| |
Collapse
|
2
|
Zhang C, Schumacher KN, Dodds ED, Hage DS. Glycoprotein analysis using lectin microcolumns and capillary electrophoresis: Characterization of alpha 1-acid glycoprotein by combined separation methods. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1179:122855. [PMID: 34274643 DOI: 10.1016/j.jchromb.2021.122855] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2020] [Revised: 07/02/2021] [Accepted: 07/05/2021] [Indexed: 11/17/2022]
Abstract
Separations based on combinations of 2.1 mm I.D. high-performance affinity microcolumns and capillary electrophoresis were developed and used to characterize the glycoforms of an intact glycoprotein. Human alpha1-acid glycoprotein (AGP) was used as a model analyte due to its heterogeneous glycosylation resulting from variations in its degree of branching, fucosylation, and number of sialic acids. Three separation formats were examined based on microcolumns that contained the lectins concanavalin A (Con A) or Aleuria aurantia lectin (AAL). These microcolumns were used with one another or in combination with capillary electrophoresis. N-Glycan analysis of the non-retained and retained AGP fractions was carried out by using PNGase F digestion and nanoflow electrospray ionization mass spectrometry. Con A microcolumns were found to selectively enrich AGP that contained bi-antennary N-glycans, while AAL microcolumns retained AGP with fucose-containing N-glycans. Results from these separation methods indicated that fucosylation of the N-linked glycans was more abundant when a high degree of branching was present in AGP. Sialic acid residues were more abundant when higher degrees of branching and more fucose residues were present in AGP. The separation and analysis methods that were developed could be used with relatively small amounts of AGP and can be adapted for use with other intact glycoproteins.
Collapse
Affiliation(s)
- Chenhua Zhang
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | | | - Eric D Dodds
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
3
|
Gao T, Li X, Jia Z, Hendrickx F, Falmagne JB, Chen HX. Rapid Capillary Zone Electrophoresis of Recombinant Erythropoietin by the Use of Dynamic Double Layer Coating. ANAL LETT 2020. [DOI: 10.1080/00032719.2020.1750023] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Affiliation(s)
| | - Xiang Li
- National Institute of Food and Drug Control, Beijing, China
| | - Zeng Jia
- Beijing BioCEart Technology Institute, Beijing, China
| | | | | | | |
Collapse
|
4
|
Zhang C, Bi C, Clarke W, Hage DS. Glycoform analysis of alpha 1-acid glycoprotein based on capillary electrophoresis and electrophoretic injection. J Chromatogr A 2017; 1523:114-122. [PMID: 28844299 DOI: 10.1016/j.chroma.2017.08.032] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2017] [Revised: 08/10/2017] [Accepted: 08/10/2017] [Indexed: 01/18/2023]
Abstract
A method based on capillary electrophoresis (CE) with electrophoretic injection and absorbance detection was developed for the direct analysis of AGP glycoforms in human serum. Electrophoretic injection of AGP was performed in the reversed-polarity mode of CE with a capillary coated with poly(ethylene oxide) and that had minimal electroosmotic flow. This situation created an essentially stationary interface between the sample and running buffer during injection and sample stacking. This approach allowed an 11,000-fold increase in sample loading for a 5min injection versus hydrodynamic injection and without introducing any significant levels of extra band-broadening. This method was used with sample pretreatment methods based on acid precipitation and desalting to examine AGP glycoforms in only 65μL of serum. A limit of detection of 2.1-11.3nM was obtained for the major AGP glycoform bands in serum, and the sample pretreatment method gave a recovery of 72.3-80.9% for these glycoforms. The precision for the migration times was ±0.08-0.13% and the precision for the peak areas was ±0.34-1.18% when using serum samples and an internal standard. This method was used for both normal pooled serum and serum from individuals with systemic lupus erythematosus. Results were obtained in a separation time of 25min and allowed the comparison of up to eleven glycoform bands in these samples. A similar approach may be useful in examining additional glycoproteins in serum or other types of biological samples.
Collapse
Affiliation(s)
- Chenhua Zhang
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - Cong Bi
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - William Clarke
- Department of Pathology, Johns Hopkins University School of Medicine, Baltimore, MD 21287, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
5
|
Van Rompuy LS, Parac-Vogt TN. Polyoxometalates as sialidase mimics: selective and non-destructive removal of sialic acid from a glycoprotein promoted by phosphotungstic acid. Chem Commun (Camb) 2017; 53:10600-10603. [DOI: 10.1039/c7cc05888h] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
The selective hydrolysis of the glycosidic bond between the terminal sialic acid and the penultimate sugar has been achieved in the alpha-2-HS-glycoprotein (Fetuin-A) in the presence of H3PW12O40, a Keggin type polyoxometalate.
Collapse
|
6
|
Zhang C, Hage DS. Glycoform analysis of alpha 1-acid glycoprotein by capillary electrophoresis. J Chromatogr A 2016; 1475:102-109. [PMID: 27863712 PMCID: PMC5147584 DOI: 10.1016/j.chroma.2016.11.014] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2016] [Revised: 11/09/2016] [Accepted: 11/10/2016] [Indexed: 11/25/2022]
Abstract
A relatively fast and reproducible CE separation was developed for the glycoform analysis of α1-acid glycoprotein (AGP). Factors that were considered included the pH for this separation and various techniques for coating the capillary and/or to minimize electroosmotic flow and protein adsorption. Optimum resolution of the AGP glycoforms was obtained at pH 4.2 with a running buffer containing 0.1% Brij 35 and by using static and dynamic coatings of PEO on the capillary. These conditions made it possible to separate nine AGP glycoform bands in about 20min. The limit of detection (based on absorbance measurements) ranged from 0.09 to 0.38μM for these AGP glycoform bands, and the linear range extended up to a total AGP concentration of at least 240μM. The migration times for the glycoform bands had typical within-day and day-to-day precisions of ±0.16-0.23% or less, respectively, on a single treated capillary and the variation between capillaries was ±0.56% or less. A charge ladder approach was employed to examine the mass or charge differences in the glycoforms that made up these bands, giving a good fit to a model in which the neighboring bands differed by one charge (e.g., from a sialic acid residue) and had an average mass difference of approximately 0.7-0.9kDa. The approaches used to develop this separation method are not limited to AGP but could be extended to the analysis of other glycoproteins by CE.
Collapse
Affiliation(s)
- Chenhua Zhang
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA
| | - David S Hage
- Department of Chemistry, University of Nebraska, Lincoln, NE 68588, USA.
