1
|
van Galen DJM, Meinders Q, Halfwerk FR, Arens J. ECMOve: A Mobilization Device for Extracorporeal Membrane Oxygenation Patients. ASAIO J 2024; 70:377-386. [PMID: 38324706 PMCID: PMC11057491 DOI: 10.1097/mat.0000000000002153] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/09/2024] Open
Abstract
Extracorporeal membrane oxygenation (ECMO) is a temporary lifesaving treatment for critically ill patients with severe respiratory or cardiac failure. Studies demonstrated the feasibility of in-hospital mobilizing during and after ECMO treatment preventing neuromuscular weakness and impaired physical functioning. Despite more compact mobile ECMO devices, implementation of ambulatory ECMO remains labor-intensive, complex, and challenging. It requires a large multidisciplinary team to carry equipment, monitor and physically support the patient, and to provide a back-up wheelchair in case of fatigue. Moreover, there is no adequate solution to ensure the stability of the patient's cannula and circuit management during ambulation. We developed a system contributing to improvement and innovation of current ambulatory ECMO patient programs. Our modular cart-in-cart system carries necessary ECMO equipment, features an extendable walking frame, and contains a folding seat for patient transport. An adjustable shoulder brace with lockable tubing-connectors enables safe fixation of the blood tubing. ECMOve provides safety, support, and accessibility while performing ambulatory ECMO for both patient and caregiver. Prototype evaluation in a simulated intensive care unit showed feasibility of our design, but needs to be evaluated in clinical care.
Collapse
Affiliation(s)
- Danny J. M. van Galen
- From the Faculty of Engineering Technologies, Department of Biomechanical Engineering, Engineering Organ Support Technologies, University of Twente, Enschede, the Netherlands
| | - Quint Meinders
- From the Faculty of Engineering Technologies, Department of Biomechanical Engineering, Engineering Organ Support Technologies, University of Twente, Enschede, the Netherlands
| | - Frank R. Halfwerk
- From the Faculty of Engineering Technologies, Department of Biomechanical Engineering, Engineering Organ Support Technologies, University of Twente, Enschede, the Netherlands
- Department of Cardiothoracic Surgery, Thorax Centrum Twente, Medisch Spectrum Twente, Enschede, the Netherlands
| | - Jutta Arens
- From the Faculty of Engineering Technologies, Department of Biomechanical Engineering, Engineering Organ Support Technologies, University of Twente, Enschede, the Netherlands
| |
Collapse
|
2
|
Strudthoff LJ, Hesselmann F, Clauser JC, Arens J. Refurbishment of Extracorporeal Life Support Oxygenators in the Context of In Vitro Testing. ASAIO J 2023; 69:924-931. [PMID: 37314830 DOI: 10.1097/mat.0000000000001999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023] Open
Abstract
Refurbishing single use extracorporeal membrane oxygenation (ECMO) oxygenators for in vitro research applications is common. However, the refurbishment protocols that are established in respective laboratories have never been evaluated. In the present study, we aim at proving the relevance of a well-designed refurbishing protocol by quantifying the burden of repeatedly reused oxygenators. We used the same three oxygenators in 5 days of 6 hours whole blood experiments. During each experiment day, the performance of the oxygenators was measured through the evaluation of gas transfer. Between experiment days, each oxygenator was refurbished applying three alternative refurbishment protocols based on purified water, pepsin and citric acid, and hydrogen peroxide solutions, respectively. After the last experiment day, we disassembled the oxygenators for visual inspection of the fiber mats. The refurbishment protocol based on purified water showed strong degeneration with a 40-50 %-performance drop and clearly visible debris on the fiber mats. Hydrogen peroxide performed better; nevertheless, it suffered a 20% decrease in gas transfer as well as clearly visible debris. Pepsin/citric acid performed best in the field, but also suffered from 10% performance loss and very few, but visible debris. The study showed the relevance of a well-suited and well-designed refurbishment protocol. The distinct debris on the fiber mats also suggests that reusing oxygenators is ill-advised for many experiment series, especially regarding hemocompatibility and in vivo testing. Most of all, this study revealed the relevance of stating the status of test oxygenators and, if refurbished, comment on the implemented refurbishment protocol in detail.
Collapse
Affiliation(s)
- Lasse J Strudthoff
- From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Felix Hesselmann
- From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
- Enmodes GmbH, Aachen, Germany
| | - Johanna C Clauser
- From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- From the Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
3
|
Hugenroth K, Krooß F, Hima F, Strudthoff L, Kopp R, Arens J, Kalverkamp S, Steinseifer U, Neidlin M, Spillner J. Inflow from a Cardiopulmonary Assist System to the Pulmonary Artery and Its Implications for Local Hemodynamics-a Computational Fluid Dynamics Study. J Cardiovasc Transl Res 2023; 16:842-851. [PMID: 36662482 PMCID: PMC10480287 DOI: 10.1007/s12265-022-10349-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/31/2022] [Accepted: 12/19/2022] [Indexed: 01/21/2023]
Abstract
When returning blood to the pulmonary artery (PA), the inflow jet interferes with local hemodynamics. We investigated the consequences for several connection scenarios using transient computational fluid dynamics simulations. The PA was derived from CT data. Three aspects were varied: graft flow rate, anastomosis location, and inflow jet path length from anastomosis site to impingement on the PA wall. Lateral anastomosis locations caused abnormal flow distribution between the left and right PA. The central location provided near-physiological distribution but induced higher wall shear stress (WSS). All effects were most pronounced at high graft flows. A central location is beneficial regarding flow distribution, but the resulting high WSS might promote detachment of local thromboembolisms or influence the autonomic nervous innervation. Lateral locations, depending on jet path length, result in lower WSS at the cost of an unfavorable flow distribution that could promote pulmonary vasculature changes. Case-specific decisions and further research are necessary.
Collapse
Affiliation(s)
- Kristin Hugenroth
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
| | - Felix Krooß
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Flutura Hima
- Department of Thoracic and Cardiovascular Surgery, Medical Faculty, University Hospital, RWTH Aachen University, Aachen, Germany
| | - Lasse Strudthoff
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Rüdger Kopp
- Department of Intensive Care Medicine and Intermediate Care, Medical Faculty, University Hospital, RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Sebastian Kalverkamp
- Department of Thoracic and Cardiovascular Surgery, Medical Faculty, University Hospital, RWTH Aachen University, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Michael Neidlin
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Jan Spillner
- Department of Thoracic and Cardiovascular Surgery, Medical Faculty, University Hospital, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
4
|
Strudthoff LJ, Focke J, Hesselmann F, Kaesler A, Martins Costa A, Schlanstein PC, Schmitz-Rode T, Steinseifer U, Steuer NB, Wiegmann B, Arens J, Jansen SV. Novel Size-Variable Dedicated Rodent Oxygenator for ECLS Animal Models-Introduction of the "RatOx" Oxygenator and Preliminary In Vitro Results. Micromachines (Basel) 2023; 14:800. [PMID: 37421033 DOI: 10.3390/mi14040800] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 03/22/2023] [Accepted: 03/24/2023] [Indexed: 07/09/2023]
Abstract
The overall survival rate of extracorporeal life support (ECLS) remains at 60%. Research and development has been slow, in part due to the lack of sophisticated experimental models. This publication introduces a dedicated rodent oxygenator ("RatOx") and presents preliminary in vitro classification tests. The RatOx has an adaptable fiber module size for various rodent models. Gas transfer performances over the fiber module for different blood flows and fiber module sizes were tested according to DIN EN ISO 7199. At the maximum possible amount of effective fiber surface area and a blood flow of 100 mL/min, the oxygenator performance was tested to a maximum of 6.27 mL O2/min and 8.2 mL CO2/min, respectively. The priming volume for the largest fiber module is 5.4 mL, while the smallest possible configuration with a single fiber mat layer has a priming volume of 1.1 mL. The novel RatOx ECLS system has been evaluated in vitro and has demonstrated a high degree of compliance with all pre-defined functional criteria for rodent-sized animal models. We intend for the RatOx to become a standard testing platform for scientific studies on ECLS therapy and technology.
Collapse
Affiliation(s)
- Lasse J Strudthoff
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Jannis Focke
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Felix Hesselmann
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Andreas Kaesler
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Ana Martins Costa
- Department of Biomechanical Engineering, Faculty of Engineering Technologies, University of Twente, 7522 LW Enschede, The Netherlands
| | - Peter C Schlanstein
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Ulrich Steinseifer
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Niklas B Steuer
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| | - Bettina Wiegmann
- Department for Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, 30625 Hanover, Germany
- Lower Saxony Center for Biomedical Engineering, Implant Research and Development (NIFE), 30625 Hanover, Germany
- German Center for Lung Research (DLZ), 30625 Hanover, Germany
| | - Jutta Arens
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
- Department of Biomechanical Engineering, Faculty of Engineering Technologies, University of Twente, 7522 LW Enschede, The Netherlands
| | - Sebastian V Jansen
- Institute of Applied Medical Engineering, Department of Cardiovascular Engineering, Medical Faculty, RWTH Aachen University, 52074 Aachen, Germany
| |
Collapse
|
5
|
Arens J, Schraven L, Kaesler A, Flege C, Schmitz‐Rode T, Rossaint R, Steinseifer U, Kopp R. Development and evaluation of a variable, miniaturized oxygenator for various test methods. Artif Organs 2022; 47:695-704. [PMID: 36420613 DOI: 10.1111/aor.14465] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 10/13/2022] [Accepted: 11/09/2022] [Indexed: 11/25/2022]
Abstract
BACKGROUND Extracorporeal membrane oxygenation (ECMO) became an accepted therapy for the treatment of severe acute respiratory distress syndrome and chronic obstructive pulmonary disease. However, ECMO systems are still prone to thrombus formation and decrease of gas exchange over time. Therefore, it is necessary to conduct qualified studies to identify parameters for optimization of ECMO systems, and especially the oxygenator. However, commercially marketed oxygenators are not always appropriate and available for certain research use cases. Therefore, we aimed to design an oxygenator, which is suitable for various test conditions such as blood tests, numerical simulation, and membrane studies, and can be modified in membrane area size and manufactured in laboratory. METHODS Main design criteria are a homogeneous blood flow without stagnation zones, low pressure drop, manufacturability in the lab, size variability with one set of housing parts and cost-efficiency. Our newly designed oxygenator was tested comparatively regarding blood cell damage, gas transfer performance and pressure drop to prove the validity of the design in accordance with a commercial device. RESULTS No statistically significant difference between the tested oxygenators was detected and our new oxygenator demonstrated sufficient hemocompatibility. Furthermore, our variable oxygenator has proven that it can be easily manufactured in the laboratory, allows to use various membrane fiber configurations and can be reopened easily and non-destructively for analysis after use, and the original geometry is available for numerical simulations. CONCLUSION Therefore, we consider this newly developed device as a valuable tool for basic experimental and numerical research on the optimization of oxygenators.
