1
|
Gaibazzi N, Davies J, Tuttolomondo D, Pontone G, Guaricci AI, Lorenzoni V, Benatti G, Siniscalchi C, Pastorini G. Association of coronary artery Doppler-echocardiography diastolic-systolic velocity ratio at rest with obstructive coronary artery stenosis on the left main or left anterior descending coronary artery. Int J Cardiol 2019; 281:1-7. [PMID: 30739803 DOI: 10.1016/j.ijcard.2019.01.104] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/24/2018] [Revised: 01/07/2019] [Accepted: 01/30/2019] [Indexed: 12/18/2022]
Abstract
BACKGROUND We assessed whether the non-invasive measure of peak diastolic-systolic velocity ratio (rDSVR) at rest on the left anterior descending artery (LAD) using Doppler transthoracic echocardiography is associated with obstructive coronary artery disease (CAD) on the LAD and left main (LM) arteries. We compared rDSVR diagnostic accuracy with stress wall motion (WM) and coronary flow reserve (CFR-LAD), in a group of subjects who underwent contrast stress-echocardiography (cSE) and coronary angiography within 3 months. METHODS 286 patients selected with a clinical indication to cSE, in which CFR-LAD was measured during the test who also underwent coronary angiography within 3 months were selected and diagnostic performance compared. RESULTS Demographics and clinical variables were univariate predictors of LAD or LM >50% stenosis, but rDSVR < 1.7 outperformed other variables (OR 11.18, 95% CI 5.82-21.49, p < 0.001), comprising cSE variables such as reversible WM abnormalities (OR 1.53, 95% CI 0.94-2.49, p = 0.087) or CFR-LAD < 2 (OR 2.88, 95% CI 21.74-4.77, p < 0.001). The addition of rDSVR to multivariate logistic regression models (clinical or clinical + cSE variables) led to a marked increase in C-index (0.82, 95%CI 0.78-0.87) with significant improvement compared to all prior models (p < 0.001). CONCLUSIONS Our data suggest a strict association of reduced rDSVR with >50% coronary artery stenosis on the LM/LAD, superior to other standard clinical or cSE related indexes, such as WM assessment or CFR-LAD, and builds incrementally to them and clinical variables in multivariable logistic models for the prediction of CAD on LM and LAD coronaries.
Collapse
Affiliation(s)
- Nicola Gaibazzi
- Parma University Hospital, Via Gramsci 14, 43123 Parma, Italy.
| | | | | | | | | | | | - Giorgio Benatti
- Parma University Hospital, Via Gramsci 14, 43123 Parma, Italy
| | | | - Guido Pastorini
- Parma University Hospital, Via Gramsci 14, 43123 Parma, Italy
| |
Collapse
|
2
|
Holte E, Vegsundvåg J, Hegbom K, Hole T, Wiseth R. Transthoracic Doppler Echocardiography for Detection of Stenoses in the Left Coronary Artery by Use of Poststenotic Coronary Flow Profiles: A Comparison with Quantitative Coronary Angiography and Coronary Flow Reserve. J Am Soc Echocardiogr 2013; 26:77-85. [DOI: 10.1016/j.echo.2012.10.001] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/08/2012] [Indexed: 10/27/2022]
|
3
|
KOSKENVUO JW, SARASTE M, NIEMI P, KNUUTI J, SAKUMA H, TOIKKA JO, KOMU M, JA¨RVISALO MJ, HARTIALA JJ. Correlation of transthoracic Doppler echocardiography and magnetic resonance imaging in measuring left anterior descending artery flow velocity and time‐course of dipyridamole‐induced coronary flow increase. Scandinavian Journal of Clinical and Laboratory Investigation 2009. [DOI: 10.1080/00365510310000501-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
4
|
Accadia M, Ascione L, De Michele M, D'Andrea A, Rumolo S, Sacra C, Scherillo M, Tuccillo B. Ultrasonographic assessment of basal coronary flow as a screening tool to exclude significant left anterior descending coronary artery stenosis. J Cardiovasc Med (Hagerstown) 2006; 7:696-700. [PMID: 16932084 DOI: 10.2459/01.jcm.0000243004.13041.67] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
