1
|
Young ER, Martin C, Ribaudo J, Xia X, Moritz WR, Madira S, Zayed MA, Sacks JM, Li X. Surface Modification of PEEKs with Cyclic Peptides to Support Endothelialization and Antithrombogenicity. MATERIALS TODAY. COMMUNICATIONS 2024; 39:108664. [PMID: 38618226 PMCID: PMC11008579 DOI: 10.1016/j.mtcomm.2024.108664] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/16/2024]
Abstract
Synthetic polymers are often utilized in the creation of vascular devices, and need to possess specific qualities to prevent thrombosis. Traditional strategies for this include surface modification of vascular devices through covalent attachment of substrates such as heparin, antiplatelet agents, thrombolytic agents, or hydrophilic polymers. One promising prosthetic material is polyether ether ketone (PEEK), which is utilized in various FDA-approved medical devices, including vascular and endovascular prostheses. We hypothesized that surface modification of biologically inert PEEK can help improve its endothelial cell affinity and reduce its thrombogenic potential. To evaluate this, we developed an effective surface-modification approach with unique cyclic peptides, such as CCHGGVRLYC and CCREDVC. We treated the PEEK surface with ammonia plasma, which introduced amine groups onto the PEEK surface. Subsequently, we were able to conjugate these peptides to the plasma-modified PEEKs. We observed that cyclic CCHGGVRLYC conjugated on prosthetic PEEK not only supported endothelialization, but minimized platelet adhesion and activation. This technology can be potentially applied for in vivo vascular and endovascular protheses to enhance their utility and patency.
Collapse
Affiliation(s)
- Emma R. Young
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine
| | - Cameron Martin
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine
| | - Joseph Ribaudo
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine
| | - Xiaochao Xia
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine
| | - William R. Moritz
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine
| | - Sarah Madira
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine
| | - Mohamed A. Zayed
- Section of Vascular Surgery, Washington University School of Medicine
- Division of Molecular Cell Biology, Washington University School of Medicine
- Department of Biomedical Engineering, McKelvey School of Engineering, Washington University in St. Louis
- St. Louis Veterans Affairs Health Care System, St. Louis, MO
| | - Justin M. Sacks
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine
| | - Xiaowei Li
- Division of Plastic and Reconstructive Surgery, Washington University School of Medicine
| |
Collapse
|
2
|
Mordzińska-Rak A, Szałapata K, Wydrych J, Gagoś M, Jarosz-Wilkołazka A. Attachment of Proteolytic Enzyme Inhibitors to Vascular Prosthesis-An Analysis of Binding and Antimicrobial Properties. Molecules 2024; 29:935. [PMID: 38474448 DOI: 10.3390/molecules29050935] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/12/2023] [Revised: 02/16/2024] [Accepted: 02/19/2024] [Indexed: 03/14/2024] Open
Abstract
Prosthetic infections are associated with high morbidity, mortality, and relapse rates, making them still a serious problem for implantology. Staphylococcus aureus is one of the most common bacterial pathogens causing prosthetic infections. In response to the increasing rate of bacterial resistance to commonly used antibiotics, this work proposes a method for combating pathogenic microorganisms by modifying the surfaces of synthetic polymeric biomaterials using proteolytic enzyme inhibitors (serine protease inhibitors-4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride and puromycin). While using techniques based on the immobilization of biologically active molecules, it is important to monitor the changes occurring on the surface of the modified biomaterial, where spectroscopic techniques (e.g., FTIR) are ideal. ATR-FTIR measurements demonstrated that the immobilization of both inhibitors caused large structural changes on the surface of the tested vascular prostheses (polyester or polytetrafluoroethylene) and showed that they were covalently bonded to the surfaces of the biomaterials. Next, the bactericidal and antibiofilm activities of the tested serine protease inhibitors were determined using the CLSM microscopic technique with fluorescent staining. During LIVE/DEAD analyses, a significant decrease in the formation of Staphylococcus aureus biofilm after exposure to selected concentrations of native inhibitors (0.02-0.06 mg/mL for puromycin and 0.2-1 mg/mL for 4-(2-aminoethyl)benzenesulfonyl fluoride hydrochloride) was demonstrated.
Collapse
Affiliation(s)
- Aleksandra Mordzińska-Rak
- Department of Biochemistry and Biotechnology, Institute of Biological Science, Maria Curie-Skłodowska University, Akademicka 19, 20-031 Lublin, Poland
| | - Katarzyna Szałapata
- Department of Biochemistry and Biotechnology, Institute of Biological Science, Maria Curie-Skłodowska University, Akademicka 19, 20-031 Lublin, Poland
| | - Jerzy Wydrych
- Institute of Biological Sciences, Maria Curie-Skłodowska University, Akademicka 19, 20-031 Lublin, Poland
| | - Mariusz Gagoś
- Department of Cell Biology, Institute of Biological Science, Maria Curie-Skłodowska University, Akademicka 19, 20-031 Lublin, Poland
| | - Anna Jarosz-Wilkołazka
- Department of Biochemistry and Biotechnology, Institute of Biological Science, Maria Curie-Skłodowska University, Akademicka 19, 20-031 Lublin, Poland
| |
Collapse
|
3
|
Mahara A, Shirai M, Soni R, Le HT, Shimizu K, Hirano Y, Yamaoka T. Vascular tissue reconstruction by monocyte subpopulations on small-diameter acellular grafts via integrin activation. Mater Today Bio 2023; 23:100847. [PMID: 37953756 PMCID: PMC10632538 DOI: 10.1016/j.mtbio.2023.100847] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2023] [Revised: 10/17/2023] [Accepted: 10/26/2023] [Indexed: 11/14/2023] Open
Abstract
Although the clinical application of cell-free tissue-engineered vascular grafts (TEVGs) has been proposed, vascular tissue regeneration mechanisms have not been fully clarified. Here, we report that monocyte subpopulations reconstruct vascular-like tissues through integrin signaling. An Arg-Glu-Asp-Val peptide-modified acellular long-bypass graft was used as the TEVG, and tissue regeneration in the graft was evaluated using a cardiopulmonary pump system and porcine transplantation model. In 1 day, the luminal surface of the graft was covered with cells that expressed CD163, CD14, and CD16, which represented the monocyte subpopulation, and they exhibited proliferative and migratory abilities. RNA sequencing showed that captured cells had an immune-related phenotype similar to that of monocytes and strongly expressed cell adhesion-related genes. In vitro angiogenesis assay showed that tube formation of the captured cells occurred via integrin signal activation. After medium- and long-term graft transplantation, the captured cells infiltrated the tunica media layer and constructed vascular with a CD31/CD105-positive layer and an αSMA-positive structure after 3 months. This finding, including multiple early-time observations provides clear evidence that blood-circulating monocytes are directly involved in vascular remodeling.
Collapse
Affiliation(s)
- Atsushi Mahara
- Department of Biomedical Engineering, National Cerebral and Cardiovascular Center Research Institute, Kishibe Shimmachi, Suita Osaka, 564-8565, Japan
| | - Manabu Shirai
- Omics Research Center, National Cerebral and Cardiovascular Center Research Institute, Kishibe Shimmachi, Suita Osaka, 564-8565, Japan
| | - Raghav Soni
- Department of Biomedical Engineering, National Cerebral and Cardiovascular Center Research Institute, Kishibe Shimmachi, Suita Osaka, 564-8565, Japan
| | - Hue Thi Le
- Department of Biomedical Engineering, National Cerebral and Cardiovascular Center Research Institute, Kishibe Shimmachi, Suita Osaka, 564-8565, Japan
| | - Kaito Shimizu
- Faculty of Chemistry, Materials and Bioengineering, Kansai University, 3-3-35 Yamatecho, Suita, Osaka, 565-8680, Japan
| | - Yoshiaki Hirano
- Faculty of Chemistry, Materials and Bioengineering, Kansai University, 3-3-35 Yamatecho, Suita, Osaka, 565-8680, Japan
| | - Tetsuji Yamaoka
- Department of Biomedical Engineering, National Cerebral and Cardiovascular Center Research Institute, Kishibe Shimmachi, Suita Osaka, 564-8565, Japan
| |
Collapse
|
4
|
Taneda H, Yamada NL, Nemoto F, Minagawa Y, Matsuno H, Tanaka K. Modification of a Polymer Surface by Partial Swelling Using Nonsolvents. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2021; 37:14941-14949. [PMID: 34904431 DOI: 10.1021/acs.langmuir.1c02852] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Surface modification without changing the physical properties in the bulk is of pivotal importance for the development of polymers as devices. We recently proposed a simple surface functionalization method for polymer films by partial swelling using a nonsolvent and demonstrated the incorporation of poly(2-methoxyethyl acrylate) (PMEA), which has an excellent antibiofouling ability, only into the outermost region of a poly(methyl methacrylate) (PMMA) film. We here extend this technology to another versatile polymer, polystyrene (PS). In this case, PS and PMEA have different solubility parameters making it difficult to select a suitable solvent, which is a nonsolvent for PS and a good solvent for PMEA, unlike the combination of PMMA with PMEA. Thus, such a solvent was first sought by examining the swelling behavior of PS films in contact with various alcohols. Once a mixed solvent of methanol/1-butanol (50/50 (v/v)) was chosen, PMEA chains could be successfully incorporated at the outermost region of the PS film. Atomic force microscopy in conjunction with neutron reflectivity revealed that chains of PMEA incorporated in the PS surface region were well swollen in water. This leads to an excellent ability to suppress the adhesion of platelets on the PS film.
