1
|
Perfusate Analysis During Dual Hypothermic Oxygenated Machine Perfusion of Liver Grafts: Correlations With Donor Factors and Early Outcomes. Transplantation 2020; 104:1929-1942. [PMID: 32769628 DOI: 10.1097/tp.0000000000003398] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
BACKGROUND Liver graft viability assessment has long been considered a limit of hypothermic oxygenated machine perfusion (HOPE). Aim of this study was assessing correlations of easily available perfusate parameters (PP) (aspartate aminotransferase, alanine aminotransferase, lactate dehydrogenase, glucose, lactate, and pH) with graft features and outcome. METHODS In the period October 2018-February 2020, perfusate samples were obtained every 30 minutes during 50 dual-HOPE (D-HOPE) procedures. Correlations of PP with graft factors, 90-day graft loss, early allograft dysfunction (EAD), L-GrAFT score, acute kidney injury, and comprehensive complication index were analyzed using Pearson coefficient, receiver-operating characteristics analysis and by univariable and multivariable regression. RESULTS Median D-HOPE time was 122 minutes. All parameters were normalized to liver weight. Only macrovesicular steatosis (MaS) significantly impacted PP levels and slope. Grafts with ≥30% MaS exhibited significantly different PP values and slope. Graft loss and EAD rate were 2% (n = 1) and 26% (n = 13). All PP except lactate correlated with EAD, 90-minute alanine aminotransferase showing the highest area under the receiver-operating characteristics curve (0.84). However, at multivariable analysis, the only factor independently associated with EAD was MaS (odds ratio, 5.44; confidence interval, 1.05-28.21; P = 0.04). Ninety minutes lactate dehydrogenase had the strongest correlation with L-GrAFT (R = 0.70; P < 0.001). PP correlated poorly with comprehensive complication index and grades 2-3 acute kidney injury rate. CONCLUSIONS PP were predictive of graft function after transplant, but their association with graft survival and clinical outcomes requires further evaluation. MaS influenced levels of PP and was the only independent predictor of EAD.
Collapse
|
2
|
Kidney Perfusion as an Organ Quality Assessment Tool-Are We Counting Our Chickens Before They Have Hatched? J Clin Med 2020; 9:jcm9030879. [PMID: 32210197 PMCID: PMC7141526 DOI: 10.3390/jcm9030879] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 03/16/2020] [Accepted: 03/19/2020] [Indexed: 02/07/2023] Open
Abstract
The final decision to accept an organ for transplantation remains a subjective one. With “poor organ quality” commonly cited as a major reason for kidney discard, accurate, objective, and reliable quality assessment is essential. In an era of increasingly higher-risk deceased donor kidneys, the catch is to accept those where the risk–benefit scale will tip in the right direction. Currently available assessment tools, such as risk-scores predicting outcome and zero-time biopsy, perform unsatisfactory, and assessment options during static cold storage are limited. Kidney perfusion technologies are finding their way into clinical practice, and they bring a new opportunity to assess kidney graft viability and quality, both in hypothermic and normothermic conditions. We give an overview of the current understanding of kidney viability assessment during ex situ kidney perfusion. A pragmatic framework to approach viability assessment is proposed as an interplay of three different compartments: the nephron, the vascular compartment, and the immune compartment. Although many interesting ways to assess kidney injury and function during perfusion have been proposed, none have reached the stage where they can reliably predict posttransplant outcome. Larger well-designed studies and validation cohorts are needed to provide better guidance.
