1
|
Role of Echocardiography in the Diagnosis and Interventional Management of Atrial Septal Defects. Diagnostics (Basel) 2022; 12:diagnostics12061494. [PMID: 35741304 PMCID: PMC9222141 DOI: 10.3390/diagnostics12061494] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 06/03/2022] [Accepted: 06/13/2022] [Indexed: 11/17/2022] Open
Abstract
This review centers on the usefulness of echo-Doppler studies in the diagnosis of ostium secundum atrial septal defects (ASDs) and in their management, both in children and adults. Transthoracic echocardiography can easily identify the secundum ASDs and also differentiate secundum ASDs from other kinds of ASDs, such as ostium primum ASD, sinus venosus ASD and coronary sinus ASD, as well as patent foramen ovale. Preliminary selection of patients for device occlusion can be made by transthoracic echocardiograms while final selection is based on transesophageal (TEE) or intracardiac (ICE) echocardiographic studies with optional balloon sizing of ASDs. TEE and ICE are extremely valuable in guiding device implantation and in evaluating the position of the device following its implantation. Echo-Doppler evaluation during follow-up is also useful in documenting improvements in ventricular size and function, in assessing the device position, in detecting residual shunts, and in identifying rare device-related complications. Examples of echo images under each section are presented. The reasons why echo-Doppler is very valuable in diagnosing and managing ASDs are extensively discussed.
Collapse
|
2
|
Gore Cardioform atrial septal occluder: deployment procedure and techniques for closing challenging secundum atrial septal defects. Cardiol Young 2021; 31:1885-1892. [PMID: 34620264 DOI: 10.1017/s1047951121003966] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Ostium secundum atrial septal defects are mostly closed in the cardiac catheterisation laboratories using either Amplatzer® (Abbott Laboratories, IL) atrial septal occluder, Gore® Cardioform septal occluder and more recently using the recently approved (US FDA approval June 2019) Gore® Cardioform atrial septal defect occluder (W. L. Gore & Associates, AZ). Similar to any new device in the market, there is a learning curve to the deployment of this device. We therefore aim to report the key features about this new Gore Cardioform atrial septal defect occluder device with special emphasis on technical aspects that can be employed during transcatheter closure of challenging ostium secundum atrial septal defects using this device.
Collapse
|
3
|
Statistical Treatment of Clinical Investigations in Pediatric Cardiology. CHILDREN-BASEL 2021; 8:children8040296. [PMID: 33921399 PMCID: PMC8069261 DOI: 10.3390/children8040296] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/25/2021] [Revised: 04/09/2021] [Accepted: 04/10/2021] [Indexed: 11/17/2022]
Abstract
This paper describes various statistical methods used by the author during multiple studies conducted by the author. Initially, the data were scrutinized to ensure normal distribution, and expressed as mean ± standard deviation (SD) or standard error of mean (SEM) for normally distributed variables. Medians and ranges were given for the data with skewed distribution. Two tailed, paired t tests or independent sample t tests (analysis of variance) were used for normally distributed data, while non-parametric chi-square or similar other tests were utilized for data with skewed distribution. Statistical significance was set at a p value of < 0.05. Bonferroni correction was applied when the study involves multiple comparisons. A number of other statistical methods used during these studies were also discussed. Finally, special methods used in evaluating aortic remodeling subsequent to balloon angioplasty of native aortic coarctation were reviewed.
Collapse
|
4
|
Outcomes of Device Closure of Atrial Septal Defects. CHILDREN-BASEL 2020; 7:children7090111. [PMID: 32854325 PMCID: PMC7552712 DOI: 10.3390/children7090111] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2020] [Revised: 08/18/2020] [Accepted: 08/19/2020] [Indexed: 02/07/2023]
Abstract
Several devices have been designed and tried over the years to percutaneously close atrial septal defects (ASDs). Most of the devices were first experimented in animal models with subsequent clinical testing in human subjects. Some devices were discontinued or withdrawn from further clinical use for varied reasons and other devices received Food and Drug Administration (FDA) approval with consequent continued usage. The outcomes of both discontinued and currently used devices was presented in some detail. The results of device implantation are generally good when appropriate care and precautions are undertaken. At this time, Amplatzer Septal Occluder is most frequently utilized device for occlusion of secundum ASD around the world.
Collapse
|
5
|
Ali M, Salah El-Din H, Bakhoum S, El-Sisi A, Mahmood K, Farouk H, Kandil H. Feasibility of percutaneous closure of atrial septal defects in adults under transthoracic echocardiography guidance using the Figulla atrial septal defect occluder device. J Saudi Heart Assoc 2018; 30:21-27. [PMID: 29296061 PMCID: PMC5744024 DOI: 10.1016/j.jsha.2017.04.002] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2017] [Revised: 03/10/2017] [Accepted: 04/06/2017] [Indexed: 11/28/2022] Open
Abstract
Background Closure of atrial septal defect (ASD) among adults under transthoracic echocardiography (TTE) guidance using devices other than the Amplatzer Septal Occluder has not been extensively tested. Aim of work Assessment of the safety and efficiency of secundum ASD closure using the Occlutech Figulla ASD Occluder under TTE guidance in adult patients with hemodynamically significant secundum ASD. Methods Twenty patients (mean age, 32.9 ± 9.7, 75% of them females) were enrolled in the study. All patients underwent TTE and transoesophageal echocardiography (TEE) to assess the characteristics of the ASD prior to percutaneous closure. Procedures were performed using the Figulla Occluder device under both fluoroscopic and TTE guidance. Follow-up clinical and TTE examinations were done at 1, 3, and 6 months following the procedure. Results TTE estimated mean ASD size was 21.7 ± 7.3 mm with adequate rims except for the aortic rim (deficient in one third of cases). Mean device size was 28.1 ± 8.6 mm with mean procedure and fluoroscopic times of 46.2 ± 16.4 and 15.7 ± 5.4 minutes respectively. ASD was successfully closed in all patients. Two patients showed a small residual shunt immediately after the device placement that disappeared by the end of the 2nd followup TTE examination. Transient complications were detected in 2 patients. All patients were asymptomatic during the follow-up period. Conclusion Transcatheter closure of secundum ASD in adults under TTE guidance using the Occlutech Figulla ASD occluder device is safe and effective when performed in a tertiary center and by expert echocardiographers and interventional cardiologists.
Collapse
Affiliation(s)
- Mahmoud Ali
- Cardiology Department, Kasr Alainy Faculty of Medicine, Cairo University, Cairo, EgyptaEgypt
| | - Hesham Salah El-Din
- Cardiology Department, Kasr Alainy Faculty of Medicine, Cairo University, Cairo, EgyptaEgypt
| | - Sameh Bakhoum
- Cardiology Department, Kasr Alainy Faculty of Medicine, Cairo University, Cairo, EgyptaEgypt
| | - Amal El-Sisi
- Cardiology Department, Kasr Alainy Faculty of Medicine, Cairo University, Cairo, EgyptaEgypt
| | - Kareem Mahmood
- Cardiology Department, Kasr Alainy Faculty of Medicine, Cairo University, Cairo, EgyptaEgypt
| | - Heba Farouk
- Cardiology Department, Kasr Alainy Faculty of Medicine, Cairo University, Cairo, EgyptaEgypt
| | - Hossam Kandil
- Cardiology Department, Kasr Alainy Faculty of Medicine, Cairo University, Cairo, EgyptaEgypt
| |
Collapse
|
6
|
Syamasundar Rao P. The Journey of an Indian Pediatric Cardiologist : Dr. K. C. Chaudhuri Lifetime Achievement Award/Oration at AIIMS, New Delhi, September 2017. Indian J Pediatr 2017; 84:848-858. [PMID: 28956269 DOI: 10.1007/s12098-017-2452-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2017] [Accepted: 08/01/2017] [Indexed: 11/28/2022]
Abstract
The life journey of an Indian pediatric cardiologist, who bestowed considerable attention to the development of new knowledge and train/teach physicians around the world while providing care of patients with heart disease over a 45-y period, is reviewed. This appraisal focuses particular attention on the scientific contributions to the literature. These include spontaneous closure of physiologically advantageous ventricular septal defects, various issues related to a congenital heart defect namely, tricuspid atresia and transcatheter and, interventional pediatric cardiac procedures.
