1
|
Left atrial appendage orifice dimensions in Japanese atrial fibrillation population measured by multiplane transesophageal echocardiography. J Echocardiogr 2022; 20:201-207. [PMID: 35587331 DOI: 10.1007/s12574-022-00575-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/01/2021] [Revised: 03/14/2022] [Accepted: 03/29/2022] [Indexed: 10/18/2022]
Abstract
BACKGROUND Successful implantation of the WATCHMAN device requires an accurate understanding of left atrial appendage (LAA) anatomy and orifice dimensions. Racial differences are observed in LAA size when comparing Asians with non-Asians. METHODS A total of 170 patients (123 male, 67.4 ± 9.2 years) with paroxysmal or persistent atrial fibrillation (AF) underwent transesophageal echocardiography before catheter ablation or cardioversion (September 2018 to September 2019). As per the recommendations of the WATCHMAN device, the maximal LAA ostial diameters were measured at multiplane angles of 0°, 45°, 90°, and 135°. RESULTS The majority of patients (121/170, 71%) had an LAA orifice size within 17-25 mm. Fifteen (8.8%) patients had undersized (< 17 mm) and eight (0.5%) had oversized (> 31 mm) LAA. One patient in this population had no LAA. LAA size was significantly larger in patients with persistent AF than in those with paroxysmal AF (23.3 ± 4.2 mm vs. 20.0 ± 3.0 mm, p < 0.001) and in male patients than in female patients (22.4 ± 4.2 vs. 20.9 ± 3.7 mm, p = 0.03). LAA orifice dimension was significantly correlated with CHADS2 score, the left atrial volume (LAV), E/e', and the left ventricular ejection fraction. Persistent AF, body mass index, and LAV were independently associated with LAA orifice dimension in multivariate analysis. CONCLUSION This study demonstrated the distribution of LAA orifice dimension in the Japanese AF patients. This finding should be used as a reference to understand the racial characteristics of LAA size for the WATCHMAN procedure.
Collapse
|
2
|
Borde D, Chidambaram K, Sundar AS, Kulkarni V, Jasapara A, Shetty V, Gopinath R, Pathy A, Viswanath VVR, Asegaonkar B, Apsingkar P, Takalkar U, Joshi S, Chakravarthy M. Normative Transesophageal Echocardiographic Values of Cardiac Structures in the Indian Population-Indian Normative TEE Measurements (INTEEM) Study. J Cardiothorac Vasc Anesth 2021; 36:184-194. [PMID: 34344599 DOI: 10.1053/j.jvca.2021.07.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 06/16/2021] [Accepted: 07/05/2021] [Indexed: 11/11/2022]
Abstract
OBJECTIVES Information on normative reference values for cardiac structures is critical for the accurate application of echocardiography for guiding clinical decision-making. Many studies using transthoracic echocardiography (TTE) have shown that Indians have smaller diameters of various cardiac structures. There are no normative studies for transesophageal echocardiography (TEE). The authors observed dimensions of various cardiac structures in healthy Indian patients under general anesthesia using TEE and compared them with existing guidelines from non-Indian data. DESIGN The Indian Normative TEE Measurements study was a multicenter, prospective observational study conducted in India. SETTING Operating rooms for noncardiac surgeries in tertiary care-level hospitals. PARTICIPANTS Adult patients undergoing noncardiac surgery who were free from any cardiac, respiratory, and renal diseases and had no contraindications for TEE. INTERVENTIONS After inducing general anesthesia and achieving stable hemodynamic conditions, a comprehensive TEE examination was performed and various measurements were made. MEASUREMENTS AND MAIN RESULTS For each of the 83 patients undergoing noncardiac surgery, 39 various measurements for left ventricle, right ventricle, both atria, and all valves were made. This included diameters and functional parameters. They were analyzed in a vendor-neutral software off-line. The absolute values of many of the measurements were higher in men, but when indexed to body surface area (BSA) they were similar in both sexes. The values were lower than most of the Western data but matched previous Indian studies using TTE. CONCLUSIONS The authors present normative values of various echocardiographic parameters using TEE. Because of its variations, it is recommended to use India-specific data to make decisions in Indian patients. It may be prudent to use BSA-indexed values during decision-making.
Collapse
Affiliation(s)
- Deepak Borde
- Department of Cardiac Anesthesia, Ozone Anesthesia Group, Aurangabad, Maharashtra, India.
| | - Kumar Chidambaram
- Department of Cardiac Anesthesia, Madras Medical Mission, Chennai, Tamilnadu, India
| | - Ayya Syama Sundar
- Department of Cardiac Anesthesia, Nizam's Institute of Medical Sciences, Hyderabad, Telanagana, India; Department of Anesthesiology, All India Institute of Medical Sciences, Bibinagar, Hyderabad, Telangana, India
| | - Venugopal Kulkarni
- Department of Cardiac Anesthesia, Citizen's Hospital, Hyderabad, Telangana, India
| | - Amish Jasapara
- Department of Cardiac Anesthesia, Fortis Hospitals, Mulund, Mumbai, Maharashtera, India
| | - Vijay Shetty
- Department of Cardiac Anesthesia, Fortis Hospitals, Mulund, Mumbai, Maharashtera, India
| | - Ramachandra Gopinath
- Department of Cardiac Anesthesia, Nizam's Institute of Medical Sciences, Hyderabad, Telanagana, India; Department of Anesthesiology, ESIC Medical College and Super Speciality Hospital, Hyderabad, Telangana, India
| | - Archana Pathy
- Department of Cardiac Anesthesia, Nizam's Institute of Medical Sciences, Hyderabad, Telanagana, India
| | - V V Raja Viswanath
- Department of Cardiac Anesthesia, Citizen's Hospital, Hyderabad, Telangana, India
| | - Balaji Asegaonkar
- Department of Cardiac Anesthesia, Ozone Anesthesia Group, Aurangabad, Maharashtra, India
| | - Pramod Apsingkar
- Department of Cardiac Anesthesia, Ozone Anesthesia Group, Aurangabad, Maharashtra, India
| | - Unmesh Takalkar
- Department of Surgery, United CIIGMA Hospital, Aurangabad, Maharashtra, India
| | - Shreedhar Joshi
- Department of Cardiac Anesthesia, Narayana Institute of Cardiac Sciences, Bengaluru, Karnataka, India
| | - Murali Chakravarthy
- Department of Cardiac Anesthesia, Fortis Hospitals, Bengaluru, Karnataka, India
| |
Collapse
|
3
|
Alakhtar A, Emmott A, Hart C, Mongrain R, Leask RL, Lachapelle K. 3D printed ascending aortic simulators with physiological fidelity for surgical simulation. BMJ SIMULATION & TECHNOLOGY ENHANCED LEARNING 2021; 7:536-542. [DOI: 10.1136/bmjstel-2021-000868] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Accepted: 05/28/2021] [Indexed: 11/04/2022]
Abstract
IntroductionThree-dimensional (3D) printed multimaterial ascending aortic simulators were created to evaluate the ability of polyjet technology to replicate the distensibility of human aortic tissue when perfused at physiological pressures.MethodsSimulators were developed by computer-aided design and 3D printed with a Connex3 Objet500 printer. Two geometries were compared (straight tube and idealised aortic aneurysm) with two different material variants (TangoPlus pure elastic and TangoPlus with VeroWhite embedded fibres). Under physiological pressure, β Stiffness Index was calculated comparing stiffness between our simulators and human ascending aortas. The simulators’ material properties were verified by tensile testing to measure the stiffness and energy loss of the printed geometries and composition.ResultsThe simulators’ geometry had no effect on measured β Stiffness Index (p>0.05); however, β Stiffness Index increased significantly in both geometries with the addition of embedded fibres (p<0.001). The simulators with rigid embedded fibres were significantly stiffer than average patient values (41.8±17.0, p<0.001); however, exhibited values that overlapped with the top quartile range of human tissue data suggesting embedding fibres can help replicate pathological human aortic tissue. Biaxial tensile testing showed that fiber-embedded models had significantly higher stiffness and energy loss as compared with models with only elastic material for both tubular and aneurysmal geometries (stiffness: p<0.001; energy loss: p<0.001). The geometry of the aortic simulator did not statistically affect the tensile tested stiffness or energy loss (stiffness: p=0.221; energy loss: p=0.713).ConclusionWe developed dynamic ultrasound-compatible aortic simulators capable of reproducing distensibility of real aortas under physiological pressures. Using 3D printed composites, we are able to tune the stiffness of our simulators which allows us to better represent the stiffness variation seen in human tissue. These models are a step towards achieving better simulator fidelity and have the potential to be effective tools for surgical training.
