1
|
Posterior Capsule Opacification after Cataract Surgery via Implantation with Hydrophobic Acrylic Lens Compared with Silicone Intraocular Lens: A Systematic Review and Meta-Analysis. J Ophthalmol 2022; 2022:3570399. [PMID: 35251708 PMCID: PMC8896947 DOI: 10.1155/2022/3570399] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2021] [Accepted: 01/26/2022] [Indexed: 11/18/2022] Open
Abstract
Hydrophobic acrylic intraocular lens (IOL) is the most popular material in cataract surgery. Posterior capsule opacification (PCO) is a long-term complication of cataract surgery. It can impair vision and adversely affect the prognosis of IOL delamination. The objective of this study was to perform a systematic review and meta-analysis to provide an updated evaluation of long-term complications and visual function after implantation with hydrophobic acrylic and silicone intraocular lenses. PubMed, Embase, and Cochrane Library were searched from January 2000 until March 2021. Randomized controlled trials (RCTs) and retrospective studies were finally included. The main outcomes were PCO value and neodymium-doped yttrium aluminum garnet (Nd : YAG) capsulotomy rate. Subgroup analysis was performed to compare hydrophobic acrylic and silicone IOLs during the follow-up period. Sensitivity analysis was also performed. The meta-analysis included a total of 17 studies. When the follow-up period was considered, the results of the analysis revealed higher PCO value (Group 3: standardized mean difference (SMD), −0.59; 95% confidence interval (CI), −0.90 to −0.28) and Nd : YAG capsulotomy rate (Group 3: risk ratio (RR), 0.60; 95% CI, 0.40–0.89) for hydrophobic acrylic IOLs than silicone IOLs during a long-term (≥6 years) follow-up. In conclusion, both the PCO value and the Nd : YAG capsulotomy rates were higher in hydrophobic acrylic IOLs group than the silicone IOLs group at long-term use (more than 6 years) after implantation.
Collapse
|
2
|
Oğurel T, Oğurel R, Gökçınar NB, Onaran Z, Örnek N, Örnek K. Comparison of the Neodymium-doped Yttrium Aluminum Garnet Capsulotomy Rate with Viscoimplantation and the Hydroimplantation Intraocular Lens Technique. KOREAN JOURNAL OF OPHTHALMOLOGY 2019; 33:222-227. [PMID: 31179653 PMCID: PMC6557793 DOI: 10.3341/kjo.2018.0122] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2018] [Revised: 01/03/2019] [Accepted: 01/12/2019] [Indexed: 11/23/2022] Open
Abstract
PURPOSE To investigate the rate of neodymium-doped yttrium aluminum garnet (Nd:YAG) laser capsulotomy in the hydroimplantation intraocular lens (IOL) technique. METHODS This retrospective study was comprised of 6,192 eyes in 3,790 patients who underwent surgery from January 2013 to September 2017 and then were followed up for at least 1 year. The eyes of these patients were divided into two groups: either viscoimplantation or hydroimplantation. The follow-up examinations were carried out on the 1st day, 4th day, 1st month, and 3 months to 1 year postoperatively. The Nd:YAG capsulotomy rates were evaluated by the different IOL implantation techniques and IOL materials. RESULTS The mean follow-up duration of the patients was in the viscoimplantation group 14.85 ± 2.43 and 15.05 ± 1.93 months in the hydroimplantation group. The Nd:YAG capsulotomy rate was significantly lower in the hydroimplantation group compared with the viscoimplantation group for the entire hydrophilic IOL model (p < 0.001). In addition, the Nd:YAG rate was lower in the hydroimplantation group that used a hydrophilic IOL than it was in the viscoimplantation group, which used a hydrophobic IOL. CONCLUSIONS The hydroimplantation technique reduced the Nd:YAG capsulotomy rate.
Collapse
Affiliation(s)
- Tevfik Oğurel
- Department of Ophthalmology, Kırıkkale University Medical Faculty, Kırıkkale, Turkey.
| | | | | | - Zafer Onaran
- Department of Ophthalmology, Kırıkkale University Medical Faculty, Kırıkkale, Turkey
| | - Nurgül Örnek
- Department of Ophthalmology, Kırıkkale University Medical Faculty, Kırıkkale, Turkey
| | | |
Collapse
|
3
|
Katsuki Y, Matsushima H, Mukai K, Watabiki S, Aose M, Terauchi W, Nagamoto T, Senoo T. Open-capsule intraocular lens to prevent posterior capsule opacification. J Cataract Refract Surg 2019; 45:1007-1012. [PMID: 30853319 DOI: 10.1016/j.jcrs.2018.12.022] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2018] [Revised: 12/17/2018] [Accepted: 12/18/2018] [Indexed: 11/24/2022]
Abstract
PURPOSE To develop a single-piece open-capsule intraocular lens (IOL) that can be inserted through a small incision and that prevents posterior capsule opacification (PCO) by expanding the capsule and circulating aqueous humor into the capsular bag. SETTING Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan. DESIGN Experimental study. METHOD Using the same hydrophobic acrylic material as the NY-60 IOL, a prototype open-capsule IOL was constructed. The IOL has a single optic and 2 haptics, with a 2.8 mm high spacer and holes through which aqueous humor circulates into the capsular bag by separating the anterior capsule from the posterior capsule and expanding the capsule. The open-capsule IOL or NY-60 (as a control group) was inserted in rabbit eyes. Posterior capsule opacification development was evaluated by measuring the thickness of the cell layer at the center of the posterior capsule on histopathologic specimens and statistically comparing the thickness between the open-capsule IOL group and control group. RESULTS The open-capsule IOL could be inserted through a 3.2 mm corneal incision using a D cartridge. The mean thickness of the cell layer at the center of the posterior capsule was 4.78 μm ± 2.61 (SD) in the open-capsule IOL group and 101.14 ± 25.19 μm in the control group and was significantly smaller in the open-capsule IOL group. CONCLUSION The prototype single-piece IOL could be implanted through a small incision and prevented PCO by expanding the lens capsule and circulating aqueous humor into the capsular bag.
Collapse
Affiliation(s)
- Yoko Katsuki
- Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan; HOYA Corporation Medical Division, Tokyo, Japan.
| | | | - Koichiro Mukai
- Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| | - Satoshi Watabiki
- Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| | - Masamoto Aose
- Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| | - Wataru Terauchi
- Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| | | | - Tadashi Senoo
- Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| |
Collapse
|
4
|
Application of Spectral Domain Optical Coherence Tomography to Objectively Evaluate Posterior Capsular Opacity In Vivo. J Ophthalmol 2019; 2018:5461784. [PMID: 30671258 PMCID: PMC6323435 DOI: 10.1155/2018/5461784] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2018] [Revised: 09/19/2018] [Accepted: 11/11/2018] [Indexed: 01/19/2023] Open
Abstract
Objectives To objectively evaluate posterior capsular opacification (PCO) with RTVue-100 spectral domain-OCT and assess the agreement with the Pentacam system. Methods Sixty-seven eyes diagnosed with PCO were included. RTVue-100 SD-OCT was used to scan the IOL outline and PCO at horizontal and vertical meridians. PCO was also imaged with a Pentacam and slit-lamp photography system. With RTVue-100 SD-OCT, the PCO area, thickness, density, and objective scores were recorded and used to evaluate the severity of PCO at 3 mm and 5 mm diameter ranges of the IOL optic region. We assessed the correlation of visual acuity, PCO characteristics, and PCO scores. PCO scores acquired from RTVue-100 SD-OCT images were also compared with those from the Pentacam. Differences between pear-type and fibrosis-type PCOs were also compared using RTVue-100 SD-OCT cross-sectional images. Results The cross-sectional images of PCO acquired with RTVue-100 SD-OCT corresponded well to Pentacam and slit-lamp retroillumination images. IOL-posterior capsular space, area, thickness, and density of the proliferated and accumulated LECs could be clearly visualized and quantified with RTVue-100 SD-OCT. PCO scores were correlated with decreased visual acuity, which was in line with the outcomes using the Pentacam. Differences between the pear-type and fibrosis-type PCO were statistically significant; pear-type PCOs showed a wider and thicker opacification region with lower density compared with fibrosis-type PCOs. Conclusion RTVue-100 SD-OCT could be a powerful tool in PCO objective evaluation and classification. OCT could be used to visualize the morphology and outline of PCO. Thus, it could discriminate and quantify differences between different types of PCO. PCO scores seem to be a useful factor that could reliably reflect PCO severity.
Collapse
|
5
|
Von Tress M, Marotta JS, Lane SS, Sarangapani R. A meta-analysis of Nd:YAG capsulotomy rates for two hydrophobic intraocular lens materials. Clin Ophthalmol 2018; 12:1125-1136. [PMID: 29950808 PMCID: PMC6018849 DOI: 10.2147/opth.s161380] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
Purpose The purpose of this study is to estimate and compare neodymium-doped yttrium aluminum garnet (Nd:YAG) capsulotomy rates for AcrySof ® and Clareon® intraocular lens (IOL) materials using historical data from the medical literature and Alcon-sponsored clinical studies. Methods Clinical trials that involved the implantation of AcrySof or Clareon monofocal IOLs in subjects with cataract or presbyopia were extracted from the literature and a company repository of clinical studies. The study duration, number of eyes, and cumulative percent of Nd:YAGs for posterior capsule opacification were extracted. Bayesian random effects meta-analyses were conducted to estimate and compare outcomes for the 2 different IOL materials. Results A Bayesian random effects, meta-analysis was performed that combined a literature review of published AcrySof Nd:YAG posterior capsulotomy rates and Nd:YAG rates observed in Alcon-sponsored clinical studies of AcrySof and Clareon. Sixteen Alcon studies contained Nd:YAG data suitable for meta-analysis. Three of these Alcon studies contained results for the Clareon material (2 one-year studies, and 1 three-year study). The literature review included 50 papers from 1998 to 2015. In combination, 30,891 eyes were available for analysis and 2040 Nd:YAG procedures were reported in studies with a follow-up duration ranging in length from 4 months to 10 years. The overall probability of performing a Nd:YAG capsulotomy within a year of implant for AcrySof was 1.44% (1.11% to 1.83%) and 0.62% (0.21% to 1.38%) for Clareon. There was small improvement in the probability of Nd:YAG within a year of implant for Clareon lenses of about 0.82% with a 95% credible interval of (0.07% to 1.36%) at 1 year. Results were similar for incidence rates per 100 surgeries in a year: 0.62 (0.21 to 1.40) for Clareon, 1.46 (1.12 to 1.87) for AcrySof, and the difference was 0.84 (0.07 to 1.39) favoring Clareon. At 3 years, the overall probability of performing a Nd:YAG capsulotomy for AcrySof was 4.19% (3.24% to 5.30%) compared with only 1.82% (0.63% to 4.02%) for Clareon. Conclusion A meta-analysis of Clareon multi-piece and single-piece clinical data predicts that the cumulative Clareon Nd:YAG probability will be ≤ AcrySof by 2.37% (0.18% to 3.91%) at 3 years. The results indicate that Clareon is likely to perform as well as, and possibly better than, AcrySof in terms of Nd:YAG capsulotomy rates.