Collapse
|
3
|
Guzzi F, Knight SR, Ploeg RJ, Hunter JP. A systematic review to identify whether perfusate biomarkers produced during hypothermic machine perfusion can predict graft outcomes in kidney transplantation. Transpl Int 2020; 33:590-602. [PMID: 32031281 DOI: 10.1111/tri.13593] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2019] [Revised: 11/06/2019] [Accepted: 02/05/2020] [Indexed: 02/06/2023]
Abstract
There is good evidence to support the use of hypothermic machine perfusion (HMP) over static cold storage as the favoured preservation method for deceased donor kidneys. However, the utility of HMP as a tool to assess the viability of kidneys for transplant is unclear. There is a need to determine whether perfusate biomarkers produced during HMP can predict post-transplant outcomes and assess the suitability of organs for transplantation. Three different databases (MEDLINE, Embase, Transplant Library) were screened to 31 May 2019. Articles were included if a relationship was reported between one or more perfusate biomarkers and post-transplant outcomes. Studies were assessed and graded for methodological quality and strength of evidence. Glutathione S-transferase was the most promising biomarker for predicting delayed graft function, but its predictive ability was at best moderate. Analysis of primary nonfunction rates was challenging due to low occurrence rates and small sample sizes. Existing studies are limited in quality and have not yielded biomarkers for kidneys undergoing HMP that are able to predict post-transplant outcomes with sufficient accuracy to support routine clinical use. Further studies with larger samples and more robust methodology are needed. (PROSPERO registration: CRD42019121161).
Collapse
Affiliation(s)
- Francesco Guzzi
- Nuffield Department of Surgical Sciences, Oxford Transplant Centre, Churchill Hospital, University of Oxford, Oxford, UK.,Department of Biomedical Experimental and Clinical Sciences "Mario Serio", University of Florence, Florence, Italy
| | - Simon R Knight
- Nuffield Department of Surgical Sciences, Oxford Transplant Centre, Churchill Hospital, University of Oxford, Oxford, UK
| | - Rutger J Ploeg
- Nuffield Department of Surgical Sciences, Oxford Transplant Centre, Churchill Hospital, University of Oxford, Oxford, UK.,Oxford Biomedical Research Centre, Oxford, UK
| | - James P Hunter
- Nuffield Department of Surgical Sciences, Oxford Transplant Centre, Churchill Hospital, University of Oxford, Oxford, UK
| |
Collapse
|
4
|
Wszola M, Domagala P, Serwanska-Swietek M, Ostaszewska A, Perkowska-Ptasinska A, Piatek T, Gozdowska J, Durlik M, Chmura A, Kwiatkowski A. Should Immunosuppression After Kidney Transplant Be Adjusted Based on Renal Resistance During Pretransplant Hypothermic Machine Perfusion? Transplant Proc 2019; 51:2676-2682. [PMID: 31477422 DOI: 10.1016/j.transproceed.2019.01.202] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2018] [Accepted: 01/04/2019] [Indexed: 11/28/2022]
Abstract
BACKGROUND The hypothermic machine perfusion reduces delayed graft function after kidney transplant and allows, to some extent, predicting early graft function. However, it is difficult to identify exact perfusion criteria with which to exclude kidneys from transplant or modify post-transplant care. The aim of this study was to analyze whether renal resistance during the fourth hour of hypothermic machine perfusion is useful in the prediction of graft survival and acute rejection. PATIENTS AND METHODS Data on pretransplant hypothermic machine perfusion parameters of 407 transplanted kidneys were available. Receiver operating characteristic curve analysis was performed to find an optimal cutoff value of ratio for predicting a higher risk class of considered group of patients. According to this, patients were divided into 2 groups: those who received kidneys with renal resistance lower than 0.19 mm Hg/mL/min (R1; n = 187) and those who received kidneys with renal resistance equal to or higher than 0.19 mm Hg/mL/min (R2; n = 220). Within R2, we additionally analyzed 2 subgroups: patients who received induction therapy (R2-Ind+; n = 124) and those who did not received induction therapy (R2-Ind-; n = 96). RESULTS Acute rejection in R1 within 1 month post transplant was 2-fold lower compared with R2 and was 6.4% vs 13.1% (P = .03), respectively. One-year graft survival was higher in R1 compared with R2 and was 94.6% vs 88.5% (P = .03), respectively. Acute rejection in the R2-Ind+ subgroup within 1 month post transplant was 2.46-fold lower compared with the R2-Ind- subgroup and was 8% vs 19.7% (P = .01), respectively. CONCLUSION Immunosuppression treatment after transplant should be adjusted to perfusion parameters.