Collapse
Affiliation(s)
- Jutta Arens
- Engineering Organ Support Technologies Group, Department of Biomechanical Engineering, Faculty of Engineering Technology University of Twente Enschede Netherlands
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | - Lotte Schraven
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | - Andreas Kaesler
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | - Christian Flege
- Department of Intensive Care Medicine, Medical Faculty RWTH Aachen University Aachen Germany
| | - Thomas Schmitz‐Rode
- Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | - Rolf Rossaint
- Department of Anesthesiology, Medical Faculty RWTH Aachen University Aachen Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | - Rüdger Kopp
- Department of Intensive Care Medicine, Medical Faculty RWTH Aachen University Aachen Germany
| |
Collapse
|
6
|
Klein M, Tack JC, Mager I, Maas J, Schmitz-Rode T, Arens J, Steinseifer U, Clauser JC. In vitro thrombogenicity evaluation of rotary blood pumps by thromboelastometry. BIOMED ENG-BIOMED TE 2022; 67:471-480. [PMID: 36041741 DOI: 10.1515/bmt-2022-0078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 08/02/2022] [Indexed: 11/15/2022]
Abstract
In vitro thrombogenicity tests for rotary blood pumps (RBPs) could benefit from assessing coagulation kinematics, as RBP design improves. In this feasibility study, we investigated if the method of thromboelastometry (TEM) is able to assess coagulation kinematics under the in vitro conditions of RBP tests. We conducted in vitro thrombogenicity tests (n=4) by placing Deltastream® DP3 pumps into test loops that were filled with 150 mL of slightly anti-coagulated porcine blood, adjusted to an activated clotting time (ACT) well below clinically recommended levels. Blood samples were taken at certain time points during the experiment until a continuous decrease in pump flow indicated major thrombus formation. Blood samples were analyzed for ACT, platelet count (PLT), and several TEM parameters. While visible thrombus formation was observed in three pumps, ACT indicated an ongoing activation of coagulation, PLT might have indicated platelet consumption. Unexpectedly, most TEM results gave no clear indications. Nonetheless, TEM clotting time obtained by non-anticoagulated and chemically non-activated whole blood (HEPNATEM-CT) appeared to be more sensitive for the activation of coagulation in vitro than ACT, which might be of interest for future pump tests. However, more research regarding standardization of thrombogenicity pump tests is urgently required.
Collapse
Affiliation(s)
- Mario Klein
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Jana Christine Tack
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Ilona Mager
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Judith Maas
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany.,Chair in Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Johanna Charlotte Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
7
|
Martins Costa A, Halfwerk F, Wiegmann B, Neidlin M, Arens J. Trends, Advantages and Disadvantages in Combined Extracorporeal Lung and Kidney Support From a Technical Point of View. Front Med Technol 2022; 4:909990. [PMID: 35800469 PMCID: PMC9255675 DOI: 10.3389/fmedt.2022.909990] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2022] [Accepted: 05/25/2022] [Indexed: 11/13/2022] Open
Abstract
Extracorporeal membrane oxygenation (ECMO) provides pulmonary and/or cardiac support for critically ill patients. Due to their diseases, they are at high risk of developing acute kidney injury. In that case, continuous renal replacement therapy (CRRT) is applied to provide renal support and fluid management. The ECMO and CRRT circuits can be combined by an integrated or parallel approach. So far, all methods used for combined extracorporeal lung and kidney support present serious drawbacks. This includes not only high risks of circuit related complications such as bleeding, thrombus formation, and hemolysis, but also increase in technical workload and health care costs. In this sense, the development of a novel optimized artificial lung device with integrated renal support could offer important treatment benefits. Therefore, we conducted a review to provide technical background on existing techniques for extracorporeal lung and kidney support and give insight on important aspects to be addressed in the development of this novel highly integrated artificial lung device.
Collapse
Affiliation(s)
- Ana Martins Costa
- Engineering Organ Support Technologies Group, Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
- *Correspondence: Ana Martins Costa
| | - Frank Halfwerk
- Engineering Organ Support Technologies Group, Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
- Department of Cardiothoracic Surgery, Thorax Centrum Twente, Medisch Spectrum Twente, Enschede, Netherlands
| | - Bettina Wiegmann
- Lower Saxony Center for Biomedical Engineering, Implant Research and Development, Hannover Medical School, Hanover, Germany
- Department of Cardiothoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hanover, Germany
- German Center for Lung Research, BREATH, Hannover Medical School, Hanover, Germany
| | - Michael Neidlin
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- Engineering Organ Support Technologies Group, Department of Biomechanical Engineering, University of Twente, Enschede, Netherlands
| |
Collapse
|
8
|
Hesselmann F, Halwes M, Bongartz P, Wessling M, Cornelissen C, Schmitz-Rode T, Steinseifer U, Jansen SV, Arens J. TPMS-based membrane lung with locally-modified permeabilities for optimal flow distribution. Sci Rep 2022; 12:7160. [PMID: 35504939 PMCID: PMC9065140 DOI: 10.1038/s41598-022-11175-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2021] [Accepted: 04/11/2022] [Indexed: 11/09/2022] Open
Abstract
Membrane lungs consist of thousands of hollow fiber membranes packed together as a bundle. The devices often suffer from complications because of non-uniform flow through the membrane bundle, including regions of both excessively high flow and stagnant flow. Here, we present a proof-of-concept design for a membrane lung containing a membrane module based on triply periodic minimal surfaces (TPMS). By warping the original TPMS geometries, the local permeability within any region of the module could be raised or lowered, allowing for the tailoring of the blood flow distribution through the device. By creating an iterative optimization scheme for determining the distribution of streamwise permeability inside a computational porous domain, the desired form of a lattice of TPMS elements was determined via simulation. This desired form was translated into a computer-aided design (CAD) model for a prototype device. The device was then produced via additive manufacturing in order to test the novel design against an industry-standard predicate device. Flow distribution was verifiably homogenized and residence time reduced, promising a more efficient performance and increased resistance to thrombosis. This work shows the promising extent to which TPMS can serve as a new building block for exchange processes in medical devices.
Collapse
Affiliation(s)
- Felix Hesselmann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.
| | - Michael Halwes
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Patrick Bongartz
- Chair of Chemical Process Engineering, RWTH Aachen University, Forckenbeckstr. 51, 52074, Aachen, Germany
| | - Matthias Wessling
- Chair of Chemical Process Engineering, RWTH Aachen University, Forckenbeckstr. 51, 52074, Aachen, Germany.,DWI-Leibniz Institute for Interactive Materials, RWTH Aachen University, Forckenbeckstr. 50, 52074, Aachen, Germany
| | - Christian Cornelissen
- Department of Pneumology and Internal Intensive Care Medicine, Medical Clinic V, RWTH Aachen University Hospital, Pauwelsstr. 30, 52074, Aachen, Germany
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Sebastian Victor Jansen
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Pauwelsstr. 20, 52074, Aachen, Germany.,Chair of Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering, Technology University of Twente, Enschede, The Netherlands
| |
Collapse
|
9
|
Vatani A, Liao S, Burrell AJC, Carberry J, Azimi M, Steinseifer U, Arens J, Soria J, Pellegrino V, Kaye D, Gregory SD. Improved Drainage Cannula Design to Reduce Thrombosis in Veno-Arterial Extracorporeal Membrane Oxygenation. ASAIO J 2022; 68:205-213. [PMID: 33883503 DOI: 10.1097/mat.0000000000001440] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Thrombosis is a potentially life-threatening complication in veno-arterial extracorporeal membrane oxygenation (ECMO) circuits, which may originate from the drainage cannula due to unfavorable blood flow dynamics. This study aims to numerically investigate the effect of cannula design parameters on local fluid dynamics, and thus thrombosis potential, within ECMO drainage cannulas. A control cannula based on the geometry of a 17 Fr Medtronic drainage cannula concentrically placed in an idealized, rigid-walled geometry of the right atrium and superior and inferior vena cava was numerically modeled. Simulated flow dynamics in the control cannula were systematically compared with 10 unique cannula designs which incorporated changes to side hole diameter, the spacing between side holes, and side hole angles. Local blood velocities, maximum wall shear stress (WSS), and blood residence time were used to predict the risk of thrombosis. Numerical results were experimentally validated using particle image velocimetry. The control cannula exhibited low blood velocities (59 mm/s) at the cannula tip, which may promote thrombosis. Through a reduction in the side hole diameter (2 mm), the spacing between the side holes (3 mm) and alteration in the side hole angle (30° relative to the flow direction), WSS was reduced by 52%, and cannula tip blood velocity was increased by 560% compared to the control cannula. This study suggests that simple geometrical changes can significantly alter the risk of thrombosis in ECMO drainage cannulas.
Collapse
Affiliation(s)
- Ashkan Vatani
- From the Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, Australia
- Baker Heart and Diabetes Institute, Melbourne, VIC, Australia
- Cardio-Respiratory Engineering and Technology Laboratory (CREATELab), Monash University, Clayton, VIC, Australia
| | - Sam Liao
- From the Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, Australia
- Baker Heart and Diabetes Institute, Melbourne, VIC, Australia
- Cardio-Respiratory Engineering and Technology Laboratory (CREATELab), Monash University, Clayton, VIC, Australia
| | - Aidan J C Burrell
- Department of Intensive Care and Hyperbaric Medicine, The Alfred Hospital, Melbourne, VIC, Australia
- School of Public Health and Preventive Medicine, Monash University, Melbourne, VIC, Australia
| | - Josie Carberry
- From the Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, Australia
| | - Marjan Azimi
- Baker Heart and Diabetes Institute, Melbourne, VIC, Australia
- Cardio-Respiratory Engineering and Technology Laboratory (CREATELab), Monash University, Clayton, VIC, Australia
| | - Ulrich Steinseifer
- From the Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, Australia
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Germany
- Chair of Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| | - Julio Soria
- Laboratory for Turbulence Research in Aerospace and Combustion ( LTRAC ), Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, Australia
| | - Vincent Pellegrino
- Department of Intensive Care and Hyperbaric Medicine, The Alfred Hospital, Melbourne, VIC, Australia
- School of Public Health and Preventive Medicine, Monash University, Melbourne, VIC, Australia
| | - David Kaye
- Baker Heart and Diabetes Institute, Melbourne, VIC, Australia
- The Department of Cardiology, The Alfred Hospital, Melbourne, VIC, Australia
| | - Shaun D Gregory
- From the Department of Mechanical and Aerospace Engineering, Monash University, Clayton, VIC, Australia
- Baker Heart and Diabetes Institute, Melbourne, VIC, Australia
- Cardio-Respiratory Engineering and Technology Laboratory (CREATELab), Monash University, Clayton, VIC, Australia
| |
Collapse
|
10
|
Steuer NB, Schlanstein PC, Hannig A, Sibirtsev S, Jupke A, Schmitz-Rode T, Kopp R, Steinseifer U, Wagner G, Arens J. Extracorporeal Hyperoxygenation Therapy (EHT) for Carbon Monoxide Poisoning: In-Vitro Proof of Principle. Membranes (Basel) 2021; 12:membranes12010056. [PMID: 35054581 PMCID: PMC8779470 DOI: 10.3390/membranes12010056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2021] [Accepted: 12/28/2021] [Indexed: 11/23/2022]
Abstract
Carbon monoxide (CO) poisoning is the leading cause of poisoning-related deaths globally. The currently available therapy options are normobaric oxygen (NBO) and hyperbaric oxygen (HBO). While NBO lacks in efficacy, HBO is not available in all areas and countries. We present a novel method, extracorporeal hyperoxygenation therapy (EHT), for the treatment of CO poisoning that eliminates the CO by treating blood extracorporeally at elevated oxygen partial pressure. In this study, we proof the principle of the method in vitro using procine blood: Firstly, we investigated the difference in the CO elimination of a hollow fibre membrane oxygenator and a specifically designed batch oxygenator based on the bubble oxygenator principle at elevated pressures (1, 3 bar). Secondly, the batch oxygenator was redesigned and tested for a broader range of pressures (1, 3, 5, 7 bar) and temperatures (23, 30, 37 °C). So far, the shortest measured carboxyhemoglobin half-life in the blood was 21.32 min. In conclusion, EHT has the potential to provide an easily available and effective method for the treatment of CO poisoning.
