1
|
Qian J, Li H, Wang Y, Li Y, Yu J, Zhou L, Pu Q. Zwitterionic surfactant as an additive for efficient electrophoretic separation of easily absorbed rhodamine dyes on plastic microchips. J Chromatogr A 2023; 1688:463716. [PMID: 36565653 DOI: 10.1016/j.chroma.2022.463716] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2022] [Revised: 12/07/2022] [Accepted: 12/09/2022] [Indexed: 12/15/2022]
Abstract
Plastic microchips possess the advantages of easy fabrication and low-cost, but their surface properties are frequently incompatible with electrophoretic separation without proper surface modification. Meanwhile, the separation microchannels on typical microchips are usually only a few centimeters long, the pressurized flow may significantly affect the electrophoretic separation if their inner diameters (id) are relatively larger (approximately > 50 μm), viscous separation medium is therefore required for efficient separation. Herein, a zwitterionic surfactant, N-hexadecyl-N,N-dimethyl-3-ammonio-1-propane sulfonate (HDAPS), was used as a multifunctional additive to inhibit the analyte adsorption, improve the surface status, control Joule heating and modulate the resolution on cyclic olefin copolymer microchips with 80 μm id, 5 cm long separation microchannels, eliminating the necessity of viscous polymeric additives. The effectiveness of HDAPS was compared with an ionic polymeric additive, poly(diallydimethylammonium chloride). The streaming potential and electroosmotic flow measurements indicated an effective inhibition of the adsorption of rhodamine B and a stable negative surface charge with zwitterionic HDAPS. Using 15 mmol/L HDAPS, 40% (v/v) methanol, and 10 mmol/L boric acid (pH 3.2) as the running buffer, rapid separation of four rhodamines was achieved within 90 s under a separation electric field of 520 V/cm. The theoretical plate numbers were in a range of 5.0×105-6.9×105/m. The relative standard deviations were no more than 0.9% for retention time and 1.5% for peak area. The proposed system was verified by the determination of rhodamines in eyeshadow and wolfberry, with standard recoveries in a range of 98.2%-101.4%.
Collapse
Affiliation(s)
- Jiali Qian
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metals Chemistry and Resources Utilization of Gansu Province, Department of Chemistry, Lanzhou University, Lanzhou, Gansu 730000, China
| | - Hongli Li
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metals Chemistry and Resources Utilization of Gansu Province, Department of Chemistry, Lanzhou University, Lanzhou, Gansu 730000, China
| | - Yuanhang Wang
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metals Chemistry and Resources Utilization of Gansu Province, Department of Chemistry, Lanzhou University, Lanzhou, Gansu 730000, China
| | - Yixuan Li
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metals Chemistry and Resources Utilization of Gansu Province, Department of Chemistry, Lanzhou University, Lanzhou, Gansu 730000, China
| | - Jie Yu
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metals Chemistry and Resources Utilization of Gansu Province, Department of Chemistry, Lanzhou University, Lanzhou, Gansu 730000, China
| | - Lei Zhou
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metals Chemistry and Resources Utilization of Gansu Province, Department of Chemistry, Lanzhou University, Lanzhou, Gansu 730000, China.
| | - Qiaosheng Pu
- State Key Laboratory of Applied Organic Chemistry, Key Laboratory of Nonferrous Metals Chemistry and Resources Utilization of Gansu Province, Department of Chemistry, Lanzhou University, Lanzhou, Gansu 730000, China.
| |
Collapse
|
2
|
Denoroy L, Parrot S. Analysis of Amino Acids and Related Compounds by Capillary Electrophoresis. SEPARATION AND PURIFICATION REVIEWS 2016. [DOI: 10.1080/15422119.2016.1212378] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
3
|
Chung M, Kim D, Herr AE. Polymer sieving matrices in microanalytical electrophoresis. Analyst 2014; 139:5635-54. [DOI: 10.1039/c4an01179a] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
|
4
|
Synthesis and characterization of a novel potato starch derivative with cationic acetylcholine groups. Int J Biol Macromol 2012; 50:701-6. [DOI: 10.1016/j.ijbiomac.2011.12.031] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2011] [Revised: 12/19/2011] [Accepted: 12/24/2011] [Indexed: 11/20/2022]
|
5
|
Liu J, Chen CF, Yang S, Chang CC, Devoe DL. Mixed-mode electrokinetic and chromatographic peptide separations in a microvalve-integrated polymer chip. LAB ON A CHIP 2010; 10:2122-2129. [PMID: 20556309 DOI: 10.1039/c003505j] [Citation(s) in RCA: 22] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/29/2023]
Abstract
A cycloolefin polymer chip supporting the concatenation of isoelectric focusing (IEF) and reversed-phase liquid chromatography (RPLC) is demonstrated for high throughput two dimensional peptide separations. A unique benefit of the mixed-mode platform is the ability of IEF to act as a highly concentrating electrokinetic separation mode for effective isolation of sample components prior to RPLC. The thermoplastic chip contains integrated high pressure microvalves, enabling uniform sample transfer from the IEF channel to multiple parallel RPLC channels, gradient elution from each RPLC column, and hydrodynamic isolation between the separation dimensions. The reusable system is shown to provide efficient 2-D separations together with facile interfacing with MALDI-MS, suggesting a new path towards effective peptide analysis from complex samples.