Collapse
Affiliation(s)
- Hidenobu Taneda
- Department of Applied Chemistry, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Norifumi L Yamada
- Neutron Science Laboratory, High Energy Accelerator Research Organization, 203-1 Shirakata, Tokai, Naka-gun, Ibaraki 319-1106, Japan
| | - Fumiya Nemoto
- Neutron Science Laboratory, High Energy Accelerator Research Organization, 203-1 Shirakata, Tokai, Naka-gun, Ibaraki 319-1106, Japan
| | - Yasuhisa Minagawa
- Sumitomo Rubber Industries, Ltd., 2-1-1 Tsutsui-cho, Chuo-ku, Kobe 651-0071, Japan
| | - Hisao Matsuno
- Department of Applied Chemistry, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
- Center for Polymer Interface and Molecular Adhesion Science, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| | - Keiji Tanaka
- Department of Applied Chemistry, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
- Center for Polymer Interface and Molecular Adhesion Science, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
| |
Collapse
|
5
|
Vesel A, Zaplotnik R, Primc G, Mozetič M, Katan T, Kargl R, Mohan T, Kleinschek KS. Rapid Functionalization of Polytetrafluorethylene (PTFE) Surfaces with Nitrogen Functional Groups. Polymers (Basel) 2021; 13:4301. [PMID: 34960856 PMCID: PMC8708819 DOI: 10.3390/polym13244301] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/03/2021] [Accepted: 12/06/2021] [Indexed: 11/16/2022] Open
Abstract
The biocompatibility of body implants made from polytetrafluoroethylene (PTFE) is inadequate; therefore, the surface should be grafted with biocompatible molecules. Because PTFE is an inert polymer, the adhesion of the biocompatible film may not be appropriate. Therefore, the PFTE surface should be modified to enable better adhesion, preferably by functionalization with amino groups. A two-step process for functionalization of PTFE surface is described. The first step employs inductively coupled hydrogen plasma in the H-mode and the second ammonia plasma. The evolution of functional groups upon treatment with ammonia plasma in different modes is presented. The surface is saturated with nitrogen groups within a second if ammonia plasma is sustained in the H-mode at the pressure of 35 Pa and forward power of 200 W. The nitrogen-rich surface film persists for several seconds, while prolonged treatment causes etching. The etching is suppressed but not eliminated using pulsed ammonia plasma at 35 Pa and 200 W. Ammonia plasma in the E-mode at the same pressure, but forward power of 25 W, causes more gradual functionalization and etching was not observed even at prolonged treatments up to 100 s. Detailed investigation of the XPS spectra enabled revealing the surface kinetics for all three cases.
Collapse
Affiliation(s)
- Alenka Vesel
- Department of Surface Engineering, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (R.Z.); (G.P.); (M.M.)
| | - Rok Zaplotnik
- Department of Surface Engineering, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (R.Z.); (G.P.); (M.M.)
| | - Gregor Primc
- Department of Surface Engineering, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (R.Z.); (G.P.); (M.M.)
| | - Miran Mozetič
- Department of Surface Engineering, Jožef Stefan Institute, Jamova 39, 1000 Ljubljana, Slovenia; (R.Z.); (G.P.); (M.M.)
| | - Tadeja Katan
- Institute for Chemistry and Technology of Biobased Systems, Graz University of Technology, Stremayrgasse 9, 8010 Graz, Austria; (T.K.); (R.K.); (T.M.); (K.S.K.)
| | - Rupert Kargl
- Institute for Chemistry and Technology of Biobased Systems, Graz University of Technology, Stremayrgasse 9, 8010 Graz, Austria; (T.K.); (R.K.); (T.M.); (K.S.K.)
| | - Tamilselvan Mohan
- Institute for Chemistry and Technology of Biobased Systems, Graz University of Technology, Stremayrgasse 9, 8010 Graz, Austria; (T.K.); (R.K.); (T.M.); (K.S.K.)
| | - Karin Stana Kleinschek
- Institute for Chemistry and Technology of Biobased Systems, Graz University of Technology, Stremayrgasse 9, 8010 Graz, Austria; (T.K.); (R.K.); (T.M.); (K.S.K.)
| |
Collapse
|
6
|
Haque ST, Saha SK, Haque ME, Biswas N. Nanotechnology-based therapeutic applications: in vitro and in vivo clinical studies for diabetic wound healing. Biomater Sci 2021; 9:7705-7747. [PMID: 34709244 DOI: 10.1039/d1bm01211h] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Diabetic wounds often indicate chronic complications that are difficult to treat. Unfortunately, existing conventional treatment modalities often cause unpremeditated side effects, given the need to develop alternative therapeutic phenotypes that are safe or have minimal side effects and risks. Nanotechnology-based platforms, including nanotherapeutics, nanoparticles (NPs), nanofibers, nanohydrogels, and nanoscaffolds, have garnered attention for their groundbreaking potential to decipher the biological environment and offer personalized treatment methods for wound healing. These nanotechnology-based platforms can successfully overcome the impediments posed by drug toxicity, existing treatment modalities, and the physiology and complexity of the wound sites. Furthermore, studies have shown that they play an essential role in influencing angiogenesis, collagen production, and extracellular matrix (ECM) synthesis, which are integral in skin repair mechanisms. In this review, we emphasized the importance of various nanotechnology-based platforms for healing diabetic wounds and report on the innovative preclinical and clinical outcomes of different nanotechnology-based platforms. This review also outlined the limitations of existing conventional treatment modalities and summarized the physiology of acute and chronic diabetic wounds.
Collapse
Affiliation(s)
- Sheikh Tanzina Haque
- Jeffrey Cheah School of Medicine and Health Sciences, Monash University Malaysia, Jalan Lagoon Selatan, Bandar Sunway, 47500 Subang Jaya, Selangor, Malaysia.
| | - Subbroto Kumar Saha
- Department of Biochemistry and Molecular Medicine, University of California, Davis School of Medicine, Sacramento, CA 95817, USA.,Department of Stem Cell and Regenerative Biotechnology, Incurable Disease Animal Model & Stem Cell Institute (IDASI), Konkuk University, 120 Neugdong-ro, Gwangjin-gu, Seoul 05029, Korea.
| | - Md Enamul Haque
- Department of Biochemistry and Molecular Biology, University of Dhaka, Dhaka 1000, Bangladesh.
| | - Nirupam Biswas
- Department of Surgery, Indiana University School of Medicine, Indianapolis, IN-46202, USA.,Department of Immunology and Microbial Diseases, Albany Medical College, Albany, NY-12208, USA.
| |
Collapse
|
7
|
Zhen L, Creason SA, Simonovsky FI, Snyder JM, Lindhartsen SL, Mecwan MM, Johnson BW, Himmelfarb J, Ratner BD. Precision-porous polyurethane elastomers engineered for application in pro-healing vascular grafts: Synthesis, fabrication and detailed biocompatibility assessment. Biomaterials 2021; 279:121174. [PMID: 34715636 DOI: 10.1016/j.biomaterials.2021.121174] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 08/16/2021] [Indexed: 01/22/2023]
Abstract
Unmet needs for small diameter, non-biologic vascular grafts and the less-than-ideal performance of medium diameter grafts suggest opportunities for major improvements. Biomaterials that are mechanically matched to native blood vessels, reduce the foreign body capsule (FBC) and demonstrate improved integration and healing are expected to improve graft performance. In this study, we developed biostable, crosslinked polyurethane formulations and used them to fabricate scaffolds with precision-engineered 40 μm pores. We matched the scaffold mechanical properties with those of native blood vessels by optimizing the polyurethane compositions. We hypothesized that such scaffolds promote healing and mitigate the FBC. To test our hypothesis, polyurethanes with 40 μm pores, 100 μm pores, and non-porous slabs were implanted subcutaneously in mice for 3 weeks, and then were examined histologically. Our results show that 40 μm porous scaffolds elicit the highest level of angiogenesis, cellularization, and the least severe foreign body capsule (based on a refined assessment method). This study presents the first biomaterial with tuned mechanical properties and a precision engineered porous structure optimized for healing, thus can be ideal for pro-healing vascular grafts and in situ vascular engineering. In addition, these scaffolds may have wide applications in tissue engineering, drug delivery, and implantable device.
Collapse
Affiliation(s)
- Le Zhen
- Department of Chemical Engineering, University of Washington, Seattle, WA, 98195, USA; Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Sharon A Creason
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Felix I Simonovsky
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Jessica M Snyder
- Department of Comparative Medicine, University of Washington, Seattle, WA, 98195, USA
| | - Sarah L Lindhartsen
- Histology and Imaging Core, University of Washington, Seattle, WA, 98195, USA
| | - Marvin M Mecwan
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA
| | - Brian W Johnson
- Histology and Imaging Core, University of Washington, Seattle, WA, 98195, USA
| | - Jonathan Himmelfarb
- Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA; Department of Medicine, Division of Nephrology, University of Washington, Seattle, WA, 98195, USA; Kidney Research Institute, Seattle, WA, 98104, USA; Center for Dialysis Innovation, University of Washington, WA, 98195, USA
| | - Buddy D Ratner
- Department of Chemical Engineering, University of Washington, Seattle, WA, 98195, USA; Department of Bioengineering, University of Washington, Seattle, WA, 98195, USA; Center for Dialysis Innovation, University of Washington, WA, 98195, USA.
| |
Collapse
|
8
|
Wang L, Jiao L, Pang S, Yan P, Wang X, Qiu T. The Development of Design and Manufacture Techniques for Bioresorbable Coronary Artery Stents. MICROMACHINES 2021; 12:mi12080990. [PMID: 34442612 PMCID: PMC8398368 DOI: 10.3390/mi12080990] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/30/2021] [Revised: 08/18/2021] [Accepted: 08/18/2021] [Indexed: 02/02/2023]
Abstract
Coronary artery disease (CAD) is the leading killer of humans worldwide. Bioresorbable polymeric stents have attracted a great deal of interest because they can treat CAD without producing long-term complications. Bioresorbable polymeric stents (BMSs) have undergone a sustainable revolution in terms of material processing, mechanical performance, biodegradability and manufacture techniques. Biodegradable polymers and copolymers have been widely studied as potential material candidates for bioresorbable stents. It is a great challenge to find a reasonable balance between the mechanical properties and degradation behavior of bioresorbable polymeric stents. Surface modification and drug-coating methods are generally used to improve biocompatibility and drug loading performance, which are decisive factors for the safety and efficacy of bioresorbable stents. Traditional stent manufacture techniques include etching, micro-electro discharge machining, electroforming, die-casting and laser cutting. The rapid development of 3D printing has brought continuous innovation and the wide application of biodegradable materials, which provides a novel technique for the additive manufacture of bioresorbable stents. This review aims to describe the problems regarding and the achievements of biodegradable stents from their birth to the present and discuss potential difficulties and challenges in the future.