Collapse
Affiliation(s)
- Niklas B. Steuer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany; (P.C.S.); (A.H.); (U.S.); (G.W.); (J.A.)
- Correspondence: ; Tel.:+49-241-80-88764
| | - Peter C. Schlanstein
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany; (P.C.S.); (A.H.); (U.S.); (G.W.); (J.A.)
| | - Anke Hannig
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany; (P.C.S.); (A.H.); (U.S.); (G.W.); (J.A.)
| | - Stephan Sibirtsev
- Fluid Process Engineering (AVT.FVT), RWTH Aachen University, Forckenbeckstraße 51, 52074 Aachen, Germany; (S.S.); (A.J.)
| | - Andreas Jupke
- Fluid Process Engineering (AVT.FVT), RWTH Aachen University, Forckenbeckstraße 51, 52074 Aachen, Germany; (S.S.); (A.J.)
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany;
| | - Rüdger Kopp
- Department of Intensive Care Medicine, Medical Faculty, RWTH Aachen University, Pauwelsstraße 30, 52074 Aachen, Germany;
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany; (P.C.S.); (A.H.); (U.S.); (G.W.); (J.A.)
| | - Georg Wagner
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany; (P.C.S.); (A.H.); (U.S.); (G.W.); (J.A.)
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty, RWTH Aachen University, Pauwelsstraße 20, 52074 Aachen, Germany; (P.C.S.); (A.H.); (U.S.); (G.W.); (J.A.)
- Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, De Horst 2, 7522LW Enschede, The Netherlands
| |
Collapse
|
11
|
Clauser JC, Maas J, Mager I, Halfwerk FR, Arens J. The porcine abattoir blood model-Evaluation of platelet function for in-vitro hemocompatibility investigations. Artif Organs 2021; 46:922-931. [PMID: 34904246 DOI: 10.1111/aor.14146] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Revised: 10/21/2021] [Accepted: 12/07/2021] [Indexed: 11/30/2022]
Abstract
BACKGROUND The major obstacle of blood-contacting medical devices is insufficient hemocompatibility, particularly thrombogenicity and platelet activation. Pre-clinical in-vitro testing allows for the evaluation of adverse thrombogenicity-related events, but is limited, among others, by the availability and quantity of human blood donations. The use of animal blood is an accepted alternative for several tests; however, animal and particularly abattoir blood might present species-specific differences to human blood as well as elevated blood values, and pre-activated platelets due to stressed animals and non-standardized blood collection. MATERIAL & METHODS To this end, we investigated porcine abattoir blood in comparison to human donor blood with the focus on platelet pre-activation and remaining activation potential. By means of light transmission aggregometry, aggregation kinetics of platelet rich plasma after stimulation with three different concentrations of each adenosine diphosphate (ADP) (5 µM, 10 µM, 20 µM) and collagen (2.5 µg/ml, 5 µg/ml, 10 µg/ml) were monitored. RESULTS The activation with collagen revealed no significant differences in platelet behavior of the two species. In contrast, stimulation with ADP resulted in a lower maximum aggregation and a high disaggregation for porcine abattoir blood. The latter is a species-specific phenomenon of porcine platelets. Variations within each study cohort were comparable for human and abattoir pig. CONCLUSION The similarities in platelet activation following collagen stimulation and the preservation of the porcine-specific reaction to ADP prove a general functionality of the abattoir blood. This finding provides a first step towards the complete validation of the porcine abattoir blood model.
Collapse
Affiliation(s)
- Johanna C Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Judith Maas
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Ilona Mager
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Frank R Halfwerk
- Chair of Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands.,Thoraxcentrum Twente, Medisch Spectrum Twente, Enschede, The Netherlands
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.,Chair of Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| |
Collapse
|
12
|
Hesselmann F, Arnemann D, Bongartz P, Wessling M, Cornelissen C, Schmitz-Rode T, Steinseifer U, Jansen SV, Arens J. Three-dimensional membranes for artificial lungs: Comparison of flow-induced hemolysis. Artif Organs 2021; 46:412-426. [PMID: 34606117 DOI: 10.1111/aor.14081] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2021] [Revised: 08/11/2021] [Accepted: 09/22/2021] [Indexed: 11/29/2022]
Abstract
BACKGROUND Membranes based on triply periodic minimal surfaces (TPMS) have proven a superior gas transfer compared to the contemporary hollow fiber membrane (HFM) design in artificial lungs. The improved oxygen transfer is attributed to disrupting the laminar boundary layer adjacent to the membrane surface known as main limiting factor to mass transport. However, it requires experimental proof that this improvement is not at the expense of greater damage to the blood. Hence, the aim of this work is a valid statement regarding the structure-dependent hemolytic behavior of TPMS structures compared to the current HFM design. METHODS Hemolysis tests were performed on structure samples of three different kind of TPMS-based designs (Schwarz-P, Schwarz-D and Schoen's Gyroid) in direct comparison to a hollow fiber structure as reference. RESULTS The results of this study suggest that the difference in hemolysis between TPMS membranes compared to HFMs is small although slightly increased for the TPMS membranes. There is no significant difference between the TPMS structures and the hollow fiber design. Nevertheless, the ratio between the achieved additional oxygen transfer and the additional hemolysis favors the TPMS-based membrane shapes. CONCLUSION TPMS-shaped membranes offer a safe way to improve gas transfer in artificial lungs.
Collapse
Affiliation(s)
- Felix Hesselmann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Daniel Arnemann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Patrick Bongartz
- Chair of Chemical Process Engineering, RWTH Aachen University, Aachen, Germany
| | - Matthias Wessling
- Chair of Chemical Process Engineering, RWTH Aachen University, Aachen, Germany.,DWI-Leibniz Institute for Interactive Materials, RWTH Aachen University, Aachen, Germany
| | - Christian Cornelissen
- Department of Pneumology and Internal Intensive Care Medicine, Medical Clinic V, RWTH Aachen University Hospital, Aachen, Germany
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Sebastian Victor Jansen
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.,Chair of Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering, Technology University of Twente, Twente, The Netherlands
| |
Collapse
|
13
|
Kaesler A, Rudawski FL, Zander MO, Hesselmann F, Pinar I, Schmitz-Rode T, Arens J, Steinseifer U, Clauser JC. In-Vitro Visualization of Thrombus Growth in Artificial Lungs Using Real-Time X-Ray Imaging: A Feasibility Study. Cardiovasc Eng Technol 2021; 13:318-330. [PMID: 34532837 PMCID: PMC9114054 DOI: 10.1007/s13239-021-00579-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/27/2020] [Accepted: 09/03/2021] [Indexed: 01/10/2023]
Abstract
PURPOSE Extracorporeal membrane oxygenation has gained increasing attention in the treatment of patients with acute and chronic cardiopulmonary and respiratory failure. However, clotting within the oxygenators or other components of the extracorporeal circuit remains a major complication that necessitates at least a device exchange and bears risks of adverse events for the patients. In order to better predict thrombus growth within oxygenators, we present an approach for in-vitro visualization of thrombus growth using real-time X-ray imaging. METHODS An in-vitro test setup was developed using low-dose anticoagulated ovine blood and allowing for thrombus growth within 4 h. The setup was installed in a custom-made X-ray setup that uses phase-contrast for imaging, thus providing enhanced soft-tissue contrast, which improves the differentiation between blood and potential thrombus growth. During experimentation, blood samples were drawn for the analysis of blood count, activated partial thromboplastin time and activated clotting time. Additionally, pressure and flow data was monitored and a full 360° X-ray scan was performed every 15 min. RESULTS Thrombus formation indicated by a pressure drop and changing blood parameters was monitored in all three test devices. Red and white thrombi (higher/lower attenuation, respectively) were successfully segmented in one set of X-ray images. CONCLUSION We showed the feasibility of a new in-vitro method for real-time thrombus growth visualization by means of phase contrast X-ray imaging. In addition, with more blood parameters that are clinically relevant, this approach might contribute to improved oxygenator exchange protocols in the clinical routine.
Collapse
Affiliation(s)
- Andreas Kaesler
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Freya Lilli Rudawski
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Mark Oliver Zander
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Felix Hesselmann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Isaac Pinar
- Monash Institute of Medical Engineering and Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, Australia
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany.,Chair of Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, The Netherlands
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany.,Monash Institute of Medical Engineering and Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, Australia
| | - Johanna Charlotte Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University, Aachen, Germany.
| |
Collapse
|
14
|
Willers A, Arens J, Mariani S, Pels H, Maessen JG, Hackeng TM, Lorusso R, Swol J. New Trends, Advantages and Disadvantages in Anticoagulation and Coating Methods Used in Extracorporeal Life Support Devices. Membranes (Basel) 2021; 11:membranes11080617. [PMID: 34436380 PMCID: PMC8399034 DOI: 10.3390/membranes11080617] [Citation(s) in RCA: 23] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 08/06/2021] [Accepted: 08/08/2021] [Indexed: 11/16/2022]
Abstract
The use of extracorporeal life support (ECLS) devices has significantly increased in the last decades. Despite medical and technological advancements, a main challenge in the ECLS field remains the complex interaction between the human body, blood, and artificial materials. Indeed, blood exposure to artificial surfaces generates an unbalanced activation of the coagulation cascade, leading to hemorrhagic and thrombotic events. Over time, several anticoagulation and coatings methods have been introduced to address this problem. This narrative review summarizes trends, advantages, and disadvantages of anticoagulation and coating methods used in the ECLS field. Evidence was collected through a PubMed search and reference scanning. A group of experts was convened to openly discuss the retrieved references. Clinical practice in ECLS is still based on the large use of unfractionated heparin and, as an alternative in case of contraindications, nafamostat mesilate, bivalirudin, and argatroban. Other anticoagulation methods are under investigation, but none is about to enter the clinical routine. From an engineering point of view, material modifications have focused on commercially available biomimetic and biopassive surfaces and on the development of endothelialized surfaces. Biocompatible and bio-hybrid materials not requiring combined systemic anticoagulation should be the future goal, but intense efforts are still required to fulfill this purpose.
