1
|
Mahmud SZ, Gladden LB, Kavazis AN, Motl RW, Denney TS, Bashir A. Simultaneous Measurement of Perfusion and T 2* in Calf Muscle at 7T with Submaximal Exercise using Radial Acquisition. Sci Rep 2020; 10:6342. [PMID: 32286372 PMCID: PMC7156440 DOI: 10.1038/s41598-020-63009-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 03/19/2020] [Indexed: 11/09/2022] Open
Abstract
Impairments in oxygen delivery and consumption can lead to reduced muscle endurance and physical disability. Perfusion, a measure of microvascular blood flow, provides information on nutrient delivery. T2* provides information about relative tissue oxygenation. Changes in these parameters following stress, such as exercise, can yield important information about imbalance between delivery and consumption. In this study, we implemented novel golden angle radial MRI acquisition technique to simultaneously quantify muscle perfusion and T2* at 7T with improved temporal resolution, and demonstrated assessment of spatial and temporal changes in these parameters within calf muscles during recovery from plantar flexion exercise. Nine healthy subjects participated the studies. At rest, perfusion and T2* in gastrocnemius muscle group within calf muscle were 5 ± 2 mL/100 g/min and 21.1 ± 3 ms respectively. Then the subjects performed plantar flexion exercise producing a torque of ~8ft-lb. Immediately after the exercise, perfusion was elevated to 79.3 ± 9 mL/100 g/min and T2* was decreased by 6 ± 3%. The time constants for 50% perfusion and T2* recovery were 54.1 ± 10 s and 68.5 ± 7 s respectively. These results demonstrate successful simultaneous quantification of perfusion and T2* in skeletal muscle using the developed technique.
Collapse
Affiliation(s)
- Sultan Z Mahmud
- Department of Electrical and Computer Engineering, Auburn University, Auburn, AL, 36849, USA.
| | - L Bruce Gladden
- School of Kinesiology, Auburn University, Auburn, AL, 36849, USA
| | | | - Robert W Motl
- Department of Physical Therapy, University of Alabama at Birmingham, Birmingham, AL, 35294, USA
| | - Thomas S Denney
- Department of Electrical and Computer Engineering, Auburn University, Auburn, AL, 36849, USA
| | - Adil Bashir
- Department of Electrical and Computer Engineering, Auburn University, Auburn, AL, 36849, USA
| |
Collapse
|
2
|
Bane O, Mendichovszky IA, Milani B, Dekkers IA, Deux JF, Eckerbom P, Grenier N, Hall ME, Inoue T, Laustsen C, Lerman LO, Liu C, Morrell G, Pedersen M, Pruijm M, Sadowski EA, Seeliger E, Sharma K, Thoeny H, Vermathen P, Wang ZJ, Serafin Z, Zhang JL, Francis ST, Sourbron S, Pohlmann A, Fain SB, Prasad PV. Consensus-based technical recommendations for clinical translation of renal BOLD MRI. MAGMA (NEW YORK, N.Y.) 2020; 33:199-215. [PMID: 31768797 PMCID: PMC7021747 DOI: 10.1007/s10334-019-00802-x] [Citation(s) in RCA: 48] [Impact Index Per Article: 9.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 10/18/2019] [Accepted: 10/22/2019] [Indexed: 01/08/2023]
Abstract
Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.
Collapse
Affiliation(s)
- Octavia Bane
- BioMedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Iosif A Mendichovszky
- Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK
| | - Bastien Milani
- Center for BioMedical Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ilona A Dekkers
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jean-Francois Deux
- Department of Radiology, Groupe Hospitalier Henri Mondor, Créteil, France
| | - Per Eckerbom
- Department of Radiology, Institution for Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Nicolas Grenier
- Department of Radiology, Université de Bordeaux, CHU de Bordeaux, Bordeaux, France
| | - Michael E Hall
- Department of Medicine, University of Mississippi Medical Center, Jackson, MS, USA
| | - Tsutomu Inoue
- Department of Nephrology, Faculty of Medicine, Saitama Medical University, Saitama, Japan
| | - Christoffer Laustsen
- The MR Research Center Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Lilach O Lerman
- Division of Nephrology and Hypertension, Department of Internal Medicine, Mayo Clinic, Rochester, MN, USA
| | - Chunlei Liu
- Electrical Engineering and Computer Science, and Helen Wills Neuroscience Institute, University of California Berkeley, Berkeley, CA, USA
| | - Glen Morrell
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Michael Pedersen
- Department of Clinical Medicine-Comparative Medicine Lab, Aarhus University Hospital, Aarhus, Denmark
| | - Menno Pruijm
- Nephrology and Hypertension Service, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Elizabeth A Sadowski
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - Erdmann Seeliger
- Institute of Physiology, Charité-University Medicine Berlin, Berlin, Germany
| | - Kanishka Sharma
- Imaging Biomarkers Group, Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK
| | - Harriet Thoeny
- Department of Radiology, Hôpital Cantonal Fribourgois, University of Fribourg, Fribourg, Switzerland
| | - Peter Vermathen
- Departments for BioMedical Research and Radiology, Inselspital, Universitaetspital Bern, Bern, Switzerland
| | - Zhen J Wang
- Department of Radiology and Biomedical Imaging, University of California San Francisco Medical Center, San Francisco, CA, USA
| | - Zbigniew Serafin
- Department of Radiology, Nicolaus Copernicus University, Collegium Medicum, Bydgoszcz, Poland
| | - Jeff L Zhang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Susan T Francis
- Sir Peter Mansfield Centre, University of Notthingham, Notthingham, UK
| | - Steven Sourbron
- Imaging Biomarkers Group, Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Sean B Fain
- Departments of Biomedical Engineering, Radiology, and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Pottumarthi V Prasad
- Department of Radiology, Center for Advanced Imaging, NorthShore University Health System, Evanston, IL, USA.
| |
Collapse
|
3
|
Bane O, Mendichovszky IA, Milani B, Dekkers IA, Deux JF, Eckerbom P, Grenier N, Hall ME, Inoue T, Laustsen C, Lerman LO, Liu C, Morrell G, Pedersen M, Pruijm M, Sadowski EA, Seeliger E, Sharma K, Thoeny H, Vermathen P, Wang ZJ, Serafin Z, Zhang JL, Francis ST, Sourbron S, Pohlmann A, Fain SB, Prasad PV. Consensus-based technical recommendations for clinical translation of renal BOLD MRI. MAGMA (NEW YORK, N.Y.) 2019. [PMID: 31768797 DOI: 10.1007/s10334‐019‐00802‐x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Harmonization of acquisition and analysis protocols is an important step in the validation of BOLD MRI as a renal biomarker. This harmonization initiative provides technical recommendations based on a consensus report with the aim to move towards standardized protocols that facilitate clinical translation and comparison of data across sites. We used a recently published systematic review paper, which included a detailed summary of renal BOLD MRI technical parameters and areas of investigation in its supplementary material, as the starting point in developing the survey questionnaires for seeking consensus. Survey data were collected via the Delphi consensus process from 24 researchers on renal BOLD MRI exam preparation, data acquisition, data analysis, and interpretation. Consensus was defined as ≥ 75% unanimity in response. Among 31 survey questions, 14 achieved consensus resolution, 12 showed clear respondent preference (65-74% agreement), and 5 showed equal (50/50%) split in opinion among respondents. Recommendations for subject preparation, data acquisition, processing and reporting are given based on the survey results and review of the literature. These technical recommendations are aimed towards increased inter-site harmonization, a first step towards standardization of renal BOLD MRI protocols across sites. We expect this to be an iterative process updated dynamically based on progress in the field.
Collapse
Affiliation(s)
- Octavia Bane
- BioMedical Engineering and Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, NY, USA
| | - Iosif A Mendichovszky
- Department of Radiology, Cambridge University Hospitals NHS Foundation Trust, Cambridge University Hospitals NHS Foundation Trust, Addenbrooke's Hospital, Cambridge, UK
| | - Bastien Milani
- Center for BioMedical Imaging, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Ilona A Dekkers
- Department of Radiology, Leiden University Medical Center, Leiden, The Netherlands
| | - Jean-Francois Deux
- Department of Radiology, Groupe Hospitalier Henri Mondor, Créteil, France
| | - Per Eckerbom
- Department of Radiology, Institution for Surgical Sciences, Uppsala University, Uppsala, Sweden
| | - Nicolas Grenier
- Department of Radiology, Université de Bordeaux, CHU de Bordeaux, Bordeaux, France
| | - Michael E Hall
- Department of Medicine, University of Mississippi Medical Center, Jackson, MS, USA
| | - Tsutomu Inoue
- Department of Nephrology, Faculty of Medicine, Saitama Medical University, Saitama, Japan
| | - Christoffer Laustsen
- The MR Research Center Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Lilach O Lerman
- Division of Nephrology and Hypertension, Department of Internal Medicine, Mayo Clinic, Rochester, MN, USA
| | - Chunlei Liu
- Electrical Engineering and Computer Science, and Helen Wills Neuroscience Institute, University of California Berkeley, Berkeley, CA, USA
| | - Glen Morrell
- Department of Radiology and Imaging Sciences, University of Utah, Salt Lake City, UT, USA
| | - Michael Pedersen
- Department of Clinical Medicine-Comparative Medicine Lab, Aarhus University Hospital, Aarhus, Denmark
| | - Menno Pruijm
- Nephrology and Hypertension Service, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Elizabeth A Sadowski
- Department of Radiology, University of Wisconsin School of Medicine and Public Health, Madison, WI, USA
| | - Erdmann Seeliger
- Institute of Physiology, Charité-University Medicine Berlin, Berlin, Germany
| | - Kanishka Sharma
- Imaging Biomarkers Group, Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK
| | - Harriet Thoeny
- Department of Radiology, Hôpital Cantonal Fribourgois, University of Fribourg, Fribourg, Switzerland
| | - Peter Vermathen
- Departments for BioMedical Research and Radiology, Inselspital, Universitaetspital Bern, Bern, Switzerland
| | - Zhen J Wang
- Department of Radiology and Biomedical Imaging, University of California San Francisco Medical Center, San Francisco, CA, USA
| | - Zbigniew Serafin
- Department of Radiology, Nicolaus Copernicus University, Collegium Medicum, Bydgoszcz, Poland
| | - Jeff L Zhang
- Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Harvard Medical School, Boston, MA, USA
| | - Susan T Francis
- Sir Peter Mansfield Centre, University of Notthingham, Notthingham, UK
| | - Steven Sourbron
- Imaging Biomarkers Group, Department of Biomedical Imaging Sciences, University of Leeds, Leeds, UK
| | - Andreas Pohlmann
- Berlin Ultrahigh Field Facility, Max Delbrueck Center for Molecular Medicine in the Helmholtz Association, Berlin, Germany
| | - Sean B Fain
- Departments of Biomedical Engineering, Radiology, and Medical Physics, University of Wisconsin, Madison, WI, USA
| | - Pottumarthi V Prasad
- Department of Radiology, Center for Advanced Imaging, NorthShore University Health System, Evanston, IL, USA.
| |
Collapse
|
4
|
Gerhalter T, Carlier PG, Marty B. Acute changes in extracellular volume fraction in skeletal muscle monitored by 23Na NMR spectroscopy. Physiol Rep 2018; 5:5/16/e13380. [PMID: 28867674 PMCID: PMC5582265 DOI: 10.14814/phy2.13380] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2017] [Revised: 06/20/2017] [Accepted: 07/14/2017] [Indexed: 11/24/2022] Open
Abstract
In this article, we induced acute changes in extracellular volume fraction in skeletal muscle tissue and compared the sensitivity of a standard 1H T2 imaging method with different 23Na‐NMR spectroscopy parameters within acquisition times compatible with clinical investigations. First, we analyzed the effect of a short ischemia on the sodium distribution in the skeletal muscle. Then, the lower leg of 21 healthy volunteers was scanned under different vascular filling conditions (vascular draining, filling, and normal condition) expected to modify exclusively the extracellular volume. The first experiment showed no change in the total sodium content during a 15 min ischemia, but the intracellular weighted 23Na signal slowly decreased. For the second part, significant variations of total sodium content, sodium distribution, and T1 and T2∗ of 23Na signal were observed between different vascular filling conditions. The measured sodium distribution correlates significantly with sodium T1 and with the short and long T2∗ fractions. In contrast, significant changes in the proton T2w signal were observed only in three muscles. Altogether, the mean T2w signal intensity of all muscles as well as their mean T2 did not vary significantly with the extracellular volume changes. In conclusion, at the expense of giving up spatial resolution, the proposed 23Na spectroscopic method proved to be more sensitive than standard 1H T2 approach to monitor acute extracellular compartment changes within muscle tissue.