Collapse
Affiliation(s)
- Liang Wang
- School of Mechanical Engineering, Beijing Institute of Technology, No. 5 Zhongguancun South Street, Haidian District, Beijing 100081, China; (L.W.); (S.P.)
| | - Li Jiao
- Key Laboratory of Fundamental Science for Advanced Machining Beijing Institute of Technology, No. 5 Zhongguancun South Street, Haidian District, Beijing 100081, China; (L.J.); (P.Y.); (X.W.)
| | - Shuoshuo Pang
- School of Mechanical Engineering, Beijing Institute of Technology, No. 5 Zhongguancun South Street, Haidian District, Beijing 100081, China; (L.W.); (S.P.)
| | - Pei Yan
- Key Laboratory of Fundamental Science for Advanced Machining Beijing Institute of Technology, No. 5 Zhongguancun South Street, Haidian District, Beijing 100081, China; (L.J.); (P.Y.); (X.W.)
| | - Xibin Wang
- Key Laboratory of Fundamental Science for Advanced Machining Beijing Institute of Technology, No. 5 Zhongguancun South Street, Haidian District, Beijing 100081, China; (L.J.); (P.Y.); (X.W.)
| | - Tianyang Qiu
- Key Laboratory of Fundamental Science for Advanced Machining Beijing Institute of Technology, No. 5 Zhongguancun South Street, Haidian District, Beijing 100081, China; (L.J.); (P.Y.); (X.W.)
- Correspondence:
| |
Collapse
|
9
|
Lomovskoy VA, Suvorova OV, Abaturova NA, Lomovskaya NY, Shatokhina SA, Kulyukhin SA. Influence of Small Doses of Electron Beam Radiation on Relaxation Microheterogeneity of Segmental Mobility in Polyvinyl Alcohol. HIGH ENERGY CHEMISTRY 2021. [DOI: 10.1134/s0018143921030073] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
10
|
Gilman AB, Piskarev MS, Kuznetsov AA. Modification of Polyethylene Terephthalate by Low-Temperature Plasma for Use in Medicine and Biology. HIGH ENERGY CHEMISTRY 2021. [DOI: 10.1134/s0018143921020065] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
|
11
|
Clauser JC, Maas J, Arens J, Schmitz-Rode T, Steinseifer U, Berkels B. Hemocompatibility Evaluation of Biomaterials-The Crucial Impact of Analyzed Area. ACS Biomater Sci Eng 2021; 7:553-561. [PMID: 33481566 DOI: 10.1021/acsbiomaterials.0c01589] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The hemocompatibility of blood-contacting medical devices remains one of the major challenges in medical device development. A common tool for the analysis of adherent and activated platelets on materials following in vitro tests is microscopy. Currently, most researchers develop their own routines, resulting in numerous different methods that are applied. The majority of those (semi-)manual methods analyze only a very small fraction of the material surface (<1%), which neglects the inhomogeneity of platelet distribution and makes results hardly comparable. Within this study, we examined the relation between the fraction of analyzed sample area and the platelet adhesion result. By means of image segmentation and machine learning algorithms, 103 100 microscopy images were analyzed automatically. We discovered a crucial impact of the analyzed surface fraction and thus a misrepresentation of a surface's platelet adhesion unless up to 40% of the sample surface is analyzed. These findings underline the necessity of standardization in the field of in vitro hemocompatibility tests and analyses in particular and provide a first basis to make future tests more reliable and comparable.
Collapse
Affiliation(s)
- Johanna C Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Judith Maas
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany.,Chair in Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Benjamin Berkels
- AICES Graduate School, RWTH Aachen University, Schinkelstr. 2, 52062 Aachen, Germany.,Institute for Geometry and Practical Mathematics, RWTH Aachen University, Templergraben 55, 52056 Aachen, Germany
| |
Collapse
|
12
|
Mallis P, Kostakis A, Stavropoulos-Giokas C, Michalopoulos E. Future Perspectives in Small-Diameter Vascular Graft Engineering. Bioengineering (Basel) 2020; 7:E160. [PMID: 33321830 PMCID: PMC7763104 DOI: 10.3390/bioengineering7040160] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2020] [Revised: 12/04/2020] [Accepted: 12/09/2020] [Indexed: 02/07/2023] Open
Abstract
The increased demands of small-diameter vascular grafts (SDVGs) globally has forced the scientific society to explore alternative strategies utilizing the tissue engineering approaches. Cardiovascular disease (CVD) comprises one of the most lethal groups of non-communicable disorders worldwide. It has been estimated that in Europe, the healthcare cost for the administration of CVD is more than 169 billion €. Common manifestations involve the narrowing or occlusion of blood vessels. The replacement of damaged vessels with autologous grafts represents one of the applied therapeutic approaches in CVD. However, significant drawbacks are accompanying the above procedure; therefore, the exploration of alternative vessel sources must be performed. Engineered SDVGs can be produced through the utilization of non-degradable/degradable and naturally derived materials. Decellularized vessels represent also an alternative valuable source for the development of SDVGs. In this review, a great number of SDVG engineering approaches will be highlighted. Importantly, the state-of-the-art methodologies, which are currently employed, will be comprehensively presented. A discussion summarizing the key marks and the future perspectives of SDVG engineering will be included in this review. Taking into consideration the increased number of patients with CVD, SDVG engineering may assist significantly in cardiovascular reconstructive surgery and, therefore, the overall improvement of patients' life.
Collapse
Affiliation(s)
- Panagiotis Mallis
- Hellenic Cord Blood Bank, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (C.S.-G.); (E.M.)
| | - Alkiviadis Kostakis
- Center of Experimental Surgery and Translational Research, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece;
| | - Catherine Stavropoulos-Giokas
- Hellenic Cord Blood Bank, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (C.S.-G.); (E.M.)
| | - Efstathios Michalopoulos
- Hellenic Cord Blood Bank, Biomedical Research Foundation Academy of Athens, 4 Soranou Ephessiou Street, 115 27 Athens, Greece; (C.S.-G.); (E.M.)
| |
Collapse
|
13
|
Badv M, Bayat F, Weitz JI, Didar TF. Single and multi-functional coating strategies for enhancing the biocompatibility and tissue integration of blood-contacting medical implants. Biomaterials 2020; 258:120291. [PMID: 32798745 DOI: 10.1016/j.biomaterials.2020.120291] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2020] [Revised: 06/27/2020] [Accepted: 08/01/2020] [Indexed: 12/27/2022]
Abstract
Device-associated clot formation and poor tissue integration are ongoing problems with permanent and temporary implantable medical devices. These complications lead to increased rates of mortality and morbidity and impose a burden on healthcare systems. In this review, we outline the current approaches for developing single and multi-functional surface coating techniques that aim to circumvent the limitations associated with existing blood-contacting medical devices. We focus on surface coatings that possess dual hemocompatibility and biofunctionality features and discuss their advantages and shortcomings to providing a biocompatible and biodynamic interface between the medical implant and blood. Lastly, we outline the newly developed surface modification techniques that use lubricant-infused coatings and discuss their unique potential and limitations in mitigating medical device-associated complications.