Collapse
Affiliation(s)
- Anne Willers
- ECLS Centre, Cardio-Thoracic Surgery, and Cardiology Department, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan 25, 6229 HX Maastricht, The Netherlands; (S.M.); (J.G.M.); (R.L.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
- Correspondence: (A.W.); (J.S.); Tel.: +31-(0)649-07-9752 (A.W.); +49-(911)-398-0 (J.S.)
| | - Jutta Arens
- Engineering Organ Support Technologies Group, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands; (J.A.); (H.P.)
| | - Silvia Mariani
- ECLS Centre, Cardio-Thoracic Surgery, and Cardiology Department, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan 25, 6229 HX Maastricht, The Netherlands; (S.M.); (J.G.M.); (R.L.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
| | - Helena Pels
- Engineering Organ Support Technologies Group, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, P.O. Box 217, 7500 AE Enschede, The Netherlands; (J.A.); (H.P.)
| | - Jos G. Maessen
- ECLS Centre, Cardio-Thoracic Surgery, and Cardiology Department, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan 25, 6229 HX Maastricht, The Netherlands; (S.M.); (J.G.M.); (R.L.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
| | - Tilman M. Hackeng
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
- Department of Biochemistry, Faculty of Health, Medicine and Life, Maastricht University, P.O. Box 616, 6200 MD Maastricht, The Netherlands
| | - Roberto Lorusso
- ECLS Centre, Cardio-Thoracic Surgery, and Cardiology Department, Heart & Vascular Centre, Maastricht University Medical Centre (MUMC), P. Debyelaan 25, 6229 HX Maastricht, The Netherlands; (S.M.); (J.G.M.); (R.L.)
- Cardiovascular Research Institute Maastricht (CARIM), Maastricht University, Universiteitssingel 50, 6229 ER Maastricht, The Netherlands;
| | - Justyna Swol
- Department of Respiratory Medicine, Allergology and Sleep Medicine, Paracelsus Medical University, Ernst-Nathan Str. 1, 90419 Nuremberg, Germany
- Correspondence: (A.W.); (J.S.); Tel.: +31-(0)649-07-9752 (A.W.); +49-(911)-398-0 (J.S.)
| |
Collapse
|
15
|
Fischbach A, Wiegand SB, Zazzeron L, Traeger L, di Fenza R, Bagchi A, Farinelli WA, Franco W, Korupolu S, Arens J, Grassi L, Zadek F, Bloch DB, Rox Anderson R, Zapol WM. Veno-venous extracorporeal blood phototherapy increases the rate of carbon monoxide (CO) elimination in CO-poisoned pigs. Lasers Surg Med 2021; 54:256-267. [PMID: 34350599 DOI: 10.1002/lsm.23462] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/18/2021] [Indexed: 11/09/2022]
Abstract
BACKGROUND AND OBJECTIVES Carbon monoxide (CO) inhalation is the leading cause of poison-related deaths in the United States. CO binds to hemoglobin (Hb), displaces oxygen, and reduces oxygen delivery to tissues. The optimal treatment for CO poisoning in patients with normal lung function is the administration of hyperbaric oxygen (HBO). However, hyperbaric chambers are only available in medical centers with specialized equipment, resulting in delayed therapy. Visible light dissociates CO from Hb with minimal effect on oxygen binding. In a previous study, we combined a membrane oxygenator with phototherapy at 623 nm to produce a "mini" photo-ECMO (extracorporeal membrane oxygenation) device, which improved CO elimination and survival in CO-poisoned rats. The objective of this study was to develop a larger photo-ECMO device ("maxi" photo-ECMO) and to test its ability to remove CO from a porcine model of CO poisoning. STUDY DESIGN/MATERIALS AND METHODS The "maxi" photo-ECMO device and the photo-ECMO system (six maxi photo-ECMO devices assembled in parallel), were tested in an in vitro circuit of CO poisoning. To assess the ability of the photo-ECMO device and the photo-ECMO system to remove CO from CO-poisoned blood in vitro, the half-life of COHb (COHb-t1/2 ), as well as the percent COHb reduction in a single blood pass through the device, were assessed. In the in vivo studies, we assessed the COHb-t1/2 in a CO-poisoned pig under three conditions: (1) While the pig breathed 100% oxygen through the endotracheal tube; (2) while the pig was connected to the photo-ECMO system with no light exposure; and (3) while the pig was connected to the photo-ECMO system, which was exposed to red light. RESULTS The photo-ECMO device was able to fully oxygenate the blood after a single pass through the device. Compared to ventilation with 100% oxygen alone, illumination with red light together with 100% oxygen was twice as efficient in removing CO from blood. Changes in gas flow rates did not alter CO elimination in one pass through the device. Increases in irradiance up to 214 mW/cm2 were associated with an increased rate of CO elimination. The photo-ECMO device was effective over a range of blood flow rates and with higher blood flow rates, more CO was eliminated. A photo-ECMO system composed of six photo-ECMO devices removed CO faster from CO-poisoned blood than a single photo-ECMO device. In a CO-poisoned pig, the photo-ECMO system increased the rate of CO elimination without significantly increasing the animal's body temperature or causing hemodynamic instability. CONCLUSION In this study, we developed a photo-ECMO system and demonstrated its ability to remove CO from CO-poisoned 45-kg pigs. Technical modifications of the photo-ECMO system, including the development of a compact, portable device, will permit treatment of patients with CO poisoning at the scene of their poisoning, during transit to a local emergency room, and in hospitals that lack HBO facilities.
Collapse
Affiliation(s)
- Anna Fischbach
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Steffen B Wiegand
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.,Department of Anesthesiology, University Hospital, LMU Munich, Munich, Germany
| | - Luca Zazzeron
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Lisa Traeger
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Raffaele di Fenza
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Aranya Bagchi
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - William A Farinelli
- Department of Dermatology, Massachusetts General Hospital and Harvard Medical School, Wellman Center for Photomedicine, Boston, Massachusetts, USA
| | - Walfre Franco
- Department of Biomedical Engineering, University of Massachusetts, Lowell, Massachusetts, USA
| | - Sandeep Korupolu
- Department of Dermatology, Massachusetts General Hospital and Harvard Medical School, Wellman Center for Photomedicine, Boston, Massachusetts, USA
| | - Jutta Arens
- Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Twente, The Netherlands
| | - Luigi Grassi
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Francesco Zadek
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - Donald B Bloch
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA.,Division of Rheumatology, Allergy, and Immunology, Department of Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| | - R Rox Anderson
- Department of Dermatology, Massachusetts General Hospital and Harvard Medical School, Wellman Center for Photomedicine, Boston, Massachusetts, USA
| | - Warren M Zapol
- Anesthesia Center for Critical Care Research of the Department of Anesthesia, Critical Care and Pain Medicine, Massachusetts General Hospital, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
16
|
Hesselmann F, Focke JM, Schlanstein PC, Steuer NB, Kaesler A, Reinartz SD, Schmitz-Rode T, Steinseifer U, Jansen SV, Arens J. Introducing 3D-potting: a novel production process for artificial membrane lungs with superior blood flow design. Biodes Manuf 2021. [DOI: 10.1007/s42242-021-00139-2] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
AbstractCurrently, artificial-membrane lungs consist of thousands of hollow fiber membranes where blood flows around the fibers and gas flows inside the fibers, achieving diffusive gas exchange. At both ends of the fibers, the interspaces between the hollow fiber membranes and the plastic housing are filled with glue to separate the gas from the blood phase. During a uniaxial centrifugation process, the glue forms the “potting.” The shape of the cured potting is then determined by the centrifugation process, limiting design possibilities and leading to unfavorable stagnation zones associated with blood clotting. In this study, a new multiaxial centrifugation process was developed, expanding the possible shapes of the potting and allowing for completely new module designs with potentially superior blood flow guidance within the potting margins. Two-phase simulations of the process in conceptual artificial lungs were performed to explore the possibilities of a biaxial centrifugation process and determine suitable parameter sets. A corresponding biaxial centrifugation setup was built to prove feasibility and experimentally validate four conceptual designs, resulting in good agreement with the simulations. In summary, this study shows the feasibility of a multiaxial centrifugation process allowing greater variety in potting shapes, eliminating inefficient stagnation zones and more favorable blood flow conditions in artificial lungs.
Graphic abstract
Collapse
|
17
|
Clauser JC, Maas J, Arens J, Schmitz-Rode T, Steinseifer U, Berkels B. Hemocompatibility Evaluation of Biomaterials-The Crucial Impact of Analyzed Area. ACS Biomater Sci Eng 2021; 7:553-561. [PMID: 33481566 DOI: 10.1021/acsbiomaterials.0c01589] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The hemocompatibility of blood-contacting medical devices remains one of the major challenges in medical device development. A common tool for the analysis of adherent and activated platelets on materials following in vitro tests is microscopy. Currently, most researchers develop their own routines, resulting in numerous different methods that are applied. The majority of those (semi-)manual methods analyze only a very small fraction of the material surface (<1%), which neglects the inhomogeneity of platelet distribution and makes results hardly comparable. Within this study, we examined the relation between the fraction of analyzed sample area and the platelet adhesion result. By means of image segmentation and machine learning algorithms, 103 100 microscopy images were analyzed automatically. We discovered a crucial impact of the analyzed surface fraction and thus a misrepresentation of a surface's platelet adhesion unless up to 40% of the sample surface is analyzed. These findings underline the necessity of standardization in the field of in vitro hemocompatibility tests and analyses in particular and provide a first basis to make future tests more reliable and comparable.