Collapse
Affiliation(s)
- Michal Wszola
- Foundation of Research and Science Development, Otwock, Poland
| | - Piotr Domagala
- Department of General and Transplantation Surgery, Medical University of Warsaw, Poland.
| | | | - Agata Ostaszewska
- Foundation of Research and Science Development, Otwock, Poland; Department of General and Transplantation Surgery, Medical University of Warsaw, Poland
| | | | - Tomasz Piatek
- Department of Surgical & Transplant Nursing, Medical University of Warsaw, Poland
| | - Jolanta Gozdowska
- Department of Transplant Medicine and Nephrology and Internal Diseases, Medical University of Warsaw, Poland
| | - Magdalena Durlik
- Department of Transplant Medicine and Nephrology and Internal Diseases, Medical University of Warsaw, Poland
| | - Andrzej Chmura
- Department of General and Transplantation Surgery, Medical University of Warsaw, Poland
| | - Artur Kwiatkowski
- Foundation of Research and Science Development, Otwock, Poland; Department of General and Transplantation Surgery, Medical University of Warsaw, Poland
| |
Collapse
|
5
|
Wszola M, Domagala P, Ostaszewska A, Gorski L, Karpeta E, Berman A, Sobol M, Durlik M, Chmura A, Kwiatkowski A. Time of Cold Storage Prior to Start of Hypothermic Machine Perfusion and Its Influence on Graft Survival. Transplant Proc 2019; 51:2514-2519. [PMID: 31473005 DOI: 10.1016/j.transproceed.2019.02.052] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Revised: 01/22/2019] [Accepted: 02/06/2019] [Indexed: 01/28/2023]
Abstract
BACKGROUND Hypothermic machine perfusion (HMP) has become a standard method of preservation for kidneys procured from expanded-criteria donors and donors after cardiac death. There are different systems and approaches to the HMP preservation period, with cold storage prior to HMP sometimes taking several hours. This study evaluated whether the time at which kidneys receive HMP had any influence on the outcomes of kidney transplantation. METHODS In this analysis, patient and graft survival were evaluated over a 1-year post-transplantation period. Patients who received HMP kidneys (n = 379) were divided into 2 groups: those who received kidneys with a cold ischemia time (CIT) prior to HMP <295 minutes (group G1; n = 254) and those who received kidneys with CIT prior to HMP >295 minutes (group G2; n = 125). RESULTS Delayed graft function was observed in 31.8% (81/254) of patients in group G1 vs 46.4% (58/125) of patients in group G2 (P = .007). One-year graft survival was statistically higher in the group G1 (93.2%; 233/254) vs group G2 (86.5%; 105/125, P = .029). Mean 1-year estimated glomerular filtration rate was significantly better in the group G1. CONCLUSIONS In conclusion, introduction of HMP up to 295 minutes from procurement led to better early and 1-year graft results. Kidneys should receive HMP as soon as possible after retrieval, preferably during procurement.
Collapse
Affiliation(s)
- Michal Wszola
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Poland; Foundation of Research and Science Development, Otwock, Poland
| | - Piotr Domagala
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Poland.