Collapse
Affiliation(s)
- Teresa Gerhalter
- Institute of Myology, NMR Laboratory, Paris, France .,CEA, DRF, IBFJ, MIRCen, NMR Laboratory, Paris, France
| | - Pierre G Carlier
- Institute of Myology, NMR Laboratory, Paris, France.,CEA, DRF, IBFJ, MIRCen, NMR Laboratory, Paris, France
| | - Benjamin Marty
- Institute of Myology, NMR Laboratory, Paris, France.,CEA, DRF, IBFJ, MIRCen, NMR Laboratory, Paris, France
| |
Collapse
|
5
|
Tierney J, Coolbaugh C, Towse T, Byram B. Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging. IEEE TRANSACTIONS ON MEDICAL IMAGING 2017; 36:1979-1991. [PMID: 28622670 PMCID: PMC5605932 DOI: 10.1109/tmi.2017.2714901] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
Conventional Doppler ultrasound is useful for visualizing fast blood flow in large resolvable vessels. However, frame rate and tissue clutter caused by movement of the patient or sonographer make visualizing slow flow with ultrasound difficult. Patient and sonographer motion causes spectral broadening of the clutter signal, which limits ultrasound's sensitivity to velocities greater than 5-10 mm/s for typical clinical imaging frequencies. To address this, we propose a clutter filtering technique that may increase the sensitivity of Doppler measurements to at least as low as 0.52 mm/s. The proposed technique uses plane wave imaging and an adaptive frequency and amplitude demodulation scheme to decrease the bandwidth of tissue clutter. To test the performance of the adaptive demodulation method at suppressing tissue clutter bandwidths due to sonographer hand motion alone, six volunteer subjects acquired data from a stationary phantom. Additionally, to test in vivo feasibility, arterial occlusion and muscle contraction studies were performed to assess the efficiency of the proposed filter at preserving signals from blood velocities 2 mm/s or greater at a 7.8 MHz center frequency. The hand motion study resulted in initial average bandwidths of 175 Hz (8.60mm/s), which were decreased to 10.5 Hz (0.52 mm/s) at -60 dB using our approach. The in vivo power Doppler studies resulted in 4.73 dB and 4.80 dB dynamic ranges of the blood flow with the proposed filter and 0.15 dB and 0.16 dB dynamic ranges of the blood flow with a conventional 50 Hz high-pass filter for the occlusion and contraction studies, respectively.
Collapse
|
6
|
Towse TF, Elder CP, Bush EC, Klockenkemper SW, Bullock JT, Dortch RD, Damon BM. Post-contractile BOLD contrast in skeletal muscle at 7 T reveals inter-individual heterogeneity in the physiological responses to muscle contraction. NMR IN BIOMEDICINE 2016; 29:1720-1728. [PMID: 27753155 PMCID: PMC6594689 DOI: 10.1002/nbm.3593] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2015] [Revised: 06/29/2016] [Accepted: 07/06/2016] [Indexed: 05/13/2023]
Abstract
Muscle blood oxygenation-level dependent (BOLD) contrast is greater in magnitude and potentially more influenced by extravascular BOLD mechanisms at 7 T than it is at lower field strengths. Muscle BOLD imaging of muscle contractions at 7 T could, therefore, provide greater or different contrast than at 3 T. The purpose of this study was to evaluate the feasibility of using BOLD imaging at 7 T to assess the physiological responses to in vivo muscle contractions. Thirteen subjects (four females) performed a series of isometric contractions of the calf muscles while being scanned in a Philips Achieva 7 T human imager. Following 2 s maximal isometric plantarflexion contractions, BOLD signal transients ranging from 0.3 to 7.0% of the pre-contraction signal intensity were observed in the soleus muscle. We observed considerable inter-subject variability in both the magnitude and time course of the muscle BOLD signal. A subset of subjects (n = 7) repeated the contraction protocol at two different repetition times (TR : 1000 and 2500 ms) to determine the potential of T1 -related inflow effects on the magnitude of the post-contractile BOLD response. Consistent with previous reports, there was no difference in the magnitude of the responses for the two TR values (3.8 ± 0.9 versus 4.0 ± 0.6% for TR = 1000 and 2500 ms, respectively; mean ± standard error). These results demonstrate that studies of the muscle BOLD responses to contractions are feasible at 7 T. Compared with studies at lower field strengths, post-contractile 7 T muscle BOLD contrast may afford greater insight into microvascular function and dysfunction.
Collapse
Affiliation(s)
- Theodore F. Towse
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Physical Medicine and Rehabilitation, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Christopher P. Elder
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Emily C. Bush
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Samuel W. Klockenkemper
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Jared T. Bullock
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Richard D. Dortch
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
| | - Bruce M. Damon
- Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Radiology and Radiological Sciences, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Biomedical Engineering, Vanderbilt University School of Engineering, Vanderbilt University Medical Center, Nashville, TN, USA
- Department of Molecular Physiology and Biophysics, Vanderbilt University School of Medicine, Vanderbilt University Medical Center, Nashville, TN, USA
| |
Collapse
|
7
|
Lin L, Yao J, Li L, Wang LV. In vivo photoacoustic tomography of myoglobin oxygen saturation. JOURNAL OF BIOMEDICAL OPTICS 2016; 21:61002. [PMID: 26719943 PMCID: PMC5397140 DOI: 10.1117/1.jbo.21.6.061002] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2015] [Accepted: 09/11/2015] [Indexed: 05/20/2023]
Abstract
Myoglobin is an essential oxygen-binding hemoprotein in skeletal and cardiac muscles that buffers intracellular oxygen (O2) concentration in response to hypoxia or elevated muscle activities. We present a method that uses photoacoustic computed tomography to measure the distribution of myoglobin in tissue and the oxygen saturation of myoglobin (sO2-Mb ). From photoacoustic measurements of mice in different oxygenation states, we performed calibration-free quantification of the sO2-Mb change in the backbone muscle in vivo.
Collapse
Affiliation(s)
- Li Lin
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, St. Louis, Missouri 63130, United States
| | - Junjie Yao
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, St. Louis, Missouri 63130, United States
| | - Lei Li
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, St. Louis, Missouri 63130, United States
| | - Lihong V. Wang
- Washington University in St. Louis, Department of Biomedical Engineering, Optical Imaging Laboratory, St. Louis, Missouri 63130, United States
- Address all correspondence to: Lihong V. Wang, E-mail:
| |
Collapse
|
8
|
Mathewson KW, Haykowsky MJ, Thompson RB. Feasibility and reproducibility of measurement of whole muscle blood flow, oxygen extraction, and VO2 with dynamic exercise using MRI. Magn Reson Med 2014; 74:1640-51. [PMID: 25533515 DOI: 10.1002/mrm.25564] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2014] [Revised: 10/17/2014] [Accepted: 11/14/2014] [Indexed: 11/08/2022]
Abstract
PURPOSE Develop an MRI method to estimate skeletal muscle oxygen consumption (VO2 ) with dynamic exercise using simultaneous measurement of venous blood flow (VBF) and venous oxygen saturation (SvO2 ). METHODS Real-time imaging of femoral VBF using a complex-difference method was interleaved with imaging of venous hemoglobin oxygen saturation (SvO2 ) using magnetic susceptometry to estimate muscle VO2 (Fick principle). Nine healthy subjects performed repeated 5-watt knee-extension (quadriceps) exercise within the bore of a 1.5 Tesla MRI scanner, for test/re-test comparison. VBF, SvO2 , and derived VO2 were estimated at baseline and immediately (<1 s) postexercise and every 2.4 s for 4 min. RESULTS Quadriceps muscle mass was 2.43 ± 0.31 kg. Mean baseline values were VBF = 0.13 ± 0.06 L/min/kg, SvO2 = 69.4 ± 10.1%, and VO2 = 6.8 ± 4.1 mL/min/kg. VBF, SvO2 , and VO2 values from peak exercise had good agreement between trials (VBF = 0.9 ± 0.1 versus 1.0 ± 0.1 L/min/kg, R(2) = 0.83, CV = 7.6%; SvO2 = 43.2 ± 13.5 versus 40.9 ± 13.1%, R(2) = 0.88, CV = 15.6%; VO2 = 95.7 ± 18.0 versus 108.9 ± 17.3 mL/min/kg, R(2) = 0.88, CV = 12.3%), as did the VO2 recovery time constant (26.1 ± 3.5 versus 26.0 ± 4.0 s, R(2) = 0.85, CV = 6.0%). CV = coefficient of variation. CONCLUSION Rapid imaging of VBF and SvO2 for the estimation of whole muscle VO2 is compatible with dynamic exercise for the estimation of peak values and recovery dynamics following exercise with good reproducibility.
Collapse
Affiliation(s)
- Kory W Mathewson
- Department of Biomedical Engineering, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Canada
| | - Mark J Haykowsky
- Faculty of Rehabilitation Medicine, University of Alberta, Edmonton, Canada
| | - Richard B Thompson
- Department of Biomedical Engineering, Faculty of Medicine and Dentistry, University of Alberta, Edmonton, Canada
| |
Collapse
|
9
|
Decorte N, Buehler T, Caldas de Almeida Araujo E, Vignaud A, Carlier PG. Noninvasive estimation of oxygen consumption in human calf muscle through combined NMR measurements of ASL perfusion and T₂ oxymetry. J Vasc Res 2014; 51:360-8. [PMID: 25531648 DOI: 10.1159/000368194] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2014] [Accepted: 09/03/2014] [Indexed: 11/19/2022] Open
Abstract
The objective of this work was to demonstrate the feasibility of measuring muscle O2 consumption (V˙O2) noninvasively with a combination of functional nuclear magnetic resonance (NMR) imaging methods, and to verify that changes in muscle V˙O2 can be detected with a temporal resolution compatible with physiological investigation and patient ease. T2-based oxymetry of arterial and venous blood was combined with the arterial-spin labeling (ASL)-based determination of muscle perfusion. These measurements were performed on 8 healthy volunteers under normoxic and hypoxic conditions in order to assess the sensitivity of measurements over a range of saturation values. Blood samples were drawn simultaneously and used to titrate blood T2 measurements versus hemoglobin O2 saturation (%HbO2) in vitro. The in vitro calibration curve of blood T2 fitted very well with the %HbO2 (r(2): 0.95). The in vivo venous T2 measurements agreed well with the in vitro measurements (intraclass correlation coefficient 0.82, 95% confidence interval 0.61-0.91). Oxygen extraction at rest decreased in the calf muscles subjected to hypoxia (p = 0.031). The combination of unaltered muscle perfusion and pinched arteriovenous O2 difference (p = 0.038) pointed towards a reduced calf muscle V˙O2 during transient hypoxia (p = 0.018). The results of this pilot study confirmed that muscle O2 extraction and V˙O2 can be estimated noninvasively using a combination of functional NMR techniques. Further studies are needed to confirm the usefulness in a larger sample of volunteers and patients.
Collapse
|
10
|
Vanhatalo A, Jones AM, Blackwell JR, Winyard PG, Fulford J. Dietary nitrate accelerates postexercise muscle metabolic recovery and O2 delivery in hypoxia. J Appl Physiol (1985) 2014; 117:1460-70. [PMID: 25301896 DOI: 10.1152/japplphysiol.00096.2014] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023] Open
Abstract
We tested the hypothesis that the time constants (τ) of postexercise T2* MRI signal intensity (an index of O2 delivery) and muscle [PCr] (an index of metabolic perturbation, measured by (31)P-MRS) in hypoxia would be accelerated after dietary nitrate (NO3 (-)) supplementation. In a double-blind crossover design, eight moderately trained subjects underwent 5 days of NO3 (-) (beetroot juice, BR; 8.2 mmol/day NO3 (-)) and placebo (PL; 0.003 mmol/day NO3 (-)) supplementation in four conditions: normoxic PL (N-PL), hypoxic PL (H-PL; 13% O2), normoxic NO3 (-) (N-BR), and hypoxic NO3 (-) (H-BR). The single-leg knee-extension protocol consisted of 10 min of steady-state exercise and 24 s of high-intensity exercise. The [PCr] recovery τ was greater in H-PL (30 ± 4 s) than H-BR (22 ± 4 s), N-PL (24 ± 4 s) and N-BR (22 ± 4 s) (P < 0.05) and the maximal rate of mitochondrial ATP resynthesis (Qmax) was lower in the H-PL (1.12 ± 0.16 mM/s) compared with H-BR (1.35 ± 0.26 mM/s), N-PL (1.47 ± 0.28 mM/s), and N-BR (1.40 ± 0.21 mM/s) (P < 0.05). The τ of postexercise T2* signal intensity was greater in H-PL (47 ± 14 s) than H-BR (32 ± 10 s), N-PL (38 ± 9 s), and N-BR (27 ± 6 s) (P < 0.05). The postexercise [PCr] and T2* recovery τ were correlated in hypoxia (r = 0.60; P < 0.05), but not in normoxia (r = 0.28; P > 0.05). These findings suggest that the NO3 (-)-NO2 (-)-NO pathway is a significant modulator of muscle energetics and O2 delivery during hypoxic exercise and subsequent recovery.