Collapse
Affiliation(s)
- Jikun Liu
- Department of Mechanical Engineering, University of Maryland, College Park, MD, USA
| | | | | | | | | |
Collapse
|
6
|
Maeda E, Kataoka M, Yatsushiro S, Kajimoto K, Hino M, Kaji N, Tokeshi M, Bando M, Kido JI, Ishikawa M, Shinohara Y, Baba Y. Accurate quantitation of salivary and pancreatic amylase activities in human plasma by microchip electrophoretic separation of the substrates and hydrolysates coupled with immunoinhibition. Electrophoresis 2008; 29:1902-9. [PMID: 18393344 DOI: 10.1002/elps.200700688] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A high-performance determination system for alpha-amylase isoenzyme activities in human plasma involving microchip electrophoresis with a plastic chip was developed. The combination of microchip electrophoresis for substrate and hydrolysate separation and an immunoinhibition method for the differentiation of isoenzyme activities using antihuman salivary amylase (S-AMY) mAb allowed the highly selective determination of amylase isoenzyme (S-AMY and pancreatic amylase (P-AMY)) activities even in a complex matrix such as a crude plasma sample. We used 8-aminopyrene-1,3,6-trisulfonic acid (APTS)-labeled maltohexaose (G6) as a substrate. Amylase in a human plasma sample hydrolyzed APTS-G6 into APTS-maltotriose (G3) and G3, which was measured as the fluorescence intensity of APTS-G3 on microchip electrophoresis. A double logarithm plot revealed a linear relationship between amylase activity and fluorescence intensity in the range of 5-500 U/L of amylase activity (r2=0.9995, p<0.01), and the LOD was 4.38 U/L. Amylase activities in 13 subjects determined by the present method were compared with the results obtained by conventional methods with nitrophenylated oligosaccharides as substrates, respectively. Good correlations were observed for each method on simple linear regression analysis (both p<0.01). The reproducibilities of within-days for total amylase and P-AMY were 2.98-6.27 and 3.83-6.39%, respectively, and these between-days were 2.88-5.66 and 3.64-5.63%, respectively. This system enables us to determine amylase isoenzyme activities in human plasma with high sensitivity and accuracy, and thus will be applicable to clinical diagnosis.
Collapse
Affiliation(s)
- Eiki Maeda
- Department of Molecular and Pharmaceutical Biotechnology, Graduate School of Pharmaceutical Sciences, University of Tokushima, Tokushima, Japan
| | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
7
|
Chen Y, Zhang L, Chen G. Fabrication, modification, and application of poly(methyl methacrylate) microfluidic chips. Electrophoresis 2008; 29:1801-14. [DOI: 10.1002/elps.200700552] [Citation(s) in RCA: 113] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
8
|
Affiliation(s)
- Masaru KATO
- Center for NanoBio Integration, Department of Applied Chemistry, Graduate School of Engineering, The University of Tokyo
| |
Collapse
|
9
|
Li FA, Wang CH, Her GR. A sheathless poly(methyl methacrylate) chip-CE/MS interface fabricated using a wire-assisted epoxy-fixing method. Electrophoresis 2007; 28:1265-73. [PMID: 17366484 DOI: 10.1002/elps.200600552] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Using a wire-assisted epoxy-fixing method, a sheathless CE/MS interface on a poly-(methyl methacrylate) (PMMA) CE chip has been developed. The sheathless chip-CE/MS interface utilized a tapered fused-silica tip and the electrical connection was achieved through a layered coating of conductive rubber. The wire-assisted method provided facile alignment of channels between the PMMA CE chip and an external capillary sprayer without the need for micromachining. Because the wire was in the channel during fixing, the risk of channel blockage by the epoxy was avoided. This chip CE device has minimal dead volume because the interstitial spaces were filled by a fast-fixing epoxy resin. The performance of the chip-CE-ESI-MS device was demonstrated with the analysis of peptide mixtures.