Collapse
Affiliation(s)
- Johanna C Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Judith Maas
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany.,Chair in Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr. 20, 52074 Aachen, Germany
| | - Benjamin Berkels
- AICES Graduate School, RWTH Aachen University, Schinkelstr. 2, 52062 Aachen, Germany.,Institute for Geometry and Practical Mathematics, RWTH Aachen University, Templergraben 55, 52056 Aachen, Germany
| |
Collapse
|
18
|
Abstract
Only a very small portion of end-stage organ failures can be treated by transplantation because of the shortage of donor organs. Although artificial long-term organ support such as ventricular assist devices provide therapeutic options serving as a bridge-to-transplantation or destination therapy for end-stage heart failure, suitable long-term artificial lung systems are still at an early stage of development. Although a short-term use of an extracorporeal lung support is feasible today, the currently available technical solutions do not permit the long-term use of lung replacement systems in terms of an implantable artificial lung. This is currently limited by a variety of factors: biocompatibility problems lead to clot formation within the system, especially in areas with unphysiological flow conditions. In addition, proteins, cells, and fibrin are deposited on the membranes, decreasing gas exchange performance and thus, limiting long-term use. Coordinated basic and translational scientific research to solve these problems is therefore necessary to enable the long-term use and implantation of an artificial lung. Strategies for improving the biocompatibility of foreign surfaces, for new anticoagulation regimes, for optimization of gas and blood flow, and for miniaturization of these systems must be found. These strategies must be validated by in vitro and in vivo tests, which remain to be developed. In addition, the influence of long-term support on the pathophysiology must be considered. These challenges require well-connected interdisciplinary teams from the natural and material sciences, engineering, and medicine, which take the necessary steps toward the development of an artificial implantable lung.
Collapse
Affiliation(s)
- Jutta Arens
- From the Chair in Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technologies, University of Twente, Enschede, The Netherlands
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty
| | - Oliver Grottke
- Department of Anesthesiology, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Axel Haverich
- Thoracic, Cardiac and Vascular Surgery, Medizinische Hochschule Hannover, Hannover, Germany
| | - Lars S. Maier
- Internal Medicine II, Universitätsklinikum Regensburg, Regensburg, Germany
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty
| | - H.P. Wendel
- Thoracic, Cardiac and Vascular Surgery, Universitätsklinikum Tübingen, Tübingen, Germany
| | - Rolf Rossaint
- Department of Anesthesiology, Medical Faculty, RWTH Aachen University, Aachen, Germany
| |
Collapse
|
19
|
Steuer NB, Hugenroth K, Beck T, Spillner J, Kopp R, Reinartz S, Schmitz-Rode T, Steinseifer U, Wagner G, Arens J. Long-Term Venovenous Connection for Extracorporeal Carbon Dioxide Removal (ECCO 2R)-Numerical Investigation of the Connection to the Common Iliac Veins. Cardiovasc Eng Technol 2020; 11:362-380. [PMID: 32405926 PMCID: PMC7385029 DOI: 10.1007/s13239-020-00466-y] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/18/2019] [Accepted: 05/02/2020] [Indexed: 02/06/2023]
Abstract
Purpose Currently used cannulae for extracorporeal carbon dioxide removal (ECCO2R) are associated with complications such as thrombosis and distal limb ischemia, especially for long-term use. We hypothesize that the risk of these complications is reducible by attaching hemodynamically optimized grafts to the patient’s vessels. In this study, as a first step towards a long-term stable ECCO2R connection, we investigated the feasibility of a venovenous connection to the common iliac veins. To ensure its applicability, the drainage of reinfused blood (recirculation) and high wall shear stress (WSS) must be avoided. Methods A reference model was selected for computational fluid dynamics, on the basis of the analysis of imaging data. Initially, a sensitivity analysis regarding recirculation was conducted using as variables: blood flow, the distance of drainage and return to the iliocaval junction, as well as the diameter and position of the grafts. Subsequently, the connection was optimized regarding recirculation and the WSS was evaluated. We validated the simulations in a silicone model traversed by dyed fluid. Results The simulations were in good agreement with the validation measurements (mean deviation 1.64%). The recirculation ranged from 32.1 to 0%. The maximum WSS did not exceed 5.57 Pa. The position and diameter of the return graft show the highest influence on recirculation. A correlation was ascertained between recirculation and WSS. Overall, an inflow jet directed at a vessel wall entails not only high WSS, but also a flow separation and thereby an increased recirculation. Therefore, return grafts aligned to the vena cava are crucial. Conclusion In conclusion, a connection without recirculation could be feasible and therefore provides a promising option for a long-term ECCO2R connection.
Collapse
Affiliation(s)
- N B Steuer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.
| | - K Hugenroth
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - T Beck
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - J Spillner
- Clinic for Cardiothoracic Surgery, University Hospital RWTH Aachen, Aachen, Germany
| | - R Kopp
- Department of Anesthesiology, University Hospital RWTH Aachen, Aachen, Germany
| | - S Reinartz
- Department of Radiology, University Hospital RWTH Aachen, Aachen, Germany
| | - T Schmitz-Rode
- Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - U Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - G Wagner
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany
| | - J Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Aachen, Germany.,Chair in Engineering Organ Support Technologies, Department of Biomechanical Engineering, Faculty of Engineering Technologies, University of Twente, Enschede, The Netherlands
| |
Collapse
|
20
|
Petran J, Muelly T, Dembinski R, Steuer N, Arens J, Marx G, Kopp R. Validation of RESP and PRESERVE score for ARDS patients with pumpless extracorporeal lung assist (pECLA). BMC Anesthesiol 2020; 20:102. [PMID: 32359363 PMCID: PMC7195797 DOI: 10.1186/s12871-020-01010-0] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2019] [Accepted: 04/15/2020] [Indexed: 11/29/2022] Open
Abstract
Background RESP score and PRESERVE score have been validated for veno-venous Extracorporeal Membrane Oxygenation in severe ARDS to assume individual mortality risk. ARDS patients with low-flow Extracorporeal Carbon Dioxide Removal, especially pumpless Extracorporeal Lung Assist, have also a high mortality rate, but there are no validated specific or general outcome scores. This retrospective study tested whether these established specific risk scores can be validated for pumpless Extracorporeal Lung Assist in ARDS patients in comparison to a general organ dysfunction score, the SOFA score. Methods In a retrospective single center cohort study we calculated and evaluated RESP, PRESERVE, and SOFA score for 73 ARDS patients with pumpless Extracorporeal Lung Assist treated between 2002 and 2016 using the XENIOS iLA Membrane Ventilator. Six patients had a mild, 40 a moderate and 27 a severe ARDS according to the Berlin criteria. Demographic data and hospital mortality as well as ventilator settings, hemodynamic parameters, and blood gas measurement before and during extracorporeal therapy were recorded. Results Pumpless Extracorporeal Lung Assist of mechanical ventilated ARDS patients resulted in an optimized lung protective ventilation, significant reduction of PaCO2, and compensation of acidosis. Scoring showed a mean score of alive versus deceased patients of 3 ± 1 versus − 1 ± 1 for RESP (p < 0.01), 3 ± 0 versus 6 ± 0 for PRESERVE (p < 0.05) and 8 ± 1 versus 10 ± 1 for SOFA (p < 0.05). Using receiver operating characteristic curves, area under the curve (AUC) was 0.78 (95% confidence interval (CI) 0.67–0.89, p < 0.01) for RESP score, 0.80 (95% CI 0.70–0.90, p < 0.0001) for PRESERVE score and 0.66 (95% CI 0.53–0.79, p < 0.05) for SOFA score. Conclusions RESP and PRESERVE scores were superior to SOFA, as non-specific critical care score. Although scores were developed for veno-venous ECMO, we could validate RESP and PRESERVE score for pumpless Extracorporeal Lung Assist. In conclusion, RESP and PRESERVE score are suitable to estimate mortality risk of ARDS patients with an arterio-venous pumpless Extracorporeal Carbon Dioxide Removal.
Collapse
Affiliation(s)
- Jan Petran
- Department of Intensive Care Medicine, Medical Faculty, RWTH Aachen University, Pauwelsstr 30, 52074, Aachen, Germany
| | - Thorsten Muelly
- Department of Anaesthesiology and Intensive Care Medicine, St. Antonius Hospital, Dechant-Deckers-Straße 8, 52249, Eschweiler, Germany
| | - Rolf Dembinski
- Clinic for Intensive Care and Emergency Medicine, Bremen-Mitte Hospital, Sankt-Jürgen-Straße 1, 28205, Bremen, Germany
| | - Niklas Steuer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr 20, 52074, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Medical Faculty, RWTH Aachen University, Pauwelsstr 20, 52074, Aachen, Germany.,Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Horst Complex, 7500 AE, Enschede, Netherlands
| | - Gernot Marx
- Department of Intensive Care Medicine, Medical Faculty, RWTH Aachen University, Pauwelsstr 30, 52074, Aachen, Germany
| | - Ruedger Kopp
- Department of Intensive Care Medicine, Medical Faculty, RWTH Aachen University, Pauwelsstr 30, 52074, Aachen, Germany.
| |
Collapse
|
21
|
Schöps M, Clauser JC, Menne MF, Faßbänder D, Schmitz-Rode T, Steinseifer U, Arens J. Ghost Cells for Mechanical Circulatory Support In Vitro Testing: A Novel Large Volume Production. Biotechnol J 2020; 15:e1900239. [PMID: 31904165 DOI: 10.1002/biot.201900239] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2018] [Revised: 12/10/2019] [Indexed: 11/09/2022]
Abstract
The aim of this work is to establish a large volume batch production system to produce sufficient volumes of ghost cells to facilitate hemolysis testing of mechanical circulatory support devices. A volume of more than 405 mL with a hematocrit of at least 28% is required to perform in vitro hemolysis testing of mechanical circulatory support devices according to international standards. The established ghost cell production method performed at the institute is limited to 3.1 mL of concentrated cells, that is, cells with 100% hematocrit, due to predominantly manual process steps. Through semi-automation of the existing method by using the large volume batch production system, productivity is increased 60-fold to 188 mL while almost doubling process efficiency to 23.5%. Time-consuming manual work such as pipetting is now supported by sensor-based process engineering. With the help of the large volume batch production system, the objective of producing large quantities of ghost cells is successfully achieved. Thus, this work lays the foundation for spatially resolved hemolysis evaluation of mechanical circulatory support devices in combination with the small-scale fluorescent hemolysis detection method.