OBJECTIVE Coronary blood flow exhibits a biphasic pattern at rest with a higher diastolic and a smaller systolic component. In the present investigation, we evaluated whether a decreased diastolic to systolic velocity ratio of basal coronary flow may be useful in the identification of subjects with significant left anterior descending coronary artery (LAD) stenosis. METHODS One hundred and twenty-nine consecutive patients (62 with unstable angina, 25 with acute myocardial infarction and 42 with chronic coronary artery disease) were included in the study. Blood flow velocities were recorded in the mid-distal portion of the LAD using an ATL 5000 CV HDI ultrasound system. All patients underwent coronary angiography and were divided into two groups according to the absence (group 1) or the presence (group 2) of significant LAD stenosis (lumen narrowing > or = 70%). In 60 of the 129 patients, coronary flow reserve was evaluated non-invasively. RESULTS Adequate Doppler recordings in the LAD were obtained by transthoracic echocardiography in 113 patients. There were no differences between groups with regard to sex, cardiovascular risk factors, left ventricular mass and volumes, ejection fraction, whereas the diastolic to systolic velocity ratio of basal coronary flow was significantly lower in group 2 patients (1.41 +/- 4.7 vs. 2.08 +/- 0.64, P < 0.00001). The receiver operating characteristic curve showed that a diastolic to systolic velocity ratio < 1.6 had a sensitivity of 77%, a specificity of 91%, a positive predictive value of 77%, a negative predictive value of 97%, and a diagnostic accuracy of 84% for the presence of significant LAD stenosis. In 55/60 patients, results of basal coronary flow and coronary flow reserve were concordant. On multivariate logistic regression analysis, the diastolic to systolic velocity ratio was a strong independent predictor of LAD stenosis > or = 70% (odds ratio 4.90, 95% confidence interval 1.65-7.30). CONCLUSIONS The present findings suggest that assessment of basal coronary flow in the LAD may be useful to rule out the presence of significant stenosis.
Collapse
Affiliation(s)
- Maria Accadia
- Division of Cardiology, S Maria di Loreto Hospital, Naples, Italy
| | | | | | | | | | | | | | | |
Collapse
|
5
|
Daimon M, Watanabe H, Yamagishi H, Kuwabara Y, Hasegawa R, Toyoda T, Yoshida K, Yoshikawa J, Komuro I. Physiologic Assessment of Coronary Artery Stenosis without Stress Tests: Noninvasive Analysis of Phasic Flow Characteristics by Transthoracic Doppler Echocardiography. J Am Soc Echocardiogr 2005; 18:949-55. [PMID: 16153520 DOI: 10.1016/j.echo.2005.01.006] [Citation(s) in RCA: 13] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/05/2004] [Indexed: 10/25/2022]
Abstract
We evaluated the significance of the diastolic-to-systolic blood flow velocity ratio (DSVR) determined by transthoracic Doppler echocardiography, for a physiologic assessment of the severity of coronary stenosis without stress tests, as compared with thallium 201 single photon emission computed tomography. In 95 patients undergoing thallium 201 single photon emission computed tomography for coronary artery disease, the flow velocity in the distal left anterior descending coronary artery was obtained with transthoracic Doppler echocardiography. The mean and peak DSVR values were calculated using mean and peak coronary flow velocity. DSVR was successfully measured for 82 patients (86.3%), including 33 patients with reversible perfusion defects in the left anterior descending coronary artery territories. For predicting reversible perfusion defects in thallium 201 single photon emission computed tomography, the best cut-off points were 1.5 for mean DSVR (sensitivity 81.8%, specificity 85.7%) and 1.6 for peak DSVR (sensitivity 75.7%, specificity 83.6%). Noninvasive measurement of DSVR with transthoracic Doppler echocardiography provides physiologic estimation of the left anterior descending coronary artery stenosis severity at high success rate, without stress tests.
Collapse
Affiliation(s)
- Masao Daimon
- Department of Cardiovascular Science and Medicine, Chiba University, Graduate School of Medicine, Chiba, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
6
|
Abstract
Transthoracic Doppler echocardiography is emerging as a promising method for evaluating coronary artery disease. After a period of training, detection and measurement of distal left anterior descending coronary artery flow with transthoracic Doppler echocardiography is feasible in more than 90% of the patients. Using transthoracic Doppler echocardiography with a high-frequency transducer and special setting of low Nyquist limits, pathologic coronary flow dynamics can be demonstrated. Measurement of coronary flow reserve may impact diagnosis or clinical treatment in those: (1) with anginal chest pain and angiographically normal coronary arteries; (2) with intermediate-grade coronary obstruction where the physiologic significance is in doubt; and (3) who have had an attempt at revascularization and the effectiveness of the therapy is uncertain.