Collapse
Affiliation(s)
| | | | - Stephen S Lane
- Global Clinical Strategy, Alcon Laboratories, Fort Worth, TX, USA
| | | |
Collapse
|
6
|
Three-year incidence of Nd:YAG capsulotomy and posterior capsule opacification and its relationship to monofocal acrylic IOL biomaterial: a UK Real World Evidence study. Eye (Lond) 2018; 32:1579-1589. [PMID: 29891902 PMCID: PMC6189124 DOI: 10.1038/s41433-018-0131-2] [Citation(s) in RCA: 37] [Impact Index Per Article: 6.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Revised: 02/09/2018] [Accepted: 05/03/2018] [Indexed: 11/13/2022] Open
Abstract
Purpose To evaluate 3-year incidence of Nd:YAG capsulotomy and PCO and compare the effect of different IOL materials. Methods Data were retrospectively collected from seven UK ophthalmology clinics using Medisoft electronic medical records. Eyes from patients ≥65 years undergoing cataract surgery with implantation of acrylic monofocal IOLs during 2010–2013 and 3-year follow-up were analysed. Nd:YAG capsulotomy and PCO incidence proportions were reported for 3 IOL cohorts: AcrySof, other hydrophobic and hydrophilic acrylic IOLs. Unadjusted/adjusted odds ratios (OR) of Nd:YAG capsulotomy were calculated through logistic regression for non-AcrySof cohorts versus AcrySof. A sub-group analysis in single-piece IOLs (>90% of sample eyes) was also performed. Results The AcrySof cohort included 13,329 eyes, non-AcrySof hydrophobic 19,025 and non-AcrySof hydrophilic 19,808. The 3-year Nd:YAG capsulotomy incidence (95% CI) for AcrySof (2.4%, 2.2–2.7%) was approximately two times lower than non-AcrySof hydrophobic IOLs (4.4%, 4.1–4.7%) and approximately fourfold lower than non-AcrySof hydrophilic IOLs (10.9%, 10.5–11.3%). Trends were similar in PCO incidence (AcrySof: 4.7%; non-AcrySof hydrophobic: 6.3%; non-AcrySof hydrophilic: 14.8%). Also in the analysis restricted to single-piece IOLs, the pattern remained (2.4% vs 5.1% vs. 10.9%, respectively). Adjusted regression analysis showed a approximately two and fivefold increased odds of Nd:YAG for non-AcrySof hydrophobic and hydrophilic acrylic IOLs respectively vs. AcrySof IOLs. Nd:YAG capsulotomy ORs were similar and remained statistically significant in the single-piece IOL sub-group. Conclusions Real-world evidence shows that within 3 years following implantation, AcrySof IOLs are significantly superior in reducing Nd:YAG capsulotomy and PCO incidence compared to other hydrophilic and hydrophobic acrylic IOLs.
Collapse
|
7
|
Biomaterial Influence on Intraocular Lens Performance: An Overview. J Ophthalmol 2018; 2018:2687385. [PMID: 29736282 PMCID: PMC5874989 DOI: 10.1155/2018/2687385] [Citation(s) in RCA: 48] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2017] [Revised: 12/08/2017] [Accepted: 01/02/2018] [Indexed: 11/18/2022] Open
Abstract
There is strong evidence that the IOL material is the factor having the greatest impact on posterior capsule opacification (PCO), anterior capsule opacification (ACO) development, and glistening formation after cataract surgery, even though there are other IOL features—such as haptic material and design and edge and optic design—that also have some influence. We reviewed the published literature describing the adverse events that are mainly related to the intraocular lens (IOL) material, such as PCO, ACO, and the subsequent capsule contraction, as well as glistening formation. The adverse events presented in this overview are the most common ones in clinical practice, and therefore, they are generally included in the clinical protocols for IOL evaluation.
Collapse
|
8
|
Li X, Kelly D, Nolan JM, Dennison JL, Beatty S. The evidence informing the surgeon's selection of intraocular lens on the basis of light transmittance properties. Eye (Lond) 2016; 31:258-272. [PMID: 27935597 PMCID: PMC5306461 DOI: 10.1038/eye.2016.266] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2016] [Accepted: 09/27/2016] [Indexed: 01/01/2023] Open
Abstract
In recent years, manufacturers and distributors have promoted commercially available intraocular lenses (IOLs) with transmittance properties that filter visible short-wavelength (blue) light on the basis of a putative photoprotective effect. Systematic literature review. Out of 21 studies reporting on outcomes following implantation of blue-light-filtering IOLs (involving 8914 patients and 12 919 study eyes undergoing cataract surgery), the primary outcome was vision, sleep pattern, and photoprotection in 9 (42.9%), 9 (42.9%), and 3 (14.2%) respectively, and, of these, only 7 (33.3%) can be classed as high as level 2b (individual cohort study/low-quality randomized controlled trials), all other studies being classed as level 3b or lower. Of the level 2b studies, only one (14.3%) found in favor of blue-light-filtering IOLs vs ultraviolet (UV)-only filtering IOLs on the basis of an association between better post-operative contrast sensitivity (CS) at select frequencies with the former; however, that study did not measure or report CS preoperatively in either group, and the finding may simply reflect better preoperative CS in the eyes scheduled to be implanted with the blue-light-filtering IOL; moreover, that study failed to measure macular pigment, a natural preceptoral filter of blue-light, augmentation of which is now known to improve CS. In terms of photoprotection, there is no level 2b (or higher) evidence in support of blue filtering IOLs vs UV-only filtering IOLs. On the basis of currently available evidence, one cannot advocate for the use of blue-light-filtering IOLs over UV-only filtering IOLs.
Collapse
Affiliation(s)
- X Li
- Pharmaceutical & Molecular Biotechnology Research Centre, Department of Chemical & Life Sciences, Waterford Institute of Technology, Waterford, Ireland
| | - D Kelly
- Nutrition Research Centre Ireland, Macular Pigment Research Group, School of Health Science, Waterford Institute of Technology, Waterford, Ireland
| | - J M Nolan
- Nutrition Research Centre Ireland, Macular Pigment Research Group, School of Health Science, Waterford Institute of Technology, Waterford, Ireland
| | - J L Dennison
- Nutrition Research Centre Ireland, Macular Pigment Research Group, School of Health Science, Waterford Institute of Technology, Waterford, Ireland
| | - S Beatty
- Nutrition Research Centre Ireland, Macular Pigment Research Group, School of Health Science, Waterford Institute of Technology, Waterford, Ireland.,Institute of Vision Research, Whitfield Clinic, Waterford, Ireland
| |
Collapse
|
9
|
Chang P, Lin L, Zheng Q, Yu F, Yu X, Zhao Y, Ding X, Zhu W, Li J, Zhao YE. An Optical Section-Assisted In Vivo Rabbit Model for Capsular Bend and Posterior Capsule Opacification Investigation. PLoS One 2016; 11:e0148553. [PMID: 26840405 PMCID: PMC4739694 DOI: 10.1371/journal.pone.0148553] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2015] [Accepted: 01/20/2016] [Indexed: 12/02/2022] Open
Abstract
Purpose To establish an optical section-assisted in vivo rabbit model for capsular bend and posterior capsule opacification (PCO) investigation. Methods A total of 10 rabbits underwent phacoemulsification surgery and intraocular lens (IOL) implantation. On the basis of the relationship between the anterior capsule and IOL, the rabbits were divided into complete overlap and incomplete overlap groups, in which six and four rabbits were included, respectively. The capsular bend optical sections were assessed using ultra-long scan depth optical coherence tomography (UL-OCT), and posterior capsule opacification was evaluated with slit lamp on postoperative day 3, 7, 14, and 28. In addition, histopathological section was used to verify the accuracy of capsular bend type captured by OCT in three rabbits. Results Based on the special animal model, six capsular bend types were observed, namely, anterior (A), middle (M), posterior (P), detachment (D), funnel (Fun) and furcate adhesion (Fur). On day 3, capsular bend began to form. On 14 days, the capsular bends were comprised of A, M and D types, which were almost maintained until day 28. Histopathological section findings were consistent with optical sectioning results. In the incomplete and complete groups, the earliest PCO within the optical zone were on day 7 and 28, respectively. The incomplete group exhibited higher incidence and faster PCO on day 7 (p = 0.038) and 14 (p = 0.002). Conclusions This animal model not only mimics capsular bend evolution and PCO processes but also produces OCT optical section images equivalent to and more repeatable than histopathology, thereby providing a promising method for the further investigations of PCO.
Collapse
Affiliation(s)
- Pingjun Chang
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Lei Lin
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Qian Zheng
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Fang Yu
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Xiaoyu Yu
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Yinying Zhao
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Xixia Ding
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Weigen Zhu
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
| | - Jin Li
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
- * E-mail: ; (YEZ); (JL)
| | - Yun-e Zhao
- School of Ophthalmology and Optometry, Wenzhou Medical University, Wenzhou, Zhejiang, China
- * E-mail: ; (YEZ); (JL)
| |
Collapse
|
10
|
Choi M, Kim SY, Lee MY, Lee YC, Kim SY. Comparison of Nd:YAG Capsulotomy Rates between Hydrophobic and Hydrophilic Intraocular Lenses. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2016. [DOI: 10.3341/jkos.2016.57.7.1063] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Mihyun Choi
- Department of Ophthalmology and Visual Science, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea
| | - Sun Young Kim
- Department of Ophthalmology and Visual Science, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea
| | - Mee Yon Lee
- Department of Ophthalmology and Visual Science, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea
| | - Young-Chun Lee
- Department of Ophthalmology and Visual Science, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea
| | - Su-Young Kim
- Department of Ophthalmology and Visual Science, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Uijeongbu, Korea
| |
Collapse
|
11
|
Praveen MR, Shah GD, Vasavada AR, Dave KH. The effect of single-piece hydrophobic acrylic intraocular lenses on the development of posterior capsule opacification. Am J Ophthalmol 2015; 160:470-478.e1. [PMID: 26067189 DOI: 10.1016/j.ajo.2015.05.037] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2015] [Revised: 05/29/2015] [Accepted: 05/29/2015] [Indexed: 11/17/2022]
Abstract
PURPOSE To evaluate the long-term effect of a single-piece hydrophobic acrylic intraocular lens (IOL), AcrySof SN60AT (Alcon Laboratories, Fort Worth, Texas, USA), on the development of posterior capsule opacification (PCO) 5 years postoperatively. DESIGN Prospective, observational, consecutive, case series. METHODS setting: Iladevi Cataract and IOL Research Center, Ahmedabad, India. STUDY POPULATION Three hundred and ninety eyes with uncomplicated age-related cataract were included. Patients with diabetes mellitus, glaucoma, high myopia, pseudoexfoliation, traumatic cataract, subluxated cataract, previous ocular surgeries, and allergy to dilating drops were excluded. intervention procedures: Digital retroillumination photographic documentation was performed and analyzed for PCO using Evaluation of Posterior Capsule Opacification software. The scores and areas were calculated. MAIN OUTCOME MEASURES PCO development and the influence of the anterior capsule cover (total on and part on) on the IOL optic was studied within the capsulorrhexis margin and the central 3.0 mm optic area. RESULTS There was a significant increase in PCO up to 3 years. No significant change in PCO was observed between 3 and 5 years within the capsulorrhexis margin and central 3.0 mm optic area. In the total on group, within the capsulorrhexis margin, significantly lower scores and areas were observed when compared with part-on scores and areas. CONCLUSION The increase in PCO up to 3 years was significant. Stabilization in PCO was observed between 3 and 5 years with no difference at 5 years. There was a low incidence of PCO in eyes with total anterior capsule cover over the IOL optic.