| |
Collapse
|
7
|
Zhang L, Lawson K, Yeung B, Wypych J. Capillary Zone Electrophoresis Method for a Highly Glycosylated and Sialylated Recombinant Protein: Development, Characterization and Application for Process Development. Anal Chem 2014; 87:470-6. [DOI: 10.1021/ac504187v] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Le Zhang
- Analytical
Sciences of Drug Substance Department, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Ken Lawson
- Analytical
Sciences of Drug Substance Department, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Bernice Yeung
- Analytical
Sciences of Drug Substance Department, Amgen, Inc., Thousand Oaks, California 91320, United States
| | - Jette Wypych
- Analytical
Sciences of Drug Substance Department, Amgen, Inc., Thousand Oaks, California 91320, United States
| |
Collapse
|
8
|
Palmisano G, Larsen MR, Packer NH, Thaysen-Andersen M. Structural analysis of glycoprotein sialylation – part II: LC-MS based detection. RSC Adv 2013. [DOI: 10.1039/c3ra42969e] [Citation(s) in RCA: 69] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/03/2023] Open
|
9
|
Garrido-Medina R, Díez-Masa JC, de Frutos M. CE methods for analysis of isoforms of prostate-specific antigen compatible with online derivatization for LIF detection. Electrophoresis 2011; 32:2036-43. [DOI: 10.1002/elps.201000524] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2010] [Revised: 01/28/2011] [Accepted: 01/29/2011] [Indexed: 11/08/2022]
|
10
|
Recent advances in the analysis of carbohydrates for biomedical use. J Pharm Biomed Anal 2011; 55:702-27. [DOI: 10.1016/j.jpba.2011.02.003] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2010] [Revised: 02/03/2011] [Accepted: 02/04/2011] [Indexed: 02/06/2023]
|
11
|
Protein glycosylation analysis with capillary-based electromigrative separation techniques. ACTA ACUST UNITED AC 2010. [DOI: 10.1007/s12566-010-0018-6] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
12
|
Maeda E, Urakami K, Shimura K, Kinoshita M, Kakehi K. Charge heterogeneity of a therapeutic monoclonal antibody conjugated with a cytotoxic antitumor antibiotic, calicheamicin. J Chromatogr A 2010; 1217:7164-71. [PMID: 20932526 DOI: 10.1016/j.chroma.2010.09.022] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2010] [Revised: 09/01/2010] [Accepted: 09/08/2010] [Indexed: 12/28/2022]
Abstract
A robust and highly reproducible capillary isoelectric focusing (cIEF) method for the evaluation of charge heterogeneity of monoclonal antibody (mAb) pharmaceutical which contains covalently bound antitumor compounds was developed using a combination of commercially available dimethylpolysiloxane-coated capillary and carrier ampholyte. In order to optimize major analytical parameters for robust mobilization, experimental responses from three pI markers were selected. The optimized method gave excellent repeatability and intermediate precision in estimated pI values of charge variants with relative standard deviations (RSDs) of not more than 0.06% and 0.95%, respectively, when using IgG(4) as a model. Furthermore, RSDs of charge variant compositions were less than 5.0%. These results suggest that the proposed method can be a powerful tool for reproducible evaluation of charge variants of both naked mAbs and their conjugates with high resolution, and it is applicable to quality testing and detailed characterization in the pharmaceutical industry. In addition, it should be noticed that the method provided non-linear pH gradient within the tested ranges, from pI 9.50 to 3.78, and the pH gradient caused the inconsistency of estimated pI ranges between cIEF and gel IEF. This result indicates that selecting appropriate pI markers based on the target pI ranges of charge variants for each mAb related pharmaceutical is highly recommended for the precise determination of pI values.
Collapse
Affiliation(s)
- Eiki Maeda
- Analytical Development Laboratories, CMC Center, Takeda Pharmaceutical Company Limited, Juso-honmachi 2-17-85, Yodogawa-ku, Osaka 532-8686, Japan. maeda
| | | | | | | | | |
Collapse
|
13
|
Optimization and qualification of capillary zone electrophoresis method for glycoprotein isoform distribution of erythropoietin for quality control laboratory. J Pharm Biomed Anal 2009; 50:538-43. [DOI: 10.1016/j.jpba.2009.05.007] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2009] [Revised: 05/08/2009] [Accepted: 05/08/2009] [Indexed: 11/21/2022]
|
14
|
Németh K, Kremmer T, Kocsis L, Visy J. Glycoform Heterogeneity of Human Serum α1-Acid Glycoprotein Determined by CZE in Malignant Diseases. Chromatographia 2009. [DOI: 10.1365/s10337-009-1046-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
15
|
Nakano M, Higo D, Arai E, Nakagawa T, Kakehi K, Taniguchi N, Kondo A. Capillary electrophoresis-electrospray ionization mass spectrometry for rapid and sensitive N-glycan analysis of glycoproteins as 9-fluorenylmethyl derivatives. Glycobiology 2008; 19:135-43. [PMID: 18955373 DOI: 10.1093/glycob/cwn115] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
It is well known that most protein therapeutics such as monoclonal antibody pharmaceuticals and other biopharmaceuticals including cancer biomarkers are glycoproteins, and thus the development of high-throughput and sensitive analytical methods for glycans is essential in terms of their determination and quality control. We previously reported a novel alternative labeling method for glycans involving 9-fluorenylmethyl chloroformate (Fmoc-Cl) instead of the conventional reductive amination procedure. The derivatives were analyzed by high-performance liquid chromatography (HPLC) (Kamoda S, Nakano M, Ishikawa R, Suzuki S, Kakehi K. 2005. Rapid and sensitive screening of N-glycans as 9-fluorenylmethyl derivatives by high-performance liquid chromatography: A method which can recover free oligosaccharides after analysis. J Proteome Res. 4:146-152). This method was rapid and simple; however, it was time-consuming in terms of analysis by HPLC and did not provide so much information such as the detailed structures and mass numbers of glycans. Here we have developed a high-throughput and highly sensitive method. It comprises three steps, i.e., release of glycans, derivatization with Fmoc, and capillary electrophoresis-electrospray ionization mass spectrometry (CE-ESI MS) analysis. We analyzed several glycoproteins such as fetuin, alpha1 acid glycoprotein, IgG, and transferrin in order to validate this method. We were able to analyze the above glycoproteins with the three-step procedure within only 5 h, which provided detailed N-glycan patterns. Moreover, the MS/MS analysis allowed identification of the N-glycan structures. As novel applications, the method was employed for the analysis of N-glycans derived from monoclonal antibody pharmaceuticals and also from alpha-fetoprotein; the latter is known as one of the tumor markers of hepatocellular carcinomas. We were able to easily and rapidly determine the detailed structures of the N-glycans. The present method is very useful for the analysis of large numbers of samples such as a routine analysis.
Collapse
Affiliation(s)
- Miyako Nakano
- Department of Chemistry and Biomolecular Science, Macquarie University, Sydney NSW 2109, Australia
| | | | | | | | | | | | | |
Collapse
|
16
|
Miyado T, Wakida SI, Aizawa H, Shibutani Y, Kanie T, Katayama M, Nose K, Shimouchi A. High-throughput assay of nitric oxide metabolites in human plasma without deproteinization by lab-on-a-chip electrophoresis using a zwitterionic additive. J Chromatogr A 2008; 1206:41-4. [PMID: 18692851 DOI: 10.1016/j.chroma.2008.07.065] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2008] [Revised: 07/18/2008] [Accepted: 07/22/2008] [Indexed: 01/08/2023]
Abstract
In order to develop a high-throughput assay for nitric oxide metabolites, nitrite (NO2-) and nitrate (NO3-), in biological fluids, we have investigated the simultaneous determination of them using an electrophoretic lab-on-a-chip (microchip capillary electrophoresis, MCE) technique. In this study, in order to establish an MCE assay process without deproteinization, the addition of a zwitterionic additive into the running buffer to reduce the adsorption of protein onto the surface of channel was investigated. Initially, some zwitterionic additives were investigated by making a comparison of relative standard deviations (RSDs) of the migration times for NO2(-) and NO3(-) on capillary electrophoresis. From the results of our comparison of the RSD values, 2% (w/w) N-cyclohexyl-2-aminoethanesulfonic acid (CHES) was selected. As a result of the application of the running buffer with CHES to the MCE process, the complete separation of NO2(-) and NO3(-) in human plasma without deproteinization was achieved within 1 min. Since the RSD values of the positions of the peaks were less than 2.3%, beneficial reduction effects on MCE were suggested. When we used an internal standard method in order to correct the injection volume, the RSDs of the peak heights and areas were less than 10%, and the correlation coefficients of spiked calibration curves ranging from 0 to 350 microM were 0.999 and 0.997 for NO2(-) and NO3(-), respectively. The limits of detection (S/N=3) were 53 microM for NO2(-) and 41 microM for NO3(-). Moreover, the correlation coefficients in excess of 0.99 between the MCE method and a conventional Griess method were achieved for both NO2(-) and NO3(-). Consequently, the possibility of establishing a high-throughput assay process was obtained by utilizing 2% (w/w) CHES to reduce protein adsorption.