| | - Agata Ostaszewska
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Poland; Foundation of Research and Science Development, Otwock, Poland
| | - Lukasz Gorski
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Poland; Foundation of Research and Science Development, Otwock, Poland
| | - Edyta Karpeta
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Poland
| | - Andrzej Berman
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Poland; Foundation of Research and Science Development, Otwock, Poland
| | - Maria Sobol
- Department of Biophysics and Human Physiology, The Medical University of Warsaw, Poland
| | - Magdalena Durlik
- Department of Transplantation Medicine, Nephrology and Internal Medicine, The Medical University of Warsaw, Poland
| | - Andrzej Chmura
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Poland
| | - Artur Kwiatkowski
- Department of General and Transplantation Surgery, The Medical University of Warsaw, Poland; Foundation of Research and Science Development, Otwock, Poland
| |
Collapse
|
6
|
Hamaoui K, Gowers S, Damji S, Rogers M, Leong CL, Hanna G, Darzi A, Boutelle M, Papalois V. Rapid sampling microdialysis as a novel tool for parenchyma assessment during static cold storage and hypothermic machine perfusion in a translational ex vivo porcine kidney model. J Surg Res 2016; 200:332-45. [DOI: 10.1016/j.jss.2015.07.004] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2015] [Revised: 06/24/2015] [Accepted: 07/02/2015] [Indexed: 10/23/2022]
|
7
|
van Heurn LWE, Talbot D, Nicholson ML, Akhtar MZ, Sanchez-Fructuoso AI, Weekers L, Barrou B. Recommendations for donation after circulatory death kidney transplantation in Europe. Transpl Int 2015; 29:780-9. [PMID: 26340168 DOI: 10.1111/tri.12682] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/13/2015] [Revised: 06/19/2015] [Accepted: 08/26/2015] [Indexed: 12/29/2022]
Abstract
Donation after circulatory death (DCD) donors provides an invaluable source for kidneys for transplantation. Over the last decade, we have observed a substantial increase in the number of DCD kidneys, particularly within Europe. We provide an overview of risk factors associated with DCD kidney function and survival and formulate recommendations from the sixth international conference on organ donation in Paris, for best-practice guidelines. A systematic review of the literature was performed using Ovid Medline, Embase and Cochrane databases. Topics are discussed, including donor selection, organ procurement, organ preservation, recipient selection and transplant management.
Collapse
Affiliation(s)
| | - David Talbot
- Department of Liver/Renal Transplant, Freeman Hospital, Newcastle Upon Tyne, UK
| | - Michael L Nicholson
- Department of Surgery, NIHR Cambridge Biomedical Research Centre, Cambridge, UK
| | | | | | - Laurent Weekers
- Department of Nephrology-Dialysis-Transplantation, University of Liège, CHU Sart Tilman, Liège, Belgium
| | - Benoit Barrou
- Department of Urology - Transplantation, GHzu Pitié Salpêtriere, Paris, France
| |
Collapse
|
8
|
Bruinsma BG, Yarmush ML, Uygun K. Organomatics and organometrics: Novel platforms for long-term whole-organ culture. TECHNOLOGY 2014; 2:13. [PMID: 25035864 PMCID: PMC4097862 DOI: 10.1142/s2339547814300029] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Organ culture systems are instrumental as experimental whole-organ models of physiology and disease, as well as preservation modalities facilitating organ replacement therapies such as transplantation. Nevertheless, a coordinated system of machine perfusion components and integrated regulatory control has yet to be fully developed to achieve long-term maintenance of organ function ex vivo. Here we outline current strategies for organ culture, or organomatics, and how these systems can be regulated by means of computational algorithms, or organometrics, to achieve the organ culture platforms anticipated in modern-day biomedicine.