Collapse
Affiliation(s)
- Malte Schöps
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Johanna C Clauser
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Matthias F Menne
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Dennis Faßbänder
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany.,Department of Mechanical and Aerospace Engineering, Monash Institute of Medical Engineering, Monash University, Clayton, VIC, 3800, Melbourne, Australia
| | - Jutta Arens
- Department of Cardiovascular Engineering , Institute of Applied Medical Engineering, RWTH Aachen University, 52074, Aachen, Germany
| |
Collapse
|
22
|
Klein M, Kuhn Y, Woelke E, Linde T, Ptock C, Kopp A, Bletek T, Schmitz‐Rode T, Steinseifer U, Arens J, Clauser JC. In vitro study on the hemocompatibility of plasma electrolytic oxidation coatings on titanium substrates. Artif Organs 2019; 44:419-427. [DOI: 10.1111/aor.13592] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2019] [Revised: 09/09/2019] [Accepted: 10/24/2019] [Indexed: 01/07/2023]
Affiliation(s)
- Mario Klein
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | - Yasmin Kuhn
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | - Eva Woelke
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | | | | | | | | | - Thomas Schmitz‐Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
- Department of Mechanical and Aerospace Engineering, Faculty of Engineering, Monash Institute of Medical Engineering Monash University Melbourne Australia
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| | - Johanna C. Clauser
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Medical Faculty RWTH Aachen University Aachen Germany
| |
Collapse
|
23
|
Gross-Hardt S, Hesselmann F, Arens J, Steinseifer U, Vercaemst L, Windisch W, Brodie D, Karagiannidis C. Low-flow assessment of current ECMO/ECCO 2R rotary blood pumps and the potential effect on hemocompatibility. Crit Care 2019; 23:348. [PMID: 31694688 PMCID: PMC6836552 DOI: 10.1186/s13054-019-2622-3] [Citation(s) in RCA: 50] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Accepted: 09/23/2019] [Indexed: 01/10/2023]
Abstract
Background Extracorporeal carbon dioxide removal (ECCO2R) uses an extracorporeal circuit to directly remove carbon dioxide from the blood either in lieu of mechanical ventilation or in combination with it. While the potential benefits of the technology are leading to increasing use, there are very real risks associated with it. Several studies demonstrated major bleeding and clotting complications, often associated with hemolysis and poorer outcomes in patients receiving ECCO2R. A better understanding of the risks originating specifically from the rotary blood pump component of the circuit is urgently needed. Methods High-resolution computational fluid dynamics was used to calculate the hemodynamics and hemocompatibility of three current rotary blood pumps for various pump flow rates. Results The hydraulic efficiency dramatically decreases to 5–10% if operating at blood flow rates below 1 L/min, the pump internal flow recirculation rate increases 6–12-fold in these flow ranges, and adverse effects are increased due to multiple exposures to high shear stress. The deleterious consequences include a steep increase in hemolysis and destruction of platelets. Conclusions The role of blood pumps in contributing to adverse effects at the lower blood flow rates used during ECCO2R is shown here to be significant. Current rotary blood pumps should be used with caution if operated at blood flow rates below 2 L/min, because of significant and high recirculation, shear stress, and hemolysis. There is a clear and urgent need to design dedicated blood pumps which are optimized for blood flow rates in the range of 0.5–1.5 L/min.
Collapse
Affiliation(s)
- Sascha Gross-Hardt
- Department of Cardiovascular Engineering, Medical Faculty, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Felix Hesselmann
- Department of Cardiovascular Engineering, Medical Faculty, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Medical Faculty, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Medical Faculty, Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany
| | - Leen Vercaemst
- Department of Perfusion, University Hospital Gasthuisberg, Leuven, Belgium
| | - Wolfram Windisch
- Department of Pneumology and Critical Care Medicine, Cologne-Merheim Hospital, ARDS and ECMO Center, Kliniken der Stadt Köln gGmbH, Witten/Herdecke University Hospital, Ostmerheimer Strasse 200, 51109, Cologne, Germany
| | - Daniel Brodie
- Center for Acute Respiratory Failure, Columbia University College of Physicians and Surgeons/New York-Presbyterian Hospital, New York, NY, USA
| | - Christian Karagiannidis
- Department of Pneumology and Critical Care Medicine, Cologne-Merheim Hospital, ARDS and ECMO Center, Kliniken der Stadt Köln gGmbH, Witten/Herdecke University Hospital, Ostmerheimer Strasse 200, 51109, Cologne, Germany.
| |
Collapse
|
24
|
Kiesendahl N, Schmitz C, Von Berg A, Menne M, Schmitz-Rode T, Arens J, Steinseifer U. In Vitro Calcification of Bioprosthetic Heart Valves: Investigation of Test Fluids. Ann Biomed Eng 2019; 48:282-297. [PMID: 31493168 DOI: 10.1007/s10439-019-02347-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2019] [Accepted: 08/16/2019] [Indexed: 10/26/2022]
Abstract
Calcification is a major reason for the failure of bioprosthetic heart valves. Therefore, several attempts towards an accelerated in vitro model were undertaken in order to provide a cost- and time-saving method for the analysis of calcification processes. Due to the problem of superficial or spontaneous precipitation, which occurred in the fluids applied, we focused our study on the development of a near-physiological calcification fluid. The desired fluid should not precipitate spontaneously and should neither promote nor inhibit calcification. Eleven different fluid compositions were tested without contact to potentially calcifying materials. Crucial factors regarding the fluid properties were the ionic product, the ionic strength, and the degree of supersaturation concerning dicalciumphosphate-dihydrate, octacalciumphosphate, and hydroxyapatite. The fluids were kept in polyethylene bottles and exposed to a slight vibration within a durability tester at 37 °C. The precipitation propensity was monitored optically and colorimetrically. A structural analysis of the deposits was carried out by x-ray powder diffraction and IR-spectroscopy, which showed the development of the crystal phases that are relevant in vivo. Only two of the fluids did not precipitate. Resulting from the computations of the effective fluid contents, the saturation degree concerning dicalciumphosphate-dihydrate seems to be the key factor for spontaneous precipitation.
Collapse
Affiliation(s)
- N Kiesendahl
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Aachen, Germany
| | - C Schmitz
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Aachen, Germany
| | - A Von Berg
- Institute of Crystallography, RWTH Aachen University, Aachen, Germany
| | - M Menne
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Aachen, Germany
| | - T Schmitz-Rode
- Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Pauwelsstraße 20, 52074, Aachen, Germany
| | - J Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Aachen, Germany
| | - U Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Aachen, Germany. .,Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Pauwelsstraße 20, 52074, Aachen, Germany. .,Monash Institute of Medical Engineering and Department of Mechanical and Aerospace Engineering, Monash University, Melbourne, Australia.
| |
Collapse
|
25
|
Diedrich M, Steinseifer U, Schmitz-Rode T, Risvanis F, Arens J, Kirn B. Reliability of left atrial pressure estimation from left ventricular filling measurement in a total artificial heart. Annu Int Conf IEEE Eng Med Biol Soc 2019; 2019:4905-4908. [PMID: 31946960 DOI: 10.1109/embc.2019.8857441] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
A physiological control of a total artificial heart (TAH) requires reliable information on left arterial pressure (LAP). When LAP is derived indirectly from intrinsic TAH parameters like end diastolic volume (EDV) and diastole duration (Td), the transfer function and associated uncertainties need to be well understood.We derived a computational equivalent to a hydraulic model consisting of the venous compliance, the heart valve and the pump chamber, and studied the filling phase in cases of different venous compliance. We calculated a family of curves of pump chamber volume as a function of time for different venous compliances and LAP. To visualize the LAP transfer function and uncertainties associated to EDV, Td measurement error and unknown venous compliance a family of similar curves in the vicinity of assumed measurement was found and visualised in the parameter space.Results were in a realistic absolute range and showed expected trends despite some simplifications in the simulation model. The venous compliance has no significant influence on LAP values extracted from EDV and Td, except at very low values. The uncertainty in the extracted LAP is particularly high for high EDV and short Td.A physiological regulation therefore does not have to be individually adapted to the patient's venous compliances, but has to deal with uncertainties in the input values like blood pressures extracted from intrinsic device parameters.
Collapse
|
26
|
Kaesler A, Hesselmann F, Zander MO, Schlanstein PC, Wagner G, Bruners P, Schmitz‐Rode T, Steinseifer U, Arens J. Technical Indicators to Evaluate the Degree of Large Clot Formation Inside the Membrane Fiber Bundle of an Oxygenator in an In Vitro Setup. Artif Organs 2018; 43:159-166. [DOI: 10.1111/aor.13343] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2018] [Revised: 07/05/2018] [Accepted: 07/11/2018] [Indexed: 12/19/2022]
Affiliation(s)
- Andreas Kaesler
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz Institute, RWTH Aachen University Aachen Germany
| | - Felix Hesselmann
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz Institute, RWTH Aachen University Aachen Germany
| | - Mark O. Zander
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz Institute, RWTH Aachen University Aachen Germany
| | - Peter C. Schlanstein
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz Institute, RWTH Aachen University Aachen Germany
| | - Georg Wagner
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz Institute, RWTH Aachen University Aachen Germany
| | - Philipp Bruners
- Clinic for Diagnostic and Interventional Radiology University Hospital RWTH Aachen Germany
| | - Thomas Schmitz‐Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz Institute, RWTH Aachen University Aachen Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz Institute, RWTH Aachen University Aachen Germany
- Department of Mechanical and Aerospace Engineering Monash Institute of Medical Engineering, Monash University Melbourne Australia
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering Helmholtz Institute, RWTH Aachen University Aachen Germany
| |
Collapse
|
27
|
Kaesler A, Rosen M, Schmitz-Rode T, Steinseifer U, Arens J. Computational Modeling of Oxygen Transfer in Artificial Lungs. Artif Organs 2018; 42:786-799. [DOI: 10.1111/aor.13146] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/21/2017] [Revised: 01/18/2018] [Accepted: 02/20/2018] [Indexed: 11/30/2022]
Affiliation(s)
- Andreas Kaesler
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Marius Rosen
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute; RWTH Aachen University; Aachen Germany
- Monash Institute of Medical Engineering and Department of Mechanical and Aerospace Engineering; Monash University; Melbourne Australia
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute; RWTH Aachen University; Aachen Germany
| |
Collapse
|
28
|
Schraven L, Kaesler A, Flege C, Kopp R, Schmitz-Rode T, Steinseifer U, Arens J. Effects of Pulsatile Blood Flow on Oxygenator Performance. Artif Organs 2018; 42:410-419. [DOI: 10.1111/aor.13088] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2017] [Revised: 11/01/2017] [Accepted: 11/02/2017] [Indexed: 11/30/2022]
Affiliation(s)
- Lotte Schraven
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering; RWTH Aachen University; Aachen Germany
| | - Andreas Kaesler
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering; RWTH Aachen University; Aachen Germany
| | - Christian Flege
- Department of Intensive Care; University Hospital, RWTH Aachen University; Aachen Germany
| | - Rüdger Kopp
- Department of Intensive Care; University Hospital, RWTH Aachen University; Aachen Germany
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering; RWTH Aachen University; Aachen Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering; RWTH Aachen University; Aachen Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering; RWTH Aachen University; Aachen Germany
| |
Collapse
|
29
|
Schlanstein PC, Limper A, Hesselmann F, Schmitz-Rode T, Steinseifer U, Arens J. Experimental method to determine anisotropic permeability of hollow fiber membrane bundles. J Memb Sci 2018. [DOI: 10.1016/j.memsci.2017.10.011] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
30
|
Bleilevens C, Grottke O, Groening S, Honickel M, Kopp R, Singh S, Arens J, Rossaint R. Septic porcine blood does not further activate coagulation during in vitro membrane oxygenation. Eur J Cardiothorac Surg 2017; 51:449-456. [PMID: 27806995 DOI: 10.1093/ejcts/ezw345] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Accepted: 09/16/2016] [Indexed: 11/12/2022] Open
Abstract
Objectives For patients with a severe acute respiratory distress syndrome (ARDS), extracorporeal membrane oxygenation (ECMO) represents a life-saving measure. Frequently, patients with severe ARDS also show signs of severe sepsis. As blood contact with the membrane oxygenator surface leads to adverse effects due to insufficient biocompatibility partly caused by activation of platelets, coagulation factors and leucocytes, we hypothesized that these adverse effects would be amplified if septic blood in a preactivated state came into contact with the membrane oxygenator. Methods In a previously established in vitro 12-h ECMO test system (mock loop), we used septic or healthy domestic pig blood to analyse coagulation and inflammatory parameters. Sepsis was induced by a caecal ligation and puncture model in pigs. Results At the beginning of the mock loop experiments, the septic blood showed significantly increased thrombin-antithrombin complexes (76.9 vs 27.7 µg/l), D-dimers (1.2 vs 0.3 mg/l) and fibrinogen concentration (1.8 vs 1.5 g/l), as well as elevated extrinsic coagulation activity (shorter EXTEM-CT: 44.2 vs 57 s) and higher lactate (3.4 vs 1.5 mmol/l) and cytokine levels (interleukin-6: 827 vs 31 pg/ml) when compared with the blood from healthy animals. Despite the preactivated status of the septic blood, no further increase of coagulation activity, inflammatory response or increased oxygenator resistance was observed in comparison to the control experiments. Conclusion Septic porcine blood was not further activated due to the contact with an oxygenator, and no increased clot formation or biocompatibility problems were observed.