Collapse
Affiliation(s)
- Ho-Joong Youn
- Division of Cardiology, Department of Internal Medicine, College of Medicine, the Catholic University of Korea, No. 62 Yoido-dong, Youngdungpoku, St. Mary's Hospital, Seoul 150-713, Korea.
| | | |
Collapse
|
7
|
Yoshitatsu M, Miyamoto Y, Mitsuno M, Toda K, Yoshikawa M, Fukui S, Nomura F, Hirata N, Onishi K. Changes in left anterior descending coronary artery flow profiles after coronary artery bypass grafting examined by means of transthoracic Doppler echocardiography. J Thorac Cardiovasc Surg 2004; 126:1531-6. [PMID: 14666029 DOI: 10.1016/s0022-5223(03)00972-3] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/26/2022]
Abstract
OBJECTIVE We sought to investigate the changes of velocity profiles in the left anterior descending coronary artery after coronary artery bypass grafting using transthoracic Doppler echocardiography. METHODS Forty-five patients who received a bypass graft to the left anterior descending coronary artery were studied. Before coronary artery bypass grafting, Doppler velocity profiles of the distal left anterior descending coronary artery were recorded with transthoracic Doppler echocardiography. Peak systolic velocity, mean systolic velocity, peak diastolic velocity, mean diastolic velocity, total velocity time integral, systolic velocity time integral, and diastolic velocity time integral were measured. Three weeks after coronary artery bypass grafting, left anterior descending coronary artery antegrade flow in the distal portion of the anastomosis was obtained by using the same method. Coronary angiography was performed before and 3 weeks after coronary artery bypass grafting. RESULTS The overall success rate of measuring the left anterior descending coronary artery flow was 60.0% preoperatively and 80.0% postoperatively. In 25 patients, in whom all parameters were obtained both before and after coronary artery bypass grafting, the following increased significantly after coronary artery bypass grafting: peak systolic velocity (14.86 +/- 7.50 vs 25.07 +/- 17.02 cm/s, P =.0045), mean systolic velocity (9.86 +/- 5.42 vs 18.03 +/- 12.94 cm/s, P =.0026), peak diastolic velocity (24.26 +/- 12.54 vs 48.28 +/- 31.66 cm/s, P =.0021), mean diastolic velocity (14.94 +/- 6.65 vs 30.36 +/- 20.71 cm/s, P =.0022), diastolic velocity time integral (7.22 +/- 2.88 vs 15.55 +/- 10.39 cm, P =.0009), total velocity time integral (10.50 +/- 4.48 vs 19.27 +/- 12.63 cm, P =.0034), and diastolic-to-systolic velocity time integral ratio (3.09 +/- 1.53 vs 4.97 +/- 2.75, P =.0044). Angiography showed graft patency and no significant change in left anterior descending coronary artery stenosis in all patients. CONCLUSIONS Transthoracic Doppler echocardiography showed a significant increase in some parameters in left anterior descending coronary artery flow after coronary artery bypass grafting. Measurement of left anterior descending coronary artery flow by means of transthoracic Doppler echocardiography might be a noninvasive method to evaluate the effect of bypass grafting on the left anterior descending coronary artery.
Collapse
Affiliation(s)
- Masao Yoshitatsu
- Division of Cardiothoracic Surgery, Sakurabashi-Watanabe Hospital, Osaka, Japan.