Collapse
Affiliation(s)
- Fu-An Li
- Department of Chemistry, National Taiwan University, Taipei, Taiwan
| | | | | |
Collapse
|
10
|
Sibarani J, Takai M, Ishihara K. Surface modification on microfluidic devices with 2-methacryloyloxyethyl phosphorylcholine polymers for reducing unfavorable protein adsorption. Colloids Surf B Biointerfaces 2007; 54:88-93. [PMID: 17112710 DOI: 10.1016/j.colsurfb.2006.09.024] [Citation(s) in RCA: 151] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/07/2006] [Revised: 09/06/2006] [Accepted: 09/26/2006] [Indexed: 11/19/2022]
Abstract
Surface modification of polymer materials for preparing microfluidic devices including poly(dimethyl siloxane) (PDMS) was investigated with phospholipids polymers such as poly(2-methacryloyloxylethyl phosphorylcholine(MPC)-co-n-butyl methacrylate) (PMB) and poly(MPC-co-2-ethylhexyl methacrylate-co-2-(N,N-dimethylamino)ethyl methacrylate) (PMED). The hydrophilicity of every surface on the polymer materials modified with these MPC polymers increased and the value of zeta-potential became close to zero. The protein adsorption on the polymer materials with and without the surface modification was evaluated using a protein mixture of human plasma fibrinogen and serum albumin. Amount of proteins adsorbed on these polymeric materials showed significant reduction by the surface modification with the MPC polymers compared to the uncoated surfaces ranging from 56 to 90%. Furthermore, we successfully prepared PDMS-based microchannel which was modified by simple coating with the PMB and PMED. The modified microchannel also revealed a significant reduction of adsorption of serum albumin. We conclude that the MPC polymers are useful for reducing unfavorable protein adsorption on microfluidic devices.
Collapse
Affiliation(s)
- James Sibarani
- Department of Materials Engineering and Center for Nanobio Integration, The University of Tokyo, 7-3-1 Hongo, Bunkyo-ku, Tokyo 113-8656, Japan
| | | | | |
Collapse
|
11
|
Naruishi N, Tanaka Y, Higashi T, Wakida SI. Highly efficient dynamic modification of plastic microfluidic devices using proteins in microchip capillary electrophoresis. J Chromatogr A 2006; 1130:169-74. [PMID: 16860810 DOI: 10.1016/j.chroma.2006.07.005] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2006] [Revised: 06/12/2006] [Accepted: 07/04/2006] [Indexed: 12/24/2022]
Abstract
New dynamic coating agents were investigated for the manipulation of electroosmotic flow (EOF) in poly(methylmethacrylate) (PMMA) microchips. Blocking proteins designed for enzyme-linked immunosorbent assay (ELISA) applications (e.g. Block Ace and UltraBlock), and egg-white lysozyme were proposed in this study. The EOF could be enhanced, suppressed or its direction could be reversed, depending on the buffer pH and the charge on the proteins. The coating procedure is simple, requiring only filling of the microchannels with a coating solution, followed by a rinse with a running buffer solution prior to analysis. One major advantage of this method is that it is not necessary to add the coating agent to the running buffer solution. Block Ace and UltraBlock coatings were stable for at least five runs in a given microchannel without the need to condition the coating between runs other than replenishing the buffer solution after each run, i.e. the RSD values of EOF (n=5) were less than 4.3%, and there was no significant change in the EOF after 5 runs. The reproducibility of the coating procedures was found from the channel-to-channel RSD values of the EOF, and were less than 5.0% when using HEPES-Na buffer (pH 7.4) as the running buffer. Several examples of electrophoretic separations of amino acids and biogenic amines derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) are demonstrated in this paper. The dynamic coating method has the potential for a broad range of applications in microchip capillary electrophoresis (microchip CE) separations.