Collapse
Affiliation(s)
- Takashi Miyado
- Health Technology Research Center (HTRC), National Institute of Advanced Industrial Science and Technology (AIST), 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577, Japan
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Imre T, Kremmer T, Héberger K, Molnár-Szöllosi E, Ludányi K, Pócsfalvi G, Malorni A, Drahos L, Vékey K. Mass spectrometric and linear discriminant analysis of N-glycans of human serum alpha-1-acid glycoprotein in cancer patients and healthy individuals. J Proteomics 2008; 71:186-97. [PMID: 18617146 DOI: 10.1016/j.jprot.2008.04.005] [Citation(s) in RCA: 56] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2008] [Revised: 04/24/2008] [Accepted: 04/25/2008] [Indexed: 10/22/2022]
Abstract
N-glycan oligosaccharides of human serum alpha(1)-acid glycoprotein (AGP) samples isolated from 43 individuals (healthy individuals and patients with lymphoma and with ovarian tumor) were analyzed by MALDI-TOF mass spectrometry and a multivariate statistical method (linear discriminant analysis, LDA). 34 different glycan structures have been identified. From the glycosylation pattern determined by mass spectrometry fucosylation and branching indices have been calculated. These parameters show only small differences between the patient groups studied, but these differences are not sufficiently large to use as a potential biomarker. LDA analysis, on the other hand shows a very good separation between the three groups (with a classification of 88%). Cross-validation indicates that the method has predictive power: Identifying cancerous vs. healthy individuals shows 96% selectivity and 93% specificity; identification of lymphoma vs. the mixed group of healthy and ovarian tumor cases is also promising (72% selectivity and 84% specificity). The pilot study presented here demonstrates that mass spectrometry combined with linear discriminant analysis (LDA) may provide valuable data for identifying and studying the pathophysiology of malignant diseases.
Collapse
Affiliation(s)
- Tímea Imre
- Institute of Structural Chemistry, Chemical Research Center, Hungarian Academy of Sciences, Budapest, Pusztaszeri u.59-67, Hungary
| | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Fu X, Huang L, Gao F, Li W, Pang N, Zhai M, Liu H, Wu M. Carboxymethyl chitosan-coated capillary and its application in CE of proteins. Electrophoresis 2007; 28:1958-63. [PMID: 17487918 DOI: 10.1002/elps.200600558] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
A hydrophilic basic polysaccharide, carboxymethyl chitosan (CMC) as a capillary coating is presented with a simple preparation procedure. The CMC-coated capillary showed a long lifetime of more than 100 runs, and had good tolerance to some organic solvents, 0.1 M HCl, 0.1 M NaOH, and 5 M urea. The run-to-run, day-to-day, and capillary-to-capillary RSDs for the CMC-coated capillary were all below 2.0% for the determination of EOF. Moreover, the coatings with different concentrations and molecular weights of CMC were also investigated. The CMC-coated capillary was successfully applied to separate basic proteins and recombinant human erythropoietin (rhEPO). Furthermore, several experimental parameters, such as the concentration and pH of the running buffer, temperature, and applied voltage, were optimized for the separation of rhEPO glycoforms. Comparison of an uncoated capillary with chitosan- and CMC-coated capillaries for the separation of rhEPO glycoforms was also discussed. The results demonstrated that rhEPO glycoforms can be well separated by a CMC-coated capillary within 8 min with good reproducibility and resolution. Finally, the volatile BGE HAc-NH4Ac was utilized to separate rhEPO for its further application with CE-MS, achieving a satisfactory result.
Collapse
Affiliation(s)
- Xiaofang Fu
- Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing, PR China
| | | | | | | | | | | | | | | |
Collapse
|
19
|
Geyer H, Geyer R. Strategies for analysis of glycoprotein glycosylation. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS 2006; 1764:1853-69. [PMID: 17134948 DOI: 10.1016/j.bbapap.2006.10.007] [Citation(s) in RCA: 226] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/06/2006] [Revised: 10/18/2006] [Accepted: 10/18/2006] [Indexed: 01/01/2023]
Abstract
Glycoproteins are known to exhibit multiple biological functions. In order to assign distinct functional properties to defined structural features, detailed information on the respective carbohydrate moieties is required. Chemical and biochemical analyses, however, are often impeded by the small amounts of sample available and the vast structural heterogeneity of these glycans, thus necessitating highly sensitive and efficient methods for detection, separation and structural investigation. The aim of this article is to briefly review suitable strategies for characterization of glycosylation at the levels of intact proteins, glycopeptides and free oligosaccharides. Furthermore, methods commonly used for isolation, fractionation and carbohydrate structure analysis of liberated glycoprotein glycans are discussed in the context of potential applications in glycoproteomics.
Collapse
Affiliation(s)
- Hildegard Geyer
- Institute of Biochemistry, Faculty of Medicine, University of Giessen, Friedrichstrasse 24, D-35392 Giessen, Germany
| | | |
Collapse
|
20
|
Lacunza I, Sanz J, Diez-Masa JC, de Frutos M. CZE of human alpha-1-acid glycoprotein for qualitative and quantitative comparison of samples from different pathological conditions. Electrophoresis 2006; 27:4205-14. [PMID: 17022019 DOI: 10.1002/elps.200600304] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Alpha-1-acid glycoprotein (AGP) presents different forms, which may arise from differences in the amino acid sequence and/or in the glycosidic part of the protein. Changes in forms of AGP have been described in literature as a possible tumor marker. While most previous works have approached the study of glycopeptides and/or glycans obtained after fragmentation of the protein, in this work, a CZE method is developed to separate up to eleven peaks of intact forms of AGP. A computer program developed in our laboratory is used to select the migration parameters that make possible an accurate assignment of AGP peaks. Electropherograms of AGP samples purified from sera of cancer patients and healthy donors are qualitatively and quantitatively compared. Percentages of correct assignment of AGP peaks close to 100% are achieved by using either the migration time of each peak relative to that of the EOF marker or the effective electrophoretic mobility of the peaks. The computer program permits to select, among different hypotheses for peak allotment, that one providing the highest accuracy of assignment. In this way, some peaks with different charge-to-mass ratio and a different distribution of area percentage of AGP forms are observed when comparing samples from sick and healthy individuals. Thus, a method that permits to compare AGP forms existing in sera of individuals with different pathophysiological situations has been developed. A potential for using AGP forms analyzed by CZE as a disease marker and for using this technique for screening purposes is envisaged.