| | | | | | | | | | | | | | | | | |
Collapse
|
8
|
Higashiue S, Watanabe H, Yokoi Y, Takeuchi K, Yoshikawa J. Simple detection of severe coronary stenosis using transthoracic doppler echocardiography at rest. Am J Cardiol 2001; 87:1064-8. [PMID: 11348603 DOI: 10.1016/s0002-9149(01)01462-x] [Citation(s) in RCA: 20] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
Abstract
Coronary flow velocity can be measured by transthoracic Doppler echocardiography (TTDE). The purpose of this study was to detect severe coronary stenosis using the diastolic-to-systolic flow velocity ratio (DSVR) determined by TTDE at rest. We prospectively examined 190 consecutive patients with angina pectoris for whom coronary angiography was planned. Doppler spectral tracings of flow velocity in the distal left anterior descending artery were recorded by TTDE at rest. The mean and peak DSVR values were computed using mean and peak coronary flow velocities. DSVR measurement by TTDE at rest was performed within 24 hours before angiography, and in patients who underwent coronary intervention it was performed again within 48 hours after the intervention. The success rate for DSVR measurement by TTDE was 83.7%. There were significant differences in peak DSVR and mean DSVR between the patients with severe stenosis (percent diameter stenosis >85%) and those without severe stenosis (1.3 +/- 0.4 vs 1.9 +/- 0.50 and 1.2 +/- 0.4 vs 1.8 +/- 0.5, respectively; p <0.0001). In the 17 patients with successful intervention, DSVR was significantly increased after the procedure (mean 1.2 +/- 0.1 vs 2.0 +/- 0.2; peak 1.2 +/- 0.2 vs 2.0 +/- 0.3, respectively; p <0.0001). For percent diameter stenosis >85%, the best cut-off points were 1.6 for peak DSVR (sensitivity 79.0%, specificity 75.7%) and 1.5 for mean DSVR (sensitivity 77.0%, specificity 77.9%). Thus, DSVR measurement by TTDE is a simple, noninvasive method for detection of severe coronary stenosis at rest.
Collapse
Affiliation(s)
- S Higashiue
- Division of Cardiovascular Surgery, Kishiwada Tokusyukai Hospital, Kishiwada, Japan
| | | | | | | | | |
Collapse
|
9
|
Moya Mur JL, Guzmán G, Catalán P, Megías A, Ruiz S, Barrios V, Ortega J, de Pablo C, Harriague C, García Lledó A, Asín Cardiel E. [Yield of transthoracic echocardiography with high frequency transducer in the study of the anterior descending coronary artery]. Rev Esp Cardiol 2001; 54:16-21. [PMID: 11141450 DOI: 10.1016/s0300-8932(01)76259-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
INTRODUCTION AND OBJECTIVES This study was performed to evaluate the feasibility and utility of a transthoracic high frequency transducer to detect and measure the left anterior descending coronary artery flow in patients with lesions in this artery or anterior myocardial infarction. MATERIALS AND METHODS We studied 11 subjects with lesions greater than 75% and another 10 with anterior myocardial infarction. We compared the results with a control group of 18 subjects. An ATL HDI 5000 ultrasound unit with a 5-8 MHz transducer was used to identify the left anterior descending in the anterior interventricular sulcus from an apical four chamber window. We considered that left anterior descending was detected when a diastolic predominant flow pattern was obtained with pulse Doppler. RESULTS Left anterior descending was detected in 37/39 of cases (94.4%). Patients with coronary lesions showed a decrease in the limit of significance in the diastolic/systolic peak velocity ratios: 2.5 (SD 0.7) vs 1.8 (SD 0.3) with a p = 0.024. Patients with anterior myocardial infarction obtained lower diastolic/systolic peak velocity ratios than controls: 2.5 (SD 0.7) vs 1.4 (SD 0.3) with a p = 0.001. CONCLUSIONS Left anterior descending coronary artery flow can be assessed by transthoracic high frequency echocardiography in greater than 90% of the cases. Patients with coronary lesions and those with anterior myocardial infarction have a decreased diastolic/systolic peak velocity ratio.
Collapse
Affiliation(s)
- J L Moya Mur
- Instituto de Cardiología. Hospital Ramón y Cajal. Madrid.
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Krzanowski M, Bodzoń W, Brzostek T, Nizankowski R, Szczeklik A. Value of transthoracic echocardiography for the detection of high-grade coronary artery stenosis: prospective evaluation in 50 consecutive patients scheduled for coronary angiography. J Am Soc Echocardiogr 2000; 13:1091-9. [PMID: 11119277 DOI: 10.1067/mje.2000.108130] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
We prospectively evaluated the feasibility of direct, transthoracic evaluation of coronary arteries to diagnose flow-limiting lesions. Second harmonic mode in B-mode and fundamental mode for Doppler examinations was used. A stenosis was diagnosed when maximal flow velocity at least doubled in comparison with that of the adjacent segment or when local velocity was at least 2 m/s. Of the left anterior descending coronary artery segments assessed, 34 were proximal, 35 middle, and 34 distal segments. The corresponding figures for circumflex coronary artery segments were 17 proximal and 11 middle segments and for the right coronary artery, 14 proximal and 15 distal segments. No distal circumflex and only 1 mid right coronary artery segment was visualized. Twenty-eight stenoses were diagnosed. Specificity for stenosis detection was 96% to 100% and sensitivity was 62% to 66%. Echo-cardiography was unable to document occlusions. Transthoracic echocardiography allows for coronary artery assessment in a significant portion of patients scheduled for coronary angiography. It may be used to document the presence of coronary artery stenosis. With further technologic improvements, transthoracic echocardiography could enable the monitoring of the restenosis process after percutaneous transluminal coronary angioplasty/stent intervention and coronary artery luminal narrowing after heart transplantation.