Collapse
Affiliation(s)
- Mamidipudi R Praveen
- Iladevi Cataract & IOL Research Center, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India
| | - Gauri D Shah
- Iladevi Cataract & IOL Research Center, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India
| | - Abhay R Vasavada
- Iladevi Cataract & IOL Research Center, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India.
| | - Khyati H Dave
- Iladevi Cataract & IOL Research Center, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India
| |
Collapse
|
12
|
Wormstone IM, Eldred JA. Experimental models for posterior capsule opacification research. Exp Eye Res 2015; 142:2-12. [PMID: 25939555 DOI: 10.1016/j.exer.2015.04.021] [Citation(s) in RCA: 89] [Impact Index Per Article: 9.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2014] [Revised: 04/29/2015] [Accepted: 04/30/2015] [Indexed: 12/28/2022]
Abstract
Millions of people worldwide are blinded due to cataract formation. At present the only means of treating a cataract is through surgical intervention. A modern cataract operation involves the creation of an opening in the anterior lens capsule to allow access to the fibre cells, which are then removed. This leaves in place a capsular bag that comprises the remaining anterior capsule and the entire posterior capsule. In most cases, an intraocular lens is implanted into the capsular bag during surgery. This procedure initially generates good visual restoration, but unfortunately, residual lens epithelial cells undergo a wound-healing response invoked by surgery, which in time commonly results in a secondary loss of vision. This condition is known as posterior capsule opacification (PCO) and exhibits classical features of fibrosis, including hyperproliferation, migration, matrix deposition, matrix contraction and transdifferentiation into myofibroblasts. These changes alone can cause visual deterioration, but in a significant number of cases, fibre differentiation is also observed, which gives rise to Soemmering's ring and Elschnig's pearl formation. Elucidating the regulatory factors that govern these events is fundamental in the drive to develop future strategies to prevent or delay visual deterioration resulting from PCO. A range of experimental platforms are available for the study of PCO that range from in vivo animal models to in vitro human cell and tissue culture models. In the current review, we will highlight some of the experimental models used in PCO research and provide examples of key findings that have resulted from these approaches.
Collapse
Affiliation(s)
| | - Julie Ann Eldred
- School of Biological Sciences, University of East Anglia, Norwich NR4 7TJ, UK
| |
Collapse
|
13
|
Halili I, Mutlu FM, Erdurman FCN, Gündogan FC, Kilic S. Influence of capsular tension ring on posterior capsule opacification in myopic eyes. Indian J Ophthalmol 2015; 62:311-5. [PMID: 24008791 PMCID: PMC4061669 DOI: 10.4103/0301-4738.116469] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Purpose: To determine the effect of a capsular tension ring (CTR) implantation in preventing posterior capsular opacification (PCO) after cataract surgery in patients with high myopia. Materials and Methods: In this prospective single-surgeon standardized-surgical-procedure fellow-eye comparison trial, 34 patients with high myopia had phacoemulsification surgery. Although one eye received an acrylic intraocular lens (IOL) and CTR, other eye received only an IOL as control. PCO, within the capsulorhexis overlap, was documented by standardized digital retroillumination images at least 2 years post-operatively, and the percentage area of PCO was scored (scale 0%-100%) using the POCOman software system. The PCO score and the incidence of neodymium-doped yttrium aluminum garnet (Nd: YAG) capsulotomy of groups, and correlations between PCO score and presence of CTR, age, phaco time, refraction, and axial length (AL) were determined. Results: The mean time interval from surgery to PCO measurement was 43.4 ± 11.2 months for the eyes with a CTR and 43.1 ± 11.6 months for the controls (P = 0.91). The PCO score of the eyes with a CTR was significantly lower than in the controls (5.9 ± 4.3 vs. 22.3 ± 12.2, respectively; P < 0.001). There were statistically insignificant correlations between PCO score and pre-operative refraction (r = 0.02; P = 0.90), AL (r = 0.03; P = 0.80), phaco time (r = 0.11; P = 0.53), and patient's age (r = 0.23; P = 0.55). No patient with a CTR had a Nd: YAG laser capsulotomy, but it was six in controls (P = 0.025). Conclusions: CTR implantation seems to be effective in reducing the PCO and Nd: YAG laser capsulotomy rates in high myopic eyes.
Collapse
Affiliation(s)
- Ismail Halili
- Department of Ophthalmology, Central Military Hospital, Tirana, Albania
| | | | | | | | | |
Collapse
|
14
|
Kim SH, Park CY. Comparison of Nd:YAG Laser Capsulotomy Rates between Implantation of Two Different Aspheric Intraocular Lenses. JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY 2015. [DOI: 10.3341/jkos.2015.56.2.190] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
- Sung Hyun Kim
- Department of Ophthalmology, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang, Korea
| | - Choul Yong Park
- Department of Ophthalmology, Dongguk University Ilsan Hospital, Dongguk University College of Medicine, Goyang, Korea
| |
Collapse
|
15
|
Abstract
Posterior capsule opacification (PCO) is the most common complication after cataract surgery, with an incidence of 30%. It tends to be considered a normal event in the natural history of cataract surgery. Better understanding of its pathophysiology and advancement of intraocular lens material and design along with the improvement of phacoemulsification technique have contributed to decrease the incidence of PCO. Although treatment by Nd: YAG laser posterior capsulotomy is quick and non-invasive, the opening of the posterior capsule may be associated with numerous complications. Prevention remains the best measure for controlling this pathology.
Collapse
|
16
|
Hawlina G, Perovšek D, Drnovšek-Olup B, MoŽina J, Gregorčič P. Optical coherence tomography for an in-vivo study of posterior-capsule-opacification types and their influence on the total-pulse energy required for Nd:YAG capsulotomy: a case series. BMC Ophthalmol 2014; 14:131. [PMID: 25403826 PMCID: PMC4273457 DOI: 10.1186/1471-2415-14-131] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2013] [Accepted: 10/22/2014] [Indexed: 11/13/2022] Open
Abstract
Background Posterior capsule opacification (PCO) is the most common post-operative complication associated with cataract surgery and is mostly treated with Nd:YAG laser capsulotomy. Here, we demonstrate the use of high-resolution spectral-domain optical coherence tomography (OCT) as a technique for PCO analysis. Additionally, we evaluate the influence of PCO types and the distance between the intraocular lens (IOL) and the posterior capsule (PC), i.e., the IOL/PC distance, on the total-pulse energy required for the Nd:YAG laser posterior capsulotomy. Methods 47 eyes with PCO scheduled for the Nd:YAG procedure were examined and divided into four categories: fibrosis, pearl, mixed type and late-postoperative capsular bag distension syndrome. Using custom-made computer software for OCT image analysis, the IOL/PC distances in two dimensions were measured. The IOL/PC distances were compared with those of a control group of 15 eyes without PCO. The influence of the different PCO types and the IOL/PC distance on the total-pulse energy required for the Nd:YAG procedure was analyzed. Results The total-pulse energy required for a laser capsulotomy differs significantly between PCO types (p = 0.005, Kruskal-Wallis test). The highest energy was required for the fibrosis PCO type, followed by mixed, pearl and late-postoperative capsular bag distension syndrome. The IOL/PC distance also significantly influenced the total-pulse energy required for laser capsulotomy (p = 0.028, linear regression). Lower total-pulse energy was expected for a larger IOL/PC distance. Conclusions Our study indicates that the PCO types and the IOL/PC distance influence the total-pulse energy required for Nd:YAG capsulotomy. The presented OCT method has the potential to become an additional tool for PCO characterization. Our results are important for a better understanding of the photodisruptive mechanisms in Nd:YAG capsulotomy.
Collapse
Affiliation(s)
- Gregor Hawlina
- Eye Hospital, University Medical Centre Ljubljana, Grablovičeva 46, 1525 Ljubljana, Slovenia.
| | | | | | | | | |
Collapse
|
17
|
Aose M, Matsushima H, Mukai K, Katsuki Y, Gotoh N, Senoo T. Influence of intraocular lens implantation on anterior capsule contraction and posterior capsule opacification. J Cataract Refract Surg 2014; 40:2128-33. [PMID: 25458475 DOI: 10.1016/j.jcrs.2014.10.013] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2013] [Revised: 04/30/2014] [Accepted: 05/01/2014] [Indexed: 11/15/2022]
Abstract
PURPOSE To evaluate whether and how intraocular lens (IOL) implantation influences the development of anterior capsule contraction and posterior capsule opacification (PCO). SETTING Department of Ophthalmology, Dokkyo Medical University, Mibu, Tochigi, Japan. DESIGN Experimental study. METHODS Phacoemulsification was performed in 8-week-old white rabbits. A hydrophobic acrylate IOL (12.5 mm) (YA-60BBR) was implanted in 1 eye and no IOL was implanted in the fellow eye. Slitlamp microscopy and anterior segment analysis were performed to evaluate anterior capsule contraction after the surgery. Four weeks postoperatively, sections of the eyes were made, and the thickness of the proliferated lens epithelial cell (LEC) layer at the posterior capsule was measured to assess the PCO. In addition, LECs from white rabbits were cultured in medium containing 50% aqueous humor or in medium containing 50% saline to determine the influence of the aqueous humor on LECs and to compare the degree of LEC proliferation. RESULTS Starting 2 weeks after surgery, anterior capsule contraction progressed more significantly in the IOL group than in the group without IOLs. Four weeks postoperatively, LEC thickness at the posterior capsule was significantly less in the group without IOLs than in the IOL group. In the culture study, LEC proliferation was more inhibited in the aqueous humor group than in the saline group. CONCLUSIONS Progression of anterior capsule contraction and PCO is less likely in aphakic eyes than in IOL-implanted eyes. The mechanism of prevention may involve aqueous humor-induced inhibition of LEC proliferation.