Collapse
|
9
|
Wszola M, Kwiatkowski A, Domagala P, Wirkowska A, Bieniasz M, Diuwe P, Kieszek R, Durlik M, Chmura A. Preservation of Kidneys by Machine Perfusion Influences Gene Expression and May Limit Ischemia/Reperfusion Injury. Prog Transplant 2014; 24:19-26. [DOI: 10.7182/pit2014384] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
Context Machine perfusion improves graft survival. Histopathologic analysis reveals a lower incidence of chronic rejection and interstitial fibrosis in kidneys preserved with machine perfusion. Ischemic/reperfusion injury may help to explain these findings. Objective To assess the activation of genes correlated with ischemic/reperfusion injury in kidneys preserved under different conditions before transplant. Design/Patients Between 2005 and 2006, 69 kidney biopsy specimens were collected and patients were followed up for 5 years after that. Intervention Before transplant, kidneys were preserved with machine perfusion or cold storage. Donors from the machine perfusion and cold storage groups did not differ with regard to age, sex, or hemodynamic status. Recipients were divided into 5 groups: expanded criteria donor–machine perfusion (n = 16), standard criteria donor–machine perfusion (n = 10), expanded criteria donor–cold storage (n = 9), and standard criteria donor–cold storage (n = 27); 7 kidneys were retrieved from living related donors. Main Outcome Measures Biopsies were done 30 minutes after reperfusion. Interleukin-1β, vascular endothelial growth factor, heme oxygenase-1, and hypoxia-inducible factor–1 gene expression levels were analyzed. Results Mean expression levels of hypoxia-inducible factor–1α were significantly higher in the cold storage groups, and lower in the machine perfusion and living-related donor groups. Five-year graft survival was significantly ( P < .05) lower in the expanded criteria donor–cold storage group (66%) than in the standard criteria donor–machine perfusion group (90%). Machine perfusion influences gene expression related to hypoxia during reperfusion and may improve the long-term results of kidney transplant.
Collapse
|
10
|
Post ICJH, de Boon WMI, Heger M, van Wijk ACWA, Kroon J, van Buul JD, van Gulik TM. Endothelial cell preservation at hypothermic to normothermic conditions using clinical and experimental organ preservation solutions. Exp Cell Res 2013; 319:2501-13. [PMID: 23792081 DOI: 10.1016/j.yexcr.2013.05.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2012] [Revised: 04/27/2013] [Accepted: 05/09/2013] [Indexed: 12/29/2022]
Abstract
INTRODUCTION Endothelial barrier function is pivotal for the outcome of organ transplantation. Since hypothermic preservation (gold standard) is associated with cold-induced endothelial damage, endothelial barrier function may benefit from organ preservation at warmer temperatures. We therefore assessed endothelial barrier integrity and viability as function of preservation temperature and perfusion solution, and hypothesized that endothelial cell preservation at subnormothermic conditions using metabolism-supporting solutions constitute optimal preservation conditions. METHODS Human umbilical vein endothelial cells (HUVEC) were preserved at 4-37°C for up to 20 h using Ringer's lactate, histidine-tryptophan-ketoglutarate solution, University of Wisconsin (UW) solution, Polysol, or endothelial cell growth medium (ECGM). Following preservation, the monolayer integrity, metabolic capacity, and ATP content were determined as positive parameters of endothelial cell viability. As negative parameters, apoptosis, necrosis, and cell activation were assayed. A viability index was devised on the basis of these parameters. RESULTS HUVEC viability and barrier integrity was compromised at 4°C regardless of the preservation solution. At temperatures above 20°C, the cells' metabolic demands outweighed the preservation solutions' supporting capacity. Only UW maintained HUVEC viability up to 20°C. Despite high intracellular ATP content, none of the solutions were capable of sufficiently preserving HUVEC above 20°C except for ECGM. CONCLUSION Optimal HUVEC preservation is achieved with UW up to 20°C. Only ECGM maintains HUVEC viability at temperatures above 20°C.
