1
|
Electrochemiluminescence imaging of latent fingerprints by electropolymerized luminol. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114238] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
2
|
Gao H, Han W, Qi H, Gao Q, Zhang C. Electrochemiluminescence Imaging for the Morphological and Quantitative Analysis of Living Cells under External Stimulation. Anal Chem 2020; 92:8278-8284. [PMID: 32458679 DOI: 10.1021/acs.analchem.0c00528] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
In this work, a simple electrochemiluminescence (ECL) imaging method based on the cell shield of the ECL emission was developed for the morphological and quantitative analysis of living cells under external stimulation. ECL images of MCF-7 cells cultured on or captured at the glassy carbon electrode (GCE) surface in a solution of tris(2,2'-bipyridyl)ruthenium(II)-tri-n-propylamine were recorded. Important morphological characteristics of living cells, including cell shape, cell area, average cell boundary, and junction distance between two adjacent cells, were directly obtained using the developed negative ECL imaging method. The ECL images revealed gradual morphological changes in cells on the GCE surface. During the course of H2O2 stimulation of cells on the GCE surface, cells shrunk, rounded up, disengaged from surrounding cells, and finally detached from the electrode surface. During the course of electrical stimulation (0.8 V), the cells on the GCE surface exhibited aggregation as demonstrated by increases in the average cell boundary and decreases in the junction distance between two adjacent cells. Additionally, a quantitative method for the sensitive determination of MCF-7 cells with a limit of detection of 29 cells/mL was developed using the negative ECL imaging strategy. This work demonstrates that the proposed negative ECL imaging strategy is a promising approach to assess important morphological characteristics of living cells during the course of external stimulation and to obtain quantitative information on cell concentrations in solution.
Collapse
Affiliation(s)
- Hongfang Gao
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Weijuan Han
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Honglan Qi
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Qiang Gao
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| | - Chengxiao Zhang
- Key Laboratory of Analytical Chemistry for Life Science of Shaanxi Province, School of Chemistry and Chemical Engineering, Shaanxi Normal University, Xi'an 710062, China
| |
Collapse
|
3
|
Jiang D, Shen M, Ahiadu B, Rusling JF. Organ-Specific Screening for Protein Damage Using Magnetic Bead Bioreactors and LC-MS/MS. Anal Chem 2020; 92:5337-5345. [PMID: 32176468 PMCID: PMC7509849 DOI: 10.1021/acs.analchem.9b05871] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
A new 96-well plate methodology for fast, enzyme-multiplexed screening for metabolite-protein adducts was developed. Magnetic beads coated with metabolic enzymes were used to make potentially reactive metabolites that can react with test protein in the wells, followed by sample workup in multiple 96-well filter plates for LC-MS/MS analysis. Incorporation of human microsomes from multiple organs and selected supersomes of single cytochrome P450 (cyt P450) enzymes on the magnetic beads provided a broad spectrum of metabolic enzymes. The reacted protein was then isolated, denatured, reduced, alkylated, and digested, and peptides were collected in a sequence of 96-well filter plates for analysis. Method performance was evaluated by trapping acetaminophen reactive metabolite N-acetyl-p-benzoquinoneimine (NAPQI) with human glutathione S-transferase pi (hGSTP), human serum albumin (HSA), and bovine serum albumin (BSA) as model target proteins. Relative amounts of acetaminophen metabolite and hGSTP adducts were compared with 10 different cyt P450 enzymes. Human liver microsomes and CYP1A2 supersomes showed the highest bioactivation rate for adduct formation, in which all four cysteines of hGSTP reacted with NAPQI. Eight cysteines of HSA and four cysteines of BSA have been detected to react with NAPQI. This method has the potential for fast multienzyme protein adduct screening with high efficiency and accuracy.
Collapse
Affiliation(s)
- Di Jiang
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Min Shen
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Ben Ahiadu
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - James F Rusling
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Department of Surgery and Neag Cancer Center, UConn Health, Farmington, Connecticut 06032, United States
- Institute of Material Science, University of Connecticut, Storrs, Connecticut 06269, United States
- School of Chemistry, National University of Ireland at Galway, Galway H91 TK33, Ireland
| |
Collapse
|
4
|
Zhuo Y, Wang HJ, Lei YM, Zhang P, Liu JL, Chai YQ, Yuan R. Electrochemiluminescence biosensing based on different modes of switching signals. Analyst 2018; 143:3230-3248. [DOI: 10.1039/c8an00276b] [Citation(s) in RCA: 31] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Electrochemiluminescence (ECL) has attracted much attention in various fields of analysis owing to low background signals, high sensitivity, and excellent controllability.