Collapse
Affiliation(s)
- P Syamasundar Rao
- Division of Pediatric Cardiology, Department of Pediatrics, University of Texas-Houston McGovern Medical School/Children's Memorial Hermann Hospital, 6410 Fannin Street, UTPB Suite # 425, Houston, TX, 77030, USA.
| |
Collapse
|
7
|
Nassif M, Abdelghani M, Bouma BJ, Straver B, Blom NA, Koch KT, Tijssen JGP, Mulder BJM, de Winter RJ. Historical developments of atrial septal defect closure devices: what we learn from the past. Expert Rev Med Devices 2016; 13:555-68. [PMID: 27112301 DOI: 10.1080/17434440.2016.1182860] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
INTRODUCTION Since King and Mills' pioneering work in percutaneous closure devices of secundum atrial septal defects (ASD) four decades ago, developments in device shape, material and implantation technique led to adoption of percutaneous ASD closure as current treatment of choice. Not only was the feasibility of such a percutaneous procedure tested altogether, but pursuing the ideal device in terms of safety and efficacy became priority. AREAS COVERED In this review we present the historical development of ASD devices in design, material and technique with clinical data, and provide the future perspectives in percutaneous ASD closures. EXPERT OPINION An 'ideal device' requires complete defect closure with negligible risk of complications using a safe, straightforward delivery technique with repositioning and retrieving properties. Some of the devices currently at hand come close to fulfilling these criteria, however none seem to provide those prerequisites completely. By understanding how challenges in device development were overcome in the past, new insights into future improvements are given.
Collapse
Affiliation(s)
- Martina Nassif
- a Department of Cardiology, Academic Medical Center , University of Amsterdam , Amsterdam , The Netherlands
| | - Mohammad Abdelghani
- a Department of Cardiology, Academic Medical Center , University of Amsterdam , Amsterdam , The Netherlands
| | - Berto J Bouma
- a Department of Cardiology, Academic Medical Center , University of Amsterdam , Amsterdam , The Netherlands
| | - Bart Straver
- b Department of Pediatric Cardiology, Academic Medical Center , University of Amsterdam , Amsterdam , The Netherlands
| | - Nico A Blom
- b Department of Pediatric Cardiology, Academic Medical Center , University of Amsterdam , Amsterdam , The Netherlands
| | - Karel T Koch
- a Department of Cardiology, Academic Medical Center , University of Amsterdam , Amsterdam , The Netherlands
| | - Jan G P Tijssen
- a Department of Cardiology, Academic Medical Center , University of Amsterdam , Amsterdam , The Netherlands
| | - Barbara J M Mulder
- a Department of Cardiology, Academic Medical Center , University of Amsterdam , Amsterdam , The Netherlands.,c Interuniversity Cardiology Institute of the Netherlands (ICIN) , Utrecht , The Netherlands
| | - Robbert J de Winter
- a Department of Cardiology, Academic Medical Center , University of Amsterdam , Amsterdam , The Netherlands
| |
Collapse
|
8
|
Huang Y, Kong JF, Venkatraman SS. Biomaterials and design in occlusion devices for cardiac defects: a review. Acta Biomater 2014; 10:1088-101. [PMID: 24334144 DOI: 10.1016/j.actbio.2013.12.003] [Citation(s) in RCA: 23] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2013] [Revised: 11/14/2013] [Accepted: 12/02/2013] [Indexed: 10/25/2022]
Abstract
This review examines the biomaterials used in occlusion devices for cardiac defects, and how the choice of these materials is dictated by design. Specifically, the devices used in three major applications, the atrial septal defect, the ventricular septal defect and the patent ductus arteriosus, are examined critically. A number of different devices are available, with varied performance in deployment and sealing. There is no device in any of the three categories that satisfies fully the range of requirements, and all have associated complications. The type and rate of complications are different among different devices. The short-term (immediate) complications are addressed by immediate retrieval. For longer-term complications, most of which can be fatal, currently only surgical retrieval and replacement are possible. Most of these longer-term complications can be alleviated by the use of fully degradable devices, which will eliminate concerns regarding the use of metals inside the heart, and if fully endothelialized, also minimize migration concerns. On the other hand, the lower moduli of currently available biodegradable materials need to be augmented. Improvements in the stiffness required for deployment can be accomplished with the use of fillers, nano- or micro-sized, and an example of this are radiopaque fillers.
Collapse
|
9
|
Abstract
Transcatheter closure of atrial septal defects has evolved significantly over the last 20 years. Transcatheter closure has replaced surgical closure for the treatment of most secundum atrial septal defectsat the current time. A major reason for this is the lower morbidity of transcatheter closure procedures. Several closure devices have come into clinical use. The Amplatzer septal occluder (AGA Medical Co.) currently has the largest reported experience and subsequently the best-established safety and efficacy features. Clinically challenging situations, such as larger atrial septal defects, atrial septal defects with deficient rims and multiple atrial septal defects, are increasingly being addressed using the transcatheter approach, with improved results. The incidence of most complications has significantly reduced over time, and serious side effects are relatively uncommon. In this review, the literature is summarized regarding the current role of transcatheter closure, the evolution of the different available devices for clinical use and the complications that occur with their use. A comparison is also made with surgical closure techniques.
Collapse
Affiliation(s)
- Anuja Gupta
- KEM Hospital, 48/49 Hatkesh Society, Road number 7, Juhu Scheme, Mumbai400 049, India.
| | | | | |
Collapse
|
10
|
|
11
|
Wei J, Hsiung MC, Tsai SK, Yin WH, Ou CH, Donmez C, Bicer E, Daly DD, Dumaswala B, Dumaswala K, McKay J, Nanda NC. Atrial Septal Occluder Device Embolization to an Iliac Artery: A Case Highlighting the Utility of Three-Dimensional Transesophageal Echocardiography during Percutaneous Closure. Echocardiography 2012; 29:1128-31. [DOI: 10.1111/j.1540-8175.2012.01793.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022] Open
Affiliation(s)
- Jeng Wei
- Heart Center; Cheng-Hsin Medical Center; Taipei; Taiwan; Republic of China
| | - Ming C. Hsiung
- Heart Center; Cheng-Hsin Medical Center; Taipei; Taiwan; Republic of China
| | - Shen Kou Tsai
- Heart Center; Cheng-Hsin Medical Center; Taipei; Taiwan; Republic of China
| | | | - Ching-Huei Ou
- Heart Center; Cheng-Hsin Medical Center; Taipei; Taiwan; Republic of China
| | - Cevdet Donmez
- Division of Cardiovascular Diseases; University of Alabama at Birmingham; Birmingham; Alabama
| | - Elif Bicer
- Division of Cardiovascular Diseases; University of Alabama at Birmingham; Birmingham; Alabama
| | - David D. Daly
- Division of Cardiovascular Diseases; University of Alabama at Birmingham; Birmingham; Alabama
| | - Bhavin Dumaswala
- Division of Cardiovascular Diseases; University of Alabama at Birmingham; Birmingham; Alabama
| | - Komal Dumaswala
- Division of Cardiovascular Diseases; University of Alabama at Birmingham; Birmingham; Alabama
| | - Joshua McKay
- Division of Cardiovascular Diseases; University of Alabama at Birmingham; Birmingham; Alabama
| | - Navin C. Nanda
- Division of Cardiovascular Diseases; University of Alabama at Birmingham; Birmingham; Alabama
| |
Collapse
|
12
|
Abstract
BACKGROUND There are concerns over the outcome of device closure of secundum atrial septal defect with special reference to erosions and aortic regurgitation. AIM To assess the medium-term outcome of device closure of atrial septal defects with special reference to complications. METHODS A total of 205 patients with secundum atrial septal defects underwent transcatheter closure from October, 1999 to April, 2009. The median age was 18 (1.4-55) years. Amplatzer Septal Occluder was used in all the patients. Medium-term follow-up was available in 176 of 200 (88%) patients. RESULTS Device closure was successful in 200 out of 205 (98%) patients. The device embolised in four patients and was associated with short inferior caval vein margin (p = 0.003). Balloon sizing in 71 patients (35%) resulted in implantation of a larger device (p = 0.002). Early complications included pericardial effusion, 2:1 heart block, and infective endocarditis (1 patient each). There were eight patients who reported migraine (3.9%). At median follow-up of 5.8 (0.6-10.3) years, complete closure occurred in 197 out of 200 patients. Short superior caval vein margin was associated with a residual shunt (p < 0.001). There were two patients who developed mild aortic regurgitation (1%), which correlated with a device-to-defect ratio of >1.3:1 (p = 0.001). There were no erosions, late embolisation, or thromboembolism. Atrial fibrillation occurred in three adults (1.5%). CONCLUSIONS Device closure of secundum atrial septal defects using Amplatzer Septal Occluder is safe and effective in the medium term. Short inferior caval vein margin correlates with increased risk of embolisation and short superior caval vein margin with a residual shunt. The risk of developing aortic regurgitation is low and correlates with increased device-to-defect ratio.