Collapse
Affiliation(s)
- Ivo C J H Post
- Department of Surgery (Surgical Laboratory), Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands
| | | | | | | | | | | | | |
Collapse
|
11
|
Domagała P, Kwiatkowski A, Drozdowski J, Ostrowski K, Wszola M, Diuwe P, Durlik M, Paczek L, Chmura A. Successful outcome of transplant of kidneys recovered from a brain-dead liver transplant recipient: case report. Prog Transplant 2012. [PMID: 23187061 DOI: 10.7182/pit2012953] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
Few reports describing the use of organs donated by transplant recipients have been published. In this case report, kidneys procured from a brain-dead liver recipient were transplanted successfully. A 21-year-old man was referred for liver transplant after an overdose of acetaminophen. The patient's kidney function was initially normal, with proper urine production and normal kidney laboratory parameters. On the third day after admission, the patient's kidney laboratory parameters became elevated and hepatic encephalopathy requiring mechanical ventilation developed. An orthotopic liver transplant was performed the next day. The patient did not recover consciousness, and brain death was diagnosed on the third day after the liver transplant surgery. The maximum serum concentration of creatinine was 5.8 mg/dL (513 μmol/L) before kidney recovery, and urine production was normal. The kidneys were recovered with organ-perfusion support and were preserved by using machine perfusion. The kidneys were transplanted into 2 male recipients. Twelve months after transplant, the recipients remained in good health with satisfactory kidney function. This case demonstrates that transplanting kidneys recovered from liver transplant recipients is possible and beneficial, thus expanding the pool of potential donors.
Collapse
|
12
|
Bon D, Chatauret N, Giraud S, Thuillier R, Favreau F, Hauet T. New strategies to optimize kidney recovery and preservation in transplantation. Nat Rev Nephrol 2012; 8:339-47. [DOI: 10.1038/nrneph.2012.83] [Citation(s) in RCA: 90] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
13
|
Bhangoo RS, Hall IE, Reese PP, Parikh CR. Deceased-donor kidney perfusate and urine biomarkers for kidney allograft outcomes: a systematic review. Nephrol Dial Transplant 2012; 27:3305-14. [PMID: 22498916 DOI: 10.1093/ndt/gfr806] [Citation(s) in RCA: 43] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022] Open
Abstract
BACKGROUND Accurate and reliable assessment of kidney quality before transplantation is needed to predict recipient outcomes and to optimize management and allocation of the allograft. The aim of this study was to systematically review the published literature on biomarkers in two mediums (the perfusate from deceased-donor kidneys receiving machine perfusion and deceased-donor urine) that were evaluated for their possible association with outcomes after kidney transplantation. METHODS We searched the Ovid Medline and Scopus databases using broad keywords related to deceased-donor biomarkers in kidney transplantation (limited to humans and the English language). Studies were included if they involved deceased-donor kidneys, measured perfusate or urine biomarkers and studied a possible relationship between biomarker concentrations and kidney allograft outcomes. Each included article was assessed for methodological quality. RESULTS Of 1430 abstracts screened, 29 studies met the inclusion criteria. Of these, 23 were studies of perfusate (16 biomarkers examined) and 6 were studies of urine (18 biomarkers examined). Only 3 studies (two perfusate) met the criteria of 'good' quality and only 12 were published since 2000. Perfusate lactate dehydrogenase, glutathione-S-transferase (GST) and aspartate transaminase were all found to be significantly associated with delayed graft function in a majority of their respective studies (6/9, 4/6 and 2/2 studies, respectively). Urine neutrophil gelatinase-associated lipocalin, GST, Trolox-equivalent antioxidant capacity and kidney injury molecule-1 were found to be significantly associated with allograft outcomes in single studies that examined diverse end points. CONCLUSION Higher quality studies are needed to investigate modern kidney injury biomarkers, to validate novel biomarkers in larger donor populations and to determine the incremental predictive value of biomarkers over traditional clinical variables.