Collapse
|
4
|
Li S, Zhuang B, Yin G, Yang X, Zhao S, Lu M. Reference values of thoracic aorta and pulmonary artery diameters by age and gender in healthy Chinese adults assessed by cardiac magnetic resonance imaging: data from national center for cardiovascular diseases of China. Int J Cardiovasc Imaging 2021; 37:1423-1431. [PMID: 33392881 DOI: 10.1007/s10554-020-02116-9] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/16/2020] [Accepted: 11/22/2020] [Indexed: 10/22/2022]
Abstract
The aim of the study was to define normal ranges for thoracic aorta and pulmonary artery diameters relative to gender, age, body surface area (BSA) and body mass index (BMI) in healthy Chinese adults by cardiac magnetic resonance (CMR). We studied 200 healthy participants (100 men, 100 women; age range from 20-70) by using a 3.0-T CMR system. The diameters of the ascending aorta (AA), main pulmonary artery (PA), proximal descending aorta (DA) and Valsalva sinus (VAS) were measured manually by two experienced doctors on half-Fourier single-shot spin echo (HASTE) and balanced steady-state free precession (bSSFP) cine images. The mean value and age specific and gender adjusted normal limits were calculated. The linear regression analysis were performed between diameters and gender, age, BMI and BSA. The mean and 95% confidence interval(CI) of AA, PA, DA and VAS were 28.95 ± 4.61 mm(95% CI 19.92-37.99 mm), 22.41 ± 2.59 mm(95% CI 17.31-27.47 mm), 20.61 ± 2.96 mm(95% CI 14.81-26.42 mm), 31.15 ± 3.65 mm(95% CI 24.00-38.29 mm), respectively. The gender differences of all the parameters above were statistically significant (all p < 0.01). Both thoracic aorta and pulmonary artery dilates with the increase of age, while AA has the highest dilation rate. The mean PA/AA was 0.79 and showed no gender difference, but there was statistical difference among all age groups (p < 0.01). AA and DA had stronger association with age and BSA than BMI. Age- and gender-specific reference diameters of thoracic aorta and pulmonary artery were provided in healthy Chinese adults. Age and BSA have stronger effects on the ranges of diameters than BMI.
Collapse
Affiliation(s)
- Shuang Li
- Department of Magnetic Resonance Imaging, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100037, China
| | - Baiyan Zhuang
- Department of Magnetic Resonance Imaging, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100037, China
| | - Gang Yin
- Department of Magnetic Resonance Imaging, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100037, China.,Key Laboratory of Cardiovascular Imaging (Cultivation), Chinese Academy of Medical Sciences, Beijing, 100037, China
| | - Xinling Yang
- Department of Magnetic Resonance Imaging, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100037, China.,Key Laboratory of Cardiovascular Imaging (Cultivation), Chinese Academy of Medical Sciences, Beijing, 100037, China
| | - Shihua Zhao
- Department of Magnetic Resonance Imaging, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100037, China
| | - Minjie Lu
- Department of Magnetic Resonance Imaging, State Key Laboratory of Cardiovascular Disease, National Center for Cardiovascular Diseases, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100037, China. .,Key Laboratory of Cardiovascular Imaging (Cultivation), Chinese Academy of Medical Sciences, Beijing, 100037, China.
| |
Collapse
|
5
|
Difficult Internal Jugular Central Venous Cannulation Using J-Tip Guidewire with Indwelling Peripherally Inserted Central Venous Catheters. Case Rep Anesthesiol 2019; 2019:5134575. [PMID: 31428478 PMCID: PMC6679875 DOI: 10.1155/2019/5134575] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/30/2019] [Accepted: 07/09/2019] [Indexed: 11/18/2022] Open
Abstract
Central venous cannulation is a commonly performed procedure while managing critically ill patients; increasingly we encounter patients with indwelling wires or devices, like pacemakers, implantable cardioverter defibrillator devices, and peripherally inserted central venous catheters which complicate insertion of central venous catheters further. We present two cases where use of standard J-tip guidewire may have exacerbated the difficulty associated with internal jugular cannulation in presence of peripherally inserted central venous catheters. Recognition and avoidance of possible complications are crucial, and we discuss complexity posed by indwelling peripherally inserted central venous catheters and possible solutions.
Collapse
|
6
|
Pham MHC, Ballegaard C, de Knegt MC, Sigvardsen PE, Sørgaard MH, Fuchs A, Kühl JT, Taudorf M, Nordestgaard BG, Køber LV, Kofoed KF. Normal values of aortic dimensions assessed by multidetector computed tomography in the Copenhagen General Population Study. Eur Heart J Cardiovasc Imaging 2019; 20:939-948. [DOI: 10.1093/ehjci/jez012] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2018] [Accepted: 01/22/2019] [Indexed: 12/21/2022] Open
Abstract
Abstract
Aims
Accurate assessment of aortic dimensions can be achieved using contrast-enhanced computed tomography. The aim of this study was to define normal values and determinants of aortic dimensions throughout multiple key anatomical landmarks of the aorta in healthy individuals from the Copenhagen General Population Study.
Methods and results
The study group consisted of 902 healthy subjects selected from 3000 adults undergoing cardiovascular thoracic and abdominal computed tomography-angiography (CTA), where systematic measurements of aortic dimensions were performed retrospectively. Individuals included were without any of the following predefined cardiovascular risk factors: (i) self-reported angina pectoris; (ii) hypertension; (iii) hypercholesterolaemia; (iv) taking cardiovascular prescribed medication including diuretics, statins, or aspirin; (v) overweight (defined as body mass index ≥30 kg/m2); (vi) diabetes mellitus (self-reported or blood glucose >8 mmol/L); and (vii) chronic obstructive pulmonary disease. Maximal aortic diameters were measured at seven aortic regions: sinuses of Valsalva, sinotubular junction, ascending aorta, mid-descending aorta, abdominal aorta at the diaphragm, abdominal aorta at the coeliac trunk, and infrarenal abdominal aorta. Median age was 52 years, and 396 (40%) were men. Men had significantly larger aortic diameters at all levels compared with women (P < 0.001). Multivariable analysis revealed that sex, age, and body surface area were associated with increasing aortic dimensions.