Collapse
|
13
|
Intraoperative device closure of atrial septal defects with inferior vena cava rim deficiency: A safe alternative to surgical repair. J Thorac Cardiovasc Surg 2011; 141:631-6. [DOI: 10.1016/j.jtcvs.2010.07.077] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/16/2010] [Revised: 06/14/2010] [Accepted: 07/31/2010] [Indexed: 11/21/2022]
|
14
|
Cansel M, Pekdemir H, Yağmur J, Tasolar H, Ermis N, Kurtoglu E, Acıkgoz N, Atas H, Ozdemir R. Early single clinical experience with the new Figulla ASD Occluder for transcatheter closure of atrial septal defect in adults. Arch Cardiovasc Dis 2011; 104:155-60. [DOI: 10.1016/j.acvd.2010.12.006] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/13/2010] [Revised: 12/17/2010] [Accepted: 12/24/2010] [Indexed: 10/18/2022]
|
15
|
Jerath A, Jaura A, Karski J, Feindel C, Butany J, Vegas A. Left-sided migration of Sideris button atrial septal occluder device. EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY 2010; 11:E21. [PMID: 20097746 DOI: 10.1093/ejechocard/jep228] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
We report the case of a left-sided migrated 'Sideris button' atrial septal defect occlusion device 6 years post-implantation with a residual secundum atrial septal defect and left atrial mass. The aims of this case report are to highlight an uncommonly seen atrial septal occlusion device, the importance of a complete echocardiographic examination of the path traversed by the device to assess for local trauma to structures, and the additional anatomical information gained and diagnostic use of intraoperative 3D transoesophageal echocardiography.
Collapse
Affiliation(s)
- Angela Jerath
- Department of Anesthesia and Pain Medicine, Toronto General Hospital, 200 Elizabeth Street, Toronto, Ontario, Canada M5G 2C4.
| | | | | | | | | | | |
Collapse
|
16
|
Qureshi AM, Mumtaz MA, Latson LA. Partial prolapse of a HELEX device associated with early frame fracture and mitral valve perforation. Catheter Cardiovasc Interv 2009; 74:777-82. [DOI: 10.1002/ccd.22081] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
17
|
Everett AD, Jennings J, Sibinga E, Owada C, Lim DS, Cheatham J, Holzer R, Ringewald J, Bandisode R, Ringel R. Community use of the amplatzer atrial septal defect occluder: results of the multicenter MAGIC atrial septal defect study. Pediatr Cardiol 2009; 30:240-7. [PMID: 19015911 DOI: 10.1007/s00246-008-9325-x] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/19/2008] [Revised: 09/11/2008] [Accepted: 10/18/2008] [Indexed: 11/25/2022]
Abstract
The objective of this study was to determine the initial safety and results of unrestricted multi-institution routine community use of the Amplatzer Septal Occluder (ASO) for atrial septal defect (ASD) closure. A multicenter, nonrandomized prospective study was performed in 13 pediatric cardiology centers from November 2004 to September 2007. Data were collected at the time of cardiac catheterization and 1 day postimplant. Four hundred seventy-eight patients underwent cardiac catheterization for ASO device closure of an ASD. The median age was 6 years (range, <1-83 years), and the mean weight was 37.2 kg (range, 2.6-148 kg). Procedural success was 96% (458/478 patients), with deficient rims being the major single reason for failed implantation (9/20). Major and minor complication rates were 1.1% and 4.8%, respectively, and were not different between simple and complex ASD groups. Success at 24 h was 99.4% (333/335) in the simple ASD group and 100% (120/120) in the complex ASD group. The presence of large defects, the presence of multiple defects, the use of multiple devices, and a weight <8 kg were significantly associated with a residual shunt (small to moderate) at 24 h. In conclusion, the ASO device in routine clinical practice for simple and complex ASD closure has an immediate safety and effectiveness profile equal to that reported in the initial pivotal FDA trial for simple ASDs. Based on the evolution in care posed by the ASO and the lack of consensus on patient selection in complex ASDs, this study points out the need to redefine the optimal patient and possibly broaden the indications for device closure of ASDs.
Collapse
Affiliation(s)
- Allen D Everett
- Department of Pediatrics, Johns Hopkins University, School of Medicine, Baltimore, MD 21287, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Majunke N, Bialkowski J, Wilson N, Szkutnik M, Kusa J, Baranowski A, Heinisch C, Ostermayer S, Wunderlich N, Sievert H. Closure of atrial septal defect with the Amplatzer septal occluder in adults. Am J Cardiol 2009; 103:550-4. [PMID: 19195519 DOI: 10.1016/j.amjcard.2008.10.018] [Citation(s) in RCA: 90] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/28/2008] [Revised: 10/23/2008] [Accepted: 10/23/2008] [Indexed: 11/25/2022]
Abstract
Transcatheter closure of atrial septal defects (ASDs) was performed mainly in children and adolescents. Information about outcome and complications in adults was limited. From November 1997 to November 2005, percutaneous closure of ASDs using the Amplatzer septal occluder was attempted in 650 consecutive adult patients. Median patient age was 45.8 +/- 16.2 years (range 18 to 90), mean systolic artery pressure was 33.3 +/- 10.6 mm Hg (range 11 to 85), and mean pulmonary and systemic blood flow (Qp/Qs) ratio was 1.9 +/- 0.7 (range 0.8 to 6.6). Mean stretched diameter of the ASD was 21.2 +/- 5.1 mm (range 3.1 to 43). Seventy-eight patients (12%) had multiple defects. Of 572 patients with a single ASD, device implantation was successful in 563 patients (98%). During follow-up, complete closure could be achieved in 96% of patients with a single ASD and 71% of patients with multiple defects. Mean systolic artery pressure decreased to 28.3 +/- 10.1 mm Hg and mean Qp/Qs ratio decreased to 1 +/- 0.3. The 3 complications that occurred during the procedure were device embolization (2 patients; 0.3%) and transient ST depression (1 patient; 0.2%). The most common complication immediately after the procedure and during follow-up was new-onset atrial fibrillation (28 patients; 4.3%). Electrical cardioversion was successfully in most. Complications requiring emergency or elective surgery occurred in 6 patients (0.9%; hemopericardium, 2 patients, 0.3%; device embolization, 3 patients, 0.5%, and pericardial tamponade, 1 patient, 0.2%). In conclusion, closure of ASDs using the Amplatzer septal occluder in adults was efficient and safe, with excellent long-term success rates. Serious complications were rare.