Collapse
Affiliation(s)
- Christian Bleilevens
- Department of Anesthesiology, University Hospital RWTH Aachen University, Aachen, Germany
| | - Oliver Grottke
- Department of Anesthesiology, University Hospital RWTH Aachen University, Aachen, Germany
| | - Sabine Groening
- Department of Anesthesiology, University Hospital RWTH Aachen University, Aachen, Germany
| | - Markus Honickel
- Department of Anesthesiology, University Hospital RWTH Aachen University, Aachen, Germany
| | - Rüdger Kopp
- Department of Intensive Care, University Hospital RWTH Aachen University, Aachen, Germany
| | - Smriti Singh
- DWI-Leibniz-Institute for Interactive Materials, RWTH Aachen University, Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute Aachen, RWTH Aachen University, Aachen, Germany
| | - Rolf Rossaint
- Department of Anesthesiology, University Hospital RWTH Aachen University, Aachen, Germany
| |
Collapse
|
31
|
Kaesler A, Schlanstein PC, Hesselmann F, Büsen M, Klaas M, Roggenkamp D, Schmitz-Rode T, Steinseifer U, Arens J. Experimental Approach to Visualize Flow in a Stacked Hollow Fiber Bundle of an Artificial Lung With Particle Image Velocimetry. Artif Organs 2016; 41:529-538. [DOI: 10.1111/aor.12812] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2016] [Revised: 06/06/2016] [Accepted: 06/27/2016] [Indexed: 11/27/2022]
Affiliation(s)
- Andreas Kaesler
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University; Aachen Germany
| | - Peter C. Schlanstein
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University; Aachen Germany
| | - Felix Hesselmann
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University; Aachen Germany
| | - Martin Büsen
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University; Aachen Germany
| | - Michael Klaas
- Institute of Aerodynamics, RWTH Aachen University; Aachen Germany
| | | | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University; Aachen Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University; Aachen Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University; Aachen Germany
| |
Collapse
|
32
|
Wagner G, Kaesler A, Steinseifer U, Schmitz-Rode T, Arens J. Comment on "The promise of microfluidic artificial lungs" by J. A. Potkay, Lab Chip, 2014, 14, 4122-4138. Lab Chip 2016; 16:1272-1273. [PMID: 26956695 DOI: 10.1039/c5lc01508a] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/05/2023]
Abstract
This comment on an article that appeared in this journal (Potkay, Lab Chip, 2014, 14, 4122-4138) presents an alternative view on the feasibility and clinical application of current microfluidic artificial lungs.
Collapse
Affiliation(s)
- Georg Wagner
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany.
| | - Andreas Kaesler
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany.
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany.
| | - Thomas Schmitz-Rode
- Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering, Institute of Applied Medical Engineering, Helmholtz Institute, Pauwelsstraße 20, 52074 Aachen, Germany.
| |
Collapse
|
33
|
Cornelissen CG, Finocchiaro N, Arens J, Dreher M, Jockenhövel S. Leistungstest eines biohybriden Lungenunterstützungssystem. Pneumologie 2016. [DOI: 10.1055/s-0036-1571978] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
|
34
|
Kopp R, Bensberg R, Stollenwerk A, Arens J, Grottke O, Walter M, Rossaint R. Automatic Control of Veno-Venous Extracorporeal Lung Assist. Artif Organs 2016; 40:992-998. [DOI: 10.1111/aor.12664] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Ruedger Kopp
- Department of Intensive Care; University Hospital RWTH Aachen; Aachen Germany
| | - Ralf Bensberg
- Department of Intensive Care; University Hospital RWTH Aachen; Aachen Germany
| | - Andre Stollenwerk
- Informatik 11-Embedded Software; RWTH Aachen University; Aachen Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; RWTH Aachen University; Aachen Germany
| | - Oliver Grottke
- Department of Anaesthesiology; University Hospital RWTH Aachen; Aachen Germany
| | - Marian Walter
- Philips Chair for Medical Information Technology; RWTH Aachen University; Aachen Germany
| | - Rolf Rossaint
- Department of Intensive Care; University Hospital RWTH Aachen; Aachen Germany
- Department of Anaesthesiology; University Hospital RWTH Aachen; Aachen Germany
| |
Collapse
|
35
|
Schlanstein PC, Hesselmann F, Jansen SV, Gemsa J, Kaufmann TA, Klaas M, Roggenkamp D, Schröder W, Schmitz-Rode T, Steinseifer U, Arens J. Particle Image Velocimetry Used to Qualitatively Validate Computational Fluid Dynamic Simulations in an Oxygenator: A Proof of Concept. Cardiovasc Eng Technol 2015; 6:340-51. [DOI: 10.1007/s13239-015-0213-2] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2014] [Accepted: 01/16/2015] [Indexed: 12/01/2022]
|
36
|
Fiehe S, Wagner G, Schlanstein P, Rosefort C, Kopp R, Bensberg R, Knipp P, Schmitz-Rode T, Steinseifer U, Arens J. Implementation of quality management in early stages of research and development projects at a university. BIOMED ENG-BIOMED TE 2014; 59:135-45. [PMID: 24523303 DOI: 10.1515/bmt-2013-0085] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2013] [Accepted: 01/20/2014] [Indexed: 11/15/2022]
Abstract
The ultimate objective of university research and development projects is usually to create knowledge, but also to successfully transfer results to industry for subsequent marketing. We hypothesized that the university technology transfer requires efficient measures to improve this important step. Besides good scientific practice, foresighted and industry-specific adapted documentation of research processes in terms of a quality management system might improve the technology transfer. In order to bridge the gap between research institute and cooperating industry, a model project has been accompanied by a project specific amount of quality management. However, such a system had to remain manageable and must not constrain the researchers' creativity. Moreover, topics and research team are strongly interdisciplinary, which entails difficulties regarding communication because of different perspectives and terminology. In parallel to the technical work of the model project, an adaptable quality management system with a quality manual, defined procedures, and forms and documents accompanying the research, development and validation was implemented. After process acquisition and analysis the appropriate amount of management for the model project was identified by a self-developed rating system considering project characteristics like size, innovation, stakeholders, interdisciplinarity, etc. Employees were trained according to their needs. The management was supported and the technical documentation was optimized. Finally, the quality management system has been transferred successfully to further projects.
Collapse
|
37
|
Cornelissen CG, Engwicht S, Arens J, Jockenhoevel S. Biohybride Lungenunterstützungssysteme. Pneumologie 2014. [DOI: 10.1055/s-0034-1367768] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
38
|
Wagner G, Schlanstein P, Fiehe S, Kaufmann T, Kopp R, Bensberg R, Schmitz-Rode T, Steinseifer U, Arens J. A novel approach in extracorporeal circulation: individual, integrated, and interactive heart-lung assist (I3-Assist). ACTA ACUST UNITED AC 2014; 59:125-33. [DOI: 10.1515/bmt-2013-0026] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2013] [Accepted: 11/06/2013] [Indexed: 11/15/2022]
|
39
|
Schoberer M, Arens J, Erben A, Ophelders D, Jellema RK, Kramer BW, Bruse JL, Brouwer P, Schmitz-Rode T, Steinseifer U, Orlikowsky T. Miniaturization: The Clue to Clinical Application of the Artificial Placenta. Artif Organs 2013; 38:208-14. [DOI: 10.1111/aor.12146] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Affiliation(s)
- Mark Schoberer
- Neonatology Section of the Department of Paediatric and Adolescent Medicine; University Hospital; RWTH Aachen University; Aachen Germany
| | - Jutta Arens
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Aileen Erben
- Neonatology Section of the Department of Paediatric and Adolescent Medicine; University Hospital; RWTH Aachen University; Aachen Germany
| | - Daan Ophelders
- Department of Paediatrics; School of Mental Health and Neuroscience; School of Oncology and Developmental Biology; Maastricht University Medical Center; Maastricht The Netherlands
| | - Reint K. Jellema
- Department of Paediatrics; School of Mental Health and Neuroscience; School of Oncology and Developmental Biology; Maastricht University Medical Center; Maastricht The Netherlands
| | - Boris W. Kramer
- Department of Paediatrics; School of Mental Health and Neuroscience; School of Oncology and Developmental Biology; Maastricht University Medical Center; Maastricht The Netherlands
| | - Jan L. Bruse
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Petra Brouwer
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Thomas Schmitz-Rode
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Ulrich Steinseifer
- Department of Cardiovascular Engineering; Institute of Applied Medical Engineering; Helmholtz Institute; RWTH Aachen University; Aachen Germany
| | - Thorsten Orlikowsky
- Neonatology Section of the Department of Paediatric and Adolescent Medicine; University Hospital; RWTH Aachen University; Aachen Germany
| |
Collapse
|
40
|
Schnoering H, Arens J, Detering SM, Sachweh JS, Goetzenich A, Schmitz-Rode T, Steinseifer U, Vazquez-Jimenez JF. Expression of inflammation in myocardial tissue of rabbits: comparison of two miniaturized heart-lung machines. Artif Organs 2013; 37:541-8. [PMID: 23578310 DOI: 10.1111/aor.12025] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
The majority of cases involving the surgical treatment of congenital heart disease require implementation of cardiopulmonary bypass (CPB). However, neonates and infants are particularly prone to serious complications associated with CPB as a result of capillary leak due to cardiovascular failure. These complications are related to the transfusion of foreign blood, the disproportionately large area of contact between the patient's blood and foreign material, as well as the systemic inflammatory response induced by hemolysis. To attenuate these risks, we developed a novel, highly integrative, miniaturized heart-lung machine (MiniHLM) with a static priming volume of only 102 mL. This prototype was tested in comparison with a conventional heart-lung machine (static priming volume 213 mL) using a rabbit animal model. The animals were anesthetized, sternotomized, and connected to CBP via the aorta and right atrium. The aorta was cross-clamped for 1 h. Blood samples for examination were taken at regular intervals. Biopsies of the right atrial appendage (RAA) were removed directly after initiation and after cessation of CPB. After gradual reduction of perfusion with the HLM, all rabbits were successfully weaned from CPB, and the sternum was closed. Foreign blood was not administered in all cases. After cryopreservation of the RAA tissue, de novo transcription of inflammatory cytokines was measured by means of real-time polymerase chain reaction using the comparative CT method. No significant differences in the expression of the inflammatory parameters of the myocardial tissue samples were found between the study groups.