Conclusion
Normal values of maximal aortic dimensions at key aortic anatomical locations by contrast-enhanced CTA have been defined. Age, sex, and body surface area were significantly associated with these measures at all levels of aorta. Aortic dimensions follow an almost identical pattern throughout the vessel regardless of sex.
Collapse
Affiliation(s)
- Michael H C Pham
- Department of Cardiology, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Christian Ballegaard
- Department of Cardiology, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Martina C de Knegt
- Department of Cardiology, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Per E Sigvardsen
- Department of Cardiology, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Mathias H Sørgaard
- Department of Cardiology, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Andreas Fuchs
- Department of Cardiology, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Jørgen T Kühl
- Department of Cardiology, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Mikkel Taudorf
- Department of Radiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| | - Børge G Nordestgaard
- Department of Clinical Biochemistry and the Copenhagen General Population Study, Herlev Hospital, University of Copenhagen, Copenhagen, Denmark
| | - Lars V Køber
- Department of Cardiology, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen, Denmark
| | - Klaus F Kofoed
- Department of Cardiology, Rigshospitalet, Faculty of Health and Medical Sciences, University of Copenhagen, Blegdamsvej 9, 2100 Copenhagen, Denmark
- Department of Radiology, Rigshospitalet, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
7
|
Experimental Study of Right Ventricular Hemodynamics After Tricuspid Valve Replacement Therapies to Treat Tricuspid Regurgitation. Cardiovasc Eng Technol 2017; 8:401-418. [DOI: 10.1007/s13239-017-0328-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/14/2017] [Accepted: 08/21/2017] [Indexed: 10/19/2022]
|
8
|
Abstract
Transesophageal echocardiography (TEE) provides high-resolution images of the mitral valve apparatus, permitting detailed evaluation of its structure and function. Mitral valve evaluation is invaluable during mitral valve repair surgery, providing insight into the mechanism of valve dysfunction and formulation of a plan for repair. TEE provides immediate detection of inadequate repair after bypass and allows correction during the same operative setting. Intraoperative TEE is a valuable tool for improving patient outcome and offers the cardiovascular anesthesiologist a role in perioperative surgical decisions.
Collapse
|
9
|
Schenone E, Collin A, Gerbeau JF. Numerical simulation of electrocardiograms for full cardiac cycles in healthy and pathological conditions. INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN BIOMEDICAL ENGINEERING 2016; 32:e02744. [PMID: 26249327 DOI: 10.1002/cnm.2744] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/09/2014] [Revised: 07/29/2015] [Accepted: 08/03/2015] [Indexed: 06/04/2023]
Abstract
This work is dedicated to the simulation of full cycles of the electrical activity of the heart and the corresponding body surface potential. The model is based on a realistic torso and heart anatomy, including ventricles and atria. One of the specificities of our approach is to model the atria as a surface, which is the kind of data typically provided by medical imaging for thin volumes. The bidomain equations are considered in their usual formulation in the ventricles, and in a surface formulation on the atria. Two ionic models are used: the Courtemanche-Ramirez-Nattel model on the atria and the 'minimal model for human ventricular action potentials' by Bueno-Orovio, Cherry, and Fenton in the ventricles. The heart is weakly coupled to the torso by a Robin boundary condition based on a resistor-capacitor transmission condition. Various electrocardiograms (ECGs) are simulated in healthy and pathological conditions (left and right bundle branch blocks, Bachmann's bundle block, and Wolff-Parkinson-White syndrome). To assess the numerical ECGs, we use several qualitative and quantitative criteria found in the medical literature. Our simulator can also be used to generate the signals measured by a vest of electrodes. This capability is illustrated at the end of the article. Copyright © 2015 John Wiley & Sons, Ltd.
Collapse
Affiliation(s)
- Elisa Schenone
- Sorbonne Universités UPMC, Paris, France
- Inria Paris-Rocquencourt, Paris, France
| | | | | |
Collapse
|
10
|
Amir R, Yeh L, Montealegre-Gallegos M, Saraf R, Matyal R, Mahmood F. A Tight Spot After Pulmonary Vein Catheter Ablation. J Cardiothorac Vasc Anesth 2016; 30:1748-1749. [PMID: 27542905 DOI: 10.1053/j.jvca.2016.04.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/22/2016] [Indexed: 11/11/2022]
Affiliation(s)
- Rabia Amir
- Department of *Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | - Lu Yeh
- Department of *Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA; Department of Anesthesia and Pain Medicine, University of Groningen, University Medical Center Groningen, Groningen, The Netherlands
| | - Mario Montealegre-Gallegos
- Department of *Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | - Rabya Saraf
- Department of Surgery, Division of Cardiac Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | - Robina Matyal
- Department of *Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA
| | - Feroze Mahmood
- Department of *Anesthesia, Critical Care and Pain Medicine, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA.
| |
Collapse
|
11
|
Miglioranza MH, Mihăilă S, Muraru D, Cucchini U, Iliceto S, Badano LP. Dynamic Changes in Tricuspid Annular Diameter Measurement in Relation to the Echocardiographic View and Timing during the Cardiac Cycle. J Am Soc Echocardiogr 2015; 28:226-35. [DOI: 10.1016/j.echo.2014.09.017] [Citation(s) in RCA: 45] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/06/2014] [Indexed: 11/15/2022]
|
12
|
Variability of Tricuspid Annulus Diameter Measurement in Healthy Volunteers. JACC Cardiovasc Imaging 2014; 8:864-6. [PMID: 25459303 DOI: 10.1016/j.jcmg.2014.09.010] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/15/2014] [Revised: 08/28/2014] [Accepted: 09/02/2014] [Indexed: 11/22/2022]
|
13
|
Tan CO, Harley I. Perioperative Transesophageal Echocardiographic Assessment of the Right Heart and Associated Structures: A Comprehensive Update and Technical Report. J Cardiothorac Vasc Anesth 2014; 28:1100-21. [DOI: 10.1053/j.jvca.2013.05.031] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/28/2013] [Indexed: 11/11/2022]
|
14
|
Transesophageal Echocardiography in Healthy Young Adult Male Baboons ( Papio hamadryas anubis): Normal Cardiac Anatomy and Function in Subhuman Primates Compared to Humans. PROGRESS IN PEDIATRIC CARDIOLOGY 2013; 35:109-120. [PMID: 24707162 DOI: 10.1016/j.ppedcard.2013.09.002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Implantable, viable tissue engineered cardiovascular constructs are rapidly approaching clinical translation. Species typically utilized as preclinical large animal models are food stock ungulates for which cross species biological and genomic differences with humans are great. Multiple authorities have recommended developing subhuman primate models for testing regenerative surgical strategies to mitigate xenotransplant inflammation. However, there is a lack of specific quantitative cardiac imaging comparisons between humans and the genomically similar baboons (Papio hamadryas anubis). This study was undertaken to translate to baboons transesophageal echocardiographic functional and dimensional criteria defined as necessary for defining cardiac anatomy and function in the perioperative setting. Seventeen young, healthy baboons (approximately 30 kg, similar to 5 year old children) were studied to determine whether the requisite 11 views and 52 measurement parameters could be reliably acquired by transesophageal echocardiography (TEE). The obtained measurements were compared to human adult normative literature values and to a large relational database of pediatric "normal heart" echo measurements. Comparisons to humans, when normalized to BSA, revealed a trend in baboons toward larger mitral and aortic valve effective orifice areas and much larger left ventricular muscle mass and wall thickness, but similar pulmonary and tricuspid valves. By modifying probe positioning relative to human techniques, all recommended TEE views except transgastric could be replicated. To supplement, two transthoracic apical views were discovered that in baboons could reliably replace the transgastric TEE view. Thus, all requisite echo views could be obtained for a complete cardiac evaluation in Papio hamadryas anubis to noninvasively quantify cardiac structural anatomy, physiology, and dimensions. Despite similarities between the species, there are subtle and important physiologic and anatomic differences when compared to human.
