• Reference Citation Analysis
  • v
  • v
  • Find an Article
Find an Article PDF (4593696)   Today's Articles (1658)   Subscriber (49324)
For: Shin JH, Lee JS, Choi SH, Lee DK, Nam H, Cha GS. A planar pCO2 sensor with enhanced electrochemical properties. Anal Chem 2000;72:4468-73. [PMID: 11008785 DOI: 10.1021/ac000427o] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [What about the content of this article? (0)] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Number Cited by Other Article(s)
1
Dervieux E, Théron M, Uhring W. Carbon Dioxide Sensing-Biomedical Applications to Human Subjects. SENSORS (BASEL, SWITZERLAND) 2021;22:188. [PMID: 35009731 PMCID: PMC8749784 DOI: 10.3390/s22010188] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 12/13/2021] [Accepted: 12/20/2021] [Indexed: 02/06/2023]
2
Developments in marine pCO2 measurement technology; towards sustained in situ observations. Trends Analyt Chem 2017. [DOI: 10.1016/j.trac.2016.12.008] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
3
Imtaiyaz Hassan M, Shajee B, Waheed A, Ahmad F, Sly WS. Structure, function and applications of carbonic anhydrase isozymes. Bioorg Med Chem 2012;21:1570-82. [PMID: 22607884 DOI: 10.1016/j.bmc.2012.04.044] [Citation(s) in RCA: 160] [Impact Index Per Article: 13.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2012] [Revised: 04/02/2012] [Accepted: 04/21/2012] [Indexed: 01/16/2023]
4
Kwon NH, Lee KS, Won MS, Shim YB. An all-solid-state reference electrode based on the layer-by-layer polymer coating. Analyst 2007;132:906-12. [PMID: 17710266 DOI: 10.1039/b706905g] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
5
Herber S, Bomer J, Olthuis W, Bergveld P, van den Berg A. A Miniaturized Carbon Dioxide Gas Sensor Based on Sensing of pH-Sensitive Hydrogel Swelling with a Pressure Sensor. Biomed Microdevices 2005;7:197-204. [PMID: 16133807 DOI: 10.1007/s10544-005-3026-5] [Citation(s) in RCA: 57] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
6
Kwon NH, Won MS, Park DS, Shim YB. Stability Enhancement of All-Solid-State H+ ISEs with Cross-Linked Silicon-Urethane Matrices. ELECTROANAL 2005. [DOI: 10.1002/elan.200403144] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
7
Bobacka J, Maj-Zurawska M, Lewenstam A. Carbonate ion-selective electrode with reduced interference from salicylate. Biosens Bioelectron 2003;18:245-53. [PMID: 12485771 DOI: 10.1016/s0956-5663(02)00179-3] [Citation(s) in RCA: 15] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
8
Bakker E, Telting-Diaz M. Electrochemical sensors. Anal Chem 2002;74:2781-800. [PMID: 12090665 DOI: 10.1021/ac0202278] [Citation(s) in RCA: 261] [Impact Index Per Article: 11.9] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
PrevPage 1 of 1 1Next
© 2004-2024 Baishideng Publishing Group Inc. All rights reserved. 7041 Koll Center Parkway, Suite 160, Pleasanton, CA 94566, USA