Collapse
Affiliation(s)
- Ying Zhuo
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Hai-Jun Wang
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Yan-Mei Lei
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Pu Zhang
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Jia-Li Liu
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Ya-Qin Chai
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| | - Ruo Yuan
- Key Laboratory of Luminescent and Real-Time Analytical Chemistry (Southwest University)
- Ministry of Education
- College of Chemistry and Chemical Engineering
- Southwest University
- Chongqing 400715
| |
Collapse
|
5
|
Bist I, Bhakta S, Jiang D, Keyes TE, Martin A, Forster RJ, Rusling JF. Evaluating Metabolite-Related DNA Oxidation and Adduct Damage from Aryl Amines Using a Microfluidic ECL Array. Anal Chem 2017; 89:12441-12449. [PMID: 29083162 PMCID: PMC5777145 DOI: 10.1021/acs.analchem.7b03528] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
Damage to DNA from the metabolites of drugs and pollutants constitutes a major human toxicity pathway known as genotoxicity. Metabolites can react with metal ions and NADPH to oxidize DNA or participate in SN2 reactions to form covalently linked adducts with DNA bases. Guanines are the main DNA oxidation sites, and 8-oxo-7,8-dihydro-2-deoxyguanosine (8-oxodG) is the initial product. Here we describe a novel electrochemiluminescent (ECL) microwell array that produces metabolites from test compounds and measures relative rates of DNA oxidation and DNA adduct damage. In this new array, films of DNA, metabolic enzymes, and an ECL metallopolymer or complex assembled in microwells on a pyrolytic graphite wafer are housed in dual microfluidic chambers. As reactant solution passes over the wells, metabolites form and can react with DNA in the films to form DNA adducts. These adducts are detected by ECL from a RuPVP polymer that uses DNA as a coreactant. Aryl amines also combine with Cu2+ and NADPH to form reactive oxygen species (ROS) that oxidize DNA. The resulting 8-oxodG was detected selectively by ECL-generating bis(2,2'-bipyridine)-(4-(1,10-phenanthrolin-6-yl)-benzoic acid)Os(II). DNA/enzyme films on magnetic beads were oxidized similarly, and 8-oxodG determined by LC/MS/MS enabled array standardization. The array limit of detection for oxidation was 720 8-oxodG per 106 nucleobases. For a series of aryl amines, metabolite-generated DNA oxidation and adduct formation turnover rates from the array correlated very well with rodent 1/TD50 and Comet assay results.
Collapse
Affiliation(s)
- Itti Bist
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Snehasis Bhakta
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Di Jiang
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Tia E. Keyes
- School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - Aaron Martin
- School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - Robert J. Forster
- School of Chemical Sciences, Dublin City University, Dublin 9, Ireland
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Institute of Materials Science, University of Connecticut, Storrs, Connecticut 06269, United States
- Department of Surgery and Neag Cancer Center, UConn Health, Farmington, Connecticut 06032, United States
- School of Chemistry, National University of Ireland, Galway, University Road, Galway H91 TK33, Ireland
| |
Collapse
|
6
|
Kadimisetty K, Malla S, Rusling JF. Automated 3-D Printed Arrays to Evaluate Genotoxic Chemistry: E-Cigarettes and Water Samples. ACS Sens 2017; 2:670-678. [PMID: 28723166 DOI: 10.1021/acssensors.7b00118] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
Abstract
A novel, automated, low cost, three-dimensional (3-D) printed microfluidic array was developed to detect DNA damage from metabolites of chemicals in environmental samples. The electrochemiluminescent (ECL) detection platform incorporates layer-by-layer (LbL) assembled films of microsomal enzymes, DNA and an ECL-emitting ruthenium metallopolymer in ∼10 nm deep microwells. Liquid samples are introduced into the array, metabolized by the human enzymes, products react with DNA if possible, and DNA damage is detected by ECL with a camera. Measurements of relative DNA damage by the array assess the genotoxic potential of the samples. The array analyzes three samples simultaneously in 5 min. Measurement of cigarette and e-cigarette smoke extracts and polluted water samples was used to establish proof of concept. Potentially genotoxic reactions from e-cigarette vapor similar to smoke from conventional cigarettes were demonstrated. Untreated wastewater showed a high genotoxic potential compared to negligible values for treated wastewater from a pollution control treatment plant. Reactivity of chemicals known to produce high rates of metabolite-related DNA damage were measured, and array results for environmental samples were expressed in terms of equivalent responses from these standards to assess severity of possible DNA damage. Genotoxic assessment of wastewater samples during processing also highlighted future on-site monitoring applications.