Collapse
|
15
|
Tobón C, Rodríguez JF, Ferrero JM, Hornero F, Saiz J. Dominant frequency and organization index maps in a realistic three-dimensional computational model of atrial fibrillation. Europace 2013; 14 Suppl 5:v25-v32. [PMID: 23104911 DOI: 10.1093/europace/eus268] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/14/2022] Open
Abstract
AIMS To study, using simulation, the spectral characteristics of different patterns of atrial fibrillation (AF) at high spatial resolution. Dominant frequency (DF) and organization index (OI) maps have been used to approximate the location of the focal source of high frequency during AF events. METHODS AND RESULTS A realistic three-dimensional model of the human atria that includes fibre orientation, electrophysiological heterogeneity, and anisotropy was implemented. The cellular model was modified to simulate electrical remodelling. More than 43 000 electrograms were calculated on the surface, and were processed to reconstitute the DF and OI maps. Atrial fibrillation episodes were triggered by a source of transitory and of continuous activity (both with a cycle length of 130 ms) in five different locations. The maps obtained during the AF events triggered by transitory foci did not show areas with high DF or OI values. When continuous foci were applied, the DF maps show ample zones with high values in the atrium where the focus was applied; while OI maps display smaller areas with high values, always within the areas of high DF and, in three of five locations, this high-value area was located at the site of focus application and at the nearby area. In the other two locations, the area presenting the highest OI values is small and located at the site of focus application, which allowed its precise localization. CONCLUSION Organization index maps provide a better approximation than DF maps for the localization of ectopic sources of high frequency and continuous activity during episodes of simulated AF in remodelled tissue.
Collapse
Affiliation(s)
- Catalina Tobón
- Universitat Politècnica de València, Camino de Vera s/n, Valencia, Spain
| | | | | | | | | |
Collapse
|
16
|
Tobón C, Ruiz-Villa CA, Heidenreich E, Romero L, Hornero F, Saiz J. A three-dimensional human atrial model with fiber orientation. Electrograms and arrhythmic activation patterns relationship. PLoS One 2013; 8:e50883. [PMID: 23408928 PMCID: PMC3569461 DOI: 10.1371/journal.pone.0050883] [Citation(s) in RCA: 65] [Impact Index Per Article: 5.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2012] [Accepted: 10/25/2012] [Indexed: 11/19/2022] Open
Abstract
The most common sustained cardiac arrhythmias in humans are atrial tachyarrhythmias, mainly atrial fibrillation. Areas of complex fractionated atrial electrograms and high dominant frequency have been proposed as critical regions for maintaining atrial fibrillation; however, there is a paucity of data on the relationship between the characteristics of electrograms and the propagation pattern underlying them. In this study, a realistic 3D computer model of the human atria has been developed to investigate this relationship. The model includes a realistic geometry with fiber orientation, anisotropic conductivity and electrophysiological heterogeneity. We simulated different tachyarrhythmic episodes applying both transient and continuous ectopic activity. Electrograms and their dominant frequency and organization index values were calculated over the entire atrial surface. Our simulations show electrograms with simple potentials, with little or no cycle length variations, narrow frequency peaks and high organization index values during stable and regular activity as the observed in atrial flutter, atrial tachycardia (except in areas of conduction block) and in areas closer to ectopic activity during focal atrial fibrillation. By contrast, cycle length variations and polymorphic electrograms with single, double and fragmented potentials were observed in areas of irregular and unstable activity during atrial fibrillation episodes. Our results also show: (1) electrograms with potentials without negative deflection related to spiral or curved wavefronts that pass over the recording point and move away, (2) potentials with a much greater proportion of positive deflection than negative in areas of wave collisions, (3) double potentials related with wave fragmentations or blocking lines and (4) fragmented electrograms associated with pivot points. Our model is the first human atrial model with realistic fiber orientation used to investigate the relationship between different atrial arrhythmic propagation patterns and the electrograms observed at more than 43000 points on the atrial surface.
Collapse
Affiliation(s)
- Catalina Tobón
- Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano (I3BH), Universitat Politècnica de València, Valencia, Spain
| | - Carlos A. Ruiz-Villa
- Departamento de Sistemas, Universidad de Caldas, Manizales, Caldas, Colombia
- Departamento de Informática y Computación, Universidad Nacional de Colombia Sede Manizales, Manizales, Caldas, Colombia
| | | | - Lucia Romero
- Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano (I3BH), Universitat Politècnica de València, Valencia, Spain
| | - Fernando Hornero
- Servicio Cirugía Cardiaca, Hospital General de Valencia, Valencia, Spain
| | - Javier Saiz
- Instituto Interuniversitario de Investigación en Bioingeniería y Tecnología Orientada al Ser Humano (I3BH), Universitat Politècnica de València, Valencia, Spain
| |
Collapse
|
17
|
Jacquemet V, Kappenberger L, Henriquez CS. Modeling atrial arrhythmias: impact on clinical diagnosis and therapies. IEEE Rev Biomed Eng 2012; 1:94-114. [PMID: 22274901 DOI: 10.1109/rbme.2008.2008242] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Atrial arrhythmias are the most frequent sustained rhythm disorders in humans and often lead to severe complications such as heart failure and stroke. Despite the important insights provided by animal models into the mechanisms of atrial arrhythmias, direct translation of experimental findings to new therapies in patients has not been straightforward. With the advances in computer technology, large-scale electroanatomical computer models of the atria that integrate information from the molecular to organ scale have reached a level of sophistication that they can be used to interpret the outcome of experimental and clinical studies and aid in the rational design of therapies. This paper reviews the state-of-the-art of computer models of the electrical dynamics of the atria and discusses the evolving role of simulation in assisting the clinical diagnosis and treatment of atrial arrhythmias.