Collapse
|
21
|
Matsuno YK, Nakamura H, Kakehi K. Comparative studies on the analysis of urinary trypsin inhibitor (ulinastatin) preparations. Electrophoresis 2006; 27:2486-94. [PMID: 16786482 DOI: 10.1002/elps.200500854] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Urinary trypsin inhibitor (ulinastatin) is a characteristic protein pharmaceutical which contains both glycosaminoglycans and N-linked glycans in its molecule and has been used for treatment of acute pancreatitis. The comparability of ulinastatin preparations of different lots or from different companies was studied by using conventional analytical approaches such as SDS-PAGE, cellulose acetate membrane electrophoresis, and HP size-exclusion chromatography (SEC) and also by using newly developed techniques such as CE and MALDI-TOF MS. The methods using SEC and SDS-PAGE according to The Japanese Pharmacopoeia showed similar molecular masses for two different preparations, and the estimated molecular masses were significantly different from those observed with MALDI-TOF MS. We also showed that the electrophoretic methods using cellulose acetate membrane electrophoresis and CE can be used for comparability assessments of ulinastatin preparations. In addition, we analyzed the unsaturated disaccharides derived from glycosaminoglycan (chondroitin 4-sulfate chain) and N-linked oligosaccharides attached to ulinastatin by CE after releasing them by enzymatic digestion followed by fluorescent labeling with 2-aminoacridone and 2-aminobenzoic acid, respectively. The results indicated that carbohydrate chains are important as markers for comparability assessments of ulinastatin pharmaceutical preparations.
Collapse
Affiliation(s)
- Yu-ki Matsuno
- Faculty of Pharmaceutical Sciences, Kinki University, Higashi-osaka, Japan
| | | | | |
Collapse
|
22
|
Yu B, Cong H, Liu H, Li Y, Liu F. Ionene-dynamically coated capillary for analysis of urinary and recombinant human erythropoietin by capillary electrophoresis and online electrospray ionization mass spectrometry. J Sep Sci 2006; 28:2390-400. [PMID: 16342807 DOI: 10.1002/jssc.200500156] [Citation(s) in RCA: 37] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
In this article, a series of ionene polymers were synthesized and used to coat fused-silica capillaries for the separation of recombinant and urinary human erythropoietin (rhEPO and uEPO) standards by CE. The influence of the charge density of coatings on the separation of rhEPO and uEPO glycoforms was investigated. Then, we further studied the method for fast separation and detection of rhEPO and uEPO standards by CE-ESI-MS. The influence of several CE and MS operating parameters, such as the concentration of CE running buffer, applied external pressure, and the composition and flow rate of sheath liquid on CE-ESI-MS was studied. The results demonstrated that when the capillary was permanently coated with 6,6-ionene and the pH value of acetic acid-ammonium acetate running buffer was 4.80 and 5.50, respectively, a significantly reproducible separation was achieved for rhEPO and uEPO glycoforms. In the online CE-ESI-MS experiments, we not only achieved the online MS signal of uEPO, but also obtained baseline separation of three major rhEPO glycoforms successfully and reproducibly on the 6,6-ionene-coated capillaries. Furthermore, the standard mixture of rhEPO and uEPO was separated, and two incompletely resolved peaks that were identified to be rhEPO and uEPO by the unique MS "fingerprint" were obtained. Additionally, the molecular weight of rhEPO and uEPO were verified and compared to the results by MALDI-TOF-MS. It can be concluded that, in contrast to other indirect methods, the online CE-ESI-MS technique with the combination of the advantages of both CE and MS shows great potential for the separation and detection of rhEPO doping directly in competitive sports.
Collapse
Affiliation(s)
- Bing Yu
- The Key Laboratory of Bioorganic Chemistry and Molecular Engineering of Ministry of Education, College of Chemistry and Molecular Engineering, Peking University, Beijing, China
| | | | | | | | | |
Collapse
|
23
|
Balaguer E, Neusüss C. Glycoprotein Characterization Combining Intact Protein and Glycan Analysis by Capillary Electrophoresis-Electrospray Ionization-Mass Spectrometry. Anal Chem 2006; 78:5384-93. [PMID: 16878873 DOI: 10.1021/ac060376g] [Citation(s) in RCA: 105] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Glycosylated proteins play important roles in a large number of biological processes. Therefore, a complete characterization in terms of glycan structures and glycoform heterogeneity is needed. In this paper, a combined approach based on glycan and intact glycoprotein analysis by capillary zone electrophoresis-electrospray-mass spectrometry (CZE-ESI-MS) is presented. Based on a new capillary coating, a CZE-ESI-MS method for the separation and characterization of intact glycoproteins has been developed and compared to a method recently introduced for the characterization of erythropoietin. The excellent glycoform separation results in high-quality mass spectra, high dynamic range, and good sensitivity, allowing the correct characterization of minor glycan modifications. Additionally, a CZE-ESI-MS separation method for underivatized N-glycans has been developed. The separation of glycans differing in the degree of sialic acids and repeats of noncharged carbohydrates is achieved. The separation power of the method is demonstrated by obtaining mobility differences in glycans differing only by 16 Da. A time-of-flight mass spectrometer allowed the correct identification of the glycan composition based on high mass accuracy and resolution, identifying even minor modifications such as the exchange of "O" by "NH". An ion trap mass spectrometer provided structural information of the underivatized glycans from fragmentation spectra. The general applicability of both methods to glycoprotein analysis is illustrated for erythropoietin, fetuin, and alpha1-acid glycoprotein. The results obtained by the glycan analysis allowed an unequivocal glyco-assignment to the masses obtained for the intact proteins as long as the protein backbone is well characterized. Furthermore, modifications found for intact proteins can be attributed to differences in the glycostructure.
Collapse
|
24
|
Stumpe M, Miller C, Morton NS, Bell G, Watson DG. High-performance liquid chromatography determination of alpha1-acid glycoprotein in small volumes of plasma from neonates. J Chromatogr B Analyt Technol Biomed Life Sci 2006; 831:81-4. [PMID: 16344010 DOI: 10.1016/j.jchromb.2005.11.039] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2005] [Revised: 11/11/2005] [Accepted: 11/19/2005] [Indexed: 11/18/2022]
Abstract
In order to investigate how the alpha1-acid glycoprotein (AGP) concentrations of neonates change in response to surgical stress, a simple high-performance liquid chromatography (HPLC)-assay for the measurement of alpha1-acid glycoprotein levels was developed. A fraction containing alpha1-acid glycoprotein was isolated from the bulk of plasma protein by addition of 0.6M perchloric acid and was then analysed directly on a short PLRP-S 4000A reversed phase column column. The method was validated by analysis of pooled plasma from healthy adults both in comparison with a calibration curve and by standard additions. The procedure was able to isolate alpha1-acid glycoprotein rapidly (<30 min) and required only 50 microl of plasma. The mean extraction recovery was 79.1% (CV 6.4%). The within-run precision for the analysis of three replicates of quality control sample ranged from +/-1.2 to +/-3.8% and the between-run precision was +/-6.1%. The method was linear (r(2)=0.988) over a concentration range from 6 to 100.0 mg/100 ml. The AGP levels in neonatal samples ranged from 25 to 93 mg/100 ml.