Collapse
Affiliation(s)
- Masamoto Aose
- From the Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| | - Hiroyuki Matsushima
- From the Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan.
| | - Koichiro Mukai
- From the Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| | - Yoko Katsuki
- From the Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| | - Norihito Gotoh
- From the Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| | - Tadashi Senoo
- From the Department of Ophthalmology, Dokkyo Medical University, Tochigi, Japan
| |
Collapse
|
18
|
Vasavada AR, Praveen MR. Posterior Capsule Opacification After Phacoemulsification: Annual Review. Asia Pac J Ophthalmol (Phila) 2014; 3:235-40. [PMID: 26107764 DOI: 10.1097/apo.0000000000000080] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE The purpose of this article is to provide a clinical update on posterior capsule opacification (PCO) after phacoemulsification by reviewing the literature from the last 12 months. DESIGN This article is a literature review. METHODS The authors conducted a 1-year literature search in the English language on PCO using PubMed. The period used to conduct the literature search was from January 1, 2013, to January 1, 2014. The following search terms were used during the PubMed search: phacoemulsification, microcoaxial incision, posterior capsule opacification, long-term evaluation of intraocular lens (IOL) implantation, IOL edge design and material, surgical technique, anterior capsule overlap on the IOL optic, diabetes mellitus, myopia, pseudoexfoliation, retinitis pigmentosa, uveitis, and neodymium: yttrium-aluminum-garnet laser capsulotomy. RESULTS This review incorporates original articles that provided fresh insights and updates on PCO. Particular attention was paid to observational, randomized, controlled clinical trials, as well as analyses of larger cohorts with a prospective and retrospective study design. Letters to the editor, unpublished works, experimental trials and abstracts were not considered. CONCLUSIONS This annual review provides a brief update on PCO that might be of interest to the practicing clinical ophthalmologist.
Collapse
Affiliation(s)
- Abhay R Vasavada
- From the Iladevi Cataract and IOL Research Center, Raghudeep Eye Clinic, Ahmedabad, India
| | | |
Collapse
|
19
|
Hydrophobic acrylic versus polymethyl methacrylate intraocular lens implantation following cataract surgery in the first year of life. Graefes Arch Clin Exp Ophthalmol 2014; 252:1443-9. [PMID: 24947548 DOI: 10.1007/s00417-014-2689-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2014] [Revised: 05/25/2014] [Accepted: 05/28/2014] [Indexed: 12/25/2022] Open
Abstract
PURPOSE To evaluate complication rates following implantation of hydrophobic acrylic versus polymethyl methacrylate (PMMA) intraocular lens (IOL) with cataract surgery in infants. METHODS Records of children undergoing cataract surgery with IOL implantation in first year of life were retrospectively reviewed. Infants were divided into two groups--hydrophobic acrylic IOLs were implanted in group A, and PMMA IOLs in group B. Outcome measures included incidence of complications, additional surgical procedures, and refractive error changes. RESULTS One hundred and thirteen eyes of 113 children (75 males) with mean age of 6.49 ± 3.56 months were included. Group A included 62 eyes, and group B included 51 eyes. The two groups did not differ significantly in terms of age and axial length. There was no significant difference between the groups for incidence of posterior capsular opacification (PCO), pupillary membranes, glaucoma, fibrin on IOL surface or IOL malposition (p = 0.09). Development of PCO was delayed in group A (p = 0.049). Thirteen eyes of group A and 18 eyes of group B required additional surgical intervention (p = 0.20) in the follow-up visits. CONCLUSION Comparable complications may be expected in infants with PMMA and hydrophobic acrylic lenses. Children implanted with PMMA IOLs may require earlier surgical re-intervention for PCO.
Collapse
|
20
|
Matsushima H, Iwamoto H, Mukai K, Katsuki Y, Nagata M, Senoo T. Preventing secondary cataract and anterior capsule contraction by modification of intraocular lenses. Expert Rev Med Devices 2014; 5:197-207. [DOI: 10.1586/17434440.5.2.197] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
21
|
Rękas M, Kluś A, Kosatka M. Sealed-capsule irrigation with distilled deionized water to prevent posterior capsule opacification--prospective, randomized clinical trial. Curr Eye Res 2012; 38:363-70. [PMID: 23167738 DOI: 10.3109/02713683.2012.748079] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
PURPOSE To evaluate the efficacy and safety of sealed-capsule irrigation (SCI) using distilled water (DW) to prevent posterior capsule opacification (PCO). MATERIALS AND METHODS Phacoemulsification was performed in 60 patients. Patients were randomly selected into groups. In the control the capsular bag was mechanically cleaned (MC), in the DW group DW for 3' in SCI was additionally applied. SN60WF IOL was implanted in all eyes. Examinations were performed before and 1, 30, 180 days, one and two years after surgery. Uncorrected and corrected distance visual acuity (UDVA, CDVA), intraocular pressure (IOP), surgically induced astigmatism (K2-SIA), spherical equivalent (SEQ), endothelial cell and the complications were examined. Total PCO score in the area of 1 and 3 mm zone and capsulorhexis (CAPS) were determined using EPCO 2000. One patient was withdrawn from the DW group as he did not report for the examinations. RESULTS As far as safety parameters are concerned, no differences were observed between groups in two-year follow-up (p > 0.05). However, in the DW group the endothelial cell loss was higher (p < 0.05). Total PCO score differences were observed in both groups between the areas (p < 0.05). In the CAPS area, both Total PCO score and PCO area were decreased in the DW group (p < 0.05). PCO was also lower within 3 mm zone in the DW group (p < 0.05). CONCLUSIONS SCI is a safe procedure and the endothelial cells loss can be associated with the Perfect Capsule™ device (Milvella) in the anterior chamber insertion. DW irrigated for 3' reduces PCO in long-term follow-up.
Collapse
Affiliation(s)
- Marek Rękas
- Ophthalmology Department, Military Institute of Medicine, Warsaw, Poland.
| | | | | |
Collapse
|
22
|
Posterior capsule opacification following 20- and 23-gauge phacovitrectomy (posterior capsule opacification following phacovitrectomy). Eye (Lond) 2012; 26:1459-64. [PMID: 23018664 DOI: 10.1038/eye.2012.193] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To compare the development of posterior capsule opacification (PCO) for idiopathic epi-retinal membrane cases between 20- and 23-gauge phacovitrectomy. METHODS Cataract surgery of phacoemulsification with the SA60AT implantation and 20- or 23-gauge vitrectomy was performed for 20 patients in both groups. Cataract surgery alone was performed for 50 patients as the control. The PCO density values were measured using Scheimpflug video photography at 1 week, 1, 3, 6, 12, 18, and 24 months after surgery. The number of eyes that required Nd:YAG laser capsulotomy was also examined. RESULTS The mean PCO value in the 20-gauge phacovitrectomy group increased significantly with time (P<0.001), whereas those in the 23-gauge phacovitrectomy group and the cataract surgery group did not show any significant change. Furthermore, the PCO value in the 20-gauge phacovitrectomy group was significantly greater than that in the 23-gauge phacovitrectomy group at 6, 12, 18 (P<0.05), and 24 months (P<0.01) after surgery. The PCO value in the 23-gauge phacovitrectomy group was significantly greater than that in the cataract surgery group 24 months after surgery (P<0.05). The rate of capsulotomy in the 20-gauge phacovitrectomy group was significantly higher than that in the cataract surgery group (P=0.007), whereas there was no significant difference between the 23-gauge phacovitrectomy group and the cataract surgery group. CONCLUSION PCO rate in eyes with the 23-gauge phacovitrectomy was lower than in those with the 20-gauge phacovitrectomy, and PCO rate even in the 23-gauge phacovitrectomy was higher than in those with cataract surgery.
Collapse
|
23
|
Corneal perforation during Nd:YAG laser capsulotomy: a case report. Int Ophthalmol 2012; 33:99-101. [DOI: 10.1007/s10792-012-9639-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2012] [Accepted: 09/15/2012] [Indexed: 11/25/2022]
|
24
|
Hayashi K, Hirata A, Yoshida M, Yoshimura K, Hayashi H. Long-term effect of surface light scattering and glistenings of intraocular lenses on visual function. Am J Ophthalmol 2012; 154:240-251.e2. [PMID: 22633349 DOI: 10.1016/j.ajo.2012.03.011] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2012] [Revised: 03/08/2012] [Accepted: 03/08/2012] [Indexed: 10/28/2022]
Abstract
PURPOSE To investigate the long-term effect of surface light scattering and glistenings of various intraocular lenses (IOLs) on visual function and optical aberrations after cataract surgery. DESIGN Case-control study. METHODS Thirty-five eyes that underwent implantation of a hydrophobic acrylic, silicone, or polymethyl methacrylate (PMMA) IOL more than 10 years ago were recruited. The scattering light intensity of the surface and internal matrix of the optic was measured using Scheimpflug photography. Visual acuity (VA) was measured using VA charts, and contrast VA and that with glare (glare VA) were examined using a contrast sensitivity tester. Ocular higher-order aberrations (HOAs) were measured using a Hartmann-Shack aberrometer. RESULTS Mean scattering light intensity of the surface and internal matrix of the optic was significantly higher in the acrylic group than in the silicone and PMMA groups (P < .0001). Mean uncorrected VA, photopic and mesopic contrast VA and glare VA, and HOAs did not differ significantly among groups, although mean corrected VA in the acrylic group was significantly better than that in the other groups (P = .0023). Scattering light intensity of the surface and internal matrix did not correlate with VA, contrast VA, or glare VA, and did not correlate with ocular and internal optic HOAs in the acrylic group. CONCLUSIONS At more than 10 years postoperatively, visual function, including contrast sensitivity, and ocular HOAs were comparable among eyes that received acrylic, silicone, and PMMA IOLs. Surface scattering and glistenings with the acrylic IOLs were not significantly correlated with visual function and optical aberrations.