Collapse
Affiliation(s)
- Vincent Jacquemet
- Department of Biomedical Engineering, Duke University, Durham, NC 27708, USA.
| | | | | |
Collapse
|
18
|
Cheng CM, Huang JL, Wu TJ, Su CS, Pai HY, Liao MF, Ting CT, Chen SA. Novel tips for engaging the coronary sinus guided by right ventricular lead. Europace 2012; 14:1754-8. [PMID: 22711762 DOI: 10.1093/europace/eus192] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022] Open
Abstract
AIMS This study investigated the relationship between the ostia of the coronary sinus (CS) and the tricuspid annulus (TA) for CS cannulation using a right ventricular (RV) lead, which could map out the TA by forming a curve when placed at the apex or low septum. METHODS AND RESULTS Seventy patients (45 males, 67 ± 12 years) who were admitted for CRT device implant were included in the evaluation of the relationship between the CS ostia and TA. An electrophysiological (EP) mapping catheter was used to probe the CS. The ostium was shown by the CS venography at the left anterior oblique (LAO) 20° and caudal 20°. Local electrograms were collected with CS catheters in the CS or RV. Transthoracic echocardiography was evaluated before each procedure. All CS ostia were located within 3.75 cm around the tip of TA. Sixty-two subjects (Group I, 89%) had CS ostia located under the TA. Eight patients (Group II) with CS ostia over the TA revealed larger left ventricular (LV) size and a smaller ratio of left atrium (LA)/LV size. LV enlargement predicted the presence of CS ostia over the TA. Typical CS electrograms were used to further confirm if the EP catheter was in the CS in all the subjects. CONCLUSION Use of the RV lead revealed that the CS ostia had a close relationship with the TA.
Collapse
Affiliation(s)
- Chien-Ming Cheng
- Division of Cardiology, Department of Medicine, Department of Health of Executive Yuan, Fong Yuan Hospital
| | | | | | | | | | | | | | | |
Collapse
|
19
|
Do we have two hearts? New insights in right ventricular function supported by myocardial imaging echocardiography. Heart Fail Rev 2010; 15:39-61. [PMID: 19866357 DOI: 10.1007/s10741-009-9154-x] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Abstract
RV performance is difficult to evaluate, given its geometry, interrelationship with the left ventricle, and sensitivity to alterations in pulmonary pressure. This article focuses on some of the challenges related to the assessment of RV function in the setting of the RV's unique anatomic, physiologic, conventional and newer echocardiographic aspects, and therapeutic implications. The majority of proposed methods of echocardiographic assessment of RV function are based on volumetric approximations of the RV. Such approaches have inherent limitations, first as volume-related measures such as EF are load dependent, second because of the complex geometry of the RV. The issue of RV geometry is usually overcome using geometry-independent parameters such as tricuspid annular excursion and the Tei index. The recent introduction of real-time three-dimensional echocardiography and myocardial imaging echocardiography (tissue Doppler imaging, 1D-strain and 2D-strain echocardiography) implied a great progress in echocardiography. Tissue Doppler imaging allows the quantitative assessment of RV systolic and diastolic function by means of measurement of myocardial velocities. Strain measurements have been shown to correlate well with sonomicrometry segment length measurements both in the inflow and outflow tract of the RV and under different loading conditions. Other findings have been reported in chronic and acute clinical settings. Standard and novel echocardiographic methods of assessment of RV size and performance can help clinicians in the treatment of acute and chronic RV failure and contribute to a better understanding of the peculiar chamber-related functional mechanisms in the context of ventricular interdependent independency.
Collapse
|
20
|
Wittkowski U, Spies C, Sander M, Erb J, Feldheiser A, von Heymann C. [Haemodynamic monitoring in the perioperative phase. Available systems, practical application and clinical data]. Anaesthesist 2009; 58:764-78, 780-6. [PMID: 19669105 DOI: 10.1007/s00101-009-1590-4] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
A regular hydration status and compensated vascular filling are targets of perioperative fluid and volume management and, in parallel, represent precautions for sufficient stroke volume and cardiac output to maintain tissue oxygenation. The physiological and pathophysiological effects of fluid and volume replacement mainly depend on the pharmacological properties of the solutions used, the magnitude of the applied volume as well as the timing of volume replacement during surgery. In the perioperative setting surgical stress induces physiological and hormonal adaptations of the body, which in conjunction with an increased permeability of the vascular endothelial layer influence fluid and volume management. The target of haemodynamic monitoring in the operation room is to collect data on haemodynamics and global oxygen transport, which enable the anaesthetist to estimate the volume status of the vascular system. Particularly in high risk patients this may improve fluid and volume therapy with respect to maintaining cardiac output. A goal-directed volume management aiming at preventing hypovolaemia may improve the outcome after surgery. The objective of this article is to review the monitoring devices that are currently used to assess haemodynamics and filling status in the perioperative setting. Methods and principles for measuring haemodynamic variables, the measured and calculated parameters as well as clinical benefits and shortcomings of each device are described. Furthermore, the results for monitoring devices from clinical studies of goal-directed fluid and volume therapy which have been published will be discussed.
Collapse
Affiliation(s)
- U Wittkowski
- Universitätsklinik für Anästhesiologie mit Schwerpunkt operative Intensivmedizin, Campus Virchow-Klinikum und Campus Charité Mitte, Charité - Universitätsmedizin Berlin, Berlin
| | | | | | | | | | | |
Collapse
|
21
|
Haddad F, Couture P, Tousignant C, Denault AY. The right ventricle in cardiac surgery, a perioperative perspective: I. Anatomy, physiology, and assessment. Anesth Analg 2009; 108:407-21. [PMID: 19151264 DOI: 10.1213/ane.0b013e31818f8623] [Citation(s) in RCA: 110] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The importance of right ventricular (RV) function in cardiovascular disease and cardiac surgery has been recognized for several years. RV dysfunction has been shown to be a significant prognostic factor in heart failure, congenital heart disease, valvular disease, and cardiac surgery. In the first of our two articles, we will review key features of RV anatomy, physiology, and assessment. In the first article, the main discussion will be centered on the echographic assessment of RV structure and function. In the second review article, pathophysiology, clinical importance, and management of RV failure in cardiac surgery will be discussed.