Collapse
Affiliation(s)
- Heike Schnoering
- Department of Pediatric Cardiac Surgery, Medical Faculty, RWTH Aachen University, Aachen, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
41
|
Schnoering H, Arens J, Detering SM, Stopinski T, Kuschel TJ, Tolba R, Steinseifer U, Vazquez-Jimenez JF. Development of a Rabbit Animal Model for Miniaturized Heart–Lung Machines. ASAIO J 2013; 59:152-6. [DOI: 10.1097/mat.0b013e3182857990] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
|
42
|
Schoberer M, Arens J, Lohr A, Seehase M, Jellema RK, Collins JJ, Kramer BW, Schmitz-Rode T, Steinseifer U, Orlikowsky T. Fifty years of work on the artificial placenta: milestones in the history of extracorporeal support of the premature newborn. Artif Organs 2012; 36:512-6. [PMID: 22309513 DOI: 10.1111/j.1525-1594.2011.01404.x] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
The concept of an artificial placenta has been pursued in experimental research since the early 1960s. The principle has yet to be successfully implemented in neonatal care despite the constant evolution in extracorporeal life support technology and advancements in neonatal intensive care in general. For more than three decades, the physical dimensions of the required equipment necessitated pump-driven circuits; however, recent advances in oxygenator technology have allowed exploration of the simpler and physiologically preferable concept of pumpless arteriovenous oxygenation. We expect that further miniaturization of the extracorporeal circuit will allow the implementation of the concept into clinical application as an assist device. To this end, NeonatOx (Fig. 1), a custom-made miniaturized oxygenator with a filling volume of 20 mL, designed by our own group, has been successfully implemented with a preterm lamb model of less than 2000 g body weight as an assist device. We provide an overview of milestones in the history of extracorporeal membrane oxygenation of the preterm newborn juxtaposed against current and future technological advancements. Key limitations, which need to be addressed in order to make mechanical gas exchange a clinical treatment option of prematurity-related lung failure, are also identified.
Collapse
Affiliation(s)
- Mark Schoberer
- Neonatology Section of the Department of Paediatric and Adolescent Medicine, University Hospital, RWTH Aachen, Pauwelsstrasse 30, Aachen, Germany.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
43
|
Arens J, Schoberer M, Lohr A, Orlikowsky T, Seehase M, Jellema RK, Collins JJ, Kramer BW, Schmitz-Rode T, Steinseifer U. NeonatOx: A Pumpless Extracorporeal Lung Support for Premature Neonates. Artif Organs 2011; 35:997-1001. [DOI: 10.1111/j.1525-1594.2011.01324.x] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
44
|
Walter M, Weyer S, Stollenwerk A, Kopp R, Arens J, Leonhardt S. A physiological model for extracorporeal oxygenation controller design. Annu Int Conf IEEE Eng Med Biol Soc 2011; 2010:434-7. [PMID: 21096765 DOI: 10.1109/iembs.2010.5627416] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Long term extracorporeal membrane oxygenation can be used in cases of severe lung failure to maintain sufficient gas exchange without the need to apply higher ventilation pressures which damage the lung additionally. The use of cardiopulmonary bypass devices is well established inside the operating room. The usage of such devices as long-term support in the intensive care unit is still experimental and limited to few cases. This is because neither machine architecture nor staff situation provides for the long term application scenario. In the joint research Project "smart ECLA" we target an advanced ECMO device featuring an automation system capable of maintaining gas concentrations automatically. One key requirement for systematic controller design is the availability of a process model, which will be presented in this article.
Collapse
Affiliation(s)
- Marian Walter
- Medical Information Technology, RWTH Aachen University, D-52074, Germany.
| | | | | | | | | | | |
Collapse
|
45
|
Graefe R, Borchardt R, Arens J, Schlanstein P, Schmitz-Rode T, Steinseifer U. Improving oxygenator performance using computational simulation and flow field-based parameters. Artif Organs 2011; 34:930-6. [PMID: 21092036 DOI: 10.1111/j.1525-1594.2010.01157.x] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Current goals in the development of oxygenators are to reduce extrinsic surface contact area, thrombus formation, hemolysis, and priming volume. To achieve these goals and provide a favorable concentration gradient for the gas exchange throughout the fiber bundle, this study attempts to find an optimized inlet and outlet port geometry to guide the flow of a hexagonal-shaped oxygenator currently under development. Parameters derived from numerical flow simulations allowed an automated quantitative evaluation of geometry changes of flow distribution plates. This led to a practical assessment of the quality of the flow. The results were validated qualitatively by comparison to flow visualization results. Two parameters were investigated, the first based on the velocity distribution and the second calculated from the residence time of massless particles representing erythrocytes. Both approaches showed significant potential to improve the flow pattern in the fiber bundle, based on one of the parameters of up to 66%. Computational fluid dynamics combined with a parameterization proved to be a powerful tool to quickly improve oxygenator designs.
Collapse
Affiliation(s)
- Roland Graefe
- Applied Medical Engineering, Helmholtz Institute, RWTH Aachen University, Aachen, Germany.
| | | | | | | | | | | |
Collapse
|
46
|
Borchardt R, Schlanstein P, Arens J, Graefe R, Schreiber F, Schmitz-Rode T, Steinseifer U. Description of a Flow Optimized Oxygenator With Integrated Pulsatile Pump. Artif Organs 2010; 34:904-10. [DOI: 10.1111/j.1525-1594.2010.01123.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
47
|
Schnoering H, Arens J, Terrada E, Sachweh JS, Runge M, Schmitz-Rode T, Steinseifer U, Vazquez-Jimenez JF. A Newly Developed Miniaturized Heart-Lung Machine-Expression of Inflammation in a Small Animal Model. Artif Organs 2010; 34:911-7. [DOI: 10.1111/j.1525-1594.2010.01146.x] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
48
|
Arens J, Schnoering H, Pfennig M, Mager I, Vázquez-Jiménez JF, Schmitz-Rode T, Steinseifer U. The Aachen MiniHLM-A Miniaturized Heart-Lung Machine for Neonates With an Integrated Rotary Blood Pump. Artif Organs 2010; 34:707-13. [DOI: 10.1111/j.1525-1594.2010.01082.x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
49
|
Schnoering H, Arens J, Sachweh JS, Veerman M, Tolba R, Schmitz-Rode T, Steinseifer U, Vazquez-Jimenez JF. The Aachen miniaturized heart-lung machine--first results in a small animal model. Artif Organs 2009; 33:935-40. [PMID: 19874283 DOI: 10.1111/j.1525-1594.2009.00935.x] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Congenital heart surgery most often incorporates extracorporeal circulation. Due to foreign surface contact and the administration of foreign blood in many children, inflammatory response and hemolysis are important matters of debate. This is particularly an issue in premature and low birth-weight newborns. Taking these considerations into account, the Aachen miniaturized heart-lung machine (MiniHLM) with a total static priming volume of 102 mL (including tubing) was developed and tested in a small animal model. Fourteen female Chinchilla Bastard rabbits were operated on using two different kinds of circuits. In eight animals, a conventional HLM with Dideco Kids oxygenator and Stöckert roller pump (Sorin group, Milan, Italy) was used, and the Aachen MiniHLM was employed in six animals. Outcome parameters were hemolysis and blood gas analysis including lactate. The rabbits were anesthetized, and a standard median sternotomy was performed. The ascending aorta and the right atrium were cannulated. After initiating cardiopulmonary bypass, the aorta was cross-clamped, and cardiac arrest was induced by blood cardioplegia. Blood samples for hemolysis and blood gas analysis were drawn before, during, and after cardiopulmonary bypass. After 1 h aortic clamp time, all animals were weaned from cardiopulmonary bypass. Blood gas analysis revealed adequate oxygenation and perfusion during cardiopulmonary bypass, irrespective of the employed perfusion system. The use of the Aachen MiniHLM resulted in a statistically significant reduced decrease in fibrinogen during cardiopulmonary bypass. A trend revealing a reduced increase in free hemoglobin during bypass in the MiniHLM group could also be observed. This newly developed Aachen MiniHLM with low priming volume, reduced hemolysis, and excellent gas transfer (O(2) and CO(2)) may reduce circuit-induced complications during heart surgery in neonates.
Collapse
Affiliation(s)
- Heike Schnoering
- Pediatric Cardiac Surgery, Medical Faculty, RWTH Aachen University, Aachen, Germany.
| | | | | | | | | | | | | | | |
Collapse
|
50
|
Oesch F, Oesch-Bartlomowicz B, Arens J, Fähndrich F, Vogel E, Friedberg T, Glatt H. Mechanism-based predictions of interactions. Environ Health Perspect 1994; 102 Suppl 9:5-9. [PMID: 7698085 PMCID: PMC1566774 DOI: 10.1289/ehp.94102s95] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [What about the content of this article? (0)] [Affiliation(s)] [Abstract] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Exposure to more than one toxic compound is common in real life. The resulting toxic effects are often more than the simple sum of the effects of the individual compounds. It is unlikely that it will ever be possible to test all combinations. It is therefore highly desirable to improve or develop means for reasonably approximating predictions of interactions. In order to be valid and extrapolatable, these predictions are most promising if they are mechanism-based. Examples will be given for possibilities of mechanism-based predictions of interactions which exceed trivialities of simple increases by enzyme induction of enzymatic rates of a given biotransformation pathway leading to a toxic metabolite. Instead, examples will be provided where competition between various enzymes for shunting the same substrate into divergent pathways can lead to predictable dramatic changes in toxicity by shifting the metabolic routes under conditions of no significant changes of overall metabolism. Further examples are given on predictable interactions between chemicals which need bioactivation for exerting their toxicity and chemicals which effect hormonal status and other endogenous factors which in turn modify enzymes involved in the control of toxic metabolites.
Collapse
Affiliation(s)
- F Oesch
- Institute of Toxicology, University of Mainz, Germany
| | | | | | | | | | | | | |
Collapse
|