Collapse
Affiliation(s)
- Maryam Badv
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada; Department of Mechanical Engineering, McMaster University, Hamilton, Ontario, Canada
| | - Fereshteh Bayat
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada
| | - Jeffrey I Weitz
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada; Thrombosis & Atherosclerosis Research Institute (TaARI), Hamilton, Ontario, Canada; Department of Medicine, McMaster University, Hamilton, Ontario, Canada; Department of Biochemistry and Biomedical Sciences, McMaster University, Hamilton, Ontario, Canada
| | - Tohid F Didar
- School of Biomedical Engineering, McMaster University, Hamilton, Ontario, Canada; Department of Mechanical Engineering, McMaster University, Hamilton, Ontario, Canada; Institute for Infectious Disease Research (IIDR), McMaster University, Hamilton, Ontario, Canada.
| |
Collapse
|
14
|
Grainger DW. Fluorinated Biomaterials. Biomater Sci 2020. [DOI: 10.1016/b978-0-12-816137-1.00012-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
15
|
Maitz MF, Martins MCL, Grabow N, Matschegewski C, Huang N, Chaikof EL, Barbosa MA, Werner C, Sperling C. The blood compatibility challenge. Part 4: Surface modification for hemocompatible materials: Passive and active approaches to guide blood-material interactions. Acta Biomater 2019; 94:33-43. [PMID: 31226481 DOI: 10.1016/j.actbio.2019.06.019] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2019] [Revised: 05/29/2019] [Accepted: 06/13/2019] [Indexed: 12/22/2022]
Abstract
Biomedical devices in the blood flow disturb the fine-tuned balance of pro- and anti-coagulant factors in blood and vessel wall. Numerous technologies have been suggested to reduce coagulant and inflammatory responses of the body towards the device material, ranging from camouflage effects to permanent activity and further to a responsive interaction with the host systems. However, not all types of modification are suitable for all types of medical products. This review has a focus on application-oriented considerations of hemocompatible surface fittings. Thus, passive versus bioactive modifications are discussed along with the control of protein adsorption, stability of the immobilization, and the type of bioactive substance, biological or synthetic. Further considerations are related to the target system, whether enzymes or cells should be addressed in arterial or venous system, or whether the blood vessel wall is addressed. Recent developments like feedback controlled or self-renewing systems for drug release or addressing cellular regulation pathways of blood platelets and endothelial cells are paradigms for a generation of blood contacting devices, which are hemocompatible by cooperation with the host system. STATEMENT OF SIGNIFICANCE: This paper is part 4 of a series of 4 reviews discussing the problem of biomaterial associated thrombogenicity. The objective was to highlight features of broad agreement and provide commentary on those aspects of the problem that were subject to dispute. We hope that future investigators will update these reviews as new scholarship resolves the uncertainties of today.
Collapse
Affiliation(s)
- Manfred F Maitz
- Institute Biofunctional Polymer Materials, Max Bergmann Center of Biomaterials, Leibniz-Institut für Polymerforschung Dresden e.V., Dresden, Germany; Key Laboratory of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China.
| | - M Cristina L Martins
- i3S, Instituto de Investigação e Inovação em Saúde, Portugal; INEB, Instituto de Engenharia Biomédica, Rua Alfredo Allen, 208, 4200-135 Porto, Portugal; ICBAS, Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, Portugal
| | - Niels Grabow
- Institut für Biomedizinische Technik, Universitätsmedizin Rostock, Friedrich-Barnewitz-Str. 4, 18119 Rostock, Germany
| | - Claudia Matschegewski
- Institut für Biomedizinische Technik, Universitätsmedizin Rostock, Friedrich-Barnewitz-Str. 4, 18119 Rostock, Germany; Institute for ImplantTechnology and Biomaterials (IIB) e.V., Friedrich-Barnewitz-Str. 4, 18119 Rostock, Germany
| | - Nan Huang
- Key Laboratory of Advanced Technology for Materials of Education Ministry, School of Materials Science and Engineering, Southwest Jiaotong University, Chengdu 610031, China
| | - Elliot L Chaikof
- Department of Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 330 Brookline Avenue, Boston, MA 02115, United States; Wyss Institute for Biologically Inspired Engineering at Harvard University, 3 Blackfan Circle, Boston, MA 02115, United States; Harvard-MIT Division of Health Sciences and Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, United States
| | - Mário A Barbosa
- i3S, Instituto de Investigação e Inovação em Saúde, Portugal; INEB, Instituto de Engenharia Biomédica, Rua Alfredo Allen, 208, 4200-135 Porto, Portugal; ICBAS, Instituto de Ciências Biomédicas Abel Salazar, Universidade do Porto, Porto, Portugal
| | - Carsten Werner
- Institute Biofunctional Polymer Materials, Max Bergmann Center of Biomaterials, Leibniz-Institut für Polymerforschung Dresden e.V., Dresden, Germany
| | - Claudia Sperling
- Institute Biofunctional Polymer Materials, Max Bergmann Center of Biomaterials, Leibniz-Institut für Polymerforschung Dresden e.V., Dresden, Germany
| |
Collapse
|
16
|
Mi HY, Jing X, Thomsom JA, Turng LS. Promoting Endothelial Cell Affinity and Antithrombogenicity of Polytetrafluoroethylene (PTFE) by Mussel-Inspired Modification and RGD/Heparin Grafting. J Mater Chem B 2018; 6:3475-3485. [PMID: 30455952 PMCID: PMC6238965 DOI: 10.1039/c8tb00654g] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
When used as small-diameter vascular grafts (SDVGs), synthetic biomedical materials like polytetrafluoroethylene (PTFE) may induce thrombosis and intimal hyperplasia due to the lack of an endothelial cell layer. Modification of the PTFE in an aqueous solution is difficult because of its hydrophobicity. Herein, aiming to simultaneously promote endothelial cell affinity and antithrombogenicity, a mussel-inspired modification approach was employed to enable the grafting of various bioactive molecules like RGD and heparin. This approach involves a series of pragmatic steps including oxygen plasma treatment, dopamine (DA) coating, polyethylenimine (PEI) grafting, and RGD or RGD/heparin immobilization. Successful modification in each step was verified via Fourier transform infrared (FTIR) spectroscopy and X-ray photoelectron spectroscopy (XPS). Plasma treatment increased the hydrophilicity of PTFE, thereby allowing it to be efficiently coated with dopamine. Grafting of dopamine, RGD, and heparin led to an increase in surface roughness and a decrease in water contact angle due to increased surface energy. Platelet adhesion increased after dopamine and RGD modification, but it dramatically decreased when heparin was introduced. All of these modifications, especially the incorporation of RGD, showed favorable effects on endothelial cell attachment, viability, and proliferation. Due to strong cell-substrate interactions between endothelial cells and RGD, the RGD/heparin-grafted PTFE demonstrated high endothelial cell affinity. This facile modification method is highly suitable for all hydrophobic surfaces and provides a promising technique for SDVG modification to stimulate fast endothelialization and effective antithrombosis.
Collapse
Affiliation(s)
- Hao-Yang Mi
- Wisconsin Institute for Discovery, University of Wisconsin–Madison, WI, 53715, USA
- Department of Industrial Equipment and Control Engineering, South China University of Technology, Guangzhou, 510640, China
- Department of Mechanical Engineering, University of Wisconsin–Madison, WI, 53706, USA
| | - Xin Jing
- Wisconsin Institute for Discovery, University of Wisconsin–Madison, WI, 53715, USA
- Department of Industrial Equipment and Control Engineering, South China University of Technology, Guangzhou, 510640, China
- Department of Mechanical Engineering, University of Wisconsin–Madison, WI, 53706, USA
| | - James A. Thomsom
- Morgridge Institute for Research, University of Wisconsin–Madison, WI, 53715, USA
| | - Lih-Sheng Turng
- Wisconsin Institute for Discovery, University of Wisconsin–Madison, WI, 53715, USA
- Department of Mechanical Engineering, University of Wisconsin–Madison, WI, 53706, USA
| |
Collapse
|
17
|
Govindarajan T, Shandas R. Shape Memory Polymers Containing Higher Acrylate Content Display Increased Endothelial Cell Attachment. Polymers (Basel) 2017; 9:572. [PMID: 29707382 PMCID: PMC5922786 DOI: 10.3390/polym9110572] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/06/2017] [Accepted: 10/31/2017] [Indexed: 12/13/2022] Open
Abstract
Shape Memory Polymers (SMPs) are smart materials that can recall their shape upon the application of a stimulus, which makes them appealing materials for a variety of applications, especially in biomedical devices. Most prior SMP research has focused on tuning bulk properties; studying surface effects of SMPs may extend the use of these materials to blood-contacting applications, such as cardiovascular stents, where surfaces that support rapid endothelialization have been correlated to stent success. Here, we evaluate endothelial attachment onto the surfaces of a family of SMPs previously developed in our group that have shown promise for biomedical devices. Nine SMP formulations containing varying amounts of tert-Butyl acrylate (tBA) and Poly(ethylene glycol) dimethacrylate (PEGDMA) were analyzed for endothelial cell attachment. Dynamic mechanical analysis (DMA), contact angle studies, and atomic force microscopy (AFM) were used to verify bulk and surface properties of the SMPs. Human umbilical vein endothelial cell (HUVEC) attachment and viability was verified using fluorescent methods. Endothelial cells preferentially attached to SMPs with higher tBA content, which have rougher, more hydrophobic surfaces. HUVECs also displayed an increased metabolic activity on these high tBA SMPs over the course of the study. This class of SMPs may be promising candidates for next generation blood-contacting devices.