Collapse
Affiliation(s)
- François Haddad
- Department of Anesthesiology, Montreal Heart Institute, 5000 Bélanger St., Montreal, Quebec H1T 1C8, Canada
| | | | | | | |
Collapse
|
22
|
Lin FY, Devereux RB, Roman MJ, Meng J, Jow VM, Jacobs A, Weinsaft JW, Shaw LJ, Berman DS, Gilmore A, Callister TQ, Min JK. Assessment of the thoracic aorta by multidetector computed tomography: Age- and sex-specific reference values in adults without evident cardiovascular disease. J Cardiovasc Comput Tomogr 2008; 2:298-308. [DOI: 10.1016/j.jcct.2008.08.002] [Citation(s) in RCA: 106] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/03/2008] [Revised: 07/29/2008] [Accepted: 08/02/2008] [Indexed: 11/24/2022]
|
23
|
Mao SS, Ahmadi N, Shah B, Beckmann D, Chen A, Ngo L, Flores FR, Gao YL, Budoff MJ. Normal thoracic aorta diameter on cardiac computed tomography in healthy asymptomatic adults: impact of age and gender. Acad Radiol 2008; 15:827-34. [PMID: 18572117 DOI: 10.1016/j.acra.2008.02.001] [Citation(s) in RCA: 142] [Impact Index Per Article: 8.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2007] [Revised: 02/07/2008] [Accepted: 01/19/2008] [Indexed: 11/26/2022]
Abstract
RATIONALE AND OBJECTIVES To establish the normal criterion of ascending aortic diameter (AAOD) measured by 64 multidetector computed tomography (MDCT) and electron beam computed tomography (EBT) based on gender and age. MATERIALS AND METHODS A total of 1442 consecutive subjects who were referred for evaluation of possible coronary artery disease underwent coronary computed tomographic (CT) angiography (CTA) and coronary artery calcium scanning (CACS) (55 + 11 years, 65% male) without known coronary heart disease, hypertension, chronic pulmonary and renal disease, diabetes, and severe aortic calcification. The AAOD aortic diameter, descending aortic diameter (DAOD), pulmonary artery (PAD), and chest anteroposterior diameter (CAPD), posterior border of the sternal bone to the anterior border of the spine, were measured at the slice level of mid-right pulmonary artery using end systolic trigger imaging. The volume of four chambers, ejection fraction of left ventricle, and cardiac output were measured in 56% of the patients. Patients' demographic information, age, gender, weight, height, and body surface area were recorded. The mean value and age-specific and gender-adjusted upper normal limits (mean +/- 2 standard deviation) were calculated. The linear correlation analysis was done between AAOD and all parameters. The reproducibility, wall thickness, and difference between end-systole and end-diastole were calculated. RESULTS AAOD has significant linear association with age, gender, DAOD, and pulmonary artery diameter (P < .05). There is no significant correlation between AAOD and body surface area, four-chamber volume, left ventricular ejection fraction, cardiac output, and CAPD. The mean intraluminal AAOD was 31.1 +/- 3.9 and 33.6 +/- 4.1 mm in females and males, respectively. The upper normal limits (mean +/- 2 standard deviations) of intraluminal AAOD, were 35.6, 38.3, and 40 mm for females and 37.8, 40.5, and 42.6 mm for males in age groups 20-40, 41-60, and older than 60 years, respectively. Intraluminal aortic diameters should parallel echocardiography and invasive angiography. Traditional cross-sectional imaging (with CT and magnetic resonance imaging) includes the vessel wall. The mean total AAOD was 33.5 and 36.0 mm in females and males, respectively. The upper normal limits (mean +/- 2 standard deviations) of intraluminal AAOD were 38.0, 40.7 and 42.4 mm for females and 40.2, 42.9, and 45.0 mm for males in age group 20 to 40, 41 to 60, and older than 60 years, respectively. The inter- and intraobserver, scanner, and repeated measurement variabilities were low (r value >0.91, P < .001, coefficient variation <3.2%). AAOD was 1.7 mm smaller in end-diastole than end-systole (P < .001). CONCLUSIONS The AAOD increases with age and male gender. Gender-specific and age-adjusted normal values for aortic diameters are necessary to differentiate pathologic atherosclerotic changes in the ascending aorta. Use of intraluminal or total aortic diameter values depends on the comparison study employed.
Collapse
|
24
|
Segers P, Rietzschel ER, De Buyzere ML, Vermeersch SJ, De Bacquer D, Van Bortel LM, De Backer G, Gillebert TC, Verdonck PR. Noninvasive (input) impedance, pulse wave velocity, and wave reflection in healthy middle-aged men and women. Hypertension 2007; 49:1248-55. [PMID: 17404183 DOI: 10.1161/hypertensionaha.106.085480] [Citation(s) in RCA: 213] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
The relation between arterial function indices, such as pulse wave velocity and augmentation index with parameters derived from input impedance analysis, is still incompletely understood. Carotid pressure, central flow waveforms, and pulse wave velocity were noninvasively acquired in 2026 apparently healthy, middle-aged subjects (1052 women and 974 men) 35 to 55 years old at inclusion. Input and characteristic impedance, reflection coefficient, the ratio of backward-to-forward pressure amplitude (reflection magnitude), and augmentation index were derived. Pulse wave velocity increased by 15% (from 6.1 to 7.0 m/s) both in men and women. In qualitative terms, input impedance evolved from a pattern indicative of wave transmission and reflection to a pattern more compatible with a windkessel-like system. In women, a decrease in total arterial compliance led to an increased input impedance in the low frequency range, whereas few changes were observed in men. Characteristic impedance did not change with age in women and even decreased in men (P<0.001) and could not be identified as the primary determinant of central pulse pressure. Augmentation index increased with age, as was expected, and was systematically higher in women (P<0.001). Reflection coefficient and reflection magnitude increased with age (P<0.001) without gender differences. We conclude that, in healthy middle-aged subjects, the age-related increase in arterial stiffness (pulse wave velocity) is not fully paralleled by an increase in arterial impedance, suggesting a role for age-dependent modulation of aortic cross-sectional area. Wave reflection increases with age and is not higher in women than in men.
Collapse
Affiliation(s)
- Patrick Segers
- Cardiovascular Mechanics and Biofluid Dynamics, IBiTech, Ghent University, De Pintelaan 185, B-9000 Gent, Belgium.
| | | | | | | | | | | | | | | | | |
Collapse
|
25
|
Kuo SR, Trayanova NA. Action potential morphology heterogeneity in the atrium and its effect on atrial reentry: a two-dimensional and quasi-three-dimensional study. PHILOSOPHICAL TRANSACTIONS. SERIES A, MATHEMATICAL, PHYSICAL, AND ENGINEERING SCIENCES 2006; 364:1349-66. [PMID: 16766349 DOI: 10.1098/rsta.2006.1776] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
Atrial fibrillation (AF) is believed to be perpetuated by recirculating spiral waves. Atrial structures are often characterized with action potentials of varying morphologies; however, the role of the structure-dependent atrial electrophysiological heterogeneity in spiral wave behaviour is not well understood. The purpose of this study is to determine the effect of action potential morphology heterogeneity associated with the major atrial structures in spiral wave maintenance. The present study also focuses on how this effect is further modulated by the presence of the inherent periodicity in atrial structure. The goals of the study are achieved through the simulation of electrical behaviour in a two-dimensional atrial tissue model that incorporates the representation of action potentials in various structurally distinct regions in the right atrium. Periodic boundary conditions are then imposed to form a cylinder (quasi three-dimensional), thus allowing exploration of the additional effect of structure periodicity on spiral wave behaviour. Transmembrane potential maps and phase singularity traces are analysed to determine effects on spiral wave behaviour. Results demonstrate that the prolonged refractoriness of the crista terminalis (CT) affects the pattern of spiral wave reentry, while the variation in action potential morphology of the other structures does not. The CT anchors the spiral waves, preventing them from drifting away. Spiral wave dynamics is altered when the ends of the sheet are spliced together to form a cylinder. The main effect of the continuous surface is the generation of secondary spiral waves which influences the primary rotors. The interaction of the primary and secondary spiral waves decreased as cylinder diameter increased.