Collapse
Affiliation(s)
- M Stumpe
- Department of Pharmaceutical Sciences, Strathclyde Institute of Biomedical Sciences, 27 Taylor St., Glasgow G4 0NR, UK
| | | | | | | | | |
Collapse
|
25
|
Naka R, Kamoda S, Ishizuka A, Kinoshita M, Kakehi K. Analysis of Total N-Glycans in Cell Membrane Fractions of Cancer Cells Using a Combination of Serotonin Affinity Chromatography and Normal Phase Chromatography. J Proteome Res 2005; 5:88-97. [PMID: 16396498 DOI: 10.1021/pr0502976] [Citation(s) in RCA: 58] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Cell surface glycans and recognition molecules of these glycans play important roles in cellular recognition and trafficking, such as in the inflammation response by sialyl LewisX oligosaccharides. Malignant cells also utilize a similar mechanism during colonization and establishment of tumor tissues in the host. These considerations prompt us to develop a screening method for comprehensive analysis of N-glycans derived from membrane fractions of cancer cells. The method involves two step separations. Initially, N-glycans released from cell membrane fractions with N-glycoamidase F were labeled with 2-aminobenzoic acid and separated based on the number of sialic acid residues attached to the oligosaccharides using affinity chromatography on a serotonin-immobilized stationary phase. Each of the nonretarded fractions containing asialo- and high-mannose type oligosaccharides and mono-, di-, tri-, and tetra-sialooligosaccharide fractions which were desialylated with neuraminidase was analyzed by a combination of HPLC using an Amide-80 column as the stationary phase and matrix-assisted laser desorption ionization time-of-flight mass spectrometry (MALDI-TOF MS). We analyzed total N-glycan pools of membrane fractions obtained from some cancer cells, and found that U937 cells (Histocytic lymphoma cells) expressed a large amount of oligosaccharides having polylactosamine residues and MKN45 cells (Gastric adenocarcinoma cells) contained hyper-fucosylated oligosaccharides which contained multiple fucose residues. The method described here will be a powerful technique for glycomics studies in cell surface glycoproteins, and will enable one to search marker oligosaccharides characteristically observed in various diseases such as cancer, inflammation, and congenital disorder.
Collapse
Affiliation(s)
- Ryosuke Naka
- Faculty of Pharmaceutical Sciences, Kinki University, Kowakae 3-4-1, Higashi-Osaka 577-8502, Japan
| | | | | | | | | |
Collapse
|
26
|
Berkowitz SA, Zhong H, Berardino M, Sosic Z, Siemiatkoski J, Krull IS, Mhatre R. Rapid quantitative capillary zone electrophoresis method for monitoring the micro-heterogeneity of an intact recombinant glycoprotein. J Chromatogr A 2005; 1079:254-65. [PMID: 16038312 DOI: 10.1016/j.chroma.2005.03.068] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
A simple high-resolution capillary zone electrophoresis (CZE) method capable of rapidly assessing the micro-heterogeneity of a 24 kDa molecular weight glycoprotein, has been developed. Separation is carried out using a bare silica capillary at a pH of 2.5 in a commercially available electrophoresis buffer system composed of triethanolamine and phosphoric acid. Over 30 peaks were detected within a run time of 15 min using a 27 cm capillary and approximately 60 peaks were detected using a 77 cm capillary. Although most of the peaks arise from differences in the oligosaccharide structures present on the one glycosylation site on this molecule, other forms of micro-heterogeneity due to the presence of the nonglycosylated form of this glycoprotein and various types of chemical degradation, e.g., deamidation, are also responsible for the multitude of peaks observed. Although the exact chemical identity of each peak in the resulting electropherogram of this glycoprotein is not known, useful information can be obtained for assessing comparability, stability, and batch consistency. Factors impacting the resolution, precision, accuracy, and robustness of the assay are also discussed along with inherent advantages and limitations associated with measuring the micro-heterogeneity of intact glycoproteins.
Collapse
Affiliation(s)
- Steven A Berkowitz
- Department of Analytical Development, Biogen Idec Inc., 14 Cambridge Center, Cambridge, MA 02142, USA.
| | | | | | | | | | | | | |
Collapse
|
27
|
Sanz-Nebot V, Benavente F, Giménez E, Barbosa J. Capillary electrophoresis and matrix-assisted laser desorption/ionization-time of flight-mass spectrometry for analysis of the novel erythropoiesis-stimulating protein (NESP). Electrophoresis 2005; 26:1451-6. [PMID: 15759304 DOI: 10.1002/elps.200410092] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
NESP (novel erythropoiesis-stimulating protein) is a recently approved hyperglycosylated analogue of human erythropoietin (EPO) with a long-lasting effect. In this work, the capillary electrophoresis (CE) methodology proposed by the European Pharmacopoeia for the separation of EPO glycoforms has been modified for the separation of NESP glycoforms. Optimization of pH of the separation electrolyte has been fundamental in order to achieve baseline resolution of seven peaks corresponding to NESP glycoforms. Intact NESP has also been characterized by matrix-assisted laser desorption/ionization-time of flight-mass spectrometry (MALDI-TOF-MS). An accurate approximation to an average molecular mass of the NESP molecule has been obtained, taking into account the strong influence of laser intensity upon the MALDI-TOF mass spectra found.
Collapse
Affiliation(s)
- Victoria Sanz-Nebot
- Department of Analytical Chemistry, University of Barcelona, Barcelona, Spain.
| | | | | | | |
Collapse
|
28
|
Abstract
The present mini-review summarizes the experience gathered by our group in developing different classes of novel quaternarized heterocyclic compounds able to modulate and reverse the electroendoosmotic flow (EOF) in a most peculiar manner. The first class comprises mono-salt compounds, with the determinant omega-iodoalkyl chains of different lengths (typically C4-C8), able to be adsorbed by silicas, at alkaline pH, and spontaneously alkylate ionised silanols, thus becoming covalently affixed to it. The second class is constituted by di-salt compounds, attached at the termini of an alkyl chain of variable lengths (here too, typically, C4-C8). This second class is unable to bind covalently silica surfaces, although, in thin-layer chromatography, it exhibits an extraordinary affinity for silica beads, contrary to the first one. On the basis of the strikingly different behaviour, structural rules are derived for the minimum requirements for general classes of amines to bind to silica walls and modify EOF. For compounds unable to bind covalently to the wall, the most important structural motif is two quaternary nitrogens spaced apart by a C4 chain: this seems to be the average distance (i.e., 0.8 nm) between two adjacent, ionized silanols for a snug fit. The other structural binding motif is the "hydrophobic decoration", i.e., the ratio of charged groups to alkyl residue in the various amines; amines with high levels of such alkane groups (i.e., with higher hydrophobicity), seem to bind more tenaciously to the wall, probably due to hydrophobic interaction not to the wall but among the amine derivatives themselves, when carpeting the silica.
Collapse
Affiliation(s)
- Pier Giorgio Righetti
- Department of Agricultural and Industrial Biotechnology, University of Verona, Strada Le Grazie 15, Verona 37134, Italy
| | | | | | | |
Collapse
|
29
|
Nagy K, Vékey K, Imre T, Ludányi K, Barrow MP, Derrick PJ. Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometry of Human α-1-Acid Glycoprotein. Anal Chem 2004; 76:4998-5005. [PMID: 15373434 DOI: 10.1021/ac040019a] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The ultrahigh resolution and sensitivity of electrospray ionization Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry have for the first time been exploited for the characterization of highly sialylated glycoproteins, using human alpha-1-acid glycoprotein as the model compound. An alternative approach to the widely used high-performance liquid chromatography (HPLC) and matrix-assisted laser desorption/ionization (MALDI) assays is described. This new method does not require any enzymatic or chemical digestion (removal of sialyl groups or deglycosylation), chemical derivatization (introduction of chromophore groups), or preliminary chromatographic separation (HPLC or electrophoresis). Following ESI and accumulation of ions in a hexapole ion guide, ions are injected into the ICR cell. A selected mass window from the overall ion population is isolated and axialized prior to detection. After acquisition and Fourier transform of the transient signal the resulted spectrum is evaluated in order to determine the charge state of the detected ions and the isotope pattern of the measured protein glycoform. The presence of ions from the same glycoform with different charge states was confirmed. The advantages and limitations of the technique are discussed. Future prospects and possible applications are indicated.