Collapse
Affiliation(s)
| | - Robin Shandas
- Department of Bioengineering, University of Colorado at Denver|Anschutz Medical Campus, Aurora, CO 80045, USA;
| |
Collapse
|
18
|
Chen L, He H, Wang M, Li X, Yin H. Surface Coating of Polytetrafluoroethylene with Extracellular Matrix and Anti-CD34 Antibodies Facilitates Endothelialization and Inhibits Platelet Adhesion Under Sheer Stress. Tissue Eng Regen Med 2017; 14:359-370. [PMID: 30603492 DOI: 10.1007/s13770-017-0044-3] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2016] [Revised: 11/30/2016] [Accepted: 12/05/2016] [Indexed: 12/11/2022] Open
Abstract
Expanded polytetrafluoroethylene (ePTFE) polymers do not support endothelialization because of nonconductive characteristics towards cellular attachment. Inner surface modification of the grafts can improve endothelialization and increase the long-term patency rate of the ePTFE vascular grafts. Here we reported a method of inner-surface modification of ePTFE vascular graft with extracellular matrix (ECM) and CD34 monoclonal antibodies (CD34 mAb) to stimulate the adhesion and proliferation of circulating endothelial progenitor cells on ePTFE graft to enhance graft endothelialization. The inner surface of ECM-coated ePTFE grafts were linked with CD34 mAb in the presence of 1-ethyl-3-(3-dimethylaminopropyl)carbodiimide/N-hydroxysuccinimide (EDC/NHS) solution and the physicochemical properties, surface morphology, biocompatibility, and hemocompatibility of the grafts were studied. The hydrophilicity of CD34 mAb-coated graft inner surface was significantly improved. Fourier transform infrared spectroscopy analysis confirmed ECM and CD34 mAb cross-linking in the ePTFE vascular grafts with our method. Scanning electron microscopy analysis showed protein layer covering uniformly on the inner surface of the modified grafts. The cell-counting kit-8 (CCK-8) assay confirmed that the modified graft has no obvious cytotoxicity. The modified graft showed a low hemolytic rate (0.9%) in the direct contact hemolysis test, suggesting the modification improved hemocompatibility of biopolymers. The modification also decreased adhesion of platelets, while significantly increased the adhesion of endothelial cells on the grafts. We conclude that our method enables ePTFE polymers modification with ECM and CD34 mAb, facilitates endothelialization, and inhibits platelet adhesion on the grafts, thus may increase the long-term patency rate of the prosthetic bypass grafts.
Collapse
Affiliation(s)
- Lei Chen
- 1Department of Vascular Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510080 China
| | - Haipeng He
- 2Department of Vascular Surgery, The First Affiliated Hospital of Ji'nan University, Guangzhou, 510630 China
| | - Mian Wang
- 1Department of Vascular Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510080 China
| | - Xiaoxi Li
- 1Department of Vascular Surgery, The First Affiliated Hospital of Sun Yat-Sen University, Guangzhou, 510080 China
| | - Henghui Yin
- 3Department of Vascular Surgery, The Third Affiliated Hospital, Sun Yat-Sen University, Guangzhou, 510080 China
| |
Collapse
|
19
|
Junkar I, Kulkarni M, Humpolíček P, Capáková Z, Burja B, Mazare A, Schmuki P, Mrak-Poljšak K, Flašker A, Žigon P, Čučnik S, Mozetič M, Tomšič M, Iglič A, Sodin-Semrl S. Could Titanium Dioxide Nanotubes Represent a Viable Support System for Appropriate Cells in Vascular Implants? ADVANCES IN BIOMEMBRANES AND LIPID SELF-ASSEMBLY 2017. [DOI: 10.1016/bs.abl.2016.12.001] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
20
|
Trimukhe AM, Pandiyaraj KN, Tripathi A, Melo JS, Deshmukh RR. Plasma Surface Modification of Biomaterials for Biomedical Applications. ADVANCED STRUCTURED MATERIALS 2017. [DOI: 10.1007/978-981-10-3328-5_3] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
|
21
|
Xiong Z, Liu F, Lin H, Li J, Wang Y. Covalent Bonding of Heparin on the Crystallized Poly(lactic acid) (PLA) Membrane to Improve Hemocompability via Surface Cross-Linking and Glycidyl Ether Reaction. ACS Biomater Sci Eng 2016; 2:2207-2216. [PMID: 33465896 DOI: 10.1021/acsbiomaterials.6b00413] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/27/2023]
Affiliation(s)
- Zhu Xiong
- Ningbo Institute of Materials
Technology and Engineering, Chinese Academy of Sciences, 1219 Zhongguan
West Road, Ningbo 315201, P.R. China
| | - Fu Liu
- Ningbo Institute of Materials
Technology and Engineering, Chinese Academy of Sciences, 1219 Zhongguan
West Road, Ningbo 315201, P.R. China
| | - Haibo Lin
- Ningbo Institute of Materials
Technology and Engineering, Chinese Academy of Sciences, 1219 Zhongguan
West Road, Ningbo 315201, P.R. China
| | - Jinglong Li
- Ningbo Institute of Materials
Technology and Engineering, Chinese Academy of Sciences, 1219 Zhongguan
West Road, Ningbo 315201, P.R. China
| | - Yi Wang
- Ningbo Institute of Materials
Technology and Engineering, Chinese Academy of Sciences, 1219 Zhongguan
West Road, Ningbo 315201, P.R. China
| |
Collapse
|
22
|
Chandy T, Rao GH. Preparation of Surface-Engineered Elastin/Lamin Nerve Guide Tubes of Poly(Lactic Acid)/Poly(Ethylene Vinyl Acetate). J BIOACT COMPAT POL 2016. [DOI: 10.1106/088391102026102] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022]
Abstract
In this study, a spray coating technique was used to prepare poly(lactic acid) (PLA) tubes. To improve the flexibility of these devices, an elastomeric polymer, poly(ethylene vinyl acetate) (PEVAc), was added to the PLA. The PLA/PEVAc tubes were further surface modified with elastin and laminin via carbodiimide and glutaraldehyde treatment. This study evaluated the surface graft matrix components (elastin and laminin) on PLA/PEVAc tubes as a method for regenerating biointeractive materials for nerve growth and tissue engineering.
Collapse
Affiliation(s)
- Thomas Chandy
- Department of Cardiology Mayo Mail Code:508, University of Minnesota, 420 Delaware St. SE, Minneapolis, MN 55455, USA
| | - Gundu H.R. Rao
- Department of Lab Medicine and Pathology, Mayo Mail Code:508, University of Minnesota, 420 Delaware St. SE, Minneapolis, MN 55455, USA
| |
Collapse
|
23
|
Wang X, Liu B, Zhang G, Liu L, Chen Q, Chen W, Li X. Effect of atomic oxygen irradiation on the structural and tribological characteristics of polytetrafluoroethylene and its composites. SURF INTERFACE ANAL 2016. [DOI: 10.1002/sia.6066] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Xiangli Wang
- Key Laboratory for Electronic Materials of the State Ethnic Affairs Commission, College of Electric Engineering; Northwest University for Nationalities; Lanzhou 730030 China
| | - Baixing Liu
- State Key Laboratory of Solid Lubrication; Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences; Lanzhou 730000 China
| | - Guoheng Zhang
- Key Laboratory for Electronic Materials of the State Ethnic Affairs Commission, College of Electric Engineering; Northwest University for Nationalities; Lanzhou 730030 China
| | - Liwei Liu
- Key Laboratory for Electronic Materials of the State Ethnic Affairs Commission, College of Electric Engineering; Northwest University for Nationalities; Lanzhou 730030 China
| | - Qiong Chen
- Key Laboratory for Electronic Materials of the State Ethnic Affairs Commission, College of Electric Engineering; Northwest University for Nationalities; Lanzhou 730030 China
| | - Wanjun Chen
- Key Laboratory for Electronic Materials of the State Ethnic Affairs Commission, College of Electric Engineering; Northwest University for Nationalities; Lanzhou 730030 China
| | - Xiaoyong Li
- Experimental Center; Northwest University for Nationalities; Lanzhou 730030 China
| |
Collapse
|
24
|
Gregory TS, Cheng R, Tang G, Mao L, Tse ZTH. The Magnetohydrodynamic Effect and its Associated Material Designs for Biomedical Applications: A State-of-the-Art Review. ADVANCED FUNCTIONAL MATERIALS 2016; 26:3942-3952. [PMID: 29527149 PMCID: PMC5844576 DOI: 10.1002/adfm.201504198] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
The presented article discusses recent advances in biomedical applications of classical Magnetohydrodynamics (MHD), with a focus on operating principles and associated material considerations. These applications address novel approaches to common biomedical problems from micro-particle sorting for lab-on-a-chip devices to advanced physiological monitoring techniques. 100 papers in the field of MHDs were reviewed with a focus on studies with direct biomedical applications. The body of literature was categorized into three primary areas of research including Material Considerations for MHD Applications, MHD Actuation Devices, and MHD Sensing Techniques. The state of the art in the field was examined and research topics were connected to provide a wide view of the field of biomedical MHDs. As this field develops, the need for advanced simulation and material design will continue to increase in importance in order to further expand its reach to maturity. As the field of biomedical MHDs continues to grow, advances towards micro-scale transitions will continue to be made, maintaining its clinically driven nature and moving towards real-world applications.
Collapse
Affiliation(s)
- T Stan Gregory
- College of Engineering, The University of Georgia, 597 D.W. Brooks Drive, Athens, GA 30602, USA
| | - Rui Cheng
- College of Engineering, The University of Georgia, 597 D.W. Brooks Drive, Athens, GA 30602, USA
| | - Guoyi Tang
- Advanced Materials Institute, Graduate School at Shenzhen, Tsinghua University 518055, China
| | - Leidong Mao
- College of Engineering, The University of Georgia, 597 D.W. Brooks Drive, Athens, GA 30602, USA
| | - Zion Tsz Ho Tse
- College of Engineering, The University of Georgia, 597 D.W. Brooks Drive, Athens, GA 30602, USA
| |
Collapse
|
25
|
Mechanical and biocompatibility performance of bicomponent polyester/silk fibroin small-diameter arterial prostheses. J Appl Biomater Funct Mater 2015; 13:e201-9. [PMID: 26108427 DOI: 10.5301/jabfm.5000225] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/21/2015] [Indexed: 11/20/2022] Open
Abstract
BACKGROUND In this study, we fabricated prototype bicomponent polyester/silk fibroin small-diameter arterial prostheses using a specially designed narrow ribbon shuttle loom. METHODS The 2-layered flat fabrics were then heatset on a mandrel to form tubes with a round cross section. RESULTS The woven samples had a wall thickness between 0.23 mm and 0.29 mm and an inner diameter between 3.53 mm and 3.95 mm, depending on the yarn type and the weave structure. CONCLUSIONS The bicomponent polyester/silk fibroin samples had superior bursting strength, circumferential strength and suture retention strength compared with a commercial small-diameter arterial prosthesis made from ePTFE. In addition, these prototype samples had greater suture retention strengths than a dog femoral artery, which indicates that they have adequate biostability for clinical use. While their amount of radial compliance was superior to that of the ePTFE commercial graft control, it did not match that of a natural artery. So there is still a need for future improvement in compliance. All of the woven prototypes had water permeability values between 26 and 180 ml/(cm(2)*min), which confirms that none of these arterial prostheses needs to be preclotted at the time of implantation. The biocompatibility of the woven prototypes was evaluated using porcine endothelial cells and an MTT assay. Their cytocompatibility was found to be superior to the ePTFE commercial control, and the level of cell attachment was observed to increase on these prototypes woven with a higher silk fibroin content.