Collapse
|
26
|
Oliver RA, Henriquez CS, Krassowska W. Bistability and correlation with arrhythmogenesis in a model of the right atrium. Ann Biomed Eng 2005; 33:577-89. [PMID: 15981859 DOI: 10.1007/s10439-005-1473-z] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
Abstract
Rapid pacing is an important tool for understanding cardiac arrhythmias. A recent experiment involving rapid pacing of sheep atria indicated that the initiation of atrial arrhythmias may be related to the 1:1/2:1 bistability. To elucidate the mechanism of this relation, this study applied the pacing protocol from the sheep study to an idealized model of the right atrium. The model included all major anatomical features, the sino-atrial node, and the regional differences in the action potential duration (APD). A pacing protocol was applied, in which the basic cycle length (BCL) was decreased in steps of 10 ms until the response switched to 2:1, then BCL was increased. The 1:1-to-2:1 transitions occurred at shorter BCLs than the 2:1-to-1:1 transitions yielding a global bistability window of 60ms. As in the sheep study, idiopathic waves were observed at BCLs within or near the bistability window. The model was used to quantify the types, prevalence, and persistence of idiopatic waves, study their initiation and termination, and relate them to the model components. The results demonstrate that idiopatic waveforms move with the shift of the bistability window and that they disappear when bistability is eliminated. Thus, this modeling study supports causal relationship between the 1:1/2:1 bistability and the initiation of arrhythmias.
Collapse
Affiliation(s)
- Robert A Oliver
- Department of Biomedical Engineering, Duke University, PO Box 90281, Durham, NC 27708, USA.
| | | | | |
Collapse
|
27
|
Khau Van Kien P, Wolf JE, Mathieu F, Zhu L, Salve N, Lalande A, Bonnet C, Lesca G, Plauchu H, Dellinger A, Nivelon-Chevallier A, Brunotte F, Jeunemaitre X. Familial thoracic aortic aneurysm/dissection with patent ductus arteriosus: genetic arguments for a particular pathophysiological entity. Eur J Hum Genet 2004; 12:173-80. [PMID: 14722581 DOI: 10.1038/sj.ejhg.5201119] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Thoracic aortic aneurysm and aortic dissection (TAA and AD) are an important cause of sudden death. Familial cases could account for 20% of all cases. A genetic heterogeneity with two identified genes (FBN1 and COL3A1) and three loci (3p24-25 or MFS2/TAAD2, 5q13-q14 and 11q23.2-24) has been shown previously. Study of a single family composed of 179 members with an abnormally high occurrence of TAA/AD disease. A total of 40 subjects from three generations were investigated. In addition to five cases of stroke and three cases of sudden death, there were four cases of AD and four cases of TAA in adults. In all, 11 cases of patent ductus arteriosus (PDA) were observed, two of which were associated with TAA and one with AD. Segregation analysis showed that the distribution of these vascular abnormalities was more likely compatible with a single genetic defect with an autosomal dominant pattern of inheritance. There were no clinical signs of Marfan, Elhers-Danlos vascular type or Char syndromes. Genetic linkage analysis was performed for seven genes or loci implicated in familial TAA/AD disease (COL3A1, FBN1, 3p24-25 or MFS2/TAAD2, 5q13-q14 and 11q23.2-q24), Char syndrome (TFAP2B) or autosomal recessive PDA (12q24). Using different genetic models, linkage with these seven loci was excluded. Familial TAA/AD with PDA is likely to be a particular heritable vascular disorder, with an as yet undiscovered Mendelian genetic basis.
Collapse
Affiliation(s)
- Philippe Khau Van Kien
- INSERM U36, Collège de France, and Département de Génétique, Hôpital Européen Georges Pompidou, Paris, France.
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
28
|
Aronson S, Heller L. Transesophageal Echocardiography and Evaluation of Valvular Heart Disease. Int Anesthesiol Clin 2004; 42:83-96. [PMID: 14716198 DOI: 10.1097/00004311-200404210-00007] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
Affiliation(s)
- Solomon Aronson
- University of Chicago Hospital and Clinics, Chicago, IL 60617, USA.
| | | |
Collapse
|
29
|
Reference values for left ventricular function in subjects under general anaesthesia and controlled ventilation assessed by two-dimensional transoesophageal echocardiography. Eur J Anaesthesiol 2001. [DOI: 10.1097/00003643-200111000-00003] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
30
|
Miller JP, Lambert AS, Shapiro WA, Russell IA, Schiller NB, Cahalan MK. The adequacy of basic intraoperative transesophageal echocardiography performed by experienced anesthesiologists. Anesth Analg 2001; 92:1103-10. [PMID: 11323329 DOI: 10.1097/00000539-200105000-00005] [Citation(s) in RCA: 44] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
UNLABELLED Transesophageal echocardiography (TEE) may improve intraoperative decision-making and patient outcome if it is performed and interpreted correctly. After revising our TEE examination to fulfill the published guidelines for basic TEE practitioners, we prospectively evaluated the ability of our cardiac anesthesiologists (all very experienced with TEE) to record and interpret this revised examination. Educational aids and regular TEE performance feedback were provided to the anesthesiologists. Their interpretations were compared with the independently determined results of experts. Compared with their own historical controls (42% recording rate), all anesthesiologists showed significant improvement in their ability to record a basic intraoperative TEE examination resulting in 81% (P < 0.0001) of all required images being recorded: 88% before cardiopulmonary bypass, 77% immediately after bypass, and 64% after chest closure. Seventy-nine percent of the images recorded at baseline were correctly interpreted, 6% were incorrectly interpreted, and 15% were not evaluated. Our attempt to assess compliance with published guidelines for basic intraoperative TEE resulted in a marked improvement in our intraoperative TEE practice. Most, but not all, standard cross-sections are recorded or interpreted correctly, even by highly experienced and motivated practitioners. IMPLICATIONS Experienced cardiac anesthesiologists can obtain and correctly interpret most basic intraoperative transesophageal echocardiograms.
Collapse
Affiliation(s)
- J P Miller
- Department of Anesthesia and Operative Services, Madigan Army Medical Center, Tacoma, WA 98431, USA.
| | | | | | | | | | | |
Collapse
|
31
|
Abstract
Although considerable progress has been made in understanding the process of wavefront propagation and arrhythmogenesis in human atria, technical concerns and issues of patient safety have limited experimental investigations. The present work describes a finite volume-based computer model of human atrial activation and current flow to complement these studies. Unlike previous representations, the model is three-dimensional, incorporating both the left and right atria and the major muscle bundles of the atria, including the crista terminalis, pectinate muscles, limbus of the fossa ovalis, and Bachmann's bundle. The bundles are represented as anisotropic structures with fiber directions aligned with the bundle axes. Conductivities are assigned to the model to give realistic local conduction velocities within the bundles and bulk tissue. Results from simulations demonstrate the role of the bundles in a normal sinus rhythm and also reveal the patterns of activation in the septum, where experimental mapping has been extremely challenging. To validate the model, the simulated normal activation sequence and conduction velocities at various locations are compared with experimental observations and data. The model is also used to investigate paced activation, and a mechanism of the relative lengthening of left versus right stimulation is presented. Owing to both the realistic geometry and the bundle structures, the model can be used for further analysis of the normal activation sequence and to examine abnormal conduction, including flutter. The full text of this article is available at http://www.circresaha.org.