Collapse
Affiliation(s)
- Anni Vanhatalo
- College of Life and Environmental Sciences, St. Luke's Campus, University of Exeter, Exeter, United Kingdom;
| | - Andrew M Jones
- College of Life and Environmental Sciences, St. Luke's Campus, University of Exeter, Exeter, United Kingdom
| | - James R Blackwell
- College of Life and Environmental Sciences, St. Luke's Campus, University of Exeter, Exeter, United Kingdom
| | - Paul G Winyard
- University of Exeter Medical School, Exeter, United Kingdom, University of Exeter, Exeter, United Kingdom; and
| | - Jonathan Fulford
- NIHR Exeter Clinical Research Facility, University of Exeter Medical School, St. Luke's Campus, University of Exeter, Exeter, United Kingdom
| |
Collapse
|
11
|
Aschwanden M, Partovi S, Jacobi B, Fergus N, Schulte AC, Robbin MR, Bilecen D, Staub D. Assessing the end-organ in peripheral arterial occlusive disease-from contrast-enhanced ultrasound to blood-oxygen-level-dependent MR imaging. Cardiovasc Diagn Ther 2014; 4:165-72. [PMID: 24834413 DOI: 10.3978/j.issn.2223-3652.2014.03.02] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/03/2014] [Accepted: 02/26/2014] [Indexed: 11/14/2022]
Abstract
Peripheral arterial occlusive disease (PAOD) is a result of atherosclerotic disease which is currently the leading cause of morbidity and mortality in the western world. Patients with PAOD may present with intermittent claudication or symptoms related to critical limb ischemia. PAOD is associated with increased mortality rates. Stenoses and occlusions are usually detected by macrovascular imaging, including ultrasound and cross-sectional methods. From a pathophysiological view these stenoses and occlusions are affecting the microperfusion in the functional end-organs, such as the skin and skeletal muscle. In the clinical arena new imaging technologies enable the evaluation of the microvasculature. Two technologies currently under investigation for this purpose on the end-organ level in PAOD patients are contrast-enhanced ultrasound (CEUS) and blood-oxygen-level-dependent (BOLD) MR imaging (MRI). The following article is providing an overview about these evolving techniques with a specific focus on skeletal muscle microvasculature imaging in PAOD patients.
Collapse
Affiliation(s)
- Markus Aschwanden
- 1 University Hospital Basel, Department of Angiology, Basel, Switzerland ; 2 University Hospitals Case Medical Center, Case Western Reserve University, Department of Radiology, Cleveland, Ohio, USA ; 3 University Hospital Mainz, Department of Hematology & Oncology, Mainz, Germany ; 4 University Hospital Bruderholz, Department of Radiology, Bruderholz, Switzerland
| | - Sasan Partovi
- 1 University Hospital Basel, Department of Angiology, Basel, Switzerland ; 2 University Hospitals Case Medical Center, Case Western Reserve University, Department of Radiology, Cleveland, Ohio, USA ; 3 University Hospital Mainz, Department of Hematology & Oncology, Mainz, Germany ; 4 University Hospital Bruderholz, Department of Radiology, Bruderholz, Switzerland
| | - Bjoern Jacobi
- 1 University Hospital Basel, Department of Angiology, Basel, Switzerland ; 2 University Hospitals Case Medical Center, Case Western Reserve University, Department of Radiology, Cleveland, Ohio, USA ; 3 University Hospital Mainz, Department of Hematology & Oncology, Mainz, Germany ; 4 University Hospital Bruderholz, Department of Radiology, Bruderholz, Switzerland
| | - Nathan Fergus
- 1 University Hospital Basel, Department of Angiology, Basel, Switzerland ; 2 University Hospitals Case Medical Center, Case Western Reserve University, Department of Radiology, Cleveland, Ohio, USA ; 3 University Hospital Mainz, Department of Hematology & Oncology, Mainz, Germany ; 4 University Hospital Bruderholz, Department of Radiology, Bruderholz, Switzerland
| | - Anja-Carina Schulte
- 1 University Hospital Basel, Department of Angiology, Basel, Switzerland ; 2 University Hospitals Case Medical Center, Case Western Reserve University, Department of Radiology, Cleveland, Ohio, USA ; 3 University Hospital Mainz, Department of Hematology & Oncology, Mainz, Germany ; 4 University Hospital Bruderholz, Department of Radiology, Bruderholz, Switzerland
| | - Mark R Robbin
- 1 University Hospital Basel, Department of Angiology, Basel, Switzerland ; 2 University Hospitals Case Medical Center, Case Western Reserve University, Department of Radiology, Cleveland, Ohio, USA ; 3 University Hospital Mainz, Department of Hematology & Oncology, Mainz, Germany ; 4 University Hospital Bruderholz, Department of Radiology, Bruderholz, Switzerland
| | - Deniz Bilecen
- 1 University Hospital Basel, Department of Angiology, Basel, Switzerland ; 2 University Hospitals Case Medical Center, Case Western Reserve University, Department of Radiology, Cleveland, Ohio, USA ; 3 University Hospital Mainz, Department of Hematology & Oncology, Mainz, Germany ; 4 University Hospital Bruderholz, Department of Radiology, Bruderholz, Switzerland
| | - Daniel Staub
- 1 University Hospital Basel, Department of Angiology, Basel, Switzerland ; 2 University Hospitals Case Medical Center, Case Western Reserve University, Department of Radiology, Cleveland, Ohio, USA ; 3 University Hospital Mainz, Department of Hematology & Oncology, Mainz, Germany ; 4 University Hospital Bruderholz, Department of Radiology, Bruderholz, Switzerland
| |
Collapse
|
12
|
Schewzow K, Fiedler GB, Meyerspeer M, Goluch S, Laistler E, Wolzt M, Moser E, Schmid AI. Dynamic ASL and T2-weighted MRI in exercising calf muscle at 7 T: a feasibility study. Magn Reson Med 2014; 73:1190-5. [PMID: 24752959 DOI: 10.1002/mrm.25242] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2013] [Revised: 03/06/2014] [Accepted: 03/16/2014] [Indexed: 11/10/2022]
Abstract
PURPOSE The aim of this study was to develop a measurement protocol for noninvasive simultaneous perfusion quantification and T2 *-weighted MRI acquisition in the exercising calf muscle at 7 Tesla. METHODS Using a nonmagnetic ergometer and a dedicated in-house built calf coil array, dynamic pulsed arterial spin labeling (PASL) measurements with a temporal resolution of 12 s were performed before, during, and after plantar flexion exercise in 16 healthy volunteers. RESULTS Postexercise peak perfusion in gastrocnemius muscle (GAS) was 27 ± 16 ml/100g/min, whereas in soleus (SOL) and tibialis anterior (TA) muscles it remained at baseline levels. T2 *-weighted and ASL time courses in GAS showed comparable times to peak of 161 ± 72 s and 167 ± 115 s, respectively. The T2 *-weighted signal in the GAS showed a minimum during exercise (88 ± 6 % of the baseline signal) and a peak during the recovery (122 ± 9%), whereas in all other muscles only a signal decrease was observed (minimum 91 ± 6% in SOL; 87 ± 8% in TA). CONCLUSION We demonstrate the feasibility of dynamic perfusion quantification in skeletal muscle at 7 Tesla using PASL. This may help to better investigate the physiological processes in the skeletal muscle and also in diseases such as diabetes mellitus and peripheral arterial disease.
Collapse
Affiliation(s)
- Kiril Schewzow
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria; MR Centre of Excellence, Medical University of Vienna, Vienna, Austria
| | | | | | | | | | | | | | | |
Collapse
|
13
|
Englund EK, Langham MC, Li C, Rodgers ZB, Floyd TF, Mohler ER, Wehrli FW. Combined measurement of perfusion, venous oxygen saturation, and skeletal muscle T2* during reactive hyperemia in the leg. J Cardiovasc Magn Reson 2013; 15:70. [PMID: 23958293 PMCID: PMC3765712 DOI: 10.1186/1532-429x-15-70] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2013] [Accepted: 07/30/2013] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND The function of the peripheral microvascular may be interrogated by measuring perfusion, tissue oxygen concentration, or venous oxygen saturation (SvO2) recovery dynamics following induced ischemia. The purpose of this work is to develop and evaluate a magnetic resonance (MR) technique for simultaneous measurement of perfusion, SvO2, and skeletal muscle T2*. METHODS Perfusion, Intravascular Venous Oxygen saturation, and T2* (PIVOT) is comprised of interleaved pulsed arterial spin labeling (PASL) and multi-echo gradient-recalled echo (GRE) sequences. During the PASL post-labeling delay, images are acquired with a multi-echo GRE to quantify SvO2 and T2* at a downstream slice location. Thus time-courses of perfusion, SvO2, and T2* are quantified simultaneously within a single scan. The new sequence was compared to separately measured PASL or multi-echo GRE data during reactive hyperemia in five young healthy subjects. To explore the impairment present in peripheral artery disease patients, five patients were evaluated with PIVOT. RESULTS Comparison of PIVOT-derived data to the standard techniques shows that there was no significant bias in any of the time-course-derived metrics. Preliminary data show that PAD patients exhibited alterations in perfusion, SvO2, and T2* time-courses compared to young healthy subjects. CONCLUSION Simultaneous quantification of perfusion, SvO2, and T2* is possible with PIVOT. Kinetics of perfusion, SvO2, and T2* during reactive hyperemia may help to provide insight into the function of the peripheral microvasculature in patients with PAD.
Collapse
Affiliation(s)
- Erin K Englund
- Department of Radiology, Laboratory of Structural NMR Imaging, University of Pennsylvania Medical Center, 3400 Spruce Street, Philadelphia, PA 19104, USA
| | - Michael C Langham
- Department of Radiology, Laboratory of Structural NMR Imaging, University of Pennsylvania Medical Center, 3400 Spruce Street, Philadelphia, PA 19104, USA
| | - Cheng Li
- Department of Radiology, Laboratory of Structural NMR Imaging, University of Pennsylvania Medical Center, 3400 Spruce Street, Philadelphia, PA 19104, USA
| | - Zachary B Rodgers
- Department of Radiology, Laboratory of Structural NMR Imaging, University of Pennsylvania Medical Center, 3400 Spruce Street, Philadelphia, PA 19104, USA
| | - Thomas F Floyd
- Department of Anesthesiology, Stony Brook University Medical Center, Stony Brook, NY 11794, USA
| | - Emile R Mohler
- Department of Medicine, University of Pennsylvania School of Medicine, Philadelphia, PA 19104, USA
| | - Felix W Wehrli
- Department of Radiology, Laboratory of Structural NMR Imaging, University of Pennsylvania Medical Center, 3400 Spruce Street, Philadelphia, PA 19104, USA
| |
Collapse
|
14
|
|
15
|
Oxygenation and flow in the limbs: Novel methods to characterize peripheral artery disease. CURRENT CARDIOVASCULAR IMAGING REPORTS 2013; 6:150-157. [PMID: 23504569 DOI: 10.1007/s12410-013-9191-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Peripheral arterial disease (PAD) affects approximately 8 million Americans and is associated with high morbidity and increased mortality. Current therapies for PAD are limited and development of new therapeutic agents is needed. Present diagnostic methods for PAD are insensitive to the subtle microvascular and metabolic changes that occur beyond macrovacular stenosis and therefore may be less useful endpoints for clinical trials. Phosphorus-31 magnetic resonance (MR) spectroscopy, MR muscle perfusion, and MR oximetry are novel methods capable of evaluating both the macrovascular and microvascular changes that occur in PAD patients.