Collapse
|
25
|
Vasavada AR, Raj SM, Shah A, Shah G, Vasavada V, Vasavada V. Comparison of posterior capsule opacification with hydrophobic acrylic and hydrophilic acrylic intraocular lenses. J Cataract Refract Surg 2011; 37:1050-9. [PMID: 21596247 DOI: 10.1016/j.jcrs.2010.12.060] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2010] [Revised: 12/11/2010] [Accepted: 12/18/2010] [Indexed: 12/21/2022]
Abstract
PURPOSE To compare posterior capsule opacification (PCO) 3 years postoperatively in contralateral eyes with a single-piece hydrophobic acrylic and 1 of 2 single-piece hydrophilic acrylic intraocular lenses (IOLs) with different configurations. SETTING Iladevi Cataract and IOL Research Institute, Ahmedabad, India. DESIGN Prospective randomized clinical trial. METHODS A hydrophobic Acrysof (hydrophobic group) or a hydrophilic C-flex (hydrophilic group C) or Akreos Adapt IOL (hydrophilic group A) was randomized for implantation in the fellow eye or vice versa of each patient. The Evaluation of Posterior Capsule Opacification (EPCO) area, EPCO score, and neodymium:YAG (Nd:YAG) capsulotomy rates were compared using digital photographs. RESULTS The study enrolled 68 patients. Although there was no significant difference at 1 month, the median EPCO score was statistically significantly lower in the hydrophobic group than in hydrophilic group C (P = .00) and hydrophilic group A (P = .000) at 3 years. There were no significant differences in the median EPCO area at 1 month; however, the area was statistically significantly less in the hydrophobic group than in hydrophilic group C and hydrophilic group A at 3 years (both P = .000). Four (12.9%) of 31 eyes in hydrophilic group C and 5 (16%) of 31 eyes in hydrophilic group A required an Nd:YAG capsulotomy; no eye in the hydrophobic group required a capsulotomy (P = .04 and P = .02, respectively). CONCLUSION Posterior capsule opacification was significantly less with the Acrysof hydrophobic acrylic IOL at 3 years. FINANCIAL DISCLOSURE No author has a financial or proprietary interest in any material or method mentioned.
Collapse
Affiliation(s)
- Abhay R Vasavada
- Iladevi Cataract & IOL Research Centre, Raghudeep Eye Clinic, Memnagar, Ahmedabad, India
| | | | | | | | | | | |
Collapse
|
26
|
Choi S, Lee SJ, Shin JH, Cheong Y, Lee HJ, Paek JH, Kim JS, Jin KH, Park HK. Ultrastructural investigation of intact orbital implant surfaces using atomic force microscopy. SCANNING 2011; 33:211-221. [PMID: 21538394 DOI: 10.1002/sca.20235] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2011] [Accepted: 04/05/2011] [Indexed: 05/30/2023]
Abstract
This study examined the surface nanostructures of three orbital implants: nonporous poly(methyl methacrylate) (PMMA), porous aluminum oxide and porous polyethylene. The morphological characteristics of the orbital implants surfaces were observed by atomic force microscopy (AFM). The AFM topography, phase shift and deflection images of the intact implant samples were obtained. The surface of the nonporous PMMA implant showed severe scratches and debris. The surface of the aluminum oxide implant showed a porous structure with varying densities and sizes. The PMMA implant showed nodule nanostructures, 215.56 ± 52.34 nm in size, and the aluminum oxide implant showed crystal structures, 730.22 ± 341.02 nm in size. The nonporous PMMA implant showed the lowest roughness compared with other implant biomaterials, followed by the porous aluminum oxide implant. The porous polyethylene implant showed the highest roughness and severe surface irregularities. Overall, the surface roughness of orbital implants might be associated with the rate of complications and cell adhesion.
Collapse
Affiliation(s)
- Samjin Choi
- Department of Biomedical Engineering & Healthcare Industry Research Institute, College of Medicine, Kyung Hee University, Seoul, Republic of Korea
| | | | | | | | | | | | | | | | | |
Collapse
|
27
|
Hydrophobic versus double-square-edged hydrophilic foldable acrylic intraocular lens: Effect on posterior capsule opacification. J Cataract Refract Surg 2011; 37:1060-8. [DOI: 10.1016/j.jcrs.2010.12.059] [Citation(s) in RCA: 31] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2010] [Revised: 12/18/2010] [Accepted: 12/29/2010] [Indexed: 11/20/2022]
|
28
|
Abstract
BACKGROUND Posterior capsule opacification (PCO) remains the most common long-term complication after cataract surgery. It can be treated by Nd:YAG laser capsulotomy, however this may lead to other complications and laser treatment is not available in large parts of the developing world. Therefore, many studies try to find factors influencing the development of PCO. OBJECTIVES To summarise the effects of different interventions to inhibit PCO. These include modifications of surgical technique and intraocular lens (IOL) design, implantation of additional devices and pharmacological interventions. SEARCH STRATEGY We searched CENTRAL, MEDLINE, EMBASE, LILACS in March 2009 and reference lists of identified trial reports. SELECTION CRITERIA We included only prospective, randomised and controlled trials with a follow-up time of at least 12 months. Interventions included modifications in surgical technique explicitly to inhibit PCO, modifications in IOL design (material and geometry), implantation of additional devices and pharmacological therapy compared to each other, placebo or standard treatment. DATA COLLECTION AND ANALYSIS We extracted data and entered it into RevMan. We compared visual acuity data, PCO scores and YAG capsulotomy rates and performed a meta-analysis when possible. MAIN RESULTS Sixty six studies were included in the review. The review was divided into three parts. 1. Influence of IOL optic material on the development of PCO. There was no significant difference in PCO development between the different IOL materials (PMMA, hydrogel, hydrophobic acrylic, silicone) although hydrogel IOLs tend to have higher PCO scores and silicone IOLs lower PCO scores than the other materials. 2. Influence of IOL optic design on the development of PCO. There was a significantly lower PCO score (-8.65 (-10.72 to -6.59), scale 0 to 100) and YAG rate (0.19 (0.11 to 0.35)) in sharp edged than in round edged IOLs, however not between 1-piece and 3-piece IOLs. 3. Influence of surgical technique and drugs on the development of PCO. There was no significant difference between different types of intraoperative/postoperative anti-inflammatory treatment except for treatment with an immunotoxin (MDX-A) which led to a significantly lower PCO rate. AUTHORS' CONCLUSIONS Due to the highly significant difference between round and sharp edged IOL optics, IOLs with sharp (posterior) optic edges should be preferred. There is no clear difference between optic materials. The choice of postoperative anti-inflammatory treatment does not seem to influence PCO development.
Collapse
Affiliation(s)
- Oliver Findl
- Hanusch HospitalDepartment of OphthalmologyHeinrich‐Collin‐Strasse 30ViennaAustriaA‐1140
| | - Wolf Buehl
- Medical University of ViennaDepartment of OphthalmologyWähringer Gürtel 18‐20ViennaAustria1090
| | - Peter Bauer
- Medical University of ViennaInstitute of Medical StatisticsSpitalgasse23ViennaAustriaA‐1090
| | - Thomas Sycha
- Medical University of ViennaDepartment of NeurologyWähringer Gürtel 18‐20ViennaAustriaA‐1090
| | | |
Collapse
|
29
|
Rönbeck M, Zetterström C, Wejde G, Kugelberg M. Comparison of posterior capsule opacification development with 3 intraocular lens types: five-year prospective study. J Cataract Refract Surg 2010; 35:1935-40. [PMID: 19878826 DOI: 10.1016/j.jcrs.2009.05.048] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2009] [Revised: 05/07/2009] [Accepted: 05/08/2009] [Indexed: 11/26/2022]
Abstract
PURPOSE To compare the effects of hydrophobic acrylic, silicone, and heparin-surface-modified poly(methyl methacrylate) (HSM PMMA) intraocular lenses (IOLs) on posterior capsule opacification (PCO). METHODS In this 5-year prospective study, the same surgeon performed standard phacoemulsification in patients who were randomized to implantation of a round-edged HSM PMMA IOL (809C), a round-edged silicone IOL (SI-40NB), or a sharp-edged hydrophobic acrylic IOL (AcrySof MA60BM). The neodymium:YAG capsulotomy rate was recorded. To evaluate PCO and the position of the anterior capsulorhexis, retroillumination digital photographs were taken 5 years postoperatively and analyzed using the POCOman computer-analysis system. RESULTS After 5 years, there was no significant difference in the fraction or severity of PCO between the silicone IOLs and acrylic IOLs (both P =1.0). The silicone IOL group had a significantly higher capsulotomy rate (29%) than the acrylic IOL group (8%) (P=.0068). The HSM PMMA IOL group had a significantly higher PCO fraction, severity, and capsulotomy rate (54%) than the silicone and acrylic groups. In all eyes, the fraction (P=.0076) and severity (P=.0081) of PCO were statistically significantly higher when the anterior capsulorhexis was partly decentered than when it was completely on the optic; within each IOL group, there was no significant difference. CONCLUSION After 5 years, there was no significant difference in the semiquantitative evaluation of PCO between the sharp-edged acrylic IOL and round-edged silicone IOL. Eyes with the HSM PMMA IOL had more PCO than eyes with the other IOLs.
Collapse
|
30
|
Auffarth GU, Brezin A, Caporossi A, Lafuma A, Mendicute J, Berdeaux G, Smith AF. Comparison of Nd : YAG capsulotomy rates following phacoemulsification with implantation of PMMA, silicone, or acrylic intra-ocular lenses in four European countries. Ophthalmic Epidemiol 2009; 11:319-29. [PMID: 15512993 DOI: 10.1080/09286580490515116] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
PURPOSE The aim of this study was to compare the incidence of Nd : YAG laser capsulotomy after cataract surgery according to the type of intra-ocular lens material (PMMA, silicone, hydrophilic acrylic, hydrophobic acrylic) implanted in four European countries (France, Italy, Germany, Spain). DESIGN A retrospective record review. PARTICIPANTS A review of 1525 patients (first operated eye), aged 50 to 80 years, operated on for cataract in 1996 or 1997 in 16 surgical centers (4 per country). METHODS The study employed a retrospective cohort design. Charts were reviewed to collect information during at least a three-year period following cataract surgery to identify patients who underwent Nd : YAG laser capsulotomy postoperatively. MAIN OUTCOME MEASURES Data on the type of intra-ocular lens implanted was extracted from the patient notes, as was the date and outcome of the Nd : YAG laser intervention. Kaplan-Meier survival curve analysis with the time to Nd : YAG laser was performed on the data. RESULTS A total of 1525 patients (first operated eye) were available for the study (n = 294 for hydrophilic acrylic, n = 384 for PMMA, n = 421 for hydrophobic acrylic, n = 426 for silicone). There was a highly statistically significant difference between the IOL groups for the incidence of posterior capsule opacification (p < 0.001) and for Nd : YAG laser treatment (p < 0.001). The mean delay of Nd : YAG laser treatment from the date of cataract operation was 2.48 years (+/-1.70, ranging from 0 to 5.88 years). The rate of Nd : YAG laser capsulotomy over the follow-up period was lowest in the hydrophobic acrylic group (7.1%), followed by silicone (16.2%), PMMA (19.3%) and hydrophilic acrylic (31.1%), respectively. CONCLUSIONS A low incidence of posterior capsular opacification (PCO) and Nd : YAG laser treatment was detected in hydrophobic acrylic IOLs in comparison to three other types of IOLs implanted in a large cohort of persons with age-related cataract. Choice of IOL type may reduce the need for Nd : YAG laser treatment, although further research on the reasons for this is needed.