Collapse
|
19
|
Bartus S, Sorysz D, Siudak Z, Dubiel JS, Dudek D. Spontaneous closure of aorta-to-right atrium fistula after septal occluder implantation. J Cardiovasc Med (Hagerstown) 2008; 9:744-6. [DOI: 10.2459/jcm.0b013e3282f329e8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
20
|
Garg P, Walton AS. The New World of Cardiac Interventions: A Brief Review of the Recent Advances in Non-Coronary Percutaneous Interventions. Heart Lung Circ 2008; 17:186-99. [DOI: 10.1016/j.hlc.2007.10.019] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2007] [Revised: 10/24/2007] [Accepted: 10/29/2007] [Indexed: 12/11/2022]
|
21
|
Numan M, El Sisi A, Tofeig M, Gendi S, Tohami T, El-Said HG. Cribriform amplatzer device closure of fenestrated atrial septal defects: feasibility and technical aspects. Pediatr Cardiol 2008; 29:530-5. [PMID: 17999105 DOI: 10.1007/s00246-007-9079-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/30/2007] [Accepted: 06/28/2007] [Indexed: 11/28/2022]
Abstract
Fenestrated atrial septal defects (F-ASDs) may pose a challenge to device closure; recently, a cribriform device with a minimal connecting intrawaist diameter and large, equal left- and right-sided discs has been designed to cover more than one adjacent defect. This study demonstrates the feasibility and technical aspects of closing F-ASDs using this new device. Sixteen patients between August 2003 and January 2006 were included in this study. The inclusion criterion was the presence of a F-ASD diagnosed by transesophageal echocardiography. One of the three available cribriform ASD device sizes (18, 25, or 35 mm) was implanted. Patients were followed for at least 1 year after the procedure. Thirteen patients had successful cribriform ASD device implantation (median age and weight, 12.5 years and 36 kg, respectively). Ten patients (62%) had an associated atrial septal aneurysm. The mean procedure time was 75.6 +/- 28.5 min and the mean fluoroscopy time 14.8 +/- 6.3 min. The RVEDD was significantly reduced, from a mean of 24.2 mm to 21.0 (p < 0.05). One patient developed atrial tachycardia requiring cardioversion during the procedure. There were no embolic events, heart block, or mortality. Complete closure was 10 of 13 (77 %) the next day and 12 of 13 (92%) at 6 and 12 months. We conclude that the cribriform Amplatzer device can be successfully and safely used in patients with F-ASDs. Complete closure may take up to 6 months.
Collapse
|
22
|
Guan Z, Qin Y, Zhao X, Ding J, Zheng X, Nguyen V. Transcatheter closure of large atrial septal defects in 18 patients. Clin Cardiol 2008; 31:24-7. [PMID: 18203115 DOI: 10.1002/clc.20163] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/10/2022] Open
Abstract
PURPOSE This study was designed to evaluate the efficacy and safety of transcatheter closure of large atrial septal defects (ASD). METHODS Eighteen patients diagnosed as ostium secundum defect with a diameter of 30-40 mm were enrolled in this study. With the guidance of echocardiography and fluoroscopy, the Amplazter occlusion devices were implanted percutaneously through the femoral vein. RESULTS A small residual left-to-right shunt was detected with echocardiography immediately postprocedure but resolved after 1 week. The occlusion devices remained in proper position, and there was no residual shunt at 1- and 29-month follow-ups. Cardiac function and atrial sizes improved significantly as compared with the preclosure states. CONCLUSIONS Transcatheter closure of large atrial septal defects with the Amplazter occlusion device is feasible, safe and effective.
Collapse
Affiliation(s)
- Zhanjun Guan
- Division of Cardiology, Changhai Hospital, Second Military Medical University, Shanghai, PR China.
| | | | | | | | | | | |
Collapse
|
23
|
El-Sisi AM, Gendi S, Dilawar M, Numan M. Helex septal occluder: feasibility study of closure of atrial septal defect. Pediatr Cardiol 2008; 29:84-9. [PMID: 17899244 DOI: 10.1007/s00246-007-9053-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/23/2007] [Revised: 03/28/2007] [Accepted: 06/26/2007] [Indexed: 10/22/2022]
Abstract
BACKGROUND A variety of transcatheter atrial septal defect (ASD) occluders are currently in use, the most commonly used device is the Amplatzer Septal Occluder (ASO) yet there is no perfect device. The Helex Septal Occluder is a new device (by W.L. Gore & Associates, Inc.) designed to improve the results of transcatheter ASD closure. We report our first experience in closing secundum ASDs with this new device after its recent modifications. METHODS Thirteen patients were selected for Helex device closure with median age of 8 years (2.5-44 years) and median weight 30 Kg (12-96 Kg). Inclusion criteria were: small to moderate Secundum ASDs with sufficient rims by transthoracic echo (TTE) and confirmed by transoesophageal echo (TEE). Two cardiologists carried out the decision of device size. One of the five available Helex ASD device sizes was used (15-35 mm). Follow up TTE was performed the next day, one month, six months and one year later. RESULTS Twelve patients had successful Helex septal occluder implantation. One patient was switched to Cribriform ASD device during the procedure because of failure of the locking mechanism. Two patients had trivial residual left to right shunt which disappeared at one month follow up in one patient. No embolic event, AV block or mortality was observed. CONCLUSION This feasibility study of the novel Helex septal occluder after its recent modification showed that it can successfully and safely close well selected secundum ASDs. There are several advantages over the currently available devices.
Collapse
|
24
|
KIM MICHAELS, KLEIN ANDREWJ, CARROLL JOHND. Transcatheter Closure of Intracardiac Defects in Adults. J Interv Cardiol 2007; 20:524-45. [DOI: 10.1111/j.1540-8183.2007.00304.x] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
|
25
|
Ghosh S, Ghosh AK, Ghosh SK. Patent foramen ovale and atrial septal aneurysm in cryptogenic stroke. Postgrad Med J 2007; 83:173-7. [PMID: 17344571 PMCID: PMC2599987 DOI: 10.1136/pgmj.2006.051094] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
Up to 40% of acute ischaemic strokes in young adults are cryptogenic in nature, that is, no cause is determined. In more than half of these patients, patent foramen ovale (PFO) is seen along with an increased incidence of atrial septal aneurysm. The commonest method of investigation is echocardiography (preferably transoesophageal echocardiography). On the basis of available evidence, low risk patients are treated with antiplatelet agents and high risk patients with warfarin. There are inconclusive data on the efficacy of PFO closure to prevent stroke recurrence. However, if there is recurrent stroke or intolerance to medical therapy, percutaneous closure is carried out.
Collapse
Affiliation(s)
- Sujoy Ghosh
- Ayr Hospital, Dalmellington Road, Ayr, Ayrshire, UK
| | | | | |
Collapse
|
26
|
Orihashi K, Sueda T, Okada K, Imai K, Ban K, Hamamoto M. Real-time three dimensional echo-guided closure of atrial septal defect: an experimental model. Interact Cardiovasc Thorac Surg 2007; 4:391-5. [PMID: 17670439 DOI: 10.1510/icvts.2004.098160] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Abstract
Real-time 3D echo may open the way to off-pump closure of an atrial septal defect with a robotic surgery technique without remnant of closure device. We report the preliminary results of 3D echo-guided closure of defect in an experimental model. A sheet with an oval defect immersed in water was visualized with 3D echo as well as surgical instruments. The defect was closed under echo guidance. Visualization of objects and instruments, and feasibility and problems of this technique were examined. The defect was visualized like an endoscopic view. Changing the view point without moving the transducer was a unique advantage. Visualization of instruments was acceptable with the lowest gain level. Acoustic shadow was helpful for comprehending the spatial relationship among the objects. Position of needle entry could be confirmed by the movement of the sheet. As the defect was sutured, fold convergence appeared on the sheet. Difficulties were encountered in passing the needle between instruments because of echo dropout. The string was poorly visualized. 3D echo-guided suturing was feasible with adequate image quality. However, an improvement of the surface of instruments and a wider scanning area is necessary for achieving surgical procedures with more safety and reliability.
Collapse
Affiliation(s)
- Kazumasa Orihashi
- Division of Cardiovascular Surgery, Hiroshima University Hospital, Kasumi 1-2-3, Minami-ku, Hiroshima 734-8551, Japan.
| | | | | | | | | | | |
Collapse
|
27
|
|
28
|
Fu YC, Cao QL, Hijazi ZM. Device closure of large atrial septal defects: technical considerations. J Cardiovasc Med (Hagerstown) 2007; 8:30-3. [PMID: 17255813 DOI: 10.2459/01.jcm.0000247432.74699.47] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Transcatheter closure of secundum type atrial septal defect has become an accepted alternative to surgical closure. Closure of small to moderate-sized atrial septal defects is technically easy and straightforward, however, closure of large atrial septal defects may be technically challenging. We review the available techniques that can be used to secure deployment of the device in good position. These techniques include the use of a specially designed delivery sheath, the 'Hausdorf sheath', or deployment of the device in either right or left pulmonary veins, the use of a dilator or balloon to hold the left disk in the left atrium and the use of a Judkins right coronary guiding catheter to deploy the device.