Collapse
|
16
|
Hallac RR, Ding Y, Yuan Q, McColl RW, Lea J, Sims RD, Weatherall PT, Mason RP. Oxygenation in cervical cancer and normal uterine cervix assessed using blood oxygenation level-dependent (BOLD) MRI at 3T. NMR IN BIOMEDICINE 2012; 25:1321-30. [PMID: 22619091 PMCID: PMC3445718 DOI: 10.1002/nbm.2804] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/27/2011] [Revised: 02/27/2012] [Accepted: 03/16/2012] [Indexed: 05/19/2023]
Abstract
Hypoxia is reported to be a biomarker for poor prognosis in cervical cancer. However, a practical noninvasive method is needed for the routine clinical evaluation of tumor hypoxia. This study examined the potential use of blood oxygenation level-dependent (BOLD) contrast MRI as a noninvasive technique to assess tumor vascular oxygenation at 3T. Following Institutional Review Board-approved informed consent and in compliance with the Health Insurance Portability and Accountability Act, successful results were achieved in nine patients with locally advanced cervical cancer [International Federation of Gynecology and Obstetrics (FIGO) stage IIA to IVA] and three normal volunteers. In the first four patients, dynamic T₂*-weighted MRI was performed in the transaxial plane using a multi-shot echo planar imaging sequence whilst patients breathed room air followed by oxygen (15 dm³/min). Later, a multi-echo gradient echo examination was added to provide quantitative R₂* measurements. The baseline T₂*-weighted signal intensity was quite stable, but increased to various extents in tumors on initiation of oxygen breathing. The signal in normal uterus increased significantly, whereas that in the iliacus muscle did not change. R₂* responded significantly in healthy uterus, cervix and eight cervical tumors. This preliminary study demonstrates that BOLD MRI of cervical cancer at 3T is feasible. However, more patients must be evaluated and followed clinically before any prognostic value can be determined.
Collapse
Affiliation(s)
- Rami R Hallac
- Department of Radiology, University of Texas Southwestern Medical Center, Dallas, TX, USA
| | | | | | | | | | | | | | | |
Collapse
|
17
|
Schewzow K, Andreas M, Moser E, Wolzt M, Schmid AI. Automatic model-based analysis of skeletal muscle BOLD-MRI in reactive hyperemia. J Magn Reson Imaging 2012; 38:963-9. [DOI: 10.1002/jmri.23919] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Affiliation(s)
- Kiril Schewzow
- MR Center of Excellence; Medical University of Vienna; Austria
- Department of Clinical Pharmacology; Medical University of Vienna; Austria
- Center of Medical Physics and Biomedical Engineering; Medical University of Vienna; Austria
| | - Martin Andreas
- Department of Clinical Pharmacology; Medical University of Vienna; Austria
- Department of Cardiac Surgery; Medical University of Vienna; Austria
| | - Ewald Moser
- MR Center of Excellence; Medical University of Vienna; Austria
- Center of Medical Physics and Biomedical Engineering; Medical University of Vienna; Austria
| | - Michael Wolzt
- Department of Clinical Pharmacology; Medical University of Vienna; Austria
| | - Albrecht I. Schmid
- MR Center of Excellence; Medical University of Vienna; Austria
- Center of Medical Physics and Biomedical Engineering; Medical University of Vienna; Austria
| |
Collapse
|
18
|
Partovi S, Karimi S, Jacobi B, Schulte AC, Aschwanden M, Zipp L, Lyo JK, Karmonik C, Müller-Eschner M, Huegli RW, Bongartz G, Bilecen D. Clinical implications of skeletal muscle blood-oxygenation-level-dependent (BOLD) MRI. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2012; 25:251-61. [PMID: 22374263 DOI: 10.1007/s10334-012-0306-y] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2011] [Revised: 01/31/2012] [Accepted: 02/01/2012] [Indexed: 01/24/2023]
Abstract
Blood-oxygenation-level-dependent (BOLD) contrast in magnetic resonance (MR) imaging of skeletal muscle mainly depends on changes of oxygen saturation in the microcirculation. In recent years, an increasing number of studies have evaluated the clinical relevance of skeletal muscle BOLD MR imaging in vascular diseases, such as peripheral arterial occlusive disease, diabetes mellitus, and chronic compartment syndrome. BOLD imaging combines the advantages of MR imaging, i.e., high spatial resolution, no exposure to ionizing radiation, with functional information of local microvascular perfusion. Due to intrinsic contrast provoked via changes in hemoglobin oxygen saturation, it is a safe and easy applicable procedure on standard whole-body MR devices. Therefore, BOLD MR imaging of skeletal muscle is a potential new diagnostic tool in the clinical evaluation of vascular, inflammatory, and muscular pathologies. Our review focuses on the current evidence concerning the use of BOLD MR imaging of skeletal muscle under pathological conditions and highlights ways for future clinical and scientific applications.
Collapse
Affiliation(s)
- Sasan Partovi
- Department of Radiology, University Hospital Bruderholz, Basel, Switzerland.
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
19
|
Winter JD, Estrada M, Cheng HLM. Normal tissue quantitative T1 and T2* MRI relaxation time responses to hypercapnic and hyperoxic gases. Acad Radiol 2011; 18:1159-67. [PMID: 21704536 DOI: 10.1016/j.acra.2011.04.016] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2010] [Revised: 04/19/2011] [Accepted: 04/29/2011] [Indexed: 11/25/2022]
Abstract
RATIONALE AND OBJECTIVES Longitudinal (T(1)) and effective transverse (T(2)*) magnetic resonance (MR) relaxation times provide noninvasive measures of tissue oxygenation. The objective for this study was to quantify independent effects of inhaled O(2) and CO(2) on normal tissue T(1) and T(2)* in rabbit liver, kidney, and paraspinal muscle. MATERIALS AND METHODS Three gas challenges (100% O(2), 10% CO(2) [balance air], and carbogen [90% O(2) + 10% CO(2)]) were delivered to the rabbits in random order to isolate the effects of inspired O(2) and CO(2). During each challenge, quantitative T(1) and T(2)* maps were collected on a 1.5 Tesla MR imaging. Mean changes in T(1) (ΔT(1)) and T(2)* (ΔT(2)*) were calculated from regions of interest in each organ. RESULTS Greatest ΔT(1) and ΔT(2)* changes were observed in liver for 10% CO(2) and in kidney for 100% O(2). ΔT(1) and ΔT(2)* generally followed predicted patterns when transitioning from air breathing: lower T(1)/higher T(2)* with inspired O(2), higher T(1)/lower T(2)* with inspired CO(2), and variable T(1)/T(2)* changes in the presence of both (ie, carbogen). New observations also emerged: 1) between-gas-challenge transitions revealed the greatest significance in ΔT(2)* for the liver and kidney resulting from the isolation of independent O(2) and CO(2) effects; 2) ΔT(2)* provided the best sensitivity and detected both tissue oxygenation and blood volume modulation; and 3) ΔT(1) sensitivity was restricted mainly to tissue oxygenation in the absence of counteracting vasodilatation. CONCLUSION Robust use of MR relaxation times as noninvasive biomarkers requires an understanding of their relative sensitivity to organ-specific physiological responses.
Collapse
|
20
|
Greve JM. BOLD MRI applied to a murine model of peripheral artery disease. Methods Mol Biol 2011; 771:511-30. [PMID: 21874496 DOI: 10.1007/978-1-61779-219-9_27] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/16/2023]
Abstract
Peripheral artery disease (PAD) is the narrowing or complete occlusion of vessels due to the progression of atherosclerosis. Ultimately, the reduction in blood supply, due to a reduced lumen diameter, results in a functional deficit, e.g., reduced mobility. Because function is closely tied to blood flow through large-caliber vessels, therapeutic development to treat PAD has recently focused on arteriogenesis rather than angiogenesis. Optimally, the preclinical investigations related to such therapeutic development would take place in murine models of PAD to allow for future studies utilizing transgenic strains. However, it can be challenging to quantify functional recovery of the peripheral vascular network in murine models. The purpose of this work is to provide a protocol of temporally and spatially resolved methods for functional assessment of arteriogenesis in a murine model.
Collapse
Affiliation(s)
- Joan M Greve
- Biomedical Imaging, Genentech, Inc., South San Francisco, CA 94080, USA.
| |
Collapse
|
21
|
de Sousa PL, Vignaud A, Fleury S, Carlier PG. Fast monitoring of T(1) , T(2) , and relative proton density (M(0) ) changes in skeletal muscles using an IR-TrueFISP sequence. J Magn Reson Imaging 2011; 33:921-30. [PMID: 21448959 DOI: 10.1002/jmri.22511] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
PURPOSE To investigate the feasibility of fast and simultaneous assessment of T(1) , T(2) , and M(0) (relative proton density) changes in skeletal muscle studies using an inversion recovery true fast imaging with steady-state precession (TrueFISP) sequence. MATERIALS AND METHODS NMR signal dynamics in calf muscles were analyzed under four different conditions: intravenous injection of a low-molecular weight Gd contrast agent (CA), postarterial occlusion reactive hyperemia, local cooling, and an exercise bout. Experiments were conducted on a clinical 3T whole-body scanner. RESULTS At rest, average muscle T(1) and T(2) values obtained from the IR-TrueFISP experiments were 1.34 ± 0.13 seconds and 45 ± 5 msec, respectively (median ± standard deviation). 1) Noticeable T(1) decreases (ΔT(1) max ≈-30%) were measured in the calf muscles after CA injection, while no significant changes were observed for T(2) and M(0) . 2) T(2) increased rapidly during reactive hyperemia and reached a peak value (+6%) at about 1 minute postischemia. During ischemia, a significant decrease was observed only in the soleus muscle. No significant paradigm-related changes in M(0) and T(1) were noted in all muscle groups, except in the m. soleus (ΔT(1) ≈+1% during reactive hyperemia). 3) Opposite variations in muscle T(1) (ΔT(1) max ≈-30%) and M(0) (ΔM(0) max ≈+25%) associated with local cooling were detected. 4) Concomitant changes in T(1) (ΔT(1) max ≈+15%), T(2) (ΔT(2) max ≈+35%), and M(0) (ΔM(0) max ≈+16%) were observed in the activated muscles following the exercise bout. CONCLUSION IR-TrueFISP was sufficiently fast and sensitive to detect small and transient T(1) , T(2) , and M(0) changes in the calf muscles under different experimental conditions. The sequence offers a time-resolution adequate to track rapid physiological adaptations in skeletal muscle.
Collapse
|
22
|
Andreas M, Schmid AI, Keilani M, Doberer D, Bartko J, Crevenna R, Moser E, Wolzt M. Effect of ischemic preconditioning in skeletal muscle measured by functional magnetic resonance imaging and spectroscopy: a randomized crossover trial. J Cardiovasc Magn Reson 2011; 13:32. [PMID: 21718491 PMCID: PMC3143996 DOI: 10.1186/1532-429x-13-32] [Citation(s) in RCA: 62] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2011] [Accepted: 06/30/2011] [Indexed: 12/21/2022] Open
Abstract
BACKGROUND Nuclear magnetic resonance (NMR) imaging and spectroscopy have been applied to assess skeletal muscle oxidative metabolism. Therefore, in-vivo NMR may enable the characterization of ischemia-reperfusion injury. The goal of this study was to evaluate whether NMR could detect the effects of ischemic preconditioning (IPC) in healthy subjects. METHODS Twenty-three participants were included in two randomized crossover protocols in which the effects of IPC were measured by NMR and muscle force assessments. Leg ischemia was administered for 20 minutes with or without a subsequent impaired reperfusion for 5 minutes (stenosis model). IPC was administered 4 or 48 hours prior to ischemia. Changes in 31phosphate NMR spectroscopy and blood oxygen level-dependent (BOLD) signals were recorded. 3-Tesla NMR data were compared to those obtained for isometric muscular strength. RESULTS The phosphocreatine (PCr) signal decreased robustly during ischemia and recovered rapidly during reperfusion. In contrast to PCr, the recovery of muscular strength was slow. During post-ischemic stenosis, PCr increased only slightly. The BOLD signal intensity decreased during ischemia, ischemic exercise and post-ischemic stenosis but increased during hyperemic reperfusion. IPC 4 hours prior to ischemia significantly increased the maximal PCr reperfusion signal and mitigated the peak BOLD signal during reperfusion. CONCLUSIONS Ischemic preconditioning positively influenced muscle metabolism during reperfusion; this resulted in an increase in PCr production and higher oxygen consumption, thereby mitigating the peak BOLD signal. In addition, an impairment of energy replenishment during the low-flow reperfusion was detected in this model. Thus, functional NMR is capable of characterizing changes in reperfusion and in therapeutic interventions in vivo. TRIAL REGISTRATION ClinicalTrials.gov: NCT00883467.