Collapse
|
26
|
Kolar M, Mozetič M, Stana-Kleinschek K, Fröhlich M, Turk B, Vesel A. Covalent Binding of Heparin to Functionalized PET Materials for Improved Haemocompatibility. MATERIALS 2015; 8:1526-1544. [PMID: 28788016 PMCID: PMC5507051 DOI: 10.3390/ma8041526] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/18/2014] [Revised: 01/19/2015] [Accepted: 03/20/2015] [Indexed: 11/16/2022]
Abstract
The hemocompatibility of vascular grafts made from poly(ethylene terephthalate) (PET) is insufficient due to the rapid adhesion and activation of blood platelets that occur upon incubation with whole blood. PET polymer was treated with NHx radicals created by passing ammonia through gaseous plasma formed by a microwave discharge, which allowed for functionalization with amino groups. X-ray photoelectron spectroscopy characterization using derivatization with 4-chlorobenzaldehyde indicated that approximately 4% of the –NH2 groups were associated with the PET surface after treatment with the gaseous radicals. The functionalized polymers were coated with an ultra-thin layer of heparin and incubated with fresh blood. The free-hemoglobin technique, which is based on the haemolysis of erythrocytes, indicated improved hemocompatibility, which was confirmed by imaging the samples using confocal optical microscopy. A significant decrease in number of adhered platelets was observed on such samples. Proliferation of both human umbilical vein endothelial cells and human microvascular endothelial cells was enhanced on treated polymers, especially after a few hours of cell seeding. Thus, the technique represents a promising substitute for wet-chemical modification of PET materials prior to coating with heparin.
Collapse
Affiliation(s)
- Metod Kolar
- Jozef Stefan International Postgraduate School, Jamova 39, Ljubljana 1000, Slovenia.
| | - Miran Mozetič
- Plasma Laboratory, Institute Jozef Stefan, Jamova 39, Ljubljana 1000, Slovenia.
| | - Karin Stana-Kleinschek
- Faculty of Mechanical Engineering, University of Maribor, Smetanova 17, Maribor 2000, Slovenia.
| | - Mirjam Fröhlich
- Department of Biochemistry, Molecular and Structural Biology, Institute Jozef Stefan, Jamova 39, Ljubljana 1000, Slovenia.
- Educell Ltd., Prevale 9, Trzin 1236, Slovenia.
| | - Boris Turk
- Department of Biochemistry, Molecular and Structural Biology, Institute Jozef Stefan, Jamova 39, Ljubljana 1000, Slovenia.
| | - Alenka Vesel
- Plasma Laboratory, Institute Jozef Stefan, Jamova 39, Ljubljana 1000, Slovenia.
| |
Collapse
|
27
|
Demina TS, Gilman AB, Akopova TA, Zelenetskii AN. Modification of the chitosan structure and properties using high-energy chemistry methods. HIGH ENERGY CHEMISTRY 2014. [DOI: 10.1134/s0018143914050063] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
28
|
A Survey of Surface Modification Techniques for Next-Generation Shape Memory Polymer Stent Devices. Polymers (Basel) 2014. [DOI: 10.3390/polym6092309] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
|
29
|
Liu X, Yuan L, Li D, Tang Z, Wang Y, Chen G, Chen H, Brash JL. Blood compatible materials: state of the art. J Mater Chem B 2014; 2:5718-5738. [PMID: 32262016 DOI: 10.1039/c4tb00881b] [Citation(s) in RCA: 204] [Impact Index Per Article: 20.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
Devices that function in contact with blood are ubiquitous in clinical medicine and biotechnology. These devices include vascular grafts, coronary stents, heart valves, catheters, hemodialysers, heart-lung bypass systems and many others. Blood contact generally leads to thrombosis (among other adverse outcomes), and no material has yet been developed which remains thrombus-free indefinitely and in all situations: extracorporeally, in the venous circulation and in the arterial circulation. In this article knowledge on blood-material interactions and "thromboresistant" materials is reviewed. Current approaches to the development of thromboresistant materials are discussed including surface passivation; incorporation and/or release of anticoagulants, antiplatelet agents and thrombolytic agents; and mimicry of the vascular endothelium.
Collapse
Affiliation(s)
- Xiaoli Liu
- The Key Lab of Health Chemistry and Molecular Diagnosis of Suzhou, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, P. R. China.
| | | | | | | | | | | | | | | |
Collapse
|
30
|
Wei Q, Becherer T, Angioletti-Uberti S, Dzubiella J, Wischke C, Neffe AT, Lendlein A, Ballauff M, Haag R. Protein Interactions with Polymer Coatings and Biomaterials. Angew Chem Int Ed Engl 2014; 53:8004-31. [DOI: 10.1002/anie.201400546] [Citation(s) in RCA: 524] [Impact Index Per Article: 52.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2014] [Indexed: 01/07/2023]
|
31
|
Wei Q, Becherer T, Angioletti-Uberti S, Dzubiella J, Wischke C, Neffe AT, Lendlein A, Ballauff M, Haag R. Wechselwirkungen von Proteinen mit Polymerbeschichtungen und Biomaterialien. Angew Chem Int Ed Engl 2014. [DOI: 10.1002/ange.201400546] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
32
|
Kundu B, Schlimp CJ, Nürnberger S, Redl H, Kundu SC. Thromboelastometric and platelet responses to silk biomaterials. Sci Rep 2014; 4:4945. [PMID: 24824624 PMCID: PMC4018936 DOI: 10.1038/srep04945] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2013] [Accepted: 04/17/2014] [Indexed: 12/02/2022] Open
Abstract
Silkworm's silk is natural biopolymer with unique properties including mechanical robustness, all aqueous base processing and ease in fabrication into different multifunctional templates. Additionally, the nonmulberry silks have cell adhesion promoting tri-peptide (RGD) sequences, which make it an immensely potential platform for regenerative medicine. The compatibility of nonmulberry silk with human blood is still elusive; thereby, restricts its further application as implants. The present study, therefore, evaluate the haematocompatibility of silk biomaterials in terms of platelet interaction after exposure to nonmulberry silk of Antheraea mylitta using thromboelastometry (ROTEM). The mulberry silk of Bombyx mori and clinically used Uni-Graft W biomaterial serve as references. Shortened clotting time, clot formation times as well as enhanced clot strength indicate the platelet mediated activation of blood coagulation cascade by tested biomaterials; which is comparable to controls.
Collapse
Affiliation(s)
- Banani Kundu
- Department of Biotechnology, Indian Institute of Technology, Kharagpur-721302, India
- These authors contributed equally to this work
| | - Christoph J. Schlimp
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Centre, Austrian Cluster for Tissue Regeneration, Vienna, Austria
- These authors contributed equally to this work
| | - Sylvia Nürnberger
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Centre, Austrian Cluster for Tissue Regeneration, Vienna, Austria
| | - Heinz Redl
- Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, AUVA Research Centre, Austrian Cluster for Tissue Regeneration, Vienna, Austria
| | - S. C. Kundu
- Department of Biotechnology, Indian Institute of Technology, Kharagpur-721302, India
| |
Collapse
|
33
|
Conn G, Kidane AG, Punshon G, Kannan RY, Hamilton G, Seifalian AM. Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices? Expert Rev Med Devices 2014; 3:245-61. [PMID: 16515390 DOI: 10.1586/17434440.3.2.245] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
To reduce the toxic effects, related clinical problems and complications such as bleeding disorders associated with systemic anticoagulation, it has been hypothesized that by coating the surfaces of medical devices, such as stents, bypass grafts, extracorporeal circuits, guide wires and catheters, there will be a significant reduction in the requirement for systemic anticoagulation or, ideally, it will no longer be necessary. However, current coating processes, even covalent ones, still result in leaching followed by reduced functionality. Alternative anticoagulants and related antiplatelet agents have been used for improvement in terms of reduced restenosis, intimal hyperphasia and device failure. This review focuses on existing heparinization processes, their application in clinical devices and the updated list of alternatives to heparinization in order to obtain a broad overview, it then highlights, in particular, the future possibilities of using heparin and related moieties to tissue engineer scaffolds.