Collapse
Affiliation(s)
- Yun-Ching Fu
- Section of Pediatric Cardiology, Department of Pediatrics, Taichung Veterans General Hospital and National Yang-Ming University, Taichung, Taiwan
| | | | | |
Collapse
|
29
|
Holzer RJ, Chisolm J, Hill SL, Cheatham JP. Transcatheter devices used in the management of patients with congenital heart disease. Expert Rev Med Devices 2006; 3:603-15. [PMID: 17064246 DOI: 10.1586/17434440.3.5.603] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The availability of transcatheter devices has revolutionized the management of patients with congenital heart and vascular disease. Many patients that were in the past exclusively treated through open heart surgical procedures can now be managed using a percutaneous approach. This article describes those devices that are, at present, most frequently used in the USA for transcatheter therapy of congenital heart disease, which have, or are about to receive, US premarket approval. It also focuses on devices for occlusion of septal defects and vascular structures, as well as endovascular stents. In addition, the most important outcome data are discussed.
Collapse
Affiliation(s)
- Ralf J Holzer
- Heart Center, Columbus Children's Hospital, 700 Children's Drive, Columbus, OH 43205, USA.
| | | | | | | |
Collapse
|
30
|
Nugent AW, Britt A, Gauvreau K, Piercey GE, Lock JE, Jenkins KJ. Device closure rates of simple atrial septal defects optimized by the STARFlex device. J Am Coll Cardiol 2006; 48:538-44. [PMID: 16875981 DOI: 10.1016/j.jacc.2006.03.049] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/25/2005] [Revised: 03/07/2006] [Accepted: 03/16/2006] [Indexed: 12/28/2022]
Abstract
OBJECTIVES This study sought to review the outcomes of 3 generations of closure devices for secundum atrial septal defects (ASDs) at a single institution. BACKGROUND Transcatheter closure of ASDs is now increasingly performed with devices that have been modified over time to improve performance. METHODS A review of prospective clinical trials of Clamshell (C.R. Bard Inc., Murray Hill, New Jersey), CardioSEAL (NMT Medical Inc., Boston, Massachusetts), and STARFlex (NMT Medical Inc.) closure devices for simple ASDs was performed. The entry criteria for these trials were age > or =2 years, isolated secundum ASD, evidence of right ventricular volume overload, and maximum stretched diameter varying from 20 to 25 mm. Successful outcomes were defined as no more than small residual leak (< or =2 mm) with absence of a severe complication or the need for an additional device or surgery. RESULTS A total of 72 Clamshell, 30 CardioSEAL, and 42 STARFlex devices were placed in uncomplicated ASDs. Each device modification resulted in improved closure rates, with the STARFlex device achieving a 93% complete closure rate with a device/stretched diameter ratio significantly smaller than with the other devices (p = 0.001). Severe complications occurred in 5 Clamshell, 1 CardioSEAL, and 0 STARFlex cases. Successful outcomes increased for each generation of device (79%, 93%, and 98% respectively, p = 0.009). There have been no long-term complications for either the CardioSEAL or the STARFlex devices. CONCLUSIONS Modifications in 3 generations of devices have resulted in improved results for percutaneous ASD closure.
Collapse
Affiliation(s)
- Alan W Nugent
- Department of Cardiology, Children's Hospital Boston, and Harvard Medical School, Boston, Massachusetts, USA.
| | | | | | | | | | | |
Collapse
|
31
|
Affiliation(s)
- Zahid Amin
- Joint Division of Pediatric Cardiology, University of Nebraska/Creighton University, Children's Hospital of Omaha, Nebraska, USA.
| |
Collapse
|
32
|
Cotts T, Strouse PJ, Graziano JN. Late migration of a Sideris buttoned device for occlusion of atrial septal defect. Catheter Cardiovasc Interv 2006; 68:754-7. [PMID: 17039528 DOI: 10.1002/ccd.20849] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
We describe a 17-year-old patient with an atrial septal defect who underwent device closure with a second generation Sideris buttoned device at 4 years of age. She presented 13 years after the procedure with the acute onset of chest discomfort, at which time a chest radiograph showed migration of the wire of the right atrial counter-occluder to the lateral aspect of the right atrial wall, with an associated right atrial perforation. The patient underwent uneventful surgical device retrieval and atrial septal defect closure. Late migration of a portion of the Sideris buttoned device can occur, suggesting the need for continued follow up, and a high index of suspicion for device failure should a patient become symptomatic.
Collapse
Affiliation(s)
- Timothy Cotts
- Division of Pediatric Cardiology, Department of Pediatrics, C.S. Mott Children's Hospital, University of Michigan, Ann Arbor, Michigan, USA.
| | | | | |
Collapse
|
33
|
Kapadia SR. Patent foramen ovale closure: historical perspective. Cardiol Clin 2005; 23:73-83. [PMID: 15676270 DOI: 10.1016/j.ccl.2004.10.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
The work of the pioneers in PFO closure finally may evolve into a front-line therapy for secondary prevention of stroke in selected patients who have PFO and embolic events. Current implants, although new to most of interventional cardiology and neurology, are the result of years of steady, progressive work. It seems that PFOclosure is here to stay and will become a key element in a collaborative approach between cardiology and neurology in the treatment of embolic stroke. The advances in device technology may make PFO closure sufficiently safe, effective,and durable that it may become one of the most frequent catheter laboratory procedures to be performed.
Collapse
Affiliation(s)
- Samir R Kapadia
- Department of Cardiovascular Medicine, Cleveland Clinic Foundation, 9500 Euclid Avenue, F-25, Cleveland, OH 44195, USA.
| |
Collapse
|
34
|
Lee EY, Siegel MJ, Chu CM, Gutierrez FR, Kort HW. Amplatzer atrial septal defect occluder for pediatric patients: radiographic appearance. Radiology 2004; 233:471-6. [PMID: 15516619 DOI: 10.1148/radiol.2332031707] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
PURPOSE To describe the chest radiographic appearance of the Amplatzer septal occluder (ASO) (AGA Medical Corporation, Golden Valley, Minn) for atrial septal defects (ASDs) in pediatric patients. MATERIALS AND METHODS Two radiologists independently reviewed frontal and lateral chest radiographs obtained in young patients 24 hours after transcatheter ASD closure with the ASO. The appearance (flat disks or dots) and location of the ASO were recorded. The location was related to that of a thoracic vertebral body on frontal and lateral chest radiographs and to a line drawn between the anterior margin of the right hilum and the posterior margin of the inferior vena cava (hilar-caval line) on lateral radiographs; this line corresponded to the expected position of the interatrial septum. The relationship between ASO appearance and patient age was assessed with logistic regression and cumulative probability plots. RESULTS Sixty-eight pediatric patients (age range, 1 month to 18 years; mean age, 4.2 years; 24 boys and 44 girls) were included. On frontal radiographs, the ASO center projected between T7 and T9, either to the right of or over the spinous processes of the vertebral body. On lateral radiographs, the ASO projected over (n = 66) or anterior to (n = 2) the hilar-caval line. On frontal radiographs, it appeared as one or two flat disks (n = 61) or as two metallic dots (n = 7). On lateral radiographs, it appeared as two flat disks (n = 54) or as two metallic dots (n = 14). The relationship between increasing patient age and the metallic dot appearance on frontal and lateral radiographs and on the combination of frontal and lateral radiographs was highly significant in each case (P < .001, likelihood ratio chi(2) test), with r(2) values of 0.35, 0.20, and 0.28, respectively. ASDs were successfully occluded with the ASO in all patients except one, in whom trivial shunting was seen at 12-month follow-up. CONCLUSION The ASO in pediatric patients has a characteristic radiographic appearance when properly positioned.