Collapse
Affiliation(s)
- Nahoko Naruishi
- Human Stress Signal Research Center, HSS, National Institute of Advanced Industrial Science and Technology, AIST, 1-8-31 Midorigaoka, Ikeda, Osaka 563-8577, Japan
| | | | | | | |
Collapse
|
12
|
Yu CJ, Tseng WL. Online concentration and separation of basic proteins using a cationic polyelectrolyte in the presence of reversed electroosmotic flow. Electrophoresis 2006; 27:3569-77. [PMID: 16915567 DOI: 10.1002/elps.200600121] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
We report an online concentration and separation method for basic proteins using poly(diallyldimethylammonium chloride) (PDDA) solutions in the presence of reversed EOF. Using a capillary dynamically coated with 2% PDDA containing 0.1 M NaCl and filled with 1.2% PDDA under neutral conditions (10 mM phosphate, pH 7.0), we have demonstrated the separation of six basic proteins with peak efficiencies ranging from 175 000 to 616 000 plates/m and RSDs of migration time less than 0.4%. Additionally, high-speed separation of six basic proteins (<7 min) was achieved using a short capillary filled with 0.6% PDDA solutions. Under injection of the large-volume sample (210 nL), the LODs at S/N of 3 for basic proteins are down to nanomolar range. For example, the LOD for lysozyme is 1.2 nM, which is a 260-fold sensitivity enhancement compared with conventional injection method. The proposed method has been applied to the stacking of lysozyme in human saliva samples. Without any pretreatment, we also demonstrated the capability of this method to detect low amounts of peptide samples through the stacking of tryptic peptide of myoglobin. The experimental results indicate that our proposed method has great potential for use in clinical diagnosis and proteomics applications.
Collapse
Affiliation(s)
- Cheng-Ju Yu
- Department of Chemistry, National SunYat-sen University, Kaohsiung, Taiwan
| | | |
Collapse
|
13
|
Kato M, Imamura E, Sakai-Kato K, Nakajima T, Toyo'oka T. Cationic amylopectin derivatives as additives for analysis of proteins in capillary electrophoresis. Electrophoresis 2006; 27:1895-9. [PMID: 16607606 DOI: 10.1002/elps.200500429] [Citation(s) in RCA: 17] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Positively charged amylopectin, which is a major constituent of cationic starch, was used to modify the inner surface of fused-silica capillaries by addition to the running solution, which was subsequently employed in CE. Capillaries filled with cationic amylopectin derivatives were shown to generate a stable reversed EOF in the investigated range of pH 4-8. Among the additives studied, quaternary ammonium amylopectin derivatives with high amino and low hydroxypropyl groups showed fast electroosmotic mobility and very effectively suppressed the adsorption of proteins. The run-to-run and batch-to-batch repeatability of the procedures were satisfactory with RSDs of 0.5% and 2.4%, respectively. A basic protein, alpha-chymotrypsinogen, migrated within 6 min and the theoretical plate number of it reached 560 000 plates/m.
Collapse
Affiliation(s)
- Masaru Kato
- Department of Analytical Chemistry, School of Pharmaceutical Sciences and COE Program in the 21st Century, University of Shizuoka, Shizuoka, Japan
| | | | | | | | | |
Collapse
|
14
|
Sakai-Kato K, Kato M, Nakajima T, Toyo'oka T, Imai K, Utsunomiya-Tate N. Cationic starch derivatives as dynamic coating additives for protein analysis in capillary electrophoresis. J Chromatogr A 2006; 1111:127-32. [PMID: 16569570 DOI: 10.1016/j.chroma.2005.06.097] [Citation(s) in RCA: 25] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2005] [Revised: 06/07/2005] [Accepted: 06/14/2005] [Indexed: 11/21/2022]
Abstract
Positively charged starch derivatives were used to modify the inner surface of fused-silica capillaries by addition to running buffer, which were subsequently employed in capillary electrophoresis (CE). Capillaries coated with the cationic starch derivatives were shown to generate a stable, reversed electroosmotic flow (EOF) in the investigated pH range of 3-9. The presented coating procedure was fast, based on a simple rinsing protocol where the polymer created a physically adsorbed, cationic polymer layer. Among the additives studied, a quaternary ammonium starch derivative showed a fast EOF mobility and effectively suppressed the adsorption of proteins. The intra- and inter-day reproducibility of the coating referring to the EOF mobility were satisfactory with relative standard deviation (RSD) of 0.27 and 1.67%, respectively. The coating enabled separation of some protein mixtures including basic proteins within l3 min with efficiencies up to 280,000 plates/m. In addition, this cationic starch derivative possessed a good solubility (about 100mg/mL), and it does not significantly contribute to the background adsorption in the UV region of 190-400 nm.