Collapse
Affiliation(s)
- Gemma Conn
- Biomaterials & Tissue Engineering Centre, Academic Division of Surgical and Interventional Sciences, University College London, Rowland Hill Street, Hampstead, London NW3 2PF, UK
| | | | | | | | | | | |
Collapse
|
34
|
Cytocompatibility of a silk fibroin tubular scaffold. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2014; 34:429-36. [DOI: 10.1016/j.msec.2013.09.039] [Citation(s) in RCA: 55] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/08/2013] [Revised: 09/18/2013] [Accepted: 09/28/2013] [Indexed: 11/19/2022]
|
35
|
Hou J, Shi Q, Stagnaro P, Ye W, Jin J, Conzatti L, Yin J. Aqueous-based immobilization of initiator and surface-initiated ATRP to construct hemocompatible surface of poly (styrene-b-(ethylene-co-butylene)-b-styrene) elastomer. Colloids Surf B Biointerfaces 2013; 111:333-41. [DOI: 10.1016/j.colsurfb.2013.06.029] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2013] [Revised: 06/09/2013] [Accepted: 06/13/2013] [Indexed: 12/23/2022]
|
36
|
Shi J, Lu L, Guo W, Zhang J, Cao Y. Heat insulation performance, mechanics and hydrophobic modification of cellulose–SiO2 composite aerogels. Carbohydr Polym 2013; 98:282-9. [DOI: 10.1016/j.carbpol.2013.05.082] [Citation(s) in RCA: 93] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2013] [Revised: 05/03/2013] [Accepted: 05/28/2013] [Indexed: 11/16/2022]
|
37
|
Shi J, Lu L, Guo W, Sun Y, Cao Y. An environment-friendly thermal insulation material from cellulose and plasma modification. J Appl Polym Sci 2013. [DOI: 10.1002/app.39615] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Affiliation(s)
- Jianjun Shi
- Key Lab of Advanced Materials of Tropical Island Resources, Ministry of Education, College of Materials and Chemical Engineering, Hainan University; Haikou; 570228; People's Republic of China
| | - Lingbin Lu
- Key Lab of Advanced Materials of Tropical Island Resources, Ministry of Education, College of Materials and Chemical Engineering, Hainan University; Haikou; 570228; People's Republic of China
| | - Wantao Guo
- Key Lab of Advanced Materials of Tropical Island Resources, Ministry of Education, College of Materials and Chemical Engineering, Hainan University; Haikou; 570228; People's Republic of China
| | - Yujia Sun
- Key Lab of Advanced Materials of Tropical Island Resources, Ministry of Education, College of Materials and Chemical Engineering, Hainan University; Haikou; 570228; People's Republic of China
| | - Yang Cao
- Key Lab of Advanced Materials of Tropical Island Resources, Ministry of Education, College of Materials and Chemical Engineering, Hainan University; Haikou; 570228; People's Republic of China
| |
Collapse
|
38
|
Liu F, Grainger DW. Fluorinated Biomaterials. Biomater Sci 2013. [DOI: 10.1016/b978-0-08-087780-8.00011-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
39
|
Kondyurin AV, Naseri P, Tilley JMR, Nosworthy NJ, Bilek MMM, McKenzie DR. Mechanisms for covalent immobilization of horseradish peroxidase on ion-beam-treated polyethylene. SCIENTIFICA 2012; 2012:126170. [PMID: 24278665 PMCID: PMC3820519 DOI: 10.6064/2012/126170] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/21/2012] [Accepted: 11/20/2012] [Indexed: 05/26/2023]
Abstract
The surface of polyethylene was modified by plasma immersion ion implantation. Structure changes including carbonization and oxidation were observed. High surface energy of the modified polyethylene was attributed to the presence of free radicals on the surface. The surface energy decay with storage time after treatment was explained by a decay of the free radical concentration while the concentration of oxygen-containing groups increased with storage time. Horseradish peroxidase was covalently attached onto the modified surface by the reaction with free radicals. Appropriate blocking agents can block this reaction. All aminoacid residues can take part in the covalent attachment process, providing a universal mechanism of attachment for all proteins. The native conformation of attached protein is retained due to hydrophilic interactions in the interface region. The enzymatic activity of covalently attached protein remained high. The long-term activity of the modified layer to attach protein is explained by stabilisation of unpaired electrons in sp(2) carbon structures. A high concentration of free radicals can give multiple covalent bonds to the protein molecule and destroy the native conformation and with it the catalytic activity. The universal mechanism of protein attachment to free radicals could be extended to various methods of radiation damage of polymers.
Collapse
Affiliation(s)
- Alexey V. Kondyurin
- Applied and Plasma Physics, School of Physics, University of Sydney, A28, Sydney, NSW 2006, Australia
| | - Pourandokht Naseri
- Applied and Plasma Physics, School of Physics, University of Sydney, A28, Sydney, NSW 2006, Australia
| | - Jennifer M. R. Tilley
- Applied and Plasma Physics, School of Physics, University of Sydney, A28, Sydney, NSW 2006, Australia
| | - Neil J. Nosworthy
- Applied and Plasma Physics, School of Physics, University of Sydney, A28, Sydney, NSW 2006, Australia
| | - Marcela M. M. Bilek
- Applied and Plasma Physics, School of Physics, University of Sydney, A28, Sydney, NSW 2006, Australia
| | - David R. McKenzie
- Applied and Plasma Physics, School of Physics, University of Sydney, A28, Sydney, NSW 2006, Australia
| |
Collapse
|
40
|
Wise SG, Waterhouse A, Kondyurin A, Bilek MM, Weiss AS. Plasma-based biofunctionalization of vascular implants. Nanomedicine (Lond) 2012; 7:1907-16. [DOI: 10.2217/nnm.12.161] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023] Open
Abstract
Polymeric and metallic materials are used extensively in permanently implanted cardiovascular devices and devices that make temporary but often prolonged contact with body fluids and tissues. Foreign body responses are typically triggered by host interactions at the implant surface, making surface modifications to increase biointegration desirable. Plasma-based treatments are extensively used to modify diverse substrates; modulating surface chemistry, wettability and surface roughness, as well as facilitating covalent biomolecule binding. Each aspect impacts on facets of vascular compatibility including endothelialization and blood contact. These modifications can be readily applied to polymers such as Dacron® and expanded polytetrafluoroethylene, which are widely used in bypass grafting and the metallic substrates of stents, valves and pacemaker components. Plasma modification of metals is more challenging given the need for coating deposition in addition to surface activation, adding the necessity for robust interface adhesion. This review examines the evolving plasma treatment technology facilitating the biofunctionalization of polymeric and metallic implantable cardiovascular materials.
Collapse
Affiliation(s)
- Steven G Wise
- School of Molecular Bioscience, University of Sydney, NSW 2006, Australia; School of Molecular Bioscience G08, University of Sydney, NSW 2006, Australia
- The Heart Research Institute, Sydney, NSW 2042, Australia
| | - Anna Waterhouse
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA 02115, USA
| | | | - Marcela M Bilek
- School of Physics, University of Sydney, NSW 2006, Australia
| | - Anthony S Weiss
- Bosch Institute, University of Sydney, Sydney, 2006, Australia
- Charles Perkins Centre, University of Sydney, Sydney, 2006, Australia
| |
Collapse
|
41
|
Hoshi RA, Van Lith R, Jen MC, Allen JB, Lapidos KA, Ameer G. The blood and vascular cell compatibility of heparin-modified ePTFE vascular grafts. Biomaterials 2012; 34:30-41. [PMID: 23069711 DOI: 10.1016/j.biomaterials.2012.09.046] [Citation(s) in RCA: 190] [Impact Index Per Article: 15.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2012] [Accepted: 09/21/2012] [Indexed: 12/21/2022]
Abstract
Prosthetic vascular grafts do not mimic the antithrombogenic properties of native blood vessels and therefore have higher rates of complications that involve thrombosis and restenosis. We developed an approach for grafting bioactive heparin, a potent anticoagulant glycosaminoglycan, to the lumen of ePTFE vascular grafts to improve their interactions with blood and vascular cells. Heparin was bound to aminated poly(1,8-octanediol-co-citrate) (POC) via its carboxyl functional groups onto POC-modified ePTFE grafts. The bioactivity and stability of the POC-immobilized heparin (POC-Heparin) were characterized via platelet adhesion and clotting assays. The effects of POC-Heparin on the adhesion, viability and phenotype of primary endothelial cells (EC), blood outgrowth endothelial cells (BOECs) obtained from endothelial progenitor cells (EPCs) isolated from human peripheral blood, and smooth muscle cells were also investigated. POC-Heparin grafts maintained bioactivity under physiologically relevant conditions in vitro for at least one month. Specifically, POC-Heparin-coated ePTFE grafts significantly reduced platelet adhesion and inhibited whole blood clotting kinetics. POC-Heparin supported EC and BOEC adhesion, viability, proliferation, NO production, and expression of endothelial cell-specific markers von Willebrand factor (vWF) and vascular endothelial-cadherin (VE-cadherin). Smooth muscle cells cultured on POC-Heparin showed increased expression of α-actin and decreased cell proliferation. This approach can be easily adapted to modify other blood contacting devices such as stents where antithrombogenicity and improved endothelialization are desirable properties.