Collapse
Affiliation(s)
- Edward Y Lee
- Mallinckrodt Institute of Radiology, Washington University School of Medicine, 510 S Kingshighway Blvd, St Louis, MO 63110, USA
| | | | | | | | | |
Collapse
|
35
|
Bonaros N, Schachner T, Oehlinger A, Jonetzko P, Mueller S, Moes N, Kolbitsch C, Mair P, Putz G, Laufer G, Bonatti J. Experience on the Way to Totally Endoscopic Atrial Septal Defect Repair. Heart Surg Forum 2004; 7:E440-5. [PMID: 15799920 DOI: 10.1532/hsf98.20041098] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
Abstract
BACKGROUND Remote-access perfusion and robotics have enabled totally endoscopic closure of atrial septal defect (ASD) and patent foramen ovale (PFO). We report on a stepwise approach to a totally endoscopic procedure. METHODS Seventeen patients (median age, 39 years; range, 21-55 years) underwent limited-access ASD or PFO closure. As a preparative step, the operation was carried out through minithoracotomy in 11 patients. In parallel, experience with robotic surgery was gained with totally endoscopic coronary artery bypass grafting procedures. After performance of ASD closures in dry-laboratory models using the da Vinci telemanipulation system, 6 patients were operated on in a totally endoscopic fashion. RESULTS With the endoscopic approach, significant learning curves were noted for cardiopulmonary bypass time y(min) = 226 - 41 * ln(x) (P = .03) and aortic cross-clamp time y(min) = 134 - 42 * ln(x) (P = .01) (x = number of procedures). There was no hospital mortality, and no residual shunts were detected at postoperative echocardiography. Median ventilation time was 9 hours (range, 0-18 hours) for the minithoracotomy group and 6 hours (range, 4-19 hours) for the totally endoscopic group. Median intensive care unit stay was 20 hours (range, 18-24 hours) and 18 hours (range, 18- 120 hours), respectively. CONCLUSIONS The implementation of robotic totally endoscopic closure of ASD or PFO in a heart surgery program seems to be safe. An intermediate step of performing the operations through minithoracotomy, adapting to remote access perfusion systems, and gaining experience in other robotic cardiac surgical procedures seems worthwhile. Learning curves are apparent, and adequate defect closure does not seem to be compromised by the totally endoscopic approach.
Collapse
Affiliation(s)
- Nikolaos Bonaros
- Department of Cardiac Surgery, Medical University of Innsbruck, Innsbruck, Austria
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
36
|
Wang JK, Tsai SK, Wu MH, Lin MT, Lue HC. Short- and intermediate-term results of transcatheter closure of atrial septal defect with the Amplatzer Septal Occluder. Am Heart J 2004; 148:511-7. [PMID: 15389241 DOI: 10.1016/j.ahj.2004.01.030] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
BACKGROUND The Amplatzer Septal Occluder (ASO) (AGA Medical Corp, Golden Valley, Minn) has gained wide acceptance for transcatheter closure of atrial septal defect (ASD). We conducted this study to evaluate the short-and intermediate-term results of ASD closure with the ASO and to determine the impact of deficient rim on the results. METHODS Between March 1999 and February 2003, 197 patients underwent attempted transcatheter closure of ASD with the ASO. The size of the selected device either equaled or was 1 to 2 mm larger than the stretched diameter of the defect. Transesophageal echocardiography was used to monitor the implantation procedure. One hundred and fourteen patients (58%) with a deficiency in 1 rim (<5 mm) were included as group I, and the remaining 83 patients with adequate rims comprised group II. RESULTS The mean stretched diameter measured with the balloon catheter was 18.6 +/- 6.7 mm (range 7.1-37.2 mm). Deployment of the ASO was successful in 191 (97%) patients and failed in 6. There was no significant difference between the 2 groups in the success rate for ASD closure (110/114 vs 81/83). Repositioning of the device was required in 28 patients: 21 in group I and 7 in group II (21/114 vs 7/83, P >.05) The mean stretched diameter of the defect in these 28 patients was significantly larger than that in those who did not require repositioning of the device (27.3 +/- 5.7 vs 17.1 +/- 5.5 mm, P <.01). Three patients experienced severe complications: 1 had transient complete atrioventricular block, 1 had tamponade requiring drainage, and 1 had dislodgement of the device requiring emergent operation. One had a distal embolism to a fingertip. Echocardiography at 1 day, 3 months, 6 months, 12 months, and 24 months after the procedure showed residual shunts in 37/191 (19%), 15/189 (8%), 11/176 (6%), 7/131 (5%), and 3/72 (4%) patients, respectively. CONCLUSIONS The ASO is a safe and effective device for the transcatheter closure of ASD. Deficiency in 1 rim, particularly the superior anterior rim, does not influence the success rate of ASD closure.
Collapse
Affiliation(s)
- Jou-Kou Wang
- Department of Pediatrics, National Taiwan University Hospital, School of Medicine, National Taiwan University, Taipei, Taiwan
| | | | | | | | | |
Collapse
|
37
|
Anzai H, Child J, Natterson B, Krivokapich J, Fishbein MC, Chan VK, Tobis JM. Incidence of thrombus formation on the CardioSEAL and the Amplatzer interatrial closure devices. Am J Cardiol 2004; 93:426-31. [PMID: 14969615 DOI: 10.1016/j.amjcard.2003.10.036] [Citation(s) in RCA: 84] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/02/2003] [Revised: 10/10/2003] [Accepted: 10/10/2003] [Indexed: 12/28/2022]
Abstract
Transcatheter closure for atrial septal defect (ASD) and patent foramen ovale (PFO) is a promising alternative to surgical closure or anticoagulant therapy. A potential complication is thrombus formation on the device after implantation. From February 2001 to June 2003, 66 patients with atrial communication were treated successfully with the Amplatzer device (16 septal and 20 PFO occluders) or the CardioSEAL device (30). Patients were discharged on antiplatelet medication (aspirin and clopidogrel) and/or anticoagulation. Fifty patients (76%) had transesophageal echocardiography (TEE) 1 month after device implantation (28 +/- 10 days). No patient experienced a thromboembolic episode during follow-up. TEE revealed that thrombus formation occurred more frequently on the CardioSEAL device (5 of 23 patients; 22%) than on the Amplatzer device (0 of 27 patients; 0%) (p = 0.02). Although thrombus disappeared or markedly diminished after additional anticoagulation therapy in 3 patients, 1 patient had surgical explantation of the device due to progressive increase in the size of thrombus with hypermobility despite intensive anticoagulation therapy. There was no variable associated with the presence of thrombus formation on the occluder other than the use of the CardioSEAL device. One month after insertion, the CardioSEAL device is more likely to have thrombus present than the Amplatzer device.
Collapse
Affiliation(s)
- Hitoshi Anzai
- University of California, Los Angeles, Center for Health Sciences, Los Angeles, California 90095, USA
| | | | | | | | | | | | | |
Collapse
|
38
|
Kay JD, O'Laughlin MP, Ito K, Wang A, Bashore TM, Harrison JK. Five-year clinical and echocardiographic evaluation of the Das AngelWings atrial septal occluder. Am Heart J 2004; 147:361-8. [PMID: 14760337 DOI: 10.1016/j.ahj.2003.07.018] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
BACKGROUND The late outcome of patients treated with atrial septal occluder devices remains incompletely defined. The purpose of this study was to assess the late outcome (range 4-7 years postprocedure) of patients in whom the Das AngelWings septal occluder device was implanted in the atrial septum. We report the clinical and echocardiographic outcome, at an average of 5 years following the procedure, of patients treated with the Das AngelWings device used to close either a secundum atrial septal defect (ASD) or a patent foramen ovale (PFO). METHODS Thirty-two patients underwent successful percutaneous closure of an atrial septal closure, patent foramen ovale, or fenestration in the lateral tunnel of their Fontan with the Das AngelWings device between June 1995 and March 1998 at Duke University Medical Center. Two of the 32 patients were lost to follow-up. The remaining 30 patients were divided into 3 groups based on indication for device implantation. Group 1 consisted of 14 patients with a secundum ASD and predominantly left-to-right atrial shunting. Group 2 consisted of 8 patients who had a PFO and who suffered a thromboembolic event. Group 3 (compassionate use) consisted of 10 patients with multiple comorbid medical problems with predominantly right-to-left shunting at the atrial level causing hypoxemia. Eight of the patients in group 3 were severely ill at the time of device implantation. The 2 remaining patients in group 3 underwent AngelWings implantation for closure of right-to-left shunting through a Fontan fenestration. Mean follow-up was 59 months. RESULTS There was no device embolization. No patient in the ASD or PFO/stroke group had a clinical complication. By radiographic examination, 2 of 27 patients had evidence of fracture of the nitinol framework at 2-year follow-up. Residual shunting was present in 44% at 24 hours, 20% at 1 year, and 18.8% at 2 years by use of Doppler color flow imaging and/or microcavitation echocardiographic studies. Mild mitral regurgitation caused by the AngelWings device occurred in 1 patient. One patient in the compassionate use group had a subsequent neurologic event. Five of the 10 patients in the compassionate use group died of comorbid illnesses in follow-up, none directly related to device complications. CONCLUSION The late clinical outcome of secundum ASD and PFO/stroke patients in this study demonstrates that Das AngelWings closure of the atrial septum is effective and safe. These data are encouraging with respect to the expanding use of other percutaneously implanted ASD occlusion devices, although late clinical safety and efficacy data are needed for the specific devices being implanted.