Collapse
Affiliation(s)
- Kumiko Sakai-Kato
- Research Institute of Pharmaceutical Sciences, Musashino University, Tokyo, Japan.
| | | | | | | | | | | |
Collapse
|
15
|
Bi H, Weng X, Qu H, Kong J, Yang P, Liu B. Strategy for Allosteric Analysis Based on Protein-Patterned Stationary Phase in Microfluidic Chip. J Proteome Res 2005; 4:2154-60. [PMID: 16335962 DOI: 10.1021/pr050240j] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
An effective method is presented for the on-chip analysis of chiral interactions with a successful depression of nonspecific adsorption. The alumina gel-derived protein network on poly(methyl methacrylate) (PMMA) microchannel was explored to form a protein-stationary phase and then used to carry out electrophoresis for fast enantioseparation coupled with electrochemical detection. On the basis of the chemical modification of a synthesized copolymer containing silane-functionalized scaffold, alumina sol-gel could react readily with the silane groups and form steady microstructure on the chip surface achieving the encapsulation of functional biomolecules. Compared with the native PMMA microchannels, the modified surfaces exhibited much better wettability, more stable and enhanced electroosmotic mobility, and less nonspecific adsorption. The water contact angle and EOF of alumina-gel-derived PMMA substrate were 22 degrees and 4.3 x 10(-4) cm(2) V(-1) s(-1), compared to those of 73 degrees and 1.9 x 10(-4) cm(2) V(-1) s(-1) from the untreated one, respectively. Bovine serum albumin, acting as a target protein, could be stably and homogeneously immobilized in the modified PMMA microchannel to fabricate a protein-stationary phase. Under a mild condition, D- and L-tryptophan were efficiently separated with a resolution of 1.57. The as-prepared microchip can perform chiral separations within short time, indicating that the general protocol has the potential to provide a platform for high throughput screening of enantiomer candidates such as those biochemical drugs with protein targets and the research of receptor interactions.
Collapse
Affiliation(s)
- Hongyan Bi
- Department of Chemistry, Research Center for Proteome, Fudan University, Shanghai 200433, People's Republic of China
| | | | | | | | | | | |
Collapse
|
16
|
Kato M, Gyoten Y, Sakai-Kato K, Nakajima T, Toyo'oka T. Analysis of amino acids and proteins using a poly(methyl methacrylate) microfluidic system. Electrophoresis 2005; 26:3682-8. [PMID: 16152664 DOI: 10.1002/elps.200500124] [Citation(s) in RCA: 18] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Plastic microchips are very promising analytical devices for the high-speed analysis of biological compounds. However, due to its hydrophobicity, their surface strongly interacts with nonpolar analytes or species containing hydrophobic domains, resulting in a significant uncontrolled adsorption on the channel walls. This paper describes the migration of fluorescence-labeled amino acids and proteins using the poly(methyl methacrylate) microchip. A cationic starch derivative significantly decreases the adsorption of analytes on the channel walls. The migration time of the analytes was related to their molecular weight and net charge or pI of the analytes. FITC-BSA migrated within 2 min, and the theoretical plate number of the peak reached 480,000 plates/m. Furthermore, proteins with a wide range of pI values and molecular weights migrated within 1 min using the microchip.
Collapse
Affiliation(s)
- Masaru Kato
- Department of Analytical Chemistry, School of Pharmaceutical Sciences and COE Program in the 21st Century, University of Shizuoka, Shizuoka, Japan
| | | | | | | | | |
Collapse
|
17
|
Abad-Villar EM, Kubán P, Hauser PC. Determination of biochemical species on electrophoresis chips with an external contactless conductivity detector. Electrophoresis 2005; 26:3609-14. [PMID: 16152667 DOI: 10.1002/elps.200500149] [Citation(s) in RCA: 51] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Contactless conductivity measurements were found to be suitable for the direct detection, i.e., without needing any labels, of a range of biochemically relevant species, namely amino acids, peptides, proteins, immunoglobulin, and DNA. It was also possible to monitor the products of the enzymatic digestion of HSA with pepsin. Detection was carried out on bare electrophoresis chips made from poly(methyl methacrylate) by probing the conductivity in the channel with a pair of external electrodes, which are fixed on the chip holder. Separation efficiencies up to 15,000 plates could be obtained and LODs are in the low muM-range, except for immunoglobulin G (IgG) which could be determined down to 0.4 nM. Linear dynamic ranges of two to three orders of magnitude were obtained for the peptides as examples.
Collapse
|