Collapse
Affiliation(s)
- Martin Andreas
- Department of Clinical Pharmacology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Albrecht I Schmid
- Department of Clinical Pharmacology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
- MR Center of Excellence, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Mohammad Keilani
- Department of Physical Medicine and Rehabilitation, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Daniel Doberer
- Department of Clinical Pharmacology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Johann Bartko
- Department of Clinical Pharmacology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Richard Crevenna
- Department of Physical Medicine and Rehabilitation, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Ewald Moser
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
- MR Center of Excellence, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| | - Michael Wolzt
- Department of Clinical Pharmacology, Medical University of Vienna, Waehringer Guertel 18-20, A-1090 Vienna, Austria
| |
Collapse
|
23
|
Functional imaging in muscular diseases. Insights Imaging 2011; 2:609-619. [PMID: 22347980 PMCID: PMC3259416 DOI: 10.1007/s13244-011-0111-6] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2011] [Revised: 04/10/2011] [Accepted: 06/09/2011] [Indexed: 12/21/2022] Open
Abstract
OBJECTIVE: The development of morphological and functional imaging techniques has improved the diagnosis of muscular disorders. METHODS: With the use of whole-body magnetic resonance imaging (MRI) the possibility of imaging the entire body has been introduced. In patients with suspected myositis, oedematous and inflammatory changed muscles can be sufficiently depicted and therefore biopsies become more precise. RESULTS: Functional MR methods visualise different aspects of muscular (patho)physiology: muscular sodium (Na(+)) homeostasis can be monitored with (23)Na MRI; the muscular energy and lipid metabolism can be monitored using (31)P and (1)H MR spectroscopy. (23)Na MRI has reached an acceptable value in the diagnosis and follow-up of patients with muscular Na(+) channelopathies that are characterised by myocellular Na(+) overload and consecutive muscle weakness. Besides MRI, low mechanical index contrast-enhanced ultrasound (CEUS) methods have also been introduced. For evaluation of myositis, CEUS is more efficient in the diagnostic work-up than usual b-mode ultrasound, because CEUS can detect the inflammatory-induced muscular hyperperfusion in acute myositis. Moreover, the arterial perfusion reserve in peripheral arterial disease can be adequately examined using CEUS. CONCLUSION: Modern muscular imaging techniques offer deeper insights in muscular (patho)physiology than just illustrating unspecific myopathic manifestations like oedematous or lipomatous changes, hypertrophy or atrophy.
Collapse
|
24
|
Towse TF, Slade JM, Ambrose JA, DeLano MC, Meyer RA. Quantitative analysis of the postcontractile blood-oxygenation-level-dependent (BOLD) effect in skeletal muscle. J Appl Physiol (1985) 2011; 111:27-39. [PMID: 21330621 DOI: 10.1152/japplphysiol.01054.2009] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Previous studies show that transient increases in both blood flow and magnetic resonance image signal intensity (SI) occur in human muscle after brief, single contractions, and that the SI increases are threefold larger in physically active compared with sedentary subjects. This study examined the relationship between these transient changes by measuring anterior tibial artery flow (Doppler ultrasound), anterior muscle SI (3T, one-shot echo-planar images, TR/TE = 1,000/35), and muscle blood volume and hemoglobin saturation [near-infrared spectroscopy (NIRS)] in the same subjects after 1-s-duration maximum isometric ankle dorsiflexion contractions. Arterial flow increased to a peak 5.9 ± 0.7-fold above rest (SE, n = 11, range 2.6-10.2) within 7 s and muscle SI increased to a peak 2.7 ± 0.6% (range 0.0-6.0%) above rest within 12 s after the contractions. The peak postcontractile SI change was significantly correlated with both peak postcontractile flow (r = 0.61, n = 11) and with subject activity level (r = 0.63, n = 10) estimated from 7-day accelerometer recordings. In a subset of 7 subjects in which NIRS data acquisition was successful, the peak magnitude of the postcontractile SI change agreed well with SI calculated from the NIRS blood volume and saturation changes (r = 0.80, slope = 1.02, intercept = 0.16), confirming the blood-oxygenation-level-dependent (BOLD) mechanism underlying the SI change. The magnitudes of postcontractile changes in blood saturation and SI were reproduced by a simple one-compartment muscle vascular model that incorporated the observed pattern of postcontractile flow, and which assumed muscle O(2) consumption peaks within 2 s after a brief contraction. The results show that muscle postcontractile BOLD SI changes depend critically on the balance between O(2) delivery and O(2) consumption, both of which can be altered by chronic physical activity.
Collapse
Affiliation(s)
- Theodore F Towse
- Department of Physiology, Michigan State University, East Lansing, MI 48824, USA
| | | | | | | | | |
Collapse
|
25
|
Abstract
The purpose of this chapter is to introduce the novice NMR imager to blood oxygen level dependent (BOLD) contrast as well as remind the seasoned veteran of its beauty. Introduction to many of the factors that influence the BOLD signal is given higher priority than pursuing any subset in exquisite detail. Instead, references are given for readers seeking intense investigations into a given aspect. The hope is that this overview inspires the reader with the elegant simplicity of BOLD contrast while not, at first, intimidating too much with the underlying complexity. As one's knowledge of NMR matures so too will one's understanding, appreciation, and application of BOLD MRI. BOLD contrast derives from variations in the magnetic susceptibility of blood due to variations in the concentration of deoxyhemoglobin. These magnetic susceptibility effects produce local magnetic fields around blood vessels that can result in phase dispersion of nearby spins and, therefore, changes in signal intensity in NMR images. After providing brief historical context for BOLD, this chapter will follow the trail of magnetic susceptibility through definition, its source and location in vivo, and how the source and location in vivo interact with anatomical (e.g., blood vessel size) and imaging considerations (e.g., pulse sequence) to influence the BOLD signal. We will conclude by briefly highlighting clinical and preclinical applications using BOLD contrast.
Collapse
Affiliation(s)
- Joan M Greve
- Biomedical Imaging, Genentech, Inc., South San Francisco, CA 94080, USA.
| |
Collapse
|
26
|
Wu WC, Mohler E, Ratcliffe SJ, Wehrli FW, Detre JA, Floyd TF. Skeletal muscle microvascular flow in progressive peripheral artery disease: assessment with continuous arterial spin-labeling perfusion magnetic resonance imaging. J Am Coll Cardiol 2009; 53:2372-7. [PMID: 19539149 DOI: 10.1016/j.jacc.2009.03.033] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/02/2008] [Revised: 02/24/2009] [Accepted: 03/10/2009] [Indexed: 11/24/2022]
Abstract
OBJECTIVES We present the novel application of continuous arterial spin-labeling (CASL) magnetic resonance imaging (MRI) for the measurement of calf muscle perfusion in subjects with progressive peripheral arterial disease (PAD). BACKGROUND Peripheral arterial disease is largely considered to be a disease of conduit vessels. The impact of PAD upon microvascular flow in the end-organ, muscle, remains unknown. Continuous arterial spin-labeling is a noninvasive MRI method capable of measuring microvascular flow and might assist in our understanding of the impact of PAD upon the microvasculature. METHODS Forty subjects with varying degrees of PAD and 17 age-matched PAD-free subjects were recruited and underwent measurement of the ankle-to-brachial index (ABI) and CASL. Peak hyperemic flow (PHF) and time-to-peak (TTP) were computed and assessed as a function of ABI and calf muscle group. RESULTS An ABI dependence was found in both PHF (p = 0.04) and TTP (p < 10(-4)). Whereas TTP increased almost immediately with increasing PAD severity, PHF was, in contrast, relatively well preserved until later stages of disease. CONCLUSIONS The CASL flow measurements correlate with disease state as measured by ABI and demonstrate preserved microvascular flow reserve in the presence of early to intermediate vascular disease.
Collapse
Affiliation(s)
- Wen-Chau Wu
- Department of Radiology, Hospital of University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA
| | | | | | | | | | | |
Collapse
|
27
|
Greve JM, Williams SP, Bernstein LJ, Goldman H, Peale FV, Bunting S, van Bruggen N. Reactive hyperemia and BOLD MRI demonstrate that VEGF inhibition, age, and atherosclerosis adversely affect functional recovery in a murine model of peripheral artery disease. J Magn Reson Imaging 2009; 28:996-1004. [PMID: 18821600 DOI: 10.1002/jmri.21517] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
PURPOSE To develop magnetic resonace imaging (MRI) methods for functional assessment of arteriogenesis in a murine model of peripheral artery disease to quantify the influences of vascular endothelial growth factor (VEGF), age, and atherosclerosis. MATERIALS AND METHODS Reactive hyperemia (RH), which was induced using a device designed for remote and transient occlusion of the aorta and vena cava, was measured by blood-oxygen-level-dependent MRI. Twenty-eight days after femoral artery ligation, peak height (PH) and time to peak (TTP) of the RH response was compared with sham-operated animals in 10-week-old C57Bl6, 9-month-old C57Bl6, and 9-month-old Ldlr(-/-)Apobec(-/-) mice. The contribution of VEGF to functional recovery was assessed in young mice. Angiogenesis was quantified using an anti-PECAM1 radioimmunoassay. RESULTS In young animals, angiogenesis was maximal 7 days after ligation, whereas functional recovery took 28 days. Inhibition of VEGF eliminated the angiogenesis seen at 7 days and reduced RH (PH, P < 0.05). At day 28, RH was altered in old (TTP, P < 0.05) and atherosclerotic (PH, P < 0.05; TTP, P < 0.05) animals. RH was different in young, old, and atherosclerotic sham animals. Old and atherosclerotic mice showed reduced angiogenesis. CONCLUSION The method presented herein can provide a sensitive assay for the functional assessment of arteriogenesis and highlights the contribution of VEGF, age, and atherosclerosis to this process.
Collapse
Affiliation(s)
- Joan M Greve
- Department of Biomedical Imaging, Genentech, Inc., South San Franscisco, California 94080, USA.
| | | | | | | | | | | | | |
Collapse
|
28
|
Wu WC, Wang J, Detre JA, Ratcliffe SJ, Floyd TF. Transit delay and flow quantification in muscle with continuous arterial spin labeling perfusion-MRI. J Magn Reson Imaging 2008; 28:445-52. [PMID: 18666182 DOI: 10.1002/jmri.21322] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Abstract
PURPOSE To test the hypothesis that flow measurements using continuous arterial spin labeling (CASL) magnetic resonance imaging (MRI) in muscle depend upon transit delay, and examine the repeatability of CASL measurements. MATERIALS AND METHODS A total of 23 healthy subjects underwent CASL imaging of the calf, foot, and forearm with varying postlabeling delay (PLD = 1000, 1500, and 1900 msec). Experiments were conducted on a 3.0T system. An orthopedic tourniquet system was employed to create a five-minute period of ischemia followed by a transient hyperemic flow. Imaging commenced two minutes prior to cuff inflation and ended three minutes after cuff release. RESULTS CASL was found able to well resolve the time course of the hyperemic flow pattern with an effective TR of 16 seconds, although we were unable to establish that a plateau had been reached in the flow measurements even at a PLD as long as 1900 msec. Peak hyperemic flow measurements compared favorably with those obtained with contrast-enhanced (CE) MRI following a similar period of ischemia. Region-of-interest (ROI)-based repeated measurements varied by approximately 20% over a period of one hour. CONCLUSION In all anatomic regions studied, flow measurements were found to increase with PLD, suggesting the prolonged transit delay in muscle.
Collapse
Affiliation(s)
- Wen-Chau Wu
- Department of Radiology, Hospital of University of Pennsylvania, Philadelphia, Pennsylvania, USA
| | | | | | | | | |
Collapse
|
29
|
Huegli RW, Schulte AC, Aschwanden M, Thalhammer C, Kos S, Jacob AL, Bilecen D. Effects of percutaneous transluminal angioplasty on muscle BOLD-MRI in patients with peripheral arterial occlusive disease: preliminary results. Eur Radiol 2008; 19:509-15. [DOI: 10.1007/s00330-008-1168-6] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2007] [Accepted: 08/07/2008] [Indexed: 11/24/2022]
|
30
|
Schulte AC, Aschwanden M, Bilecen D. Calf muscles at blood oxygen level-dependent MR imaging: aging effects at postocclusive reactive hyperemia. Radiology 2008; 247:482-9. [PMID: 18372453 DOI: 10.1148/radiol.2472070828] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively investigate age-related changes in muscle reperfusion by using blood oxygen level-dependent (BOLD) magnetic resonance (MR) imaging of the calf in young and elderly healthy volunteers during postocclusive reactive hyperemia. MATERIALS AND METHODS Institutional review board approval and informed consent were obtained. Eleven healthy elderly (mean age, 64.0 years +/- 6.4 [standard deviation]; six men, five women) and 17 healthy young volunteers (mean age, 30.3 years +/- 6.5; seven men, 10 women) underwent muscle BOLD MR imaging of the calf. A fat-suppressed T2*-weighted single-shot multiecho echo-planar imaging sequence was used. Temporary vascular occlusion was induced with suprasystolic cuff compression of the thigh. T2* time courses of the muscle BOLD MR signal intensity were obtained from four calf muscles and were characterized by the following curve parameters: hyperemia peak value, time to peak, and T2* end value after 360 seconds of hyperemia. Differences in these parameters between the two cohorts were assessed by using a Student t test. RESULTS Considerably lower T2* maxima were observed in the elderly group during hyperemia (P < .005), with a mean hyperemia peak value of 13.1% +/- 3.0 compared with 18.9% +/- 4.8 in young healthy adults. Peaking occurred earlier in the elderly group (P < .05), with a mean time to peak of 32.2 seconds +/- 10.6 compared with 43.1 seconds +/- 10.7 in young adults. Furthermore, the elderly group had a significantly slower decrease of the muscle BOLD signal after the hyperemia peak (P < .001), which led to a higher end value of 8.6% +/- 3.0 compared with 2.6% +/- 2.1 in the young group. CONCLUSION BOLD MR imaging results of the calf demonstrated statistically significant age-dependent differences in the rate, intensity, and recovery of the postocclusive muscle BOLD signal.