Collapse
Affiliation(s)
- Ronik S Bhangoo
- Section of Nephrology, Department of Medicine, Yale School of Medicine, New Haven, CT, USA
| | | | | | | |
Collapse
|
14
|
Domagala P, Kwiatkowski A, Perkowska-Ptasinska A, Wszola M, Panufnik L, Paczek L, Durlik M, Chmura A. Assessment of Kidneys Procured From Expanded Criteria Donors Before Transplantation. Transplant Proc 2009; 41:2966-9. [DOI: 10.1016/j.transproceed.2009.08.004] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
15
|
Abstract
PURPOSE OF REVIEW The purpose of this article is to describe the current use of pulsatile kidney perfusion during organ preservation and the effects on kidney allograft outcomes and utilization. RECENT FINDINGS As of spring 2008, there were 75 629 candidates on the kidney waiting list in the USA according to United Network for Organ Sharing data. In 2006, a total of 1815 deceased donor expanded criteria donors kidneys were transplanted, and approximately 80% of those kidneys had cold ischemic time of over 12 h. The utilization of kidney pulsatile perfusion varies extensively throughout the USA with rates of 7-12% in our institution. SUMMARY Data on the use of pulsatile hypothermic perfusion for kidneys during organ preservation are limited and mostly retrospective. Most authors agree that pulsatile perfusion is safe and leads to a decrease in delayed graft function, especially for marginal kidneys from extended criteria or deceased donors. The long-term effects of delayed graft function on graft survival remain to be seen. With the recent large-sampled international prospective randomized trial recently completed, we may see more kidneys pulsatile perfused. This may lead to an increase in the utilization of otherwise discarded kidneys, though these data are difficult to extrapolate.
Collapse
|
16
|
Abstract
Ischemia has been an inevitable event accompanying kidney transplantation. Ischemic changes start with brain death, which is associated with severe hemodynamic disturbances: increasing intracranial pressure results in bradycardia and decreased cardiac output; the Cushing reflex causes tachycardia and increased blood pressure; and after a short period of stabilization, systemic vascular resistance declines with hypotension leading to cardiac arrest. Free radical-mediated injury releases proinflammatory cytokines and activates innate immunity. It has been suggested that all of these changes-the early innate response and the ischemic tissue damage-play roles in the development of adaptive responses, which in turn may lead to an acute font of kidney rejection. Hypothermic kidney storage of various durations before transplantation add to ischemic tissue damage. The final stage of ischemic injury occurs during reperfusion. Reperfusion injury, the effector phase of ischemic injury, develops hours or days after the initial insult. Repair and regeneration processes occur together with cellular apoptosis, autophagy, and necrosis; the fate of the organ depends on whether cell death or regeneration prevails. The whole process has been described as the ischemia-reperfusion (I-R) injury. It has a profound influence on not only the early but also the late function of a transplanted kidney. Prevention of I-R injury should be started before organ recovery by donor pretreatment. The organ shortage has become one of the most important factors limiting extension of deceased donor kidney transplantation worldwide. It has caused increasing use of suboptimal deceased donors (high risk, extended criteria [ECD], marginal donors) and uncontrolled non-heart-beating (NHBD) donors. Kidneys from such donors are exposed to much greater ischemic damage before recovery and show reduced chances for proper early as well as long-term function. Storage of kidneys, especially those recovered from ECD (or NHBD) donors, should use machine perfusion.
Collapse
|
17
|
Kwiatkowski A, Wszola M, Kosieradzki M, Danielewicz R, Ostrowski K, Domagala P, Lisik W, Nosek R, Fesolowicz S, Trzebicki J, Durlik M, Paczek L, Chmura A, Rowinski W. Machine perfusion preservation improves renal allograft survival. Am J Transplant 2007; 7:1942-7. [PMID: 17617857 DOI: 10.1111/j.1600-6143.2007.01877.x] [Citation(s) in RCA: 66] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
UNLABELLED Machine perfusion (MP) has been used as the kidney preservation method in our center for over 10 years. The first, small (n = 74) prospective, single-blinded randomized study comparing MP and Cold Storage (CS) showed that the incidence of delayed graft function was higher after CS. There have been no reports in the literature on the effect of storage modality on long-term function of renal allografts. This paper presents an analysis of long-term results of renal transplantation in 415 patients operated on between 1994 and 1999. Of those, 227 kidneys were MP-stored prior to KTx. The control group consisted of 188 CS kidney transplants. Kidneys were not randomized to MP or to CS. Donor demographics, medical and biochemical data, cold ischemia time, HLA match and recipient data were collected. Standard triple-drug immunosuppression was administered to both groups. Mortality, graft survival and incidence of return to hemodialysis treatment were analyzed. Despite longer cold ischemia time and poorer donor hemodynamics in MP group, 5-year Kaplan-Meier graft survival was better in MP-stored than in CS-stored kidneys (68.2% vs. 54.2%, p = 0.02). CONCLUSION In this nonrandomized analysis, kidney storage by MP improved graft survival and reduced the number of patients who returned to dialysis.