Collapse
Affiliation(s)
- Joseph D Kay
- Department of Medicine, Division of Cardiology, Duke University Medical Center, Durham, NC 27710, USA
| | | | | | | | | | | |
Collapse
|
39
|
Earing MG, Cabalka AK, Seward JB, Bruce CJ, Reeder GS, Hagler DJ. Intracardiac echocardiographic guidance during transcatheter device closure of atrial septal defect and patent foramen ovale. Mayo Clin Proc 2004; 79:24-34. [PMID: 14708945 DOI: 10.4065/79.1.24] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
OBJECTIVES To describe our experience with intracardiac echocardiographic (ICE) guidance during transcatheter device closure of atrial septal defect (ASD) and patent foramen ovale (PFO) and to describe a detailed stepwise approach for performing ICE examinations. PATIENTS AND METHODS We reviewed the ICE results of all patients who underwent transcatheter device closure of ASD/PFO at the Mayo Clinic in Rochester, Minn, between October 2000 and November 2002. Conscious sedation was used, and all ICE studies were performed using a diagnostic ultrasound catheter. RESULTS Ninety-four patients (47 male; median age, 51 years [range, 17-81 years]) underwent ICE during transcatheter device closure of ASD/PFO. Total procedure time was 128 minutes (range, 27-320 minutes). ICE identified a previously unrecognized anatomical diagnosis in 32 of 94 patients. An additional ASD or PFO was found in 16 patients; a redundant atrial septum or an atrial septal aneurysm was found in 12 patients. There were few ICE complications (4%): 3 patients developed atrial fibrillation, and 1 developed supraventricular tachycardia; of these 4, 2 resolved spontaneously, and 2 required cardioversion with no recurrence. CONCLUSION ICE provides anatomical detail of ASD/PFO and cardiac structures facilitating congenital cardiac interventional procedures. ICE eliminates major drawbacks related to the use of transesophageal echocardiographic guidance for transcatheter device closure of ASD/PFO, specifically problems related to airway management. Finally, ICE gives the interventional cardiologist the ability to control all aspects of imaging without relying on additional echocardiographic support. We believe that ICE should be considered the preferred imaging technique for guidance of transcatheter device closure of ASD/PFO in adults and larger pediatric patients.
Collapse
MESH Headings
- Adolescent
- Adult
- Aged
- Aged, 80 and over
- Atrial Fibrillation/etiology
- Balloon Occlusion/adverse effects
- Balloon Occlusion/methods
- Echocardiography, Doppler, Color
- Echocardiography, Doppler, Pulsed
- Echocardiography, Transesophageal/adverse effects
- Echocardiography, Transesophageal/methods
- Female
- Heart Aneurysm/diagnostic imaging
- Heart Aneurysm/therapy
- Heart Atria/diagnostic imaging
- Heart Septal Defects, Atrial/diagnostic imaging
- Heart Septal Defects, Atrial/therapy
- Humans
- Male
- Middle Aged
- Tachycardia, Supraventricular/etiology
- Treatment Outcome
Collapse
Affiliation(s)
- Michael G Earing
- Division of Pediatric Cardiology, Mayo Clinic College of Medicine, Rochester, Minn 55905, USA
| | | | | | | | | | | |
Collapse
|
40
|
Dalvi BV, Pinto RJ, Gupta A. New technique for device closure of large atrial septal defects. Catheter Cardiovasc Interv 2004; 64:102-7. [PMID: 15619315 DOI: 10.1002/ccd.20248] [Citation(s) in RCA: 61] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
The objective of this study was to describe a new technique for transcatheter device closure of large atrial septal defects (ASDs) using the Amplatzer septal occluder and our experience with this technique in 14 patients. Transcatheter closure of large (> 25 mm) ASDs is challenging. We have developed a balloon-assisted technique (BAT) to facilitate device closure of large ASDs. The BAT consists of using a balloon catheter to support the left atrial (LA) disk of the Amplatzer septal occluder during device deployment. The balloon support prevents prolapse of the LA disk into the right atrium. Between April 2003 and February 2004, 14 patients with large ASDs (mean age, 25.71 +/- 15.71 years; mean weight, 51.21 +/- 23.78 kg) underwent device closure with the Amplatzer septal occluder using the BAT. The median balloon-stretched diameter of the ASD was 32 (range, 26-40) mm. The median device size used was 33 mm (range, 26-40 mm). All 14 patients had successful deployment of the device using the BAT. The mean follow-up period was 16.5 +/- 11.95 weeks. No major complications were noted during the procedure or on short-term follow-up. The BAT enables predictably successful closure of large ASDs using the Amplatzer septal occluder.
Collapse
|
41
|
Abstract
The first nonoperative ASD closure was performed by Noel L. Mills and Terry D. King in a 17-year old female patient on April 8, 1975. In the following years there was little interest in this clinical field after trials with the "Clamshell Device" had been discontinued because of arm fractures. From the late 1980s until the mid 1990s E. B. Sideris ("Buttoned Device") and U.U. Babic ("ASDOS") kept the ideas of King & Mills alive while G.S. Das developed the first self-centering device ("AngelWings"). Clinical trials with ASDOS and AngelWings have been stopped because of complicated technology and risk of perforation. The Buttoned Device and its modifications are still used with high success rates even in defects > 20 mm and low long-term risk of perforation. Since the pioneering works of King & Mills marked improvements in devices and delivery systems have been achieved. After almost three decades of ongoing research and development, transcatheter ASD closure has become a clinical routine procedure.
Collapse
Affiliation(s)
- Rainer Schräder
- Medizinische Klinik III-CCB, Markuskrankenhaus, Wilhelm-Epstein-Strasse 2, D-60431 Frankfurt am Main, Germany.
| |
Collapse
|
42
|
Mills NL, King TD. Late follow-up of nonoperative closure of secundum atrial septal defects using the King-Mills double-umbrella device. Am J Cardiol 2003; 92:353-5. [PMID: 12888154 DOI: 10.1016/s0002-9149(03)00647-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
There has been a marked increase in device closure of secundum atrial septal defects (ASDs) in the last decade. No clinical reports of late results have been forthcoming until now. The purpose of this report was to provide very long-term follow-up of nonoperative closure of secundum ADSs using the King-Mills Umbrella device. ASD closure using this technique did not appear to protect against the known secundum ASD complication of atrial arrhythmia. Twenty-seven-year follow-up of the umbrella ASD closure via the femoral vein shows effective occlusion, absence of device complications, and no reinterventions.
Collapse
Affiliation(s)
- Noel L Mills
- The Department of Surgery, Tulane University Medical School, New Orleans 70112, USA.
| | | |
Collapse
|
43
|
Moore J, Doyle TP. Interventional catheter therapy in adults with congenital heart disease. PROGRESS IN PEDIATRIC CARDIOLOGY 2003. [DOI: 10.1016/s1058-9813(03)00013-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
44
|
|
45
|
Pees C, Haas NA, von der Beek J, Ewert P, Berger F, Lange PE. Cardiac troponin I is increased after interventional closure of atrial septal defects. Catheter Cardiovasc Interv 2003; 58:124-9. [PMID: 12508215 DOI: 10.1002/ccd.10398] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Abstract
This study was designed to assess possible myocardial injury caused by interventional closure of atrial septal defects (ASDs) compared to diagnostic catheterization by measuring cardiac troponin I (cTn-I). Forty patients were enrolled; in 33 ASDs were successfully closed, while in 7 a diagnostic balloon sizing of the defect was performed only. Total cTn-I increased significantly from 0.1 to 1.9 microg/l at the end of the intervention and 2.23 at 4 hr and decreased to 1.35 at 15 hr. No significant increase could be detected in patients with diagnostic balloon sizing only or of CK/CK-MB levels either. Following interventional closure of ASDs with Amplatzer septum/PFO occluders, increased cTn-I levels for several hours indicate some transient, reversible myocardial membrane instability due to the device. Discrimination of ventricular myocardial infarction might be possible by estimating less sensitive CK and CK-MB levels only.