Collapse
Affiliation(s)
- Karteek Kadimisetty
- Department
of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Spundana Malla
- Department
of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - James F. Rusling
- Department
of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Institute of Material Science, Storrs, Connecticut 06269, United States
- Department
of Surgery and Neag Cancer Center, UConn Health, Farmington, Connecticut 06032, United States
- School
of Chemistry, National University of Ireland at Galway, Galaway, Ireland
| |
Collapse
|
7
|
Yao C, Song H, Wan Y, Ma K, Zheng C, Cui H, Xin P, Ji X, Deng S. Electro-Photodynamic Visualization of Singlet Oxygen Induced by Zinc Porphyrin Modified Microchip in Aqueous Media. ACS APPLIED MATERIALS & INTERFACES 2016; 8:34833-34843. [PMID: 27762540 DOI: 10.1021/acsami.6b10213] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
A porphyrin-based electro-photodynamic imaging system was fabricated for monitoring the concentration of oxygen. Distinct from the electrochemiluminescent (ECL) inability of numerous organic species in aqueous solutions, a strong and stable red irradiation at 634 nm could be stimulated electrochemically on zinc(II) meso-tetra(4-carboxyphenyl) porphine (ZnTCPP)/tetraoctylammonium bromide (TOAB) in the physiological condition. In terms of in situ electron paramagnetic resonance and ECL spectroscopies, the nature of ECL was thoroughly investigated, being exactly the chemiluminescence from singlet oxygen (1O2) produced during the successive electro-reduction of ZnTCPP. Meanwhile, the excellent film-making capacity of amphiphilic TOAB as a potent ion barrier granted the luminophores a micro-order and patternable electrode modification. Such platform was exceptionally tolerant of pH variation, facilitating a durable solid-state ECL visualization under potentiostatic electrolysis and time exposure in the charge-coupled device (CCD) camera. For flow-injection and real-time detection, a chip-mounted microfluidic cell was customized and manufactured. A sensitive and simple vision-sensing of O2 was further achieved with a real determination limit as low as a few micromolar level. The developed ECL imaging system is a good prototype and an eco-friendly technique in the cathodic range, and thus, it would supplement the primary anodic imaging library, showing great promise for multiplexed and colorimetric assays as well as oxygen-involved activity studies in the future.
Collapse
Affiliation(s)
- Chuanguang Yao
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Hongxin Song
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Ying Wan
- Intelligent Microsystem Technology and Engineering Center, School of Mechanical Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Kefeng Ma
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Chenyu Zheng
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Hongda Cui
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Peng Xin
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Xubo Ji
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
| | - Shengyuan Deng
- School of Environmental and Biological Engineering, Nanjing University of Science and Technology , Nanjing 210094, P.R. China
- Materials Research Science and Engineering Centers (MRSEC), Department of Chemistry, Penn State University , University Park, Pennsylvania 16801, United States
| |
Collapse
|
8
|
Bano K, Rusling JF. Electrochemiluminescence Arrays for Studies of Metabolite-related Toxicity. ELECTROANAL 2016; 28:2636-2643. [PMID: 28592918 DOI: 10.1002/elan.201600207] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
This article reviews recent progress from our laboratory in electrochemiluminescence (ECL) arrays designed for screening toxicity-related chemistry of chemical and drug candidates. Cytochrome P450s and metabolic bioconjugation enzymes convert lipophilic chemicals in our bodies by oxidation and bioconjugation that can lead to toxic metabolites. DNA can be used as an easily measurable toxicity-related endpoint, targeting DNA oxidation and addcut formation with metabolites. ECL using guanosines in the DNA strands as co-reactants have been used in high throughput arrays utilizing DNA-enzyme films fabricated layer-by-layer. This review describes approaches developed to provide new high throughput ECL arrays to aid in toxicity assessment for drug and chemical product development.