Collapse
Affiliation(s)
- A Kwiatkowski
- Department of General and Transplantation Surgery, Warsaw Medical University, Poland
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Fuller BJ, Lee CY. Hypothermic perfusion preservation: the future of organ preservation revisited? Cryobiology 2007; 54:129-45. [PMID: 17362905 DOI: 10.1016/j.cryobiol.2007.01.003] [Citation(s) in RCA: 71] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2006] [Revised: 01/11/2007] [Accepted: 01/11/2007] [Indexed: 12/24/2022]
Abstract
Hypothermic perfusion preservation (HPP) was an integral step in the development of early clinical transplantation programmes, and considerable progress was made in understanding the basic principles underlying the technique. In subsequent years, the development of better preservation solutions for cold hypoxic storage, along with pragmatic choices made on grounds of costs and logistics, saw a fall in the application of HPP. More recently, the acute shortage of suitable organ donors and the inevitable pressure to use organs from sub-optimal (or expanded criteria) donors, has forced a re-evaluation of HPP, and the development of a new generation of HPP machines and associated perfusion solutions. This review sets out the historical development of HPP across the range of organs in which the method was originally investigated, describes the biological benefits and drawbacks associated with HPP, and sets out the most recent literature on the topic (including comments on the interest in use of higher temperatures in organ perfusion).
Collapse
Affiliation(s)
- Barry J Fuller
- University Department of Surgery and Liver Transplant Unit, Royal Free and University College Medical School, Hampstead, London NW3 2QG, UK.
| | | |
Collapse
|
19
|
Schold JD, Kaplan B, Howard RJ, Reed AI, Foley DP, Meier-Kriesche HU. Are we frozen in time? Analysis of the utilization and efficacy of pulsatile perfusion in renal transplantation. Am J Transplant 2005; 5:1681-8. [PMID: 15943626 DOI: 10.1111/j.1600-6143.2005.00910.x] [Citation(s) in RCA: 136] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/25/2023]
Abstract
Preservation techniques are crucial to deceased donor kidney transplantation (DDTx), but the efficacy of pulsatile perfusion (PP) versus cold storage (CS) remains uncertain. We describe patterns of PP use and explore four fundamental questions. What kidneys are selected for PP? How does PP affect utilization of donated kidneys? What effect does PP have on outcomes? When does PP appear to be most efficacious? We examined rates of PP in DDTx in the United States from 1994 to 2003. We generated models for organ utilization, delayed graft function (DGF) and for the use of PP. We analyzed the long-term effect of PP with multivariate Cox models. The utilization rates for non-expanded criteria donors (ECDs) were similar by storage type, but for ECDs there was a significantly higher utilization rate with PP (70% with PP vs. 59% with CS, p < 0.001). Use of PP was widely variable across transplant centers. DGF rates were significantly lower with PP (27.6% vs. 19.6%). PP was associated with a mild benefit on death censored graft survival (adjusted hazard ratio = 0.88, 95% CI 0.85-0.91). Reduced DGF and significantly lower discard rates of ECDs associated with PP suggest an important utility of PP in renal transplantation. Additional evidence of improvement in graft survival, particularly in more recent years, provides further encouraging evidence for the use of PP.
Collapse
Affiliation(s)
- Jesse D Schold
- Department of Medicine, University of Florida, Gainesville, FL, USA.
| | | | | | | | | | | |
Collapse
|