Collapse
Affiliation(s)
- D Harrild
- Department of Biomedical Engineering, Duke University, Durham, NC 27708-0281, USA
| | | |
Collapse
|
32
|
Suriani RJ, Neustein S, Shore-Lesserson L, Konstadt S. Intraoperative transesophageal echocardiography during noncardiac surgery. J Cardiothorac Vasc Anesth 1998; 12:274-80. [PMID: 9636907 DOI: 10.1016/s1053-0770(98)90005-2] [Citation(s) in RCA: 75] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
OBJECTIVE To investigate the use and impact of transesophageal echocardiography (TEE) during noncardiac surgery. DESIGN Retrospective study. SETTING A university teaching hospital. PARTICIPANTS AND INTERVENTIONS The medical records and the videotapes of 123 intraoperative TEE examinations were reviewed. MEASUREMENTS AND MAIN RESULTS TEE was used for non-consultative indications in 68 patients and in consultation in 55 patients. Information that would not have been detected intraoperatively by other means included intracardiac defects, valvular and aortic pathology, the presence or absence of ventricular dysfunction or intracardiac thrombi, and embolization during surgery. Findings during the initial TEE examination and the TEE evaluation of intraoperative events resulted in a major impact on patient management in 15% of patients. The majority of patients in whom TEE had any impact (the sum of major, minor, and limited impact groups) were classified as American Society of Anesthesiologists (ASA) class 3 or 4. Patients in whom TEE had any impact were significantly older than patients in whom TEE had no impact (66.5 +/- 13.4 years v 58.1 +/- 16.2 years; p < 0.05). No patient experienced a complication related to intraoperative TEE. CONCLUSION It appears that TEE in patients undergoing noncardiac surgery is efficacious in rapidly disclosing new findings and information during periods of hemodynamic instability. It may have a significant impact on intraoperative patient management and may be beneficial in patients older than 66 years of age.
Collapse
Affiliation(s)
- R J Suriani
- Department of Anesthesiology, Mount Sinai Medical Center, New York, NY, USA
| | | | | | | |
Collapse
|
33
|
Suriani RJ, Abel M. Acute superior vena cava syndrome resulting from inferior vena cava cross-clamping. J Cardiothorac Vasc Anesth 1997; 11:197-200. [PMID: 9105994 DOI: 10.1016/s1053-0770(97)90215-9] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Affiliation(s)
- R J Suriani
- Department of Anesthesiology, Mount Sinai Medical Center, New York, NY, USA
| | | |
Collapse
|
34
|
Abstract
This article presents an overview of the benefits and efficacy of transesophageal echocardiography (TEE) in the critically ill patient. The echocardiographic evaluation of ventricular function both regional and global, is discussed with special emphasis on ischemic heart disease; assessment of preload, interrogation of valvular heart disease (prosthetic and native) and its complications; endocarditis and its complications; intracardiac and extracardiac masses, including pulmonary embolism; aortic diseases (e.g., aneurysan, dissection, and traumatic tears); evaluation of patent foramen ovale and its association with central and peripheral embolic events; advancements in computer technology; and finally, the effect of TEE on critical care.
Collapse
Affiliation(s)
- D T Porembka
- Department of Anesthesia, University of Cincinnati College of Medicińe, Ohio, USA
| |
Collapse
|
35
|
Armstrong WF, Bach DS, Carey L, Chen T, Donovan C, Falcone RA, Marcovitz PA. Spectrum of acute dissection of the ascending aorta: a transesophageal echocardiographic study. J Am Soc Echocardiogr 1996; 9:646-56. [PMID: 8887867 DOI: 10.1016/s0894-7317(96)90060-7] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
Transesophageal echocardiography is an accurate tool for the immediate diagnosis of acute aortic dissection. In addition to establishing the diagnosis of dissection, transesophageal echocardiography provides determination of its extent and detection of complications. The purpose of this study was to delineate the full spectrum of abnormalities present in acute dissection of the ascending aorta as assessed by transesophageal echocardiography. Forty consecutive patients with acute ascending aortic dissection were evaluated. Specific attention was paid to complications of aortic valve insufficiency, pericardial effusion, and left ventricular wall motion abnormalities. The aortic arch and the descending aorta were also evaluated for involvement. Quantitative data included measurement of the aorta at the anulus, sinuses, and tubular portion, as well as the proximal and distal descending aortas. An intimal flap was identified in all patients. This was a simple linear tear in 22 patients (55%) and circumferential in eight (20%). A complex tear was noted in 10 patients (25%). The majority of patients (n = 30; 75%) had extension of the dissection into the descending thoracic aorta. At least one communication between the true and false lumens ("entrance point") was identified in 31 patients (78%). Pericardial effusions were noted in 19 patients (48%), only two of whom had a moderate-size effusion. Moderate or severe aortic insufficiency was seen in 18 patients (45%) and regional wall motion abnormalities in six patients. We conclude that acute dissection of the ascending aorta results in a complex or convoluted flap rather than a simple linear tear in many patients. The complication of clinically significant pericardial effusion was rare. Aortic insufficiency is common and can be attributed to multiple mechanisms.
Collapse
Affiliation(s)
- W F Armstrong
- Department of Internal Medicine, University of Michigan, USA
| | | | | | | | | | | | | |
Collapse
|
36
|
Manning WJ, Silverman DI. Atrial anatomy and function postcardioversion: insights from transthoracic and transesophageal echocardiography. Prog Cardiovasc Dis 1996; 39:33-46. [PMID: 8693094 DOI: 10.1016/s0033-0620(96)80039-9] [Citation(s) in RCA: 21] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
Echocardiography provides a valuable tool for the evaluation and assessment of atrial function in patients with atrial fibrilation (AF). Atrial morphology after restoration of sinus rhythm is dynamic, with a decrease in atrial size if sinus rhythm is maintained and atrial growth among those with sustained AF. Restoration of electrocardiographic sinus rhythm is frequently accompanied by relatively depressed atrial mechanical function, with recovery that appears to be related to multiple factors, including the duration of AF before cardioversion and the mode of cardioversion. Such delay appears to confer ongoing risk for thrombus formation and thromboembolism in the days after cardioversion and argues strongly for the need to maintain therapeutic anticoagulation during the pericardioversion and postcardioversion period.
Collapse
Affiliation(s)
- W J Manning
- Beth Israel Hospital, Harvard Medical School, Boston, MA, USA
| | | |
Collapse
|
37
|
Abstract
Surgery for valvular heart disease corrects systolic or diastolic dysfunction of the mitral, aortic, or tricuspid valves. The intraoperative echocardiographic assessment of the native heart valve is aimed at defining the pathology of valve disease, determining the mechanism of valve dysfunction, and quantitating the degree (grade) of valvular stenosis or insufficiency.
Collapse
Affiliation(s)
- J S Savino
- Department of Anesthesia, University of Pennsylvania Medical Center, Philadelphia, USA
| |
Collapse
|