Collapse
Affiliation(s)
- Kiran Bano
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA
| | - James F Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA.,Department of Surgery and Neag Cancer Center, University of Connecticut Health Center, Farmington, CT 06032, USA.,Institute of Material Science, University of Connecticut, Storrs, CT 06269, USA.,School of Chemistry, NationalUniversity of Ireland at Galway, Ireland
| |
Collapse
|
9
|
Wasalathanthri DP, Li D, Song D, Zheng Z, Choudhary D, Jansson I, Lu X, Schenkman JB, Rusling JF. Elucidating Organ-Specific Metabolic Toxicity Chemistry from Electrochemiluminescent Enzyme/DNA Arrays and Bioreactor Bead-LC-MS/MS. Chem Sci 2015; 6:2457-2468. [PMID: 25798217 PMCID: PMC4364445 DOI: 10.1039/c4sc03401e] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Accepted: 02/12/2015] [Indexed: 12/15/2022] Open
Abstract
Human toxic responses are very often related to metabolism. Liver metabolism is traditionally studied, but other organs also convert chemicals and drugs to reactive metabolites leading to toxicity. When DNA damage is found, the effects are termed genotoxic. Here we describe a comprehensive new approach to evaluate chemical genotoxicity pathways from metabolites formed in-situ by a broad spectrum of liver, lung, kidney and intestinal enzymes. DNA damage rates are measured with a microfluidic array featuring a 64-nanowell chip to facilitate fabrication of films of DNA, electrochemiluminescent (ECL) detection polymer [Ru(bpy)2(PVP)10]2+ {(PVP = poly(4-vinylpyridine)} and metabolic enzymes. First, multiple enzyme reactions are run on test compounds using the array, then ECL light related to the resulting DNA damage is measured. A companion method next facilitates reaction of target compounds with DNA/enzyme-coated magnetic beads in 96 well plates, after which DNA is hydrolyzed and nucleobase-metabolite adducts are detected by LC-MS/MS. The same organ enzymes are used as in the arrays. Outcomes revealed nucleobase adducts from DNA damage, enzymes responsible for reactive metabolites (e.g. cyt P450s), influence of bioconjugation, relative dynamics of enzymes suites from different organs, and pathways of possible genotoxic chemistry. Correlations between DNA damage rates from the cell-free array and organ-specific cell-based DNA damage were found. Results illustrate the power of the combined DNA/enzyme microarray/LC-MS/MS approach to efficiently explore a broad spectrum of organ-specific metabolic genotoxic pathways for drugs and environmental chemicals.
Collapse
Affiliation(s)
| | - Dandan Li
- Department of Chemistry , University of Connecticut , Storrs , Connecticut 06269 , USA .
| | - Donghui Song
- Department of Pharmaceutical Sciences , University of Connecticut , Storrs , Connecticut 06269 , USA
| | - Zhifang Zheng
- Department of Chemistry , University of Connecticut , Storrs , Connecticut 06269 , USA .
| | - Dharamainder Choudhary
- Department of Surgery , University of Connecticut Health Center , Farmington , Connecticut 06032 , USA
| | - Ingela Jansson
- Department of Cell Biology , University of Connecticut Health Center , Farmington , Connecticut 06032 , USA
| | - Xiuling Lu
- Department of Pharmaceutical Sciences , University of Connecticut , Storrs , Connecticut 06269 , USA
| | - John B. Schenkman
- Department of Cell Biology , University of Connecticut Health Center , Farmington , Connecticut 06032 , USA
| | - James F. Rusling
- Department of Chemistry , University of Connecticut , Storrs , Connecticut 06269 , USA .
- National University of Ireland at Galway , Ireland
- Department of Cell Biology , University of Connecticut Health Center , Farmington , Connecticut 06032 , USA
| |
Collapse
|
10
|
Ding C, Zhang W, Wang W, Chen Y, Li X. Amplification strategies using electrochemiluminescence biosensors for the detection of DNA, bioactive molecules and cancer biomarkers. Trends Analyt Chem 2015. [DOI: 10.1016/j.trac.2014.10.015] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/10/2023]
|
11
|
Lee HS, Chang JH. Antimicrobial spine-bone cement with caffeic acid phenethyl ester for controlled release formulation and in vivo biological assessments. MEDCHEMCOMM 2015. [DOI: 10.1039/c4md00272e] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The work reports the preparation of antimicrobial spine-bone-cement with a highly controlled release formulation that was subjected to tests, involvingin vitroandin vivobiological assessments such as antimicrobial effects, a cytotoxicity test, a bacterial reverse mutation (Ames) assay, a micronucleus assay, and implantation analysis.