Collapse
Affiliation(s)
- M Krzanowski
- Department of Medicine, Jagiellonian University School of Medicine, 8, Skawińska Str, Kraków, Poland.
| | | | | | | | | |
Collapse
|
11
|
Hildick-Smith DJ, Johnson PJ, Wisbey CR, Winter EM, Shapiro LM. Coronary flow reserve is supranormal in endurance athletes: an adenosine transthoracic echocardiographic study. Heart 2000; 84:383-9. [PMID: 10995406 PMCID: PMC1729440 DOI: 10.1136/heart.84.4.383] [Citation(s) in RCA: 53] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
OBJECTIVE To compare coronary flow reserve in endurance athletes and healthy sedentary controls, using adenosine transthoracic echocardiography. METHODS 29 male endurance athletes (mean (SD) age 27.3 (6.6) years, body mass index (BMI) 22.1 (1.9) kg/m(2)) and 23 male controls (age 27.2 (6.1) years, BMI 23.9 (2.6) kg/m(2)) with no coronary risk factors underwent transthoracic echocardiographic assessment of distal left anterior descending coronary artery (LAD) diameter and flow, both at rest and during intravenous adenosine infusion (140 microg/kg/min). RESULTS Distal LAD diameter and flow were adequately assessed in 19 controls (83%) and 26 athletes (90%). Distal LAD diameter in athletes (2.04 (0.25) mm) was not significantly greater than in sedentary controls (1.97 (0.27) mm). Per cent increase in LAD diameter following 400 microg sublingual nitrate was greater in the athletes than in the controls, at 14.1 (7. 2)% v 8.8 (5.7)% (p < 0.01). Left ventricular mass index in athletes exceeded that of controls, at 130 (19) v 98 (14) g/m(2) (p < 0.01). Resting flow among the athletes (10.6 (3.1) ml/min; 4.4 (1.2) ml/min/100 g left ventricular mass) was less than in the controls (14.3 (3.6) ml/min; 8.2 (2.2) ml/min/100 g left ventricular mass) (both p < 0.01). Hyperaemic flow among the athletes (61.9 (17.8) ml/min) exceeded that of the controls (51.1 (14.6) ml/min; p = 0.02), but not when corrected for left ventricular mass (25.9 (5.6) v 28.5 (7.4) ml/min/100 g left ventricular mass; NS). Coronary flow reserve was therefore substantially greater in the athletes than in the controls, at 5.9 (1.0) v 3.7 (0.7) (p < 0.01). CONCLUSIONS Coronary flow reserve in endurance athletes is supranormal and endothelium independent vasodilatation is enhanced. Myocardial hypertrophy per se does not necessarily impair coronary flow reserve. Adenosine transthoracic echocardiography is a promising technique for the investigation of coronary flow reserve.
Collapse
|
12
|
Mulvagh SL. Myocardial perfusion by contrast echocardiography: diagnosis of coronary artery disease using contrast-enhanced stress echocardiography and assessment of coronary anatomy and flow reserve. Coron Artery Dis 2000; 11:243-51. [PMID: 10832558 DOI: 10.1097/00019501-200005000-00007] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
The advent of intravenous contrast agents, and newer ultrasound technology to enhance their detection, promises to improve and augment our conventional stress echocardiographic practice by improving diagnostic accuracy and providing novel information regarding myocardial perfusion and functional assessment of the coronary vasculature. The combination of intravenous contrast and harmonic stress echocardiography is a powerful tool for improved wall motion analysis through enhanced image quality, routinely permitting the evaluation of patients with suboptimal images. In this era of cost containment, we await studies in large populations addressing resource utilization and cost-effectiveness to determine if, indeed, all patients presenting with stress echocardiography should receive contrast. Myocardial perfusion can be observed using the technique, but the complex interactions of microbubbles and ultrasound in patients must be understood more fully before its implementation becomes routine practice. Non-invasive imaging of coronary arteries using contrast-enhanced transthoracic harmonic echo/Doppler promises to expand the field of diagnostic and experimental echocardiography, bringing new insight into the pathophysiology of ischemic and non-ischemic heart disease. The continued development of newer contrast agents and refinement of ultrasound imaging equipment ensures that the applications of contrast echocardiography in the assessment of CAD will continue to increase.