Collapse
Affiliation(s)
- Gerd U Auffarth
- Department of Ophthalmology Ruprecht-Karls-University Heidelberg Germany
| | | | | | | | | | | | | |
Collapse
|
31
|
Wormstone IM, Wang L, Liu CSC. Posterior capsule opacification. Exp Eye Res 2008; 88:257-69. [PMID: 19013456 DOI: 10.1016/j.exer.2008.10.016] [Citation(s) in RCA: 197] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2008] [Revised: 10/13/2008] [Accepted: 10/14/2008] [Indexed: 11/18/2022]
Abstract
Posterior Capsule Opacification (PCO) is the most common complication of cataract surgery. At present the only means of treating cataract is by surgical intervention, and this initially restores high visual quality. Unfortunately, PCO develops in a significant proportion of patients to such an extent that a secondary loss of vision occurs. A modern cataract operation generates a capsular bag, which comprises a proportion of the anterior and the entire posterior capsule. The bag remains in situ, partitions the aqueous and vitreous humours, and in the majority of cases, houses an intraocular lens. The production of a capsular bag following surgery permits a free passage of light along the visual axis through the transparent intraocular lens and thin acellular posterior capsule. However, on the remaining anterior capsule, lens epithelial cells stubbornly reside despite enduring the rigours of surgical trauma. This resilient group of cells then begin to re-colonise the denuded regions of the anterior capsule, encroach onto the intraocular lens surface, occupy regions of the outer anterior capsule and most importantly of all begin to colonise the previously cell-free posterior capsule. Cells continue to divide, begin to cover the posterior capsule and can ultimately encroach on the visual axis resulting in changes to the matrix and cell organization that can give rise to light scatter. This review will describe the biological mechanisms driving PCO progression and discuss the influence of IOL design, surgical techniques and putative drug therapies in regulating the rate and severity of PCO.
Collapse
Affiliation(s)
- I Michael Wormstone
- School of Biological Sciences, University of East Anglia, Norwich, United Kingdom.
| | | | | |
Collapse
|
32
|
Effect of a capsular tension ring on prevention of intraocular lens decentration and tilt and on anterior capsule contraction after cataract surgery. Jpn J Ophthalmol 2008; 52:363-367. [DOI: 10.1007/s10384-008-0570-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2008] [Accepted: 04/23/2008] [Indexed: 12/18/2022]
|
33
|
Kohnen T, Fabian E, Gerl R, Hunold W, Hütz W, Strobel J, Hoyer H, Mester U. Optic Edge Design as Long-term Factor for Posterior Capsular Opacification Rates. Ophthalmology 2008; 115:1308-14, 1314.e1-3. [DOI: 10.1016/j.ophtha.2008.01.002] [Citation(s) in RCA: 63] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2006] [Revised: 12/20/2007] [Accepted: 01/02/2008] [Indexed: 10/22/2022] Open
|
34
|
Li N, Chen X, Zhang J, Zhou Y, Yao X, Du L, Wei M, Liu Y. Effect of AcrySof versus Silicone or Polymethyl Methacrylate Intraocular Lens on Posterior Capsule Opacification. Ophthalmology 2008; 115:830-8. [PMID: 17964657 DOI: 10.1016/j.ophtha.2007.06.037] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2006] [Revised: 06/21/2007] [Accepted: 06/26/2007] [Indexed: 10/22/2022] Open
|
35
|
Moreno-Montañés J, Alvarez A, Bes-Rastrollo M, García-Layana A. Optical coherence tomography evaluation of posterior capsule opacification related to intraocular lens design. J Cataract Refract Surg 2008; 34:643-50. [PMID: 18361988 DOI: 10.1016/j.jcrs.2007.11.035] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2007] [Accepted: 11/19/2007] [Indexed: 11/30/2022]
Abstract
PURPOSE To evaluate posterior capsule opacification (PCO) and the impact of different intraocular lens (IOL) models on PCO characteristics using optical coherence tomography (OCT). METHODS Eighty-three eyes with PCO (fibrosis or pearl type) and 32 pseudophakic eyes without PCO were included. Horizontal 3.0 mm long OCT scans of the posterior capsule were obtained. Measurements and means of the peak posterior capsule intensity (PCI) and posterior capsule thickness (PCT) (distance between 2 spikes at posterior capsule) at 3 scan points were recorded. The PCI and PCT were compared with best corrected visual acuity (BCVA) and IOL data. RESULTS The PCT was high for IOLs with a rounded edge (P = .001) and with poly(methyl methacrylate) (PMMA) IOLs (P<.001). If the IOL optic was concave-convex, the PCT was higher than if the optic was biconvex (P = .001). The PCT of hydrophilic acrylic IOLs was higher than of hydrophobic acrylic IOLs (P = .04). Multivariate analysis of PCT showed that PMMA was the only factor statistically associated with PCT (P = .02). The worse logMAR BCVA correlated significantly with a higher PCT value (P<.001) but not with PCI (P = .42). An IOL size of 12.5 mm was related to fibrosis-type PCO (odds ratio, 3.14; P = .04). CONCLUSIONS The PCT was most affected by IOL characteristics. Poly(methyl methacrylate) IOLs and IOLs with rounded edges were associated with higher PCT. Hydrophilic acrylic IOLs were associated with greater PCT than hydrophobic IOLs. Posterior capsule thickness was a factor in decreased BCVA.
Collapse
Affiliation(s)
- Javier Moreno-Montañés
- Department of Ophthalmology, Clínica Universitaria, Facultad de Medicina, Universidad de Navarra, Pamplona, Spain
| | | | | | | |
Collapse
|
36
|
Visualization of the Retinal Image in an Eye Model With Spherical and Aspheric, Diffractive, and Refractive Multifocal Intraocular Lenses. J Refract Surg 2008; 24:223-32. [DOI: 10.3928/1081597x-20080301-03] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
37
|
Zhang H, Duncan G, Wang L, Liu P, Cui H, Reddan JR, Yang BF, Wormstone IM. Arsenic trioxide initiates ER stress responses, perturbs calcium signalling and promotes apoptosis in human lens epithelial cells. Exp Eye Res 2007; 85:825-35. [DOI: 10.1016/j.exer.2007.08.018] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2007] [Revised: 08/08/2007] [Accepted: 08/10/2007] [Indexed: 11/25/2022]
|
38
|
Effect of square-edged intraocular lenses on neodymium:YAG laser capsulotomy rates in the United States. J Cataract Refract Surg 2007; 33:1899-906. [DOI: 10.1016/j.jcrs.2007.06.056] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2007] [Accepted: 06/26/2007] [Indexed: 11/15/2022]
|
39
|
Hayashi K, Hayashi H. Influence on posterior capsule opacification and visual function of intraocular lens optic material. Am J Ophthalmol 2007; 144:195-202. [PMID: 17553447 DOI: 10.1016/j.ajo.2007.04.044] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2007] [Revised: 04/17/2007] [Accepted: 04/19/2007] [Indexed: 10/23/2022]
Abstract
PURPOSE To examine the influence of optic material on posterior capsule opacification (PCO) by comparing PCO and visual functions between eyes with an acrylic intraocular lens (IOLs) and those with a silicone IOL of the same optic design and with the same haptics. DESIGN Randomized clinical trial. METHODS One hundred patients scheduled for phacoemulsification surgery underwent implantation of an acrylic IOL (AMO Sensar; AR40e) in one eye and implantation of a silicone IOL (ClariFlex) of the same optic design and loops in the fellow eye. Eighty-nine patients (89%) remained for analysis. The PCO value was measured using the Scheimpflug videophotography system at one, three, six, 12, 18, 24, 30, and 36 months postoperatively. The incidence of eyes that required a neodymium:yttrium-aluminum-garnet (Nd:YAG) laser capsulotomy was examined; visual acuity and contrast sensitivity with and without a glare source were also evaluated. RESULTS The mean PCO value did not increase significantly during follow-up in either the acrylic or silicone IOL group. When comparing the groups, no statistically significant difference was found in the PCO or in the incidence of Nd:YAG capsulotomy, although both tended to be slightly better in the silicone group than in the acrylic group. There was also no significant difference between the groups in visual acuity or in photopic and mesopic contrast sensitivity with or without glare. CONCLUSIONS When acrylic and silicone IOLs are of the same optic design and with the same haptics, the optic material does not influence the development of PCO enough to impair visual function.
Collapse
|
40
|
Abstract
BACKGROUND Posterior capsule opacification (PCO) remains the most common long-term complication after cataract surgery. It can be treated by Nd:YAG laser capsulotomy, however, this may lead to other complications and laser treatment is not available in large parts of the developing world. Therefore, many studies try to find factors influencing the development of PCO. OBJECTIVES To summarise the effects of different interventions to inhibit PCO. These include modifications of surgical technique and intraocular lens (IOL) design, implantation of additional devices and pharmacological interventions. SEARCH STRATEGY We searched CENTRAL, MEDLINE, EMBASE, LILACS in January 2007 and reference lists of identified trial reports. SELECTION CRITERIA We included only prospective, randomised and controlled trials with a follow-up time of at least 12 months. Interventions included modifications in surgical technique explicitly to inhibit PCO, modifications in IOL design (material and geometry), implantation of additional devices, and pharmacological therapy, compared to each other, placebo or standard treatment. DATA COLLECTION AND ANALYSIS Data were extracted and entered into Review Manager. Visual acuity data, PCO score and YAG capsulotomy rates were compared and a meta-analysis was performed when possible. MAIN RESULTS Fifty three studies were included in the review. The review was divided into three parts. (1) Influence of IOL optic material on the development of PCO. Compared to other materials, the meta-analysis of the included studies showed a significantly higher PCO score (overall effect: 12.39 (95% confidence interval: 9.82 to 14.95), scale 0 to 100) and YAG rate (odds ratio: 8.37 (3.74 to 20.36)) only in hydrogel IOLs. (2) Influence of IOL optic design on the development of PCO. There was a significantly lower PCO score (-8.65 (-10.72 to -6.59), scale 0 to 100) and YAG rate (0.19 (0.11 to 0.35)) in sharp edged than in round edged IOLs, however, not between 1-piece and 3-piece IOLs. (3) Influence of surgical technique and drugs on the development of PCO. There was no significant difference between different types of intra-/postoperative anti-inflammatory treatment except for treatment with an immunotoxin (MDX-A) leading to a significantly lower PCO rate. AUTHORS' CONCLUSIONS Due to the highly significant difference between round and sharp edge IOL optics, IOLs with sharp (posterior) optic edges should be preferred. There is no clear difference between optic materials, except for hydrogel IOLs, that showed more PCO than the other materials. The choice of postoperative anti-inflammatory treatment does not seem to influence PCO development.