Collapse
Affiliation(s)
- Hye Sun Lee
- Korea Institute of Ceramic Engineering and Technology
- Seoul 153-801
- Korea
| | - Jeong Ho Chang
- Korea Institute of Ceramic Engineering and Technology
- Seoul 153-801
- Korea
| |
Collapse
|
12
|
Rusling JF, Wasalathanthri DP, Schenkman JB. Thin multicomponent films for functional enzyme devices and bioreactor particles. SOFT MATTER 2014; 10:8145-8156. [PMID: 25209428 PMCID: PMC4183705 DOI: 10.1039/c4sm01679c] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Complex functional films containing enzymes and other biomolecules are easily fabricated in nm-scale thicknesses by using layer-by-layer (LbL) methodologies first popularized by Lvov and Decher. In this review, we highlight the high level functional capabilities possible with LbL films of biomolecules based on our own research experiences. We first describe the basics of enzyme film fabrication by LbL alternate electrostatic adsorption, then discuss how to make functional enzyme-polyion films of remarkably high stability. Focusing on cytochrome P450s, we discuss films developed to electrochemically activate the natural catalytic cycle of these key metabolic enzymes. We then describe multifunctional, multicomponent DNA/enzyme/polyion films on arrays and particle surfaces for high throughput metabolic toxicity screening using electrochemiluminescence and LC-MS/MS. Using multicomponent LbL films, complex functionality for bioanalytical and biochemical purposes can be achieved that is difficult or impossible using conventional approaches.
Collapse
Affiliation(s)
- James F Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA.
| | | | | |
Collapse
|
13
|
Wasalathanthri DP, Malla S, Bist I, Tang CK, Faria RC, Rusling JF. High-throughput metabolic genotoxicity screening with a fluidic microwell chip and electrochemiluminescence. LAB ON A CHIP 2013; 13:4554-62. [PMID: 24113555 PMCID: PMC3901045 DOI: 10.1039/c3lc50698c] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
A high throughput electrochemiluminescent (ECL) chip was fabricated and integrated into a fluidic system for screening toxicity-related chemistry of drug and pollutant metabolites. The chip base is conductive pyrolytic graphite onto which are printed 64 microwells capable of holding one-μL droplets. Films combining DNA, metabolic enzymes and an ECL-generating ruthenium metallopolymer (Ru(II)PVP) are fabricated in these microwells. The system runs metabolic enzyme reactions, and subsequently detects DNA damage caused by reactive metabolites. The performance of the chip was tested by measuring DNA damage caused by metabolites of the well-known procarcinogen benzo[a]pyrene (B[a]P). Liver microsomes and cytochrome P450 (cyt P450) enzymes were used with and without epoxide hydrolase (EH), a conjugative enzyme required for multi-enzyme bioactivation of B[a]P. DNA adduct formation was confirmed by determining specific DNA-metabolite adducts using similar films of DNA/enzyme on magnetic bead biocolloid reactors, hydrolyzing the DNA, and analyzing by capillary liquid chromatography-mass spectrometry (CapLC-MS/MS). The fluidic chip was also used to measure IC50-values of inhibitors of cyt P450s. All results show good correlation with reported enzyme activity and inhibition assays.
Collapse
|
14
|
Pan S, Li D, Zhao L, Schenkman JB, Rusling JF. Genotoxicity-related chemistry of human metabolites of benzo[ghi]perylene (B[ghi]P) investigated using electro-optical arrays and DNA/microsome biocolloid reactors with LC-MS/MS. Chem Res Toxicol 2013; 26:1229-39. [PMID: 23879290 PMCID: PMC3763812 DOI: 10.1021/tx400147c] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
Abstract
There is limited and sometimes contradictory information about the genotoxicity of the polycyclic aromatic hydrocarbon benzo[ghi]perylene (B[ghi]P). Using recently developed metabolic toxicity screening arrays and a biocolloid reactor-LC-MS/MS approach, both featuring films of DNA and human metabolic enzymes, we demonstrated the relatively low reactivity of metabolically activated B[ghi]P toward DNA. Electro-optical toxicity screening arrays showed that B[ghi]P metabolites damage DNA at a 3-fold lower rate than benzo[a]pyrene (B[a]P), whose metabolites have a strong and well-understood propensity for DNA damage. Metabolic studies using magnetic bead biocolloid reactors coated with microsomal enzymes in 96-well plates showed that cyt P450s 1A1 and 1B1 provide high activity for B[ghi]P and B[a]P conversion. Consistent with published results, the major metabolism of B[ghi]P involved oxidations at 3,4 and 11,12 positions, leading to the formation of B[ghi]P 3,4-oxide and B[ghi]P 3,4,11,12-bisoxide. B[ghi]P 3,4-oxide was synthesized and reacted with deoxyadenosine at N6 and N7 positions and with deoxyguanosine at the N2 position. B[ghi]P 3,4-oxide is hydrolytically unstable and transforms into the 3,4-diol or converts to 3- or 4-hydroxy B[ghi]P. LC-MS/MS of reaction products from the magnetic biocolloid reactor particles coated with DNA and human enzymes revealed for the first time that a major DNA adduct results from the reaction between B[ghi]P 3,4,11,12-bisoxide and deoxyguanosine. Results also demonstrated 5-fold lower formation rates of the major DNA adduct for B[ghi]P metabolites compared to B[a]P. Overall, results from both the electro-optical array and biocolloid reactor-LC-MS/MS consistently suggest a lower human genotoxicity profile of B[ghi]P than B[a]P.