Collapse
|
31
|
Wu WC, Wang J, Detre JA, Wehrli FW, Mohler E, Ratcliffe SJ, Floyd TF. Hyperemic flow heterogeneity within the calf, foot, and forearm measured with continuous arterial spin labeling MRI. Am J Physiol Heart Circ Physiol 2008; 294:H2129-36. [PMID: 18310508 DOI: 10.1152/ajpheart.01399.2007] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Arterial spin labeling (ASL) is a noninvasive magnetic resonance imaging (MRI) technique for microvascular blood flow measurement. We used a continuous ASL scheme (CASL) to investigate the hyperemic flow difference between major muscle groups in human extremities. Twenty-four healthy subjects with no evidence of vascular disease were recruited. MRI was conducted on a 3.0 Tesla Siemens Trio whole body system with a transmit/receive knee coil. A nonmagnetic orthopedic tourniquet system was used to create a 5-min period of ischemia followed by a period of hyperemic flow (occlusion pressure = 250 mmHg). CASL imaging, lasting from 2 min before cuff inflation to 3 min after cuff deflation, was performed on the midcalf, midfoot, and midforearm in separate sessions from which blood flow was quantified with an effective temporal resolution of 16 s. When muscles in the same anatomic location were compared, hyperemic flow was found to be significantly higher in the compartments containing muscles known to have relatively higher slow-twitch type I fiber compositions, such as the soleus muscle in the calf and the extensors in the forearm. In the foot, the plantar flexors exhibited a slightly delayed hyperemic response relative to that of the dorsal compartment, but no between-group flow difference was observed. These results demonstrate that CASL is sensitive to flow heterogeneity between diverse muscle groups and that nonuniform hyperemic flow patterns following an ischemic paradigm correlate with relative fiber-type predominance.
Collapse
Affiliation(s)
- Wen-Chau Wu
- Department of Radiology, The Hospital of University of Pennsylvania, 3400 Spruce St., Philadelphia, PA 19104, USA
| | | | | | | | | | | | | |
Collapse
|
32
|
Hsu LY, Wragg A, Anderson SA, Balaban RS, Boehm M, Arai AE. Automatic assessment of dynamic contrast-enhanced MRI in an ischemic rat hindlimb model: an exploratory study of transplanted multipotent progenitor cells. NMR IN BIOMEDICINE 2008; 21:111-9. [PMID: 17506036 DOI: 10.1002/nbm.1166] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
This study presents computerized automatic image analysis for quantitatively evaluating dynamic contrast-enhanced MRI in an ischemic rat hindlimb model. MRI at 7 T was performed on animals in a blinded placebo-controlled experiment comparing multipotent adult progenitor cell-derived progenitor cell (MDPC)-treated, phosphate buffered saline (PBS)-injected, and sham-operated rats. Ischemic and non-ischemic limb regions of interest were automatically segmented from time-series images for detecting changes in perfusion and late enhancement. In correlation analysis of the time-signal intensity histograms, the MDPC-treated limbs correlated well with their corresponding non-ischemic limbs. However, the correlation coefficient of the PBS control group was significantly lower than that of the MDPC-treated and sham-operated groups. In semi-quantitative parametric maps of contrast enhancement, there was no significant difference in hypo-enhanced area between the MDPC and PBS groups at early perfusion-dependent time frames. However, the late-enhancement area was significantly larger in the PBS than the MDPC group. The results of this exploratory study show that MDPC-treated rats could be objectively distinguished from PBS controls. The differences were primarily determined by late contrast enhancement of PBS-treated limbs. These computerized methods appear promising for assessing perfusion and late enhancement in dynamic contrast-enhanced MRI.
Collapse
Affiliation(s)
- Li-Yueh Hsu
- National Heart Lung and Blood Institute, National Institutes of Health, Department of Health and Human Services, Bethesda, MD 20892-1061, USA
| | | | | | | | | | | |
Collapse
|
33
|
Klarhöfer M, Madörin P, Bilecen D, Scheffler K. Assessment of muscle oxygenation with balanced SSFP: A quantitative signal analysis. J Magn Reson Imaging 2008; 27:1169-74. [DOI: 10.1002/jmri.21334] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
|
34
|
Lowe AS, Barker GJ, Beech JS, Ireland MD, Williams SCR. A method for removing global effects in small-animal functional MRI. NMR IN BIOMEDICINE 2008; 21:53-8. [PMID: 17436355 DOI: 10.1002/nbm.1165] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Global effects in functional MRI are temporal modulations in signal intensity resulting from various scanner and subject phenomena. These effects contribute to the overall variance, reducing the effect size associated with an experimental paradigm. Statistical estimations that include an approximation for concurrent global effects will reduce the residual error within the model and so improve statistical power of the study. Conventionally, estimates of global effects are derived from mean intracerebral signal intensities, but these may be prone to contributions from localised experimentally evoked signal changes. In such cases, inaccurate estimates of global effects may result in erroneous inferences of neural modulations based on statistical artefact. A novel, computationally simple, method of estimating global effects is proposed using muscle tissue acquired within the same acquisition volume. Quantitative improvements in sensitivity are reported for a somatosensory stimulation paradigm using global muscle signal intensities as a covariate of no-interest. The method is independent of local neurogenic signal changes and, under particular experimental conditions, may be more representative of true global effects. The utility of this strategy to applications in small-animal functional MRI that evoke systemic physiological changes as a result of the experimental manipulation is critically discussed.
Collapse
Affiliation(s)
- Andrew S Lowe
- Experimental Neuroimaging Group, Department of Physiology, Anatomy and Genetics, University of Oxford, Oxford, UK.
| | | | | | | | | |
Collapse
|
35
|
Abstract
INTRODUCTION Peripheral arterial disease (PAD) is characterized by lower limb arterial obstruction due to atherosclerosis and is increasingly common. Presently used methods for diagnosis and follow-up as well as for assessment of novel therapies are limited. MATERIALS AND METHODS Three distinct magnetic resonance examinations were developed. The first was high-resolution black-blood atherosclerotic plaque imaging of the superficial femoral artery using a surface coil and flow saturation. Second, first-pass contrast-enhanced dual-contrast perfusion imaging of the calf muscle was performed at peak exercise using a magnetic resonance (MR)-compatible pedal ergometer. Lastly, (31)P MR spectroscopy was also performed at peak exercise to measure phosphocreatine (PCr) recovery kinetics. RESULTS Seventeen patients (age, 63 +/- 10 yrs) with mild to moderate PAD were studied with black-blood atherosclerotic plaque imaging. Mean atherosclerotic plaque volume measured was 7.27 +/- 3.73 cm(3). Eleven patients (age, 61 +/- 11 yrs) with mild to moderate symptomatic PAD and 22 normal control subjects were studied with first-pass contrast-enhanced perfusion imaging. Perfusion index was stepwise increased from patients to normal subjects with matched workload to normal subjects at maximal exercise. For PCr recovery kinetics, 20 patients with mild to moderate PAD and 14 controls were studied. The median recovery time constant of PCr was 34.7 seconds in the controls and 91.0 seconds in the PAD patients (P < 0.0001). CONCLUSIONS Three distinct MR examinations of different aspects of peripheral arterial disease have been developed and tested and shown to differentiate patients with mild to moderate PAD from normal controls. Taken together, these tests are potential quantitative end points for clinical trials of novel therapies in PAD.
Collapse
Affiliation(s)
- Christopher M Kramer
- Department of Radiology, University of Virginia Health System, Charlottesville, VA 22908, USA.
| |
Collapse
|
36
|
Abstract
Oxygen plays a major role as a substrate in metabolic processes in numerous signaling pathways, in redox metabolism, and in free radical metabolism. To study the role of oxygen in normal and pathophysiological states, methods that can be used noninvasively are required. This review examines the potential of nuclear magnetic resonance techniques to study tissue oxygenation. It is written from a systems perspective, looking at detection methods with respect to the path that oxygen takes in the mammalian system-from the lungs, through the vascular system, into the interstitial space, and finally into the cell. Methods discussed range from those that are quantifiable, such as the assessment of spin lattice relaxation time in fluorocarbon solutions, to those that are more correlative, such as assessment of lactate and high energy phosphates. Since the methods vary in their site of application, sensitivity, and specificity to the quantification of oxygen, this review provides examples of how each method has been applied. This may facilitate the reader's understanding of how to optimally apply different methods to study specific biomedical problems.
Collapse
Affiliation(s)
- J F Dunn
- Department of Radiology, Physiology, and Biophysics, University of Calgary, Faculty of Medicine, Calgary, Alberta, Canada.
| |
Collapse
|
37
|
Isbell DC, Epstein FH, Zhong X, DiMaria JM, Berr SS, Meyer CH, Rogers WJ, Harthun NL, Hagspiel KD, Weltman A, Kramer CM. Calf muscle perfusion at peak exercise in peripheral arterial disease: measurement by first-pass contrast-enhanced magnetic resonance imaging. J Magn Reson Imaging 2007; 25:1013-20. [PMID: 17410566 PMCID: PMC2930771 DOI: 10.1002/jmri.20899] [Citation(s) in RCA: 71] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022] Open
Abstract
PURPOSE To develop a contrast-enhanced magnetic resonance (MR) technique to measure skeletal muscle perfusion in peripheral arterial disease (PAD). MATERIALS AND METHODS A total of 11 patients (age = 61 +/- 11 years) with mild to moderate symptomatic PAD (ankle-brachial index [ABI] = 0.75 +/- 0.08) and 22 normals were studied using an MR-compatible ergometer. PAD and normal(max) (Nl(max); N = 11) exercised to exhaustion. Nl(low) (N = 11) exercised to the same workload achieved by PAD. At peak exercise, 0.1 mm/kg of gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA) was infused at 3-4 cm(3)/second followed by a saline flush at the same rate. A dual-contrast gradient echo (GRE) sequence enabled simultaneous acquisition of muscle perfusion and arterial input function (AIF). The perfusion index (PI) was defined as the slope of the time-intensity curve (TIC) in muscle divided by the arterial TIC slope. RESULTS Median workload was 120 Joules in PAD, 210 Joules in Nl(low), and 698 Joules in Nl(max) (P < 0.001 vs. Nl(low) and PAD). Median PI was 0.29 in PAD (25th and 75th percentiles [%] = 0.20, 0.40), 0.48 in Nl(low) (25th, 75th % = 0.36, 0.62; P < 0.02 vs. PAD), and 0.69 in Nl(max) (25th, 75th % = 0.5, 0.77; P < 0.001 vs. PAD). Area under the ROC-curve for PI differentiating patients from Nl(max) was 0.95 (95% confidence interval [CI] = 0.77-0.99). CONCLUSION Peak-exercise measurement of lower limb perfusion with dual-contrast, first-pass MR distinguishes PAD from normals. This method may be useful in the study of novel therapies for PAD.
Collapse
Affiliation(s)
- David C. Isbell
- Department of Medicine, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
| | - Frederick H. Epstein
- Department of Radiology, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
- Department of Biomedical Engineering, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
| | | | - Joseph M. DiMaria
- Department of Radiology, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
| | - Stuart S. Berr
- Department of Radiology, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
- Department of Biomedical Engineering, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
| | - Craig H. Meyer
- Department of Biomedical Engineering, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
| | - Walter J. Rogers
- Department of Medicine, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
- Department of Radiology, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
| | - Nancy L. Harthun
- Department of Surgery, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
| | - Klaus D. Hagspiel
- Department of Radiology, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
| | - Arthur Weltman
- Department of Medicine, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
| | - Christopher M. Kramer
- Department of Medicine, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
- Department of Radiology, University of Virginia Health System, University of Virginia, Charlottesville, Virginia, USA
- Address reprint requests to: C.M.K., MD, University of Virginia Health System, Departments of Medicine and Radiology, Lee Street, Box 800170, Charlottesville, VA 22908.
| |
Collapse
|
38
|
Weber MA, Krix M, Delorme S. Quantitative evaluation of muscle perfusion with CEUS and with MR. Eur Radiol 2007; 17:2663-74. [PMID: 17453217 DOI: 10.1007/s00330-007-0641-y] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2006] [Revised: 02/20/2007] [Accepted: 03/22/2007] [Indexed: 11/30/2022]
Abstract
Functional imaging might increase the role of imaging in muscular diseases, since alterations of muscle morphology alone are not specific for a particular disease. Perfusion, i.e., the blood flow per tissue and time unit including capillary flow, is an important functional parameter. Pathological changes of skeletal muscle perfusion can be found in various clinical conditions, such as degenerative or inflammatory myopathies or peripheral arterial occlusive disease. This article reviews the theoretical basics of functional radiological techniques for assessing skeletal muscle perfusion and focuses on contrast-enhanced ultrasound (CEUS) and magnetic resonance imaging (MRI) techniques. Also, the applications of microvascular imaging, such as in detection of myositis and for discriminating myositis from other myopathies or evaluating peripheral arterial occlusive disease, are presented, and possible clinical indications are discussed. In conclusion, dedicated MR and CEUS methods are now available that visualize and quantify (patho-)physiologic information about microcirculation within skeletal muscles in vivo and hence establish a useful diagnostic tool for muscular diseases.