Collapse
|
13
|
Jureidini SB, Marino CJ, Singh GK, Fiore A, Balfour IC. Main coronary artery and coronary ostial stenosis in children: detection by transthoracic color flow and pulsed Doppler echocardiography. J Am Soc Echocardiogr 2000; 13:255-63. [PMID: 10756242 DOI: 10.1067/mje.2000.102983] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Coronary artery stenosis (CAS) and coronary ostial stenosis (COS) are potentially life-threatening conditions. The echocardiographic diagnosis of CAS and COS in children has not been described. We report on the transthoracic echocardiography (TTE) findings of CAS and COS in children. Six patients, aged 1 week to 12 years, with clinically confirmed COS (n = 5) and CAS (n = l) were diagnosed by TTE. Their echocardiographic findings were compared with 26 healthy control subjects of a similar age range. Left COS was associated with an aberrant left coronary artery (CA) from the contralateral aortic sinus (n = 2), an intramural left CA with d-transposition of the great vessels (n = l), and supravalvular aortic stenosis (n = l). Right COS was present in a patient with aortic valvular stenosis. Acquired left main CAS was diagnosed in the sixth patient 3 years after orthotopic heart transplantation. Coronary ostial stenosis was recognized when a color flow acceleration signal was present proximal to and extending into the coronary ostium (CO). Coronary artery stenosis was detected when a coarctated color flow stream was present within the stenosed CA segment with turbulent distal flow. These findings were not detected in the control cohort who demonstrated laminar CA and CO flow signals. All patients had increased spectral velocity in the CA distal to the stenosed segment (patients = 50 +/- 5 cm/s, controls = 24 +/- 6 cm/sec; P <.01). Delayed peak diastolic velocity seemed to indicate severe stenosis. We conclude that (1) CO acceleration signals and turbulent coarctated CA flow signals are abnormal findings in TTE coronary Doppler assessment. They indicate COS and CAS, respectively. (2) Knowledge of the normal TTE CA flow velocity patterns is essential so that abnormal velocity signals such as seen with CAS and COS can be recognized and a timely diagnosis made.
Collapse
Affiliation(s)
- S B Jureidini
- Department of Pediatrics, Saint Louis University School of Medicine, St Louis, MO, USA
| | | | | | | | | |
Collapse
|
14
|
Kuriki S, Nasu M, Fukami Ki KI, Hiramori K. Noninvasive Measurement of Left Coronary Blood Flow Reserve by Transthoracic Doppler Echocardiography: Comparison with Doppler Guidewire Ultrasonography. Echocardiography 1999; 16:547-557. [PMID: 11175187 DOI: 10.1111/j.1540-8175.1999.tb00103.x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
The development of new ultrasound instrumentation has made epicardial coronary artery blood flow imaging easier with the use of transthoracic coronary Doppler echocardiography (TCDE). This study was performed to investigate the accuracy of coronary blood flow reserve (CFR) measurement by TCDE. In 15 patients with ischemic heart disease in the absence of valvular disease or atrial fibrillation, coronary flow at rest and flow with hyperemia induced by intravenous dipyridamole infusion were recorded by TCDE and Doppler guidewire ultrasonography. The CFR was determined as the ratio of the maximum hyperemic diastolic time-averaged peak velocity to the velocity at rest in the proximal or distal left anterior descending coronary artery. It was found that the CFR of the left anterior descending coronary artery measured by TCDE was comparable in accuracy with CFR measured by invasive methods (r = 0.87, P < 0.0001, n = 15).
Collapse
Affiliation(s)
- Satoshi Kuriki
- The Second Department of the Iwate Medical University, 19-1 Uchimaru Morioka, 020-0021, Japan
| | | | | | | |
Collapse
|