Collapse
Affiliation(s)
- Shenmin Pan
- Department of Chemistry, University of Connecticut, Storrs, CT 06269
| | - Dandan Li
- Department of Chemistry, University of Connecticut, Storrs, CT 06269
| | - Linlin Zhao
- Department of Chemistry, University of Connecticut, Storrs, CT 06269
| | - John B. Schenkman
- Department of Cell Biology, University of Connecticut Health Center, Farmington, CT 06032
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT 06269
- Department of Cell Biology, University of Connecticut Health Center, Farmington, CT 06032
| |
Collapse
|
15
|
Wei W, Zhang DM, Yin LH, Pu YP, Liu SQ. Colorimetric detection of DNA damage by using hemin-graphene nanocomposites. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2013; 106:163-169. [PMID: 23376271 DOI: 10.1016/j.saa.2012.12.091] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/26/2012] [Revised: 12/20/2012] [Accepted: 12/30/2012] [Indexed: 06/01/2023]
Abstract
A colorimetric method for detection of DNA damage was developed by using hemin-graphene nanosheets (H-GNs). H-GNs were skillfully synthesized by adsorping of hemin on graphene through π-π interactions. The as-prepared H-GNs possessed both the ability of graphene to differentiate the damage DNA from intact DNA and the catalytic action of hemin. The damaged DNA made H-GNs coagulated to different degrees from the intact DNA because there were different amount of negative charge exposed on their surface, which made a great impact on the solubility of H-GNs. As a result, the corresponding centrifugal supernatant of H-GNs solution showed different color in the presence of 3,3',5,5'-tetramethylbenzidine (TMB) and H2O2, which could be discriminated by naked eyes or by ultraviolet (UV)-visible spectrometer. Based on this, the damaged effects of styrene oxide (SO), NaAsO2 and UV radiation on DNA were studied. Results showed that SO exerted most serious damage effect on DNA although all of them damaged DNA seriously. The new method for detection of DNA damage showed good prospect in the evaluation of genotoxicity of new compounds, the maximum limit of pesticide residue, food additives, and so on, which is important in the fields of food science, pharmaceutical science and pesticide science.
Collapse
Affiliation(s)
- W Wei
- Key Laboratory of Environmental Medicine Engineering, Ministry of Education, School of Chemistry and Chemical Engineering, Southeast University, Nanjing 211189, Jiangsu Province, PR China
| | | | | | | | | |
Collapse
|
16
|
Mani V, Kadimisetty K, Malla S, Joshi AA, Rusling JF. Paper-based electrochemiluminescent screening for genotoxic activity in the environment. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2013; 47:1937-44. [PMID: 23331021 PMCID: PMC3578158 DOI: 10.1021/es304426j] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
A low cost, microfluidic paper electrochemical device (μPED) was fabricated using screen printing of electrodes and heat transfer of patterned wax paper onto filter paper. The μPED features films of a light-emitting ruthenium metallopolymer, microsomal metabolic enzymes, and DNA to detect potential genotoxic pollutant activity in environmental samples. Unlike conventional analytical methods that detect specific pollutant compounds, the μPED was designed to rapidly measure the presence of genotoxic equivalents in environmental samples with the signal related to benzo[a]pyrene (B[a]P) as a reference standard. The analytical end point is the detection of DNA damage from metabolites produced in the device using an electrochemiluminescence output measured with a charge-coupled device (CCD) camera. Proof-of-concept of this measurement was established for smoke, water, and food samples. The μPED provides a rapid screening tool for on-site environmental monitoring that specifically monitors the genotoxic reactivity of metabolites of toxic compounds present in the samples.