Collapse
Affiliation(s)
- Kornél Nagy
- Institute of Chemistry, Chemical Research Center, Hungarian Academy of Sciences, H-1025 Pusztaszeri út 59-67, Budapest, Hungary
| | | | | | | | | | | |
Collapse
|
30
|
Sanz-Nebot V, Benavente F, Vallverdú A, Guzman NA, Barbosa J. Separation of Recombinant Human Erythropoietin Glycoforms by Capillary Electrophoresis Using Volatile Electrolytes. Assessment of Mass Spectrometry for the Characterization of Erythropoietin Glycoforms. Anal Chem 2003; 75:5220-9. [PMID: 14708798 DOI: 10.1021/ac030171x] [Citation(s) in RCA: 60] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The separation of the glycoforms of erythropoietin (EPO) by capillary electrophoresis (CE) was recently published as a monograph by the European Pharmacopoeia (European Pharmacopoeia 4 2002, 1316, 1123-1128). Although the experimental CE conditions employed a background electrolyte containing additives suitable for on-line UV-absorption detection, they were not appropriate for on-line mass spectrometry (MS) detection. In this work, an attempt was made to investigate experimental conditions employing volatile electrolyte systems to achieve the separation and characterization of EPO glycoforms using CE and ESI-MS methodologies. The influence of several operating conditions, such as the coating of the internal walls of the capillary as well as the composition, concentration, and the pH of the separation buffer were investigated. The results demonstrated that when the internal walls of the capillaries were permanently coated with Polybrene and a buffer electrolyte containing 400 mM of HAc-NH4Ac (acetic acid-ammonium acetate), pH 4.75, was used, a significantly reproducible separation was achieved for EPO glycoforms. Intact EPO was characterized by two mass spectrometry techniques: electrospray ionization (ESI-MS) and matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF-MS). The data demonstrated that MALDI-TOF-MS provided a good approximation to an average molecular mass of the EPO molecule. However, it was still necessary to carry out further separation of the intact EPO glycoforms in order to obtain molecular mass information when ESI-MS was used.
Collapse
Affiliation(s)
- Victoria Sanz-Nebot
- Department of Analytical Chemistry, University of Barcelona, 08028 Barcelona, Spain.
| | | | | | | | | |
Collapse
|
31
|
Schmidt CA, Ramos AS, Silva JED, Fronza M, Dalmora SL. Avaliação da atividade e caracterização de eritropoietina humana recombinante em produtos farmacêuticos. ACTA ACUST UNITED AC 2003. [DOI: 10.1590/s0004-27302003000200012] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Realizou-se a identificação de eritropoietina humana recombinante em produtos farmacêuticos comerciais por eletroforese em gel de poliacrilamida e detecção com anticorpos específicos, demonstrando-se típica banda larga, semelhante ao padrão de rhEPO da Farmacopéia Européia. Igualmente por focalização isoelétrica e imunodetecção, observaram-se 5-6 isoformas características de acordo com o laboratório produtor. A avaliação de potência efetuada através de ensaio biológico em camundongos normocitêmicos forneceu valores entre 67,6% e 119,4% em relação à declarada. A precisão dos ensaios combinados, calculada pela ponderação, variou de 200 a 389. Os testes de endotoxinas bacterianas, toxicidade e pH apresentaram valores variáveis conforme o lote. Concluiu-se destacando a importância dos testes e ensaios de controle para assegurar a qualidade lote a lote e garantir a eficácia terapêutica dos produtos farmacêuticos.
Collapse
|
32
|
Dang F, Zhang L, Hagiwara H, Mishina Y, Baba Y. Ultrafast analysis of oligosaccharides on microchip with light-emitting diode confocal fluorescence detection. Electrophoresis 2003; 24:714-21. [PMID: 12601743 DOI: 10.1002/elps.200390086] [Citation(s) in RCA: 82] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
We have developed a new method for the high-speed separation and high-sensitivity detection of complex oligosaccharides based on microchip electrophoresis (nu-CE) with light-emitting diode (LED) confocal fluorescence detection. Oligosaccharides labeled with 8-aminopyrene-1,3,6-trisulfonate (APTS) were found to strongly adsorb to the surface of polymethylmethacrylate (PMMA) microchips. Accordingly, three classes of major dynamic coating additives were systematically investigated, and cellulose derivatives were found to specifically suppress such adsorption and allow high-performance separation on PMMA chips. Additive concentration, buffer pH and applied field strength were found to be key factors in the high-performance separation& of APTS-labeled oligosaccharides on PMMA chips. Under optimal conditions, 15 oligosaccharides in dextrin hydrolysate can be separated within 45 s with an electrophoretic separation efficiency of over 400 000 theoretical plates per meter. The relative standard deviation (RSD) values of migration times of fourteen oligosaccharides were less than 0.50% between six different channels, and the detection limit for APTS-labeled glucose was about 1.98 x 10(-8) mol/L or 8.61 amol with a signal-to-noise ratio (S/N) of 3. The high speed, high efficiency and high sensitivity of this micro-CE-based method indicate that it can be widely applied to analysis of complex oligosaccharides.
Collapse
Affiliation(s)
- Fuquan Dang
- Department of Medicinal Chemistry, Faculty of Pharmaceutical Sciences, The University of Tokushima, Tokushima, Japan.
| | | | | | | | | |
Collapse
|
33
|
Nakajima K, Oda Y, Kinoshita M, Kakehi K. Capillary affinity electrophoresis for the screening of post-translational modification of proteins with carbohydrates. J Proteome Res 2003; 2:81-8. [PMID: 12643546 DOI: 10.1021/pr020009v] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Glycosylation is one of the most important post-translational events for proteins, affecting their functions in health and disease, and plays significant roles in various information traffics for intracellular and intercellular biological events (Hancock, W. S. J. Proteome Res. 2002, 1, 297). We have attempted to obtain the information on the numbers and amounts of carbohydrate chains. Interaction between carbohydrate chains and proteins that recognize them is a target to understand the biological roles of glycosylation. To date, there have been a few strategies for simultaneous analysis of the interactions between complex mixtures of carbohydrates and proteins. Here, we report an approach to categorize carbohydrate chains using a few glycoprotein samples as models for the studies on the analysis of post-translational modification of proteins with carbohydrates. A combination of some specific lectins was used as carbohydrate-binding proteins. The method is based on high-resolution separation of fluorescent-labeled carbohydrates by capillary electrophoresis with laser-induced fluorescent detection in the presence of carbohydrate-binding proteins at different concentrations. The present technique affords (1) simultaneous determination of carbohydrate chains, (2) binding specificity of the constituent carbohydrate chains to specific proteins, and (3) kinetic data such as the association constant of each carbohydrate. We found that the lectins employed in the present study could discriminate subtle difference in linkages and resolved the carbohydrate mixtures. The results will be useful, for example, to understand the biological events expressed with carbohydrate changes on the cell surface.