Collapse
Affiliation(s)
- Ryan A Hoshi
- Biomedical Engineering Department, Northwestern University, Evanston, IL 60208, USA
| | | | | | | | | | | |
Collapse
|
42
|
Nguyen TH, Lee BT. The effect of cross-linking on the microstructure, mechanical properties and biocompatibility of electrospun polycaprolactone-gelatin/PLGA-gelatin/PLGA-chitosan hybrid composite. SCIENCE AND TECHNOLOGY OF ADVANCED MATERIALS 2012; 13:035002. [PMID: 27877490 PMCID: PMC5090279 DOI: 10.1088/1468-6996/13/3/035002] [Citation(s) in RCA: 38] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2011] [Accepted: 04/09/2012] [Indexed: 06/06/2023]
Abstract
In this study, multilayered scaffolds composed of polycaprolactone (PCL)-gelatin/poly(lactic-co-glycolic acid) (PLGA)-gelatin/PLGA-chitosan artificial blood vessels were fabricated using a double-ejection electrospinning system. The mixed fibers from individual materials were observed by scanning electron microscopy. The effects of the cross-linking process on the microstructure, mechanical properties and biocompatibility of the fibers were examined. The tensile stress and liquid strength of the cross-linked artificial blood vessels were 2.3 MPa and 340 mmHg, respectively, and were significantly higher than for the non-cross-linked vessel (2.0 MPa and 120 mmHg). The biocompatibility of the cross-linked artificial blood vessel scaffold was examined using the MTT assay and by evaluating cell attachment and cell proliferation. The cross-linked PCL-gelatin/PLGA-gelatin/PLGA-chitosan artificial blood vessel scaffold displayed excellent flexibility, was able to withstand high pressures and promoted cell growth; thus, this novel material holds great promise for eventual use in artificial blood vessels.
Collapse
|
43
|
Gong YK, Liu LP, Messersmith PB. Doubly Biomimetic Catecholic Phosphorylcholine Copolymer: A Platform Strategy for Fabricating Antifouling Surfaces. Macromol Biosci 2012; 12:979-85. [DOI: 10.1002/mabi.201200074] [Citation(s) in RCA: 58] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2012] [Indexed: 11/12/2022]
|
44
|
Li C, Hill A, Imran M. In vitro and in vivo studies of ePTFE vascular grafts treated with P15 peptide. JOURNAL OF BIOMATERIALS SCIENCE-POLYMER EDITION 2012; 16:875-91. [PMID: 16128294 DOI: 10.1163/1568562054255754] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
Abstract
The purpose of this study is to evaluate the effectiveness of P15 cell-binding peptide treated ePTFE vascular grafts in vitro and in vivo. The P15 peptide was covalently immobilized onto ePTFE vascular grafts by an atmospheric plasma coating method. In vitro cell growth properties were studied using primary human umbilical vein endothelial cells (HUVECs) and primary human umbilical artery smooth muscle cells (HUASMCs). X-ray photoelectron spectroscopy and amino-acid analysis were used to analyze the surface characteristics of the peptide treated and untreated grafts. The cell growth study showed that the P15 peptide effectively promoted the adhesion and proliferation of endothelial cells. 700% more endothelial cells were proliferated on the P15-treated ePTFE grafts compared to the untreated ePTFE controls. In contrast, the P15 peptide was significantly less effective for promoting the adhesion and proliferation of smooth muscle cells than endothelial cells; only about 100% more smooth muscle cells proliferated on the P15-treated samples compared to the untreated control samples. The sheep model was used in the in vivo study. The amount of neointimal hyperplasia present at the arterial and venous sides of the anastomosis and the degree of endothelialization on the luminal surface of the grafts were assessed. Four P15-treated grafts and two control grafts were implanted as arteriovenous grafts between the femoral artery and vein or the carotid artery and jugular vein in two sheep (n = 6). The in vivo study showed that the thickness of the neointimal hyperplasia of untreated grafts was 3-times thicker than that of P15-treated grafts (P < 0.05) at the venous side of the anastomosis. P15-treated grafts also had a higher degree of endothelialization on the graft lumen.
Collapse
Affiliation(s)
- Cheng Li
- InCube, Inc., 1390 Willow Road, Menlo Park, CA 94025, USA.
| | | | | |
Collapse
|
45
|
Tatterton M, Wilshaw SP, Ingham E, Homer-Vanniasinkam S. The use of antithrombotic therapies in reducing synthetic small-diameter vascular graft thrombosis. Vasc Endovascular Surg 2012; 46:212-22. [PMID: 22308212 DOI: 10.1177/1538574411433299] [Citation(s) in RCA: 37] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Thrombosis of synthetic small-diameter bypass grafts remains a major problem. The aim of this article is to review the antithrombotic strategies that have been used in an attempt to reduce graft thrombogenicity. METHODS A PubMed/MEDLINE search was performed using the search terms "vascular graft thrombosis," "small-diameter graft thrombosis," "synthetic graft thrombosis" combined with "antithrombotic," "antiplatelet," "anticoagulant," "Dacron," "PTFE," and "polyurethane." RESULTS The majority of studies on antithrombotic therapies have used either in vitro models or in vivo animal experiments. Many of the therapies used in these settings do show antithrombotic efficacy against synthetic graft materials. There is however, a distinct lack of human in vivo studies to further delineate the performance and limitations of therapies displaying good antithrombotic characteristics. CONCLUSION Very few antithrombotic therapies have translated into clinical use. More human in vivo studies are required to assess the efficacy and safety of such therapies.
Collapse
Affiliation(s)
- Mark Tatterton
- Leeds Vascular Institute, Leeds General Infirmary, Leeds, Yorkshire, UK.
| | | | | | | |
Collapse
|
46
|
Xu A, Yuan WZ, Zhao J, Li H, Zhang H, Zhang Y. Copolymerizations of tetrafluoroethylene and perfluoropropylvinyl ether in supercritical carbon dioxide: Polymer synthesis, characterization, and thermal properties. J Appl Polym Sci 2011. [DOI: 10.1002/app.35187] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
47
|
Solouk A, Cousins BG, Mirzadeh H, Seifalian AM. Application of plasma surface modification techniques to improve hemocompatibility of vascular grafts: A review. Biotechnol Appl Biochem 2011; 58:311-27. [PMID: 21995534 DOI: 10.1002/bab.50] [Citation(s) in RCA: 42] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2011] [Accepted: 08/12/2011] [Indexed: 12/14/2022]
Affiliation(s)
- Atefeh Solouk
- Polymer Engineering Faculty, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | | | | | | |
Collapse
|
48
|
Lee WH, Loo CY, Van KL, Zavgorodniy AV, Rohanizadeh R. Modulating protein adsorption onto hydroxyapatite particles using different amino acid treatments. J R Soc Interface 2011; 9:918-27. [PMID: 21957116 DOI: 10.1098/rsif.2011.0586] [Citation(s) in RCA: 56] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
Hydroxyapatite (HA) is a material of choice for bone grafts owing to its chemical and structural similarities to the mineral phase of hard tissues. The combination of osteogenic proteins with HA materials that carry and deliver the proteins to the bone-defective areas will accelerate bone regeneration. The study investigated the treatment of HA particles with different amino acids such as serine (Ser), asparagine (Asn), aspartic acid (Asp) and arginine (Arg) to enhance the adsorption ability of HA carrier for delivering therapeutic proteins to the body. The crystallinity of HA reduced when amino acids were added during HA preparation. Depending on the types of amino acid, the specific surface area of the amino acid-functionalized HA particles varied from 105 to 149 m(2) g(-1). Bovine serum albumin (BSA) and lysozyme were used as model proteins for adsorption study. The protein adsorption onto the surface of amino acid-functionalized HA depended on the polarities of HA particles, whereby, compared with lysozyme, BSA demonstrated higher affinity towards positively charged Arg-HA. Alternatively, the binding affinity of lysozyme onto the negatively charged Asp-HA was higher when compared with BSA. The BSA and lysozyme adsorptions onto the amino acid-functionalized HA fitted better into the Freundlich than Langmuir model. The amino acid-functionalized HA particles that had higher protein adsorption demonstrated a lower protein-release rate.
Collapse
Affiliation(s)
- Wing-Hin Lee
- Advanced Drug Delivery Group, Faculty of Pharmacy, University of Sydney, Sydney, New South Wales 2006, Australia
| | | | | | | | | |
Collapse
|
49
|
Low molecular weight heparin-all-trans-retinoid acid conjugate as a drug carrier for combination cancer chemotherapy of paclitaxel and all-trans-retinoid acid. Carbohydr Polym 2011. [DOI: 10.1016/j.carbpol.2011.06.008] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
50
|
Lovett M, Eng G, Kluge JA, Cannizzaro C, Vunjak-Novakovic G, Kaplan DL. Tubular silk scaffolds for small diameter vascular grafts. Organogenesis 2011; 6:217-24. [PMID: 21220960 DOI: 10.4161/org.6.4.13407] [Citation(s) in RCA: 133] [Impact Index Per Article: 10.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023] Open
Abstract
Vascular surgeries such as coronary artery bypass require small diameter vascular grafts with properties that are not available at this time. Approaches using synthetic biomaterials have been not completely successful in producing non-thrombogenic grafts with inner diameters less than 6 mm, and there is a need for new biomaterials and graft designs. We propose silk fibroin as a microvascular graft material and describe tubular silk scaffolds that demonstrate improved properties over existing vascular graft materials. Silk tubes produced using an aqueous gel spinning technique were first assessed in vitro in terms of thrombogenicity (thrombin and fibrinogen adsorption, platelet adhesion) and vascular cell responses (endothelial and smooth muscle cell attachment and proliferation) in comparison with polytetrafluoroethylene (PTFE), a synthetic material most frequently used for vascular grafts. Silk tubes were then implanted into the abdominal aortas of Sprague-Dawley rats. At time points of 2 weeks and 4 weeks post implantation, tissue outcomes were assessed through gross observation (acute thrombosis, patency) and histological staining (H&E, Factor VIII, smooth muscle actin). Over the 4-week time period, we observed graft patency and endothelial cell lining of the lumen surfaces. These results demonstrate the feasibility of using silk fibroin as a vascular graft material and some advantages of silk tubes over the currently used synthetic grafts.
Collapse
Affiliation(s)
- Michael Lovett
- Department of Biomedical Engineering, Tufts University, Medford, MA, USA
| | | | | | | | | | | |
Collapse
|