Collapse
Affiliation(s)
- Vigneshwaran Mani
- Department of Chemistry, University of Connecticut, Storrs, CT, USA 06269
| | | | - Spundana Malla
- Department of Chemistry, University of Connecticut, Storrs, CT, USA 06269
| | - Amit A. Joshi
- Department of Chemistry, University of Connecticut, Storrs, CT, USA 06269
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, CT, USA 06269
- Department of Cell Biology, University of Connecticut Health Center, Farmington, CT, USA 06032
- School of Chemistry, National University of Ireland, Galway
| |
Collapse
|
17
|
Wasalathanthri DP, Faria RC, Malla S, Joshi AA, Schenkman JB, Rusling JF. Screening reactive metabolites bioactivated by multiple enzyme pathways using a multiplexed microfluidic system. Analyst 2013; 138:171-8. [PMID: 23095952 PMCID: PMC3509269 DOI: 10.1039/c2an35993f] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/02/2023]
Abstract
A multiplexed, microfluidic platform to detect reactive metabolites is described, and its performance is illustrated for compounds metabolized by oxidative and bioconjugation enzymes in multi-enzyme pathways to mimic natural human drug metabolism. The device features four 8-electrode screen printed carbon arrays coated with thin films of DNA, a ruthenium-polyvinylpyridine (RuPVP) catalyst, and multiple enzyme sources including human liver microsomes (HLM), cytochrome P450 (cyt P450) 1B1 supersomes, microsomal epoxide hydrolase (EH), human S9 liver fractions (Hs9) and N-acetyltransferase (NAT). Arrays are arranged in parallel to facilitate multiple compound screening, enabling up to 32 enzyme reactions and measurements in 20-30 min. In the first step of the assay, metabolic reactions are achieved under constant flow of oxygenated reactant solutions by electrode driven natural catalytic cycles of cyt P450s and cofactor-supported bioconjugation enzymes. Reactive metabolites formed in the enzyme reactions can react with DNA. Relative DNA damage is measured in the second assay step using square wave voltammetry (SWV) with RuPVP as catalyst. Studies were done on chemicals known to require metabolic activation to induce genotoxicity, and results reproduced known features of metabolite DNA-reactivity for the test compounds. Metabolism of benzo[a]pyrene (B[a]P) by cyt P450s and epoxide hydrolase showed an enhanced relative DNA damage rate for DNA compared to cyt P450s alone. DNA damage rates for arylamines by pathways featuring both oxidative and conjugative enzymes at pH 7.4 gave better correlation with rodent genotoxicity metric TD(50). Results illustrate the broad utility of the reactive metabolite screening device.
Collapse
Affiliation(s)
| | - Ronaldo C. Faria
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Departamento de Química, Universidade Federal de São Carlos, São Carlos, SP, Brazil
| | - Spundana Malla
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - Amit A. Joshi
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
| | - John B. Schenkman
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032, United States
| | - James F. Rusling
- Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269, United States
- Departamento de Química, Universidade Federal de São Carlos, São Carlos, SP, Brazil
- NationalUniversity of Ireland at Galway, Ireland
- Department of Cell Biology, University of Connecticut Health Center, Farmington, Connecticut 06032, United States
| |
Collapse
|
18
|
Deng S, Ju H. Electrogenerated chemiluminescence of nanomaterials for bioanalysis. Analyst 2013; 138:43-61. [DOI: 10.1039/c2an36122a] [Citation(s) in RCA: 172] [Impact Index Per Article: 14.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
19
|
Lee HS, Lee SY, Park SH, Lee JH, Ahn SK, Choi YM, Choi DJ, Chang JH. Antimicrobial medical sutures with caffeic acid phenethyl ester and their in vitro/in vivo biological assessment. MEDCHEMCOMM 2013. [DOI: 10.1039/c2md20289a] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
|
20
|
Zhou J, Lu Q, Tong Y, Wei W, Liu S. Detection of DNA damage by using hairpin molecular beacon probes and graphene oxide. Talanta 2012; 99:625-30. [DOI: 10.1016/j.talanta.2012.06.049] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2012] [Revised: 06/12/2012] [Accepted: 06/20/2012] [Indexed: 11/25/2022]
|
21
|