Collapse
Affiliation(s)
- O Findl
- Medical University of Vienna, Department of Ophthalmology, Allgemeines Krankenhaus Wien, Währinger Gürtel 18-20, Vienna, Austria, A-1090.
| | | | | | | |
Collapse
|
41
|
Cheng JW, Wei RL, Cai JP, Xi GL, Zhu H, Li Y, Ma XY. Efficacy of different intraocular lens materials and optic edge designs in preventing posterior capsular opacification: a meta-analysis. Am J Ophthalmol 2007; 143:428-36. [PMID: 17224119 DOI: 10.1016/j.ajo.2006.11.045] [Citation(s) in RCA: 75] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2006] [Revised: 11/16/2006] [Accepted: 11/19/2006] [Indexed: 11/27/2022]
Abstract
PURPOSE To evaluate the efficacy of different intraocular lens (IOL) materials and optic edge designs in preventing posterior capsular opacification (PCO). DESIGN Systematic review and meta-analysis. METHODS Pertinent studies were selected through an electronic search of the Cochrane Library, MEDLINE, and Embase. The randomized controlled trials meeting the predefined criteria were reviewed systematically by meta-analysis. The treatment effects were measured as risk difference, and the pooled estimates were computed according to a random effect model. RESULTS In total, 23 randomized controlled trials were included in the present meta-analysis. The pooled risk differences of Nd:YAG laser capsulotomy rates were -24% (95% confidence interval [CI], -29% to -20%) comparing acrylic with polymethylmethacrylate (PMMA) lenses; -9% (95% CI, -17% to -1%) comparing silicone with PMMA lenses; 14% (95% CI, -8% to 36%) comparing hydrogel with PMMA lenses; 4% (95% CI, -2% to 10%) comparing silicone with acrylic lenses; 19% (95% CI, 8% to 30%) comparing hydrogel with acrylic lenses; and 28% (95% CI, 10% to 46%) comparing hydrogel with silicone lenses. The pooled risk differences of PCO rates were -39% (95% CI, -47% to -31%) comparing acrylic with PMMA lenses; -14% (95% CI, -29% to 0%) comparing silicone with acrylic lenses; 56% (95% CI, 36% to 75%) comparing hydrogel with acrylic lenses; and 48% (95% CI, 31% to 64%) comparing hydrogel with silicone lenses. When comparing sharp with rounded-edge designs, pooled risk differences of capsulotomy rates were -47% (95% CI, -77% to -17%) in PMMA lenses, -22% (95% CI, -47% to 2%) in acrylic lenses, and -9% (95% CI, -17% to 0%) in silicone lenses; pooled risk differences of PCO rates were -28% (95% CI, -50% to -7%) in acrylic lenses and -37% (95% CI, -46% to -27%) in silicone lenses. CONCLUSIONS The rates of PCO and Nd:YAG laser capsulotomy may be influenced by different IOL biomaterials and optic edge designs. The lenses made by acrylic and silicone and those with sharp optic edges are superior in lowering the rates of PCO and laser capsulotomy.
Collapse
Affiliation(s)
- Jin-Wei Cheng
- Department of Ophthalmology, Changzheng Hospital, Second Military Medical University, Shanghai, China
| | | | | | | | | | | | | |
Collapse
|
42
|
Beale AB, Salmon J, Michau TM, Gilger BC. Effect of ophthalmic Nd:YAG laser energy on intraocular lenses after posterior capsulotomy in normal dog eyes. Vet Ophthalmol 2006; 9:335-40. [PMID: 16939462 DOI: 10.1111/j.1463-5224.2006.00473.x] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Abstract
OBJECTIVE To determine Nd:YAG laser energy requirements for posterior capsulotomy and intraocular lens (IOL) damage threshold for foldable acrylic IOLs as compared to traditional polymethylmethacrylate (PMMA). MATERIALS AND PROCEDURES: Four groups of five-six fresh canine cadaver eyes were used in this study. The groups included (1) unaltered eyes (2) aphakic eyes (3) eyes implanted with PMMA IOLs, and (4) eyes implanted with acrylic IOLs. Laser energy was delivered to the posterior capsule in grid fashion for 10 sites each of five levels of laser energy ranging from 0.5 mJ to 9 mJ. Number of successful capsulotomy sites was recorded based on slit-lamp observation. Sites of IOL damage were evaluated using scanning electron microscopy (SEM). Statistical analysis of number of capsulotomies and IOL defects per laser energy level was conducted among and between groups using anova with Tukey's HSD test. RESULTS When comparing groups (a) including all energy levels (n = 25) and (b) by specific energy levels (n = 5), there was no significant difference (P < 0.05) in number of successful capsulotomy sites between IOL types. The 50% incidence threshold for successful capsulotomy was 2.74 mJ for acrylic IOLs and 2.64 mJ for PMMA IOLs. Energy-dependent damage to both types of IOL was detected for medium, high-medium, and high laser energy. Calculated 50% damage threshold was 4.9 mJ for acrylic IOL and 5.7 mJ for PMMA IOL. Damage to the IOL varied subjectively between IOL type, but there was no significant difference in number of defects caused, with the exception of high-medium energy. CONCLUSIONS Both posterior lens capsules and IOLs were disrupted in an energy-dependent manner with minimal difference in number of capsulotomy sites or damage to the IOL between acrylic and PMMA IOLs. A therapeutic margin between capsulotomy threshold (2.6-2.7 mJ) and IOL damage threshold (4.9-5.7 mJ) was determined to reliably achieve capsulotomies with minimal IOL damage for both acrylic and PMMA IOLs in normal canine cadaver eyes.
Collapse
Affiliation(s)
- A Brady Beale
- Department of Clinical Sciences, College of Veterinary Medicine, North Carolina State University, 4700 Hillsborough St., Raleigh, NC, USA
| | | | | | | |
Collapse
|
43
|
Bras ID, Colitz CMH, Saville WJA, Gemensky-Metzler AJ, Wilkie DA. Posterior capsular opacification in diabetic and nondiabetic canine patients following cataract surgery. Vet Ophthalmol 2006; 9:317-27. [PMID: 16939460 DOI: 10.1111/j.1463-5224.2006.00458.x] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Posterior capsular opacification (PCO) is the most common postoperative complication of contemporary cataract surgery. Limited information is available regarding PCO formation and factors that influence PCO development in the dog. Two hundred sixty-five eyes (144 from diabetic dogs and 121 from dogs with breed-related cataracts) were prospectively evaluated for PCO formation for up to 12 months postoperatively. The mean age of all dogs in the study was 7.77 years and diabetic dogs were significantly older than dogs with breed-related cataracts. There were 73 males (61 neutered, 12 intact) and 74 females (70 neutered, 4 intact) in the study. Statistical analysis was performed based on age, breed/size, gender, stage of cataract at the time of surgery, PCO score at each time point, breed-related vs. diabetic cataract, right eyes compared to left eyes, and presence/absence of uveitis. Age and gender did not significantly influence PCO formation. Small and medium-sized breeds developed significantly more PCO in comparison to the large/giant breeds at 2 weeks and 2-4 months postoperatively, but the differences were not significant at later time points. There was an overall significant increase in PCO formation in eyes with early immature cataracts when compared to other stages of cataract up to 4 months postoperatively but not at later time points. There were no statistical differences in PCO score at 6 months or at 1 year postoperatively in eyes with breed-related and diabetic cataracts. Right eyes did not differ from left eyes in PCO score. PCO score significantly increased over time in breed-related and diabetic groups and in the overall population. No difference was found in the degree of PCO formation in eyes with inflammation prior to or after surgery compared with those without inflammation. In summary, age, gender, presence of inflammation, and cause of cataract (breed-related vs. diabetes mellitus) do not influence the development of PCO in canine cataract dogs. Small and medium-sized breeds develop significant PCO earlier than larger breeds. It is important to note that all eyes from all dogs in this study developed PCO in a time dependent manner.
Collapse
Affiliation(s)
- I Dineli Bras
- Department of Veterinary Clinical Sciences, The Ohio State University College of Veterinary Medicine, Columbus, OH 43210, USA
| | | | | | | | | |
Collapse
|
44
|
Matsushima H, Iwamoto H, Mukai K, Obara Y. Active oxygen processing for acrylic intraocular lenses to prevent posterior capsule opacification. J Cataract Refract Surg 2006; 32:1035-40. [PMID: 16814067 DOI: 10.1016/j.jcrs.2006.02.042] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2005] [Accepted: 11/21/2005] [Indexed: 11/23/2022]
Abstract
PURPOSE To evaluate active oxygen processing on the surface of acrylic intraocular lenses (IOLs) to prevent secondary posterior capsule opacification (PCO). SETTING Department of Ophthalmology, Dokkyo Medical University School of Medicine, Mibu City, Tochigi, Japan. METHODS Acrylic IOLs were prepared, and ultraviolet (UV)/ozone (UV/O3) or argon plasma was irradiated to the surface of the IOLs. Elemental analysis (electron spectroscopy for chemical analysis [ESCA]) of the IOL surfaces was performed to confirm surface modification. Changes produced by UV/O3 or argon plasma treatment were examined for fibronectin and lens epithelial cell (LEC) adhesion. To evaluate the PCO prevention by treated IOLs, 8-week-old albino rabbits were used. The rabbit eyes randomly had phacoemulcification and implantation of 3 different IOLs: the UV/O3-treated IOLs, argon plasma-treated IOLs, and the control IOLs. After 2 weeks, the rabbits were killed and their globes were dissected and fixed using formaldehyde 10%. The PCO was observed using light microscopy (DX51, ORIMPUS) after hematoxylin and eosin staining. RESULTS Comparison of IOL surface composition by ESCA showed an increase in nitrogen content and hydroxyl substitute and carboxyl substitute groups on surfaces of treated IOLs. The fibronectin adhesion and the LEC adhesion on the UV/O3-treated and argon plasma-treated samples were increased. In the untreated group, there was statistically significant inhibition of PCO formation in the UV/O3-treated and argon plasma-treated groups. CONCLUSION Active oxygen processing and argon plasma irradiation on the surface of IOLs was effective in preventing secondary PCO after cataract surgery.