Collapse
Affiliation(s)
- Marc-André Weber
- Department of Radiology, German Cancer Research Centre, Im Neuenheimer Feld 280, 69120, Heidelberg, Germany.
| | | | | |
Collapse
|
39
|
Abstract
Magnetic resonance spectroscopy (MRS) of skeletal muscle has been successfully applied by physiologists over several decades, particularly for studies of high-energy phosphates (by (31)P-MRS) and glycogen (by (13)C-MRS). Unfortunately, the observation of these heteronuclei requires equipment that is typically not available on clinical MR scanners, such as broadband capability and a second channel for decoupling and nuclear Overhauser enhancement (NOE). On the other hand, (1)H-MR spectra of skeletal muscle can be acquired on many routine MR systems and also provide a wealth of physiological information. In particular, studies of intramyocellular lipids (IMCL) attract physiologists and endocrinologists because IMCL levels are related to insulin resistance and thus can lead to a better understanding of major health problems in industrial countries. The combination of (1)H-, (13)C-, and (31)P-MRS gives access to the major long- and short-term energy sources of skeletal muscle. This review summarizes the technical aspects and unique MR-methodological features of the different nuclei. It reviews clinical studies that employed MRS of one or more nuclei, or combinations of MRS with other MR modalities. It also illustrates that MR spectra contain additional physiological information that is not yet used in routine clinical applications.
Collapse
Affiliation(s)
- Chris Boesch
- Department of Clinical Research, MR-Spectroscopy and Methodology, University of Bern, Bern, Switzerland.
| |
Collapse
|
40
|
Stekelenburg A, Strijkers GJ, Parusel H, Bader DL, Nicolay K, Oomens CW. Role of ischemia and deformation in the onset of compression-induced deep tissue injury: MRI-based studies in a rat model. J Appl Physiol (1985) 2007; 102:2002-11. [PMID: 17255369 DOI: 10.1152/japplphysiol.01115.2006] [Citation(s) in RCA: 129] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
A rat model was used to distinguish between the different factors that contribute to muscle tissue damage related to deep pressure ulcers that develop after compressive loading. The separate and combined effects of ischemia and deformation were studied. Loading was applied to the hindlimb of rats for 2 h. Muscle tissue was examined using MR imaging (MRI) and histology. An MR-compatible loading device allowed simultaneous loading and measurement of tissue status. Two separate loading protocols incorporated uniaxial loading, resulting in tissue compression and ischemic loading. Uniaxial loading was applied to the tibialis anterior by means of an indenter, and ischemic loading was accomplished with an inflatable tourniquet. Deformation of the muscle tissue during uniaxial loading was measured using MR tagging. Compression of the tissues for 2 h led to increased T2 values, which were correlated to necrotic regions in the tibialis anterior. Perfusion measurements, by means of contrast-enhanced MRI, indicated a large ischemic region during indentation. Pure ischemic loading for 2 h led to reversible tissue changes. From the MR-tagging experiments, local strain fields were calculated. A 4.5-mm deformation, corresponding to a surface pressure of 150 kPa, resulted in maximum shear strain up to 1.0. There was a good correlation between the location of damage and the location of high shear strain. It was concluded that the large deformations, in conjunction with ischemia, provided the main trigger for irreversible muscle damage.
Collapse
Affiliation(s)
- Anke Stekelenburg
- Dept. of Biomedical Engineering, Eindhoven University of Technology, Den Dolech 2, 5600 MB Eindhoven, The Netherlands.
| | | | | | | | | | | |
Collapse
|
41
|
Ledermann HP, Heidecker HG, Schulte AC, Thalhammer C, Aschwanden M, Jaeger KA, Scheffler K, Bilecen D. Calf Muscles Imaged at BOLD MR: Correlation with TcPo2and Flowmetry Measurements during Ischemia and Reactive Hyperemia—Initial Experience. Radiology 2006; 241:477-84. [PMID: 16982813 DOI: 10.1148/radiol.2412050701] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively compare the blood oxygen level-dependent (BOLD) magnetic resonance (MR) signal intensity of calf muscle during ischemia and reactive hyperemia with laser Doppler flowmetry (LDF) and transcutaneous oxygen pressure (TcPo2) measurements, two parameters routinely used to evaluate peripheral arterial occlusive disease. MATERIALS AND METHODS The study was institutional review board approved; all volunteers gave informed consent. Fifteen healthy volunteers (eight male, seven female; mean age, 33.0 years +/- 6.1 [standard deviation]) underwent LDF, TcPo2 measurement, and BOLD MR imaging of the calf during ischemia and reactive hyperemia. The BOLD signal intensity of the gastrocnemius muscle was measured at 1.5-T single-shot multiecho gradient-echo echo-planar imaging. Time to half ischemia minimum (THIM), time to half hyperemia peak (THHP), and time to peak (TTP) after cuff deflation were measured with each method. Correlation coefficients (CCs) for associations of BOLD response with LDF and TcPo2 time courses were calculated. Student t testing of key BOLD MR, LDF, and TcPo2 measurement parameters was performed. RESULTS During ischemia, normalized LDF and TcPo2 measurements decreased similarly to BOLD MR signal intensity (CCs: 0.86 and 0.96 for associations with LDF and TcPo2 measurements, respectively). Mean THIM values were 136.0, 82.5, and 121.3 seconds for BOLD MR, LDF (P < .01), and TcPo2 (P > .05) measurements, respectively. During early reactive hyperemia, LDF and TcPo2 measurements increased rapidly to peak values, similarly to BOLD MR signal intensity (CCs: 0.81 and 0.78, respectively). Mean THHP values were 26.0, 12.5, and 44.0 seconds for BOLD MR, LDF (P < .01), and TcPo2 (P < .01) measurements, respectively. Mean TTP values were 48.7, 47.5, and 98.0 seconds for BOLD MR, LDF (P > .05), and TcPo2 (P < .01) measurements, respectively. CONCLUSION BOLD MR imaging of calf muscles-depending on underlying key parameters-has moderate to good correlation with LDF and TcPo2 measurements during ischemia and reactive hyperemia.
Collapse
Affiliation(s)
- Hans Peter Ledermann
- 1 Departments of Radiology and Angiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
42
|
Ledermann HP, Schulte AC, Heidecker HG, Aschwanden M, Jäger KA, Scheffler K, Steinbrich W, Bilecen D. Blood Oxygenation Level–Dependent Magnetic Resonance Imaging of the Skeletal Muscle in Patients With Peripheral Arterial Occlusive Disease. Circulation 2006; 113:2929-35. [PMID: 16785340 DOI: 10.1161/circulationaha.105.605717] [Citation(s) in RCA: 120] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Background—
Blood oxygenation level–dependent (BOLD) magnetic resonance imaging (MRI) has been used to measure T2* changes in skeletal muscle tissue of healthy volunteers. The BOLD effect is assumed to primarily reflect changes in blood oxygenation at the tissue level. We compared the calf muscle BOLD response of patients with peripheral arterial occlusive disease (PAOD) to that of an age-matched non-PAOD group during postischemic reactive hyperemia.
Methods and Results—
PAOD patients (n=17) with symptoms of intermittent calf claudication and an age-matched non-PAOD group (n=11) underwent T2*-weighted single-shot multiecho planar imaging on a whole-body magnetic resonance scanner at 1.5 T. Muscle BOLD MRI of the calf was performed during reactive hyperemia provoked by a cuff-compression paradigm. T2* maps were generated with an automated fitting procedure. Maximal T2* change (ΔT2*
max
) and time to peak to reach ΔT2*
max
for gastrocnemius, soleus, tibial anterior, and peroneal muscle were evaluated. Compared with the non-PAOD group, patients revealed significantly lower ΔT2*
max
-values, with a mean of 7.3±5.3% versus 13.1±5.6% (
P
<0.001), and significantly delayed time-to-peak values, with a mean of 109.3±79.3 versus 32.2±13.3 seconds (
P
<0.001).
Conclusions—
T2* time courses of the muscle BOLD MRI signal during postocclusive reactive hyperemia revealed statistically significant differences in the key parameters (ΔT2*
max
; time to peak) in PAOD patients compared with age-matched non-PAOD controls.
Collapse
Affiliation(s)
- Hans-Peter Ledermann
- Department of Radiology, University Hospital Basel, Petersgraben 4, 4031 Basel, Switzerland
| | | | | | | | | | | | | | | |
Collapse
|
43
|
Pohmann R, Künnecke B, Fingerle J, von Kienlin M. Fast perfusion measurements in rat skeletal muscle at rest and during exercise with single-voxel FAIR (flow-sensitive alternating inversion recovery). Magn Reson Med 2006; 55:108-15. [PMID: 16315203 DOI: 10.1002/mrm.20737] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Non-invasive measurement of perfusion in skeletal muscle by in vivo magnetic resonance remains a challenge due to its low level and the correspondingly low signal-to-noise ratio. To enable accurate, quantitative, and time-resolved perfusion measurements in the leg muscle, a technique with a high sensitivity is required. By combining a flow-sensitive alternating inversion recovery (FAIR)-sequence with a single-voxel readout, we have developed a new technique to measure the perfusion in the rat gastrocnemius muscle at rest, yielding an average value of 19.4 +/- 4.8 mL/100 g/min (n = 22). In additional experiments, perfusion changes were elicited by acute ischemia and reperfusion or by exercise induced by electrical, noninvasive muscle stimulation with varying duration and intensity. The perfusion time courses during these manipulations were measured with a temporal resolution of 2.2 min, showing increases in perfusion of a factor of up to 2.5. In a direct comparison, the results agreed closely with values found with microsphere measurements in the same animals. The quantitative and noninvasive method can significantly facilitate the investigation of atherosclerotic diseases and the examination of drug efficacy.
Collapse
Affiliation(s)
- Rolf Pohmann
- F. Hoffmann-La Roche Ltd, CH-4070 Basel, Switzerland.
| | | | | | | |
Collapse
|
44
|
Thompson RB, Aviles RJ, Faranesh AZ, Raman VK, Wright V, Balaban RS, McVeigh ER, Lederman RJ. Measurement of skeletal muscle perfusion during postischemic reactive hyperemia using contrast-enhanced MRI with a step-input function. Magn Reson Med 2005; 54:289-98. [PMID: 16032661 PMCID: PMC1356658 DOI: 10.1002/mrm.20535] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
The regional distribution of skeletal muscle blood flow was measured during postischemic reactive hyperemia using Gd-DTPA contrast-enhanced (CE) MRI. The release of an occlusive thigh cuff was used to deliver a step-input of contrast concentration that was coincident with the onset of reactive hyperemia. A first-order tracer kinetic equation was used to estimate the unidirectional influx constant, Ki (ml/100 g/min), and the distribution volume of Gd-DTPA in the tissue, v(e), from T1-weighted images acquired with saturation recovery (SR) steady-state free precession (SSFP) and spoiled gradient-echo (SPGR) protocols. The capillary permeability surface (PS) area increased significantly during reactive hyperemia, which facilitated rapid extraction of Gd-DTPA during the first pass. Regional muscle group studies from 11 normal volunteers yielded blood flow (Ki) values of 108.3 +/- 34.1 ml/100 g/min in the gastrocnemius, 184.3 +/- 41.3 ml/100 g/min in the soleus, and 122.4 +/- 34.4 ml/100 g/min in the tibialis anterior. The distribution volumes (v(e)) in the corresponding muscle groups were respectively 8.3% +/- 2.1%, 9.3% +/- 1.9%, and 7.9% +/- 1.8% from the kinetic model, and 8.8% +/- 2.4%, 9.1% +/- 1.9%, and 7.2% +/- 1.4% from tissue relaxometry studies. Bulk blood flow studies in the same volunteers using phase-contrast velocimetry (popliteal artery) yielded significantly lower flow values, but with a correlation coefficient R2 = 0.62 and P = 0.004.