Xu L, Li Y, Wu S, Liu X, Su B. Imaging latent fingerprints by electrochemiluminescence. Angew Chem Int Ed Engl 2012; 51:8068-72. [PMID: 22865566 DOI: 10.1002/anie.201203815] [Citation(s) in RCA: 153] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2012] [Indexed: 11/06/2022]
Affiliation(s)
- Linru Xu
- Institute of Microanalytical Systems, Department of Chemistry, Zhejiang University, Hangzhou 310058, China
| | | | | | | | | |
Collapse
|
22
|
Xu L, Li Y, Wu S, Liu X, Su B. Imaging Latent Fingerprints by Electrochemiluminescence. Angew Chem Int Ed Engl 2012. [DOI: 10.1002/ange.201203815] [Citation(s) in RCA: 54] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
23
|
Wasalathanthri DP, Mani V, Tang CK, Rusling JF. Microfluidic electrochemical array for detection of reactive metabolites formed by cytochrome P450 enzymes. Anal Chem 2011; 83:9499-506. [PMID: 22040095 DOI: 10.1021/ac202269t] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
A novel, simple, rapid microfluidic array using bioelectronically driven cytochrome P450 enzyme catalysis for reactive metabolite screening is reported for the first time. The device incorporates an eight-electrode screen-printed carbon array coated with thin films of DNA, [Ru(bpy)(2)(PVP)(10)](ClO(4)) {RuPVP}, and rat liver microsomes (RLM) as enzyme sources. Catalysis features electron donation to cyt P450 reductase in the RLMs and subsequent cyt P450 reduction while flowing an oxygenated substrate solution past sensor electrodes. Metabolites react with DNA in the film if they are able, and damaged DNA is detected by catalytic square wave voltammetry (SWV) utilizing the RuPVP polymer. The microfluidic device was tested for a set of common pollutants known to form DNA-reactive metabolites. Logarithmic turnover rates based on SWV responses gave excellent correlation with the rodent liver TD(50) toxicity metric, supporting the utility of the device for toxicity screening. The microfluidic array gave much better S/N and reproducibility than single-electrode sensors based on similar principles.
Collapse
|
24
|
Sardesai NP, Barron JC, Rusling JF. Carbon nanotube microwell array for sensitive electrochemiluminescent detection of cancer biomarker proteins. Anal Chem 2011; 83:6698-703. [PMID: 21728322 DOI: 10.1021/ac201292q] [Citation(s) in RCA: 168] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
This paper describes fabrication of a novel electrochemiluminescence (ECL) immunosensor array featuring capture-antibody-decorated single-wall carbon nanotube (SWCNT) forests residing in the bottoms of 10-μL wells with hydrophobic polymer walls. Silica nanoparticles containing [Ru(bpy)(3)](2+) and secondary antibodies (RuBPY-silica-Ab(2)) are employed in this system for highly sensitive two-analyte detection. Antibodies to prostate specific antigen (PSA) and interleukin-6 (IL-6) were attached to the same RuBPY-silica-Ab(2) particle. The array was fabricated by forming the wells on a conductive pyrolytic graphite chip (1 in. × 1 in.) with a single connection to a potentiostat to achieve ECL. The sandwich immunoassay protocol employs antibodies attached to SWCNTs in the wells to capture analyte proteins. Then RuBPY-silica-Ab(2) is added to bind to the captured proteins. ECL is initiated in the microwells by electrochemical oxidation of tripropyl amine (TprA), which generates excited state [Ru(bpy)(3)](2+) in the 100-nm particles, and is measured with a charge-coupled device (CCD) camera. Separation of the analytical spots by the hydrophobic wall barriers enabled simultaneous immunoassays for two proteins in a single sample without cross-contamination. The detection limit (DL) for PSA was 1 pg mL(-1) and for IL-6 was 0.25 pg mL(-1) (IL-6) in serum. Array determinations of PSA and IL-6 in patient serum were well-correlated with single-protein ELISAs. These microwell SWCNT immunoarrays provide a simple, sensitive approach to the detection of two or more proteins.
Collapse
Affiliation(s)
- Naimish P Sardesai
- Department of Chemistry (U-3060), University of Connecticut, 55 North Eagleville Road, Storrs, Connecticut 06269, USA
| | | | | |
Collapse
|
25
|
Milutinovic M, Suraniti E, Studer V, Mano N, Manojlovic D, Sojic N. Photopatterning of ultrathin electrochemiluminescent redox hydrogel films. Chem Commun (Camb) 2011; 47:9125-7. [DOI: 10.1039/c1cc12724a] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|