Collapse
Affiliation(s)
- Hiroyuki Matsushima
- Department of Ophthalmology, Dokkyo Medical University School of Medicine, Tochigi, Japan
| | | | | | | |
Collapse
|
45
|
Lombardo M, De Santo MP, Lombardo G, Barberi R, Serrao S. Analysis of intraocular lens surface properties with atomic force microscopy. J Cataract Refract Surg 2006; 32:1378-84. [PMID: 16863979 DOI: 10.1016/j.jcrs.2006.02.068] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2005] [Accepted: 02/14/2006] [Indexed: 11/24/2022]
Abstract
PURPOSE To analyze the surface optics of 4 currently available intraocular lenses (IOLs) with atomic force microscopy. SETTING Licryl Laboratory, University of Calabria, Rende, Italy. METHODS The surface roughness and topography of poly(methyl methacrylate) (PMMA), silicone, hydrophobic, and hydrophilic acrylic IOLs were evaluated with atomic force microscopy in contact mode. The analysis was performed in a liquid environment using cantilevers with a 0.01 Newtonw/meter nominal elastic constant. Measurements were made over areas of 10 microm2 on different locations of the posterior optic surface of the IOL. RESULTS Atomic force microscopy permitted high-resolution imaging of IOL optic surface characteristics. Surface topography showed different features with respect to the lens biomaterial. The root-mean-square roughness of the IOL optic surface was significantly different between lenses of various materials (P < .001). The hydrophobic acrylic and silicone IOLs had the lowest mean surface roughness, 3.8 nm +/- 0.2 (SD) and 4.0 +/- 0.5 nm, respectively, and the 2 PMMA IOLs had the highest mean surface roughness, 6.6 +/- 0.3 nm and 7.0 +/- 0.6 nm. CONCLUSIONS Atomic force microscopy was effective and accurate in analyzing IOL optics. The surface topography of IOLs may vary with different manufacturing processes.
Collapse
Affiliation(s)
- Marco Lombardo
- Department of Experimental and Clinical Medicine, University Magna Graecia, Catanzaro and Vision Engineering, Reggio, Calabria, Italy.
| | | | | | | | | |
Collapse
|
46
|
Hayashi K, Yoshida M, Hayashi H. Comparison of posterior capsule opacification between fellow eyes with two types of acrylic intraocular lens. Eye (Lond) 2006; 22:35-41. [PMID: 16823457 DOI: 10.1038/sj.eye.6702496] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
PURPOSE To compare the degree of posterior capsule opacification (PCO) and visual function between fellow eyes that received two different types of hydrophobic acrylic intraocular lenses (IOLs). METHODS Forty-five patients underwent bilateral phacoemulsification and implantation of an Alcon AcrySof IOL (MA60AC) in one eye and an AMO Sensar IOL (AR40e) in the fellow eye. The PCO density value was measured using the Scheimpflug videophotography system at 1, 6, 12, and 24 months after surgery. The incidence of eyes that required a neodymium:YAG (Nd:YAG) laser capsulotomy, visual acuity, and contrast sensitivity with and without a glare source were also examined. RESULTS The mean PCO value did not show a significant increase in either the AcrySof MA60AC or Sensar AR40e IOL groups, and was similar between the two groups throughout the 24-month follow-up period. The incidence of Nd:YAG laser capsulotomy was also the same between the groups. No significant difference was found in mean visual acuity between the two IOL groups during the follow-up, and there was no significant difference in photopic or mesopic contrast visual acuity with and without a glare source at 1 and 24 months after surgery. CONCLUSION The degree of PCO in eyes with an AcrySof IOL are almost the same as that in eyes with a Sensar IOL, with the results that visual acuity and contrast sensitivity with and without glare are similar.
Collapse
Affiliation(s)
- K Hayashi
- Private Hospital of Ophthalmology, Hayashi Eye Hospital, Hakata-Ku, Fukuoka, Japan.
| | | | | |
Collapse
|
47
|
Mingels A, Koch J, Lommatzsch A, Pauleikhoff D, Heiligenhaus A. Comparison of two acrylic intraocular lenses with different haptic designs in patients with combined phacoemulsification and pars plana vitrectomy. Eye (Lond) 2006; 21:1379-83. [PMID: 16763658 DOI: 10.1038/sj.eye.6702446] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
PURPOSE The intra- and postoperative characteristics of two foldable single-piece intraocular lenses (IOL) with identical hydrophilic acrylic material, but different haptic designs (Akreos Adapt and Akreos Fit), were compared in combined phacoemulsification and pars plana vitrectomy (PPV). METHODS This was a prospective, randomized study in patients with simultaneous cataract and vitreoretinal surgery. Group A (n=47 patients) included implantation of Akreos Fit IOL (two-point haptic) and group B (n=46 patients) implantation of Akreos Adapt IOL (four-point haptic). All intraoperative modifications of small-incision phacoemulsification and three-port PPV and IOL implantation and centration were documented. At 1 and 2 days and 6 months after surgery, best-corrected visual acuity (BCVA), slit-lamp appearance (including inflammation, IOL centration, capsulorhexis diameter, posterior capsule opacification (PCO), tonometry, and fundus findings were evaluated. RESULTS The groups did not differ with respect to age, surgical indications and modifications, intraoperative IOL handling, and centration. At day 2, inflammation and capsulorhexis diameters were similar, but IOL decentration was slightly more frequent with Akreos-Fit IOLs. Six months after surgery, the rates of PCO, posterior synechiae, and BCVA were similar. Akreos-Fit had slightly smaller capsulorhexis diameters and slightly more capsular contraction and IOL decentration (P>0.05). CONCLUSIONS Both of the Akreos IOL are feasible for combined phacoemulsification and PPV. Although similar in intraoperative handling, BCVA, and PCO, IOL centration was slightly better with Akreos-Adapt than with Akreos-Fit after combined surgery.
Collapse
Affiliation(s)
- A Mingels
- Department of Ophthalmology at St Franziskus Hospital, Muenster, Germany
| | | | | | | | | |
Collapse
|
48
|
Hayashi K, Yoshida M, Hayashi H. Posterior capsule opacification in myopic eyes. J Cataract Refract Surg 2006; 32:634-8. [PMID: 16698486 DOI: 10.1016/j.jcrs.2006.01.017] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2005] [Accepted: 03/23/2005] [Indexed: 10/24/2022]
Abstract
PURPOSE To determine whether posterior capsule opacification (PCO) is extensive in eyes with myopia or long axial length when an intraocular lens (IOL) of low-power, zero-power, or minus-power, is implanted. SETTING Hayashi Eye Hospital, Fukuoka, Japan. METHODS Ninety eyes of 90 patients scheduled for phacoemulsification surgery were recruited. These consisted of 30 eyes with high (> or =-8 diopters [D]) myopia, 30 eyes with moderate (<-8 D and > or =-3 D) myopia, and 30 eyes with low (<-3 D) myopia. All eyes had implantation of an acrylic IOL-low-power, zero-power, or minus-power-with a sharp optic edge (AcrySof MA60BM or MA60MA, Alcon Surgical). The PCO in these eyes was measured using a Scheimpflug videophotography system (EAS-1000, Nidek) 1, 3, 6, 12, 18, and 24 months after surgery. Visual acuity and the incidence of neodymium:YAG (Nd:YAG) laser posterior capsulotomy were also examined. RESULTS No significant difference was observed in the mean PCO value or in the Nd:YAG capsulotomy rate between the high myopia, moderate myopia, or low myopia groups throughout the follow-up period. There was also no significant correlation between PCO value and the actual spherical power or axial length of the eye. Furthermore, although mean visual acuity tended to be worse in proportion to the degree of myopia, the difference was not statistically significant. CONCLUSION When an acrylic IOL of low-power, zero-power, or minus-power with a sharp optic edge was implanted, high myopia and long axial length were not associated with the degree of PCO.
Collapse
Affiliation(s)
- Ken Hayashi
- Hayashi Eye Hospital, School of Medicine, Fukuoka University, Fukuoka, Japan.
| | | | | |
Collapse
|
49
|
Smith AF, Lafuma A, Berdeaux G, Berto P, Brueggenjuergen B, Magaz S, Auffarth GK, Brezin A, Caporossi A, Mendicute J. Cost-effectiveness analysis of PMMA, silicone, or acrylic intra-ocular lenses in cataract surgery in four European countries. Ophthalmic Epidemiol 2005; 12:343-51. [PMID: 16272054 DOI: 10.1080/09286580500180598] [Citation(s) in RCA: 14] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
PURPOSE To compare the cost-effectiveness of different intra-ocular lens (IOL) materials (Hydrophobic acrylic, Polymethylmethacrylate (PMMA), Hydrophilic acrylic and Silicone) implanted after cataract surgery with reference to Nd:YAG laser capsulotomy and Nd:YAG-related complications in four European countries (France, Italy, Germany and Spain). SETTING A retrospective review of 1,525 patients (eyes), aged 50 to 80 years, operated with phacoemulsification for cataract in 1996 or 1997 in 16 surgical centres (4 per country). METHODS The study was conducted using a cost-effectiveness approach. Medical charts were reviewed to collect retrospective information during the 3-year period following cataract surgery in order to identify patients who underwent Nd:YAG laser capsulotomy post-operatively. Clinical data were combined with unit costs assessed by experts for Nd:YAG laser capsulotomy and their complications. A cost-effectiveness ratio (cost per patient without Nd:YAG laser capsulotomy intervention) was estimated in relation to each IOL material used in each of the four European countries. RESULTS Hydrophobic acrylic, specifically Acrysof, was the most cost-effective IOL material in all the countries except Germany where it was second. PMMA had the best ratio in Germany, was second in Spain and only third in Italy and France. Silicone was second in France and ranked third in the other countries, while hydrophilic acrylic had the worst ratio overall in all countries. CONCLUSIONS Cost-effectiveness ratios of hydrophobic acrylic (Acrysof) were better than those of other types of IOL materials used in most of the countries. Sensitivity analyses were performed to vary the base case analysis to demonstrate the economic importance of the assumptions. In all cases, hydrophobic acrylic IOL material was shown to be a highly cost-effective option.
Collapse
Affiliation(s)
- Andrew F Smith
- Health Economics Unit, Alcon Laboratories Ltd., Hemel Hempstead, England, UK.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
50
|
Nanavaty MA, Vasavada AR, Zetterström C. Phakic IOL implantation versus clear lens extraction in highly myopic eyes. J Cataract Refract Surg 2005; 31:2041. [PMID: 16412901 DOI: 10.1016/j.jcrs.2005.12.011] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|