Collapse
Affiliation(s)
- Kazuki Nakajima
- Faculty of Pharmaceutical Sciences, Kinki University, Kowakae 3-4-1, Higashi-osaka 577-8502, Japan
| | | | | | | |
Collapse
|
34
|
Sei K, Nakano M, Kinoshita M, Masuko T, Kakehi K. Collection of alpha1-acid glycoprotein molecular species by capillary electrophoresis and the analysis of their molecular masses and carbohydrate chains. Basic studies on the analysis of glycoprotein glycoforms. J Chromatogr A 2002; 958:273-81. [PMID: 12134825 DOI: 10.1016/s0021-9673(02)00353-9] [Citation(s) in RCA: 39] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
A highly heterogeneous glycoprotein, alpha1-acid glycoprotein, was resolved into their glycoforms by capillary electrophoresis using a surface-modified capillary in 20 mM acetate buffer (pH 4.2) containing 0.5% (w/v) hydroxypropylmethylcellulose. We collected the fractions containing each glycoform as nearly pure state by capillary electrophoresis, and examined the molecular masses of these glycoforms by matrix assisted laser desorption time-of-flight mass spectrometry. We also analyzed carbohydrate chains after releasing them with N-glycosidase F followed by fluorescent labeling with 8-aminopyrene-1,3,6-trisulfonate. We found that the separation of glycoforms was mostly due to the presence of multiantennary carbohydrate chains. We propose that the present technique is useful for the analysis of post translational modification of proteins with carbohydrate chains.
Collapse
Affiliation(s)
- Kazuo Sei
- Faculty of Pharmaceutical Sciences, Kinki University, Higashi-Osaka, Japan
| | | | | | | | | |
Collapse
|
35
|
Kawasaki N, Ohta M, Itoh S, Hyuga M, Hyuga S, Hayakawa T. Usefulness of sugar mapping by liquid chromatography/mass spectrometry in comparability assessments of glycoprotein products. Biologicals 2002; 30:113-23. [PMID: 12127313 DOI: 10.1006/biol.2002.0324] [Citation(s) in RCA: 35] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
We have previously reported that sugar-mapping by liquid chromatography/mass spectrometry (LC/MS) equipped with a graphitized carbon column (GCC) can be useful for structural analysis of carbohydrates in a glycoprotein. In this paper, we evaluated sugar-mapping with regard to its use in comparability assessment of glycoprotein products. Erythropoietins (EPO) produced from three different sources were chosen as models of the closely related glycoprotein products. The two-dimensional displays of sugar maps drawn by LC/MS with GCC clearly showed the differences in carbohydrate heterogeneity with regard to sialylation, acetylation, and sulphation patterns among three EPOs. Exoglycosidase digestion followed by sugar-mapping provided information regarding the structure of characteristic carbohydrates in each EPO. These results demonstrate that LC/MS with GCC can reveal the details of carbohydrate heterogeneity in order to distinguish between closely related glycoprotein products. Our method can thus be useful in comparability assessments of therapeutic glycoproteins.
Collapse
Affiliation(s)
- Nana Kawasaki
- Division of Biological Chemistry and Biologicals, National Institute of Health Sciences, 1-18-1, Kamiyoga, Setagaya-ku, Tokyo, 158-8501, Japan.
| | | | | | | | | | | |
Collapse
|
36
|
Kakehi K, Kinoshita M, Nakano M. Analysis of glycoproteins and the oligosaccharides thereof by high-performance capillary electrophoresis-significance in regulatory studies on biopharmaceutical products. Biomed Chromatogr 2002; 16:103-15. [PMID: 11857643 DOI: 10.1002/bmc.150] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
This review describes the recent development in the analysis of glycoproteins using capillary electrophoresis with various separation techniques, and focuses especially on the analysis of recombinant glycoprotein pharmaceuticals. We include the analysis of glycoprotein multiforms (ie glycoform) as well as glycan analysis. The relationship between glycoprotein multiforms and oligosaccharide distributions in a glycoprotein sample is also discussed. Further, recent development in capillary electrophoresis-mass spectrometry is described.
Collapse
Affiliation(s)
- Kazuaki Kakehi
- Faculty of Pharmaceutical Sciences, Kinki University, Kowakae 3-4-1, Higashi-osaka 577-8502, Japan.
| | | | | |
Collapse
|
37
|
Progent F, Taverna M, Le Potier I, Gopée F, Ferrier D. A study of the binding between polymers and peptides, using affinity capillary electrophoresis, applied to polymeric drug delivery systems. Electrophoresis 2002; 23:938-44. [PMID: 11920880 DOI: 10.1002/1522-2683(200203)23:6<938::aid-elps938>3.0.co;2-7] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
We have investigated the potential of affinity capillary electrophoresis (ACE) to evaluate binding constants between an anionic polydispersed polymer and four peptides. Nonlinear regression and three current linearization methods, the y-reciprocal, the x-reciprocal and the double-reciprocal, were employed for the estimation of the binding constants. The x-reciprocal and the double-reciprocal plots indicated the presence of two portions of straight lines for angiopeptin, triptorelin and the thyrotropin releasing hormone (TRH), and therefore the probable existence of a second-order interaction which causes the deviation from the 1:1 model. Peptide 1 exhibited a unique binding constant of 2.4 x 10(6)M(-1). In contrast, angiopeptin, triptorelin and TRH exhibited a K(1) of 4.0 x 10(6), 5.3 x 10(6) and 20.2 x 10(6)M(-1), respectively, and a K(2) of 0.4 x 10(6), 0.5 x 10(6) and 1.4 x 10(6)M(-1), respectively. The origin of the high scattering of the data points was further investigated. Neither the viscosity, nor the adsorption of the peptides to the capillary wall appeared to be the determining factor of data scattering. Finally, a possible adsorption of the polymer leading to the electroosmotic flow instability was supposed.
Collapse
Affiliation(s)
- Frédéric Progent
- Groupe de Chimie Analytique de Paris Sud, Faculté de Pharmacie de Paris XI, rue J. B. Clement, F-92290 Châtenay-Malabry, France
| | | | | | | | | |
Collapse
|
38
|
Affiliation(s)
- Yehia Mechref
- Department of Chemistry, Indiana University, Bloomington, Indiana 47405, USA
| | | |
Collapse
|
39
|
Tran NT, Cabanes-Macheteau M, Taverna M. Chapter 20 Analysis of glycoproteins and their glycopeptide and glycan fragments by electrophoresis and capillary electrophoresis. JOURNAL OF CHROMATOGRAPHY LIBRARY 2002. [DOI: 10.1016/s0301-4770(02)80045-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
|
40
|
Abstract
This review article with 223 references describes recent developments in capillary electrophoresis (CE) of proteins and covers papers published during last two years, from the previous review (V. Dolnik, Electrophoresis 1999, 20, 3106-3115) through Spring 2001. It describes the topics related to CE of proteins including modeling of the electrophoretic properties of proteins, sample pretreatment, wall coatings, improving selectivity, detection, special electrophoretic techniques, and applications.
Collapse
Affiliation(s)
- V Dolnik
- Molecular Dynamics, Sunnyvale, CA 94085, USA.
| | | |
Collapse
|
41
|
Patrick JS, Lagu AL. Review applications of capillary electrophoresis to the analysis of biotechnology-derived therapeutic proteins. Electrophoresis 2001; 22:4179-96. [PMID: 11824636 DOI: 10.1002/1522-2683(200111)22:19<4179::aid-elps4179>3.0.co;2-8] [Citation(s) in RCA: 48] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The number of proteins produced by recombinant DNA technology continues to grow at a rapid pace. In this review, the emphasis is on proteins that are of therapeutic interest. Aspects of protein analysis, such as glycoform separation of proteins produced in mammalian cells and the separation of oligosaccharides for structure elucidation, are covered. The use of antibodies as therapeutic proteins is growing and currently antibodies are the largest class of proteins produced by biotechnology. This has merited a separate section on analysis of antibodies by capillary electrophoresis (CE). Applications of mass spectrometry as an ancillary technique, used in conjunction with CE, are also covered briefly. This review covers the literature since 1999.