Collapse
Affiliation(s)
- Christiane Pees
- Department for Congenital Heart Defects and Pediatrics Cardiology, German Heart Center Berlin, Berlin, Germany.
| | | | | | | | | | | |
Collapse
|
46
|
Tamborini G, Pepi M, Susini F, Trabattoni D, Maltagliati A, Berna G, Onorato E, Bartorelli AL. Comparison of two- and three-dimensional transesophageal echocardiography in patients undergoing atrial septal closure with the amplatzer septal occluder. Am J Cardiol 2002; 90:1025-8. [PMID: 12398980 DOI: 10.1016/s0002-9149(02)02695-4] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Gloria Tamborini
- Centro Cardiologico Monzino, I.R.C.C.S, Institute of Cardiology, University of Milan, Milan, Italy.
| | | | | | | | | | | | | | | |
Collapse
|
47
|
Du ZD, Koenig P, Cao QL, Waight D, Heitschmidt M, Hijazi ZM. Comparison of transcatheter closure of secundum atrial septal defect using the Amplatzer septal occluder associated with deficient versus sufficient rims. Am J Cardiol 2002; 90:865-9. [PMID: 12372575 DOI: 10.1016/s0002-9149(02)02709-1] [Citation(s) in RCA: 115] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
To evaluate the feasibility of transcatheter closure of secundum atrial septal defects (ASDs) associated with deficient rims (<5 mm) using the Amplatzer septal occluder (ASO), 23 patients (median age 10.7 years) underwent an attempted transcatheter closure. The patients had a deficient anterior rim of 0 to 4 mm (n = 20), an inferior rim of 2 mm (n = 2), or a posterior rim of 4 mm (n = 1) as assessed by transesophageal echocardiography (TEE) or intracardiac echocardiography (ICE). Forty-eight patients with sufficient rims (>5 mm) who underwent closure served as controls. There were no differences between the 2 groups in ASD stretched diameter and device size (p >0.05). Of 23 patients with deficient rims, 17 (74%) had immediate complete closure compared with 44 of 48 patients (92%) with sufficient rims (p <0.05). At 24-hour and 6-month follow-up, the complete closure rates were not significantly different between the 2 groups (91% for patients with deficient rims vs 94% for patients with sufficient rims at 24 hours and 100% vs 93% at 6 months, respectively). The fluoroscopic time and procedure time were longer in patients with deficient rims (13 +/- 7 and 72 +/- 26 minutes, respectively) compared with those with sufficient rims (10 +/- 4 and 61 +/- 22 minutes, respectively). No major complications were encountered either during or after the closure procedure in both groups. Thus, transcatheter closure of ASDs associated with small anterior, inferior, or posterior rims is feasible using an ASO. Long-term follow-up data are still needed to assess long-term safety and efficacy.
Collapse
Affiliation(s)
- Zhong-Dong Du
- Section of Pediatric Cardiology, Department of Pediatrics, University of Chicago Children's Hospital and Pritzker School of Medicine, Chicago, Illinois 60637, USA
| | | | | | | | | | | |
Collapse
|
48
|
McMahon CJ, El Said HG, Mullins CE. Use of the transseptal puncture in transcatheter closure of long tunnel-type patent foramen ovale. Heart 2002; 88:E3. [PMID: 12117864 PMCID: PMC1767216 DOI: 10.1136/heart.88.2.e3] [Citation(s) in RCA: 19] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
Two patients with long tunnel-type patent foramen ovale presented for elective transcatheter closure following transient ischaemic attack and stroke. Right to left shunting was confirmed on transthoracic and transoesophageal echocardiography. A new technique that used a transseptal procedure was devised to enable closure of the tunnel-type patent foramen ovale using the CardioSEAL transseptal occluder to avoid "bunching up" of the device and residual transatrial shunting.
Collapse
Affiliation(s)
- C J McMahon
- Lillie Frank Abercrombie Division of Pediatric Cardiology, Texas Children's Hospital and Baylor College of Medicine, Houston, Texas, USA.
| | | | | |
Collapse
|
49
|
Du ZD, Cao QL, Rhodes J, Heitschmidt M, Hijazi ZM. Choice of device size and results of transcatheter closure of atrial septal defect using the amplatzer septal occluder. J Interv Cardiol 2002; 15:287-92. [PMID: 12238424 DOI: 10.1111/j.1540-8183.2002.tb01105.x] [Citation(s) in RCA: 43] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022] Open
Abstract
The impact of device size choice on closure results was analyzed in 138 (101 females, 37 males; age 0.5-84.0 years) consecutive patients who underwent transcatheter closure of the secundum atrial septal defect (ASD) using the Amplatzer septal occluder (ASO). The balloon stretched diameter (SD) of ASD was 19.5 +/- 7.2 mm in 123 patients with single defects, and 20.4 +/- 6.6 mm for the largest defects in 15 patients with multiple ASDs. The difference (delta) between ASO size chosen for closure and the stretched diameter of the defect was calculated and divided into groups: A (delta < -2 mm); B (delta -2.0 to -0.1 mm); C (delta = 0); D (delta 0.1-2.0 mm) and E (delta > 2 mm). The results demonstrated that immediate and 24-hour complete closure rates were significantly higher in patients in groups C and D (P < 0.001). However, at 6-month follow-up, the complete closure rates were similar in patients of groups A-D, while patients of group E had a lower closure rate of 75%. The complication rates were similar in all groups. In conclusion, a choice of a device size identical to or within 2 mm larger than the SD of the defect should be used to maximize the closure rates of ASD using the ASO.
Collapse
Affiliation(s)
- Zhong-Dong Du
- Section of Pediatric Cardiology, Department of Pediatrics, University of Chicago Children's Hospital, Pritzker School of Medicine, Chicago, Illinois, USA
| | | | | | | | | |
Collapse
|
50
|
Braun MU, Fassbender D, Schoen SP, Haass M, Schraeder R, Scholtz W, Strasser RH. Transcatheter closure of patent foramen ovale in patients with cerebral ischemia. J Am Coll Cardiol 2002; 39:2019-25. [PMID: 12084603 DOI: 10.1016/s0735-1097(02)01904-6] [Citation(s) in RCA: 138] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
OBJECTIVES The present study was conducted to determine the safety of the transcatheter closure of a patent foramen ovale (PFO) in patients with cryptogenic cerebral ischemia and the midterm follow-up of recurrent thromboembolic events after interventional PFO closure. BACKGROUND Current therapeutic options for stroke prevention in patients with PFO and a history of thromboembolic events include chronic antithrombotics and more invasive treatments such as surgical closure or minor invasive transcatheter permanent closure of the PFO. Promising preliminary and pilot data with the Amplatzer Septal Occluder or the PFO-Star Occluder have been reported. Systematic and long-term data are still missing. METHODS A total of 276 consecutive patients with a PFO and a history of at least one thromboembolic event were recruited in four medical centers and underwent percutaneous PFO closure with the PFO-Star device. Follow-up data were analyzed over an average of 15.1 months, equivalent to 345 patient-years. RESULTS The implantation was successful in all 276 patients. Peri-interventional reversible complications included transient ST-segment elevations (1.8%) and transient ischemic attack (TIA) (0.8%). Two devices have been removed surgically. During follow-up the annual recurrence rate of thromboembolic events was 1.7% for TIA, 0% for stroke and 0% for peripheral emboli. CONCLUSIONS Interventional PFO closure with the PFO-Star device appears to be a reliable and promising technique resulting in a low recurrence rate of thromboembolic events, especially stroke in patients with a history of cryptogenic ischemia presumably due to paradoxical embolization. To our knowledge, this is the largest coherent and prospective study for interventional PFO closure.
Collapse
Affiliation(s)
- Martin U Braun
- Department of Cardiology, University of Dresden, Dresden, Germany
| | | | | | | | | | | | | |
Collapse
|