Collapse
Affiliation(s)
- Richard B Thompson
- Laboratory of Cardiac Energetics, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA.
| | | | | | | | | | | | | | | |
Collapse
|
45
|
Lutz AM, Weishaupt D, Amann-Vesti BR, Pfammatter T, Goepfert K, Marincek B, Nanz D. Assessment of skeletal muscle perfusion by contrast medium first-pass magnetic resonance imaging: technical feasibility and preliminary experience in healthy volunteers. J Magn Reson Imaging 2004; 20:111-21. [PMID: 15221816 DOI: 10.1002/jmri.20092] [Citation(s) in RCA: 29] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
PURPOSE To probe the potential and pitfalls of contrast medium first-pass skeletal muscle perfusion imaging under reproducible stress conditions. MATERIALS AND METHODS Magnetic resonance (MR) signal dynamics in calf muscle and lower-leg arteries of 20 healthy volunteers were analyzed under postarterial occlusion reactive hyperemia and concurrent contrast medium first pass, using a saturation recovery spoiled gradient-echo type sequence without heartbeat synchronization. The signal vs. time curves were analyzed descriptively and by two-compartment deconvolution analysis. RESULTS Highly significant changes in calf muscle signal dynamics in the hyperemic leg vs. those in the contralateral leg at rest were found in phenomenological and deconvolution analysis. Although a distortion of the arterial signal derived input function by inflow effects was found to cause large variations of the deconvolution results, the magnitude of the observed effects suggested a potential for immediate visual detection of areas with reduced tissue perfusion. CONCLUSION The first-pass approach appeared promising for visual evaluation. However, a disentanglement of inflow and contrast medium-induced effects on arterial signal intensity was deemed a prerequisite for input function-based numerical assessment.
Collapse
Affiliation(s)
- Amelie M Lutz
- Institute of Diagnostic Radiology, University Hospital Zurich, Zurich, Switzerland
| | | | | | | | | | | | | |
Collapse
|
46
|
Shoaib M, Lowe AS, Williams SCR. Imaging localised dynamic changes in the nucleus accumbens following nicotine withdrawal in rats. Neuroimage 2004; 22:847-54. [PMID: 15193614 DOI: 10.1016/j.neuroimage.2004.01.026] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2003] [Revised: 01/16/2004] [Accepted: 01/20/2004] [Indexed: 11/20/2022] Open
Abstract
This study utilises pharmacological functional magnetic resonance imaging (fMRI) to examine the neurobiological mechanisms through which nicotine produces dependence. Using an established regime to induce physical dependence to nicotine in rats (osmotic minipumps delivering 3.16 mg/kg/day nicotine for 7 days SC), animals were subsequently anaesthetised under urethane and positioned in a stereotaxic frame to allow collection of gradient echo whole brain images with a 4.7-T MRI spectrometer. Rats were initially scanned for 34 min (40 baseline image volumes, 1 volume per 51 s) then challenged with mecamylamine (1.0 mg/kg SC) or saline (1 ml/kg) and scanned for a further 68 min (80 image volumes). Mecamylamine precipitated highly significant positive changes in fMRI blood oxygen level dependent (BOLD) contrast that were predominantly localised to the NAc of nicotine-dependent rats. Saline-treated rats challenged with the same dose of mecamylamine exhibited similar but smaller increases in BOLD contrast although such changes were less defined around the NAc. Precipitated withdrawal also elicited statistically significant negative BOLD contrast changes in widespread cortical regions. These findings are consistent with previous neurochemical reports on decreases in dopamine in the NAc during nicotine withdrawal. This fMRI study further highlights the potential and power to image the neurobiological events during nicotine dependence.
Collapse
Affiliation(s)
- Mohammed Shoaib
- Section of Behavioural Pharmacology, Division of Psychological Medicine, Institute of Psychiatry, Kings College London, London SE5 8AF, UK.
| | | | | |
Collapse
|
47
|
Baudelet C, Ansiaux R, Jordan BF, Havaux X, Macq B, Gallez B. Physiological noise in murine solid tumours using T2*-weighted gradient-echo imaging: a marker of tumour acute hypoxia? Phys Med Biol 2004; 49:3389-411. [PMID: 15379021 DOI: 10.1088/0031-9155/49/15/006] [Citation(s) in RCA: 95] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
T2*-weighted gradient-echo magnetic resonance imaging (T2*-weighted GRE MRI) was used to investigate spontaneous fluctuations in tumour vasculature non-invasively. FSa fibrosarcomas, implanted intramuscularly (i.m.) in the legs of mice, were imaged at 4.7 T, over a 30 min or 1 h sampling period. On a voxel-by-voxel basis, time courses of signal intensity were analysed using a power spectrum density (PSD) analysis to isolate voxels for which signal changes did not originate from Gaussian white noise or linear drift. Under baseline conditions, the tumours exhibited spontaneous signal fluctuations showing spatial and temporal heterogeneity over the tumour. Statistically significant fluctuations occurred at frequencies ranging from 1 cycle/3 min to 1 cycle/h. The fluctuations were independent of the scanner instabilities. Two categories of signal fluctuations were reported: (i) true fluctuations (TFV), i.e., sequential signal increase and decrease, and (ii) profound drop in signal intensity with no apparent signal recovery (SDV). No temporal correlation between tumour and contralateral muscle fluctuations was observed. Furthermore, treatments aimed at decreasing perfusion-limited hypoxia, such as carbogen combined with nicotinamide and flunarizine, decreased the incidence of tumour T2*-weighted GRE fluctuations. We also tracked dynamic changes in T2* using multiple GRE imaging. Fluctuations of T2* were observed; however, fluctuation maps using PSD analysis could not be generated reliably. An echo-time dependency of the signal fluctuations was observed, which is typical to physiological noise. Finally, at the end of T2*-weighted GRE MRI acquisition, a dynamic contrast-enhanced MRI was performed to characterize the microenvironment in which tumour signal fluctuations occurred in terms of vessel functionality, vascularity and microvascular permeability. Our data showed that TFV were predominantly located in regions with functional vessels, whereas SDV occurred in regions with no contrast enhancement as the result of vessel functional impairment. Furthermore, transient fluctuations appeared to occur preferentially in neoangiogenic hyperpermeable vessels. The present study suggests that spontaneous T2*-weighted GRE fluctuations are very likely to be related to the spontaneous fluctuations in blood flow and oxygenation associated with the pathophysiology of acute hypoxia in tumours. The disadvantage of the T2*-weighted GRE MRI technique is the complexity of signal interpretation with regard to pO2 changes. Compared to established techniques such as intravital microscopy or histological assessments, the major advantage of the MRI technique lies in its capacity to provide simultaneously both temporal and detailed spatial information on spontaneous fluctuations throughout the tumour.
Collapse
Affiliation(s)
- Christine Baudelet
- Laboratory of Biomedical Magnetic Resonance, Université Catholique de Louvain, Brussels, Belgium
| | | | | | | | | | | |
Collapse
|
48
|
Reijnders K, English SJ, Krishna MC, Cook JA, Sowers AL, Mitchell JB, Zhang Y. Influence of body temperature on the BOLD effect in murine SCC tumors. Magn Reson Med 2004; 51:389-93. [PMID: 14755665 DOI: 10.1002/mrm.10695] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Changes in the blood oxygen level dependent (BOLD) enhancements in tumors (squamous cell carcinoma, (SCCVII)) implanted in mice maintained at core temperatures of 30 degrees C or 37 degrees C were measured using MRI and compared to tumor oxygen levels obtained using an oxygen-sensitive Eppendorf electrode. Tumors were implanted in a hindleg of the mice intramuscularly. Tumor-bearing mice were imaged by BOLD MRI, while first breathing air and then carbogen (95% O2, 5% CO2) for 15-min intervals at a core temperature of 30 degrees C. After an equilibration period, the identical regimen was conducted with the same animal maintained at 37 degrees C. This procedure was repeated with additional mice starting at 37 degrees C followed by imaging at 30 degrees C. Likewise, oxygen electrode measurements of the tumor were determined at core temperatures of 30 degrees C and 37 degrees C. The Eppendorf measurements showed that tumors in animals maintained at 30 degrees C were significantly more hypoxic than at 37 degrees C. MRI studies demonstrated stronger BOLD enhancement at 30 degrees C than at 37 degrees C, suggesting significant changes in hypoxia and/or blood flow in tumors at these temperatures. The findings of the study stress the importance of maintaining normal core temperature when assessing tumor oxygen status using functional imaging modalities or oxygen-sensitive electrodes.
Collapse
Affiliation(s)
- Koen Reijnders
- Radiation Biology Branch, Center for Cancer Research, National Cancer Institute, Bethesda, Maryland 20892, USA
| | | | | | | | | | | | | |
Collapse
|
49
|
Vanderthommen M, Duteil S, Wary C, Raynaud JS, Leroy-Willig A, Crielaard JM, Carlier PG. A comparison of voluntary and electrically induced contractions by interleaved 1H- and 31P-NMRS in humans. J Appl Physiol (1985) 2003; 94:1012-24. [PMID: 12571132 DOI: 10.1152/japplphysiol.00887.2001] [Citation(s) in RCA: 146] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Skeletal muscle voluntary contractions (VC) and electrical stimulations (ES) were compared in eight healthy men. High-energy phosphates and myoglobin oxygenation were simultaneously monitored in the quadriceps by interleaved (1)H- and (31)P-NMR spectroscopy. For the VC protocol, subjects performed five or six bouts of 5 min with a workload increment of 10% of maximal voluntary torque (MVT) at each step. The ES protocol consisted of a 13-min exercise with a load corresponding to 10% MVT. For both protocols, exercise consisted of 6-s isometric contractions and 6-s rest cycles. For an identical mechanical level (10% MVT), ES induced larger changes than VC in the P(i)-to-phosphocreatine ratio [1.38 +/- 1.14 (ES) vs. 0.13 +/- 0.04 (VC)], pH [6.69 +/- 0.11 (ES) vs. 7.04 +/- 0.07 (VC)] and myoglobin desaturation [43 +/- 15.9 (ES) vs. 6.1 +/- 4.6% (VC)]. ES activated the muscle facing the NMR coil to a greater extent than did VCs when evaluated under identical technical conditions. This metabolic pattern can be interpreted in terms of specific temporal and spatial muscle cell recruitment. Furthermore, at identical levels of energy charge, the muscle was more acidotic and cytoplasm appeared more oxygenated during ES than during VC. These results are in accordance with a preferential recruitment of type II fibers and a relative muscle hyperperfusion during ES.
Collapse
Affiliation(s)
- M Vanderthommen
- Physical Medicine Department, University Hospital, 4000 Liège, Belgium.
| | | | | | | | | | | | | |
Collapse
|
50
|
Baudelet C, Gallez B. How does blood oxygen level-dependent (BOLD) contrast correlate with oxygen partial pressure (pO2) inside tumors? Magn Reson Med 2002; 48:980-6. [PMID: 12465107 DOI: 10.1002/mrm.10318] [Citation(s) in RCA: 177] [Impact Index Per Article: 7.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Blood oxygen level-dependent (BOLD) contrast-based functional MRI (fMRI) has been reported as a method to assess the evolution of tumor oxygenation after hyperoxic treatments, because of its sensitivity to changes in blood flow and deoxyhemoglobin content. However a number of questions remain: 1) In view of tumor heterogeneity, how good is the correlation between the MR parameters in gradient-echo imaging (signal intensity (SI) or effective transverse relaxation time (T(*)(2))) and local tumor oxygen partial pressure (pO(2))? 2) Is the magnitude of the change in SI or T(*)(2) a quantitative marker for variation in pO(2)? 3) Is initial T(*)(2) a good marker for initial pO(2)? To address these questions, murine tumors were imaged during respiratory challenges at 4.7 Tesla, using fiber-optic microprobes to simultaneously acquire tumor pO(2) and erythrocyte flux. The BOLD signal response (SI and T(*)(2)) was temporally correlated with changes in pO(2). However, the magnitude of the signal bore no absolute relation to pO(2) across tumors, i.e., a given change in SI corresponded to a 25 mmHg pO(2) change in one tumor, but to a 100 mmHg change in another. The initial T(*)(2) value did not reliably predict tumor oxygenation at the beginning of the experiment. In conclusion, the major advantages of the technique include noninvasiveness, high spatial resolution, and real-time detection of pO(2) fluctuations. Information afforded by the BOLD imaging technique is qualitative in nature and may be combined with other techniques capable of providing an absolute measure of pO(2).
Collapse
Affiliation(s)
- Christine Baudelet
- Laboratory of Medicinal Chemistry and Radiopharmacy, Université Catholique de Louvain, Brussels, Belgium
| | | |
Collapse
|