Collapse
Affiliation(s)
- J S Patrick
- Lilly Research Laboratories, A Division of Eli Lilly and Co., Indianapolis, IN 46285, USA
| | | |
Collapse
|
42
|
Kakehi K, Kinoshita M, Kawakami D, Tanaka J, Sei K, Endo K, Oda Y, Iwaki M, Masuko T. Capillary electrophoresis of sialic acid-containing glycoprotein. Effect of the heterogeneity of carbohydrate chains on glycoform separation using an alpha1-acid glycoprotein as a model. Anal Chem 2001; 73:2640-7. [PMID: 11403311 DOI: 10.1021/ac001382u] [Citation(s) in RCA: 55] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Abstract
alpha1-Acid glycoprotein (AGP) showed multiple peaks on separation using capillary electrophoresis in a chemically modified capillary with dimethylpolysiloxane at slightly acidic conditions. We analyzed glycoforms of AGP species after separation by ion-exchange chromatography, Con A affinity chromatography, and Cu(II)-chelating affinity chromatography. The AGP species thus obtained were digested with N-glycosidase F, and the released carbohydrate chains were analyzed by high-performance liquid chromatography after labeling with 3-aminobenzoic acid. The results afforded basic information on the contribution of carbohydrate chains to the separation mechanism of glycoforms of AGP by capillary electrophoresis. In addition, we describe an easy method for AGP analysis in serum samples using the electrokinetic injection.
Collapse
Affiliation(s)
- K Kakehi
- Faculty of Pharmaceutical Sciences, Kinki University, Higashi-Osaka, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Eriksson HJ, Somsen GW, Hinrichs WL, Frijlink HW, de Jong GJ. Characterization of human placental alkaline phosphatase by activity and protein assays, capillary electrophoresis and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 755:311-9. [PMID: 11393719 DOI: 10.1016/s0378-4347(01)00136-0] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Placental alkaline phosphatase (PLAP) that had been isolated from human placenta was further purified using subsequent ion-exchange chromatography (IEC), affinity chromatography (AC) and centrifugal membrane concentration (CMC). During the process, the PLAP samples from the different stages of purification were characterized regarding purity and activity. This was accomplished by combining Lowry analysis, enzymatic activity assay, capillary zone electrophoresis (CZE), capillary gel electrophoresis (CGE) and matrix-assisted laser desorption/ionisation time of flight mass spectrometry (MALDI-TOF-MS). The sample obtained after IEC had a rather low specific activity (6.8 U/mg) and appeared to contain several major contaminants, among which was human serum albumin (HSA). AC followed by CMC yielded PLAP with a specific activity of 128 U/mg. The purity and identity of the protein was indicated by MALDI-TOF-MS yielding a spectrum with one major peak at m/z 58,101. Interestingly, CZE of the pure PLAP revealed a cluster of peaks, which probably reflects the presence of various glycoforms and/or oligomers. The same analytical approach was used to characterize commercially available PLAP. This sample showed a moderate specific activity (15 U/mg) and appeared to be highly impure containing various other proteins.
Collapse
Affiliation(s)
- H J Eriksson
- Department of Pharmaceutical Analysis, University of Groningen, The Netherlands
| | | | | | | | | |
Collapse
|
44
|
Pacáková V, Hubená S, Tichá M, Mad ra M, Stulík K. Effects of electrolyte modification and capillary coating on separation of glycoprotein isoforms by capillary electrophoresis. Electrophoresis 2001; 22:459-63. [PMID: 11258755 DOI: 10.1002/1522-2683(200102)22:3<459::aid-elps459>3.0.co;2-p] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The capillary electrophoresis (CE) running electrolyte composition was optimized for the separation of selected glycoproteins. A good separation of the ovalbumin (OV) and alpha-acid glycoprotein (AAG) isoforms was achieved in 20 mmol x L(-1) N-(2-hydroxyethyl)piperazine-2'-(2-ethanesulfonic acid) (HEPES) at pH 7.0, in 20 mmol x L(-1) phosphate, pH 7.0, or in 25 mmol x L(-1) borate, pH 7.9. Various ways of suppression of the glycoprotein adsorption onto the capillary wall were compared. Alpha, omega-diamine alkanes and bis(aminoalkyl) amines were added to the CE buffers, the optimized concentration being 1 mmol x L(-1) in 20 mmol x L(-1) phosphate buffer. The OV and AAG isoforms could be separated using all the alpha,omega-diamine alkanes or bis(2-aminoethyl)amine. The length of the alkyl chain in the diaminoalkane did not influence the separation. The separation of the isoforms of pollen allergens was also tested. The effects of modification of the capillary wall by succinyl-poly-L-lysine and hydrophilic CElect-P1 capillary were compared. A decrease in the glycoprotein and protein adsorption resulted in an improved separation of the isoforms.
Collapse
Affiliation(s)
- V Pacáková
- Department of Analytical Chemistry, Faculty of Sciences, Charles University, Prague, Czech Republic.
| | | | | | | | | |
Collapse
|
45
|
Guzman NA. Determination of immunoreactive gonadotropin-releasing hormone in serum and urine by on-line immunoaffinity capillary electrophoresis coupled to mass spectrometry. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2000; 749:197-213. [PMID: 11145057 DOI: 10.1016/s0378-4347(00)00410-2] [Citation(s) in RCA: 68] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The need for urgent diagnoses has propelled the development of automated analyses that can be performed in a short time at reasonable cost. One such method is immunoaffinity capillary electrophoresis. This emerging hybrid technology employs two powerful techniques coupled on-line for the direct and rapid determination of analytes present in biological fluids. The first technique, immunoaffinity, is used for the selective extraction of a molecule present in a complex matrix, utilizing a microscale-format chamber affinity device. An analyte (affinity target) present in serum or urine is captured by an immobilized molecular recognition antibody molecule (affinity ligand) bound to a solid support constituent (glass beads or an appropriate porous structure) of a microchamber affinity device. The second technique, capillary electrophoresis, is used for the high-resolution analytical separation of the purified and concentrated affinity target material after elution from the microchamber affinity device. In this work, immunoaffinity capillary electrophoresis was developed for the identification and characterization of a single constituent of a complex matrix. Immunoreactive gonadotropin-releasing hormone was determined in serum and urine specimens derived from a normal individual and from a patient suffering from benign prostatic hyperplasia. Furthermore, the on-line immuno-separation system was coupled in tandem to mass spectrometry to obtain molecular mass information of the affinity isolated and CE separated neuropeptide. This hybrid immuno-analytical technology is simple, rapid, selective and sensitive. In addition, an attempt was also made to characterize other urinary constituents by CE-MS that may lead to marker activity in the urine of the diseased subject. The hyphenation of analytical techniques has proved valuable in enhancing their individual features. The future of bioanalysis using miniaturized affinity systems is discussed in this paper.
Collapse
Affiliation(s)
- N A Guzman
- Bioanalytical Drug Metabolism, The R.W. Johnson Pharmaceutical Research Institute, Raritan, NJ 08896, USA.
| |
Collapse
|